- ΓòÉΓòÉΓòÉ 1. Version Notice ΓòÉΓòÉΓòÉ
-
- First Edition (October 1992)
-
- The following paragraph does not apply to the United Kingdom or any country
- where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS
- MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY
- KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
- WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states
- do not allow disclaimer of express or implied warranties in certain
- transactions; therefore, this statement may not apply to you.
-
- This publication could include technical inaccuracies or typographical errors.
- Changes are periodically made to the information herein; these changes will be
- incorporated in new editions of the publication. IBM may make improvements
- and/or changes in the product(s) and/or the program(s) described in this
- publication at any time.
-
- It is possible that this publication may contain reference to, or information
- about, IBM products (machines and programs), programming, or services that are
- not announced in your country. Such references or information must not be
- construed to mean that IBM intends to announce such IBM products, programming,
- or services in your country.
-
- Requests for copies of this publication and for technical information about IBM
- products should be made to your IBM Authorized Dealer or your IBM Marketing
- Representative.
-
-
- ΓòÉΓòÉΓòÉ 2. Notices ΓòÉΓòÉΓòÉ
-
- References in this publication to IBM products, programs, or services do not
- imply that IBM intends to make them available in all countries in which IBM
- operates. Any reference to an IBM product, program, or service is not intended
- to state or imply that only that IBM product, program, or service may be used.
- Any functionally equivalent product, program, or service that does not infringe
- any of the intellectual property rights of IBM may be used instead of the IBM
- product, program, or service. The evaluation and verification of operation in
- conjunction with other products, except those expressly designated by IBM, are
- the responsibility of the user.
-
- IBM may have patents or pending patent applications covering subject matter
- described in this document. The furnishing of this document does not give you
- any license to these patents. You can send license inquiries, in writing, to
- the IBM Director of Commercial Relations, IBM Corporation, Purchase, New York,
- 10577, U.S.A.
-
- The licensed program described in this document and all licensed material
- available for it are provided by IBM under terms of the IBM Customer Agreement.
-
- This document is not intended for production use and is furnished as is without
- any warranty of any kind, and all warranties are hereby disclaimed including
- the warranties of merchantability and fitness for a particular purpose.
-
- The following terms, denoted by an asterisk (*) in this publication, are
- trademarks of the IBM Corporation in the United States or other countries.
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Advanced Peer-to-Peer Networking Γöé Micro Channel Γöé
- Γöé Application System/400 Γöé NetView Γöé
- Γöé APPN Γöé Operating System/2 Γöé
- Γöé AS/400 Γöé OS/2 Γöé
- Γöé AT Γöé Personal Computer AT Γöé
- Γöé FFST/2 Γöé Personal System/2 Γöé
- Γöé First Failure Support Technology/2 Γöé Presentation Manager Γöé
- Γöé IBM Γöé PS/2 Γöé
- Γöé Macro Assembler/2 Γöé System/370 Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- The following terms, denoted by a double asterisk (**) in this publication, are
- trademarks of other companies:
-
- Hayes Hayes Microcomputer Products, Inc.
- MCI MCI Communications Corporation.
- MicroCom MicroCom Systems, Inc.
- Micro Focus Micro Focus Limited
- Micro Focus COBOL/2 Micro Focus Limited
- National Semiconductor National Semiconductor Corporation
- Racal-Vadic Racal Electronics Public Limited Co.
- ROLMphone ROLM Systems
- Smartmodem Hayes Microcomputer Products, Inc.
- Sprint US Sprint Communications Company
- Microsoft Microsoft Corporation
-
-
- ΓòÉΓòÉΓòÉ 3. About This Book ΓòÉΓòÉΓòÉ
-
- IBM* Communications Manager/2 Version 1.0 (referred to in this book as
- Communications Manager) is a communications services platform. This platform
- provides a wide range of services for IBM Operating System/2* (OS/2*)
- workstations that communicate with host computers and with other workstations.
- Communications Manager users can choose from among a variety of remote
- connectivity options.
-
- IBM Communications Manager/2 Version 1.0 ACDI Programming Reference (referred
- to in the remainder of this book as ACDI Programming Reference) defines the
- Communications Manager Asynchronous Communications Device Interface (ACDI)
- application programming interface (API). It serves as a reference for
- programmers who want to use the C and Macro Assembler languages to create their
- own application programs using Communications Manager for the IBM Personal
- Computer AT* and for the the IBM Personal System/2* computer. The following
- compilers are supported:
-
- o Microsoft** C 6.0 (referred to as C in the remainder of this book) or its
- functional equivalent
-
- o Micro Focus** COBOL/2** (referred to as COBOL in the remainder of this book)
- or its functional equivalent
-
- o IBM Macro Assembler/2* (referred to as MASM in the remainder of this book) or
- its functional equivalent
-
- It is assumed that you are using OS/2 Version 1.30.1 with corrective service
- diskette (CSD) 5050 or higher or OS/2 Version 2.0 as your base operating
- system. The term OS/2, as it is used in the Communications Manager
- documentation and on the display during the running of the programs, refers to
- some or all components of the base operating system. If you use a base
- operating system that is functionally equivalent to OS/2 Version 1.30.1 with
- CSD 5050 or higher or OS/2 Version 2.0, the Communications Manager
- documentation still applies.
-
-
- ΓòÉΓòÉΓòÉ 3.1. Who Should Use This Book ΓòÉΓòÉΓòÉ
-
- This reference book is for application programmers who are familiar with both
- the asynchronous communications environment and the information provided in IBM
- Communications Manager/2 Version 1.0 User's Guide.
-
- Users should also know how to:
-
- o Write application programs in the C or Macro Assembler language
-
- o Configure the Communications Manager program to support the application
- programs that support ACDI
-
-
- ΓòÉΓòÉΓòÉ 3.2. How to Use This Book ΓòÉΓòÉΓòÉ
-
- The following sections describe the organization of this book and the
- conventions used throughout the Communications Manager library.
-
-
- ΓòÉΓòÉΓòÉ 3.2.1. How This Book Is Organized ΓòÉΓòÉΓòÉ
-
- This book contains the following chapters and appendixes:
-
- Communications Manager, Asynchronous Communications, and ACDI, provides the
- application programmer with an overview of ACDI and its relationship to the
- Communications Manager environment.
-
- ACDI Functions, Structure, and Verb Overview, provides an overview of
- asynchronous communications concepts as used in ACDI with an overview of ACDI
- features.
-
- Writing, Building, and Debugging Your Application Using ACDI, outlines the main
- topics in writing applications for ACDI.
-
- ACDI Verb Descriptions, provides a complete description of each ACDI verb.
-
- Using the ACDI Redirection API, describes how to use the ACDI Redirection
- application programming interface (API) and provides a detailed description of
- the six ACDI Redirection API functions.
-
- ACDI Return Codes, provides a complete list of ACDI return codes.
-
- ACDI Redirection API Return Codes, provides a complete list of ACDI Redirection
- return codes.
-
- An index follows the appendixes. Consult Glossary for definitions of terms used
- in this library. Glossary is available online and is separately orderable.
-
-
- ΓòÉΓòÉΓòÉ 3.2.2. Conventions Used in This Library ΓòÉΓòÉΓòÉ
-
- The following conventions are used throughout the Communications Manager
- library. Some of the conventions listed may not be used in this particular
- book.
-
-
- ΓòÉΓòÉΓòÉ 3.2.2.1. Text Conventions ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé BOLD Γöé Bold type indicates the following: Γöé
- Γöé Γöé Γöé
- Γöé Γöé o The names of window controls, such as lists, check Γöé
- Γöé Γöé boxes, entry fields, and menu choices. They appear in Γöé
- Γöé Γöé the text as they appear in the window. Γöé
- Γöé Γöé Γöé
- Γöé Γöé o Verbs, functions, and parameters that you can use in a Γöé
- Γöé Γöé program or at a command prompt. These values are case Γöé
- Γöé Γöé sensitive and should be entered exactly as they appear Γöé
- Γöé Γöé in the text. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé Italics Γöé Italics indicate a variable that you supply a value for. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé UPPERCASE Γöé Uppercase indicates constants, file names, keywords, and Γöé
- Γöé Γöé options that you can use in a program or at a command Γöé
- Γöé Γöé prompt. You can enter these values in uppercase or lower- Γöé
- Γöé Γöé case. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé "Example type" Γöé Example type indicates information that the user is Γöé
- Γöé Γöé instructed to type at a command prompt or in a window. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 3.2.2.2. Numbers Conventions ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Hexadecimal Γöé Represented as X'xxxx' except in certain instances where Γöé
- Γöé Γöé they are represented with text ("The location hex xxxx is Γöé
- Γöé Γöé the address of..."). In an example of assembly language Γöé
- Γöé Γöé code, a hexadecimal number is represented by a lowercase h Γöé
- Γöé Γöé following the hexadecimal characters. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé Binary Γöé Represented as B'xxxx xxxx' or B'x' except in certain Γöé
- Γöé Γöé instances where they are represented with text ("A value of Γöé
- Γöé Γöé binary xxxx xxxx is..."). Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé Bit positions Γöé Start with 0 at the rightmost position (least significant Γöé
- Γöé Γöé bit). Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 3.2.2.3. Syntax Diagrams ΓòÉΓòÉΓòÉ
-
- Throughout this library, conceptual diagrams are used to illustrate the
- programming syntax. The following list tells you how to interpret the syntax
- diagrams:
-
- o Read the syntax diagrams from left to right, from top to bottom, following
- the path of the line.
-
- o Items shown on the main path of the syntax statement are required syntax.
-
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
-
- o Items shown on branches below the main path are optional syntax.
-
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
- ΓööΓöÇITEM1ΓöÇΓöÿ ΓööΓöÇITEM2ΓöÇΓöÿ
-
- o Items shown on branches above the main path are default syntax.
-
- -ITEM1ΓöÇ.
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇ'ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ'ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
-
- o Items appearing in a stack indicate that only one of the items may be
- specified. When one of the items in a stack appears on the main path, you
- must choose one of the items.
-
- For example, in the following syntax diagram, you must choose either ITEM1 or
- ITEM2. ITEM3 and ITEM4 both appear below the main path, so neither of them
- is required.
-
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇΓö¼ΓöÇITEM1ΓöÇΓö¼ΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
- ΓööΓöÇITEM2ΓöÇΓöÿ Γö£ΓöÇITEM3ΓöÇΓöñ
- ΓööΓöÇITEM4ΓöÇΓöÿ
-
- o A repeat arrow shown above an item or a stack of items indicates that you can
- specify the item multiple times or specify more than one of the items. A
- character (such as a comma) on the repeat arrow line indicates that the items
- must be separated by that character.
-
- For example, in the following syntax diagram, you can specify both ITEM1 and
- ITEM2, but you must use a comma to separate the choices in your programming
- syntax.
-
- -,ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
- Γöé
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇΓöÇΓö¼ΓöÇITEM1ΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
- ΓööΓöÇITEM2ΓöÇΓöÿ
-
- o In some cases, when an item has additional items associated with it, an
- additional syntax diagram is shown that represents the full syntax of that
- item. For example, in the following syntax diagram, additional information
- that can be specified for ITEM1 appears in the "ITEM1" Variables syntax
- diagram.
-
- >>ΓöÇΓöÇKEYWORDΓöÇΓöÇkeyword_nameΓöÇΓöÇΓöñ ITEM1 Γö£ΓöÇΓöÇITEM2ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ><
- ITEM1 VARIABLES:
- Γö£ΓöÇΓöÇΓö¼ΓöÇvariable1ΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γö£ΓöÇvariable2ΓöÇΓöñ
- ΓööΓöÇvariable3ΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 3.3. What Is New in This Book ΓòÉΓòÉΓòÉ
-
- This book reflects the following changes made from Extended Services for OS/2.
-
- o ACDI Redirection application interface added
- o ACDI configuration information moved to Configuration Guide
- o Common services programming interface verbs moved to Application Programming
- Guide
-
-
- ΓòÉΓòÉΓòÉ 3.4. Where to Find More Information ΓòÉΓòÉΓòÉ
-
- The following sections list publications about Communications Manager, its
- installation, and its operation.
-
-
- ΓòÉΓòÉΓòÉ 3.4.1. Communications Manager/2 Version 1.0 Library ΓòÉΓòÉΓòÉ
-
- The following lists encompass all the books in the Communications Manager
- library. The words "IBM Communications Manager/2 Version 1.0" are actually
- part of the title of each book; however, in these lists, those words are
- omitted.
-
-
- ΓòÉΓòÉΓòÉ 3.4.1.1. Basic User Books ΓòÉΓòÉΓòÉ
-
- The following books provide the basic information you need to get your system
- installed and operational:
-
- o Overview
-
- This online publication provides a comprehensive view of Communications
- Manager. It includes a description of configuration, services, emulator
- functions, application programming interfaces, and a complete bibliography of
- Communications Manager documentation and related publications.
-
- o Quick Installation, SX75-0085
-
- This card provides you with a very brief set of instructions on how to start
- the installation of Communications Manager. It is intended primarily for
- those who want to accept most or all of the preselected choices during
- installation. Quick Installation provides only limited instructions to get
- you started. If you want more detailed information about installing
- Communications Manager, refer to Workstation Installation Guide.
-
- o Start Here, SC31-6104
-
- This book contains a brief overview of Communications Manager and guides you
- to the Communications Manager library and related publications. In addition,
- this book identifies tasks you need to perform related to planning,
- installing, and configuring Communications Manager, and it provides you with
- information sources to support these tasks.
-
- o Information and Planning Guide, SC31-7007
-
- This book provides an overview of Communications Manager, including
- descriptions of new and enhanced functions and productivity aids, information
- on administration and usage of Communications Manager, and system
- requirements. It also provides technical advice on performance and
- coexistence considerations, planning new installations, and migrating from
- previous releases.
-
- o Workstation Installation Guide, SC31-6169
-
- This book provides the steps and basic information to install Communications
- Manager. This book also contains information about using a response file and
- changing a configuration.
-
- o Configuration Guide, SC31-6171
-
- This book describes how to configure Communications Manager for various
- connections and features. It also describes advanced user tasks, such as how
- to use the keylock function to protect configuration files.
-
- o Configuration Worksheets, SX75-0088
-
- A set of worksheets for the user or network administrator to map
- configurations for Communications Manager.
-
- o User's Guide, SC31-6108
-
- This book provides information necessary to accomplish basic communications
- tasks using Communications Manager. For example, this volume contains
- information and procedures for starting and stopping Communications Manager,
- using the clipboard to mark and copy data from one application to another,
- using 3270 and 5250 emulation, transferring files, and printing files. In
- addition, this book explains how to use keyboard remap for changing the
- functions of the keys on your terminal emulation keyboard. It also explains
- how to use messages and the message log.
-
- o Keyboard Templates, SX75-0073
-
- This documentation provides templates to place on your workstation keyboard
- that show you the keystrokes to use for 3270 and 5250 functions.
-
- o Command Reference
-
- This online documentation lists the Communications Manager commands and their
- syntax diagrams. It also describes Communications Manager device drivers.
-
- o Glossary, SC31-6155
-
- This book defines technical terms and acronyms that are used throughout the
- Communications Manager program and publications. It is available online and
- is separately orderable in hard copy.
-
-
- ΓòÉΓòÉΓòÉ 3.4.1.2. Advanced User Books ΓòÉΓòÉΓòÉ
-
- The following separately orderable books provide advanced planning and
- installation information for Communications Manager:
-
- o Network Administration and Subsystem Management Guide, SC31-6168
-
- This book defines concepts and planning procedures for configuration,
- installation, and networking considerations. It also describes how to prepare
- a response file and how to use a response file to create or modify a
- configuration. Network Administrator Sample Program Diskette, which contains
- sample response files, is shipped with this book.
-
- o Scenarios, SC31-6174
-
- This book contains sample scenarios with steps to install and configure
- several different kinds of networks with attached workstations.
-
- o Problem Determination Guide, SC31-6156
-
- This book describes Communications Manager diagnostic tools and provides
- instructions for using them, including specific directions for using First
- Failure Support Technology/2* (FFST/2*) to identify problems or errors. It
- also contains reference information to assist in problem determination, as
- well as a Problem Report Form to use when contacting IBM.
-
- o Host Connection Reference, SC31-6170
-
- This book contains parameter matching and sample system generations for OS/2
- connections to System/370* (S/370) and Application System/400* (AS/400*)
- hosts.
-
- o Service Point Application Router and Remote Operations Service Guide,
- SC31-7006
-
- This book contains guidance and reference information for using two
- Communications Manager functions, Service Point Application Router and Remote
- Operations Service, to handle network management commands directed to a
- workstation by a NetView* operator or an application program.
-
- o Message Reference, SC31-6159
-
- This book contains the text, explanations, and suggested actions for all
- Communications Manager messages, including alerts and errors. This document
- is also available online.
-
-
- ΓòÉΓòÉΓòÉ 3.4.1.3. Programming Books ΓòÉΓòÉΓòÉ
-
- The following books provide Communications Manager application programming
- interface (API) information for creating and maintaining Communications Manager
- programs:
-
- o Application Programming Guide, SC31-7012
-
- This book describes application program development for Communications
- Manager. It is the starting point for writing application programs that use
- any of the Communications Manager application programming interfaces (APIs)
- and contains information common to all of the APIs. The Communications
- Manager/2 API Support Diskette, which contains sample programs, API data
- structures, and header files, is provided with this book.
-
- o ACDI Programming Reference, SC31-6161
-
- This book introduces and defines the procedures for using the Asynchronous
- Communications Device Interface (ACDI). This book serves as a reference for
- programmers who want to use the asynchronous programming functions to create
- their own application programs using C and Macro Assembler languages.
-
- o APPC Programming Guide and Reference, SC31-6160
-
- This book provides information necessary to create application programs in
- the C, COBOL, or Macro Assembler programming languages that use the advanced
- program-to-program communications (APPC) programming interface functions.
-
- o Conventional LU Application Programming Reference, SC31-6166
-
- This book provides information necessary to create application programs in
- the C, COBOL, or Macro Assembler programming languages that use the IBM OS/2
- Conventional LU Application (LUA) programming interface.
-
- o ECF Server-Requester Programming Interface (SRPI) Reference, SC31-6165
-
- This book provides programmers with the information necessary to create
- requester application programs that use the Server-Requester Programming
- Interface (SRPI) functions in Communications Manager.
-
- o EHLLAPI Programming Reference, SC31-6163
-
- This book defines the Emulator High-Level Language Application Programming
- Interface (EHLLAPI). Applications written to this programming interface can
- access and control the 3270 and 5250 host presentation spaces.
-
- o ISDN Connection Manager Interface (CMI) Programming Reference, SC31-7010
-
- This book describes how to use the integrated services digital network (ISDN)
- connection manager interface (CMI) to make a connection for user applications
- through a switched network.
-
- o ISDN Port Connection Manager (PCM) Programming Reference, SC31-7011
-
- This book describes how to develop and implement a call control module (a
- port connection manager) for use in Communications Manager's switched network
- environment.
-
- o Realtime Interface Co-Processor Device Driver Programming Reference,
- SC31-6164
-
- This book provides information for writing programs that support the Realtime
- Interface Co-Processor adapters. The dynamic link libraries, the application
- loader, and the device driver interface are discussed.
-
- o System Management Programming Reference, SC31-6173
-
- This book provides detailed descriptions of the Advanced Peer-to-Peer
- Networking* (APPN*) configuration and subsystem management verbs. These
- verbs allow configuration and management of APPN nodes.
-
- o X.25 Programming Reference, SC31-6167
-
- This book provides the information necessary to create application programs
- in the C, COBOL, or Macro Assembler programming languages that use the X.25
- API.
-
-
- ΓòÉΓòÉΓòÉ 3.4.2. Related Publications ΓòÉΓòÉΓòÉ
-
- The following publications are referred to in this book:
-
- o IBM Operating System/2 Technical Library, 10G3356
-
- The seventeen volumes in this library provide reference and tutorial
- information for OS/2 2.0 programming end user interfaces, device driver
- development, and application program development. The guidance information
- provides a complete guide to designing, writing, and building your
- application. The reference information is for all the application program
- interface (API) functions. The entire library can be ordered with a single
- part number.
-
- o IBM Systems Network Architecture Network Product Formats, LY43-0081-01
-
- This publication is a summary (at an architecture level) of the formats used
- between subarea nodes and SNA peripheral nodes, and between type 2.1 nodes
- using peer-to-peer protocols.
-
-
- ΓòÉΓòÉΓòÉ 4. Communications Manager, Asynchronous Communications, and ACDI ΓòÉΓòÉΓòÉ
-
- Communications Manager provides the user with comprehensive communications
- ability in a single system.
-
- ACDI functions do the following:
-
- o Provide device independence and support a variety of asynchronous
- communications devices and connection types such as:
-
- - Switched and non-switched lines
- - Modems (auto-dial, auto-answer, manual dial, manual answer)
- - Direct connections
-
- o Support asynchronous communications device command sets:
-
- - ATtention command set (an IBM-supplied and user-edited device command set
- that supports Hayes** Smartmodem** and compatibles)
-
- - CCITT V.25bis command set (an IBM-supplied and user-edited device command
- set that supports V.25bis)
-
- - No command set (a user-supplied device command set that supports circuits
- that adhere to CCITT V.24)
-
- o Support traditional asynchronous communication protocols such as:
-
- - Flow control
- - Break processing
-
- o Support two dissimilar external devices attached through an A/B switch
-
- o Provide ports for resource management:
-
- - Three asynchronous ports for computers with Micro Channel* buses (COM1,
- COM2, COM3)
-
- - Two asynchronous ports for computers with AT type buses (COM1, COM2)
-
- o Provide Communications and System Management (C & SM) support
-
- o Provide flexible input and output interfaces for data transfers
-
- o Manage application buffers for transmitted and received data
-
- o Provide asynchronous port sharing where auto-answer and auto-dial are
- allocated to the same port
-
- o Assist country requirements for connecting computers to telephone networks
-
- Communications Manager enables users to access a range of computers, including
- IBM and non-IBM host computer systems. In addition, several connections can be
- active concurrently, giving users rapid access to information from any point in
- a network. Communications Manager also provides a programming interface for
- asynchronous communications.
-
- The Asynchronous Communications Device Interface (ACDI) can be redirected to an
- IBM* Local Area Network Asynchronous Connection Server (LANACS) Version 2.0.
- LANACS is an IBM DOS product that provides asynchronous connection server
- capability to a LAN. The server that runs the LANACS program provides
- asynchronous resources-serial ports, asynchronous connection equipment, and
- telephone lines-that can be shared by workstations on a LAN. An Operating
- System/2* (OS/2*) workstation on the LAN can use serial ports on the
- asynchronous connection server as if the serial ports were located at the
- workstation. For more information on redirecting the serial ports, refer to
- User's Guide.
