- ; M7NH.ASM NorthStar Horizon with HSIO-4 overlay for MDM7xx - 11/11/83
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ; Use the MDM7xx "SET" command to change the baudrate when desired. It
- ; starts out at 300 baud when the program is first called up.
- ;
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ; A>DDT MDM7xx.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4300 0100
- ; -IM7NH-1.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4300 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 66 MDM7xx.COM (now have a modified .COM file)
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 11/11/83 - Renamed to M7NH-1.ASM, no changes - Irv Hoff
- ; 09/11/83 - Changed M712HZ.ASM TO M712NS.ASM - Robert Lehman
- ; - Irv Hoff
- ; = = = = = = = = = = = = = = = = =
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- PORT: EQU 10H ;Port A on HSIO-4
- BAUDRP: EQU PORT
- MODDATP: EQU PORT+2 ;data port for N*HOR
- MODCTL1: EQU PORT+3 ;status port for N*HOR
- MODRCVB: EQU 2 ;bit to test for received data
- MODRCVR: EQU 2 ;modem receive ready
- MODSNDB: EQU 1 ;bit to test for ready to send
- MODSNDR: EQU 1 ;modem send ready bit
- ;
- ;
- ; The HSIO-4 board uses the 8251
- ;
- ;
- ORG 100H
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-Hayes 104H
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB YES ;yes=user-added Setup routine 10BH
- SCRNTEST: DB YES ;Cursor control routine 10CH
- ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
- ;no=resend a record after a valid NAK
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVBKSP: DB NO ;yes=convert backspace to rub 111H
- TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB YES ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB YES ;yes=do not overwrite CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
- NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
- LOGCHR: DB 'L'-40H ;^L = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
- UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 125H
- EXTCHR: DB '^'-40H ;^^ = Send next character 126H
- ;
- ;
- DS 2 ; 128H
- ;
- IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
- DS 7
- OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
- DS 7
- IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
- DS 31
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER: DS 3 ; 192H
- ;
- ;
- CLREOS: CALL JMP$ILPRT ; 195H
- DB ESC,079H,0,0,0 ; 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ; 19EH
- DB 1AH,0,0,0,0 ;clear entire screen 1A1H
- RET ; 1A6H
- ;
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 'Version for NorthStar Horizon / HSIO-4 Port A'
- DB CR,LF,0
- DB RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0C00H (2659 bytes available) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; YOU CAN PUT IN A MESSAGE AT THIS LOCATION WHICH CAN BE CALLED UP WITH
- ; CTL-O IF TRANLOGON HAS BEEN SET YES. YOU CAN PUT IN SEVERAL LINES IF
- ; DESIRED. END WITH A 0.
- ;
- LOGON: DB 'Hello from a NorthStar Horizon computer',CR,LF,0
- ;.....
- ;
- ;
- ; THIS ROUTINE ALLOWS A 300 MS. BREAK TONE TO BE SEND TO RESET SOME
- ; TIME-SHARE COMPUTERS.
- ;
- SENDBRK: MVI A,08H ;send a break tone for 300 ms.
- JMP GOODBYE1
- ;.....
- ;
- ;
- ; THIS ROUTINE SENDS A 300 MS. BREAK TONE AND SETS DTR LOW FOR THE SAME
- ; LENGTH OF TIME TO DISCONNECT SOME MODEMS SUCH AS THE BELL 212A, ETC.
- ;
- GOODBYE: MVI A,0AH ;set break, dtr low
- ;
- GOODBYE1: OUT MODCTL1 ;put command register out of mode
- IN MODCTL1 ;make sure it is now clear
- IN MODCTL1 ;try once more
- MVI B,3 ;delay for 300 ms.
- CALL JMP$TIMER
- MVI A,37H ;reset rts, flags, dtr low, enable r/t
- OUT MODCTL1 ;send to command register
- IN MODCTL1 ;clear any incoming chars.
