home *** CD-ROM | disk | FTP | other *** search
-
- ;======================================================================
- ; M7SG-1.ASM -- Systems Group System 2800 overlay file for MDM700.COM
- ;======================================================================
- ;
- ; Set up for CPC-2810 controller port C (28h). See alternate equate.
- ;
- ; Adapted 12/30/84 by Dave McCrady, Edmonton RCP/M. For use with
- ; MODM700. It may work with earlier versions of MODEM7, but has not
- ; been tested with any.
- ;
- ; You will want to look this file over carefully. There are a number of
- ; options that you can use to configure the program to suit your taste.
- ; This file adapts the Systems 2800 computer to the modem program. Much
- ; of the information contained here is not in the MDM7xx.ASM file.
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ; Use the "SET" command to change the baudrate when desired. It starts
- ; out at 300 baud when the program is first called up. See comments at
- ; the label INITMOD1: and INITMOD2: to change this to 1200 baud default
- ; start-up if desired.
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ; A>DDT MODM700.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4A00 0100
- ; -IM7SG-1.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4A00 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 73 MODM700.COM (now have a modified .COM file)
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; Revisions/changes:
- ;
- ; 12/30/84 -- Adapted from Kaypro overlay (M7KP-2.ASM) -- Dave McCrady
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- ;Comment out the port you don't want ... (same CTC counter is
- ;used for both)
- ;
- PORT: EQU 28H ;Systems Group serial port C
- ;PORT: EQU 2AH ;Systems Group serial port D
- ;
- MODCTL1: EQU PORT+1 ;Modem control port
- MODDATP: EQU PORT ;Modem data port
- MODCTL2: EQU PORT+1 ;Modem control port
- MODRCVB: EQU 01H ;Your bit to test for receive
- MODRCVR: EQU 01H ;Your value when receive ready
- MODSNDB: EQU 04H ;Your bit to test for send
- MODSNDR: EQU 04H ;Your value when send ready
- ;
- ;
- ORG 100H
- ;
- ;
- ; Change the clock speed as needed for your system.
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- SMARTMODEM: DB yes ;yes=HAYES Smartmodem, no=non-PMMI 104H
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 20 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 3 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB YES ;yes=user-added Setup routine 10BH
- SCRNTEST: DB YES ;Cursor control routine 10CH
- ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
- ;no=resend a record after a valid NAK
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVBKSP: DB NO ;yes=convert backspace to rub 111H
- TOGGLEBK: DB NO ;yes=allow toggling of bksp to rub 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB YES ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB YES ;yes=do not overwrite CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=chcks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
- NOCXNNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
- LOGCHR: DB 'L'-40H ;^L = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
- UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
- EXTCHR: DB '^'-40H ;^^ = Send next character 127H
- ;
- ;
- DS 2 ; 128H
- ;
- IN$MODCTL1: MVI A,10H ;channel 0, reset interrupts. 12AH
- OUT MODCTL1
- IN MODCTL1 ;get the status bits
- RET
- DS 3
- ;
- OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
- DS 7
- IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
- DS 7
- ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
- CPI$MODRCVR: CPI MODRCVR ! RET ;value of receive bit when rdy 14BH
- ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
- CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
- DS 6
- ;
- OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port 15AH
- OUT$MODCTL2: OUT MODCTL2 ! RET ;out modem status port 15DH
- ;
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER: DS 3 ; 192H
- ;
- ;
- ; Clear sequences -- CLREOS is clear to end of screen, CLRSCRN is clear
- ; entire screen. Last entry must be 0. Any other 0's act as NOP's.
- ;
- CLREOS: CALL JMP$ILPRT ;Heath/Zenith 19 195H
- DB 01BH,'J',0,0,0 ; 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ;Heath/Zenith 19 19EH
- DB 01BH,'E',0,0,0 ; 1A1H
- RET ; 1A6H
- ;
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 'Version for Systems Group '
- db 'CPC-2810 controller, serial port C'
- db cr,lf,lf
- db 'Initial baud rate set for 300'
- DB CR,LF,0
- RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0380H (473 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0B80H (2521 bytes) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; CTL-O if TRANLOGON has been set YES. You can put in several lines if
- ; desired. End with a 0.
- ;
- ; For members using the PRO-COM DATABASE, fill in the appropriate
- ; firstname;lastname;user id# be sure to end it with CR,0
- ;
- LOGON: DB 'This is a Systems Group System 2800',CR,0
- ;.....
- ;
- ;
- ; This routine allows a 300 ms. break tone to be sent to reset some
- ; time-share computers.
- ;
- SENDBRK: MVI A,5
- OUT MODCTL1
- MVI A,0F8H ;SEND A BREAK TONE
- JMP GOODBYE1
- ;.....
- ;
- ;
- ; This routine sends a 300 ms. break tone and sets DTR low for the same
- ; length of time to disconnect some modems such as the Bell 212A, etc.