-
- ACDI is the programming interface that provides support for those who want to
- use the serial ports for asynchronous communications in a multitasking
- environment. ACDI interacts with the serial ports through the base operating
- system and ensures that interrupts are handled and data is buffered for
- applications as required.
-
- ACDI contains verbs that enable the programmer to set asynchronous
- communications parameters, such as character length, bit rate, and flow control
- mode, in addition to verbs for sending and receiving data through the serial
- port.
-
- ACDI is a high-level, hardware-independent interface. Application developers
- using ACDI need not worry about the hardware installed and applications need
- not change when a user changes hardware. This flexibility allows a programmer
- to develop and use an asynchronous communications protocol without having
- detailed knowledge of the asynchronous communications hardware or device
- drivers. For example, the application developer issues a ComConnect verb to
- ACDI to establish an asynchronous communications connection. ACDI directs the
- attached modem appropriately (based upon how the user has configured
- Communications Manager) to establish the connection.
-
- ACDI can be accessed from multiple applications concurrently. An individual
- application can perform asynchronous communications over a maximum of three
- serial ports on a Personal System/2* (PS/2*) workstation concurrently through
- ACDI.
-
-
- ΓòÉΓòÉΓòÉ 4.1. Communications and System Management Support ΓòÉΓòÉΓòÉ
-
- Communications Manager supports Communications and System Management (C & SM)
- by sending alerts to the host system over a Systems Network Architecture (SNA)
- connection when link-related failures are detected for Synchronous Data Link
- Control (SDLC) and asynchronous communications connections. If an IBM
- System/370* (S/370) host connection is not available, alerts and link
- statistics are logged locally.
-
- The alert and link statistics network management vector transport (NMVT) are
- also logged to the OS/2 system error log. The alert NMVT contains information
- about the type of errors detected, probable causes of failure, and recommended
- corrective actions when information is available. The information is made
- available at the central location for network problem determination and
- analysis. The link statistics NMVT contains statistics for an asynchronous
- communications session.
-
- For detailed information on alerts, refer to Problem Determination Guide.
-
-
- ΓòÉΓòÉΓòÉ 4.2. Using ACDI and ACDI Redirection Features ΓòÉΓòÉΓòÉ
-
- Before running your program, you must install the ACDI feature and the ACDI
- Redirection feature and start Communications Manager. For configuration
- information, refer to Configuration Guide. For information on starting and
- stopping ACDI, refer to User's Guide.
-
- The ACDI Redirection feature allows you to redirect ACDI using an application
- program. Using ACDI Redirection, you can set and query ACDI by interfaces other
- than a command line. For example, an ACDI application program can determine if
- a port is currently redirected.
-
-
- ΓòÉΓòÉΓòÉ 5. ACDI Functions, Structure, and Verb Overview ΓòÉΓòÉΓòÉ
-
-
- ACDI defines the interface for asynchronous communications in the
- Communications Manager program and provides a logical interface that is
- hardware-independent. It also provides a higher level function than traditional
- asynchronous communications device support.
-
- ACDI Architectural Layers provides a general view of how ACDI architectural
- layers are structured:
-
- ACDI Architectural Layers
-
- Applications call the ACDI dynamic link library (DLL), which issues calls to
- the ACDI device driver. ACDI programs the asynchronous adapter and the attached
- supported modem.
-
- The device drivers, shipped with Communications Manager, drive the asynchronous
- communications adapter.
-
- ACDI supports a wide variety of asynchronous adapters and provides support for
- data circuit-terminating equipment (DCE). Refer to Network Administration and
- Subsystem Management Guide for the supported adapters.
-
-
- ΓòÉΓòÉΓòÉ 5.1. Establishing Asynchronous Communications Connections ΓòÉΓòÉΓòÉ
-
- An application written for ACDI can establish asynchronous communications
- connections in several ways. Once the connection is made, little difference
- exists between connection types.
-
-
- ΓòÉΓòÉΓòÉ 5.1.1. Connection Types ΓòÉΓòÉΓòÉ
-
- The connection types are:
-
- o Auto-dial, auto-answer.
-
- The application can instruct ACDI to dial a number and establish a connection
- or instruct ACDI to set up for answering an incoming call.
-
- o Manual dial, manual answer.
-
- The application can set up a user-established voice connection, instruct ACDI
- to switch a modem from voice to data mode, and assert either the originate or
- answer frequencies.
-
- o No command set support-user-established.
-
- ACDI monitors circuits according to CCITT V.24 recommendations but does not
- issue commands to any attached data circuit-terminating equipment (DCE). The
- user establishes the data connection.
-
- The auto-dial, auto-answer, manual dial, and manual answer connection types are
- available for ports configured for the following modems:
-
- o Hayes Smartmodem 1200, 2400
- o Hayes V-Series Modem Enhancer 1200, 2400
- o IBM PC Series 1200, 2400
- o MicroCom** AX/2400C, AX/9624C
- o Racal-Vadic** VI2422PA, VI2422S
-
- Note: The device initialization string for the VI2422S model is the default
- value of ^C|. When using the VI2422PA model, the device initialization
- string must be modified to a value of ATV.25 by means of ACDI
- configuration.
-
-
- o IBM 7855 V.42
- o IBM Asynchronous/SDLC V.32 Modem/A
-
- Only the auto-dial and auto-answer connection types are available when the port
- is configured for ROLMphone** 244PC.
-
- The connection type that has no command set support works for ports configured
- for Other modem or devices. For more information on configuration, refer to
- Configuration Guide.
-
-
- ΓòÉΓòÉΓòÉ 5.1.2. Device String Profile ΓòÉΓòÉΓòÉ
-
- A device string profile is used to specify to ACDI what type of modem is
- attached to a specific COM port. The profile defines the modem commands and
- modem responses used by ACDI to manage the modem. The default modem commands
- shipped with ACDI support Hayes ATtention command set and V.25bis command set.
- If your modem uses other commands, you may need to change the defaults in the
- device string profile. For detailed descriptions on specific device strings
- used with asynchronous connections, see ComOpen (X'02').
-
-
- ΓòÉΓòÉΓòÉ 5.1.3. Asynchronous Port Sharing ΓòÉΓòÉΓòÉ
-
- ACDI allows two processes to share the same communication port if the port is
- not configured as Other modem or devices. For a further description, refer to
- Configuration Guide.
-
- Both processes can set:
-
- o Input and output buffers for the port
- o Rates and communications parameters for the port
- o Flow control parameters
- o Event notification parameters
- o Time-out values
- o Error substitution characters
-
- ACDI tracks the information for both processes. Each process can use the port
- serially for establishing a connection. When a process issues a successful
- ComConnect verb, it owns the communication port, and ACDI enables its
- communications parameters.
-
- If the second process issues a ComConnect verb while the first process has a
- connection established, it receives a return code indicating that the port is
- in use.
-
- When the first process ends its connection, both processes can attempt to
- establish a new connection. The first one to issue a ComConnect verb owns the
- port until the connection ends.
-
- All communications devices, except for those classified as V.24-compatible
- devices that do not have a command set or whose telephony command sets are not
- known by ACDI, can be shared. Ports configured as Other modem or devices cannot
- be shared.
-
- ACDI saves the current port parameters for each process and activates those
- parameters before a ComConnect verb completes for that process.
-
- The following values are saved by ACDI for each port:
-
- o Send and receive speeds (bits per second)
- o Number of stop bits
- o Parity selection
- o Number of data bits
- o Flow control characters
- o Flow control mode
- o Flow control threshold levels
- o Event mask and semaphore handle
- o Application input and output buffers, associated I/O pointers and counters
- o Time-out values
- o Error substitution character and mode
- o Input mode (fixed-length block, variable-length block, or character) and the
- associated parameters
-
- ACDI provides additional port-sharing capability for a port that is used by an
- application for auto-answer. If a process issues a ComConnect verb to ACDI for
- auto-answer with infinite time-out, ACDI lets another process that issues a
- ComConnect verb for auto-dial borrow the communication port.
-
- ACDI lets the auto-dial process make its outgoing call and when the auto-dial
- process connection ends, ACDI reinstates the first process for auto-answer. The
- auto-answer process never knows that another process borrowed the port to place
- an outgoing call. ACDI holds the auto-answer process's ComConnect thread while
- the auto-dial process borrows the port.
-
- To allow port sharing, the process requesting the auto-answer connection must
- specify infinite time-out (X'0000') in the ConnectTimeout1 parameter of the
- ComConnect verb.
-
-
- ΓòÉΓòÉΓòÉ 5.2. Bit Rate and Line Control Parameters ΓòÉΓòÉΓòÉ
-
- ACDI provides verbs for programming bit rate and line control parameters at the
- data terminal equipment (DTE) or the data circuit-terminating equipment (DCE)
- interface on the asynchronous communications hardware.
-
- These verbs program the universal asynchronous receiver/transmitter (UART) on
- the asynchronous communications hardware adapter or internal modem for the
- following parameters:
-
- o Bit rate
- o Parity
- o Number of data bits
- o Number of stop bits
-
- Changing the bit rate and line control parameters after a connection is
- established can cause the following situations to occur:
-
- o The data the application receives is unintelligible.
-
- o The data the application transmits is unintelligible to the remote receiver.
-
- o The application is not able to disconnect the communications session
- successfully without closing the communications port.
-
- After the bit rate is set with the ComSetBitRate verb and an application issues
- the verb to establish a connection, the local modem and the remote system can
- renegotiate the line speed and set it to a different value than that set by the
- application. The application can request the interface speed between the UART
- and modem by issuing the ComRetBitRate verb.
-
- Note: Some networks require a 7-bit configuration to establish connections but
- may require a change to 8-bit for a file transfer protocol like XMODEM.
-
- Some modems and UARTs do not support all of the bit rates and line control
- parameters selectable with ACDI. The application must instruct ACDI to program
- the UART for values that the modem and UART support. Unsupported values may
- cause communications problems.
-
-
- ΓòÉΓòÉΓòÉ 5.3. Resource Management and Input/Output Processing ΓòÉΓòÉΓòÉ
-
- The ACDI interface for sending and receiving application data centers around
- circular application buffers that the application defines with the
- ComDefOutputBuff and ComDefInputverbs. The application uses these verbs to
- describe the location and length of its buffers to ACDI, and to describe the
- input mode.
-
-
- ΓòÉΓòÉΓòÉ 5.3.1. Overview of Character and Block Input/Output Processing ΓòÉΓòÉΓòÉ
-
- After defining these buffers to ACDI and establishing a connection with the
- ComConnectverb, the application can receive and send data in the following
- ways:
-
- o When data is received, ACDI places it directly into the input buffer defined
- by the application. The application can retrieve the data that is queued in
- the buffer by ACDI by using the ComReadCharString or ComReadBlock verb. It
- can inform ACDI how much of the previously returned data it has removed from
- the buffer queue.
-
- o When the application wants to transmit data, it requests buffer space from
- ACDI with the ComWriteCharString verb. ACDI returns the location and amount
- of free space in the output buffer. The application places its data into the
- output buffer. Next, the application tells ACDI the amount of data it has
- queued in the output buffer and makes a request for more free space by
- issuing the ComWriteCharString verb.
-
- ACDI manages the application input and output buffers as circular buffers or
- ring buffers. For example, when data is received, ACDI queues it starting at
- the beginning of the application input buffer. When ACDI reaches the end of the
- application input buffer, it starts queuing data at the beginning of the
- application input buffer, provided that space at the beginning of the buffer
- has been freed by the application.
-
- When ACDI reaches the end of the application output buffer, it starts obtaining
- new data to transmit from the beginning of the application output buffer,
- provided that new data has been written to the buffer.
-
- ACDI also tracks pointers into the buffer for the application. When an
- application issues a ComWriteCharString verb, ACDI returns a pointer to the
- free space remaining in the buffer and returns the length of the free space, so
- that the application can continue to fill the output buffer with data to
- transmit. Similarly, when an application issues a ComReadCharString or
- ComReadBlock verb, ACDI returns a pointer to the data queued in the buffer and
- returns the length of the data.
-
- Application Output Buffer Structure shows the data structure of an application
- output buffer:
-
- Application Output Buffer Structure
-
- The x's represent new data copied into the buffer by the application for ACDI
- to transmit. The o's represent data that the application told ACDI to transmit
- on previous ComWriteCharString verb requests. ACDI returns a pointer to the
- free space. The current amount of free space returned to the application is the
- sum of the two blocks of free space minus 1 byte. (ACDI always reserves 1 byte
- of data at the logical end of the free space.)
-
- Note: The application must consider the buffer wrap when it receives the
- pointer and the amount of free space available from ACDI.
-
-
- ΓòÉΓòÉΓòÉ 5.3.2. Input Processing Modes ΓòÉΓòÉΓòÉ
-
- ACDI provides the following three modes for processing received data:
-
- o Character mode
-
- Input Buffer in Character Mode shows an input buffer in character mode:
-
- Input Buffer in Character Mode
-
- When the application issues the ComReadCharString verb, it receives input
- data from ACDI and instructs ACDI that it has freed space in the input buffer
- (the application has finished processing some of the data that was returned
- on previous ComReadCharString verb requests). When needed, this free space is
- used by ACDI to queue incoming data. When ACDI returns the ComReadCharString
- verb request to the application, it returns a pointer to all of the data in
- the buffer. This data includes any new data that the application does not
- know about and any old data that the application has not yet freed.
-
- In the diagram in Input Buffer in Character Mode, the o's represent old data
- that the application has not freed and that ACDI returned to the application
- on previous ComReadCharString verb requests. The x's represent new data that
- has been queued in the buffer since the last ComReadCharString verb request
- was issued.
-
- o Fixed-length block mode
-
- The diagram in Input Buffer in Fixed-Length Block Mode depicts the input
- buffer in fixed-length block mode:
-
- Input Buffer in Fixed-Length Block Mode
-
- The application specifies this mode and a block length that ACDI uses to
- group incoming data into blocks on the ComDefInput verb.
-
- The application issues the ComReadBlock verb to receive data in this mode. On
- the ComReadBlock verb, ACDI returns a pointer to the next block of data in
- the buffer and returns the block length. If a complete block is not received,
- ACDI still returns the block length. See ComReadBlock (X'19') for additional
- information.
-
- o Variable-length block mode
-
- The diagram in Input Buffer in Variable-Length Block Mode depicts the input
- buffer in variable-length block mode:
-
- Input Buffer in Variable-Length Block Mode
-
- The application specifies up to five end-of-block (EOB) strings that ACDI
- should look for to divide incoming data into blocks. For example, an
- application can specify a carriage return and a line-feed pair as the EOB
- delimiter.
-
- In this input mode, the application issues the ComReadBlock verb to get input
- data, and ACDI returns a pointer to the data and the block length. Because
- ACDI does not strip the actual EOB string from the data, the block length
- includes the EOB string data.
-
-
- ΓòÉΓòÉΓòÉ 5.4. Flow Control ΓòÉΓòÉΓòÉ
-
- ACDI provides verbs that allow you to manage the flow of data between your
- application and the remote receiver or sender.
-
- In asynchronous communications, when one station cannot process incoming data,
- it can signal the remote station to stop sending data by sending the remote
- station an XOFF character. When the local station is able to receive data, it
- sends an XON character to signal the remote station to start sending data.
-
- An application can manage data flow on its own with functions provided by ACDI,
- or it can program ACDI to manage flow control automatically.
-
-
- ΓòÉΓòÉΓòÉ 5.4.1. Application Flow Control ΓòÉΓòÉΓòÉ
-
- An application can use ComStartTrans and ComStopTrans verbs to instruct ACDI to
- start or stop transmitting data in the application output buffer when the
- application recognizes that the remote receiver has sent an XON or XOFF
- character. When an application realizes that it cannot process more incoming
- data, it can use the ComTransImm verb to send an XOFF character to the remote
- sender. When it is able to resume processing data, it can use the ComTransImm
- verb to send an XON character to the remote sender.
-
-
- ΓòÉΓòÉΓòÉ 5.4.2. Automatic Flow Control ΓòÉΓòÉΓòÉ
-
- With the ComSetFlowMode verb, an application enables automatic flow control.
- ACDI detects XON and XOFF characters sent by the remote sender and
- automatically starts or stops sending data in the application output buffer. In
- this mode, ACDI removes the XON and XOFF characters from the incoming data
- stream. The characters are not placed in the application input buffer.
-
- When free space in the application input buffer declines to a certain
- threshold, ACDI sends the remote sender an XOFF character. When enough free
- space becomes available in the application input buffer, ACDI sends the remote
- sender an XON character.
-
- The ComSetFlowChar verb allows an application to define the XON and XOFF
- characters that ACDI detects in the incoming data stream and sends to the
- remote sender.
-
- The ComSetFlowThresh verb allows the application to set the levels of free
- space in the input buffer for which ACDI should send either an XON or XOFF
- character to the remote sender.
-
-
- ΓòÉΓòÉΓòÉ 5.5. Event Processing ΓòÉΓòÉΓòÉ
-
- ACDI uses an application-defined semaphore to notify the application that an
- asynchronous communications event has occurred. This semaphore can be either a
- RAM semaphore or a system semaphore.
-
- The application sets up a mask of the events for which it wants notification.
- When an enabled event occurs and the application notifies you when the event
- occurred, ACDI copies the event information into the application's event data
- area and clears the application's semaphore to signal that the event has
- occurred. See ComReadEvent (X'13') for more information on ACDI event
- processing.
-
-
- ΓòÉΓòÉΓòÉ 5.6. Country or Network Requirements ΓòÉΓòÉΓòÉ
-
- ACDI also enforces each country's requirements for auto-dialing and
- auto-answering based on a telephone network ID that the user specifies during
- configuration. For example, many countries have requirements for how often a
- computer can call a number within a certain amount of time. Some countries also
- have requirements for how long a computer should wait before answering a call.
-
- These requirements are enforced when the application issues a ComConnect verb.
- Connection attempts violating a country's telecommunications requirements are
- returned with an error code.
-
- Refer to Configuration Guide for additional information.
-
-
- ΓòÉΓòÉΓòÉ 5.7. Ending Asynchronous Communications ΓòÉΓòÉΓòÉ
-
- Asynchronous communications links established using ACDI can be disconnected or
- ended in any of the following ways:
-
- o The application issues a ComDisconnect verb.
- o The remote end disconnects the session.
- o A user requests an abnormal stop to the ACDI feature by selecting Stop
- Communications Abnormally from the Communications group.
-
- When an asynchronous connection is ended, ACDI logs a communications and system
- management (C & SM) vector containing link statistics, such as the average data
- transmission and data reception rates, in the OS/2 system error log. If
- Communications Manager is stopped, your program must be ended before you can
- restart Communications Manager and ACDI.
-
- For additional information on the OS/2 system error log, refer to Problem
- Determination Guide.
-
-
- ΓòÉΓòÉΓòÉ 5.8. Verb Overview ΓòÉΓòÉΓòÉ
-
- The functions and verbs that are supplied by ACDI are listed as follows and are
- grouped into functional categories. It is suggested that applications use
- specific threads for specific verbs. An E (event/status), O (output), or I
- (input) is listed next to the verb, indicating which thread is better suited
- for those verbs. The absence of E, O, or I means any thread can be used.
-
-
- ΓòÉΓòÉΓòÉ 5.8.1. Resource Management ΓòÉΓòÉΓòÉ
-
- ComClose
- Closes the specified communications device.
-
- ComDefInput (I)
- Defines the application input buffer and input mode.
-
- ComDefOutputBuff (O)
- Defines the application output buffer.
-
- ComOpen
- Opens a communications device for an application.
-
-
- ΓòÉΓòÉΓòÉ 5.8.2. Line Characteristics ΓòÉΓòÉΓòÉ
-
- ComRetBitRate
- Returns the bit rate for which the asynchronous receiver/transmitter
- hardware is programmed.
-
- ComRetLineCtrl
- Returns the current line control values for which the asynchronous
- receiver/transmitter hardware is programmed.
-
- ComSetBitRate
- Sets the bit rate of the asynchronous receiver/transmitter hardware.
-
- ComSetLineCtrl
- Sets the line control values for the asynchronous
- receiver/transmitter hardware.
-
-
- ΓòÉΓòÉΓòÉ 5.8.3. Application Flow Control ΓòÉΓòÉΓòÉ
-
- ComStartTrans
- Instructs ACDI to start transmitting data in the application buffer.
-
- ComStopTrans
- Instructs ACDI to stop transmitting data in the application buffer.
-
- ComTransImm
- Sends a character immediately.
-
-
- ΓòÉΓòÉΓòÉ 5.8.4. Automatic Flow Control ΓòÉΓòÉΓòÉ
-
- ComRetFlowChar
- Returns flow control (XOFF and XON) characters.
-
- ComRetFlowMode
- Returns flow control (XOFF and XON) mode, specifying whether
- automatic flow control is enabled.
-
- ComRetFlowThresh
- Returns flow control threshold levels for the application input
- buffer.
-
- ComSetFlowChar
- Sets flow control (XOFF and XON) characters.
-
- ComSetFlowMode
- Sets flow control (XON and XOFF) mode.
-
- ComSetFlowThresh
- Sets the flow control threshold levels for the application input
- buffer.
-
-
- ΓòÉΓòÉΓòÉ 5.8.5. Break Processing ΓòÉΓòÉΓòÉ
-
- ComSendBreak (O)
- Sends a break signal for the user-specified duration.
-
-
- ΓòÉΓòÉΓòÉ 5.8.6. Event Processing ΓòÉΓòÉΓòÉ
-
- ComGetLineInfo
- Returns information about the RS232-C circuits.
-
- ComReadEvent (E)
- Enables the communications event queue.
-
-
- ΓòÉΓòÉΓòÉ 5.8.7. Character and Block I/O Processing ΓòÉΓòÉΓòÉ
-
- ComDrainOutput (O)
- Blocks thread until the application output buffer is empty.
-
- ComFlushInput
- Clears the application input buffer.
-
- ComFlushOutput
- Clears the application output buffer.
-
- ComReadBlock (I)
- Reads a block of data from the application input buffer and frees the
- block returned on the previous ComReadBlock.
-
- ComReadCharString (I)
- Reads a character string from the application input buffer.
-
- ComRetErrorCharSub (I)
- Returns the current error substitution character and mode.
-
- ComRetTimeout
- Returns time-out values for the ComReadCharString, ComReadBlock, and
- ComWriteCharString verbs.
-
- ComSetErrorCharSub (I)
- Sets the current error substitution character and mode.
-
- ComSetTimeout
- Sets time-out values for the ComReadCharString, ComReadBlock, and
- ComWriteCharString verbs.
