home *** CD-ROM | disk | FTP | other *** search
/ Shareware 1 2 the Maxx / sw_1.zip / sw_1 / TEXT / SUPRAMSG.ZIP / SUPRAMSG.TXT < prev   
Text File  |  1992-06-27  |  280KB  |  7,236 lines

  1. 2
  2.  
  3.  
  4. Reading Message Board *GENERAL*
  5. Section has 96 Msgs, #311 to 1318 
  6.  
  7. Starting number, <CR>=First: 
  8.  
  9.  
  10. Msg#:  311 *GENERAL*
  11. 05-29-92 10:35:02
  12. From: SYSOP
  13.   To: HOWARD JIANG
  14. Subj: SHIPPING DATE
  15. Howar, I am checking on your order. [Nathan]
  16.  
  17.  
  18. Msg#:  619 *GENERAL*
  19. 06-09-92 15:38:59
  20. From: GLENN LOFTUS
  21.   To: HOWARD JIANG
  22. Subj: REPLY TO MSG# 178 (SHIPPING DATE)
  23. Howard--
  24.  
  25.   I, too, am very dissapointed to see the Sysop post lies here about delievery
  26. times.  I would be much happier if he would just post honest answers to the
  27. question of "When?"
  28.  
  29.   I ordered a V.32bis SupraFAXmodem some 4 months ago.  It actually started
  30. shipping 2.5 months ago.  The mail-order firm from whom I ordered it _still_
  31. hasn't received any modems direct from Supra, though they have gotten a trickle
  32. from other distributors.
  33.  
  34.   While it may be in the short-run interest to string us along with promises of
  35. "just a few weeks more", rather than having some of us cancel our orders and go
  36. buy a competing product which is readily available, I believe that this
  37. business practice hurts Supra's image in the long run.
  38.  
  39.   However, at this point, I've already waited for over 1/3 of a year, and I'm
  40. too stubborn to cancel my order now.  I'll simply keep up my currect practice
  41. of checking with the mail-order firm, on this BBS, and with Supra's sales
  42. department every couple weeks to see if things are getting any better.
  43.  
  44.                                                 --Glenn...
  45.  
  46.  
  47. Msg#:  741 *GENERAL*
  48. 06-13-92 11:33:58
  49. From: MARK WHITE
  50.   To: GLENN LOFTUS
  51. Subj: REPLY TO MSG# 619 (SHIPPING DATE)
  52. We do not lie.  It is virtually impossible for anyone to give an accurate, to
  53. the day, assessment as to when the product will ship out.  We have a large back
  54. order of product, when we state a few weeks for delivery, we are making every
  55. attempt to give a fairly accurate guessament.  But we are basing our estimate
  56. off of what date we are currently shipping from, what has been our progress
  57. until them, and a large guess.  Shipping can be affected by many different
  58. events, suppliers, new code, etc.
  59.  
  60. As far as your dealer having an order from supra and it not being shipped.  If
  61. the order is for stand-alone units, I believe that is incorrect.  My
  62. understanding is that we have shipped to ALL dealers that have orders from us.
  63. We have been shipping partial orders to all dealers so that everyone has
  64. received at least a few units.  
  65.  
  66. Now if the orders are for units with fax software, then that may be correct as
  67. we have only started production of the fax packages in the last few weeks.
  68.  
  69. Mark - Supra Tech Support
  70.  
  71.  
  72. Msg#: 1012 *GENERAL*
  73. 06-20-92 15:38:04
  74. From: JOE QUILICI
  75.   To: GLENN LOFTUS
  76. Subj: REPLY TO MSG# 619 (SHIPPING DATE)
  77. What's particularly disheartining is the number of complaints against Supra,
  78. and the lack of complaints agains other manufacturers such as Boca which are
  79. not only cheaper, but reputably of higher quality...
  80.  
  81.  
  82. Msg#: 1025 *GENERAL*
  83. 06-20-92 22:05:12
  84. From: MARK WHITE
  85.   To: JOE QUILICI (Rcvd)
  86. Subj: REPLY TO MSG# 1012 (SHIPPING DATE)
  87. All manufactores using the Rockwell RC144AC chipset (Zoom VFX, Pratical
  88. Peripherals FXSA, Quicktel ect.) Are having the same problems.  ONLY Supra has
  89. implemented a fix, which will be sent out FREE to all registered owners mid
  90. july.  Supra has also licensed the code to Rockwell, so the other manufactores
  91. using this chipset will have the fix late this year.
  92.  
  93. According to the June 92 BoardWatch list of retail and sysop prices on V32 and
  94. v32bis modems, Supra has the LOWEST retail and sysop price of 15 manufactors.
  95. We have run exhaustive tests on our competetors and have read everything we can
  96. on CIS, GEnie, competetors BBSes.  Other than our modem not having an optional
  97. feature of v32bis (initiation of fallback under adverse line conditions), we
  98. feel that we have a very competitive product, in terms of performance,
  99. reliability and cost.  And our tens of thousands of happy customers can atttest
  100. to this.  Some people have had problems, but Supra has responded.  Our FedEx
  101. program, implementing optional features of v32bis, fixing several bugs in
  102. Rockwells code.  (Our ROM code is the ONLY one to support ECM.  We fixed
  103. several of Rockwells bugs to fix this one.)
  104.  
  105. Mark - Supra Tech Support
  106.  
  107.  
  108. Msg#:  332 *GENERAL*
  109. 05-30-92 21:09:09
  110. From: PETER WILD
  111.   To: TECH SUPPORT
  112. Subj: SUPRA TO SUPRA
  113. hi there.having problem connecting to other supra 14.4 modems.is this a;so 
  114. going to be fixed with the rom upgrade that i need for winfax pro.i left a
  115. message but didn`t get a response yet......don`t have problem connecting to any
  116. other brand of 14.4 modem .....I also have a problem connecting to your BBs why
  117. i don`t know......i can be reach here on your bbs or at my office at
  118. 503-641-6644....thanks pete
  119.  
  120.  
  121. Msg#:  345 *GENERAL*
  122. 05-31-92 23:17:08
  123. From: MARK WHITE
  124.   To: PETER WILD
  125. Subj: REPLY TO MSG# 332 (SUPRA TO SUPRA)
  126. Yes, the new ROM which works with winfax also has the ability to initiate a
  127. drop in baud.
  128.  
  129.  
  130. Msg#:  534 *GENERAL*
  131. 06-07-92 10:31:44
  132. From: EITAN ADUT
  133.   To: MARK WHITE (Rcvd)
  134. Subj: REPLY TO MSG# 345 (SUPRA TO SUPRA)
  135. when can I get the new rom? I already sent that stupid card in... I want the
  136. rom.... plus I want MNP 10 what is taking so long!!!!!
  137.  
  138.  
  139. Msg#:  554 *GENERAL*
  140. 06-07-92 23:02:54
  141. From: MARK WHITE
  142.   To: EITAN ADUT
  143. Subj: REPLY TO MSG# 534 (SUPRA TO SUPRA)
  144. We will be sending the new ROM at no charge to all registered owners on July
  145. 15.
  146.  
  147. Mark Supra Tech Support
  148.  
  149.  
  150. Msg#:  680 *GENERAL*
  151. 06-11-92 20:59:49
  152. From: KEVIN O'CONNOR
  153.   To: MARK WHITE (Rcvd)
  154. Subj: REPLY TO MSG# 554 (SUPRA TO SUPRA)
  155. JULY 15!?!?!? What happened to mid-June???! Or is that just a typo?
  156.  
  157.  
  158. Msg#:  735 *GENERAL*
  159. 06-13-92 11:04:30
  160. From: MARK WHITE
  161.   To: KEVIN O'CONNOR (Rcvd)
  162. Subj: REPLY TO MSG# 680 (SUPRA TO SUPRA)
  163. We never said mid-June for impelmentation of fall back.  The ONLY date we have
  164. ever given for new roms was the end of may for those people with fax software.
  165.  
  166. Mark - Supra Tech Support
  167.  
  168.  
  169. Msg#:  844 *GENERAL*
  170. 06-15-92 23:11:33
  171. From: KEVIN O'CONNOR
  172.   To: MARK WHITE (Rcvd)
  173. Subj: REPLY TO MSG# 735 (SUPRA TO SUPRA)
  174. I guess I also forgot to mention that the 1600 cps was a ZIPed file. I've been
  175. using modems for quite some time, and I've never seen a modem successfully
  176. compress an already compressed file. The cps rates were reported both by the
  177. PCBoard software sending the files, and my DSZ Zmodem driver receiving.
  178.  
  179. I understand that the reported CPS is not an accurate representation of the
  180. actual rate going over the phone line. But, a ZIPed file should, if anything,
  181. cause the CPS rate measured by transfer software to be LOWER  than the actual
  182. line rate. This being the case, I was getting at least a 14.4 baud connection.
  183.  
  184. And how can you explain the fact that this modem will continuously connect at
  185. 14.4 but come up with a protocol of NONE, while the other side thinks the
  186. connection is LAP-M (and 14.4)?
  187.  
  188.  
  189. Msg#:  374 *GENERAL*
  190. 06-02-92 08:22:40
  191. From: SYSOP
  192.   To: AHMED ELAWADI
  193. Subj: CANADIAN CUSTOMS
  194. We have been in contact with the Canadian authorities, and plan to have
  195. everything cleared to ship modems to Canada by the end of the month. [Nathan]
  196. Supra Technical Support
  197.  
  198.  
  199. Msg#:  379 *GENERAL*
  200. 06-02-92 08:35:22
  201. From: SYSOP
  202.   To: LIEM LE
  203. Subj: SUPRAFAXMODEM V.32BIS 14400
  204. This will be too difficult to solve here.  If you haven't already talked to
  205. tech support over the phone, then this is the best solution.  Will it connect
  206. at slower speeds?  I assume this is on an IBM compatible system.  What is your
  207. init string?  It should start with AT &F2, and then you can modify it from
  208. tthere.   [Nathan]
  209.  
  210.  
  211. Msg#:  392 *GENERAL*
  212. 06-02-92 12:25:56
  213. From: JIM WALLACE
  214.   To: SYSOP (Rcvd)
  215. Subj: HELP!!!!!
  216. Dear Supra,
  217.  
  218.         I purchased three of your V.32bis modems.  I have had no problems
  219. utilizing them to originate calls to other high-speed BBS systems, and
  220. sending/receiving FAXes (with the MOD.EXE in windows...), however, when I try
  221. to connect two SUPRA modems together, they connect, and then immediately drop
  222. off and hang up.  I have tried everything in the book in attempts to make it
  223. connect.  I have a lot of experience with setting up modems, so I know I'm not
  224. just blowing steam.
  225.  
  226.         I understand there is a new ROM chip coming out in mid June, which is
  227. supposed to fix the MOD.EXE problem... Will it also fix the V.32bis problems as
  228. well?
  229.  
  230.         Another problem which I am experiencing is when I try to originate or
  231. answer a call from a 2400 BAUD modem that DOES NOT support MNP protocols.  I
  232. have several older (1.5 yrs) 2400 baud modems that I cannot connect to unless I
  233. use AT&F0, but then I lose the ability to make or receive calls using V.32bis
  234. with compression & data correction, etc.. I get the same result with an
  235. authentic HAYES 2400 baud external modem (also older style, no MNP).  I have no
  236. problems at all calling PRODIGY or AMERICA ONLINE at 2400 baud, even when I
  237. have AT&F2 set.  The modem reports "M3" or "M4" on the front display when I
  238. call these systems.
  239.  
  240.         I would greatly appreciate a call back regarding these matters.  I have
  241. heard A LOT of GREAT comments about your modem from friends, and people in the
  242. business.  I am beginning to wonder how they had such good luck....?   I am
  243. just about ready to give up, and try out GALAXY's latest&greatest...  Please
  244. contact me as soon as possible at (310) 434-1556, and ask for ERIC, or CHRIS.
  245.  
  246. If you could call me back today (June 2), I am in NAPwv.Mva^OjZAx{}~R/?O~}@ 3tA
  247. m-zWfoW^8ht/    58*?,TTCdZ+c;n;lE{][|J6~vy\i6j)PSl o0
  248. %>$d:;bGapf!xE2`!v@5r(d
  249. &3^0ZY)R[-d_wvdjGSly:g!K 
  250. O\8"!!/gyu^%uyJSKuWuL1?TjfA1%B_d]>,O-iBHg&M}_=7FJ4=K6]UL]E!AZI#q,]moxE$.[Kr
  251. 1UXiokvzH1.m$[e&c_kWg[nz        Kd)~    z5Mn<F;E%ec{R~;\[4)o\0*~j,`     
  252.  
