- ; M7MFIO-2.ASM For Electralogics Inc. MFIO. 04/30/84
- ;
- ; You will want to look this file over carefully. There are a number of
- ; options that you can use to configure the program to suit your taste.
- ; This file places particular emphasis on using the Electralogics MFIO
- ; board with 8250 serial I/O. Much of the information contained here is
- ; not in the main file.
- ;
- ; Set serial port desired at 'sio' equate
- ;
- ; Use the "SET" command to change baudrate when desired.
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ; A>DDT MDM7xx.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4x00 0100
- ; -IM7MFIO-2.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4x00 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
- ; ^
- ; May vary depending upon version of MDM7xx
- ;
- ;----------------------------------------------------------------------------
- ; NOTE:
- ;
- ; The MFIO is a very complex I/O board containing 8 serial ports, 2 parallel
- ; ports, a real time clock, and vectored interrupt controller. All of the
- ; above facilities can be accessed by the use of only 9 I/O port addresses.
- ; This requires that the active I/O block number be stored somewhere in memory
- ; so that when the current I/O operation is completed, the MFIO can be
- ; restored to its previous I/O block (normally the system console). I have
- ; selected location 0000FH for the purpose and called it 'BLKSTAT'.
- ; Any other unused memory location is equally suitable.
- ;
- ; If this procedure is adopted in all BIOS I/O routines, all that needs
- ; to be done in any other I/O routine is to select the current I/O block,
- ; set up the MFIO command port for that block and store that value at
- ; location 'BLKSTAT'. Following is my CONIN routine as an example:
- ;
- ; CONIN: mvi a,sio0 ; set sio0 for console I/O
- ; out cmdport ; and tell MFIO
- ; in linstat ; read the line status register
- ; ani ckrb ; & mask console kb rdy bit
- ; jz conin ; loop till ready
- ; in keydat ; read sio0 data register
- ; ani 7fh ; strip the parity bit
- ; push psw ; save the byte
- ; lda blkstat ; & get the previous I/O block
- ; out cmdport ; restore MFIO to prev block
- ; pop psw ; get the keyboard data byte
- ; ret ; and bail out
- ;
- ; The routine "mxdin" located near the end of this program is called from
- ; all routines which use BIOS I/O calls that utilize MFIO resources (in my
- ; system, ALL I/O except the disks is MFIO-oriented). Its only purpose is
- ; to ensure that the system keep track of the MFIO resource blocks. If you
- ; get really complicated (interrupts, for example) you may need to push
- ; and pop them using a 'stack'.
- ; 'nuff said. Luck!!
- ;
- ; - Bill Harnell
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 04/30/84 - Renamed and Revised for MDM7xx - Dennis Recla
- ;
- ; 08/14/83 - Revised to work with MFIO. - Vic Kass
- ; CONIN and CONOUT routines
- ; in your BIOS must reset
- ; modem port after any access!
- ;
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- ; Change the value at MODDATP if it does not match what you are using.
- ;
- sio: equ 02H
- blkstat: equ 0000fh ;location to store current I/O block
- cmdport: equ 48H
- ;
- MODDATP: EQU 40H ;data port for MFIO
- MODCTL1: EQU MODDATP+5 ;status port for MFIO
- MODRCVB: EQU 1 ;bit to test for received data
- MODRCVR: EQU 1 ;modem receive ready
- MODSNDB: EQU 20H ;bit to test for ready to send
- MODSNDR: EQU 20H ;modem send ready bit
- ;
- ;
- ORG 100H
- ;
- ; Change the clock speed if needed, to match your system
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- SMARTMODEM: DB NO ;yes=Smartmodem
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB YES ;yes=user-added Setup routine 10BH
- SCRNTEST: DB YES ;Cursor control routine 10CH
- ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
- ;no=resend a record after a valid NAK
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVBKSP: DB NO ;yes=convert backspace to rub 111H
- TOGGLEBK: DB NO ;yes=allow toggling of bksp to rub 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB YES ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB YES ;yes=do not overwrite CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
- NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
- LOGCHR: DB 'O'-40H ;^O = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
- UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
- EXTCHR: DB '^'-40H ;^^ = Send next character 127H
- ;
- ;
- DS 2 ; 128H
- ;
- IN$MODCTL1: call mxdin ;set & store current I/O block
- IN MODCTL1 ! RET ;in modem control port 12AH
- DS 4
- OUT$MODDATP: call mxdin
- OUT MODDATP ! RET ;out modem data port 134H
- DS 4
- IN$MODDATP: call mxdin
- IN MODDATP ! RET ;in modem data port 13EH
- DS 4
- ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
- CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
- ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
- CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
- DS 12 ;PMMI only calls 154H
- ;
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER DS 3 ; 192H
- ;
- ;
- ; Set the following clear screen codes for your terminal type
- ;
- CLREOS: CALL JMP$ILPRT ; 195H
- DB ESC,'Y',0,0,0 ; 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ; 19EH
- DB ESC,'+',0,0,0 ; 1A1H
- RET ; 1A6H
- ;
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 'Version for Electralogics Incorporated MFIO'
- DB CR,LF,0
- RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0C00H (2659 bytes) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; CTL-O if TRANLOGON has been set TRUE. You can put in several lines if
- ; desired. End with a 0.
