home *** CD-ROM | disk | FTP | other *** search
-
- ; M7MM-1.ASM -- Morrow Multi-I/O overlay for MDM7xx 11/11/83
- ;
- ; This overlay adapts the MDM7xx program to use a Morrow Mult-I/O board
- ; and an external modem. The Mult-I/O board supports several users at
- ; the same port address in a fashion similar to bank selecting main
- ; memory. This program includes an initialization routine to select
- ; the baud rate but does not change the user (group) number which is
- ; set to group 1.
- ;
- ; You could look at other overlay files to see how the GOODBYE and/or
- ; SETUPR areas are handled. You could then adapt one of those, if ap-
- ; propriate for your equipment in this overlay. Some examples:
- ;
- ; "DP" Datapoint 1560 overlay using 8251 I/O and CTC timers for
- ; setting baud rates
- ; "H8" Heath H89 overlay for 8250 I/O and programmable baud rates
- ; "HZ" Zenith 120 overlay for 2661B initialization and baud rates
- ; "XE" Xerox 820II overlay for Z80-SIO intialization, etc.
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ; A>DDT MDM7xx.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4300 0100
- ; -IM7MM-1.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4300 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 66 MDM7xx.COM (now have a modified .COM file)
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 11/11/83 - Renamed to M7MM-1.ASM, no changes - Irv Hoff
- ; 07/27/83 - Renamed to work with MDM712 - Irv Hoff
- ; 07/07/83 - Adapted for Morrow Multi-I/O - G. Smith
- ; 07/01/83 - Revised to work with MDM711 - Irv Hoff
- ; 07/01/83 - Revised to work with MDM710 - Irv Hoff
- ; 05/27/83 - Updated to work with MDM709 - Irv Hoff
- ; 05/15/83 - Revised to work with MDM708 - Irv Hoff
- ; 04/11/83 - Updated to work with MDM707 - Irv Hoff
- ; 04/04/83 - First version of this file - Irv Hoff
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- TAB: EQU 09H ;tab
- BDOS: EQU 0005H
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- ; Change the following information to match your equipment
- ;
- BASE: EQU 0F0H ;Base address for Mult-I/O board
- GROUP: EQU 1 ;Group selection code
- GRP$CTL: EQU BASE+7 ;Group selection port address
- DLL: EQU BASE ;ACE baud rate divisor (LSB)
- DLM: EQU BASE+1 ;ACE baud rate divisor (MSB)
- IER: EQU BASE+1 ;ACE interrupt enable register
- LCR: EQU BASE+3 ;ACE line control register
- LSR: EQU BASE+5 ;ACE line status register
- RBR: EQU BASE ;ACE receive buffer register
- THR: EQU BASE ;ACE transmit hold register
- DLAB: EQU 80H ;Divisor latch access bit
- THRE: EQU 20H ;MODSNDB
- DR: EQU 1 ;MODRCVB
- WLS0: EQU 1 ;Word length select bit 0
- WLS1: EQU 2 ;word length select bit 1
- STB: EQU 4 ;stop bit count (2 stops)
- IMASK: EQU 0 ;Interrupt mask -- disable all
- ;
- MODDCDB: EQU 4 ;CARRIER DETECT BIT
- MODDCDA: EQU 0 ;VALUE WHEN ACTIVE
- MODRCVB: EQU 1 ;BIT TO TEST FOR RECEIVE
- MODRCVR: EQU 1 ;VALUE WHEN READY
- MODSNDB: EQU 20H ;BIT TO TEST FOR SEND
- MODSNDR: EQU 20H ;VALUE WHEN READY
- ;
- ;
- ORG 100H
- ;
- ;
- ; Change the clock speed to suit your system
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-PMMI 104H
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB NO ;yes=user-added Setup routine 10BH
- SCRNTEST: DB NO ;Cursor control routine 10CH
- ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
- ;no=resend a record after a valid-NAK
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVBKSP: DB NO ;yes=convert backspace to rub 111H
- TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB YES ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB NO ;no=do not save CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
- NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
- LOGCHR: DB 'L'-40H ;^O = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
- UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
- EXTCHR: DB '^'-00H ; ^ = Send next character 127H
- ;
- ;
- DS 2 ; 128H
- ;
- ;
- IN$MODCTL1: CALL MOD$SEL ;in modem control port 12AH
- IN LSR
- RET
- ;.....
- ;
- ;
- DS 4
- ;
- OUT$MODDATP: PUSH PSW ;out modem data port 134H
- CALL MOD$SEL
- POP PSW
- OUT THR
- RET
- ;.....