  253.  
  254. Msg#:  804 *GENERAL*
  255. 06-15-92 09:12:30
  256. From: SYSOP
  257.   To: JIM WALLACE
  258. Subj: REPLY TO MSG# 392 (HELP!!!!!)
  259. Jim, I'll give you a call.  The new ROM should clear up these problems.  To
  260. connect to non-MNP 2400 modems, set the speed to 2400 rather than cut error
  261. correction etc with AT &f0.  The command you need is: (AT N s37=6).  That
  262. should work. [Nathan]  Supra Technical Support
  263.  
  264.  
  265. Msg#: 1013 *GENERAL*
  266. 06-20-92 15:41:27
  267. From: JOE QUILICI
  268.   To: JIM WALLACE
  269. Subj: REPLY TO MSG# 392 (HELP!!!!!)
  270. When are the new ROM upgrades going to be made available?  I haven't received a
  271. single notice since mhase of my Supra v.32bis fax modem.
  272.  
  273.  
  274. Msg#:  404 *GENERAL*
  275. 06-02-92 17:19:29
  276. From: SYSOP
  277.   To: DAVID STARR
  278. Subj: HARD DRIVE
  279. David, Make sure that you have sent in your registration card for the modem.
  280. For the drive, I will look that up and get back to you.  [Nathan]  Supra
  281. Technical Support
  282.  
  283.  
  284. Msg#: 1163 *GENERAL*
  285. 06-23-92 15:39:03
  286. From: BRIAN WATTERS
  287.   To: DAVID STARR
  288. Subj: REPLY TO MSG# 262 (HARD DRIVE)
  289. call Maxtor's BBS at 303-678-2222 they have a listing of there hard specs!
  290. /s
  291.  
  292.  
  293. Msg#:  426 *GENERAL*
  294. 06-03-92 11:45:52
  295. From: JEFF MAUZEY
  296.   To: SYSOP (Rcvd)
  297. Subj: ROM UPGRADE
  298. Please Sign me up for the ROM upgrade, Thank you. Jeff Mauzey, 1347 S.W. 348th
  299. Street. Federal Way, WA. 98023.
  300.  
  301.  
  302. Msg#:  822 *GENERAL*
  303. 06-15-92 10:43:59
  304. From: SYSOP
  305.   To: JEFF MAUZEY (Rcvd)
  306. Subj: REPLY TO MSG# 426 (ROM UPGRADE)
  307. Jeff, OK. You are on the list.  We will send them to you soon. Supra Technical
  308. Support.
  309.  
  310.  
  311. Msg#:  439 *GENERAL*
  312. 06-03-92 12:38:11
  313. From: KEN STAIR
  314.   To: SYSOP (Rcvd)
  315. Subj: GREAT MODEM!
  316.  The 14.4 modem works ggreat. Yhe setting are a little trickey but work well.
  317. Thetri
  318.  
  319.  
  320. Msg#:  823 *GENERAL*
  321. 06-15-92 10:57:42
  322. From: SYSOP
  323.   To: KEN STAIR (Rcvd)
  324. Subj: REPLY TO MSG# 439 (GREAT MODEM!)
  325. Ken, Glad to hear that you like your new modem.  Please let me know if you have
  326. any questions. [Nathan]  Supra Technical support
  327.  
  328.  
  329. Msg#:  474 *GENERAL*
  330. 06-04-92 20:10:35
  331. From: FRED KOLBRENER
  332.   To: SYSOP (Rcvd)
  333. Subj: MODEM CABLE
  334. The manual supplement (blue printed sheets) states that a serial cable that
  335. makes use of hardware flow control is needed and says that one is available
  336. from you at $19.95.  Does this mean tha the cable supplied with my modem is not
  337. that kind?  It has no special markings on it.  I have been successful in
  338. getting to connect to your board(obviously), but not fully automatically.
  339. ProComm Plus does not seem to be talking fully to the automatically.  Day Phone
  340. is (703) 695-0879/9866.                          Have I got to add to the
  341. result messages in the program?  I tried to so so, but auto logon scripts don't
  342. run as they should.  2400 did logon OK.
  343.  
  344.  
  345. Msg#:  832 *GENERAL*
  346. 06-15-92 11:43:20
  347. From: SYSOP
  348.   To: FRED KOLBRENER (Rcvd)
  349. Subj: REPLY TO MSG# 474 (MODEM CABLE)
  350. You need a hardware handshaking cable.  The calbe we mentioned is for Macintosh
  351. owners, for $19.95.  (Many Macintosh computers were not sold with this kind of
  352. cable).  If you have an IBM compatible, and you can make high-speed
  353. connections, then you do have a hardware cable.  Make sure that pins 1 thru 8
  354. and 20 are connected.  (Standard RS 232 cable).  If you hve any more
  355. questiions, please let me know. [Nathan]  supra Technical support
  356.  
  357.  
  358. Msg#:  916 *GENERAL*
  359. 06-17-92 13:14:23
  360. From: FRED KOLBRENER
  361.   To: SYSOP
  362. Subj: REPLY TO MSG# 832 (MODEM CABLE)
  363. Nathan: I tried you number and got voice mail.  Today is the first day that I
  364. have been able to get thru to the BBS lately.  I agree with you - I must have
  365. the proper cable as I can call in at 9600 on most boards.  The limit now is the
  366. oldness of my compuyter which will soon be updated.  The manual was not clear.
  367. It implied that you did not supply the right cable.  I can't quote the specific
  368. places right now, but it was a question.  I have been generally successful with
  369. getting the connections for all but a few local boards.  I have achieved baud
  370. rates just slightly in excess of 9600 due to the port, but the modem connects
  371. at up to 14400.  Are most standard modem cables for the IBM compatibles able to
  372. be used with the modem?  I have used yours, but I have a longer one that I used
  373. with my 2400 ?   You can call me at home after 6:30 ESDT at 703-590-4269.
  374.  
  375. Thanks.
  376.  
  377. Phred
  378.  
  379.  
  380. Msg#:  475 *GENERAL*
  381. 06-04-92 20:52:35
  382. From: MICHAEL FURLICK
  383.   To: SYSOP (Rcvd)
  384. Subj: NEW PURCHASE
  385. I just purchased the Suprafax v32bis modem and am quite happy with it so far.
  386. Of course, I have not been able to test the fax portion yet (I have just
  387. downloaded the necessary zip file to correct the bug(s)). The only piece of
  388. advise I can offer now is this:  Place the needed modem settings in your
  389. documentation for communicating with this BBS.  I finally got through
  390. (obviously), but it took 4 attempts before I hit upon the correct settings
  391. (e,7,2).
  392. -Mike-
  393.  
  394.  
  395. Msg#:  523 *GENERAL*
  396. 06-06-92 21:41:34
  397. From: BRIAN DHATT
  398.   To: MICHAEL FURLICK
  399. Subj: REPLY TO MSG# 475 (NEW PURCHASE)
  400. I connect here at 8N1.
  401.  
  402.  
  403. Msg#:  833 *GENERAL*
  404. 06-15-92 11:46:13
  405. From: SYSOP
  406.   To: MICHAEL FURLICK
  407. Subj: REPLY TO MSG# 475 (NEW PURCHASE)
  408. Michael, you connected with E, 7, 2 ??  It should be 8/N/1.  Set your modem to
  409. 9,600 before calling this board with (AT N S37=9)  Or just try it again at full
  410. speed with 8/N/1.  Either way should work. [Nathan]  Supra Technical Support
  411.  
  412.  
  413. Msg#:  999 *GENERAL*
  414. 06-20-92 05:25:04
  415. From: RICHARD HORNING
  416.   To: MICHAEL FURLICK
  417. Subj: REPLY TO MSG# 475 (NEW PURCHASE)
  418. Does the BBS run compressed, or straight, when it comes to downloads. The
  419. reason I ask is that the down load times I experienced are  significantly
  420. longer than what was estimated.
  421.  
  422.  
  423. Msg#:  482 *GENERAL*
  424. 06-05-92 03:27:59
  425. From: ROBERT BENNETT
  426.   To: SYSOP (Rcvd)
  427. Subj: NEW ROM
  428. Hello Sysop, I am having problems transmitting faxes with my new Suprafax V.32
  429. bis and WinFaxPlease send me the new Rom when available. Also is there Is there
  430. Windows faxing software available thriogh you? at only $30 dollars? If so I
  431. would also be intersested in that if it will help my situation. Thanks! 
  432. Suprafax V.32bis S/N:14E003646 Robert H. Bennett 2098 Butler Pike, #N-23 
  433. Plymouth Meeting, PA  19462 (215) 941-6717
  434.  
  435.  
  436.  
  437.  
  438. Msg#:  854 *GENERAL*
  439. 06-16-92 08:17:13
  440. From: SYSOP
  441.   To: ROBERT BENNETT (Rcvd)
  442. Subj: REPLY TO MSG# 482 (NEW ROM)
  443. Robert, I will have those chips sent out to you.  We do sell Winfax 2.0.  The
  444. cost is $30.00.  If you already have Winfax, this will probably not be of
  445. interest to you. [Nathan]  Supra Technical Support
  446.  
  447.  
  448. Msg#:  486 *GENERAL*
  449. 06-05-92 13:46:58
  450. From: MATT BAKER
  451.   To: ROBERT HAYWARD
  452. Subj: SOFTWARE UPGRADE
  453. Hi Rob. See that you are on the board! Do you remember me? (g)
  454.  
  455. * Matt
  456.  
  457.  
  458. Msg#:  509 *GENERAL*
  459. 06-06-92 12:33:41
  460. From: JIM SANCHEZ
  461.   To: SYSOP (Rcvd)
  462. Subj: NEW ROM?
  463. I just received my suprafax v32bis modem yesterday from computability and have
  464. noticed that you mention a rom upgrade.  Will I be informed of this
  465. automatically or will I have to bug you about it.  Finally, what does it do?  I
  466. have not been able to connect to this system with the new modem but am using an
  467. old one at work.  What is the mystery setup for connecting to this system?  I
  468. tried the default at&f0 but that did not do it either.  What happens is either
  469. I get a connect message and nothing comes back or if I change to at&q6 I get
  470. the connect and a bunch of scrambled characters.   What gives? Thanks (my
  471. registration is in the mail - I Promise) Jim Sanchez
  472.  
  473.  
  474. Msg#:  524 *GENERAL*
  475. 06-06-92 21:43:25
  476. From: BRIAN DHATT
  477.   To: JIM SANCHEZ (Rcvd)
  478. Subj: REPLY TO MSG# 509 (NEW ROM?)
  479. Don't use AT&F0, use AT&F2 so you will have error correction.  Otherwise, you
  480. will get many errors at 14400.
  481.  
  482.  
  483. Msg#:  868 *GENERAL*
  484. 06-16-92 09:20:32
  485. From: SYSOP
  486.   To: JIM SANCHEZ
  487. Subj: REPLY TO MSG# 509 (NEW ROM?)
  488. Jim, We will send out the new ROM revision to all registered owners free of
  489. charge in mid-July.  To connect here, set the modem to 9,600 with (AT N S37=9).
  490. Keep the default setting at (AT &F2).  This will work. [Nathan]  Supra
  491. Technical Support
  492.  
  493.  
  494. Msg#:  514 *GENERAL*
  495. 06-06-92 16:54:13
  496. From: ROMAN HEINZ
  497.   To: ALL
  498. Subj: PROBS WITH V.32BIS
  499. Hi Hi
  500.  
  501. I've some problems with my V.32bis .... It doesn't recognize the german busy
  502. tone nor the case of "NO DIALTONE" (Nothing of that ATX4 and ATQ-stuff 
  503. works...) And there are problems in connecting with another Supra or with a US
  504. Robo DualStandart... my registration card should be on the way, please send me
  505. any available  ROM-update!
  506.  
  507.           Roman HEINZ
  508.           Am Steinbruch 5
  509.           6786 Lemberg
  510.  
  511.           GERMANY
  512.  
  513.  
  514.  
  515. (Better release some more relyable stuff in the future)
  516.  
  517. Bye
  518.  
  519. .
  520. ...
  521.  
  522.  
  523. Msg#:  525 *GENERAL*
  524. 06-06-92 21:47:09
  525. From: BRIAN DHATT
  526.   To: JIM EVANS
  527. Subj: 14.4K
  528. You can use 19200.  This will actually connect at 14400.  I have never seen a
  529. comm program that has 14400.  This is becuase all 14400 modems have error
  530. correction and data compression, enabling computer -> modem speeds of over
  531. 19200 bps.  You can keep the setting at 19200 and connect at 2400. This is
  532. becuase 19200 is the modem -> computer speed and the modem -> modem speed can
  533. be anything, because the computer will still receive data at 19200.