-
- ComUnblockThreads
- Unblocks the specified thread if it is currently blocked.
-
- ComWriteCharString (O)
- Writes new data in the application output buffer and gets updated
- free space in the buffer.
-
-
- ΓòÉΓòÉΓòÉ 5.8.8. Connection Control ΓòÉΓòÉΓòÉ
-
- ComConnect
- Establishes an asynchronous communications connection.
-
- ComDisconnect
- Disconnects the asynchronous communications connection.
-
-
- ΓòÉΓòÉΓòÉ 5.9. Communications Manager Common Services API Service Verbs ΓòÉΓòÉΓòÉ
-
- Communications Manager also supplies service verbs that can be used by all
- application programs that use a Communications Manager API. The Common Services
- API (service verbs) provides the following functions:
-
- o Converts ASCII data to EBCDIC data
- o Converts EBCDIC data to ASCII data
- o Builds code-page conversion tables
- o Traces API interfaces and data
- o Queues the OS/2 system error log on a user-supplied queue
- o Logs messages in the OS/2 system error log
- o Transfers diagnostic information to a host computer
-
- The service verbs provided by Communications Manager serve all of the
- application programs that use a Communications Manager API. For complete
- information on these verbs, refer to Application Programming Guide.
-
- A description of each verb in the Common Services API follows:
-
- CONNECT_PHYSICAL_LINK
- Enables an X.25 physical link.
-
- CONVERT
- Converts ASCII character strings to EBCDIC and EBCDIC character
- strings to ASCII.
-
- COPY_TRACE_TO_FILE
- Formats the data in the trace storage buffer and copies it to a
- specified file.
-
- DEFINE_DUMP
- Selects the components for which dumping is to be performed and
- specifies the file to which the data is to be written.
-
- DEFINE_TRACE
- Specifies those API verbs and data on which an internal trace can be
- run, and turns a trace on or off, as specified.
-
- DISCONNECT_PHYSICAL_LINK
- Disables an X.25 physical link.
-
- DISPLAY
- Returns configuration information and current operating values for
- the active SNA node.
-
- DISPLAY_APPN
- Returns information about Advanced Peer-to-Peer Networking* (APPN*)
- resources.
-
- GET_CP_CONVERT_TABLE
- Provides a utility service for building a conversion table from one
- code page supported by Communications Manager to another code page.
-
- LOG_MESSAGE
- Instructs Communications Manager to record a previously created
- message in the message log.
-
- SET_USER_LOG_QUEUE
- Defines a user-supplied queue. The user creates the queue before this
- verb is issued and sends messages, error logs, or both to the queue.
-
- TRANSFER_MS_DATA
- Builds and sends an unsolicited network management vector transport
- (NMVT) request/response unit (RU) to the System Services Control
- Point (SSCP).
-
-
- ΓòÉΓòÉΓòÉ 6. Writing, Building, and Debugging Your Application Using ACDI ΓòÉΓòÉΓòÉ
-
- This chapter outlines the main topics for writing, building, and debugging your
- applications for ACDI.
-
-
- ΓòÉΓòÉΓòÉ 6.1. Writing Your Application ΓòÉΓòÉΓòÉ
-
- Applications written in either C or Macro Assembler language can use the
- following include files provided by Communications Manager for writing an
- application to ACDI:
-
- o ACDI_C.H for C
- o ACDI_A.INC for Macro Assembler
-
- These language bindings contain constant definitions for ACDI return codes,
- verb function codes, parameter values, and structure mappings for the verb
- control blocks.
-
-
- ΓòÉΓòÉΓòÉ 6.1.1. Using Versions of ACDI ΓòÉΓòÉΓòÉ
-
- The Version parameter identifies the ACDI version for which your application is
- written. The valid values for the Version parameter are X'00', X'01', X'02',
- X'03', and X'04'.
-
- If you have an application that was written for a previous ACDI version and you
- want to update the application to use any new verb functions in this version of
- ACDI, you need to change the Version parameter for the verb that has been
- enhanced and add any new parameters required by the new version of the verb.
- See the individual verb descriptions to determine the supported ACDI versions
- and parameters for each verb.
-
- If you are writing a new application, you can set the version in all of the
- verb control blocks that you use to call ACDI to the latest version. When you
- are designing a new application that you expect to run only on a specific
- version, you do not need to concern yourself with using other version values.
-
- As new functions are added to ACDI and as the ACDI interface is expanded, your
- application will be able to use ACDI in different ways.
-
-
- ΓòÉΓòÉΓòÉ 6.1.2. Calling ACDI ΓòÉΓòÉΓòÉ
-
- The high-level language syntax for calling ACDI is:
-
- call ACDI (addr(verb control block))
-
- where the address of the verb control block is a far address and the call to
- ACDI is a far call.
-
- For the C language, a sample call to ACDI is:
-
- extern void pascal far ACDI (unsigned far *);
- ACDI (vcbptr);
-
- For Macro Assembler, a sample call to ACDI is:
-
- EXTRN ACDI:FAR
-
- PUSH SEG VCB
- PUSH OFFSET VCB
- CALL FAR PTR ACDI
-
- An application must build the verb control block that it passes to ACDI in a
- read/write data segment. Threads of execution that call ACDI concurrently must
- call ACDI with separate control blocks, and an application should not change
- the content of a control block while ACDI is processing the verb associated
- with the control block.
-
- Note: If the pointer to the verb control block is not valid, X'02' is returned
- in the AX register. For more information, see ACDI Return Codes.
-
- ACDI and OS/2 require up to 2650 bytes of stack space for processing. Each
- application thread that calls an ACDI function needs to allocate an additional
- 2650 bytes of stack space.
-
-
- ΓòÉΓòÉΓòÉ 6.1.3. Thread Usage ΓòÉΓòÉΓòÉ
-
- Multiple applications can call the ACDI DLL and each application can call ACDI
- from multiple threads. An application can also establish communications
- connections over multiple communication ports through ACDI.
-
- An application using ACDI typically creates three threads of execution for
- controlling each port. They are:
-
- o Event/status processing
- o Reading (input)
- o Writing (output)
-
- The opening and closing of each communication port can take place in any thread
- of the process. Once a handle is obtained by an opened port, calls are made
- from the specific threads. Applications should use specific threads for
- specific verbs. In the Verb Overview, an E (event/status), O (output), or I
- (input) is listed next to the verb indicating which thread is better suited for
- that verb. The absence of E, O, or I means any thread can be used.
-
-
- ΓòÉΓòÉΓòÉ 6.1.4. Segment Attributes ΓòÉΓòÉΓòÉ
-
- The segment containing the control block must be a read/write data segment. If
- the verb has an associated data buffer, the segment containing the data buffer
- must also be a read/write data segment.
-
- Because the ACDI DLL routine runs under the caller's thread and performs all
- its own verb processing, control blocks and data segments may reside in shared
- memory created by DosAllocSeg or in the program's local data segment. When
- shared memory is used, multiple segments may be allocated for different data
- buffers. However, no data buffer may span multiple segments. Multiple control
- blocks and data buffers may coexist in the same segment, provided the preceding
- segment requirements are met.
-
-
- ΓòÉΓòÉΓòÉ 6.1.5. Application Exit List Processing ΓòÉΓòÉΓòÉ
-
- When an application successfully opens a communication port with the ComOpen
- verb, ACDI puts itself on the application's exit list. When an application
- closes all of the communication ports it opened through ACDI, ACDI removes
- itself from the application's exit list.
-
- If the application puts itself on its own OS/2 exit list, the application
- should not call ACDI from its exit list routine. There is no need for the
- application to perform ACDI cleanup on its exit list since ACDI does its own
- cleaning up for the application. Refer to OS/2 Technical Library for a
- description of the OS/2 exit list.
-
-
- ΓòÉΓòÉΓòÉ 6.2. Building Your Application ΓòÉΓòÉΓòÉ
-
- For information about compiling your application program, refer to your
- compiler documentation.
-
-
- ΓòÉΓòÉΓòÉ 6.2.1. Dynamic Link Interface ΓòÉΓòÉΓòÉ
-
- The base operating system provides two types of dynamic linking to the DLL:
-
- o Load-time linking
- o Run-time linking
-
- To link to ACDI at load time, you must either include an IMPORTS statement in
- the .DEF file that you use to link your program, or you must link with the
- ACS.LIB library at link time. ACS.LIB is in \CMLIB.
-
- The IMPORTS statement is:
-
- IMPORTS ACDI.ACDI
-
- The ACS.LIB library contains entry-point linkage information for all of the
- Communications Manager API entry points.
-
- Run-time linking provides the ability to link conditionally to a DLL. With
- run-time linking, your application issues the OS/2 DosLoadModule and
- DosGetProcAddr function calls to obtain linkage to the ACDI entry point. The
- name of the ACDI dynamic link library is ACDI.DLL, and the name of the entry is
- ACDI. ACDI.DLL is in \CMLIB\DLL.
-
- Although run-time linking is supported by ACDI, the capability to unlink is not
- supported. Once an application has performed the run-time link to ACDI.DLL, it
- should not unlink using the OS/2 DosFreeModule function call.
-
- Refer to Application Programming Guide and OS/2 Technical Library for
- additional information on run-time linking.
-
-
- ΓòÉΓòÉΓòÉ 6.2.2. Linking Your Program ΓòÉΓòÉΓòÉ
-
- Before you can run your program, you must create a program module to run on the
- base operating system (an .EXE file) by linking your compiled source files with
- the LINK utility supplied with your compiler.
-
- For additional information on the linking process, refer to OS/2 Technical
- Library. For specific guidelines about linking Communications Manager APIs, see
- Application Programming Guide.
-
-
- ΓòÉΓòÉΓòÉ 6.3. Debugging Your Application ΓòÉΓòÉΓòÉ
-
- Communications Manager provides an API trace service for all calls to and
- returns from each of its application programming interfaces. The ACDI trace
- service logs the verb control block that your application passes to ACDI as
- well as the verb control block that ACDI returns to your application on each
- call to ACDI.
-
- Refer to Problem Determination Guide for an example trace and additional
- information.
-
-
- ΓòÉΓòÉΓòÉ 7. ACDI Verb Descriptions ΓòÉΓòÉΓòÉ
-
- ACDI provides the verbs listed in this chapter to serve application programs
- that use ACDI. Return codes are provided with each verb.
-
-
- ΓòÉΓòÉΓòÉ 7.1. ComClose (X'03') ΓòÉΓòÉΓòÉ
-
- ComClose (X'03')
-
- This verb closes the specified communications device.
-
- Prerequisite Calls
-
- ComOpen
-
- Note: There can be no outstanding ComReadBlock, ComReadCharString,
- or ComWriteCharString verbs.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'03'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'11' Requests outstanding.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- When an application successfully issues ComClose, the application no
- longer owns the port. If the application no longer owns a
- communication port through ACDI, ACDI removes itself from the
- application's OS/2 exit list. Refer to OS/2 Technical Library for a
- description of the OS/2 exit list.
-
-
- ΓòÉΓòÉΓòÉ 7.2. ComConnect (X'21') ΓòÉΓòÉΓòÉ
-
- ComConnect (X'21')
-
- This verb establishes an asynchronous communications connection.
-
- Prerequisite Calls
-
- ComOpen
- ComDefInput
- ComDefOutputBuff
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CONNECTTYPE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CONNECTTIMEOUT1 Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CONNECTTIMEOUT2 Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENETPREFIXLNG Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENETPREFIXPTR Γöé X Γöé Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENETSUFFIXLNG Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENETSUFFIXPTR Γöé X Γöé Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENUMBERLNG Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELENUMBERPTR Γöé X Γöé Γöé Doubleword Address Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'21'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- ConnectType
- Defined as follows:
-
- Type Description
-
- 0 Used for manual connection to the destination and for
- the establishment of the data connection by the DCE with
- the originate frequency. The user establishes the voice
- connection. When ACDI receives a ComConnect verb for
- this type, ACDI commands the attached DCE to switch to a
- data connection with the originate frequency. The
- command string passed to the DCE is the voice to the
- data originate string.
-
- 1 Used for manual connection to the destination and for
- the establishment of data connection by the DCE with the
- answer frequency. The user establishes the voice
- connection, and when ACDI receives a ComConnect verb for
- this type, ACDI commands the attached DCE to switch to a
- data connection with the answer frequency. The command
- string passed to the DCE is the voice to the data answer
- string.
-
- 2 For automatic data dialing, the connect string passed to
- the DCE consists of configured strings and command
- strings passed on this verb.
-
- 3 For automatic data answering, the command string passed
- to the DCE is the voice to the data answer string if
- ACDI is managing an auto-answer delay. If not, the
- auto-answer string is used.
-
- 4 Used for activating other connections. For example,
- user-configured V.24/RS-232C devices with data switches,
- or direct connections to hosts. No command string passes
- to the DCE for this connect type.
-
- ConnectTimeout1, ConnectTimeout2
- Defined as follows:
-
- For ConnectType=0, 1, or 4 ConnectTimeout1 should be set to
- X'0000'. ConnectTimeout2 determines how long ACDI waits
- for the connection to be established before returning
- the ComConnect verb with a time-out return code.
- ConnectTimeout2 is in the range X'0001' to X'FFFF'.
-
- The time-out value is in the range of 1 to 65535
- seconds. The time is started when the command (and
- equivalent circuit behavior) is sent to the device.
-
- For ConnectType=2 ConnectTimeout1 should be set to X'0000'.
- ConnectTimeout2 determines how long ACDI waits for the
- connection to be established before returning the
- ComConnect verb with a time-out return code.
- ConnectTimeout2 is in the range X'0001' to X'FFFF'.
-
- The time-out value is in the range of 1 to 65535
- seconds. This is the amount of time to wait before
- disconnecting or hanging up. The time is started when
- the command (and equivalent circuit behavior) is sent to
- the device.
-
- If ConnectTimeout1 and ConnectTimeout2= X'0000', ACDI
- chooses a default that agrees with the requirements of
- the attached network.
-
- Note: Asking for a default is recommended.
-
- For ConnectType=3 ConnectTimeout1 indicates how long ACDI waits
- for a call to come in before returning with a time-out
- error. A value of 0 (X'0000') means infinite time-out.
- All other values (X'0001'to X'FFFF') specify a time-out
- in seconds. The time starts when the auto-answer command
- is sent to the device. When ConnectType=3,
- ConnectTimeout2 is ignored.
-
- TeleNetPrefixLng
- The length of the ASCII string containing the telephone
- network prefix.
-
- TeleNetPrefixPtr
- A pointer to the ASCII string containing the telephone
- network prefix. Both the pointer and the string can be
- null. This pointer is not examined unless the ConnectType
- is 2 (auto-dial). ASCII characters between X'00' and X'FF'
- are allowed in the string.
-
- TeleNetSuffixLng
- The length of the ASCII string containing the telephone
- network suffix.
-
- TeleNetSuffixPtr
- A pointer to the ASCII string containing the telephone
- network routing suffix. Both the pointer and the string can
- be null. This pointer is not examined unless the
- ConnectType is 2 (auto-dial). ASCII characters between
- X'00' and X'FF' are allowed in the string.
-
- TeleNumberLng
- The length of the ASCII string containing the telephone
- number.
-
- TeleNumberPtr
- A pointer to the ASCII string containing the telephone
- number. This pointer must point to a valid string for
- ConnectType2. This pointer is not examined unless the
- ConnectType is 2 (auto-dial). ASCII characters between
- X'00' and X'FF' are allowed in the string.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'02' Invalid parameter address.
-
- X'03' No connection exists.
-
- X'3B' Undefined input or output buffers.
-
- X'61' DCE hardware not responding.
-
- X'62' Invalid ConnectTimeout value.
-
- X'63' Data set ready (DSR) signal was not negated for at least
- 100 milliseconds.
-
- X'65' Call violates country requirements.
-
- X'66' Call attempt cannot be made.
-
- X'67' Time-out occurred.
-
- X'69' Physical port being used for a connection.
-
- X'6C' Requested connection time-out value violates network
- requirements.
-
- X'6D' Successful connection - switched. This return code
- returns only when ConnectType=4.
-
- X'6E' Successful connection - non-switched. This return code
- returns only when ConnectType=4.
-
- X'71' Requested function not supported.
-
- X'7B' Call collision occurred.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- ACDI sends the modem initialization command string to the modem prior
- to attempting to send the modem command string for ConnectTypes 0, 1,
- 2, and 3. This ensures that the proper line speed is set and that the
- modem is in a known state for receiving the connection command
- string.
-
- ACDI assembles an auto-dial command string and sends the string to
- the DCE when ConnectType=2 (auto-dial). This string is assembled as
- follows:
-
- 1. The first section of the string is the current dialing prefix
- string.
-
- 2. The second section of the string is the telephone network prefix
- string defined on this verb.
-
- 3. The third section of the string is the telephone number string
- defined on this verb. This portion of the verb is monitored in
- accordance with the parameters defined for the current country
- and network ID.
-
- 4. The fourth section of the string is the telephone network suffix
- string defined on this verb.
-
- 5. The final section of the string is the current dialing suffix
- string.
-
- After sending the dialing suffix string, ACDI monitors the received
- data and compares the data for reception of the valid connection
- response string. After detecting the string and determining that the
- physical circuit conditions are correct, ACDI returns a successful
- return code.
-
- Note: For further information on carriage control, see ComOpen
- (X'02').
-
- Each of the strings that make up the connect string can contain ASCII
- characters between X'00' and X'FF'. When the X'FF' character is
- encountered in the connect string, a 1-second pause is executed. This
- pause character is not transmitted to the DCE.
-
- ACDI does not allow a single process to own the port in two modes.
- Any application that utilizes port sharing by sharing the port with
- itself must have two separate processes: one for auto-answer mode
- and one for auto-dial mode.
-
- The thread is blocked until a time-out occurs, the requested
- connection is established, or an error situation is detected.
-
- Modification of telephone routing/number strings passed on ComConnect
- while this verb has not returned may cause unpredictable results.
-
- When a command string is sent to the data circuit-terminating
- equipment (DCE), a device carrier exchange time-out timer is started
- that runs out at the end of a user-defined time (default is 60
- seconds). If the ConnectTimeout timer has more time remaining than
- the device carrier exchange time-out timer, the attempt is
- terminated. The device carrier exchange time-out timer is used to
- ensure that the local and remote DCEs attain carrier-exchange status.
- This timer replaces the ConnectTimeout timer only if the
- ConnectTimeout timer has more time remaining.
-
- If the device carrier exchange time-out timer expires without the
- DCEs attaining carrier-exchange status, the following occurs:
-
- o For ConnectType=0, 1, or 2, ACDI disconnects and then returns an
- error (time-out occurred).
-
- o For ConnectType=3, ACDI disconnects and then returns to auto-answer
- mode with the ConnectTimeout timer running.
-
- The ConnectTimeout timer is not used for ConnectType=4. ACDI does not
- send command strings for this connect type.
-
- Note: In this version of ACDI, when ConnectType=4, you will receive
- a different indicator for a successful ComConnect.
-
- The application issues a ReturnCode X'6D' when a successful switched
- connection is accomplished for ConnectType=4 or a X'6E' when a
- successful non-switched connection is accomplished for ConnectType=4.
- These return codes give an application developer more information.
- When a connection is established for ConnectType=4, the connection
- cannot be broken except by the application issuing a ComDisconnect
- verb. When an application has established a data connection and the
- connection is lost, the application can continue to send commands to
- the DCE and begin a new data connection. This capability allows
- applications and users to establish multiple connections, reset
- errors, and test command combinations without having to reissue the
- ComConnect verb.
-
-
- ΓòÉΓòÉΓòÉ 7.3. ComDefInput (X'14') ΓòÉΓòÉΓòÉ
-
- ComDefInput (X'14')
-
- This verb defines the input buffer and input mode.
-
- Prerequisite Calls
-
- ComOpen
-
- Note: There can be no outstanding ComReadBlock or ComReadCharString
- verbs.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé INPUTBUFF Γöé X Γöé Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé INBUFFLENGTH Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé REMAININGDATAPTR Γöé Γöé X Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé REMAININGDATALGTH Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé REMAININGDATAERRS Γöé Γöé X Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé INPUTMODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé MODEDATA Γöé X Γöé Γöé Structure Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'14'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- InputBuff
- Starting address of the input buffer.
-
- InBuffLength
- The input buffer length in bytes.
-
- InputMode
- A value indicating either character, fixed-length block, or
- variable-length block mode.
-
- The valid input modes are:
-
- X'01' Character.
-
- X'02' Fixed-length block.
-
- X'03' Variable-length block.
-
- ModeData
- A data structure based on the character, fixed-length
- block, or variable-length block mode of the InputMode:
-
- o Character mode
-
- The data structure does not contain any useful data and is not
- examined.
-
-
- o Fixed-length block mode
-
- The data structure is as follows:
-
- BlkLength is a word-size variable the length of the fixed-length
- block. It is an unsigned integer with a minimum value of 2 and a
- maximum value of 65535.
-
-
- o Variable-length block mode
-
- The data structure is as follows:
-
- NumStrings is a byte-size variable that defines the number of
- end-of-data blocks. The range is 1 to 5.
-
- StringLgth is a byte-size variable that defines the length of
- the string in EOBString. The range is 1 to 4.
-
- EOBString is the end-of-block string. This is a 4-byte
- fixed-length, left-justified field. StringLgth bytes of this
- field are used as the end-of-block string. There can be 1 to 5
- of these strings. The number is defined in NumStrings.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'02' Invalid parameter address.
-
- X'3E' More than 128 blocks possible in buffer.
-
- X'3F' A read command is outstanding for this process.
-
- X'45' Data segment cannot be locked.
-
- X'49' Invalid input mode.
-
- X'4B' Invalid string length or number of strings.
-
- X'5C' Invalid block or buffer size.
-
- X'5D' Input buffer smaller than block size.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- RemainingDataPtr
- Address of data remaining in the previous input buffer.
- This is data that has not been previously returned to the
- application.
-
- RemainingDataLgth
- Length of data remaining in previous buffer.
-
- RemainingDataErrs
- Errors in data remaining in previous buffer. See
- ComReadBlock (X'19') for more information.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This function is to be used to define a new input buffer. If an input
- buffer has already been defined, this function unlocks the existing
- buffer and locks the new buffer.
-
- The maximum amount of data contained in the application input buffer
- at any time is 1 byte less than the total buffer size. ACDI reserves
- a floating byte at the logical end of the data in the buffer. The
- application input buffer size should be at least 1 byte larger than
- the fixed-length block size and at least 1 byte larger than the
- maximum variable-length block size (up to 65535 bytes). This
- establishes the minimum size at 2 bytes.
-
- No received data is queued prior to the input buffer being defined.
