home *** CD-ROM | disk | FTP | other *** search
/ The Best of Mecomp Multimedia 2 / MECOMP-CD-II.iso / amiga / scanner / scantek / readme < prev    next >
Encoding:
Text File  |  1998-05-24  |  11.8 KB  |  367 lines

  1.  
  2.                         ScanTek 3.11
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.           © Copyright 1995/96/97/98 Waldemar Zöhner
  10.              email: wzoehner@nuernberg.netsurf.de
  11.  
  12.                   Get It, Feel It, Love It
  13.  
  14.  
  15.  Overview
  16. ----------
  17.  
  18.  The ScanTek scanner driver has the following features:
  19.  
  20.  1. Support of the following SCSI Microtek scanner models:
  21.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  22.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  23.         Highscreen PerfectScan, Highscreen HighScan
  24.  
  25.     Support of the following SCSI Mustek Paragon scanner models:
  26.         Three Pass Scanners:
  27.         Paragon 6000CX, 8000CX (not tested), 12000CX all should work
  28.  
  29.         One or Single Pass Scanners:
  30.         Paragon 6000SP, 8000SP, 12000SP (now supported) all should work
  31.         Paragon 6000CZ, 8000CZ (not tested)
  32.  
  33.         Paragon 600IISP, 800IISP
  34.  
  35.  
  36.     The following scanner models are in the development phase:
  37.         Microtek E3PLUS
  38.            This new scanner model can be used in black&white, grey scale
  39.            and color scanning.
  40.            The download of color lookup tables (gamma curves) does not
  41.            work at the moment.
  42.  
  43.         Microtek V300 
  44.         Microtek 330, 630
  45.            These scanner models are due to the documentation related to           
  46.            the Microtek E3PLUS. They should work in an equivalent way.
  47.  
  48.  
  49.     The following scanner models are recognized but not fully supported: 
  50.         Mustek ScanExpress 12000SP
  51.         Mustek Paragon 1200IIISP (caution: III -> version 3)
  52.            Color scanning is only sucessfull at resolutions of 150, 300,
  53.            600 and 1200 dpi.
  54.            Grey scale scanning is possible.
  55.            If the image to be scanned exceeds the scan buffer size than
  56.            the image is corrupt. This effect is independent from the
  57.            scan mode.
  58.            The scanning quality is also (!) dependent from the used
  59.            SCSI host adapter.
  60.            The ScanExpress or Paragon 12000IIISP scanner models are
  61.            not recommended for ScanTek.
  62.            At least until sometimes in the future the corresponding
  63.            Mustek SCSI programming documentation for these new models
  64.            is available. I think this might be a Millenium projekt.
  65.  
  66.  
  67.     The following scanner models are not supported by now: 
  68.         All remaining Mustek ScanExpress and Paragon IIISP models.
  69.  
  70.  
  71.     The following scanner models are not supported:
  72.         Canon, Epson, HP, Umax and any parallelport scanner.
  73.  
  74.  
  75.     Attention: In recent times Mustek has changed the scanner firmware.
  76.                I urge you to test Mustek scanners with your Amiga
  77.                configuration before buying it.
  78.  
  79.                Mustek scanners have a critical SCSI interface. It
  80.                was reported to me that these scanners may not work
  81.                with the A2091 and A3000(T) internal SCSI interface.
  82.                It is possible that these scanners do not work with
  83.                other SCSI host adapters, either.
  84.                But the Mustek 6000CX and Paragon MFS-12000SP work in
  85.                combination with an Oktagon SCSI host adapter.
  86.                Be sure to disable reselection for Mustek scanners
  87.                on your SCSI host adapter. Otherwise your system may
  88.                not boot.
  89.  
  90.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  91.     three pass color scan, grey, red, green and blue scan.
  92.  
  93.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  94.     midtone, highlight, exposure time and scanning speed for download to the
  95.     scanner.
  96.  
  97.  4. Download of a color look up table (gamma correction table ) to the scanner
  98.     supported.
  99.  
  100.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  101.     the scanned image is independent from the RAM size. After the scanning
  102.     process it is possible to start an external program.
  103.  
  104.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  105.     but Kickstart 3.0 is recommended.
  106.  
  107.  7. Sizeable preview window in black/white or grey scale. Color preview
  108.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  109.     There are much more skilled programs to view and manipulate the scanned
  110.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  111.     want to do sophisticated postproduction)
  112.  