  534.  
  535.  
  536. Msg#:  540 *GENERAL*
  537. 06-07-92 14:55:19
  538. From: TOM MEAD
  539.   To: JIM EVANS
  540. Subj: REPLY TO MSG# 94 (14.4K)
  541.         Try using Telix. That will allow you to use any Connection rate you
  542. wan't.
  543.  
  544.  
  545. Msg#:  531 *GENERAL*
  546. 06-07-92 08:10:00
  547. From: TOM MCKEEVER
  548.   To: SYSOP (Rcvd)
  549. Subj: BBS USE
  550. GreetingsHave switched over to SUPRA on my BBS (Spacecon - [407]459-0969], and
  551. need some suggested strings for Front Door 2.02.. I currently get MANY
  552. CONNECT's, followed by NO CARRIER disconnects.. I will also get (ON the Front
  553. Door Screen) "RING" followed by "BUSY".. An IMPOSSIBLEresponse, as I am NOT
  554. dialing out!@
  555. Secondly - I have called Tech support no fewer than 3 Times transcontinental
  556. dayrtime calls to no avail.. If you want sysops to tout or help sell the
  557. product, you SHOULD return calls! - At least COMPUCOM did!!. LASTLY: I fax'ed
  558. Stan some info he wanted.. He was to send me a free copy of the FAX Software..
  559. Has it been released yet?? -- 'nuff fer now.. <G> Take Care - You got a pretty
  560. good product.. keep it up.. send me any ROM upgrades as soon as ready, OK?..
  561. Tom, SysOp SPACECON/Space Station BBS's (407)459-0969  1:374/22....
  562.  
  563. P.S. - Stan was going to send a SUPRA to our ADAnet (Handicapped) Network
  564. headquarters in Birmingham, Al - DO you know if that has taken place yet>>
  565. Ciao.. Tom.. W4NOV.. ADAnet RC
  566.  
  567.  
  568.  
  569. Msg#:  878 *GENERAL*
  570. 06-16-92 09:55:41
  571. From: SYSOP
  572.   To: TOM MCKEEVER (Rcvd)
  573. Subj: REPLY TO MSG# 531 (BBS USE)
  574. Tom, Please leave me a phone number here and I will call you.  Has the busy
  575. problem gone away?   [Nathan] Supra Technical Support
  576.  
  577.  
  578. Msg#: 1003 *GENERAL*
  579. 06-20-92 09:17:37
  580. From: TOM MCKEEVER
  581.   To: SYSOP
  582. Subj: REPLY TO MSG# 878 (BBS USE)
  583. Ok - Phone number: (407)452-2712 - 2-10 PM EDT..  Also getting tremendous
  584. amount of RING - CARRIER DETECTED - CARRIER LOST sequences on the BBS.. The
  585. "Busy" seems to have disappeared..??.. Many times my v32bis callers have that
  586. above problem and have to try calling 3-5 times before connecting.. Have a
  587. feeling it may be related to the LONNNNNG negotiation period.. Tom
  588.  
  589.  
  590.  
  591.  
  592. Msg#: 1155 *GENERAL*
  593. 06-23-92 12:48:38
  594. From: PAUL BUTTERWORTH
  595.   To: TOM MCKEEVER
  596. Subj: REPLY TO MSG# 531 (BBS USE)
  597. OK THE CARRIER DETECT ...CARRIER LOST IS FROM A PROBLEM WITH THE SUPPRA AND
  598. SOMETHING TO DO WITH DTR DROP.....I HAVE BEEN TOLD BY THE TECH. SUPPORT PEOPLE
  599. THAT THE NEW ROM WILL FIX THAT.....THAT WAS ON THE PHONE.... BUT IT SHOULD BE
  600. STATED HERE IF SO SO THAT PEOPLE CAN SAVE TIME AND MONEY FINDING OUT WHAT IS
  601. GOING ON!!!!
  602.  
  603.  
  604. Msg#:  538 *GENERAL*
  605. 06-07-92 14:37:47
  606. From: JON WISWELL
  607.   To: SYSOP (Rcvd)
  608. Subj: OOPS
  609. I just RX'd my v.32 modem (ser#14E013292) without a registration card!! Since I
  610. bought it from the factory (SYSOP special) maybe it's already registared.
  611.  
  612.  
  613. Msg#:  911 *GENERAL*
  614. 06-17-92 09:56:47
  615. From: SYSOP
  616.   To: JON WISWELL
  617. Subj: REPLY TO MSG# 538 (OOPS)
  618. Jon, No! It's not already registered.  Please leave your full name and address
  619. here, requesting a registration card, and I will send one out to you. [Nathan]
  620. Supra Technical Support
  621.  
  622.  
  623. Msg#: 1156 *GENERAL*
  624. 06-23-92 12:50:24
  625. From: PAUL BUTTERWORTH
  626.   To: SYSOP
  627. Subj: REPLY TO MSG# 911 (OOPS)
  628. THAT IS FUNNY SINCE MINE WAS THE SAME WAY!!! REGISTARATION CARD TO..... PAUL
  629. BUTTERWORTH 78 KERR ST. TONAWANDA, NY 14150
  630.  
  631.  
  632. Msg#:  598 *GENERAL*
  633. 06-09-92 08:15:25
  634. From: MIKE PRAGER
  635.   To: SYSOP (Rcvd)
  636. Subj: FAX DIFFICULTIES
  637. I just received the v.32bis FAX-modem. It works fine as a modem, but I am
  638. having trouble faxing reliably (using winfax with the fix from your  bbs). The
  639. modem connects to the other FAX machine, then drops off. The message returned
  640. to the sendfax log in winfax is "Unable to establish connection." Sometimes
  641. turning the modem off and on again before faxing will help this situation.
  642. Therefore I suspect it must be a configuration problem. Can you give me any
  643. advice on this?
  644.   
  645. ...Mike Prager
  646.  
  647.  
  648. Msg#: 1051 *GENERAL*
  649. 06-22-92 05:12:51
  650. From: SYSOP
  651.   To: MIKE PRAGER (Rcvd)
  652. Subj: REPLY TO MSG# 598 (FAX DIFFICULTIES)
  653. Mike, Try setting the FAX speed to 4800.  This solves the problem for most
  654. people.  Also, try using the patch that we have for Winfax, called Suprawin.zip
  655. in the IBM section.  In mid-July, we will be sending out our latest ROM chips,
  656. which should also clear up FAX transmission problems.  Make sure that you send
  657. in your registration card. [Nathan]  Supra Technical Support
  658.  
  659.  
  660. Msg#:  617 *GENERAL*
  661. 06-09-92 14:43:20
  662. From: J9
  663.   To: MARK WHITE (Rcvd)
  664. Subj: SYSOPS PLAN
  665. Mark, I posted a message yesterday asking if there was a wait for the Supra
  666. v.32v.32bis with the sysops plan. Also I'm
  667.  
  668. using a Ventel Plus and cannot connect except for 2400 baud. I would
  669. appreciateyour reply. Thanx again. george Meno
  670.  
  671.  
  672.  
  673. Msg#:  657 *GENERAL*
  674. 06-11-92 01:24:28
  675. From: MARK WHITE
  676.   To: J9
  677. Subj: REPLY TO MSG# 617 (SYSOPS PLAN)
  678. There is about a 4 week wait.  What kind of problem do you have connecting at
  679. greater than 2400.  If it is a v32 modem, are you sure that it has the latest
  680. roms from ventel? (Virtually all v32, and v32bis modems have had one or more
  681. rom upgrades.  This was due to standards being more firmly hammered out when
  682. the v32 and v32bis modems first started shipping.  The standard, as they are
  683. wont to do, had left a number of issues not concretly specified, thus each
  684. manufactore viewed the spec differently than the others.  This is known as
  685. growing pains in the computer industry.)
  686.  
  687. Mark - Supra Tech Support
  688.  
  689.  
  690. Msg#:  754 *GENERAL*
  691. 06-13-92 13:49:29
  692. From: GEORGE MENO
  693.   To: MARK WHITE (Rcvd)
  694. Subj: REPLY TO MSG# 657 (SYSOPS PLAN)
  695. Thanks for the answer. No I have NOT had a Rom upgrade. My modem is about 1
  696. 1/2years old. I'll check with Ventel. It appears that yiu have a wworthwhile
  697. product. I'm having trouble now typing. Again thanks for thr reply. George Meno
  698.  
  699.  
  700. Msg#:  628 *GENERAL*
  701. 06-09-92 21:21:09
  702. From: SEAN PURCELL
  703.   To: ALL
  704. Subj: FAX COMMAND SET
  705. I would like to second the motion that Supra provide at least minimal docs for
  706. thier fax command set.  From my experimentation so far (after optaining the EIA
  707. document they mentioned), I have found that  the commands do NOT match (e.g.,
  708. the Supra accepts AT+FLID="ID" instead of the AT+FLI="ID" mentioned in the
  709. draft spec).  A simple list of supported commands would be helpful for up
  710. programmers...
  711.   --Sean Purcell
  712.  
  713.  
  714. Msg#:  743 *GENERAL*
  715. 06-13-92 11:49:55
  716. From: MARK WHITE
  717.   To: SEAN PURCELL
  718. Subj: REPLY TO MSG# 628 (FAX COMMAND SET)
  719. You are looking at the class 2.0 commands, not the class 2 commands.  Which is
  720. a real problem, class 2 has been in committitee for several years now.  All
  721. modems / software that use class 2 are based apon the early draft (also known
  722. as 2388,2388-A, class 2.0 is known as 2388-B and it has not been accepted yet.
  723. The TR-29 committee just voted on the standard early May, there were 2 NO
  724. ballots, one was not for technical reasons, the other was.  So the TR-29
  725. committee has to consider the technical reasons, it then may make changes,
  726. re-ballot (which is a 3 month period) or I It looks like a min of a few months,
  727. or it could be much longer before the committee will re-ballot.)
  728.  
  729. We have received SOME information from Rockwell, which I have been typing in
  730. over the last week.  Shortly I will be ULing the info, BUT this is by no means
  731. complete docs, nor can we answer questions or give help on the jdocs.
  732.  
  733. Mark - Supra Tech Support
  734.  
  735.  
  736. Msg#:  637 *GENERAL*
  737. 06-10-92 06:34:34
  738. From: JAMES MARPLE
  739.   To: SYSOP (Rcvd)
  740. Subj: BULLETINS/ANNOUNCEMENTS
  741. Looks like you need to update your ascii screen that shows when you plan tio
  742. ship the ROM update and windows software. It wstates that the ROMS will ship in
  743. June, and now you are stating that it will be mid-klate July
  744.  
  745.  
  746.  
  747.  
  748.  
  749. Msg#:  744 *GENERAL*
  750. 06-13-92 11:56:36
  751. From: MARK WHITE
  752.   To: JAMES MARPLE (Rcvd)
  753. Subj: REPLY TO MSG# 637 (BULLETINS/ANNOUNCEMENTS)
  754. We have done exactly what the announcement states, we are shipping ALL fax
  755. packages at this time and we are shipping ROMs to those people who needed the
  756. ROMs for their fax software.  The ROMs that we will have available mid-july
  757. have additional features which are are/have implemented and are now being
  758. tested.
  759.  
  760. Mark - Supra Tech Support
  761.  
  762.  
  763. Msg#:  785 *GENERAL*
  764. 06-14-92 20:44:28
  765. From: JAMES MARPLE
  766.   To: MARK WHITE (Rcvd)
  767. Subj: REPLY TO MSG# 744 (BULLETINS/ANNOUNCEMENTS)
  768. Does this mean that I will get my FAX software "now" as you said it was
  769. shipping now, AND a new ROM that will allow the fax software to work? Or will I
  770. have to wait until July to get the new ROM? OR will I get a new ROM now, and
  771. another one in mmid july? Thanks for your reply!
  772.  
  773.  
  774. Msg#:  923 *GENERAL*
  775. 06-17-92 18:40:00
  776. From: MARK WHITE
  777.   To: JAMES MARPLE (Rcvd)
  778. Subj: REPLY TO MSG# 785 (BULLETINS/ANNOUNCEMENTS)
  779. I see that you have WinFax on backorder.  It was my understanding that we were
  780. shipping them.  I know that some packages were made up.  I will check on it and
  781. find out what the status of that is.
  782.  
  783. Yes, the software packs will include the 1.200C roms.
  784.  