-
- The application defines the valid input mode: character mode,
- fixed-length block mode, or variable-length block mode.
-
- o In character mode, all data is assembled as a single character
- string and error information is tracked for the entire string. Use
- the ComReadCharString verb in this mode.
-
- o In fixed-length block mode, all data is assembled into fixed-sized
- blocks and error information is tracked for each block. Use the
- ComReadBlock verb in this mode.
-
- o In variable-length block mode, all data is assembled into
- variable-length blocks, which end in application defined strings.
- Up to five strings, up to 4 bytes each, can be defined as
- terminating strings. Error information is tracked for each block.
- Use the ComReadBlock verb in this mode.
-
- When the application redefines the input buffer, ACDI returns the
- location, length, and errors for any data in the old buffer that has
- not been returned to the application.
-
- The application cannot redefine the input buffer while either a
- ComReadCharString or a ComReadBlock verb is outstanding. If an
- attempt is made to redefine the input buffer, the ComDefInput verb
- returns an error indication.
-
- When the input buffer is redefined, any existing flow thresholds are
- reset to computed defaults. The application computes the defaults
- using the size of the new buffer. See ComRetFlowThresh (X'10') for a
- description of how the defaults are computed.
-
- The ComDefInput function can be called regardless of whether a link
- is connected and must be called before a connection is established.
-
- The BlkLength and EobString parameters are ignored in character mode.
- All EobString parameters are ignored in fixed-length block mode.
-
- If the BlkLength and InBuffLength parameters result in the
- possibility of more than 128 blocks existing in the input buffer, a
- warning return code is returned. However, the buffer size and block
- length remain as defined.
-
- When data being received in either fixed- or variable-length block
- mode causes more than 128 blocks of data to exist in the buffer, ACDI
- discards the incoming data as if no more space in the input buffer
- exists and an overflow event is posted. See ComReadEvent (X'13') for
- information on events queued.
-
- Note: ACDI calls the OS/2 base operating system to lock the
- application input buffer in the long-term lock area. The base
- operating system locks the entire data segment containing the
- input buffer in the long-term lock memory. To use your system
- resources most efficiently, allocate your application input
- buffer in its own data segment. One way to do this is to use
- the OS/2 command DosAllocSeg to allocate the space for your
- buffer.
-
-
- ΓòÉΓòÉΓòÉ 7.4. ComDefOutputBuff (X'16') ΓòÉΓòÉΓòÉ
-
- ComDefOutputBuff (X'16')
-
- This verb defines the application output buffer.
-
- Prerequisite Calls
-
- ComOpen
-
- Note: There can be no outstanding ComReadBlock verb, and all data
- must be transmitted.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé OUTPUTBUFF Γöé X Γöé Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé OUTBUFFLENGTH Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'16'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- OutputBuff
- The starting address of the output buffer.
-
- OutBuffLength
- The length (size) of the output buffer in bytes.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'02' Invalid parameter address.
-
- X'38' Cannot redefine the buffer; write request in progress.
-
- X'45' Buffer cannot be locked.
-
- X'4E' Buffer not empty.
-
- X'5C' Invalid buffer size.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- The maximum amount of data that can be contained in an asynchronous
- output buffer at any time is 1 byte less than the total buffer size.
- The output buffer size should be at least 1 byte larger than the
- maximum number of bytes to be written by a single ComWriteCharString
- verb.
-
- This function is used to define a new buffer. When issued, this
- function unlocks any existing output buffer and locks the new buffer.
-
- Note: ACDI calls the OS/2 base operating system to lock the
- application output buffer in the long-term lock area. The base
- operating system locks the entire data segment containing the
- output buffer in the long-term lock memory. To use your system
- resources most efficiently, allocate your application output
- buffer in its own data segment. One way to do this is to use
- the OS/2 command DosAllocSeg to allocate the space for your
- buffer.
-
-
- ΓòÉΓòÉΓòÉ 7.5. ComDisconnect (X'22') ΓòÉΓòÉΓòÉ
-
- ComDisconnect (X'22')
-
- This verb disconnects the asynchronous communications connection.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected or pending)
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'22'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'80' No on-hook indication from DCE.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- When the application issues this verb:
-
- o ACDI sends the hang-up string to the modem (DCE). This negates the
- request to send (RTS) and then negates the data terminal ready
- (DTR).
-
- o ACDI returns an error that indicates that the DCE did not
- disconnect from the line if data set ready (DSR) is not negated by
- the DCE 10 seconds after the DTR is negated.
-
- All of the I/O buffers are flushed as if the ComFlushInput and
- ComFlushOutput verbs had been called. ACDI logs the link statistics
- network management vector in the Communications Manager error log.
-
- The following verbs are unblocked if necessary and return with a
- return code X'03' (no connection exists):
-
- o ComWriteCharString
- o ComReadCharString
- o ComReadBlock
- o ComDrainOutput
- o ComConnect
-
-
- ΓòÉΓòÉΓòÉ 7.6. ComDrainOutput (X'1C') ΓòÉΓòÉΓòÉ
-
- ComDrainOutput (X'1C')
-
- This verb blocks the thread until the transmit output buffer is
- emptied.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
- ComDefOutputBuff
-
- Note: There can be no outstanding ComWriteCharString verbs.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DRAINTIMEOUT Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'1C'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- DrainTimeout
- Time to wait for the buffer to drain. This time-out is
- specified in increments of 10-millisecond units. The valid
- input values for this time-out are between 1 and 65535.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'37' Write request outstanding.
-
- X'3B' Undefined output buffer.
-
- X'53' Time-out exceeded while in XOFF state.
-
- X'54' Time-out exceeded while in XON state.
-
- X'62' Invalid time-out.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists. When an
- application calls ACDI with this verb, ACDI blocks or holds the
- application's thread of execution until the output buffer empties,
- the request times out, or a ComDisconnect verb is received by ACDI.
-
- If the application buffer does not empty in the specified amount of
- time and ACDI has received an XOFF from the remote sender, or the
- application has issued the ComStopTrans verb, this request returns
- with a return code of X'53'. A request that times out returns with a
- return code of X'54'.
-
- When using adapters containing UARTs with first-in-first-out (FIFO)
- buffers (16550A), ensure that line speed or line control values are
- changed. Use of the ComDrainOutput verb prior to these types of
- changes will alleviate this problem. This verb does not return while
- data is waiting in the transmit FIFO buffer. To use the
- ComDrainOutput:
-
- 1. Issue a ComWriteCharString verb.
-
- Make a change in either the bit rate or line speed.
-
- 2. Issue a ComDrainOutput verb.
-
- Make changes in line speed or line control values using a
- ComSetBitRate or a ComSetLineCtrl verb.
-
- 3. Issue your new ComWriteCharString verb.
-
-
- ΓòÉΓòÉΓòÉ 7.7. ComFlushInput (X'1A') ΓòÉΓòÉΓòÉ
-
- ComFlushInput (X'1A')
-
- This verb clears the application input buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComDefInput
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'1A'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'3B' Undefined input buffer.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- Any data in the application input buffer is cleared, and any
- outstanding read request is unblocked and returned to the application
- with a canceled return code. After this verb has completed
- successfully, new incoming data is queued at the start of the
- application input buffer.
-
-
- ΓòÉΓòÉΓòÉ 7.8. ComFlushOutput (X'1B') ΓòÉΓòÉΓòÉ
-
- ComFlushOutput (X'1B')
-
- This verb clears the application output buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComDefOutputBuff
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'1B'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device name.
-
- X'3B' Undefined output buffer.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb does not flush data pending from a ComTransImm verb or a
- pending XON or XOFF character. This verb cancels a break signal that
- is currently being transmitted. ACDI does not transmit any data that
- has been cleared from the application output buffer. Any blocked
- outstanding write request is unblocked and returned to the
- application with a canceled return code. The next available write
- pointer is reset to point to the beginning of the buffer when this
- verb has completed successfully.
-
- The application places any subsequent data to transmit at the
- beginning of the output buffer after this verb has completed
- successfully. This verb can be called regardless of whether a
- connection exists.
-
-
- ΓòÉΓòÉΓòÉ 7.9. ComGetLineInfo (X'25') ΓòÉΓòÉΓòÉ
-
- ComGetLineInfo (X'25')
-
- This verb returns information about the RS232-C circuits.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé INTERFACETYPE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CIRCUITS Γöé Γöé X Γöé Bits (16) Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'25'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- InterfaceType
- Identifies the type of interface your application is
- written for. Must be X'00' or X'01'.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- Circuits
- State of each of the signals.
-
- The Circuits are:
-
- Bit Meaning
-
- 0 Carrier detect signal status (0,1).
-
- 1 Data set ready signal status (0,1).
-
- 2 Clear to send signal status (0,1).
-
- 3 Data terminal ready (DTR) signal status (0,1).
-
- Other bits are reserved.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- An application issues this verb to find out whether the RS232-C
- carrier detect, data set ready, clear to send, and data terminal
- ready signals are asserted or negated.
-
-
- ΓòÉΓòÉΓòÉ 7.10. ComOpen (X'02') ΓòÉΓòÉΓòÉ
-
- ComOpen (X'02')
-
- This verb opens an asynchronous communications device and passes
- configuration information to ACDI.
-
- Prerequisite Calls
-
- None.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé Γöé SUPPLIED Γöé RETURNED Γöé Γöé
- Γöé PARAMETER NAME Γöé PARAMETER Γöé PARAMETER Γöé LENGTH Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé COMDEVNAME Γöé X Γöé Γöé Bytes (9) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FLAGS Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TELEPHONENETWORKID Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICETYPE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé AUTOANSDELDUR Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CAREXCHTIMEOUT Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DICMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CPCMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DSCMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé SCRESPSTRING Γöé X Γöé Γöé Bytes (24) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé UCRESPSTRING Γöé X Γöé Γöé Bytes (24) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé ICRESPSTRING Γöé X Γöé Γöé Bytes (24) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CFBUSYFLAGS Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CFWRONGNUMFLAGS Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CFOTHERFLAGS Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé CFRESPSTRING1- Γöé Γöé Γöé Γöé
- Γöé CFRESPSTRING8 Γöé X Γöé Γöé Bytes (24 each) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé AACMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HUCMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VOCMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VACMDSTRING Γöé X Γöé Γöé Bytes (256) Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VCRESPSTRING Γöé X Γöé Γöé Bytes (24) Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: The application must not already be opened by this function
- and must not be opened by more than one other process.
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'02'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- ComDevName
- An ASCII string that contains a base operating system
- character device name such as COM1. The length can be 8
- characters maximum (plus the X'00' terminator).
-
- The valid device names for ACDI are COM1, COM2, and COM3.
-
- Flags
- A group of flags that indicate configurable options. The
- flags are defined as follows:
-
- Bit Meaning
-
- 0 Type of line interface.
-
- OFF = Switched
- ON = Non-switched
-
- This bit is only valid when DeviceType = 9 (V.24).
-
- 1 Is DSR always asserted?
-
- OFF = No
- ON = Yes
-
- This bit is only valid when Device Type = 9 (V.24) and
- bit 0 is OFF (switched).
-
- 2 Does DTE or DCE do auto-answer delay?
-
- OFF = DTE
- ON = DCE
-
- 3 What is the auto-answer delay increment?
-
- OFF = Seconds
- ON = Rings
-
- 4 What command strings are to be used when the DeviceType
- value is other than 9?
-
- OFF = ACDI-supplied
- ON = User-supplied
-
- If ACDI-supplied is selected, the standard ACDI command
- strings for DeviceType are used. If user-supplied is
- selected, the command and response strings in the
- following parameters are used:
-
- o DICmdString
- o DPCmdString
- o SDCmdString
- o AACmdString
- o HUCmdString
- o VOCmdString
- o VACmdString
- o SCRespString
- o UCRespString
- o ICRespString
- o CFRespString1 through CFRespString8
- o VCRespString
-
- 5 Reserved. This bit must be OFF.
-
- 6 Reserved. This bit must be OFF.
-
- 7 Reserved. This bit must be OFF.
-
- 8 Reserved. This bit must be OFF.
-
- 9 Reserved. This bit must be OFF.
-
- 10 Reserved. This bit must be OFF.
-
- 11 Reserved. This bit must be OFF.
-
- 12 Reserved. This bit must be OFF.
-
- 13 Reserved. This bit must be OFF.
-
- 14 Reserved. This bit must be OFF.
-
- 15 Is configuration information being passed on this verb?
-
- OFF = No
- ON = Yes
-
- If this bit is OFF, bits 0 through 14 and the remaining
- parameters are ignored. The configuration information
- used by ACDI when this bit is OFF is found in the
- configuration file produced when the Asynchronous
- Communications Port Profiles were configured.
-
- TelephoneNetworkID
- This is the code for the country in which the program is to
- be run. For a list of telephone network IDs, refer to
- Configuration Guide.
-
- Note: If the specific country is not listed, choose a
- country that contains the same homologation
- requirements as the country in which the program is
- to run.
-
- DeviceType
- The type of DCE that is attached. DCEs that support the
- same command sets as the devices listed are also supported.
- The valid values are:
-
- 1 Hayes Smartmodem 1200 (AT command set)
-
- 2 Hayes Smartmodem 2400 (AT command set)
-
- 3 Hayes V-Series Modem Enhancer 1200 (AT command set)
-
- 4 Hayes V-Series Modem Enhancer 2400 (AT command set)
-
- 5 IBM Personal Computer Series (AT command set)
-
- 6 ROLMphone 244PC (AT command set)
-
- 7 MicroCom AX/2400C, AX/9624C (AT command set)
-
- 8 Racal-Vadic VI2422PA, VI2422S (V.25bis command set)
-
- 9 Other (V.24 circuits)
-
- AutoAnsDelDur
- The time that ACDI waits before answering the call.
-
- This delay increment is specified in bit 3 of the preceding
- Flags byte. The delay is ignored if bit 2 of the Flags byte
- is ON. Valid values are 0 through 255.
-
- CarExchTimeout
- The amount of time (in seconds) that ACDI waits for the
- modems to exchange carrier signals.
-
- Time begins when the modem goes off-hook, and time
- terminates when the modem asserts carrier detect (CD).
- Valid values are 1 through 255.
-
- DICmdString
- The device-initialization command string is composed of a
- 1-byte field followed by a 255-byte command string field.
-
- The command string sets the DCE into a known, initialized
- state. The command string is sent to the DCE whenever ACDI
- initializes the DCE.
-
- DPCmdString
- The dialing-prefix command string is composed of a 1-byte
- field followed by a 255-byte command string field.
-
- The command string navigates the call to a node in order to
- initialize the call. This command string is sent to the DCE
- when ACDI receives a ComConnect verb with ConnectType2
- (auto-dial).
-
- DSCmdString
- The dialing-suffix command string is composed of a 1-byte
- field followed by a 255-byte command string field.
-
- The command string completes the call navigation and
- signals the DCE to place the call. This command string is
- sent to the DCE when ACDI receives the ComConnect verb with
- ConnectType2 (auto-dial).
-
- SCRespString
- The successful command response string is composed of a
- 1-byte field followed by a 24-byte response string field.
-
- The response string notifies the DTE that the DCE has
- successfully executed the last command. The input data
- stream is monitored for this response each time a
- command-execution character (carriage return) is detected
- in the outgoing command. This response indicates that the
- DTE should proceed to the next command or continue sending
- the current command string.
-
- UCRespString
- The unsuccessful command response string is composed of a
- 1-byte length field followed by a 24-byte response string
- field.
-
- The response string notifies the DTE that the DCE has not
- successfully executed the last command. It is possible that
- the command or its parameters are not recognized or
- supported at this time. The input data stream is monitored
- for this response each time a command-execution character
- (carriage return) is detected in the outgoing command. This
- response indicates that the DTE may want to take
- alternative action.
-
- ICRespString
- The incoming-call response string is composed of a 1-byte
- length field followed by a 24-byte response string field.
-
- This response string notifies the DTE that the DCE has
- detected an incoming call or call attempt. The input data
- stream is monitored for this response each time ACDI goes
- into auto-answer mode (ConnectType3) and the DTE is
- configured as doing auto-answer delay (bit 2 of Flags is
- OFF).
-
- This response indicates that the DTE may want to instruct
- the DCE to go off-hook (answer the call) when the
- appropriate delay count is achieved (when the DTE is
- configured as doing the auto-answer delay).
-
- When the DCE is configured as doing the auto-answer delay
- (bit 2 of Flags is ON), this response is ignored. In the
- case of auto-dialing, this response is classified as an
- other-call response for homologation purposes. This
- response indicates that the DTE may want to take
- alternative action.
-
- CFBusyFlags
- Contains a flag for each of the call-failure response
- strings. Each flag indicates that the corresponding
- call-failure response string is a busy-number response from
- the DCE.
-
- This response string notifies the DTE that the DCE detected
- a busy signal for the remote DCE and that the call attempt
- was (usually) ended. The input data stream waits for this
- response each time an attempt is made to auto-dial.
-
- A bit that is ON indicates that the corresponding
- call-failure response string is to be treated as a busy
- response for homologation purposes.
-
- CFWrongNumFlags
- Contains a flag for each of the call-failure response
- strings that indicates that the corresponding call-failure
- response string is a wrong-number response from the DCE.
-
- This response string notifies the DTE that the DCE detected
- a wrong-number signal from the remote DCE that the call
- attempt was (usually) ended. The input data stream waits
- for this response each time an attempt is made to
- auto-dial.
-
- A bit that is ON indicates that the corresponding
- call-failure response string is to be treated as a wrong
- number for homologation purposes.
-
- CFOtherFlags
- Contains a flag for each of the call-failure response
- strings. Each flag indicates that the corresponding
- call-failure response string is another response from the
- DCE.
-
- This response string notifies the DTE that the DCE has
- failed to make a call because of a local condition or a
- time-out. The input data stream waits for this response
- each time an attempt is made to auto-dial.
-
- A bit that is ON indicates that the corresponding
- call-failure response string is to be treated as a busy
- response for homologation purposes.
-
- CFRespString1-8
- The call-failure response strings are composed of a 1-byte
- length field followed by a 24-byte response string field.
- The input data stream waits for these strings each time an
- attempt is made to auto-dial. Each string length is greater
- than 0.
-
- The call-failure flags specify the correct action for ACDI
- to take with respect to homologation enforcement for the
- string detected.
-
- AACmdString
- The auto-answer command string is composed of a 1-byte
- length field followed by a 255-byte command string field.
-
- This command string instructs the DCE to answer an incoming
- call after a specified period has elapsed since the first
- indication of the incoming call. This command string is
- sent to the DCE whenever ACDI receives a ComConnect verb
- with ConnectType3 and bit 2 of the Flags byte is set to ON
- (DCE does auto-answer delay).
-
- This string should contain the auto-answer delay
- programming for the DCE and is not used for V.25bis
- configurations.
-
- HUCmdString
- The hang-up command string is composed of a 1-byte length
- field followed by a 255-byte command string field.
-
- This command string instructs the DCE to terminate a call
- connection. It is sent to the DCE whenever ACDI receives a
- ComDisconnect verb and is not used for V.25bis
- configuration.
-
- VOCmdString
- The voice-to-data-originate command string is composed of a
- 1-byte length field followed by a 255-byte command string
- field.
-
- This command string instructs the DCE to go off-hook in
- originate frequency mode. It is sent to the DCE whenever
- ACDI receives a ComConnect verb with ConnectType0 (manually
- established connection with originate frequency).
- VOCmdString is not used for V.25bis configuration.
-
- VACmdString
- The voice-to-data-answer command string is composed of a
- 1-byte length field followed by a 255-byte command string.
-
- This command instructs the DCE to go off-hook in answer
- frequency mode. It is sent to the DCE:
-
- o After ACDI receives a ComConnect verb with ConnectType1
- (manually established connection with answer frequency)
-
- o After the delay specified by AutoAnsDelDur has occurred and bit
- 3 of the Flags byte is specified. ACDI receives a ComConnect
- verb with ConnectType3, and bit 2 of the Flags byte is set to 0
- (DTE does auto-answer delay).
-
- This string is not used for V.25bis configurations.
-
- VCRespString
- The valid-connection response string is composed of a
- 1-byte length field followed by a 24-byte response string
- field.
-
- This string provides ACDI with the standard response from
- the DCE that indicates a data connection has occurred.
- VCRespString is received in addition to the DSR and CD
- control signals. It is not used for V.25bis configurations.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'0B' Invalid device name.
-
- X'0C' Device cannot be opened.
-
- X'0D' ACDI device driver not installed.
-
- X'36' Device already opened.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- An application must issue this verb to obtain a communication port.
- ACDI returns a device handle for the port when the ComOpen verb is
- successful, and the application uses that handle on successive calls
- to ACDI. ACDI may then perform functions for a specific device that
- the application owns.
-
- Note: The word application refers to an OS/2 process. ACDI tracks
- resources for an application based on the OS/2 process ID of
- the application.
-
- Up to two processes may open a communication port as long as the user
- has not configured the port as Other modem or device. See
- Asynchronous Port Sharing for additional information.
-
- When a port is successfully opened, ACDI puts itself on the
- application's OS/2 exit list. See Application Exit List Processing
- for further information. Refer to OS/2 Technical Library for a
- description of the OS/2 exit list.
-
- When bit 15 of Flags is ON, ACDI assumes the application is passing
- configuration data on this verb. When this bit is OFF, ACDI assumes
- the application is to use the configuration defined by the user
- during Asynchronous Feature Configuration. For more information,
- refer to Configuration Guide.
-
- The configuration passed on this verb is valid until a ComClose verb
- is received.
-
- ACDI searches the telephony homologation file for an entry with the
- designated telephone network ID. If no entry is found, an error is
- returned. If an entry is found, it is used to validate the
- configuration parameters passed on this verb.
-
- When the command strings are passed to ACDI (bit 4 of Flags is ON),
- they replace the ACDI supplied strings. There is no facility in the
- interface for the application to pass less than the entire complement
- of strings.
-
- If command strings are defined in the DICmdString, String,
- DSCmdString, AACmdString, HUCmdString, VOCmdString, VACmdString,
- SCRespString, UCRespString, ICRespString, CFRespString1 through
- CFRespString8, and VCRespString parameters, and bit 4 of Flags is
- OFF, ACDI ignores the passed strings and retrieves the ACDI supplied
- strings for the specified device type.
