  1.  
  2.  
  3.             RADIO-FREQUENCY RADIATION CALCULATION PROGRAM*
  4.  
  5.                              (*RFCALCS)
  6.  
  7.  
  8.    THIS PROGRAM IS BASED UPON AIR FORCE OCCUPATIONAL SAFETY AND
  9. HEALTH (AFOSH) STANDARD 161-9, DATED 12 OCTOBER 1984.
  10.  
  11.    THIS PROGRAM IS USED TO HELP TO DETERMINE IF A PARTICULAR RF
  12. (RADIO-FREQUENCY) EMITTER IS HAZARDOUS, POTENTIALLY HAZARDOUS, OR
  13. NON-HAZARDOUS TO PERSONNEL EXPOSED TO ITS ENERGY.
  14.  
  15.  
  16. CODES FOR PROGRAM:
  17.  
  18. 1) ANTENNA CODES:
  19.  
  20.    BL -- BLADE
  21.    CR -- CIRCULAR REFLECTOR
  22.    DC -- DISCONE
  23.    DI -- DISCAGE
  24.    DL -- DUMMY LOAD
  25.    DP -- DIPOLE OR DIPOLE ARRAY
  26.    ER -- ELLIPTICAL REFLECTOR
  27.    HE -- HELIX
  28.    HL -- HORIZONTAL LOG PERIODIC
  29.    HO -- HORN
  30.    LE -- LENS
  31.    LO -- LOOP
  32.    MO -- MONOPOLE OE COLINEAR ARRAY
  33.    OD -- OTHER, DIRECTIONAL
  34.    OO -- OTHER, OMNIDIRECTIONAL
  35.    PA -- PHASED ARRAY
  36.    RH -- RHOMBIC
  37.    RR -- RECTANGULAR REFLECTOR
  38.    SL -- SLOT / SLOT ARRAY
  39.    ST -- STUB
  40.    VL -- VERTICAL LOG PERIODIC
  41.    WH -- WHIP
  42.  
  43. 2. SCANNING CODES:
  44.  
  45.    E -- SECTOR SCAN (ELECTRONIC)
  46.    F -- FIXED
  47.    R -- ROTATING (360 DEGREES)
  48.    S -- SECTOR SCAN (MECHANICAL)
  49.    T -- TRACKER
  50.  
  51. 3. HAZARD CODES:
  52.  
  53.    CH -- HAZARD LEVELS POSSIBLE,  BUT OLNY IN AREAS THAT REQUIRE 
  54.          CLIMBING.
  55.    DL -- TRANSMITTER DUMMY LOADED.
  56.    GH -- GROUND-LEVEL HAZARDOUS EXPOSURES POSSIBLE.
  57.    IH -- HAZARDOUS LEVELS POSSIBLE, BUT IN NORMALLY INACCESSABLE
  58.          AREAS.
  59.    MD -- MEDICAL DEVICE; NO LEVELS GENERATED IN EXCESS OF PEL.
  60.    MH -- MEDICAL DEVICE; LEVELS GENERATED IN EXCESS OF PEL.
  61.    HN -- NO LEVELS GENERATED IN EXCESS OF PEL
  62.    SH -- TIME IS TOO SHORT OR INHERENT EQUIPMENT LIMITATIONS MAKE
  63.          OVEREXPOSURE UNLIKELY OR IMPOSSIBLE.
  64.  
  65. 4. SYSTEM CONTROL CODES:
  66.  
  67.    AS -- AUDIBLE SIGNAL
  68.    BA -- ROPE OR CHAIN BARRIER
  69.    CO -- CONSTANT OBSERVATION WHEN TRANSMITTING
  70.    FE -- FENCE
  71.    FL -- FLASHING LIGHTS
  72.    NR -- NO CONTROLS REQUIRED
  73.    OM -- OTHER
  74.    SC -- SPECIAL COORDINATION WHEN TRANSMITTING
  75.    SO -- STANDARD OPERATING PROCEDURE IN EFFECT
  76.    WS -- WARNING SIGNS
  77.  
  78. TABLE 1 -- MAXIMUM PERMISSIBLE EXPOSURE LIMITS (PEL'S) FOR  HUMAN 
  79. EXPOSURE TO RADIO-FREQUENCY RADIATION. AVERAGED OVER ANG 6 MINUTE 
  80. PERIOD.**
  81.  
  82. ________________________________________________________________
  83.     FREQ               PEL FOR AVG.            PEL FOR SMALL
  84. FROM     TO             SIZE ADULT              SIZE HUMAN
  85. MHZ      MHZ           (mw/sq.cm.)             (mw/sq.cm.)
  86. ________________________________________________________________
  87. .01        3                100                    100         
  88.   3       30              900/f2                  900/f2
  89.  30      100                 1                      1
  90. 100      300               f/100                    1
  91. 300     1000               f/100                  f/300
  92. 1000    1500                 10                   f/300
  93. 1500   300000                10                     5
  94.  
  95. **    -- OBTAINED   FROM   AFOSH   STANDARD   161-9 "EXPOSURE  TO 
  96. RADIOFREQUENCY RADIATION", DATED 12 OCTOBER 1984.