- ; M7NC-1.ASM -- NCR DECISION MATE V overlay for MDM7xx. 07/01/84
- ;
- ; You will want to look this file over carefully. There are a number of
- ; options that you can use to configure the program to suit your taste.
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ; Use the MDM7xx "SET" command to change the baudrate when desired. It
- ; starts out at 300 baud when the program is first called up.
- ;
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ;=============================================================================
- ;
- ;NOTE: The use of the MDMLNK.COM utility makes the following process much
- ; simpler. You may want to use MDMLNK if it is available to you.
- ;
- ;=============================================================================
- ;
- ; A>DDT MDM7xx.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4A00 0100
- ; -IM7xx-x.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4A00 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 07/01/84 - Slight changes for MDM740 - Robert Flagg
- ; Renamed from M7DMV.ASM to avoid
- ; confusion with the Dynabyte Monarch
- ; overlay (M7DM-1.ASM)
- ; 05/30/84 - Renamed to M7DMV.ASM for use with
- ; NCR DMV - Mark Stamos
- ; 11/11/83 - Renamed to M7HZ-1.ASM, no changes - Irv Hoff
- ; 07/27/83 - Renamed to work with MDM712 - Irv Hoff
- ; 02/17/83 - Modified MDM703CF to work with
- ; Heath/Zenith -100 series com-
- ; puters with 2661B I/O - Irv Hoff
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- MODDAT: EQU 070H ;data port for NCR DMV
- MODSTAT: EQU 071H ;STATUS PORT
- MODMODE: EQU 072H ;MODE REGISTER PORT
- MODCMD: EQU 073H ;COMMAND PORT
- WRITE: EQU 004H ;ADDED TO PORT ADDR FOR WRITE
- MODRCVB: EQU 2 ;BIT TO TEST FOR INPUT DATA
- MODRCVR: EQU 2 ;modem receive ready
- MODSNDB: EQU 1 ;bit to test for ready to send
- MODSNDR: EQU 1 ;modem send ready bit
- ;
- ;
- ORG 100H
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- AUTODIAL: DB NO ;yes=HAYES-type modem 104H
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 20 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 0 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 0 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB YES ;yes=user-added Setup routine 10BH
- SCRNTEST: DB YES ;Cursor control routine 10CH
- RETRY: DB NO ;yes=reset the error limit to try again 10DH
- ;no=abort after 10 consecutive errors
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVRUB: DB YES ;yes=rub to backspace 111H
- TOGGLERUB: DB YES ;yes=allow toggling rub to backspace 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB NO ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB YES ;yes=do not overwrite CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
- NOCONNCT: DB 'L'-40H ;^L = Disconnect from the phone line 121H
- LOGCHR: DB 'N'-40H ;^N = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = TOGGLE PRINTER 123H
- UNSAVE: DB 'R'-40H ;^R = close text buffer 124h
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 125H
- EXTCHR: DB '^'-40H ;^^ = Send next character 126H
- ;
- ;
- DS 2 ; 128H
- ;
- IN$MODCTL1: IN MODSTAT ! RET ;in modem control port 12AH
- DS 7
- OUT$MODDATP: OUT MODDAT+4! RET ;out modem data port 134H
- DS 7
- IN$MODDATP: IN MODDAT ! RET ;in modem data port 13EH
- DS 31
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER: DS 3 ; 192H
- ;
- ;
- CLREOS: CALL JMP$ILPRT ; 195H
- DB ESC,'Y',0,0,0 ; 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ; 19EH
- DB ESC,':',0,0,0 ;CLEAR ENTIRE SCREEN 1A1H
- RET ; 1A6H
- ;
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 0BH,CR
- DB 'Version for NCR Decision Mate V with K211 interface'
- DB CR,LF,0
- DB RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0C00H (2659 bytes available) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; CTL-O if TRANLOGON has been set YES. You can put in several lines if
- ; desired. End with a 0.
- ;
- LOGON: DB 'this is the place for your message',CR,LF,0
- ;.....
- ;
- ;
- ; This routine allows a 300 ms. break tone to be send to reset some
- ; time-share computers.
- ;
- SENDBRK: MVI A,1DH ;SEND A BREAK TONE FOR 300 MS.
- JMP GOODBYE1
- ;.....
- ;
- ;
- ; This routine sends a 300 ms. break tone and sets DTR low for the same
- ; length of time to disconnect some modems such as the Bell 212A, etc.