-
- Command strings are allowed to be null. The length of the string
- structure should be set to 0 bytes to indicate a null string
-
- When a ComConnect verb is received by ACDI with ConnectType2
- (auto-dial), ACDI constructs a command string to send to the DCE as
- follows:
-
- o Dialing-prefix command string
- o Telephone-network-prefix command string from the ComConnect verb
- o Telephone-number string from the ComConnect verb
- o Telephone-network-suffix command string from the ComConnect verb
- o Dialing-suffix command string
-
- The purpose of the dialing-prefix and dialing-suffix command strings
- is to handle any special predialing requirements, such as selecting a
- modem from a modem pool, navigating through a CBX to a private
- network (such as a tie line) or navigating through a CBX to a public
- network (dialing 9 for outside). Once the navigation is completed,
- the telephone-network command strings instruct the DCE when the
- command string is connecting to another network such as MCI** or
- Sprint**. The dialing suffix normally contains only the
- begin-execution character (usually carrier return) to indicate to the
- DCE that it is to begin dialing the requested number.
-
- When a DCE or telephone network does not permit tone dialing, the
- DPCmdString should be modified to instruct the DCE to perform pulse
- dialing.
-
- Either process that is sharing the port may supply configuration
- information on the ComOpen verb.
-
- When the ComConnect verb for auto-dial from a second process is
- received by ACDI, the configuration in effect for the first process
- (the one allowing the port to be shared) is saved. When the
- ComDisconnect verb from the second process is received, the
- configuration for the first process is restored.
-
- Note: No attempt is made by ACDI to ensure the two configurations
- are compatible. It is the responsibility of the application
- and its users to make sure the proper hardware is attached to
- the port prior to an attempt to share the port between
- different devices.
-
- The arrangement of the command string and response string structures
- allows V.25bis users to allocate less memory for the strings than is
- required for ATtention-command-set users for this verb's control
- block. This occurs because the strings that are not valid for V.25bis
- are grouped at the end of the control block. While this seems awkward
- to ATtention-command-set users, it makes little or no difference to
- the application writer's implementation. The major advantage of this
- arrangement is that it saves approximately 1KB of memory allocation
- per port for the V.25bis user.
-
-
- ΓòÉΓòÉΓòÉ 7.11. ComReadBlock (X'19') ΓòÉΓòÉΓòÉ
-
- ComReadBlock (X'19')
-
- This verb reads a block of data from the input buffer and frees the
- block returned on the previous ComReadBlock.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected or auto-dial connection pending)
- ComDefInput
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILBLKPTR Γöé Γöé X Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILBLKLGTH Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READERRORMASK Γöé Γöé X Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'19'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'02' Invalid parameter address.
-
- X'03' No connection exists.
-
- X'33' Verb prematurely unblocked.
-
- X'3A' Verb canceled by the ComFlushInput verb.
-
- X'3B' Undefined input buffer.
-
- X'3C' The previous ComReadBlock verb still in progress.
-
- X'53' Time-out exceeded in XOFF state.
-
- X'54' Time-out exceeded in XON state.
-
- X'55' Terminated due to data error.
-
- X'57' Not valid in current input mode.
-
- X'5E' Input buffer is full.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- NextAvailBlkPtr
- The address of the next available block of data in the
- application input buffer.
-
- NextAvailBlkLgth
- The length of the block of data in the application input
- buffer.
-
- ReadErrorMask
- The types of errors detected that are being returned to the
- application in this block of data. Detected errors are
- defined as follows:
-
- Bit Meaning
-
- 0 Parity error.
-
- The hardware detected a parity error. At least one
- parity error is contained in the data being returned.
- Ensure that the correct parity type has been set. See
- ComSetLineCtrl (X'05') for a description of setting the
- data parity.
-
- 1 Framing error.
-
- The hardware detected a framing error. At least one
- framing error is contained in the data being returned.
- Ensure that the correct stop bits, data bits, and parity
- have been set. See ComSetLineCtrl (X'05') for a
- description of setting the number of stop bits and data
- bits.
-
- 2 Overrun error.
-
- The hardware detected an overrun error. At least one
- overrun error is contained in the data being returned.
- An overrun error is caused by a bit rate that prevents
- the system from processing an arriving byte of data
- before a new byte arrives. Two options are available to
- prevent this occurrence:
-
- o Decreasing the bit rate. See ComSetBitRate (X'04') for a
- description of setting the bit rate.
-
- o Decreasing the number of concurrent tasks.
-
- 3 Overflow error.
-
- At least one overflow error is contained in the data
- being returned. This error is caused by the application
- not removing data from the input buffer before the input
- buffer fills. The application should:
-
- o Read the buffer more often.
-
- o Enable automatic flow control. See ACDI Functions, Structure,
- and Verb Overview for a description of enabling automatic
- flow control.
-
- o Make the input buffer larger. See ComDefInput (X'14'), for a
- description of redefining the input buffer.
-
- o Lower the bit rate. See ComSetBitRate (X'04') for a
- description of setting the bit rate.
-
- 4-7 Reserved byte, not 0.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists. An application
- issues this verb to receive data when the input mode is fixed-length
- block mode or variable-length block mode.
-
- This verb informs ACDI that the application has processed the block
- returned on the previous ComReadBlock verb and that ACDI may use this
- free space to queue incoming data, if necessary. When ACDI returns
- this verb to the application, the NextAvailBlkPtr points to the next
- block of data in the buffer and the NextAvailBlkLgth contains the
- number of bytes in that block.
-
- The length of a block includes the end-of-block string for
- variable-length blocks. In variable-length block mode, end-of-block
- string detection is not performed, and any states in progress reset
- when any of the following occur:
-
- o The received data contains either a parity or framing error.
- o The received data creates either an overflow or overrun error.
- o The received data is a break.
-
- A line drop causes the read thread to be unblocked and returned to
- the calling application.
-
- If the application unblocks a blocked ComReadBlock verb with the
- ComUnblockThread verb, ACDI returns the ComReadBlock verb with 0's in
- the NextAvailBlkLgth and ReadErrorMask return parameters. In this
- case, the data remains in the buffer, but the application is not
- informed of this read.
-
- If error-character substitution has been enabled and if errors are
- detected, this function replaces the bad byte with the substitution
- character specified with the ComSetErrorCharSub verb. See
- ComSetErrorCharSub (X'1F') for additional information.
-
- ACDI sets the NextAvailBlkPtr return parameter to the beginning of
- the buffer, immediately after the buffer has been redefined or the
- data communication channel has been disconnected.
-
- The amount of data that ACDI queues in the application input buffer
- never exceeds the input buffer size minus 1 byte. ACDI reserves 1
- byte at the logical end of the data in the buffer at all times.
-
- Warning: Hardware defects in some UARTs might cause erroneous functions when
- used with the ACDI Personal Computer AT* device driver (ASYNCDDA.SYS). These
- defects cannot be compensated for in the device driver software. These
- problems exist in the INS 8250 and INS 8250-B asynchronous communication
- element (UART) manufactured by National Semiconductor** and in any internal
- modem UART that emulates these devices. However, the INS 8250-A device does
- not have these problems and appears as an INS 16450 to the device driver. The
- 8250-A is a member of the 8250 series UARTs.
-
- The following defects are known to exist:
-
- o The 8250 and 8250-B UARTs might transmit bad data when configured for 5 data
- bits and 1.5 stop bits. Although rarely used, this combination is not
- prohibited, and the data sent by these UARTs might not be valid with this
- setting.
-
- o The 8250 and 8250-B UARTs occasionally drop received characters without
- posting the receive overrun error flag. ACDI device drivers cannot detect
- data loss due to this hardware deficiency. To ensure accurate data, your
- application should implement error detection and correction protocols when
- using the 8250 and 8250-B UARTs.
-
- o The 8250 and 8250-B UARTs can transmit a single random character at
- power-on. The connected device (DCE) should not be expecting valid data from
- the DTE until data terminal ready (DTR) has been raised by ACDI.
-
-
- ΓòÉΓòÉΓòÉ 7.12. ComReadCharString (X'18') ΓòÉΓòÉΓòÉ
-
- ComReadCharString (X'18')
-
- This verb reads a character string and frees space previously
- occupied by input data.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected or auto-dial connection pending)
- ComDefInput
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BYTESFREED Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READBYTESNEEDED Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé INITIALWAIT Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILREADPTR Γöé Γöé X Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILREADLGTH Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READERRORMASK Γöé Γöé X Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'18'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- BytesFreed
- The number of characters that the application reads from
- the input buffer. ACDI may use this free space to queue new
- data.
-
- ReadBytesNeeded
- Indicates that at least this many characters should be in
- the application input buffer before ACDI returns the verb.
-
- InitialWait
- The number of seconds to wait before activating the
- intercharacter time-out. See ComSetTimeout (X'1D') for
- additional information. Values from 0 to 1952 indicate the
- number of seconds to wait before activating the
- intercharacter timer. Values from 1953 to 65534 are
- returned as an error. To obtain an infinite wait time, this
- value must be X'FFFF'.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'33' Verb unblocked.
-
- X'3A' Verb canceled by the ComFlushInput verb.
-
- X'3B' Undefined input buffer.
-
- X'3C' Previous ComReadCharString verb still in progress.
-
- X'52' The parameters for bytes needed is larger than the input
- buffer's usable space.
-
- X'53' Time-out occurred while in XOFF state.
-
- X'54' Time-out occurred while in XON state.
-
- X'57' Not valid in the current input mode.
-
- X'59' The parameters for bytes freed is larger than the number
- of characters returned on the previous ComReadCharString
- verb.
-
- X'62' Invalid initial wait time.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- NextAvailReadPtr
- Returned to the application and is the address of the next
- available character in the input buffer.
-
- NextAvailReadLgth
- The number of bytes available in the input buffer.
-
- ReadErrorMask
- A mask that defines the types of detected errors being
- returned to the application in this string. Detected errors
- are defined as follows:
-
- Bit Meaning
-
- 0 Parity error.
-
- The hardware detected a parity error. At least one
- parity error is contained in the data being returned.
- Ensure that the correct parity type has been set. See
- ComSetLineCtrl (X'05') for a description of setting the
- data parity.
-
- 1 Framing error.
-
- The hardware detected a framing error. At least one
- framing error is contained in the data being returned.
- Ensure that the correct number of stop bits and data
- bits has been set. See ComSetLineCtrl (X'05') for a
- description of setting the number of stop bits and data
- bits.
-
- 2 Overrun error.
-
- The hardware detected an overrun error. At least one
- overrun error is contained in the data being returned.
- An overrun error is caused by a bit rate that prevents
- the system from processing an arriving byte of data
- before a new byte arrives. Some options available to
- prevent this occurrence are:
-
- o Decreasing the bit rate. See ComSetBitRate (X'04') for a
- description of setting the bit rate.
-
- o Decreasing the number of concurrent tasks.
-
- 3 Overflow error.
-
- At least one overflow error is contained in the data
- being returned. This error occurs when the application
- does not remove data from the input buffer before the
- input buffer fills. The application should:
-
- o Read the buffer more often.
-
- o Enable automatic flow control. See Automatic Flow Control for
- a description of enabling automatic flow control.
-
- o Make the input buffer larger. See ComDefInput (X'14') for a
- description of redefining the input buffer.
-
- o Lower the bit rate. See ComSetBitRate (X'04') for a
- description of setting the bit rate.
-
- 4-7 Reserved byte, not 0.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can generally be used only while a connection exists. For
- auto-dial connections, this verb may be used while the connection is
- pending. This verb must be issued when the application is in
- character mode.
-
- This function is a request to ACDI to free characters (BytesFreed) in
- the input buffer and block the thread until ReadBytesNeeded data is
- available. When ACDI returns the verb, the NextAvailReadPtr parameter
- is set to point to all available characters, even if there are more
- characters than the application requested.
-
- If the connection drops or if the application issues a ComDisconnect
- verb, any blocked read thread unblocks and returns with an error
- condition (X'03').
-
- When this verb returns as a result of a ComUnblockThread verb,
- NextAvailReadLgth and ReadErrorMask are set to 0. In addition, this
- verb returns an error code that indicates that it was unblocked
- before it completed execution.
-
- If error-character substitution has been enabled and if an error is
- detected, this function replaces the bad byte with the substitution
- character specified with the ComSetErrorCharSub verb. See
- ComSetErrorCharSub (X'1F') for additional information.
-
- ACDI stops its InitialWait timer if one of the following conditions
- becomes true:
-
- o Time expires before receiving any data.
-
- o At least 1 byte of data arrives or is in the input buffer when this
- verb is received by ACDI.
-
- o Sufficient data in the buffer satisfies the request when this verb
- is received by ACDI.
-
- When a time-out occurs, the NextAvailReadPtr parameter points to the
- next available data byte in the input buffer, and the
- NextAvailReadLgth parameter is the number of characters received
- prior to the time-out. The ReadErrorMask parameter reflects the
- errors in all new characters being returned to the application on
- this ComReadCharString verb.
-
- ACDI sets the NextAvailReadPtr parameter to the first word of the
- buffer, immediately after the buffer has been redefined or the data
- communication channel has been disconnected.
-
- The amount of data that ACDI queues in the application input buffer
- never exceeds the input buffer size minus 1 byte. ACDI reserves 1
- byte at the logical end of the data in the buffer at all times.
-
- Warning: Hardware defects in some UARTs might cause erroneous
- functions when used with the ACDI Personal Computer AT device driver
- (ASYNCDDA.SYS). These defects cannot be compensated for in the device
- driver software. These problems exist in the INS 8250 and INS 8250-B
- UARTs manufactured by National Semiconductor and in any internal
- modem UART that emulates these devices. However, the INS 8250-A
- device does not have these problems and appears as an INS 16450 to
- the device driver. The 8250-A is a member of the 8250 series UARTs.
-
- The following defects are known to exist:
-
- o The 8250 and 8250-B UARTs might transmit bad data when configured
- for 5 data bits and 1.5 stop bits. Although rarely used, this
- combination is not prohibited, and the data sent by these UARTs
- might not be valid with this setting.
-
- o The 8250 and 8250-B UARTs occasionally drop the received characters
- without posting the receive overrun error flag. ACDI device drivers
- cannot detect data loss due to this hardware deficiency. To ensure
- accurate data, your application should implement error detection
- and correction protocols when using the 8250 and 8250-B UARTs.
-
- o The 8250 and 8250-B UARTs can transmit a single random character at
- power-on. The connected device (DCE) should not be expecting valid
- data from the DTE until data terminal ready (DTR) has been raised
- by ACDI.
-
-
- ΓòÉΓòÉΓòÉ 7.13. ComReadEvent (X'13') ΓòÉΓòÉΓòÉ
-
- ComReadEvent (X'13')
-
- This verb enables the communications event queue.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé SEMHANDLE Γöé X Γöé Γöé Doubleword Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BUFFERADDRESS Γöé X Γöé Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé EVENTMASKS Γöé X Γöé Γöé Doubleword Address Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'13'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- SemHandle
- The handle of a semaphore that is used by ACDI to signal
- the application to examine its event structure for an event
- notification.
-
- BufferAddress
- A far pointer to a data structure in the application's
- address space where the event information is placed. The
- data structure has the following format:
-
- EventType1 Bits (32)
-
- EventType2 Bits (32)
-
- Reserved Word
-
- EventMasks
- The address of a data structure in the application's data
- space that consists of two doublewords, called EventMask1
- and EventMask2. These masks correspond to EventType1 and
- EventType2, respectively. A 1 in a defined bit position
- enables notification of the event when it occurs.
-
- EventType1 is defined as follows:
-
- Bit Meaning
-
- 0 XON received.
-
- This event indicates that the XON character was
- received.
-
- 1 XOFF received.
-
- This event indicates that the XOFF character was
- received.
-
- 2 User stopped ACDI.
-
- This event, when enabled, is used to notify the
- application that the user has stopped ACDI from the
- Communications Manager Main Menu.
-
- 3 Hardware overrun error occurred.
-
- This event occurs if the hardware queue is full when new
- data is received by the hardware. If the input mode is
- fixed- or variable-length block mode, a hardware overrun
- event will be generated only once per block with
- multiple hardware overruns. Note that in any mode a
- hardware overrun event may correspond to several lost
- characters, depending on the time elapsed before the
- hardware was serviced.
-
- 4 Reserved.
-
- 5 Reserved.
-
- 6 Clear to send (CTS) asserted.
-
- 7 CTS negated.
-
- The preceding events, CTS asserted and CTS negated, are
- generated when the clear to send signal changes state.
-
- 8 Carrier detect (DCD) asserted.
-
- 9 DCD negated.
-
- The preceding events, DCD asserted and DCD negated, are
- generated when the carrier detect signal changes state.
- It is recommended that the application issue a
- ComDisconnect verb when the events indicate a line drop.
-
- 10 Data set ready (DSR) asserted.
-
- 11 DSR negated.
-
- The preceding events, DSR asserted and DSR negated, are
- generated when the data set ready signal changes state.
- It is recommended that the application issue a
- ComDisconnect verb when the events indicate a line drop.
-
- 12 Break signal received.
-
- This event is generated when a break signal is received
- and recognized by the hardware.
-
- 13 Reserved.
-
- 14 Application buffer overflow occurred.
-
- This event occurs if the input buffer is full when data
- needs to be moved into it. If the input mode is a fixed-
- or variable-length block mode, an application buffer
- overflow event is generated only once per block that
- contains multiple buffer overflow instances.
- Additionally, for any input mode, the event is generated
- only once per logical overflow. This event also occurs
- when data is received and 128 blocks of data already
- exist in the buffer.
-
- Note: ACDI maintains information for 128 blocks of data.
-
- 15 Data connection lost.
-
- This event occurs when ACDI determines that the data
- connection with the session partner is lost. The
- application should issue a ComDisconnect verb when
- notified of this event.
-
- 16-30 Reserved.
-
- 31 Event queue overrun occurred.
-
- ACDI maintains an internal event queue for each device
- opened through the ComOpen verb. Events are queued in
- this structure until the application is notified. This
- event is generated if events could not be queued
- properly and a queue overrun has occurred. The
- application is notified of this event before it is
- notified of any other events.
-
- EventType2 is reserved.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'02' Invalid parameter address.
-
- X'44' Invalid semaphore handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- An application initiates a request for event notification by calling
- the ComReadEvent verb once. It then receives notification of events
- by setting its semaphore and waiting for it to be cleared through the
- DosSemSetWait verb of the base operating system.
-
- When an event occurs, ACDI examines the semaphore to see if it has
- been set. If the semaphore is set, ACDI sets the appropriate bit in
- the applications event structure and clears the semaphore. Otherwise,
- ACDI queues this event and waits for the application to set the
- semaphore.
-
- Each time the semaphore is cleared by ACDI, the application should
- read the event information from the event structure, reset the
- semaphore, and wait for the semaphore to be cleared.
-
- To terminate event notification, the application issues a
- ComReadEvent verb with the two masks (EventMask1 and EventMask2) set
- to 0.
-
- Only a single ComReadEvent verb is active at any time.
-
- When a ComReadEvent verb is issued and a previous ComReadEvent verb
- is still in effect, the data buffer address and the semaphore handle
- of the newest ComReadEvent verb is used.
-
- Warning: The 8250 and 8250-B UARTs occasionally drop the received
- characters without posting the Receive Overrun error flag. ACDI
- device drivers cannot detect data loss due to this hardware
- deficiency.
-
-
- ΓòÉΓòÉΓòÉ 7.14. ComRetBitRate (X'06') ΓòÉΓòÉΓòÉ
-
- ComRetBitRate (X'06')
-
- This verb returns the bit rate for which the asynchronous
- communications hardware is programmed.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BITRATERCV Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BITRATESEND Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'06'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- BitRateRcv
- The receive bits per second (bps) value at which the
- asynchronous receiver operates.
-
- BitRateSend
- The transmit bits per second (bps) value at which the
- asynchronous transmitter operates.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- If your application has not issued the ComSetBitRate verb, this verb
- returns the default bit rate in both the BitRateRcv and BitRateSend
- parameters. The default speed is 1200 bps.
-
- The ComRetBitRate verb returns values as set by the the ComSetBitRate
- verb.
-
- Note: The return values may be different from the values set by your
- application, since some asynchronous communications hardware
- adjusts the bit rate for the communications environment.
-
-
- ΓòÉΓòÉΓòÉ 7.15. ComRetErrorCharSub (X'20') ΓòÉΓòÉΓòÉ
-
- ComRetErrorCharSub (X'20')
-
- This verb returns the current error-character substitution and mode.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé ERRORCHAR Γöé Γöé X Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé MODE Γöé Γöé X Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'20'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- ErrorChar
- The character to be substituted for invalid data when
- parity, framing, hardware overrun, or application buffer
- overflow errors are detected.
-
- Mode
- An integer that specifies whether substitution is enabled
- (1) or disabled (0).
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- See ComSetErrorCharSub (X'1F') for a description of the default
- settings and error-character substitution.
-
-
- ΓòÉΓòÉΓòÉ 7.16. ComRetFlowChar (X'0E') ΓòÉΓòÉΓòÉ
-
- ComRetFlowChar (X'0E')
-
- This verb returns flow control XOFF and XON characters.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XONCHAR Γöé Γöé X Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XOFFCHAR Γöé Γöé X Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0E'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- XOnChar
- The XON character.
-
- XOffChar
- The XOFF character.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- The current values for the flow control characters are returned. See
- ComSetFlowChar (X'0B') for the definition of the parameters and
- processing.
-
- If an application has not previously issued the ComSetFlowChar verb
- to change the flow control characters, the following defaults are
- returned:
-
- ACDI returns values even if the application has not enabled automatic
- flow control. ACDI uses these returned values to detect XON and XOFF
- characters in the incoming data to generate communications events.
-
-
- ΓòÉΓòÉΓòÉ 7.17. ComRetFlowMode (X'0F') ΓòÉΓòÉΓòÉ
-
- ComRetFlowMode (X'0F')
-
- This verb returns information specifying whether automatic flow
- control is enabled.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FLOWMODE Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0F'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- FlowMode
- The following identifies the flow control mode:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé MODE Γöé FLOW CONTROL Γöé DELETE XON Γöé DELETE XOFF Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Off Γöé No Γöé No Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé On Γöé Yes Γöé Yes Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- FlowMode=0 is the default (when automatic flow control is off), and
- both the XON and XOFF characters are left in the data stream when
- received.
-
- Note: When using the default choice, there is no requirement that
- buffer levels must have been previously specified since none
- are used.
-
- See ComSetFlowThresh (X'0D') for additional information.
-
- Comments
-
- When automatic flow control is enabled, XON and XOFF characters are
- consumed by ACDI and are not placed into the application input
- buffer.
-
- Applications that do not use automatic flow control often implement
- their own flow control at the application level (for example,
- implementations of frame-level protocols).
-
- Note: Frame-level protocols may use flow control packets instead of
- flow control characters.
-
-
- ΓòÉΓòÉΓòÉ 7.18. ComRetFlowThresh (X'10') ΓòÉΓòÉΓòÉ
-
- ComRetFlowThresh (X'10')
-
- This verb returns flow control threshold levels for the application
- input buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComDefInput
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XOFFBUFFLEVEL Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XONBUFFLEVEL Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'10'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'3B' Undefined input buffer.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- XOffBuffLevel
- The amount of free space in the application input buffer
- where the XOFF character is sent. It is an unsigned
- integer.