  113.  8. ARexx support
  114.  
  115.  9. Screenmode requester to define custom screen for working. The actual public
  116.     screen is supported as well
  117.  
  118.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  119.      connectable scanners.
  120.  
  121.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  122.      gvpscsi.device V4.5.
  123.  
  124.  12. ScanTek is written using SAS C 6.55.
  125.  
  126.  13. ScanTek is SHAREWARE.
  127.  
  128.  14. The non registered version of ScanTek is a full working version, but all
  129.      scanned images have black lines to motivate you to register.
  130.      Additionally the maximum size of the preview is restricted.
  131.  
  132.  
  133.  
  134.  History
  135. ---------
  136.  
  137.  V3.11 24 May 1998
  138.  
  139.    - Support of the new Highscreen HighScan II (Microtek) and
  140.      the new version of the Microtek E3Plus
  141.  
  142.  
  143.  V3.10 17 April 1998
  144.  
  145.    - First attempt to support the new Microtek 330 scanner model.
  146.      The scanning speed depends in a large degree on the SCSI host adapter.
  147.      This scanner model may lead to hang ups of the SCSI bus (computer
  148.      system) on critical SCSI devices.
  149.  
  150.  
  151.  V3.9  15 March 1998
  152.  
  153.    - Better support for Mustek ScanExpress 12000SP and the identical
  154.      international Mustek Paragon 1200 III SP.
  155.      This scanner model is not recommended for ScanTek.
  156.        Preview works now also on small preview windows.
  157.        Color scanning is only successful at resolutions of 150, 300,
  158.        600 and 1200 dpi.
  159.        Only small scanning images are successful. The automatic segment
  160.        scanning is not possible on this scanner model.
  161.  
  162.    - The new Microtek model ScanMaker E3PLUS is in the testing phase.
  163.      (see Overview for details)
  164.    
  165.    - Microtek V300, Microtek 330, Microtek 630
  166.        These scanner models are due to the documentation related to           
  167.        the Microtek E3PLUS. They should work in an equivalent way.
  168.  
  169.  
  170.  V3.8  23 February 1997
  171.  
  172.    - Bugfix of Mustek color scan process (Scrambled image data in
  173.      segment scanning)
  174.  
  175.    - Support of Transparency Adapter (Slide Kit Unit) enhanced
  176.  
  177.    - First attempt to support the new european Mustek
  178.      ScanExpress 12000SP and international Mustek Paragon 1200 III SP.
  179.      These scanners are assumed to be identical.
  180.      Due to missing Mustek programming documentation for the new firmware
  181.      there is only a limited support of these scanner models:
  182.        ... Gray scale scanning is supported.
  183.        ... Color scanning is incorrect and is therefore unusable
  184.      These scanner models are not recommended for the use with ScanTek.
  185.      If there will be a Mustek programming documentation some time in the
  186.      future than a second attempt for the support will be made.
  187.  
  188.  
  189.  V3.7  30 December 1997
  190.  
  191.    - Detection of Mustek scanners enhanced
  192.      Erkennung von Mustek Scannern weiterentwickelt
  193.  
  194.    - German Documentation
  195.      Deutsche Anleitung
  196.  
  197.  
  198.  V3.6  21 December 1997
  199.  
  200.    - The Mustek MFS-12000SP is now supported
  201.    - Rework of ASL requester handling
  202.    - PROGDIR: usage reduced
  203.  
  204.  
  205.  V3.5  4 December 1997
  206.  
  207.    - Rework of window activation procedures
  208.    - Rework of font sentivity
  209.    - PROGDIR: usage reduced
  210.    - Support of multiple SCSI host adapters in one system
  211.  
  212.  
  213.  V3.4  21 October 1997
  214.  
  215.    - Support of Transparency Adapter (Slide Kit Unit)
  216.    - Prevent system lockup during startup on Dataflyer SCSI+ host
  217.      adapter
  218.  
  219.  
  220.  V3.3   1 August 1997
  221.  
  222.    - Detection of ScanMaker35t+ introduced 
  223.    - Faster preview scanning process on some scanner models
  224.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  225.  
  226.  
  227.  V3.2   8 June 1997
  228.  
  229.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  230.    - AREXX scripts: Load scanned pictures into 
  231.                     ImageFX:   ST2ImageFX.strx
  232.                     ArtEffect: ST2ArtEffect.strx
  233.  