- ;
- GOODBYE: MVI A,5
- OUT MODCTL1 ;SEND TO THE STATUS PORT
- MVI A,68H ;TURN OFF DTR
- ;
- GOODBYE1: OUT MODCTL1
- MVI B,3 ;DELAY 300 MS.
- CALL JMP$TIMER
- MVI A,5
- OUT MODCTL1
- MVI A,0E8H ;RESTORE TO NORMAL, 8 BITS, DTR ON, ETC.
- OUT MODCTL1
- RET
- ;.....
- ;
- ;
- ; Systems Group initialization -- sets CTC timer 2EH for send and receive
- ; baudrate.
- ;
- ;
- INITMOD: MVI A,2EH ;SELECT REG.
- OUT MODCTL1
- MVI A,18H ;THROW OUT OF MODE
- OUT MODCTL1
- MVI A,04H ;SELECT REG.
- OUT MODCTL1
- MVI A,44H ;SET ASCII PARAMETERS
- OUT MODCTL1
- MVI A,03H ;SELECT REG.
- OUT MODCTL1
- MVI A,0C1H ;ENABLE RECEIVE
- OUT MODCTL1
- MVI A,05H ;SELECT REG.
- OUT MODCTL1
- MVI A,0EAH ;ENABLE SEND, DTR, RTS
- OUT MODCTL1
- ;
- ; If you desire MDM7xx to start at 1200 baud rather than 300, change
- ; the MVI A,1 to MVI A,5
- ;
- INITMOD1: MVI A,1 ;SET FILE TRANSFER TIME
- STA MSPEED
- MVI A,47H
- OUT 2EH ;SEND TO 'CTC' TIMER
- ;
- ;
- ; Also change this MVI A,80H to MVI A,20H for 1200 baud default
- ;
- INITMOD2: MVI A,80H ;INITIALIZE TO 300 BAUD
- OUT 2EH ;SEND TO 'CTC' TIMER
- RET
- ;.....
- ;
- ;
- ; Sets the modem speed via the SET command.
- ;
- SETUPR: LXI D,BAUDBUF ;POINT TO NEW INPUT BUFFER
- CALL JMP$ILPRT
- DB 'Input Baud Rate (300, 600, 1200, 2400, 4800, 9600): ',0
- CALL JMP$INBUF
- LXI D,BAUDBUF+2
- CALL JMP$INLNCOMP ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW
- DB '300',0
- JNC OK300 ;GO IF GOT MATCH
- CALL JMP$INLNCOMP
- DB '600',0
- JNC OK600
- CALL JMP$INLNCOMP
- DB '1200',0
- JNC OK1200
- CALL JMP$INLNCOMP
- DB '2400',0
- JNC OK2400
- CALL JMP$INLNCOMP
- DB '4800',0
- JNC OK4800
- CALL JMP$INLNCOMP
- DB '9600',0
- JNC OK9600
- CALL JMP$ILPRT ;ALL MATCHES FAILED, TELL OPERATOR
- DB '++ Incorrect entry ++',CR,LF,BELL,0
- JMP SETUPR ;TRY AGAIN
- ;
- OK300: MVI A,1
- LHLD BD300
- JMP LOADBD
- ;
- OK600: MVI A,3
- LHLD BD600
- JMP LOADBD
- ;
- OK1200: MVI A,5
- LHLD BD1200
- JMP LOADBD
- ;
- OK2400: MVI A,6
- LHLD BD2400
- JMP LOADBD
- ;
- OK4800: MVI A,7
- LHLD BD4800
- JMP LOADBD
- ;
- OK9600: MVI A,8
- LHLD BD9600
- ;
- LOADBD: STA INITMOD1+1 ;CHANGE TIME-TO-SEND TO MATCH BAUDRATE
- MOV A,L ;GET BAUDRATE BYTE
- STA INITMOD2+1 ;SEND TO 'CTC' FOR NEW BAUDRATE
- JMP INITMOD1 ;REINITIALIZE TO NEW BAUDRATE, THEN DONE
- ;
- ;
- ; TABLE OF BAUDRATE PARAMETERS
- ;
- BD300: DW 80h
- BD600: DW 40h
- BD1200: DW 20h
- BD2400: DW 10h
- BD4800: DW 08h
- BD9600: DW 04h
- ;
- BAUDBUF: DB 10,0
- DS 10
- ;
- ;-----------------------------------------------------------------------
- ;
- ; The following routine can be used as an auxiliary menu for notes of
- ; interest to a particular computer, etc. If using the Hayes Smartmodem
- ; this is unavailable without a spcial address change.
- ;
- SPCLMENU: RET
- ;
- ;-----------------------------------------------------------------------
- ;
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0380H (with Smartmodem)
- ; 0B80H (without Smartmodem)
- ;
- END
- ;
-