  785. Mark - Supra Tech SUpport
  786.  
  787.  
  788. Msg#: 1087 *GENERAL*
  789. 06-22-92 09:09:11
  790. From: JAMES MARPLE
  791.   To: MARK WHITE (Rcvd)
  792. Subj: REPLY TO MSG# 923 (BULLETINS/ANNOUNCEMENTS)
  793. Thanks for the reply on Winfax and the ROM.
  794.  
  795.  
  796. Msg#:  646 *GENERAL*
  797. 06-10-92 18:54:32
  798. From: KEITH CHUMLEY
  799.   To: ALL
  800. Subj: V32BIS MAKES LINE NOISE!?
  801. Hi! I just received the v32bis faxmodem yesterday and immediately noticed
  802. side-effect. Naturally, my phone wire comes from the wall, thru the supra, and
  803. into my phone. This doesn't cause a problem. However, when I plug the modem
  804. cable from my mac into the supra, the phone line gets extremely noisy! I can
  805. barely hear the person on the other line when they call, unless I disconnect
  806. the modem cable from the supra!  What's the problem?! Am I doing something
  807. wrong? My old modem worked thru these wires fine. I even tried the old modem
  808. cable and it still makes tons of noise just by plugging the modem in! Please,
  809. give me a clue as to the culprit! Has ANYONE else had a similar problem?  BTW,
  810. the modem (obviously) connects fine, even while destroying normal telephone
  811. voice usage! Thanks for any help! a
  812.  
  813.  
  814. Msg#:  662 *GENERAL*
  815. 06-11-92 04:13:34
  816. From: MARC SMITH
  817.   To: SYSOP (Rcvd)
  818. Subj: NEW MSGS
  819. Does your Read New Messages function work on this BBS?  It doesn't appear to
  820. for me.  Also, I left a problem report and request for answer in the Mac forem
  821. a couple of days ago - still no answer.  can't get customer support on the
  822. phone.  What gives?  Did I make a mistake buying Supra?  I bought a Promethieus
  823. Home Ultima and sent it back 'cause I couldn't get customer service/tech
  824. support to respond.  A couple more days and I'll send this one back.  It does
  825. me no good to have a modem and not be able to get through to tech support on
  826. the phone no matter what the warranty.  You can call me next week Mon thru
  827. Thurs @ 513-498-6345 7AM to 4PM EDT.  I would appreciate the courtesy of a
  828. reply by telephone (a respone here wouldn't hurt either...)
  829.  
  830.  
  831. Msg#: 1077 *GENERAL*
  832. 06-22-92 08:18:48
  833. From: SYSOP
  834.   To: MARC SMITH (Rcvd)
  835. Subj: REPLY TO MSG# 662 (NEW MSGS)
  836. Marc, Sorry for the delay in responding to your messages.  I will give you a
  837. call by voice. [Nathan]  Supra Techncial Support
  838.  
  839.  
  840. Msg#: 1148 *GENERAL*
  841. 06-23-92 07:13:07
  842. From: MARC SMITH
  843.   To: SYSOP
  844. Subj: REPLY TO MSG# 1077 (NEW MSGS)
  845. Hold off for a while.  I am looking at a few thiongs so that I can give you a
  846. reasonable amount of information.  I'm using my modem at work on a phone system
  847. by ROLM CBX.  I took it home and found the modem's busy response worked fine on
  848. my home line - but it does not on the system here.  But beyond that some
  849. strange things are happening which I cannot Account for.  By the way, my
  850. background is military electronics (high reliability aerospace) so I do have a
  851. reasonable technical background.  As I get some usable info I'll get back with
  852. you.
  853. . I am seeing some strange stuff, though.  One BBS I call I connect with fine
  854. here, but on my home computer I get gibberish all over the screen.
  855. . Even more perplexing - which maybe you can give me some guideance on is this
  856. - what's the scoop with Mac Serial Ports?  And - I call one Mac BBS and can
  857. download seeing 17XX - quite fast.  But when I try to upload I get almost
  858. continuous ZRPOS (CRC-32) errors.  Mac LC II, Z-term, &F1, Z-modem, no TX or RX
  859. error from modem - so it must be between my computer and my modem - but why can
  860. I download without a hitch but have so many problems uploading. - Any ideas?
  861. Even lowing to 9600 I get the same multiple ZRPOS errors.
  862. . Having spent some time with it now, it is a nice modem.  FAX is excellent (I
  863. did have an old Abaton 24/96).  I can connect here fine at 19.2/14.4.
  864.  
  865.  
  866. Msg#:  673 *GENERAL*
  867. 06-11-92 16:34:54
  868. From: ERNIE BLANCHARD
  869.   To: MARK WHITE (Rcvd)
  870. Subj: SUPRA V.32 MODEM
  871. I purchased three V.32 bis modems. They were some of the first modems shipped
  872. and are not always accepting communications from my communications software. It
  873. is necessary for me to turn the modem off and back on to get it back into
  874. service. I run a BBS and have had to take the modems off line because it has
  875. become an embarasment (the large amount of downtime because of the problems) .
  876. The message on the front of my board is not doing your modem's reputation a lot
  877. of good. 
  878.         I personally know that your company suports it's products but its hard
  879. to convince the people calling that could not get through. your tech rep sent
  880. me one set of "D" roams which is a temporary patch for the one and solves the
  881. major problem. That modem still does not connect every time thus causing users
  882. to call several times just to connect. Please send me the latest roams for all
  883. three modems as soon as you possibly can.
  884.         The modem serial numbers are 14E001402  14E001404 and 14E001405   Can
  885. you call me at 310) 946-7212 and let me know how soon I can get help?
  886.                                         Thanks Ernie Blanchard
  887.  
  888.  
  889. Msg#:  718 *GENERAL*
  890. 06-12-92 23:34:23
  891. From: MICHAEL DONOHUE
  892.   To: SYSOP (Rcvd)
  893. Subj: SUPRAFAX V.32BIS
  894. Hi:
  895.   Just received my new modem and out of the box with the AT &F2 &Q9 the unit
  896. works perfectly, though I haven't tried the Fax as of yet. Great peice of kit
  897. so far. Can you tell me though sometimes after the dialling sequence is
  898. completed I hear this clicking sound until the D/T answers, and then it stops.
  899. (I don't use Pulse dialling). Also the odd time the Modem has a hard time to
  900. distinguish between the European Busy signal, is there a S register to fix this
  901. minor inconvience. Other than that great kit. Put me in for the ROM update,
  902. Registration Card is in the mail.
  903.         
  904. Ser #14E007010 Michael J. Donohue Jagerspad 69 Landgraaf 6374 CX The
  905. Netherlands
  906.  
  907.  
  908. Msg#:  746 *GENERAL*
  909. 06-13-92 12:06:08
  910. From: MARK WHITE
  911.   To: MICHAEL DONOHUE (Rcvd)
  912. Subj: REPLY TO MSG# 718 (SUPRAFAX V.32BIS)
  913. In the new ROM we have made a slight change in its detection of busy.  THis may
  914. or may not help you in Europe.
  915.  
  916. Mark - Supra Tech Support
  917.  
  918.  
  919. Msg#:  829 *GENERAL*
  920. 06-15-92 11:36:19
  921. From: URBAN LARSSON
  922.   To: NATHAN
  923. Subj: ROM UPGRADE
  924. No need to send the ROM upgrade to me around half the globe. Post them as files
  925. on this BBS so that I can download them. As I understand you already have ROM's
  926. for fixing the FAX bug, if so put them up in the file areas please.
  927.  
  928.                            Regards   Urban Larsson, Sweden
  929.  
  930.  
  931.  
  932. Msg#:  840 *GENERAL*
  933. 06-15-92 19:50:03
  934. From: GARY MEADE
  935.   To: SYSOP (Rcvd)
  936. Subj: SYSOP DEAL
  937. I placed an order for you Supra 14,4 .32 bis about a month ag or so.  I did get
  938. the fax software that I ordered seperately but haven't heard anything on the
  939. modem.  I hear you guys are really swamped but wondered if I might find out
  940. something.  My reason for inquiring is  I saw the modem (Supra)  offered by a
  941. place out of Wisconsin for about $75 more that your sysop deal With the mail I
  942. have been downloading I can make that back in a month. I understand your people
  943. call the BBS, to ensure its existence, and I haven't seen  any new users with
  944. Oregon adress so was concerned.  I don't want to slow anything up but would
  945. appreciate anything you can do to let me know about how long it will take,  The
  946. wife just told me she thinks it was the second week of may when I faxed in the
  947. order.  Thaynk you   Gary Meade - Sysop Tiger Run BBS.   PS  This full screen
  948. editor sucks. :}
  949.  
  950.  
  951.  
  952. Msg#: 1171 *GENERAL*
  953. 06-24-92 09:40:03
  954. From: SYSOP
  955.   To: GARY MEADE
  956. Subj: REPLY TO MSG# 840 (SYSOP DEAL)
  957. Gary, We sent your modem on the 16th UPS Ground.  You will probably use it to
  958. read this message.  If you have any more questions, please let me know. 
  959. [Nathan]  Supra Tehcnical support
  960.  
  961.  
  962. Msg#:  845 *GENERAL*
  963. 06-15-92 23:38:21
  964. From: RICHARD LI
  965.   To: SYSOP (Rcvd)
  966. Subj: LINK MAIL WITH HONG KONG BBS
  967. Hello Sysop,
  968.  
  969. I am a Sysop of a BBS in Hong Kong, I want to ask that if I can linked the mail
  970. about Supramodem with your BBS, so that we can exchange the information about
  971. the reaction of the Supra users in both Hong Kong and USA more effectively,
  972. since there is no need for the Supra users in Hong Kong to dial IDD and log in
  973. your BBS directly which cost a lot.
  974.  
  975. If we can linked up the mails, please inform me which program you used and how 
  976. can I download and upload mail packets to you or any other ways that we can do 
  977. with this.
  978.  
  979. Thank you very much
  980.  
  981. Richard Li A Supramodem lover
  982.  
  983.  
  984.  
  985. Msg#: 1172 *GENERAL*
  986. 06-24-92 09:44:03
  987. From: SYSOP
  988.   To: RICHARD LI
  989. Subj: REPLY TO MSG# 845 (LINK MAIL WITH HONG KONG BBS)
  990. Richard, We are using TBBS software on this board.  The best way to exchange
  991. information is to DL all the messages from this board, and put them up in a
  992. file(s) on your system. You can also call CompuServe and GEnie to see what
  993. people there have to say about the Supra modems.  (The numbers are in the Info
  994. about Supra, on this board). If you have any more questions, please let me
  995. know. [Nathan]  Supra Technical Support
  996.  
  997.  
  998. Msg#:  846 *GENERAL*
  999. 06-16-92 00:08:00
  1000. From: KENNETH DUKE
  1001.   To: ALL
  1002. Subj: FRONTDOOR
  1003. I was wondering if anyone out there is running their Supra v32bis modem with
  1004. frontdoor v2.02NC...
  1005.  
  1006. If someone is, and has everything running just fine, could you please upload
  1007. your init strings here along with how you have FD setup.
  1008.  
  1009. Thanks!
  1010.  
  1011.  
  1012. Msg#:  853 *GENERAL*
  1013. 06-16-92 06:12:03
  1014. From: JAMES MARPLE
  1015.   To: ALL
  1016. Subj: VFAST/US ROBOTICS
  1017. Message #1051 - DFW_SALE 
  1018.    Date: 06-12-92 20:52
  1019.    From: Jean Hart
  1020.      To: Dean Lachan Subject:: Usr hst
  1021. -------------------------------------------------------------------------------
  1022. @EID:2cd4 18cf8f55 4d453220
  1023. * Forwarded by Jean Hart (ME2 1:130/21)
  1024. * Area : NET130
  1025. * From : Rod Marsh                           12-Jun-92 20:52:00
  1026. * To   : All                                 12-Jun-92 23:31:12
  1027. * Subj.: Usr hst
  1028.  
  1029. USR has as of June 8th, 1992 announced their upgrade policy to the V.FAST  
  1030. standard as is currently under evaluation by the CCITT for adoption sometime in
  1031. the future.
  1032.  
  1033. These models of USR High Speeds modems will be upgraded to V.Fast after formal
  1034. announcement of the Standard by the Committee.
  1035.    Courier V.32bis            Internal and external  57600 bps versions only
  1036.    Courier HST Dual Standard  Internal and external    "
  1037.    Courier V.32bis Fax/Mdm    Internal and external
  1038.    Courier HST DS Fax/Mdm     Internal and external
  1039.    Shared Access Modem Sharing Kit single and dual port
  1040.  