- IN MODCTL1 ;try once more
- XRA A ;clear the 'A' reg.
- RET
- ;.....
- ;
- ;
- ; THE FOLLOWING ARE USED IN SETTING UP THE HSIO-4 I/O PORT A.
- ;
- INITMOD: MVI A,1 ;default transfer time to 300 baud
- STA MSPEED
- XRA A ;set rts, flags, dtr, disable r/t
- OUT MODCTL1 ;put command register out of mode
- IN MODCTL1 ;make sure it is now clear
- IN MODCTL1 ;try once more
- MVI A,0AAH
- OUT MODCTL1
- MVI A,40H
- OUT MODCTL1
- MVI A,4EH ;1 stop, no parity, 8 bits, 16x asynch
- OUT MODCTL1 ;send to mode register 1
- ;
- INITMOD1: MVI A,06H ;start with 300 baud, internal 4 clock
- OUT BAUDRP ;send to baud rate port
- MVI A,37H ;reset rts, flags, dtr low, enable r/t
- OUT MODCTL1 ;send to command register
- IN MODCTL1 ;clear any incoming chars.
- IN MODCTL1 ;try once more
- XRA A ;clear the 'A' reg.
- RET
- ;.....
- ;
- ;
- ; THE FOLLOWING CHANGES THE BAUD RATE WITH THE SET COMMAND.
- ;
- SETUPR: LXI D,BAUDBUF
- CALL JMP$ILPRT
- DB 'Input Baud Rate (110, 300, 1200, 9600): ',0
- CALL JMP$INBUF
- LXI D,BAUDBUF+2
- CALL JMP$INLNCOMP
- DB '110',0
- JNC OK110
- CALL JMP$INLNCOMP ;compare baudbuf+2 with characters below
- DB '300',0
- JNC OK300 ;go if got match
- CALL JMP$INLNCOMP
- DB '1200',0
- JNC OK1200
- CALL JMP$INLNCOMP
- DB '9600',0
- JNC OK9600
- CALL JMP$ILPRT ;all matches failed, ask again
- DB '++ Incorrect entry ++',CR,LF,BELL,0
- JMP SETUPR ;try again
- ;
- OK110: MVI A,0 ;mspeed 110 baud value
- LHLD BD110 ;get 110 baud parameters in 'HL'
- JMP LOADBD ;go load them
- ;
- OK300: MVI A,1
- LHLD BD300
- JMP LOADBD
- ;
- OK1200: MVI A,5
- LHLD BD1200
- JMP LOADBD
- ;
- OK9600: MVI A,8
- LHLD BD9600
- ;
- LOADBD: STA INITMOD+1
- MOV A,L ;get least significant baud rate byte
- STA INITMOD1+1 ;store in initmod1
- JMP INITMOD ;reset n*hor hsio-4 port a
- ;.....
- ;
- ;
- ; TABLE OF BAUDRATE PARAMETERS FOR HSIO-4 BOARD I/O
- ;
- BD110: DW 0007H
- BD300: DW 0006H
- BD1200: DW 0004H
- BD9600: DW 0001H
- ;
- BAUDBUF: DB 10,0
- DS 10
- ;
- ;-----------------------------------------------------------------------
- ;
- ; THE FOLLOWING ROUTINE COULD BE USED TO DISPLAY SELECTIONS OF INTEREST
- ; TO OWNERS OF THIS COMPUTER. IF USING THE HAYES SMARTMODEM THIS IS
- ; UNAVAILABLE WITHOUT A SPECIAL CHANGE.
- ;
- SPCLMENU: RET
- ;
- ;-----------------------------------------------------------------------
- ;
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0400H (WITH SMARTMODEM)
- ; 0C00H (WITHOUT SMARTMODEM)
- ;
- END
- ;
- 110 ;get 110 baud parameters in 'HL'
- JMP LOADBD ;go load them
- ;
- OK300: MVI A,1
-