- ;
- GOODBYE: MVI A,05H ;SET BREAK, DTR LOW
- ;
- GOODBYE1: OUT MODCMD+4 ;PUT COMMAND REGISTER OUT OF MODE
- IN MODCMD ;MAKE SURE IT IS NOW CLEAR
- IN MODCMD ;TRY ONCE MORE
- MVI B,3 ;DELAY FOR 300 MS.
- CALL JMP$TIMER
- MVI A,37H ;RESET RTS, FLAGS, DTR LOW, ENABLE R/T
- OUT MODCMD+4 ;SEND TO COMMAND REGISTER
- IN MODCMD ;CLEAR ANY INCOMING CHARS.
- IN MODCMD ;TRY ONCE MORE
- XRA A ;CLEAR THE 'A' REG.
- RET
- ;.....
- ;
- ;
- ; The following are used in setting up the 2651B I/O port.
- ;
- INITMOD: MVI A,1 ;DEFAULT TRANSFER TIME TO 300 BAUD
- STA MSPEED
- XRA A ;SET RTS, FLAGS, DTR, DISABLE R/T
- OUT MODCMD+4 ;PUT COMMAND REGISTER OUT OF MODE
- IN MODCMD ;MAKE SURE IT IS NOW CLEAR
- IN MODCMD ;TRY ONCE MORE
- MVI A,4EH ;1 STOP, NO PARITY, 8 BITS, 16X ASYNCH
- OUT MODMODE+4 ;SEND TO MODE REGISTER 1
- ;
- INITMOD1: MVI A,0F5H ;START WITH 300 BAUD, INTERNAL 5.0 CLOCK
- OUT MODMODE+4 ;SEND TO MODE REGISTER 2
- MVI A,37H ;RESET RTS, FLAGS, DTR LOW, ENABLE R/T
- OUT MODCMD+4 ;SEND TO COMMAND REGISTER
- IN MODCMD ;CLEAR ANY INCOMING CHARS.
- IN MODCMD ;TRY ONCE MORE
- XRA A ;CLEAR THE 'A' REG.
- RET
- ;.....
- ;
- ;
- ; The following changes the baud rate with the SET command.
- ;
- SETUPR: LXI D,BAUDBUF
- CALL JMP$ILPRT
- DB 'Input Baud Rate (110, 300, 1200, 9600): ',0
- CALL JMP$INBUF
- LXI D,BAUDBUF+2
- CALL JMP$INLNCOMP
- DB '110',0
- JNC OK110
- CALL JMP$INLNCOMP ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW
- DB '300',0
- JNC OK300 ;GO IF GOT MATCH
- CALL JMP$INLNCOMP
- DB '1200',0
- JNC OK1200
- CALL JMP$INLNCOMP
- DB '9600',0
- JNC OK9600
- CALL JMP$ILPRT ;ALL MATCHES FAILED, ASK AGAIN
- DB '++ Incorrect entry ++',CR,LF,BELL,0
- JMP SETUPR ;TRY AGAIN
- ;
- OK110: MVI A,0 ;MSPEED 110 BAUD VALUE
- LHLD BD110 ;GET 110 BAUD PARAMETERS IN 'HL'
- JMP LOADBD ;GO LOAD THEM
- ;
- OK300: MVI A,1
- LHLD BD300
- JMP LOADBD
- ;
- OK1200: MVI A,5
- LHLD BD1200
- JMP LOADBD
- ;
- OK9600: MVI A,8
- LHLD BD9600
- ;
- LOADBD: STA INITMOD+1
- MOV A,L ;get least significant baud rate byte
- STA INITMOD1+1 ;store in INITMOD1
- JMP INITMOD ;reset Z-100 2661
- ;.....
- ;
- ;
- ; TABLE OF BAUDRATE PARAMETERS FOR 2661 I/O
- ;
- BD110: DW 00F4H
- BD300: DW 00F5H
- BD1200: DW 00F7H
- BD9600: DW 00FCH
- ;
- BAUDBUF: DB 10,0
- DS 10
- ;
- ;-----------------------------------------------------------------------
- ;
- ; The following routine could be used to display selections of interest
- ; to owners of this computer. If using the Hayes Smartmodem this is
- ; unavailable without a special change.
- ;
- SPCLMENU: RET
- ;
- ;-----------------------------------------------------------------------
- ;
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
- ; 0C00H (without Smartmodem)
- ;
- END
- ;