home *** CD-ROM | disk | FTP | other *** search
/ World of Ham Radio 1997 / WOHR97_AmSoft_(1997-02-01).iso / mods / kenwood / asb_text / asb0028.txt < prev    next >
Text File  |  1997-02-01  |  3KB  |  66 lines

  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 28
  16. MODEL: DG-5
  17. SUBJECT: REPAIR OF UNIT
  18.  
  19.  
  20. 1. Symptoms:  Two dots on LED display
  21.    Check:  Het input and VFO input connections (Dirty, intermittent, 
  22.    missing.)
  23.  
  24. 2. Display reading wrong frequency
  25.    Check:  If display frequency is reading off by 2 MHz and last 
  26.    four digits on display reading (894.9) check carrier input wire 
  27.    (Dirty, missing, intermittent.)
  28.  
  29. 3. No display or dim display
  30.    Check:  5v reg (IC power) not working or plated thru holes not 
  31.    plated thru.
  32.  
  33.  Above are common mechanical failures that occur with DG-5.  We suggest 
  34.  the following troubleshooting procedure:
  35.  
  36.  Check:    
  37.  
  38.   A. Power all power supply levels.
  39.   B. Reference oscillator Q21 and divider chain IC5-11 (RF, waveforms, DC.)
  40.   C. Carrier, VFO and HET, also counter (When applicable) for RF, Waveforms 
  41.      and DC levels; see service manual for proper levels.
  42.  
  43. Note: Operation of the circuits are essential before proceeding.
  44.  
  45. It's been Kenwoods experience that when problems do occur with the DG-5 
  46. that approximately 90% of the problems will be caused by insufficient 
  47. solder connections and not the actual components themselves.
  48.  
  49. Note: We suggest the following procedure if buffers, mixers and oscillators 
  50.       are working properly:  See service manual for proper levels.
  51.  
  52.  Check:    
  53.  
  54.    A. All sloder connections (loose or cold.)
  55.    B. Solder all plated thru holes:  32 guage wire inserted in plated 
  56.       thru holes takes approximately 30 minutes to do and is very, 
  57.       very, effective.
  58.  
  59. Service Suggestion:
  60.  
  61.  A heat gun and freeze spray often are very effective in locating cold 
  62.  or not-plated thru holes.
  63.  