  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 881
  16. MODEL: TS-930S
  17. SUBJECT: POWER SUPPLY SURGE PROTECTION
  18.  
  19. A line surge (exceeding approximately 4.5KV) due to static electricity 
  20. or nearby lightning discharge may short power relay diode,D2 (V06E), 
  21. and cause electrolytic capacitor C14 (3.3 uf) to break down. 
  22. This results in relay chatter and the relay contacts may finally weld.
  23.  
  24. Addition of the surge absorber to the primary power supply input circuit, 
  25. should help avoid this type of failure.
  26.  
  27. NOTE: This symptom has occasionally occurred in those limited areas 
  28.       subject to frequent and violent lightning discharges. 
  29.       A good earth ground and antenna system lightning protection is 
  30.       still strongly recommended.
  31.  
  32.  
  33. ADD PART D9 (ERZClODK431) ACROSS THE AC LINE INPUT 
  34.  
  35. Note: This change applies to units before S/N 3080301.
  36.  
  37.