-
- XOnBuffLevel
- The amount of free space in the application input buffer
- where the XON is sent. It is an unsigned integer.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- See ComSetFlowThresh (X'0D') for a description of flow control
- threshold levels.
-
- If an application has not issued the ComSetFlowThresh verb, ACDI
- returns the default threshold levels that were calculated when the
- application defined its input buffer with the ComDefInput verb.
-
- The default XON threshold level is calculated as 80% of the
- application buffer size. The default XOFF buffer length is calculated
- as 20% of the application buffer size.
-
-
- ΓòÉΓòÉΓòÉ 7.19. ComRetLineCtrl (X'07') ΓòÉΓòÉΓòÉ
-
- ComRetLineCtrl (X'07')
-
- This verb returns the current line control values for which the
- asynchronous receiver/transmitter hardware is programmed.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé STOPBITS Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé PARITY Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DATABITS Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'07'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- StopBits
- Indicates the number of stop bits used by the asynchronous
- communications hardware for transmitting and receiving
- data.
-
- Parity
- Indicates the parity used by the asynchronous
- communications hardware for transmitting and receiving
- data.
-
- DataBits
- Indicates the number of data bits used by the asynchronous
- communications hardware for transmitting and receiving
- data.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- See ComSetLineCtrl (X'05') for a description of the values that are
- returned for stop bits, parity, and data bits.
-
- If the application has not issued the ComSetLineCtrl verb, this verb
- returns the default line control parameters (1 stop bit, even parity,
- and 7 data bits).
-
-
- ΓòÉΓòÉΓòÉ 7.20. ComRetTimeout (X'1E') ΓòÉΓòÉΓòÉ
-
- ComRetTimeout (X'1E')
-
- This verb returns time-out values for the ComReadCharString,
- ComReadBlock, and ComWriteCharString verbs.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READTIMEOUTBLOCK Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READTIMEOUTCHAR Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé WRITETIMEOUT Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- ReadTimeoutBlock
- Time-out value used for timing the ComReadBlock verb.
-
- ReadTimeoutChar
- Time-out value used for timing the ComReadCharString verb.
-
- WriteTimeout
- Time-out value used for timing the ComWriteCharString verb.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This call can be made regardless of whether a data connection exists.
- See ComSetTimeout (X'1D') for a description of the time-out
- parameters and additional information.
-
-
- ΓòÉΓòÉΓòÉ 7.21. ComSendBreak (X'11') ΓòÉΓòÉΓòÉ
-
- ComSendBreak (X'11')
-
- This verb sends a break signal for the user-specified duration.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé MINDURATION Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'11'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- MinDuration
- Duration of break signal expressed as an integer specifying
- 50-millisecond units.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'40' Invalid duration.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This function should be issued only when a connection has been
- established. This verb instructs ACDI to generate a break signal. The
- break signal is issued for the duration specified and is generated
- immediately, even if transmission is currently suspended because of
- XOFF.
-
- The minimum value is 1 (50 milliseconds) and the maximum value is 255
- (in multiples of 50 milliseconds). This value is rounded up by ACDI
- to the smallest integer multiple of the interrupt clock period (for
- the particular machine that is running the program) that is larger
- than the time indicated.
-
-
- ΓòÉΓòÉΓòÉ 7.22. ComSetBitRate (X'04') ΓòÉΓòÉΓòÉ
-
- ComSetBitRate (X'04')
-
- This verb sets the bit rate of the asynchronous receiver/transmitter
- on the asynchronous communications hardware.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BITRATERCV Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BITRATESEND Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'04'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- BitRateRcv
- The receive bits per second (bps) value at which the
- asynchronous receiver operates.
-
- BitRateSend
- The transmit bits per second (bps) value at which the
- asynchronous transmitter operates.
-
- The following values for bit rate correspond to the maximum
- bit rates that ACDI will program on the asynchronous
- receiver/transmitter or the asynchronous adapter hardware:
-
- X'0001' 50 bps
-
- X'0002' 75 bps
-
- X'0003' 110 bps
-
- X'0004' 134.5 bps
-
- X'0005' 150 bps
-
- X'0006' 200 bps
-
- X'0007' 300 bps
-
- X'0008' 600 bps
-
- X'0009' 1200 bps
-
- X'000A' 1800 bps
-
- X'000B' 2000 bps
-
- X'000C' 2400 bps
-
- X'000D' 3600 bps
-
- X'000E' 4800 bps
-
- X'000F' 7200 bps
-
- X'0010' 9600 bps
-
- X'0011' 19200 bps
-
- X'0012' 38400 bps
-
- X'0013' 48000 bps
-
- X'0014' 56000 bps
-
- X'0015' 57600 bps
-
- X'0016' 64000 bps
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'14' Bit rate not supported.
-
- X'17' Undefined bit rate.
-
- X'2A' Transmit and receive speeds must be identical.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- Speeds other than those shown for ComSetBitRate are unsupported, and
- you receive a return code X'17' (undefined bit rate). The
- ComSetBitRate verb supports line speeds up to 64K bps. Dissimilar
- transmit and receive speeds are supported only if one speed is
- exactly 16 times faster than the other speed. If a device cannot
- support dissimilar transmit and receive speeds, a return code
- (transmit and receive speed must be the same for this device) is
- returned.
-
- A default bit rate or line speed of 1200 bps is set when a
- communication port is opened. If a device cannot support the rate
- requested, ACDI does not default to another rate. An error condition
- is returned by ACDI.
-
- Setting the bit rate is a function different from the other line
- characteristics since most devices cannot change this rate once a
- data connection is established. This command is generally issued
- prior to establishing data connection. The device driver issues an
- error if it cannot change the bit rate when the call is issued.
-
- Support of a specific line speed is dependent on the device driver
- that is installed at the time. If the installed device driver does
- not support a speed previously listed, a return code (undefined bit
- rate) is returned.
-
- If you specify X'00' or X'01' in the Version parameter, all bit rates
- up to and including 9600 bps are valid. If you specify X'02' or X'03'
- in the Version parameter, all bit rates up to and including 19200 bps
- are valid. If you specify X'04' in the Version parameter, all bit
- rates up to and including 64000 bps are valid.
-
- Note: To obtain line speeds unavailable on versions X'00', X'01',
- X'02', or X'03', ComSetBitRate must use version X'04'.
-
- Use this verb to set the communications bit rate before establishing
- a connection. If the BitRateRcv and BitRateSend parameters are the
- same for particular hardware, the return code X'2A' is returned.
-
- When you use adapters containing UARTs with FIFO buffers (16550A),
- take care when changing line speeds or line control values. For
- example, use of the ComDrainOutput verb prior to these types of
- changes alleviates a potential overflow problem.
-
- Note: If you use a modem to establish a connection, see Bit Rate and
- Line Control Parameters for information.
-
-
- ΓòÉΓòÉΓòÉ 7.23. ComSetErrorCharSub (X'1F') ΓòÉΓòÉΓòÉ
-
- ComSetErrorCharSub (X'1F')
-
- This verb sets the error-character substitution mode and error
- substitution character.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé ERRORCHAR Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé MODE Γöé X Γöé Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'1F'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- ErrorChar
- The character to be substituted for error data when parity,
- framing, hardware overrun, or application buffer overflow
- errors occur.
-
- Mode
- An integer that specifies whether error-character
- substitution is enabled or disabled. A value of 0 enables
- substitution. Any other value disables error-character
- substitution.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- When error-character substitution is enabled, ACDI replaces an
- incoming character that has a parity or framing error with the error
- substitution character.
-
- Also, when a hardware overrun error occurs, ACDI inserts the error
- substitution character in the input buffer to mark the spot where a
- character or characters were lost.
-
- If the application input buffer overflows, ACDI replaces the last
- character received in the buffer with the error substitution
- character.
-
- If ComSetErrorCharSub has never been called, error-character
- substitution is disabled.
-
-
- ΓòÉΓòÉΓòÉ 7.24. ComSetFlowChar (X'0B') ΓòÉΓòÉΓòÉ
-
- ComSetFlowChar (X'0B')
-
- This verb sets flow control (XON and XOFF) characters.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XONCHAR Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XOFFCHAR Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0B'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- XOnChar
- The XON character.
-
- XOffChar
- The XOFF character.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can be issued to change the XON and XOFF characters that
- ACDI uses for automatic flow control. See Flow Control for a
- description of how ACDI manages flow control for an application.
-
- The current line control parameters set on the asynchronous
- communications hardware affect both the XON and XOFF characters.
-
- For example, if you have programmed the asynchronous communications
- hardware for 7 data bits, only the lower 7 data bits of your XOFF
- character are sent when ACDI recognizes that an XOFF needs to be
- sent.
-
- The default values for the flow control characters are:
-
-
- ΓòÉΓòÉΓòÉ 7.25. ComSetFlowMode (X'0C') ΓòÉΓòÉΓòÉ
-
- ComSetFlowMode (X'0C')
-
- This verb sets the flow control (XON and XOFF) mode.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé FLOWMODE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0C'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- FlowMode
- Enables/disables automatic flow control.
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé MODE Γöé FLOW CONTROL Γöé DELETE XON Γöé DELETE XOFF Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Disables Γöé No Γöé No Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé Enables Γöé Yes Γöé Yes Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'49' FlowMode invalid.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- FlowMode=0 is the default (automatic flow control is off), and both
- the XON and XOFF characters are left in the data stream when
- received.
-
- Note: For this default choice, there is no requirement that buffer
- levels must be previously specified, since none are used. See
- ComSetFlowThresh (X'0D') for additional information.
-
- When automatic flow control is enabled, XON and XOFF characters are
- consumed by ACDI. and are not placed into the application input
- buffer.
-
- Applications that choose not to turn on automatic flow control often
- implement their own flow control at the application level (for
- example, implementations of frame-level protocols).
-
- Note: Frame-level protocols may use flow control packets instead of
- flow control characters.
-
- Warning: The application writer should be careful enabling this
- feature when the input mode is block mode. XON and XOFF characters
- can exist in the block mode I/O data stream used by frame-level
- protocols. Also, detection of those characters in the data stream
- with automatic flow control enabled can put the data flow into a
- deadlocked state.
-
-
- ΓòÉΓòÉΓòÉ 7.26. ComSetFlowThresh (X'0D') ΓòÉΓòÉΓòÉ
-
- ComSetFlowThresh (X'0D')
-
- This verb sets the flow control threshold levels for the application
- input buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComDefInput
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XOFFBUFFLEVEL Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé XONBUFFLEVEL Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0D'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- XOffBuffLevel
- The amount of free space in the application input buffer
- where the XOFF character is sent. It is an unsigned
- integer.
-
- XOnBuffLevel
- The amount of free space in the application input buffer
- where the XON is sent. It is an unsigned integer.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'39' Specified XOFF buffer level is greater than or equal to
- the XON buffer level.
-
- X'3B' Undefined application input buffer.
-
- X'3D' Invalid buffer level. This error can be caused by
- setting the XON buffer to a greater value than the
- application input buffer.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- Buffer levels are expressed as the number of free bytes in the
- application input buffer. When the number of free characters (free
- space) in the application input buffer becomes less than the
- specified XOFF level, ACDI sends the XOFF character. When the number
- of free characters (free space) becomes larger than the specified XON
- level, ACDI sends an XON character to the remote sender.
-
- The XOFF level must be set to less than the XON level. Setting the
- XOFF level equal to or greater than XON returns an error condition.
-
- The application must use the ComSetFlowMode verb to enable automatic
- flow control and activate these flow control threshold levels.
-
- Note: The XON and XOFF thresholds should be far enough apart to
- avoid unnecessary oscillation between the XON state and the
- XOFF state.
-
-
- ΓòÉΓòÉΓòÉ 7.27. ComSetLineCtrl (X'05') ΓòÉΓòÉΓòÉ
-
- ComSetLineCtrl (X'05')
-
- This verb sets the line control values for the asynchronous
- receiver/transmitter on the asynchronous communications hardware.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé STOPBITS Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé PARITY Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RESERVED Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DATABITS Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'05'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- StopBits
- Indicates the number of stop bits to be used by the
- asynchronous transmitter and receiver circuits for encoding
- the character.
-
- X'01' 1 stop bit.
-
- X'02' 1.5 stop bits (valid only with 5 data bits).
-
- X'03' 2 stop bits (not valid with 5 data bits).
-
- Parity
- Indicates the parity to be used for each character encoding
- on transmission and integrity testing on reception.
-
- X'00' No parity.
-
- X'01' Odd parity.
-
- X'02' Even parity.
-
- X'03' Mark parity.
-
- X'04' Space parity.
-
- DataBits
- Indicates the number of data bits for each character
- encoding.
-
- X'05' 5 data bits (not valid with 2 stop bits).
-
- X'06' 6 data bits.
-
- X'07' 7 data bits.
-
- X'08' 8 data bits.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'2D' Invalid number of stop bits.
-
- X'2F' Invalid parity.
-
- X'31' Invalid number of data bits.
-
- X'32' Line control settings not compatible.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- The defaults set by the system when the device is obtained with the
- ComOpen verb are 7 data bits, 1 stop bit, and even parity mode.
-
- If you use a mode to establish a connection, see Bit Rate and Line
- Control Parameters for additional information.
-
- When you use adapters containing UARTs with FIFO buffers (16550A),
- take care to change line speeds or line control values. Use of the
- ComDrainOutput verb prior to these types of changes alleviates this
- problem.
-
- Warning: The 8250 and 8250-B UARTs might transmit bad data when
- configured for 5 data bits and 1.5 stop bits. Although rarely used,
- this combination is not prohibited and the data sent by these UARTs
- might not be valid with this setting.
-
-
- ΓòÉΓòÉΓòÉ 7.28. ComSetTimeout (X'1D') ΓòÉΓòÉΓòÉ
-
- ComSetTimeout (X'1D')
-
- This verb sets time-out values for the ComReadCharString,
- ComReadBlock, and ComWriteCharString verbs.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READTIMEOUTBLOCK Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé READTIMEOUTCHAR Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé WRITETIMEOUT Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'1D'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- ReadTimeoutBlock
- Specifies the time in 10-millisecond units to complete the
- read operation of the ComReadBlock verb for the entire
- block prior to timing out. A value of 0 results in an
- infinite time-out. This value is rounded up by ACDI to the
- smallest integer multiple of the interrupt clock period
- (for the particular machine that is running the program)
- that is larger than the minimum time indicated. The range
- is 0 to 65535. The system may extend this time.
-
- ReadTimeoutChar
- Specifies the maximum time requested by the application to
- be allowed between the characters being received in
- character mode, before a time-out is generated. Values from
- 1 to 8192 indicate the maximum number of character times
- (at the current line speed and character specification)
- that can elapse (after the InitialWait time has expired)
- between received characters before a time-out error is
- returned on a ComReadCharString verb. A value of 0 results
- in an infinite time-out. Values greater than 8192 return an
- error.
-
- WriteTimeout
- Specifies the time in 10-millisecond units to wait for
- WriteBytesNeeded to become available before a time-out is
- generated on a ComWriteCharString verb.
-
- Returned Parameters
-
- ReturnCode
- Returns the successful completion of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'62' Invalid time-out.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This call can be made regardless of whether a data connection exists.
-
- The ReadTimeoutBlock, ReadTimeoutChar, and WriteTimeout timers are
- activated when a read or write request is routed by ACDI to the
- device driver. These timers are not suspended by flow control. For
- example, the ComWriteCharString timer is not suspended when the
- remote transmitter sends an XOFF.
-
- Defaults are as follows:
-
- o ReadTimeoutBlock = 5 (50 milliseconds)
- o ReadTimeoutChar = 5 (5 character times)
- o WriteTimeout = 5 (50 milliseconds)
-
- The ReadTimeoutChar timer is reset and restarted each time a
- character is received.
-
-
- ΓòÉΓòÉΓòÉ 7.29. ComStartTrans (X'0A') ΓòÉΓòÉΓòÉ
-
- ComStartTrans (X'0A')
-
- This verb instructs ACDI to start transmitting data in the
- application output buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
-
- Note: Automatic flow control must not be enabled.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'0A'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'35' Automatic flow control in progress.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists, and it
- instructs ACDI to resume data transmission. It has no effect if data
- transmission is not suspended.
-
- This verb cannot be used while automatic flow control is enabled.
-
- Note: It is not necessary to issue this verb to start data
- transmission in general. This verb is only used if an
- application has previously issued a ComStopTrans verb.
-
-
- ΓòÉΓòÉΓòÉ 7.30. ComStopTrans (X'09') ΓòÉΓòÉΓòÉ
-
- ComStopTrans (X'09')
-
- This verbs instructs ACDI to stop transmitting data in the
- application buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
-
- Note: Automatic flow control must not be enabled.
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'09'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'35' Automatic flow control in progress.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists.
-
- Characters transmitted with the ComTransImm verb and transmission of
- a break signal with the ComSendBreak verb are not prohibited by this
- verb.
-
- This verb cannot be used while automatic flow control is enabled.
-
-
- ΓòÉΓòÉΓòÉ 7.31. ComTransImm (X'08') ΓòÉΓòÉΓòÉ
-
- ComTransImm (X'08')
-
- This verb sends the specified character immediately.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé TRANSCHAR Γöé X Γöé Γöé Byte Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'08'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- TransChar
- Contains 1 byte to be transmitted immediately.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'3C' Previous ComTransImm verb still in progress.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists.
-
- When this verb is issued, ACDI transmits the TransChar byte of data
- immediately if a connection is established and if ACDI is not
- currently sending a break signal.
-
- The verb is typically used to send an XON and XOFF character for
- application control of data flow.
-
- The character is transmitted with the current line control setting
- for data bits. For example, if the current data bit setting is 7,
- only the lower 7 bits of the character are sent out over the line.
-
- Note: ACDI does not monitor the values of the TransChar parameter
- when the ComTransImm function is issued. If the port has
- automatic flow control enabled, this function should not be
- used to send XON and XOFF characters. Doing so may cause ACDI
- to get out of sync with the remote sender's transmission
- state.
-
-
- ΓòÉΓòÉΓòÉ 7.32. ComUnblockThread (X'26') ΓòÉΓòÉΓòÉ
-
- ComUnblockThread (X'26')
-
- This verb unblocks the specified thread if it is currently blocked.
-
- Prerequisite Calls
-
- ComOpen
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé UNBLOCKMASK Γöé X Γöé Γöé Bits (32) Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'26'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- UnblockMask
- Specifies the thread or threads to be unblocked.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'38' One of the specified threads was not blocked.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- If bit 0 of the unblock mask is set, ACDI unblocks any thread that
- has issued a ComReadCharString verb (if one is blocked).
-
- If bit 1 is set, ACDI unblocks any thread that has issued a
- ComReadBlock verb (if one is blocked).
-
- Note: When the blocked read request returns, it returns a 0 in the
- data length field and the error mask field. The return code
- indicates the request was canceled by a ComUnblockThread verb.
-
-
- ΓòÉΓòÉΓòÉ 7.33. ComWriteCharString (X'17') ΓòÉΓòÉΓòÉ
-
- ComWriteCharString (X'17')
-
- This verb writes new data in the application output buffer and
- returns updated free space in the buffer.
-
- Prerequisite Calls
-
- ComOpen
- ComConnect (must be connected)
- ComDefOutputBuff
-
- Verb Control Block Format
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé FUNCTIONCODE Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé VERSION Γöé X Γöé Γöé Byte Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURNCODE Γöé Γöé X Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé DEVICEHANDLE Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé BYTESWRITTEN Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé WRITEBYTESNEEDED Γöé X Γöé Γöé Word Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILWRITEPTR Γöé Γöé X Γöé Doubleword Address Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé NEXTAVAILWRITELGTH Γöé Γöé X Γöé Word Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Supplied Parameters
-
- FunctionCode
- Defines the function to be performed. Must be X'17'.
-
- Version
- Identifies the version of ACDI your application is written
- for. Must be X'00', X'01', X'02', X'03', or X'04'.
-
- DeviceHandle
- Returned by the ComOpen verb; identifies the device to
- ACDI.
-
- BytesWritten
- Is the number of characters put into the application output
- buffer by the application. ACDI writes these to the device.
-
- WriteBytesNeeded
- Is the number of bytes that should be available in the
- application output buffer before ACDI returns control to
- the application.
-
- Returned Parameters
-
- ReturnCode
- Returns the completion status of the verb.
-
- The following values can be returned:
-
- X'00' Successful.
-
- X'01' Invalid device handle.
-
- X'03' No connection exists.
-
- X'37' Verb canceled by ComFlushOutput verb.
-
- X'3B' Undefined output buffer.
-
- X'3C' A ComWriteCharString verb is already in progress.
-
- X'51' The number specified in the BytesWritten parameter is
- larger than the available space in the output buffer.
-
- X'52' The number of bytes needed is larger than the output
- buffer's usable space.
-
- X'53' Time-out exceeded while in XOFF state.
-
- X'54' Time-out exceeded while in XON state.
-
- X'F1' Base operating system error occurred during execution.
-
- X'F4' Invalid version of ACDI.
-
- X'FF' ACDI not started.
-
- NextAvailWritePtr
- Is returned to the application and is the address of the
- next available byte of free space in the application output
- buffer.
-
- NextAvailWriteLgth
- Is the length of the free space area in the application
- output buffer.
-
- For more information, see ACDI Return Codes.
-
- Comments
-
- This verb can only be used while a connection exists.
-
- An application issues a ComWriteCharString verb to inform ACDI that
- BytesWritten characters have been added to the application output
- buffer for ACDI to transmit. The application makes a request for free
- space in the output buffer. ACDI blocks the application's thread
- until the free space is available in the buffer or until the request
- times out (as with the WriteTimeout parameter set by the
- ComSetTimeout verb).
-
- The first time an application copies data, it should copy the data
- into the buffer starting at the beginning of the buffer.
- Subsequently, the application can copy data into the buffer beginning
- at the pointer. This frees space returned to the application by ACDI
- on the previous ComWriteCharString verb.
-
- If a connection drops while a ComWriteCharString verb is outstanding,
- ACDI unblocks the request and returns it to the application.
-
- If the application issues the ComWriteCharString verb with a
- BytesWritten value that is larger than or equal to the output buffer
- size, ACDI returns an error code of X'51'. ACDI then flushes the
- output buffer. After receiving the X'51' return code, the application
- should copy subsequent data for ACDI to transmit at the beginning of
- the output buffer.