  1041. The annoucement is addressed from Theresa mcGeary at 11:44 AM 6/8/92
  1042.  
  1043. Other highlights:
  1044.  
  1045. The proposed standard is for a carrier rate of 28.8KPBS Field upgrade kits will
  1046. be priced at $295 Expected arrival date is January 1994 The Upgrade can be  
  1047. completed by the end user at his worksite!  No need for a depot upgrade.
  1048.  
  1049. The Sportster and Worldport V.32 modems are NOT included in this upgrade.
  1050.  
  1051. The new modems now have remote-programmability, Fax and Fax/modem software  
  1052. included.  All this is still the same old price as before.
  1053.  
  1054. Better yet, the new V.Small series of Modems (V.32bis) and the Shared modem  
  1055. will be USER upgradable to V.FAST in January 94, for less than $300.  That is  
  1056. immediately after the formal adoption of the V.Fast spec, and certainly not  
  1057. before the CCITT.  So if the CCITT delays, the V.Fast upgrade will be delayed.
  1058.  
  1059. The new V.Small series has the modem DSP and supervisor sitting on a daughter  
  1060. board that is easily removed, and replaced by the new board by the owner/user  
  1061. of the modem.  This upgrade will not require a return to USR of the entire  
  1062. modem.
  1063.  
  1064.  
  1065.    Gees if this happens v.32bis only modems will just be another SLOW modem.
  1066.  
  1067.  Just passing information along. Do with it as you will..... But you should  
  1068. very definitely notice that the upgrade is done on the user end. NO NEED to  
  1069. send the HST back to USR....
  1070.  
  1071. --- InterPCB 1.50
  1072.  * Origin: Connect PC / PCBoard * 817-656-7620 (1:130/70)
  1073.  
  1074.  
  1075. Msg#: 1023 *GENERAL*
  1076. 06-20-92 21:33:18
  1077. From: MARK WHITE
  1078.   To: JAMES MARPLE (Rcvd)
  1079. Subj: REPLY TO MSG# 853 (VFAST/US ROBOTICS)
  1080. Several things to remember...
  1081.  
  1082. 1.  V.fast is still in committee, only after ALL members approve the
  1083. standard will it be approved.  This can be a short or sometimes a very     long
  1084. process.  
  1085.  
  1086. 2.  All new standards have a period of time during which they are rung out
  1087. by manufactores.  Even though there is a standard, each manufacture     will
  1088. interrupt it slightly differently.  There is a period of time     while
  1089. everyone agrees on what the standard actually means. 
  1090.  
  1091. 3.  While the standard proposes a 28K baud signalling rate it has NOT been
  1092. proven how well this will work in the real world.  It is acknowledged     by
  1093. the CCITT committite that it will ONLY WORK under ideal conditions.
  1094.  
  1095. 4.  V.Fast will have a better ability than v32bis does in determining what
  1096. line speed a particular connection can work at.
  1097.  
  1098. 5.  With ISDN slowly making inroads, and depending on how long it takes     for
  1099. V.Fast to be approved/wrung out, V.Fast may or may not become a     major
  1100. standard.
  1101.  
  1102. 6.  There is a major battle between modem manufactures (several of which
  1103. are on the v.fast committe) over the standard.  The feuding is over     the
  1104. ability to make the standard workk on the processors used in     current
  1105. v32/v32 bis modems.  Depending on the DSP / processor used,     v.Fast maybe
  1106. simply a ROM or ROM/DSP/Processor upgrade or it
  1107.     may require substantial improvements in the DSP/Processor.
  1108.  
  1109. 7.  New standards are always on the horizions in the computer world.  The
  1110. big question, do you wait for it, buy now, buy what maybe able to be
  1111. upgraded in the future (generally more $$ now, with the upgrade     possibly
  1112. more or the same $ to buy a new product that supports the new     standard!)
  1113. That question is one that the individial person has to     answer for themself.
  1114.  
  1115. Mark - Supra Tech Support
  1116.  
  1117.  
  1118. Msg#:  905 *GENERAL*
  1119. 06-17-92 09:26:17
  1120. From: FLORO CRISOSTOMO
  1121.   To: SYSOP
  1122. Subj: NEW SUPRA MODEM/FAX
  1123. Hi.  From discussions in CIS, I finally bought your top-of-the-line fax/modem
  1124. v.32bis.  Just got it 20 minutes ago.  Setup it up in five minutes.  Looked for
  1125. you BBS number in your manual and here I am. The display shows 120, I guess
  1126. because the lines here are bad due to the heavy rains.
  1127.    So far so good.  Downloaded pertinent messages to read offline and some
  1128. informative files.
  1129.    I am happy so far!
  1130.  
  1131.    Floro   :)
  1132.  
  1133.  
  1134. Msg#:  933 *GENERAL*
  1135. 06-18-92 02:19:02
  1136. From: JEAN PASTOR
  1137.   To: MARK WHITE (Rcvd)
  1138. Subj: V23 PROTOCOL
  1139. I am sysop of "The Parisian Medical" (France) 33-1-40250585 My fido address is
  1140. 2:320/3
  1141.  
  1142. I have purchased TWO SFM V32 bis, one via CompuClassic (we named it A), the
  1143. other from you , with sysop deal (named B).
  1144.  
  1145. For the both, I have made the same set up: AT &F2 S11=70 &W2 &Y
  1146.  
  1147. They both work well, except for V23. (7-E-1) The "A" one works well with V23 
  1148. The "B" dial, then 2 seconds after the carrier modulation, it hangs up with "no
  1149. carrier".If I set N0, then there is a long carrier without modulation, and I
  1150. must hang up.
  1151.  
  1152. Here is the profile of "A": ACTIVE PROFILE: B1 E1 L2 M1 N1 Q0 T V1 W2 X4 Y0 &C1
  1153. &D2 &G0 &J0 &K3 &Q5 &R0 &S0 &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010
  1154. S05:008 S06:002 S07:050 S08:002 S09:006 S10:014 S11:070 S12:050 S18:000 S25:005
  1155. S26:001 S36:007 S37:000 S38:020 S44:003 S46:138 S48:007 S49:008 S50:255
  1156.  
  1157. And the profile of "B": ACTIVE PROFILE: B1 E1 L2 M1 N1 Q0 T V1 W2 X4 Y0 %G1 &C1
  1158. &D2 &G0 &J0 &K3 &Q5 &R0 &S0 &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010
  1159. S05:008 S06:002 S07:050 S08:002 S09:006 S10:014 S11:070 S12:050 S18:000 S25:005
  1160. S26:001 S36:007 S37:000 S38:020 S44:003 S46:138 S48:007 S49:008 S50:255
  1161.  
  1162. The only difference is the %G1..and I don't know what is it (not in manual)
  1163.  
  1164. Here the identification for "A": ati3 V1.000-E TR14-Jxxx-001 003 Registration
  1165. #:14E004209
  1166.  
  1167. And for "B": ati3 V1.200-C TR14-Jxxx-001 032 Registration #:14E011689
  1168.  
  1169. I have sent 2 fax to your company, without answer. Except this BIG problem for
  1170. me (In France, most of medical databases are with the V23 protocol), all is ok:
  1171. I use Wildcat, Qmodem for modem part, and QL2FAX or WINFAX for the fax part,
  1172. without problem and for the BOTH modem.
  1173.  
  1174. Do I need the new ROM ? Or it is just a configuration problem ?
  1175.  
  1176. Would you please help me. Thank you for a quick answer.
  1177.  
  1178.  
  1179. Msg#: 1016 *GENERAL*
  1180. 06-20-92 20:25:23
  1181. From: MARK WHITE
  1182.   To: JEAN PASTOR (Rcvd)
  1183. Subj: REPLY TO MSG# 933 (V23 PROTOCOL)
  1184. The problem is that at this time, Rockwell does not officially support v23 in
  1185. the v32/bis chipset.  It does so happen to sort of work, but not fully.
  1186. Sometime in the future Rockwell will have a full implementation of v23, but at
  1187. this time, we do not have an ETA for this.
  1188.  
  1189. Mark - Supra TEch Support
  1190.  
  1191.  
  1192. Msg#:  965 *GENERAL*
  1193. 06-19-92 07:50:11
  1194. From: PETER
  1195.   To: ALL
  1196. Subj: NUMBERS
  1197. Hi to all ... I'm inm search for some chat-bbs's with multi-line support .. 
  1198. Could anybody leave me some numbers ? l8ter ... Peter
  1199.  
  1200.  
  1201. Msg#:  968 *GENERAL*
  1202. 06-19-92 09:02:54
  1203. From: ANDY LEWIS
  1204.   To: MARK WHITE (Rcvd)
  1205. Subj: NEED TECHNICAL SUPPORT
  1206. Dear Mark, I am in technical support for Group Technologies, Inc., publishers 
  1207. of Aspects real-time conferencing software for Macintosh. One of our large
  1208. accounts is attempting to use Aspects with a Supra V.32 Fax Modem and has not
  1209. beeen successful. I would like to work with a member of your tech. support
  1210. group to determine the proper setup string for this modem to get it working
  1211. with Aspects. Please have some one call me to discuss how we can make this
  1212. happen. Group Technologies phone is 703-528-1555.   I have attempted to get
  1213. through to you by phone and fax all week without any luck.  I realize you folks
  1214. are very busy and appreciate the difficulty of you job; however, it would be
  1215. nice to get some kind or response  indicating that you have received my message
  1216. and information on when I can expect to get help. Thanks in advance for your
  1217. help, Andy Lewis
  1218.  
  1219.  
  1220. Msg#: 1020 *GENERAL*
  1221. 06-20-92 20:31:54
  1222. From: MARK WHITE
  1223.   To: ANDY LEWIS (Rcvd)
  1224. Subj: REPLY TO MSG# 968 (NEED TECHNICAL SUPPORT)
  1225. Ok, I will give you a call early next week.
  1226.  
  1227.  
  1228. Msg#: 1183 *GENERAL*
  1229. 06-24-92 14:36:32
  1230. From: ANDY LEWIS
  1231.   To: MARK WHITE (Rcvd)
  1232. Subj: REPLY TO MSG# 1020 (NEED TECHNICAL SUPPORT)
  1233. Mark, Thanks for you reply.  I will be looking forward to hearing from you
  1234. early next week.  I am sending a copy of our product, Aspects, to you to help 
  1235. us solve the problem. Regards,
  1236.  
  1237.  
  1238. Msg#:  986 *GENERAL*
  1239. 06-19-92 22:59:44
  1240. From: BOB KIFFERLY
  1241.   To: ALL
  1242. Subj: LINE NOISE
  1243.  The Line noise has been really bad here the past few nights. Whew.
  1244.  Squirrels dancing on the wires perhaps?
  1245. /s
  1246.  
  1247.  
  1248. Msg#: 1011 *GENERAL*
  1249. 06-20-92 15:34:44
  1250. From: JOE QUILICI
  1251.   To: JAMES MARPLE (Rcvd)
  1252. Subj: DROPPED CARRIER
  1253. I agree with you on the U.S. Robotics note, at least they have a guaranteed
  1254. upgrade to v.34 (which is in the approval stage by the CCITT llows line rates
  1255. o28.4K baud without compression).  I cannot even connect to this BBS at a full
  1256. 14.4K, I need to manually drop my baud rate to 9600 or lower or I get a dropped
  1257. carrier.  I've asked numerous questions on here before, each only received a
  1258. brief answer, which didn't answermy question or no reply at all. 
  1259.  
  1260.  
  1261. Msg#: 1014 *GENERAL*
  1262. 06-20-92 16:22:00
  1263. From: JEFF LINDSTROM
  1264.   To: ALL
  1265. Subj: INTERNATIONAL FAX PROBLEM
  1266.   I have been unable to connect with a FAX in Australia.  I have been able to
  1267. receive a file from a modem over there (albeit quite slowly because of errors).
  1268.  
  1269.   I am using GPFax on the Amiga with my Supra V.32bis FAXmodem.
  1270.   I have modified the Init string to wait longer for Data Carrier (up to S7=120
  1271. seconds) and inserted the N command and programmed the speed for 4800 and 9600
  1272. (S37=8 & 9).
  1273.   Just to be on the safe side, I would Quit the entire program, start it,
  1274. verify the Init string, and then try to send the FAX.  I also preset registers
  1275. with NComm before starting GPFax.
  1276.   I don't know if these commands would even be accepted, though, as the M2
  1277. command (Speaker always ON) is overridden by the Options settings for the
  1278. modem, so I don't know which other settings would be controlled by GPFax after
  1279. the Init string is sent.