  234.  
  235.  V3.1  19 May 1997
  236.  
  237.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  238.    - Recognition of Highscreen RealScan (300dpi) introduced
  239.    - Activation of newly opened windows works now correct
  240.  
  241.  
  242.  V3.0   16 Apr. 1997
  243.  
  244.    - AREXX support
  245.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  246.      IFF File
  247.    - Handling of Microtek ScanMaker E6 enhanced
  248.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  249.                and some Mustek scanner models are now correct.
  250.                This bug could lead to images that where to light.
  251.                Grey preview of color image now work with all specified
  252.                settings.
  253.  
  254.  
  255.  V2.10 26 Mar. 1997
  256.  
  257.    - Full size preview on 400 dpi Mustek scanners adjustable
  258.  
  259.  
  260.  V2.9   9 Feb. 1997
  261.  
  262.    - Look Up Table Window redesigned to ensure font sensitivity
  263.  
  264.  
  265.  V2.8  11 Jan. 1997
  266.  
  267.    - New icons for ScanTek
  268.    - Recognition and handling of new Mustek scanners enhanced
  269.    - Minior bug fixes
  270.    - Introduction of the ScanTek Support WebSite
  271.  
  272.  
  273.  V2.7  6 Dec. 1996
  274.  
  275.    - Recognition and handling of new Mustek scanners enhanced
  276.    - Recognition of Microtek ScanMaker E6 adapted
  277.  
  278.  
  279.  V2.6  30 Oct. 1996
  280.  
  281.    - Full support of Mustek one pass scanners
  282.    - Recognition of Mustek scanners enhanced
  283.  
  284.  
  285.  V2.5  5 Oct. 1996
  286.  
  287.    - Workaround to handle strange color mode behaviour of Mustek
  288.      one pass scanners
  289.    - Reverse scanning in black and white mode introduced
  290.  
  291.  
  292.  V2.4 10 Sept. 1996
  293.  
  294.    - Support of Mustek SCSI one pass color scanners in color mode and
  295.      parameter ranges.
  296.    - ScanTek can now open its GUI windows on the actual public screen.
  297.  
  298.  
  299.  V2.3  6 Sept. 1996
  300.  
  301.    - Color Preview on Cybergraphix screens in true color mode
  302.      (15, 16 or 24 bit) for onepass flatbed scanners
  303.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  304.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  305.    - Change and recall of predefined resolution values
  306.  
  307.  
  308.  V2.2 26 July 1996
  309.  
  310.    - Enhanced support for Mustek scanners
  311.      "Exposure Time" and "Contrast" parameters are now correct
  312.    - Gamma value "All" now works on threepass scanner
  313.    - Alternative Black/White scanning mode
  314.  
  315.  
  316.  V2.1  5 July 1996
  317.  
  318.    - Preview now fully supported for Mustek 6000CX
  319.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  320.  
  321.  
  322.  V2.0  30 Apr. 1996
  323.  
  324.    - Preview in color mode with proper options values
  325.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  326.    - X and Y Aspect Ratio in color images is correct now
  327.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  328.    - Lookup Table command supported (Gamma Correction on certain scanner
  329.      possible)
  330.    - Scanning Frame Setting is now more intuitive
  331.    - Reverse image scanning supported (only on certain scanners possible)
  332.    - Accurate scanning supported. Scanning frame is now more precise.
  333.  
  334.  
  335.  V1.3  25 Feb. 1996
  336.  
  337.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  338.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  339.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  340.    - No start of the external program, if the scanning process is aborted
  341.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  342.      Preview image should look better now.
  343.    - "Main Control" window and gadgets modified
  344.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  345.  
  346.  
  347.  V1.2   3 Jan. 1996
  348.  
  349.    - Debug output data revised and enhanced
  350.    - Max Frame Setting setting introduced
  351.    - Start of external program possible
  352.    - Window positions are remembered and saved
  353.    - Configuration file enhanced
  354.  
  355.  
  356.  V1.1  17 Dec. 1995
  357.  
  358.    - detection of Microtek scanner via SCSI inquiry enhanced
  359.    - stepping of resolution slider adapted to expanded base resolution
  360.    - calculation of scanning frame size data modified
  361.  
  362.  
  363.  V1.0  30 Nov. 1995
  364.  
  365.    - first public release
  366.  
  367.