  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 7
  16. MODEL: T-599D
  17. SUBJECT: SERVICE NOTES
  18.  
  19. 1.  No ALC - Drive 10 Meters: Check for loose contact at
  20.     oscillator wafer on coil pack.
  21.  
  22. 2.  No TX any band:  Check T-1 on generator board 
  23.     (X52-0009-00).
  24.  
  25. 3.  No TX:  Bad driver FET Q1 3SK22 (GR) on X47-0004-00.
  26.  
  27. 4.  No relay action when TX:  Bad Q8 2SA562 (Y).  When 
  28.     replacing Q8 change resistor R16 to 4.7 ohms.
  29.  
  30. 5.  Rubber belt slipping on drive and load.  TKC has chain
  31.     modification kit.
  32.  
  33. 6.  No drive when shock:  Check for loose output terminal at 
  34.     carrier unit (X50-0002-00).
  35.  
  36. 7.  Low Power 75 Meters:  Check for shorting terminals at
  37.     final rotary switch (S10-1002-05).
  38.  
  39. 8.  No output on any band:  Check T-2 on GEN unit (X42-0009-00).
  40.  
  41. 9.  No TX:  Check final relay for burned contacts.  (S51-4017-15).
  42.  
  43. 10. Bias current too high and blows fuse.  Check for bad S-2001A and
  44.     shorted cathode resistors, 10 ohm.
  45.  
  46. 11. Cannot neutralize:  Make sure shield is properly installed on driver
  47.     12BY7A.
  48.  
  49. 12. No output from generator unit (X52-0009-00):  Bad Q4 TA7045.
  50.  
  51. 13. No 9 volt out at AVR (X43-010-00):  Check Q1 2SA606 (L).
  52.  
  53. 14. Low output power:  If American 12BY7 is used in driver circuit, this
  54.     can cause parasitic oscillation.  Please use standard Kenwood
  55.     replacement tubes.
  56.  
  57. 15. Blows Fuse:  Check for shorted electrolytics at power supply 
  58.     (X43-011-00).