-
- If the ComWriteCharString verb times out (enough free space does not
- become available in the time specified by the WriteTimeout parameter)
- and ACDI has received an XOFF character from the remote receiver or
- the application has issued the ComStopTrans verb, ACDI returns the
- verb with the X'53' return code. Otherwise, the X'54' return code is
- returned by ACDI when the request times out.
-
- Note: When a request times out, ACDI continues to transmit the data
- in the application output buffer.
-
-
- ΓòÉΓòÉΓòÉ 8. Using the ACDI Redirection API ΓòÉΓòÉΓòÉ
-
- ACDI Redirection allows you to redirect ACDI using an application program.
- Using ACDI Redirection, you can set and query ACDI by interfaces other than a
- command line. For example, an ACDI application program can determine if a port
- is currently redirected.
-
- This chapter describes how to use the ACDI Redirection application programming
- interface (API) and provides a detailed description of the six ACDI Redirection
- API functions.
-
-
- ΓòÉΓòÉΓòÉ 8.1. ACDI Redirection API Functions ΓòÉΓòÉΓòÉ
-
- The ACDI Redirection API consists of the following six functions:
-
- o ArfCreate
- o ArfQuery
- o ArfRedirect
- o ArfRestore
- o ArfSave
- o ArfUnRedirect
-
- These functions are discussed in detail in this chapter. For a detailed
- explanation of the return codes for these functions, see ACDI Redirection API
- Return Codes.
-
-
- ΓòÉΓòÉΓòÉ 8.2. ArfCreate ArfCreate function ΓòÉΓòÉΓòÉ
-
- ArfCreate
-
- This function creates a redirection configuration data file named
- ACSARF.DAT.
-
- ArfCreate()
-
- Supplied Parameters
-
- None.
-
- Returned Parameters
-
- None.
-
- Return Codes
-
- The following codes are valid for ArfCreate:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé Communications Manager not started Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 9 Γöé Error accessing file ACSARF.DAT Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 10 Γöé File ACSARF.DAT already exists Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: If ACSARF.DAT is accidentally erased, this function can be
- used to create a new one. ArfCreate creates a redirection
- configuration data file with some but not all ports
- redirected.
-
-
- ΓòÉΓòÉΓòÉ 8.3. ArfQuery ArfQuery function ΓòÉΓòÉΓòÉ
-
- ArfQuery
-
- This function queries the redirection status of a serial port.
-
- ArfQuery(PortNumber, Status, DestString, LANANumber)
-
- Supplied Parameters
-
- PortNumber
- A word that specifies the serial port to be queried. The
- port number must be 1, 2, or 3.
-
- Returned Parameters
-
- Status
- Doubleword address of a byte variable. The redirection
- status of the specified serial port is returned to this
- byte variable. If Status=0, the serial port is not
- redirected. If Status=1, the serial port is redirected to
- a remote serial port. If Status=3, the serial port is
- redirected to another local serial port.
-
- DestString
- Doubleword address of a character buffer. A null
- terminated ASCII string will be returned in this buffer.
- If the serial port is redirected to a remote serial port,
- the string contains the NETBIOS name associated with the
- remote serial port. If the serial port is redirected to a
- local serial port, the string contains the device name of
- the local serial port (COM1, COM2, or COM3). If the serial
- port is not redirected, the string contains the device name
- of this serial port (COM1, COM2, or COM3). The maximum
- length of this string is 17 characters, including the
- terminating null byte.
-
- LANANumber
- Doubleword address of a word variable. If the serial port
- is redirected to a remote serial port, a value of 0 or 1 is
- returned in this word. This word specifies which LAN
- adapter is used on this OS/2 workstation when connecting to
- a remote serial port. If the serial port is not redirected
- to a remote serial port, 0 is returned in this word.
-
- Return Codes
-
- The following codes are valid for ArfQuery:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé Redirect directory does not exist Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 2 Γöé Invalid port number Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: If an unsuccessful return code is returned, the contents of
- the Status, DestString, and LANANumber variables are left
- unchanged.
-
-
- ΓòÉΓòÉΓòÉ 8.4. ArfRedirect ΓòÉΓòÉΓòÉ
-
- ArfRedirect
-
- This function redirects a serial port to a remote serial port or to
- another local serial port.
-
- ArfRedirect(PortNumber, DestString, LANANumber)
-
- Supplied Parameters
-
- PortNumber
- A word that specifies the serial port to be redirected. The
- port number must be 1, 2, or 3.
-
- DestString
- Doubleword address of a null terminated ASCII string. If
- the serial port is being redirected to a remote serial
- port, the string contains the NETBIOS name associated with
- the remote serial port. If the serial port is being
- redirected to another local serial port, the string
- contains the device name of a local serial port (COM1,
- COM2, or COM3). The maximum length of this string is 17
- characters, including the terminating null byte.
-
- LANANumber
- A word that specifies which LAN adapter to use on a
- specific OS/2 workstation when connecting to a remote
- serial port. This parameter is used only if the DestString
- is not COM1, COM2, or COM3. The LAN adapter number must be
- 0 or 1.
-
- Returned Parameters
-
- None.
-
- Return Codes
-
- The following codes are valid for ArfRedirect:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé Redirect directory does not exist Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 2 Γöé Invalid port number Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 3 Γöé Invalid LAN adapter number Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 4 Γöé Invalid destination string Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 5 Γöé Redirect directory in use Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 6 Γöé Port in use Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: Redirecting a serial port to itself cancels the redirection of
- that serial port. This can also be accomplished with the
- ArfUnRedirect function.
-
-
- ΓòÉΓòÉΓòÉ 8.5. ArfRestore ArfRestore function ΓòÉΓòÉΓòÉ
-
- ArfRestore
-
- This function restores the current redirection configuration to the
- permanent redirection configuration.
-
- ArfRestore()
-
- Supplied Parameters
-
- None.
-
- Returned Parameters
-
- None.
-
- Return Codes
-
- The following codes are valid for ArfRestore:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé Redirect directory does not exist Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 5 Γöé Redirect directory in use Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 6 Γöé Port in use Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé Communications Manager not started Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 8 Γöé File ACSARF.DAT not found Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 9 Γöé Error accessing file ACSARF.DAT Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: The contents of the redirection configuration data file,
- ACSARF.DAT, are copied to the redirect directory.
-
-
- ΓòÉΓòÉΓòÉ 8.6. ArfSave ArfSave function ΓòÉΓòÉΓòÉ
-
- ArfSave
-
- This function changes the current redirection configuration to the
- permanent redirection configuration.
-
- ArfSave()
-
- Supplied Parameters
-
- None.
-
- Returned Parameters
-
- None.
-
- Return Codes
-
- The following codes are valid for ArfSave:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé Redirect directory does not exist Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé Communications Manager not started Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 8 Γöé File ACSARF.DAT not found Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 9 Γöé Error accessing file ACSARF.DAT Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
- Note: The contents of the redirect directory are copied to the
- redirection configuration data file, ACSARF.DAT.
-
-
- ΓòÉΓòÉΓòÉ 8.7. ArfUnRedirect ΓòÉΓòÉΓòÉ
-
- ArfUnRedirect
-
- This function cancels the redirection of a serial port.
-
- ArfUnRedirect(PortNumber)
-
- Supplied Parameters
-
- PortNumber
- A word that specifies the redirected serial port to be
- canceled. The port number must be 1, 2, or 3.
-
- Returned Parameters
-
- None.
-
- Return Codes
-
- The following codes are valid for ArfUnRedirect:
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé RETURN Γöé Γöé
- Γöé CODE Γöé EXPLANATION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé Requested function successfully completed Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé Redirect directory does not exist Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 2 Γöé Invalid port number Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 5 Γöé Redirect directory in use Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 6 Γöé Port in use Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9. ACDI Return Codes ΓòÉΓòÉΓòÉ
-
- ACDI returns an indication of the success of the requested operation in the
- ReturnCode parameter. The only exception is when the verb control block address
- is not valid. When that occurs, ACDI sets the AX register as follows:
- AX = X'02'.
-
- ACDI Return Codes lists the hexadecimal codes, mnemonics, and descriptions of
- ACDI return codes.
-
-
- ΓòÉΓòÉΓòÉ 9.1. X'00' to X'09' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'00' Γöé "AA_SUCCESSFUL" Γöé The requested function was successful. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'01' Γöé "AA_INVALID_HANDLE" Γöé Invalid device handle. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'02' Γöé "AA_INVALID_PARM" Γöé Invalid parameter address. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'03' Γöé "AA_NO_CONNECTION" Γöé No connection exists. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé This return code specifies that the Γöé
- Γöé Γöé Γöé data communication link is not opera- Γöé
- Γöé Γöé Γöé tional at the time the verb is Γöé
- Γöé Γöé Γöé returned. This return code might be Γöé
- Γöé Γöé Γöé the result of any of the following Γöé
- Γöé Γöé Γöé situations: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o No connection existed when the Γöé
- Γöé Γöé Γöé verb was issued. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o Connection dropped before the Γöé
- Γöé Γöé Γöé operation on the verb was com- Γöé
- Γöé Γöé Γöé pleted. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A COMDISCONNECT verb was issued by Γöé
- Γöé Γöé Γöé the application before this verb Γöé
- Γöé Γöé Γöé was returned. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé This error is returned on a Γöé
- Γöé Γöé Γöé COMREADCHARSTRING or a COMREADBLOCK Γöé
- Γöé Γöé Γöé verb if a COMCONNECT verb is in Γöé
- Γöé Γöé Γöé progress and the CONNECTTYPE is not 2 Γöé
- Γöé Γöé Γöé (auto-dial). The application is Γöé
- Γöé Γöé Γöé allowed to retrieve call-progress mes- Γöé
- Γöé Γöé Γöé sages from the DCE during auto-dialing Γöé
- Γöé Γöé Γöé only. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'04' Γöé "AA_BIT_NOT_ZERO" Γöé Reserved bits not OFF. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'05' Γöé "AA_NO_V24_CMDS" Γöé No command string for V.24. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'06' Γöé "AA_CE_TIME_ZERO" Γöé Carrier exchange time-out must not be Γöé
- Γöé Γöé Γöé 0. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'07' Γöé "AA_NO_USER_CMDS" Γöé User-supplied command strings are not Γöé
- Γöé Γöé Γöé allowed. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé The network requirements for the spec- Γöé
- Γöé Γöé Γöé ified telephone network ID do not Γöé
- Γöé Γöé Γöé allow user-supplied command strings. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'08' Γöé "AA_INVALID_DEV_TYPE" Γöé Device type is not valid. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé The specified device type is not a Γöé
- Γöé Γöé Γöé valid value or the network require- Γöé
- Γöé Γöé Γöé ments for the specified telephone Γöé
- Γöé Γöé Γöé network ID do not allow this device to Γöé
- Γöé Γöé Γöé be specified. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'09' Γöé "AA_NO_COUNTRY_ENTRY" Γöé Could not find telephone network ID in Γöé
- Γöé Γöé Γöé telephony homologation file. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.2. X'0B' to X'0C' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'0B' Γöé "AA_INVALID_DEVICE" Γöé Invalid device name. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé If you redirected your port using ACDI Γöé
- Γöé Γöé Γöé Redirection, one of the following sit- Γöé
- Γöé Γöé Γöé uations may have occurred: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé non-redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé The device name specified is not Γöé
- Γöé Γöé Γöé COM1, COM2, or COM3. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé If the device name is correct Γöé
- Γöé Γöé Γöé (COM1, COM2, or COM3) and the Γöé
- Γöé Γöé Γöé device is redirected, this return Γöé
- Γöé Γöé Γöé code indicates that ACDI was not Γöé
- Γöé Γöé Γöé able to add the ACDI Redirection Γöé
- Γöé Γöé Γöé local NETBIOS name to the LAN. Γöé
- Γöé Γöé Γöé The ACDI Redirection local NETBIOS Γöé
- Γöé Γöé Γöé name is specified in the Γöé
- Γöé Γöé Γöé CONFIG.SYS file at the end of the Γöé
- Γöé Γöé Γöé DEVICE=C:\CMLIB\ASYNCDDE.SYS Γöé
- Γöé Γöé Γöé statement. The most likely cause Γöé
- Γöé Γöé Γöé of this error is that the ACDI Γöé
- Γöé Γöé Γöé Redirection local NETBIOS name Γöé
- Γöé Γöé Γöé already exists on the LAN. Ensure Γöé
- Γöé Γöé Γöé that the ACDI Redirection local Γöé
- Γöé Γöé Γöé NETBIOS name is not being used by Γöé
- Γöé Γöé Γöé another workstation on the LAN, Γöé
- Γöé Γöé Γöé and ensure that the ACDI Redi- Γöé
- Γöé Γöé Γöé rection local NETBIOS name is not Γöé
- Γöé Γöé Γöé being used by another LAN applica- Γöé
- Γöé Γöé Γöé tion on this workstation. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'0C' Γöé "AA_DOSOPEN_ERROR" Γöé Device cannot be opened. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé If you redirected your port using ACDI Γöé
- Γöé Γöé Γöé Redirection, one of the following sit- Γöé
- Γöé Γöé Γöé uations may have occurred: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé non-redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI was not able to open the Γöé
- Γöé Γöé Γöé standard ACDI device driver Γöé
- Γöé Γöé Γöé (ASYNCDDA.SYS or ASYNCDDB.SYS). Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI was not able to open the ACDI Γöé
- Γöé Γöé Γöé Redirection device driver Γöé
- Γöé Γöé Γöé (ASYNCDDE.SYS). This error can be Γöé
- Γöé Γöé Γöé caused by NETBIOS not being loaded Γöé
- Γöé Γöé Γöé on the workstation. This error Γöé
- Γöé Γöé Γöé also can be caused if ACDI is Γöé
- Γöé Γöé Γöé redirected to a NETBIOS name that Γöé
- Γöé Γöé Γöé does not exist on the LAN. Ensure Γöé
- Γöé Γöé Γöé that the NETBIOS name, to which Γöé
- Γöé Γöé Γöé ACDI has been redirected, is the Γöé
- Γöé Γöé Γöé correct name and that it is Γöé
- Γöé Γöé Γöé entered correctly on the REDIRECT Γöé
- Γöé Γöé Γöé command. You may also want to Γöé
- Γöé Γöé Γöé ensure that the LANACS, to which Γöé
- Γöé Γöé Γöé the NETBIOS name belongs, is Γöé
- Γöé Γöé Γöé running. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.3. X'0D' to X'35' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'0D' Γöé "AA_INCOMPAT_DEVICE" Γöé The device driver installed is not Γöé
- Γöé Γöé Γöé compatible with the hardware on this Γöé
- Γöé Γöé Γöé machine. Ensure ASYNCDDA.SYS is Γöé
- Γöé Γöé Γöé installed if you are using an IBM PC Γöé
- Γöé Γöé Γöé AT or equivalent or ASYNCDDB.SYS is Γöé
- Γöé Γöé Γöé installed if you are using an IBM Γöé
- Γöé Γöé Γöé PS/2. If you are using an IBM PS/2 or Γöé
- Γöé Γöé Γöé equivalent that has hardware to Γöé
- Γöé Γöé Γöé support Direct Memory Access (DMA) Γöé
- Γöé Γöé Γöé Asynchronous Communications, you may Γöé
- Γöé Γöé Γöé use either ASYNCDDB.SYS or Γöé
- Γöé Γöé Γöé ASYNCDDC.SYS. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'0E' Γöé "AA_NO_HOMOL_FILE" Γöé Could not find the telephony Γöé
- Γöé Γöé Γöé homologation file. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'0F' Γöé "AA_NO_REQUIRED_FILE" Γöé Could not find a required ACDI config- Γöé
- Γöé Γöé Γöé uration file. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'10' Γöé "AA_CFI_FLAG_CONFLICT" Γöé The call failure response flags con- Γöé
- Γöé Γöé Γöé flict for one or more call failure Γöé
- Γöé Γöé Γöé response strings. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For example, at least 2 bits are ON Γöé
- Γöé Γöé Γöé for a single string or no bits are ON Γöé
- Γöé Γöé Γöé for a string that has a length greater Γöé
- Γöé Γöé Γöé than 0. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'11' Γöé "AA_OTHER_REQ" Γöé Cannot close device. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé There are requests in progress and a Γöé
- Γöé Γöé Γöé connection may still exist for this Γöé
- Γöé Γöé Γöé device. Terminate the outstanding Γöé
- Γöé Γöé Γöé requests and disconnect, if necessary. Γöé
- Γöé Γöé Γöé Then reissue the COMCLOSE verb. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'14' Γöé "AA_BPS_INVALID" Γöé One or both of the specified line Γöé
- Γöé Γöé Γöé speeds (bps) are not supported. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'17' Γöé "AA_BPS_UNDEFINED" Γöé One or both of the specified line Γöé
- Γöé Γöé Γöé speeds (bps) are not defined. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'2A' Γöé "AA_BPS_DIFFER" Γöé Transmit and receive bps rates must be Γöé
- Γöé Γöé Γöé the same for this device. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'2D' Γöé "AA_STOP_BIT_INVALID" Γöé Invalid (or unsupported) number of Γöé
- Γöé Γöé Γöé stop bits has been specified. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'2F' Γöé "AA_PARITY_INVALID" Γöé Invalid (or unsupported) parity has Γöé
- Γöé Γöé Γöé been specified. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'31' Γöé "AA_BIT_INVALID" Γöé Invalid (or unsupported) number of Γöé
- Γöé Γöé Γöé data bits has been specified. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'32' Γöé "AA_LINE_CTRL_INCOMPAT" Γöé Incompatible line control settings. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For example, setting 2 stop bits with Γöé
- Γöé Γöé Γöé 5 data bits. See ComSetLineCtrl Γöé
- Γöé Γöé Γöé (X'05') for valid combinations. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'33' Γöé "AA_UNBLOCKTHREAD_ISSUED" Γöé Verb was unblocked prematurely because Γöé
- Γöé Γöé Γöé a COMUNBLOCKTHREAD verb was received. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'34' Γöé "AA_INVALID_FUNC_CODE" Γöé Function code of the verb is invalid. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'35' Γöé "AA_AUTO_FLOW_ACTIVE" Γöé Automatic flow control in progress. Γöé
- Γöé Γöé Γöé 0row. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.4. X'36' to X'3B' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'36' Γöé "AA_DEV_OPEN_EXHAUSTED" Γöé Device already opened by this process Γöé
- Γöé Γöé Γöé or by other processes. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé NOTE: If the device has already been Γöé
- Γöé Γöé Γöé opened by other processes, this Γöé
- Γöé Γöé Γöé return code is returned if the Γöé
- Γöé Γöé Γöé port cannot be shared, if it Γöé
- Γöé Γöé Γöé has been opened by the maximum Γöé
- Γöé Γöé Γöé number of allowed processes, or Γöé
- Γöé Γöé Γöé if it is owned by another Γöé
- Γöé Γöé Γöé device driver at this time. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé If you redirected your port using ACDI Γöé
- Γöé Γöé Γöé Redirection, one of the following sit- Γöé
- Γöé Γöé Γöé uations may have occurred: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé non-redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI is not able to open the Γöé
- Γöé Γöé Γöé serial port because the port is Γöé
- Γöé Γöé Γöé temporarily being used by another Γöé
- Γöé Γöé Γöé device driver (such as COM01.SYS Γöé
- Γöé Γöé Γöé or COM02.SYS). Try again later. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by COMOPEN verb of a Γöé
- Γöé Γöé Γöé redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI is not able to open a remote Γöé
- Γöé Γöé Γöé serial port because the remote Γöé
- Γöé Γöé Γöé serial port is temporarily being Γöé
- Γöé Γöé Γöé used by another workstation. Try Γöé
- Γöé Γöé Γöé again later. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'37' Γöé "AA_OUT_CANCELLED" Γöé Processing cancelled by the Γöé
- Γöé Γöé Γöé COMFLUSHOUTPUT verb. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'38' Γöé "AA_WRITE_OUTSTANDING" Γöé An outstanding COMWRITECHARSTRING verb Γöé
- Γöé Γöé Γöé exists for this process and handle. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé This error is returned on the Γöé
- Γöé Γöé Γöé COMDEFOUTPUTBUFF verb to allow the Γöé
- Γöé Γöé Γöé application to flush or drain the Γöé
- Γöé Γöé Γöé output buffer, redefine the buffer, Γöé
- Γöé Γöé Γöé and reissue the write request. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé This error is also returned on the Γöé
- Γöé Γöé Γöé COMDRAINOUTPUT verb. The drain and Γöé
- Γöé Γöé Γöé the write functions are opposing func- Γöé
- Γöé Γöé Γöé tions. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'39' Γöé "AA_XON_GE_XOFF" Γöé The specified XOFF buffer level is Γöé
- Γöé Γöé Γöé greater than or equal to the XON Γöé
- Γöé Γöé Γöé buffer level. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3A' Γöé "AA_INPUT_CANCELLED" Γöé Verb cancelled by a COMFLUSHINPUT Γöé