  1280.   The closest I have gotten when dialing is the Receiver ID number (not simply
  1281. a reflection of the number I dialed as it does not have the International
  1282. Access prefix, 011).  But the Speed setting never gets set and eventually the
  1283. Time Out hangs up.
  1284.  
  1285.  
  1286. Msg#: 1032 *GENERAL*
  1287. 06-21-92 00:28:04
  1288. From: GLENN NAFIN
  1289.   To: SYSOP
  1290. Subj: ROM UPGREAD
  1291.   Well i hope i a on the list for the rom upgread,the 14,4 that i have has a
  1292. number of #900001 so i think it might be one of the first? P.S can you check to
  1293. see if you got my warrenty card?
  1294.  
  1295.  
  1296. Msg#: 1036 *GENERAL*
  1297. 06-21-92 10:51:32
  1298. From: JIM OTT
  1299.   To: SYSOP
  1300. Subj: V.32BIS
  1301. Hello, We are a dealer and just recieved our first shipment of V.32bis units, 
  1302. they seem to work fine.  However, in reading your BBS there is talk of new ROMS
  1303. (July) and problems with Winfax.  Winfax seems to work fine on the units we
  1304. recieved.  Do thse have ROMS that fixed that problem, are there still new ROMS
  1305. coming out to fix other problems?  If so what are those problems.  Also, I have
  1306. a customer trying to MNP 10 working and says it doesn't work.  Is my customer
  1307. doing something wrong or it there a bug in MNP 10.  If there are new ROMS
  1308. coming out in July will you ship those to us so that we can upgrade units on
  1309. the shelf.  One last question, is the Windows fax software you are offering the
  1310. full Winfax pro package. If you could have someone get back to me on these
  1311. issues it would be  helpfull. Thx,  Jim Enhanced Technologies (714) 255-8349
  1312.  
  1313.  
  1314. Msg#: 1088 *GENERAL*
  1315. 06-22-92 09:10:42
  1316. From: JAMES MARPLE
  1317.   To: JOE QUILICI
  1318. Subj: 14.4 CONNECTS
  1319. I have no trouble at all with 14.4 connects here. I get 1600-1700 cps transfers
  1320. as well.
  1321.  
  1322.  
  1323.  
  1324. Msg#: 1166 *GENERAL*
  1325. 06-23-92 22:39:41
  1326. From: ANDREW ABERNATHY
  1327.   To: ALL
  1328. Subj: UUCP
  1329.   I just received my v.32bis about a week ago.  (love it!)  I'm using it mainly
  1330. for a uucp connection.  I'm hoping someone can help me- my upstream site has
  1331. three lines, a 2400 and two v.32bis (not Supra).  I'm fine on the 2400, and the
  1332. login goes fine on the v.32bis lines, but gets stuck with an "imsg looking for
  1333. SYNC< " message, then times out after a minute and drops the line.  I think
  1334. this is really a uucp problem, but hoping someone here has some suggestions.
  1335.  
  1336. To the sysop:  I've got the bbs number, the support number, the compuserve
  1337. address, applelink, BIX, GEnie, AOL...but no Internet address!  This would help
  1338. me greatly, even if it's gatewayed through AOL, I just need the address.
  1339. Thanks.
  1340.  
  1341. (p.s.  I'm using this modem on a NeXT...any other NeXT users out there using
  1342. this nice new modem?  I've got a driver that does sendfax, BTW, but hogs the
  1343. serial port, so you have to disable it to use modem for anything else.)
  1344.  
  1345. andrew_abernathy@wire.gwinnett.com
  1346.  
  1347.  
  1348. Msg#: 1188 *GENERAL*
  1349. 06-24-92 17:17:02
  1350. From: MIKE COOMBS
  1351.   To: SYSOP
  1352. Subj: DEALER INFO
  1353. HI THERE. I AM A RETAIL DEALER IN THE SEATTLE AREA. I HAVE CURRENTLY SOLD 1 OF
  1354. YOUR 14.4/14.4 FAX/MODEMS AND THE USER ABSOLUTRLY LOVES IT. AS DO I. I TESTED
  1355. BEFORE SELLING. A WONDERFUL PIECE OF WORK. I WOULD LIKE TO BE ABLE TO DIRECTLY
  1356. DEAL WITH YOU, AS TO GET BETTER PRICING, ETC. THE FOLLOWING IS INFO ABOUT ME
  1357. AND MY COMPANY.
  1358.  
  1359. EMERALD CITY DATA SYSTEMS P.O. BOX 33061 <-MAILING ADDRESS 2332 N. 136TH.
  1360. <-SHIPPING ADDRESS SEATTLE, WA. 98133 (206)367-2393
  1361.  
  1362. THE OWNERS ARE: MIKE COOMBS (SELF) AND TED COOMBS (MY FATHER)
  1363.  
  1364. IF THERE ARE ANY OTHER QUESTIONS OR INFO YOU WOULD LIKE, FEEL FREE TO CALL ANY
  1365. TIME !!! THANKS. I LOOK FORWARD TO DEALING WITH YOU!
  1366.  
  1367.                                         MIKE COOMBS
  1368.                                         EMERALD CITY DATA SYSTEMS
  1369.  
  1370.  
  1371. Msg#: 1189 *GENERAL*
  1372. 06-24-92 17:29:53
  1373. From: LOUIS DIMARCO
  1374.   To: SYSOP
  1375. Subj: LIST ADDITION
  1376. Please make sure my name is added to the list for the new rom.  I have sent in
  1377. my registration card.
  1378.             Louis DiMarco
  1379.             6123 Westbrooke Drive
  1380.             West Bloomfield, MI 48322 Thanks you.
  1381.  
  1382.  
  1383. Msg#: 1218 *GENERAL*
  1384. 06-25-92 06:36:45
  1385. From: JIM SOUZA
  1386.   To: ALL
  1387. Subj: TELEMATE 3.01
  1388.  Has anyone the strings for Telemate with the Supra 14.4 fax modem?
  1389.  
  1390.  
  1391. Msg#: 1274 *GENERAL*
  1392. 06-25-92 22:29:45
  1393. From: BOB KIFFERLY
  1394.   To: ALL
  1395. Subj: DATA BASE
  1396.  Hey. Good job on the registration database.
  1397.  
  1398.  
  1399. Msg#: 1278 *GENERAL*
  1400. 06-26-92 03:44:56
  1401. From: MATTIAS LARSSON
  1402.   To: SYSOP
  1403. Subj: ROM UPGRADE AND V.FAST
  1404. Hi!
  1405.  
  1406. I've bought a Supra FAXmodem V.32bis, and it works (almost) great! But I've got
  1407. problems connecting to older HST/DS modems, have I setup my modem incorrectly
  1408. or is there some kind of incompatibility between them? Is there any possibilty
  1409. to detect wheter an incoming call is a FAX call or a data call?
  1410.  
  1411. I have read that USR offers V.fast upgrades for $295 to their users. Will Supra
  1412. also offer upgrades for their V.32bis users, or do I have to buy me a new
  1413. modem?ec[| 
  1414.  
  1415. I've sent in my warranty registration card, but top be on the safe side i'll
  1416. give you my adress here also, so you can send my the latest ROM upgrades..
  1417.  
  1418. Mattias Larsson Blaklintsvagen 20 S-445 57  SURTE Scandinavia, Sweden
  1419.  
  1420.  
  1421. Msg#: 1318 *GENERAL*
  1422. 06-27-92 00:41:31
  1423. From: MARK WHITE
  1424.   To: MATTIAS LARSSON
  1425. Subj: REPLY TO MSG# 1278 (ROM UPGRADE AND V.FAST)
  1426. We do not have access to the v.fast specs yet, but our discussions with people
  1427. who are on the committee would indicate that it is a little early to be
  1428. advertising v.fast.
  1429.  
  1430. 1.  Cost If you compare the retail price of the DS (I don't know what the
  1431. retail cost is on the other 2 models that they will be able to do this with) is
  1432. $1195 + $295 for the v.fast upgrade means you get this for $1500 retail.  For
  1433. $1500, I could buy a couple of Supra v32bises, and if we came out with a new
  1434. modem for v.fast buy that and have saved a nice chunk of change, or 
  1435.  
  1436. 2. Can USR run v.fast reliably? Depending on what v.fast winds up being, it is
  1437. very possible that other componets in their design, other then the DSP and
  1438. Supervisor, will not be able to handle v.fast.
  1439.  
  1440. 3.  When will v.fast be adopted? The standard has not been accepted,it has not
  1441. been proven how reliablly it will actually work in the real world and there are
  1442. several proposals of what v.fast should be.  When there are several different
  1443. competing proposals, it can take a long time to develope the standard. (Look at
  1444. Class 2, it has been argued about for more than 5 years, and it still has not
  1445. been adopted.)  Whereas v32bis was more of a outgrowth of v32 with some added
  1446. features.  I very much doubt that if a phone line can not handle v32bis, it
  1447. will not work better with v32bis.  Which leads me to....
  1448.  
  1449. 4.  Other competing technologies. USR says a min of 1.5 yrs from now they will
  1450. have it available.  ISDN may finally get its act together by that time.  The
  1451. phone companies have been bickering amoungst themselves about ISDN.  It is very
  1452. likely that the flood of v32bis modems over the next 2 years will drive them to
  1453. put the pickering aside and as Nikie says "Just Do It".  Why?  Those phone
  1454. systems that can not handle 14.4Kb will be forced to more quickly update their
  1455. systems, which means digital.  As the phone companies push more and more of
  1456. their analog lines to digital, at some point they will want to / need to hook
  1457. up digitally to the house.  Also the phone companies want to sell you data
  1458. services, which again means putting digital lines into the home.  (They have
  1459. the cable people pursuing similar ventures, so the ol competition rears its
  1460. head.)  It is very possible that v32bis will be the final major analog modem
  1461. standard.  Only time will tell.
  1462.  
  1463. Mark - Supra Tech Support
  1464.  
  1465.  
  1466. Msg#: 1317 *GENERAL*
  1467. 06-26-92 23:56:38
  1468. From: JIM OTT
  1469.   To: SYSOP
  1470. Subj: MSG 1036
  1471. I was just checking the status of my message left last week. MSG # 1036, I have
  1472. not yet had a response to it. Thx, Jim
  1473.  
  1474. No more messages in section *GENERAL*
  1475.  
  1476. Reading Message Board *MODEM*
  1477. Section has 338 Msgs, #278 to 1322 
  1478.  
  1479. Starting number, <CR>=First: 
  1480.  
  1481.  
  1482. Msg#:  278 *MODEM*
  1483. 05-28-92 02:32:33
  1484. From: MICHAEL WALTERS
  1485.   To: MARK WHITE (Rcvd)
  1486. Subj: SUPRA FAX COMMAND SET
  1487. MW> From your message it appears that you are MW> not trying to write fax
  1488. software.
  1489.  
  1490.     I may do that since I do program regularly in Lattice (SAS) 'C', Assembly 
  1491. and Modula-2.
  1492.  
  1493. MW> If this is the case, the class 1 and class 2 MW> commands are almost
  1494. useless to you.
  1495.  
  1496.     As it happens, the only FAX software I've been able to obtain requires 
  1497. those commands to be entered into a config file that is used to set up for send
  1498. or receive. Such as:
  1499. -------------------------
  1500. RSetup ATM2L2S7=255S0=1+FCLASS=2+FCR=1+FAA=1+FDCC=1,1,0,0
  1501. -------------------------
  1502.     As it is I had to get those commands from someone in the netherlands who 
  1503. got them from Rockwell.
  1504.     In any case I don't see how these commands are fundamentally different from
  1505. the usual Hayes AT commands that are also normally handled by software but
  1506. which are also required to configure said software.
  1507.  
  1508. MW> This is NOT ascii data, but rather a complex bit image.
  1509.  
  1510.     I know that. I've been a certified electronic technician and engineering 
  1511. associate for over 15 years. Your not dealing with a chimp here. (no offense)
  1512.  
  1513. MW> All together, the class 1, class 2, t.4 and t.30 standards are covered MW>
  1514. in about 300 pages of VERY technical writing.
  1515.  
  1516.     I'm not talking about the complete specs. Just a list of command and 
  1517. parameters as with the AT commands. I don't need (though I do have) the entire 
  1518. spec on MNP to use the AT commands that deal with it do I?
  1519.  
  1520. MW> To write fax software you need ALL of this information.
  1521.  