- ;
- LOGON: DB 'Hello...... >> Bill Harnell<< here....',CR,LF,0
- ;.....
- ;
- ;
- ; This routine sends a 300 ms. break tone to reset some time-share
- ; computers.
- ;
- SENDBRK: call mxdin ;set & store current I/O block
- MVI A,40H ;SET BREAK TONE
- OUT MODDATP+3
- JMP GOODBYE1 ;SEND A 300 MS. BREAK TONE
- ;.....
- ;
- ;
- ; This routine sends a 300 ms. break tgone and set DTR low for the same
- ; length of time to disconnect some modems such as the Bell 212A, etc.
- ;
- GOODBYE: call mxdin
- XRA A
- OUT MODDATP+4 ;SET DTR AND RTS LOW
- MVI A,40H ;SET BREAK TONE
- OUT MODDATP+3
- ;
- GOODBYE1: MVI B,3 ;WAIT 300 MS.
- CALL JMP$TIMER
- MVI A,03H ;RESET TO NORMAL 8 BITS
- OUT MODDATP+3
- MVI A,01H
- OUT MODDATP+4 ;RESET DTR HIGH
- RET
- ;.....
- ;
- ;
- ; The following is used to initialize the MFIO 8250 I/O port 'SIO'
- ;
- INITMOD: MVI A,1 ;default transfer speed to 300 baud
- call mxdin
- STA MSPEED
- DI ;turn off interrupts for init.
- XRA A
- OUT MODDATP+1 ;interrupt enable register
- MVI A,80H ;insure out of mode to set baud rate
- OUT MODDATP+3 ;line control register
- OUT MODDATP+3
- ;
- LSPSPD: MVI A,80H ;default 'LSP' speed for 300 baud
- OUT MODDATP ;register for 'LSP' speed if enabled
- ;
- MSPSPD: MVI A,01H ;default 'MSP' speed for 300 baud
- OUT MODDATP+1 ;register for 'MSP' speed if enabled
- ;
- MVI A,03H ;8-level, 1 stop bit, no parity
- OUT MODDATP+3 ;line control register
- MVI A,01H ;set 'DTR' for proper modem output level
- OUT MODDATP+4 ;modem control register
- EI ;restore interrupts to normal
- RET
- ;.....
- ;
- ;
- ; The following routine changes the baud rate for the MFIO with the SET
- ; command.
- ;
- SETUPR: call mxdin
- LXI D,BAUDBUF ;point to input buffer for INLNCOMP
- CALL JMP$ILPRT
- DB 'Input Baud Rate (300, 1200, etc.): ',0
- CALL JMP$INBUF
- LXI D,BAUDBUF+2
- CALL JMP$INLNCOMP ;compare BAUDBUF+2 with characters below
- DB '300',0
- JNC OK300 ;go if got match
- CALL JMP$INLNCOMP
- DB '450',0
- JNC OK450
- CALL JMP$INLNCOMP
- DB '600',0
- JNC OK600
- CALL JMP$INLNCOMP
- DB '1200',0
- JNC OK1200
- CALL JMP$INLNCOMP
- DB '9600',0
- JNC OK9600
- CALL JMP$ILPRT ;all matches failed - tell operator
- DB '++ Incorrect entry ++',CR,LF,BELL,0
- JMP SETUPR ;try again
- ;
- OK300: MVI A,1 ;MSPEED 300 baud value
- LHLD BD300 ;get 300 baud parameters in HL
- JMP LOADBD ;go load them
- ;
- OK450: MVI A,2
- LHLD BD450
- JMP LOADBD
-
- OK600: MVI A,3
- LHLD BD600
- JMP LOADBD
- ;
- OK1200: MVI A,5
- LHLD BD1200
- JMP LOADBD
- ;
- OK9600: MVI A,8
- LHLD BD9600
- ;
- LOADBD: STA INITMOD+1 ;store speed to show transfer time
- MOV A,L ;get least significant baud rate byte
- STA LSPSPD+1 ;store in INITMOD
- MOV A,H ;get most signifcant baud rate byte
- STA MSPSPD+1 ;store in INITMOD
- JMP INITMOD ;reset MFIO 8250
- ;
- ;
- ; Table of baud rate parameters
- ;
- BD300: DW 0180H
- BD450: DW 0100H
- BD600: DW 00C0H
- BD1200: DW 0060H
- BD9600: DW 000CH
- ;
- BAUDBUF: DB 10,0
- DS 10
- ;
- ;-----------------------------------------------------------------------
- ;
- ; This routine can be used for your equipment, be sure to end with RET
- ; If using the Hayes Smartmodem this is unavailable without a special
- ; change.
- ;
- SPCLMENU: RET
- ;
- ;-----------------------------------------------------------------------
- ;
- mxdin: push psw
- mvi a,sio
- out cmdport
- sta blkstat ;store current I/O block
- pop psw
- ret
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
- ; 0C00H (without Smartmodem)
- ;
- END
- ;