  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 43
  16. MODEL: TS-520S
  17. SUBJECT: -6 VOLT DC POWER SUPPLY FAILURE
  18.  
  19.  
  20. When troubleshooting a TS-520S, check all power supply voltages, including
  21. the -6v DC supply.  Symptoms such as dead, blown 2A DC fuse and now dead,
  22. low RX, no TX, or similar may occur after switching between 80 and 40M.
  23.  
  24. Cause of failure may be traced to an intermittent shorting between the 14v
  25. dc and -6 dc supplies as the band switch is rotated between 40 and 80
  26. meters.  This will weaken or destroy D8, a 6v zener on the FIX CH AVR unit.
  27. To prevent repeat failures, break the White lead and install a 22 K ohm 1/2
  28. watt resistor at the bandswitch S5-6, between the -6v supply line and
  29. switch terminal.  An of course replace D8 on the FIX CH AVR unit, X43-1100-
  30. 00
  31.  
  32. New Part:  22 k ohm 1/2 W carbon resistor
  33.  
  34. Please annotate your service manual.