home *** CD-ROM | disk | FTP | other *** search
/ The Best of Mecomp Multimedia 2 / MECOMP-CD-II.iso / amiga / tools / system / scsi_44-38 / scsidocs / unitcontrol.notes < prev   
Encoding:
Text File  |  1998-01-26  |  2.1 KB  |  88 lines

  1. UnitControl 2.17
  2. - Prefs have no meaning for a V44(V9) device as it`s using
  3.   the new BootMenu now.
  4. - blizzppc.device added
  5.  
  6. UnitControl 2.16
  7. - Shows a Widetermination problem now...>=44.30 needed from
  8.   the cybppc.device
  9.  
  10. UnitControl 2.15
  11. - Sorry..reselection was disabled on non PPC controllers and
  12.   Wide was active on non PPC controller...wrong taglist entry.
  13.  
  14. UnitControl 2.14
  15. - Better Wide/Scroller interaction
  16.  
  17. UnitControl 2.13
  18. - Fixed a devide by 0 exception in the synchronize calculation.
  19.  
  20. UnitControl 2.12
  21. - Added WIDE cli parameter
  22. - Fixed some error check
  23.  
  24. UnitControl 2.11
  25. - Widedevice now has 16 units in the prefs window
  26. - Fixed Rescan(CLI) enforcer hit
  27. - Cleaned up some non wide unit id usage in the cli output stage
  28. - Relayouted the cli output
  29.  
  30. UnitControl 2.10
  31. - Fixed synchron > 10MB limitation in commandline mode
  32. - Changed the MB gauge to show the real transfer bandwidth, instead of
  33.   the synchron clock speed. So now it also cares for wide mode.
  34.  
  35. UnitControl 2.9
  36. - Fixed synchron > 10MB limitation
  37.  
  38. UnitControl 2.8
  39. - Added new UnitID support
  40. - Added Wide support
  41. - Added Ultra support
  42. - minor changes
  43.  
  44. UnitControl 2.7
  45. - Copyright Text changes
  46.  
  47. UnitControl 2.6
  48. - Added Motor Off for SCSIDirect Calls
  49. - Rescan should ignore Luns for Scanners from now on
  50.   like the Device Boot Scan....MUSTEK Cludge
  51.  
  52. UnitControl 2.5
  53. - Support fuer LunReselection Switch in prefs
  54.  
  55. UnitControl 2.4
  56. - Fixed Rescan Crash with device= startup
  57.  
  58. UnitControl 2.3
  59. - Improved Verbose output...now it shows more unit settings
  60.  
  61. UnitControl 2.2
  62. - Minor changes
  63.  
  64. UnitControl 2.1
  65. - Fixed Window size problem
  66.  
  67. UnitControl 2.0
  68. - Changed "Special" to "Options"
  69. - Removed SCSIDirektPolling command and gadget because V7 doesn't support this
  70.   anymore
  71. - Added new Prefs Window for device options
  72. - Added new CLI commands for Prefs settings
  73. - Added new output to "Verbose"
  74. - Added Rescan command and gadget to include units that couldn't be detected
  75.   on device startup
  76.  
  77. UnitControl 1.7
  78. - Phase5 name change
  79. - Lun activated for new MultiLun scsi device
  80.  
  81. UnitControl 1.6
  82. - Some bug fixes
  83.  
  84. UnitControl 1.5
  85.  
  86. - Fixed a wrong status result
  87. - Improved Error Output of the cli interface
  88. - fixed wrong Removeable setting