- ;
- ;
- DS 2
- ;
- IN$MODDATP: CALL MOD$SEL ;in modem data port 13EH
- IN RBR
- RET
- ;.....
- ;
- ;
- DS 4
- ;
- ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
-
- CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
- ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
- CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
- DS 6 ; 156H
- ;
- OUT$MODCTL1: RET ! NOP ! NOP ;out modem control port #2 15AH
- OUT$MODCTL2: RET ! NOP ! NOP ;out modem control port #1 15DH
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER DS 3 ; 192H
- ;
- ;
- ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set
- ; SCRNTEST to YES at 010AH (above).
- ;
- CLREOS: CALL JMP$ILPRT ; 195H
- DB 16,0,0,0,0 ;Vector MT code for CLREOS 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ; 19EH
- DB 4,0,0,0,0 ;Vector MT code for CLRSCRN 1A1H
- RET ; 1A6H
-
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 'Computer with Morrow MIO board -- User #1'
- DB CR,LF,0
- RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0C00H (2659 bytes) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if
- ; desired. End with a 0.
- ;
- LOGON: DB 'How are you today?',CR,LF,0
- ;.....
- ;
- ;
- ; Add your own routine here to send a break tone to reset some time-share
- ; computers, if desired.
- ;
- SENDBRK: RET
- ;.....
- ;
- ;
- ; Add your own routine here to put DTR low and/or send a break tone.
- ; Check other routines such as MDM709DP.ASM which is using this feature.
- ;
- GOODBYE: RET
- ;.....
- ;
- ;
- ; You can use this area for any special initialization or setup you may
- ; wish to include. Each must stop with a RET. You can check the other
- ; available overlays for ideas how to write your own routines if that
- ; may be of some help.
- ;
- INITMOD: LXI D,BAUD$MSG ;Point to baud selection message
- MVI C,9 ;BDOS print string cmd
- CALL BDOS ;Use BDOS to print baud message
- LXI D,BAUD$BUF ;point to 1 char input buffer
- MVI C,10 ;BDOS cmd to fill buffer from CON:
- CALL BDOS
- LDA CHOICE ;Get the character from the buffer
- SUI 31H ;Subtract ASCII bias
- JC INITMOD ;Input must be > zero
- CPI 4 ;And less than 4
- JNC INITMOD ;Now we have 0,1,2,or3 in 'A' Register.
- RLC ;Mult by 2 for table offset
- STA CHOICE ;save for later
- MVI A,GROUP ;select group (user) number
- OUT GRP$CTL
- MVI A,DLAB ;Set data latch access bit
- OUT LCR
- LDA CHOICE ;get back offset into baud table
- LXI H,INITBLE ;point to table base
- ADD L ;add offset
- MOV L,A
- MOV A,M ;get low order byte for baud rate
- OUT DLL
- INX H ;point to next table entry
- MOV A,M ;and send it to baud register
- OUT DLM
- MVI A,WLS0+WLS1+STB ;8 bit data word & 2 stop bits
- OUT LCR
- IN RBR ;clear flags
- MVI A,IMASK ;set interrupt status (all disabled)
- OUT IER
- RET
- ;.....
- ;
- ;
- SETUPR: RET
- ;.....
- ;
- ;
- MOD$SEL: MVI A,GROUP ;Group select code
- OUT GRP$CTL ;Group select register
- MVI A,WLS0+WLS1+STB ;make sure DLAB is clear
- OUT LCR
- RET
- ;.....
- ;
- ;
- ; If using the Hayes Smartmodem this is unavailable without a special
- ; change.
- ;
- SPCLMENU: RET
- ;
- ;
- BAUD$MSG: DB CR,LF,TAB,'SELECT BAUD RATE (MIO user 1)'
- DB CR,LF,TAB,TAB,'1. 300'
- DB CR,LF,TAB,TAB,'2. 1200'
- DB CR,LF,TAB,TAB,'3. 4800'
- DB CR,LF,TAB,TAB,'4. 9600','$'
- ;
- BAUD$BUF: DB 01,00
- CHOICE: DB 00
- ;.....
- ;
- ;
- ; The initialization table is nothing more than a list of bytes to
- ; be send to the baud rate registers, in the same order as the choices
- ; in the baud message above. Note the MSB,LSB order within each entry.
- ;
- INITBLE: DB 80H,01 ;300 baud divisor = 0180H
- DB 60H,0 ;1200 baud divisor = 0C0H
- DB 18H,0 ;4800 baud divisor = 018H
- DB 0CH,0 ;9600 baud divisor = 00CH
- ;.....
- ;
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
- ; 0C00H (without Smartmodem)
- ;.....
- ;
- END
- ;