- Γöé Γöé Γöé verb. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3B' Γöé "AA_IO_BUFF_UNDEFINED" Γöé The input buffer or the output buffer Γöé
- Γöé Γöé Γöé has not been defined. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.5. X'3C' to X'4E' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3C' Γöé "AA_IO_CMD_OUTSTANDING" Γöé A previous I/O request is still in Γöé
- Γöé Γöé Γöé progress. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé One of the following conditions is Γöé
- Γöé Γöé Γöé present: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A previous COMWRITECHARSTRING verb Γöé
- Γöé Γöé Γöé is still in progress if returned Γöé
- Γöé Γöé Γöé on a COMWRITECHARSTRING verb. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A previous COMTRANSIMM verb is Γöé
- Γöé Γöé Γöé still in progress if returned on a Γöé
- Γöé Γöé Γöé COMTRANSIMM verb. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A previous COMREADCHARSTRING verb Γöé
- Γöé Γöé Γöé is still in progress if returned Γöé
- Γöé Γöé Γöé on a COMREADCHARSTRING verb. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A previous COMREADBLOCK verb is Γöé
- Γöé Γöé Γöé still in progress if returned on a Γöé
- Γöé Γöé Γöé COMREADBLOCK verb. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3D' Γöé "AA_BUFF_LEVEL_INVALID" Γöé Buffer level is invalid. A buffer Γöé
- Γöé Γöé Γöé level is invalid if it is 0 or larger Γöé
- Γöé Γöé Γöé than the usable size of the applica- Γöé
- Γöé Γöé Γöé tion input data buffer. See Γöé
- Γöé Γöé Γöé ComDefInput (X'14') for more informa- Γöé
- Γöé Γöé Γöé tion on the usable size of the buffer. Γöé
- Γöé Γöé Γöé This error can be caused by setting Γöé
- Γöé Γöé Γöé the XON buffer to a greater value than Γöé
- Γöé Γöé Γöé the application input buffer. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3E' Γöé "AA_EXCESS_BLOCKS" Γöé More than 128 blocks possible in Γöé
- Γöé Γöé Γöé buffer. This is a warning that is Γöé
- Γöé Γöé Γöé returned for a fixed-length block Γöé
- Γöé Γöé Γöé input mode. It is just a warning and Γöé
- Γöé Γöé Γöé the new input buffer and mode have Γöé
- Γöé Γöé Γöé been defined and are active. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'3F' Γöé "AA_READ_OUTSTANDING" Γöé A COMREADCHARSTRING or COMREADBLOCK Γöé
- Γöé Γöé Γöé verb is outstanding for this process. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'40' Γöé "AA_DURATION_INVALID" Γöé Specified duration is invalid. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'44' Γöé "AA_SEMAPHORE_INVALID" Γöé Invalid semaphore handle. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'45' Γöé "AA_LOCK_FAILURE" Γöé Data segment cannot be locked. The Γöé
- Γöé Γöé Γöé previously defined input buffer has Γöé
- Γöé Γöé Γöé been unlocked if returned on a Γöé
- Γöé Γöé Γöé COMDEFINPUT verb, or the previously Γöé
- Γöé Γöé Γöé defined output buffer has been Γöé
- Γöé Γöé Γöé unlocked if returned on a Γöé
- Γöé Γöé Γöé COMDEFOUTPUTBUFF verb. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé NOTE: When this return code is Γöé
- Γöé Γöé Γöé returned, ACDI assumes it has Γöé
- Γöé Γöé Γöé no buffer defined (either input Γöé
- Γöé Γöé Γöé or output, depending on which Γöé
- Γöé Γöé Γöé verb returned the error). Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'49' Γöé "AA_MODE_REQ_INVALID" Γöé The requested mode is invalid. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'4B' Γöé "AA_EOB_INVALID" Γöé Invalid string length or number of Γöé
- Γöé Γöé Γöé strings. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'4E' Γöé "AA_BUFF_NOT_EMPTY" Γöé Output buffer is not empty yet. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.6. X'51' to X'54' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'51' Γöé "AA_BUFF_OVERRUN" Γöé BYTESWRITTEN is larger than the avail- Γöé
- Γöé Γöé Γöé able space in the application output Γöé
- Γöé Γöé Γöé buffer. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé This is considered a critical error. Γöé
- Γöé Γöé Γöé Before returning this error, ACDI sets Γöé
- Γöé Γöé Γöé NEXTAVAILWRITEPTR to the beginning of Γöé
- Γöé Γöé Γöé the output buffer and Γöé
- Γöé Γöé Γöé NEXTAVAILWRITELGTH to the output Γöé
- Γöé Γöé Γöé buffer size. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé Asynchronous I/O buffers should be Γöé
- Γöé Γöé Γöé defined such that the maximum number Γöé
- Γöé Γöé Γöé of characters (that a single view of Γöé
- Γöé Γöé Γöé the buffer would indicate) is one less Γöé
- Γöé Γöé Γöé than the total size of the buffer; for Γöé
- Γöé Γöé Γöé example, the maximum amount of data Γöé
- Γöé Γöé Γöé that can be in the buffer at any one Γöé
- Γöé Γöé Γöé time is the buffer size minus 1 byte. Γöé
- Γöé Γöé Γöé The output buffer size should be at Γöé
- Γöé Γöé Γöé least 1 byte larger than the maximum Γöé
- Γöé Γöé Γöé number of bytes written by a single Γöé
- Γöé Γöé Γöé COMWRITECHARSTRING verb. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'52' Γöé "AA_BYTE_NEED_OVERRUN" Γöé The parameter for bytes needed is Γöé
- Γöé Γöé Γöé larger than the usable space of the Γöé
- Γöé Γöé Γöé process buffer. ACDI returns without Γöé
- Γöé Γöé Γöé performing any read or write function. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé Asynchronous I/O buffers should be Γöé
- Γöé Γöé Γöé defined such that the maximum number Γöé
- Γöé Γöé Γöé of characters (that a single view of Γöé
- Γöé Γöé Γöé the buffer would indicate) is one byte Γöé
- Γöé Γöé Γöé less than the total size of the Γöé
- Γöé Γöé Γöé buffer. For example, the maximum Γöé
- Γöé Γöé Γöé amount of data that could be in the Γöé
- Γöé Γöé Γöé buffer at any one time is the buffer Γöé
- Γöé Γöé Γöé size minus 1 byte. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'53' Γöé "AA_TIMEOUT_XOFF" Γöé Time-out exceeded while in XOFF state. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For the COMREADCHARSTRING and Γöé
- Γöé Γöé Γöé COMREADBLOCK verbs, ACDI has put the Γöé
- Γöé Γöé Γöé characters received (if any) prior to Γöé
- Γöé Γöé Γöé the time-out in the input buffer and Γöé
- Γöé Γöé Γöé adjusted the returned buffer parame- Γöé
- Γöé Γöé Γöé ters (NEXTAVAILREADPTR and Γöé
- Γöé Γöé Γöé NEXTAVAILREADLGTH), accordingly. This Γöé
- Γöé Γöé Γöé is returned if an XOFF has been sent. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For the COMWRITECHARSTRING verb, ACDI Γöé
- Γöé Γöé Γöé has adjusted the returned parameters Γöé
- Γöé Γöé Γöé (NEXTAVAILWRITEPTR and Γöé
- Γöé Γöé Γöé NEXTAVAILWRITELGTH) to correctly Γöé
- Γöé Γöé Γöé reflect the actual free bytes avail- Γöé
- Γöé Γöé Γöé able in the output buffer. This is Γöé
- Γöé Γöé Γöé returned if the application has issued Γöé
- Γöé Γöé Γöé a COMSTOPTRANS or received an XOFF. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'54' Γöé "AA_TIMEOUT_XON" Γöé Time-out occurred while not in XOFF Γöé
- Γöé Γöé Γöé state. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For the COMREADCHARSTRING and Γöé
- Γöé Γöé Γöé COMREADBLOCK verbs, ACDI has put the Γöé
- Γöé Γöé Γöé characters received (if any) prior to Γöé
- Γöé Γöé Γöé the time-out in the input buffer and Γöé
- Γöé Γöé Γöé adjusted the returned buffer parame- Γöé
- Γöé Γöé Γöé ters (NEXTAVAILREADPTR and Γöé
- Γöé Γöé Γöé NEXTAVAILREADLGTH) accordingly. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé For the COMWRITECHARSTRING verb, ACDI Γöé
- Γöé Γöé Γöé has adjusted the returned parameters Γöé
- Γöé Γöé Γöé (NEXTAVAILWRITEPTR and Γöé
- Γöé Γöé Γöé NEXTAVAILWRITELGTH) to correctly Γöé
- Γöé Γöé Γöé reflect the actual bytes available in Γöé
- Γöé Γöé Γöé the output buffer. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.7. X'55' to X'61' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'55' Γöé "AA_DATA_ERR" Γöé The data contains an error (parity or Γöé
- Γöé Γöé Γöé framing) or is incomplete (overflow or Γöé
- Γöé Γöé Γöé overrun). The thread of execution is Γöé
- Γöé Γöé Γöé returned to prevent an infinite wait Γöé
- Γöé Γöé Γöé in case the end of the block string Γöé
- Γöé Γöé Γöé was corrupted or lost by the errors in Γöé
- Γöé Γöé Γöé the data. The data has been placed Γöé
- Γöé Γöé Γöé into the input buffer, and the Γöé
- Γöé Γöé Γöé pointers have been adjusted accord- Γöé
- Γöé Γöé Γöé ingly. The READERRORMASK parameter is Γöé
- Γöé Γöé Γöé updated to reflect the error. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé NOTE: This return code is returned Γöé
- Γöé Γöé Γöé only in variable-length block Γöé
- Γöé Γöé Γöé mode. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'57' Γöé "AA_BLOCK_MODE" Γöé This verb is not valid in the current Γöé
- Γöé Γöé Γöé input mode. For example, COMREADBLOCK Γöé
- Γöé Γöé Γöé is not valid in character input mode. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'59' Γöé "AA_BYTES_FREE_OVERRUN" Γöé BYTEFREED is larger than the number of Γöé
- Γöé Γöé Γöé available characters returned in Γöé
- Γöé Γöé Γöé NEXTAVAILREADLGTH on the previous Γöé
- Γöé Γöé Γöé COMREADCHARSTRING verb. This is con- Γöé
- Γöé Γöé Γöé sidered a critical error. Γöé
- Γöé Γöé Γöé NEXTAVAILREADLGTH is set to 0, and Γöé
- Γöé Γöé Γöé NEXTAVAILREADPTR is set to the start Γöé
- Γöé Γöé Γöé of the input buffer. Subsequent input Γöé
- Γöé Γöé Γöé data begins from that point. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'5C' Γöé "AA_BLOCK_SIZE_INVALID" Γöé Invalid block or buffer size. You Γöé
- Γöé Γöé Γöé have attempted to define a block (in Γöé
- Γöé Γöé Γöé fixed-length block mode) or a buffer Γöé
- Γöé Γöé Γöé (either input or output) that is not Γöé
- Γöé Γöé Γöé valid. See the description of the Γöé
- Γöé Γöé Γöé appropriate verb for valid sizes. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'5D' Γöé "AA_BUFF_SIZE_INVALID" Γöé The input buffer is smaller than the Γöé
- Γöé Γöé Γöé block size. This error is only issued Γöé
- Γöé Γöé Γöé when the input mode is fixed-length Γöé
- Γöé Γöé Γöé block. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé Asynchronous I/O buffers should be Γöé
- Γöé Γöé Γöé defined such that the maximum number Γöé
- Γöé Γöé Γöé of characters (that a single view of Γöé
- Γöé Γöé Γöé the buffer would indicate) is one less Γöé
- Γöé Γöé Γöé than the total size of the buffer; for Γöé
- Γöé Γöé Γöé example, the maximum amount of data Γöé
- Γöé Γöé Γöé that can be in the buffer at any one Γöé
- Γöé Γöé Γöé time is the buffer size minus 1 byte. Γöé
- Γöé Γöé Γöé The input buffer size should be at Γöé
- Γöé Γöé Γöé least 1 byte larger than the fixed- Γöé
- Γöé Γöé Γöé length block size. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'5E' Γöé "AA_REC_SIZE_OVERRUN" Γöé The input buffer is full, but the Γöé
- Γöé Γöé Γöé specified end-of-block strings have Γöé
- Γöé Γöé Γöé not been received yet. Γöé
- Γöé Γöé Γöé NEXTAVAILBLKPTR is set to the start of Γöé
- Γöé Γöé Γöé data and NEXTAVAILREADLGTH is set to Γöé
- Γöé Γöé Γöé the input buffer size. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé The application should process the Γöé
- Γöé Γöé Γöé input buffer and issue the Γöé
- Γöé Γöé Γöé COMREADBLOCK verb again if an end-of- Γöé
- Γöé Γöé Γöé block string is not found (the block Γöé
- Γöé Γöé Γöé may be very large and the end may not Γöé
- Γöé Γöé Γöé have been received yet). Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'61' Γöé "AA_NO_DCE_RESPONSE" Γöé The DCE hardware is not responding. Γöé
- Γöé Γöé Γöé The CTS signal was not asserted within Γöé
- Γöé Γöé Γöé 10 seconds of ACDI asserting RTS. No Γöé
- Γöé Γöé Γöé connection was made. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.8. X'62' to X'7B' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'62' Γöé "AA_TIMEOUT_INVALID" Γöé Invalid time-out. The requested Γöé
- Γöé Γöé Γöé INITIALWAIT time is invalid if Γöé
- Γöé Γöé Γöé returned on a COMREADCHARSTRING verb. Γöé
- Γöé Γöé Γöé Any of the time-outs specified on the Γöé
- Γöé Γöé Γöé COMSETTIMEOUT verb are also invalid. Γöé
- Γöé Γöé Γöé The requested READTIMEOUTCHAR time is Γöé
- Γöé Γöé Γöé invalid if returned on a Γöé
- Γöé Γöé Γöé COMREADCHARSTRING verb or the Γöé
- Γöé Γöé Γöé requested CONNECTTIMEOUT time is Γöé
- Γöé Γöé Γöé invalid if returned on a COMCONNECT Γöé
- Γöé Γöé Γöé verb. See the appropriate parameter Γöé
- Γöé Γöé Γöé description for valid values. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'63' Γöé "AA_NEGATED_DSR_VIOLATION" Γöé The DSR signal was not negated for at Γöé
- Γöé Γöé Γöé least 100 milliseconds prior to Γöé
- Γöé Γöé Γöé attempting a call connection with the Γöé
- Γöé Γöé Γöé attached V.25bis or V.24 DCE. No con- Γöé
- Γöé Γöé Γöé nection was made. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'65' Γöé "AA_CALL_VIOLATION" Γöé Call attempt violates regulations of Γöé
- Γöé Γöé Γöé the attached network. No call is Γöé
- Γöé Γöé Γöé made. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'66' Γöé "AA_CALL_COUNT_EXCEEDED" Γöé Call attempt cannot be made because Γöé
- Γöé Γöé Γöé system resources are exhausted. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'67' Γöé "AA_TIMEOUT" Γöé Time-out occurred on a COMCONNECT Γöé
- Γöé Γöé Γöé verb. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé The call is attempted by ACDI. If the Γöé
- Γöé Γöé Γöé attempt is unsuccessful, call attempt Γöé
- Γöé Γöé Γöé failed (X'67') is returned. The pos- Γöé
- Γöé Γöé Γöé sible reasons for failure are: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o The DCE rejected one or more of Γöé
- Γöé Γöé Γöé the commands in the command Γöé
- Γöé Γöé Γöé string. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o A call collision occurred. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o No call failure indication or con- Γöé
- Γöé Γöé Γöé nection indication was detected Γöé
- Γöé Γöé Γöé prior to the expiration of the Γöé
- Γöé Γöé Γöé time-out timer. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'69' Γöé "AA_PORT_IN_USE" Γöé The physical port is being used for a Γöé
- Γöé Γöé Γöé connection at this time. The applica- Γöé
- Γöé Γöé Γöé tion must either wait to issue the Γöé
- Γöé Γöé Γöé verb later or use another device. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'6C' Γöé "AA_NETWORK_REQ_ERROR" Γöé The requested connection time-out Γöé
- Γöé Γöé Γöé value violates the network require- Γöé
- Γöé Γöé Γöé ments. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'6D' Γöé "AA_CONNECT_SWITCHED" Γöé Successful switched connection. This Γöé
- Γöé Γöé Γöé return code returns only when Γöé
- Γöé Γöé Γöé CONNECTTYPE=4. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'6E' Γöé "AA_CONNECT_NONSWITCHED" Γöé Successful non-switched connection. Γöé
- Γöé Γöé Γöé This return code returns only when Γöé
- Γöé Γöé Γöé CONNECTTYPE=4. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'71' Γöé "AA_FUNC_INVALID_FOR_DEVICE"Γöé The connect type is not supported for Γöé
- Γöé Γöé Γöé this device. This error is returned Γöé
- Γöé Γöé Γöé when a requested function cannot be Γöé
- Γöé Γöé Γöé accommodated by the target device. Γöé
- Γöé Γöé Γöé For example, some devices do not Γöé
- Γöé Γöé Γöé support auto-dialing or auto- Γöé
- Γöé Γöé Γöé answering. Another example would be a Γöé
- Γöé Γöé Γöé manual call request for non-switched Γöé
- Γöé Γöé Γöé data connection such as issuing a con- Γöé
- Γöé Γöé Γöé nection with CONNECTTYPE=1. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'7B' Γöé "AA_CALL_COLLISION" Γöé Call collision occurred. A call col- Γöé
- Γöé Γöé Γöé lision occurs only when an incoming Γöé
- Γöé Γöé Γöé call is detected while an outgoing Γöé
- Γöé Γöé Γöé call (either manual dialing or auto- Γöé
- Γöé Γöé Γöé dialing) is being tried. No con- Γöé
- Γöé Γöé Γöé nection is made. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 9.9. X'80' to X'FF' ΓòÉΓòÉΓòÉ
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé ACDI Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé HEX Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γöé CODE Γöé Γöé Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'80' Γöé "AA_DEST_NO_HANGUP" Γöé Time-out occurred on disconnect. The Γöé
- Γöé Γöé Γöé line was not freed after on-hook Γöé
- Γöé Γöé Γöé placement. The user should manually Γöé
- Γöé Γöé Γöé verify on-hook condition. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'F0' Γöé "AA_RESERVED_BYTE" Γöé The reserved byte is not 0. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'F1' Γöé "AA_OS2_ERROR" Γöé An OS/2 error occurred during exe- Γöé
- Γöé Γöé Γöé cution. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé If you redirected your port using ACDI Γöé
- Γöé Γöé Γöé Redirection, one of the following sit- Γöé
- Γöé Γöé Γöé uations may have occurred: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by an ACDI verb of a Γöé
- Γöé Γöé Γöé non-redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI received an error return code Γöé
- Γöé Γöé Γöé from an operating system call. Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé o If returned by an ACDI verb of a Γöé
- Γöé Γöé Γöé redirected port: Γöé
- Γöé Γöé Γöé Γöé
- Γöé Γöé Γöé ACDI received an error return code Γöé
- Γöé Γöé Γöé from an operating system call, or Γöé
- Γöé Γöé Γöé the NETBIOS session to the remote Γöé
- Γöé Γöé Γöé serial port has been lost. This Γöé
- Γöé Γöé Γöé error may occur if the LAN commu- Γöé
- Γöé Γöé Γöé nication ends or if the LANACS Γöé
- Γöé Γöé Γöé communication ends while ACDI is Γöé
- Γöé Γöé Γöé using a redirected port. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'F4' Γöé "AA_BAD_VERSION" Γöé Invalid version of ACDI. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé X'FF' Γöé "AA_STOPPED_OR_NOT_STARTED" Γöé ACDI has been started or stopped. If Γöé
- Γöé Γöé Γöé ACDI has been stopped by an abnormal Γöé
- Γöé Γöé Γöé stop, then your application must end Γöé
- Γöé Γöé Γöé before ACDI can be restarted. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-
-
- ΓòÉΓòÉΓòÉ 10. ACDI Redirection API Return Codes ΓòÉΓòÉΓòÉ
-
- ACDI Redirection displays an indication of the success of the requested
- operation in the ReturnCode parameter.
-
- API Return Codes lists the ACDI Redirection return codes and mnemonics.
-
- -ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ+
- Γöé API Return Codes Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé RETURN Γöé Γöé Γöé
- Γöé CODE Γöé MNEMONIC Γöé DESCRIPTION Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 0 Γöé "AR_SUCCESSFUL" Γöé Requested function successfully Γöé
- Γöé Γöé Γöé completed. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 1 Γöé "AR_ACDI_NOT_STARTED" Γöé Redirect directory does not Γöé
- Γöé Γöé Γöé exist. Either ACDI has not Γöé
- Γöé Γöé Γöé been started, or the redi- Γöé
- Γöé Γöé Γöé rection configuration data Γöé
- Γöé Γöé Γöé file, ACSARF.DAT, is missing Γöé
- Γöé Γöé Γöé from the \CMLIB directory. The Γöé
- Γöé Γöé Γöé redirect directory is a shared Γöé
- Γöé Γöé Γöé memory segment owned by ACDI. Γöé
- Γöé Γöé Γöé When ACDI starts, it creates Γöé
- Γöé Γöé Γöé the redirect directory and Γöé
- Γöé Γöé Γöé copies the contents of the Γöé
- Γöé Γöé Γöé redirection configuration data Γöé
- Γöé Γöé Γöé file, ACSARF.DAT, into the Γöé
- Γöé Γöé Γöé redirect directory. If the Γöé
- Γöé Γöé Γöé redirection configuration file Γöé
- Γöé Γöé Γöé is missing, ACDI does not Γöé
- Γöé Γöé Γöé create the redirect directory. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 2 Γöé "AR_INVALID_PORT_NUM" Γöé Invalid port number. The spec- Γöé
- Γöé Γöé Γöé ified port number is not 1, 2, Γöé
- Γöé Γöé Γöé or 3. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 3 Γöé "AR_INVALID_LAN_NUM" Γöé Invalid LAN adapter number. Γöé
- Γöé Γöé Γöé The specified LAN adapter Γöé
- Γöé Γöé Γöé number is not 0 or 1. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 4 Γöé "AR_INVALID_DEST_STR" Γöé Invalid destination string. Γöé
- Γöé Γöé Γöé The specified destination Γöé
- Γöé Γöé Γöé string is longer than 17 char- Γöé
- Γöé Γöé Γöé acters. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 5 Γöé "AR_DIRECTORY_IN_USE" Γöé Redirect directory in use. Γöé
- Γöé Γöé Γöé ACDI or another application is Γöé
- Γöé Γöé Γöé currently modifying the redi- Γöé
- Γöé Γöé Γöé rect directory. Only one Γöé
- Γöé Γöé Γöé application is allowed to Γöé
- Γöé Γöé Γöé modify the redirect directory Γöé
- Γöé Γöé Γöé at a time. Try again later. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 6 Γöé "AR_PORT_IN_USE" Γöé Port in use. The specified Γöé
- Γöé Γöé Γöé serial port is currently in Γöé
- Γöé Γöé Γöé use. The redirection config- Γöé
- Γöé Γöé Γöé uration of a serial port cannot Γöé
- Γöé Γöé Γöé be changed while the serial Γöé
- Γöé Γöé Γöé port is being used. Wait until Γöé
- Γöé Γöé Γöé the serial port is closed and Γöé
- Γöé Γöé Γöé then change its redirection Γöé
- Γöé Γöé Γöé configuration. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 7 Γöé "AR_CM_NOT_STARTED" Γöé Communications Manager not Γöé
- Γöé Γöé Γöé started. Unless Communications Γöé
- Γöé Γöé Γöé Manager is started, the ACDI Γöé
- Γöé Γöé Γöé Redirection API cannot deter- Γöé
- Γöé Γöé Γöé mine on which volume and direc- Γöé
- Γöé Γöé Γöé tory to save, restore, or Γöé
- Γöé Γöé Γöé create the redirection config- Γöé
- Γöé Γöé Γöé uration data file, ACSARF.DAT. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 8 Γöé "AR_DATA_FILE_NOT_FOUND" Γöé File ACSARF.DAT not found. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 9 Γöé "AR_BAD_DATA_FILE" Γöé Error accessing file Γöé
- Γöé Γöé Γöé ACSARF.DAT. Γöé
- Γö£ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö╝ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöñ
- Γöé 10 Γöé "AR_DATA_FILE_ALREADY_EXISTS" Γöé File ACSARF.DAT already exists. Γöé
- ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
-