  1522.     And to use FAX software you need a minimum of information, somthing like
  1523. the following:
  1524. -----------------------------
  1525. AT+FDCC=1,5,0,2,x,x,x,x 
  1526.                    |
  1527.         ^ ^ ^ ^    +------- ???
  1528.         | | | +- Page Length: 0=A4(297mm) 1=B4(364mm) 2=unlimited
  1529.         | | +--- Page Width : 0=1728 Pixels in 215mm (Current AmigaFax Limit)
  1530.         | +----- Bit Rate   : 0=2400 1=4800 2=7200 3=9600 4=12000 5=14400
  1531.         +------- Vert. Res. : 0=Normal(98 lpi) 1=Fine(196 lpi)
  1532.  
  1533. -----------------------------
  1534.     I still don't know what the last four parameters are but until I got the
  1535. first four I was unable to connect with any fax machine I called because the
  1536. software as it came was set for 14400 baud and 1.) I have the v.32 modem and
  1537. 2.) One modem I was calling was an older 4800 baud. And the Supra FAX modem
  1538. would NOT fallback! Sounds like a bug to me.
  1539.     Also, if I don't know what the result codes mean how am I to determine what
  1540. the cause of a failure is?
  1541.     All this could easily fit on a page or two in the manual so their really is
  1542. no excuse.
  1543.  
  1544.  
  1545.  
  1546. Msg#:  343 *MODEM*
  1547. 05-31-92 23:02:38
  1548. From: MARK WHITE
  1549.   To: MICHAEL WALTERS
  1550. Subj: REPLY TO MSG# 278 (SUPRA FAX COMMAND SET)
  1551. You are using the ONLY package I have run accross on the Mac, PC, Unix, Amiga,
  1552. and ST in which you had to enter a config string for setting up the fax
  1553. software.  (Over 20 fax packages.)  It is the software author who needs to give
  1554. you the correct string.  The correct string IS VERY software dependant.  Also,
  1555. while there are established standards (class 1 or 2), especially class 2 is
  1556. still in a state of flux.  Any docs we put in the manual on class 2 would be
  1557. instantly outdated as soon as class 2.0 was accepted.  (The final changes were
  1558. sent out for hopefully the final ballot the first week of March.  We are trying
  1559. to find out what the results were.)  
  1560.  
  1561. As far as the problem switching down to 4800, either this is a problem with the
  1562. software or with the current ROMs.  The current ROMs have a number of problems
  1563. working correctly with class 2 software.  The new ROMS, which will be available
  1564. in 2 weeks, resolve all known class 2 problems.    Again you are incorrect that
  1565. all you would need are the error codes and you would know what the problem is.
  1566. The error codes that are sent back are generally only useful if you understand
  1567. the t.4 and t.30 docs as they are refering to information and concepts that are
  1568. presented in those docs.  Ex. "NoRspons - No responce to DIS", "DCN err", or my
  1569. favorite "FailedTR - Failed to train"  Which means that there was a problem
  1570. changing to a lower baud rate, but why, one side or the other or software?  It
  1571. turns out that this particular problem I ran up against while testing was due
  1572. to a number of older fax machines not replying correctly after receiving a
  1573. page. 
  1574.  
  1575. Writing fax software is not trivial.  There are a number of different fax chip
  1576. manufactores who do things slightly differently.  There are a number of fax
  1577. machine quirks that must be known, all in all, it is not simple.  Correctly
  1578. written software does not require you to know ANYTHING about these standards,
  1579. all it needs to do is know what standard it supports, Sierra, Exar, Class 1,
  1580. Class 2. 
  1581.  
  1582.  
  1583.  
  1584. Msg#:  279 *MODEM*
  1585. 05-28-92 02:33:16
  1586. From: MICHAEL WALTERS
  1587.   To: MIKE DAHMS (Rcvd)
  1588. Subj: REPLY TO MSG# 170 (SUPRA FAX COMMAND SET)
  1589. MD> I'M with you Michelle, Although I use the modem for bbs MD> purposes, I had
  1590. the idea in mind that the FAX commands MD> would have at least been included in
  1591. the manual. onsumors as little as possible on the premise that we're all nearly
  1592. brain dead and any information we may be given would result in injering
  1593. ourselvs.
  1594.     Fact is, some of us actually do know how to set the clock on our VCR and if
  1595. given a minimum of information we might just be able to solve problems ourselvs
  1596. and take some of the burden off survice reps.
  1597.  
  1598.  
  1599. Msg#:  280 *MODEM*
  1600. 05-28-92 02:36:12
  1601. From: MICHAEL WALTERS
  1602.   To: MIKE DAHMS (Rcvd)
  1603. Subj: REPLY TO MSG# 170 (SUPRA FAX COMMAND SET)
  1604. MD> I'M with you Michelle, Although I use the modem for bbs MD> purposes, I had
  1605. the idea in mind that the FAX commands MD> would have at least been included in
  1606. the manual.
  1607.  
  1608.     Thanks. Since I posted that I was told that there's a lamentable trend in
  1609. the electronics industry to tell us consumors as little as possible on the
  1610. premise that we're all nearly brain dead and any information we may be given 
  1611. would result in injering ourselvs.
  1612.     Fact is, some of us actually do know how to set the clock on our VCR and if
  1613. given a minimum of information we might just be able to solve problems ourselvs
  1614. and take some of the burden off survice reps.
  1615.  
  1616. MD> other then not beinmg able to use the FAX function I MD> like the modem...
  1617.  
  1618.     Same here. Aside from the SMT LM386 audio amp with the tacked on 10uf cap
  1619. and that tiny speaker taped to the top of an IC I think it's the best
  1620. engineered peice of equipment I've seen in a long time and ever since my first
  1621. 2400baud supra I've always liked the idea of that thick, one peice aluminum 
  1622. case that you could run over with a truck. Try that with just about any other
  1623. modem.
  1624.     Don't get me wrong, I may have complaints but just like democracy, it's the
  1625. best thing we've got.
  1626.  
  1627.  
  1628.  
  1629. Msg#:  287 *MODEM*
  1630. 05-28-92 15:52:25
  1631. From: MICHAEL PAUL
  1632.   To: SCOTT LEE (Rcvd)
  1633. Subj: V.32BIS CONNECTIONS
  1634. Well, since I haven't called back yet on the 2400 line, I don't know.
  1635.  
  1636. Even funnier, I had to make this call from work since I can't connect to THIS
  1637. BBS since the weekend.  Other places, fine.  This one, I get 144, then 120,
  1638. then 3 on the LED display, then it hangs up.
  1639.  
  1640. Oh, I can't wait for the phone bill...
  1641.  
  1642.  
  1643. Msg#:  316 *MODEM*
  1644. 05-29-92 13:29:29
  1645. From: PAUL BUTTERWORTH
  1646.   To: MIKE DAHMS (Rcvd)
  1647. Subj: REPLY TO MSG# 287 (V.32BIS CONNECTIONS)
  1648. Well running six modems I haven't fount any term yet to match the jrcomm 102a
  1649. that I run....the others may have more ...but jrcomm seems to be easy and bug
  1650. free!!!!
  1651.  
  1652.  
  1653. Msg#:  356 *MODEM*
  1654. 06-01-92 15:40:18
  1655. From: MICHAEL PAUL
  1656.   To: MIKE DAHMS (Rcvd)
  1657. Subj: REPLY TO MSG# 316 (V.32BIS CONNECTIONS)
  1658. Another BBS number.  Just what I'm looking for.
  1659.  
  1660. No success getting through from home lately.  Last night this modem (or its
  1661. twin) "answered" but I got no connect.  If I can't get through here, I think
  1662. I'll have to rethink using the main serial port.  I had been using my 2232
  1663. serial card, but when throughputs on 500's were 2000 cps and I'd seen 1050 ONCE
  1664. with an AdSpeed accelerator, I figured something needed changing.
  1665.  
  1666. I'm using an init string of AT&F2S8=1S0=0 (I had problems with the modem
  1667. misdialing, so I slowed it down with commas like 1-901,353,5278, and set S8=1
  1668. so the pause was 1 second.)  Other BBS's seem to work, but not this one.  I'm
  1669. far from concerned YET, but if Supra has a setup pamphlet that has been
  1670. verified to get people 2000 cps downloads off Amiga 2000's I really want to
  1671. read it.
  1672.  
  1673. Later...
  1674.  
  1675.  
  1676. Msg#:  290 *MODEM*
  1677. 05-28-92 16:48:00
  1678. From: SYSOP
  1679.   To: CHUCK (Rcvd)
  1680. Subj: ROM UPGRADE
  1681. Chuck,  Please leave me your full name and address here, and I will put you on
  1682. the list. [Nathan]  Supra Technical Support
  1683.  
  1684.  
  1685. Msg#:  322 *MODEM*
  1686. 05-29-92 22:35:11
  1687. From: CHUCK BERTOLINO
  1688.   To: SYSOP (Rcvd)
  1689. Subj: REPLY TO MSG# 290 (ROM UPGRADE)
  1690. Mname and address per your request. Chuck Bertolino 3224 Chicago  St.  San
  1691. Diego, CA 92117
  1692.  
  1693. Thanks
  1694.  
  1695.  
  1696. Msg#:  442 *MODEM*
  1697. 06-03-92 13:08:49
  1698. From: DARREK KAY
  1699.   To: SYSOP (Rcvd)
  1700. Subj: REPLY TO MSG# 290 (ROM UPGRADE)
  1701. Make sure that I'm on the list. Darrek Kay 147 Sackett Hall Corvallis, OR
  1702. 97331-1501 but please ship to: 906 N.E. Hood St. Hillsboro, OR 97124
  1703.  
  1704. Darrek Kay (503)737-9410
  1705.  
  1706.  
  1707.  
  1708.  
  1709. Msg#:  457 *MODEM*
  1710. 06-03-92 22:04:07
  1711. From: STEVE DRESSLER
  1712.   To: SYSOP (Rcvd)
  1713. Subj: REPLY TO MSG# 290 (ROM UPGRADE)
  1714. Please add me to the list as well
  1715.  
  1716.  6324 South 114 East Ave,
  1717.  Broken Arrow, Ok. 74012
  1718.  
  1719.  Is this a free upgrade?  
  1720.  
  1721.  
  1722. Msg#:  599 *MODEM*
  1723. 06-09-92 08:26:00
  1724. From: SYSOP
  1725.   To: CHUCK BERTOLINO (Rcvd)
  1726. Subj: REPLY TO MSG# 322 (ROM UPGRADE)
  1727. I have put your name on the list.  It is simply to be sure that you will
  1728. receive the upgrade.  We have finalized plans for the upgrade.  It will be
  1729. shipped out automatically to all registered users free of charge.  It will be
  1730. sent starting in mid July. [Nathan]  Supra Technical Support
  1731.  
  1732.  
  1733. Msg#:  600 *MODEM*
  1734. 06-09-92 08:30:38
  1735. From: SYSOP
  1736.   To: DARREK KAY (Rcvd)
  1737. Subj: REPLY TO MSG# 442 (ROM UPGRADE)
  1738. I have put your name on the list.  It is simply to be sure that the upgrade
  1739. will be shipped to you.  We will start shipping in mid July.  It will be free
  1740. of charge. [Nathan]  Supra Technical Support
  1741.  
  1742.  
  1743. Msg#:  601 *MODEM*
  1744. 06-09-92 08:31:53
  1745. From: SYSOP
  1746.   To: STEVE DRESSLER (Rcvd)
  1747. Subj: REPLY TO MSG# 457 (ROM UPGRADE)
  1748. Yes, this is a free upgrade. Supra Corp
  1749.  
  1750.  
  1751. Msg#:  684 *MODEM*
  1752. 06-12-92 00:42:10
  1753. From: SCOTT PIERCY
  1754.   To: SYSOP (Rcvd)
  1755. Subj: REPLY TO MSG# 600 (ROM UPGRADE)
  1756. Hiya! I sent in my registration card but forgot to write the darn serial number
  1757. on it! :-( (yes, call me stupid). The Serial number is 14e 900001 Here's my
  1758. address too! ;-) Scott Piercy 112 Rosemary Rd. Spartanburg, S.C.29301
  1759.  
  1760. Hiy
  1761.  
  1762. .
  1763.  
  1764.  
  1765. Msg#: 1095 *MODEM*
  1766. 06-22-92 09:54:41
  1767. From: SYSOP
  1768.   To: CHUCK BERTOLINO
  1769. Subj: REPLY TO MSG# 322 (ROM UPGRADE)
  1770. Chuck, You're on the list. [Nathan]
  1771.  
  1772.  
