home *** CD-ROM | disk | FTP | other *** search
/ World of Ham Radio 1997 / WOHR97_AmSoft_(1997-02-01).iso / mods / kenwood / asb_text / asb0817.txt < prev    next >
Text File  |  1997-02-01  |  2KB  |  44 lines

  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 817
  16. MODEL: TS-180S
  17. SUBJECT: USE WITH A LINEAR AMPLIFIER
  18.  
  19.  
  20. 1.   Fast Protection with a Linear:
  21.  
  22.      For complaints of fast protection, such as when operating CW semi-
  23. break-in with a linear, check C73 at the base of Q1 on the LPF unit X51-
  24. 1180-00.  If it is a 1uf, change to 3.3 uf, 25v or greater.  This will
  25. compensate for slow linear relay closure.
  26.  
  27. 2.   Premature Protection
  28.      
  29.      The radio should protect at 3:1 SWR, or at 24W open (no) load.  To
  30. test the protection circuit, load the radio at 24W into a know 500 ohm
  31. dummy load through a Bird 43 wattmeter.  Disconnect the load from the
  32. wattmeter.  The protection light should just lite.  Adjust the protection
  33. pot VR1 on the LPF unit for protectio at 24W with no load.
  34.  
  35. 3.   For complaints of VOX CYCLING, MEMORY JUMP, READOUT JUMP, or TONE
  36. "BEEP" at key up or down with a linear amp, suspect linear induced relay
  37. transients entering the radio via the ASSY relay wiring.
  38.  
  39.      For example, DRAKE L4B linears before Serial Number 5500 do not have a
  40. quench diode across the DC operated relay.  Install a 1N4005 or equivalent
  41. across the relay in the linear to eliminate the back EMF induced by the
  42. linear into the TS-180S.  Similarly, Henry linears also don't have a diode
  43. across the relay and may give these symptoms when operated with a TS-180S.
  44.