  1773. Msg#: 1304 *MODEM*
  1774. 06-26-92 15:01:06
  1775. From: GEORGE RICHARDSON
  1776.   To: SYSOP
  1777. Subj: REPLY TO MSG# 599 (ROM UPGRADE)
  1778. Hello Guys,
  1779.   I don't see me name in the card file, but it should be showing up soon.  I
  1780. seem to be having the same problems as everyone else, FAX don't work but the
  1781. rest of the modem is doing great.  I understand that the new ROMs will fix the
  1782. FAX problems.  Put me on the list ASAP, as the FAX capability was the reason I
  1783. bought the modem in the first place.
  1784.                           George Richardson
  1785.                           3750 Davis Ford Road
  1786.                           Maryville, TN 37804
  1787.                           (615)982-3881
  1788.  
  1789.  
  1790. Msg#:  414 *MODEM*
  1791. 06-03-92 00:07:55
  1792. From: TIM HARRIS
  1793.   To: CHUCK (Rcvd)
  1794. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1795. I would also like some info on the rom upgrade.  Is it possible for me to get
  1796. it directly from you guys?  I work across the street at LBCC so it would be
  1797. most convienient for me to walk over there at lunch.  Our department(computer
  1798. services) also has 6 of these modems and have had some trouble connecting at
  1799. 14.4 with other supras(namely mine :( ).  If you could call me at work with a
  1800. reply it would be greatly appreciated(8am-5pm)    work# 967-6506 ask for Tim 
  1801. Tim Harris
  1802.  
  1803.  
  1804. Msg#:  418 *MODEM*
  1805. 06-03-92 02:51:53
  1806. From: ELVIN EMERY
  1807.   To: CHUCK (Rcvd)
  1808. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1809. Put me on the list also.  Elvin E. Emery 8724 Raven Ave.   OKC OK 73132
  1810.  
  1811.  
  1812.  
  1813. Msg#:  419 *MODEM*
  1814. 06-03-92 06:27:13
  1815. From: KERRY COLE
  1816.   To: CHUCK (Rcvd)
  1817. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1818. Put me on the ROM list-----  Kerry C 3901 W. 141st Drive, Leawood, Kans 66224.
  1819.  
  1820.  
  1821.  
  1822.  
  1823. Msg#:  444 *MODEM*
  1824. 06-03-92 15:09:37
  1825. From: GENE STEINBERG
  1826.   To: TIM HARRIS (Rcvd)
  1827. Subj: REPLY TO MSG# 414 (ROM UPGRADE)
  1828. Yes, put me on the list for the ROMS too (do you send a tool with it?): Gene
  1829. Steinberg, 422 Westgate Drive, Edison, NJ 08820-1172. Any AOL users out there:
  1830. You can find me online as AFA GeneS. I hang out in the Mac Operating Systems
  1831. Forum. Peace, Gene
  1832.  
  1833.  
  1834. Msg#:  453 *MODEM*
  1835. 06-03-92 20:51:23
  1836. From: BOB SHATTLER
  1837.   To: CHUCK (Rcvd)
  1838. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1839. Add my name to the rom update listing: Bob Shattler 13522 Wake Ave. Irvine, Ca.
  1840. 92714
  1841.  
  1842.  
  1843. Msg#:  473 *MODEM*
  1844. 06-04-92 20:09:59
  1845. From: JAMES HUSSIERE
  1846.   To: TIM HARRIS (Rcvd)
  1847. Subj: REPLY TO MSG# 414 (ROM UPGRADE)
  1848. If you could add me to the ROM upgrade list...
  1849.  
  1850. James A. Hussiere, Star Route Box 160, Poland Spring, ME 04274
  1851.  
  1852. (Even though I'm in New York, my mail can be most reliabily sent to Maine.)
  1853.  
  1854.  
  1855. Msg#:  485 *MODEM*
  1856. 06-05-92 11:46:55
  1857. From: KIRK BLUM
  1858.   To: CHUCK (Rcvd)
  1859. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1860. Hello, I just received my SupraFAX v.32bis serial #14e900001 and would liketo
  1861. be put on the ROM upgrade list.  Kirk Blum 1844 Rosswood Dr. San Jose, CA 95124
  1862. W-408-370-7979x315
  1863.     
  1864. Could Nathan call me about some problems I am experiencing with FAX and data
  1865. transmissions??  I'm having trouble at 9600 FAX transmissions (it get garbled
  1866. on the other end) and if I do a ^X such as to abort a download, the modem hangs
  1867. up.  Am I doing something drastically wrong??
  1868.   THX  Kirk
  1869.  
  1870.  
  1871. Msg#:  603 *MODEM*
  1872. 06-09-92 08:34:27
  1873. From: SYSOP
  1874.   To: TIM HARRIS (Rcvd)
  1875. Subj: REPLY TO MSG# 414 (ROM UPGRADE)
  1876. I'll give you a call. [Nathan]  Supra Technical Support
  1877.  
  1878.  
  1879. Msg#:  605 *MODEM*
  1880. 06-09-92 08:36:16
  1881. From: SYSOP
  1882.   To: ELVIN EMERY (Rcvd)
  1883. Subj: REPLY TO MSG# 418 (ROM UPGRADE)
  1884. You're on the list.  Please be sure to also send in your registration card.  It
  1885. will be shipped out fre of charge to all registered users, starting mid July. 
  1886. [Nathan]  Supra Technical Support
  1887.  
  1888.  
  1889. Msg#:  606 *MODEM*
  1890. 06-09-92 08:41:03
  1891. From: SYSOP
  1892.   To: KERRY COLE (Rcvd)
  1893. Subj: REPLY TO MSG# 419 (ROM UPGRADE)
  1894. OK.  You're on the list.  It is simply to be sure that you receive the upgrade.
  1895. We will be sending the upgrade free of charge to all registered users.  It
  1896. should start shipping mid July. [Nathan]  Supra Technical Support
  1897.  
  1898.  
  1899. Msg#:  607 *MODEM*
  1900. 06-09-92 08:44:27
  1901. From: SYSOP
  1902.   To: KIRK BLUM (Rcvd)
  1903. Subj: REPLY TO MSG# 485 (ROM UPGRADE)
  1904. I'll give you a call. [Nathan]
  1905.  
  1906.  
  1907. Msg#:  787 *MODEM*
  1908. 06-14-92 21:45:44
  1909. From: GAUTHAM MALLAMPATI
  1910.   To: CHUCK (Rcvd)
  1911. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1912. please place my name on the list gautham mallampati, 500 w. university pky apt
  1913. 5r, balto md 21210
  1914.  
  1915.  
  1916. Msg#:  931 *MODEM*
  1917. 06-18-92 00:05:39
  1918. From: BRIAN COLLIER
  1919.   To: CHUCK (Rcvd)
  1920. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1921. Please add me to the list for receiving a ROM upgrade for the Supra V.32bis
  1922. modem. My serial number is: 14E 012513. I would also like to receive
  1923. information on the voice mail/call I.D. upgrade. Thanks
  1924.  
  1925. Address: Brian B. Collier
  1926.          11131 Poachers Run
  1927.          Chesterfield, VA 23832
  1928.  
  1929. Phone: (804)744-7872
  1930.  
  1931.  
  1932. Msg#: 1094 *MODEM*
  1933. 06-22-92 09:53:18
  1934. From: SYSOP
  1935.   To: CHUCK
  1936. Subj: REPLY TO MSG# 160 (ROM UPGRADE)
  1937. We will offer caller I.D and voice recognition as an upgrade this Fall.  I
  1938. don't have an exact date. [Nathan]  Supra Technical Support
  1939.  
  1940.  
  1941. Msg#: 1096 *MODEM*
  1942. 06-22-92 09:58:07
  1943. From: SYSOP
  1944.   To: TIM HARRIS
  1945. Subj: REPLY TO MSG# 414 (ROM UPGRADE)
  1946. Tim, We'll have the new ROMs available in mid-July.  If you must have them now,
  1947. we can give them to you for $14.95 each set.  It's worth the wait until July,
  1948. as those chips will also have fall forward capability.  [Nathan]  Supra
  1949. Technical Support
  1950.  
  1951.  
  1952. Msg#:  292 *MODEM*
  1953. 05-28-92 17:28:32
  1954. From: WHITNEY QUESENBERY
  1955.   To: SUPRA
  1956. Subj: ANSWER TO MY QUESTION
  1957. I left a question here a few days ago, with no reply. I'm tring to figure out
  1958. why my FAX machine gets a busy signal every time I boot my computer with new
  1959. Supra V32bis modem.Doesn't happen if I turn the modem off and on. Never used to
  1960. happen with my old modem. The modem is not set to AutoAnswer - is it polling
  1961. the line? How can I make it stop?
  1962.  
  1963.  
  1964. Msg#:  293 *MODEM*
  1965. 05-28-92 18:53:40
  1966. From: MARY PINCKARD
  1967.   To: SYSOP (Rcvd)
  1968. Subj: TRADE-INS
  1969. I am considering buying the v32bis at the sysop price.  I may have d/l'ed this
  1970. information already and not read it yet, but is there a trade-in on the old
  1971. Supra modems?  I currently have a Supra Modem 2400.  If so, how much?
  1972.  
  1973. Btw, I like this BBS software *MUCH* better. :-)
  1974.  
  1975. Mary Pinckard
  1976.  
  1977.  
  1978. Msg#:  434 *MODEM*
  1979. 06-03-92 12:24:52
  1980. From: SYSOP
  1981.   To: MARY PINCKARD
  1982. Subj: REPLY TO MSG# 293 (TRADE-INS)
  1983. The sysop deal is simply a stand alone modem.  There is no trade in policy with
  1984. it.  However, we do have a trade in policy.  You can receive approximately $100
  1985. for your old modem.  That is, a credit against the full price of the new V.32
  1986. or V.32bis modem. [Nathan]  Supra Technical Support
  1987.  
  1988.  
  1989. Msg#:  301 *MODEM*
  1990. 05-29-92 04:49:00
  1991. From: OYVIND FREDRIKSEN
  1992.   To: TECH SUPPORT
  1993. Subj: MODEM-TROUBLE
  1994. Dear Sirs,
  1995.  
  1996.  
  1997. Msg#:  304 *MODEM*
  1998. 05-29-92 10:14:23
  1999. From: SYSOP
  2000.   To: DONALD WATSON (Rcvd)
  2001. Subj: BUG WHILE PULSE DIALING
  2002. Try resetting the modem with (ATZ) and then re-dial. [Nathan]  Supra Tehnical
  2003. Support
  2004.  
  2005.  
  2006. Msg#:  305 *MODEM*
  2007. 05-29-92 10:16:17
  2008. From: SYSOP
  2009.   To: MIKE DAHMS (Rcvd)
  2010. Subj: ROM UPGRADES
  2011. Mike, We will be contacting you about future upgrades, including the one that
  2012. will be ready in about 3 to 4 weeks. [Nathan]  Supra Technical Support
  2013.  
  2014.  
  2015. Msg#:  306 *MODEM*
  2016. 05-29-92 10:17:23
  2017. From: SYSOP
  2018.   To: DEWEY E HYLTON
  2019. Subj: REPLY TO MSG# 305 (ROM UPGRADES)
  2020. We will contact you about future upgrades, providing you sent in your
  2021. registration card. [Nathan]  Supra Technical Support
  2022.  
  2023.  
  2024. Msg#:  510 *MODEM*
  2025. 06-06-92 13:18:07
  2026. From: MIKE DAHMS
  2027.   To: SYSOP (Rcvd)
  2028. Subj: REPLY TO MSG# 305 (ROM UPGRADES)
  2029. Thanks Nathan...will be looking forward to it. 
  2030.  
  2031.  
  2032. Msg#:  869 *MODEM*
  2033. 06-16-92 09:22:10
  2034. From: SYSOP
  2035.   To: MIKE DAHMS
  2036. Subj: REPLY TO MSG# 510 (ROM UPGRADES)
  2037. Mike, Just a note: We will send the new ROMs to all registered owners of the
  2038. V.32 and V.32bis in mid July. [Nathan]
  2039.  
  2040.  
  2041. Msg#:  307 *MODEM*
  2042. 05-29-92 10:18:21
  2043. From: SYSOP
  2044.   To: RICHARD EINHORN
  2045. Subj: ROM UPGRADE
  2046. OK.  We will be contacting you if you have sent in your registration card. 
  2047. [Nathan]  Supra Technical Support.
  2048.  
  2049.  
  2050. Msg#:  308 *MODEM*
  2051. 05-29-92 10:21:53
  2052. From: SYSOP
  2053.   To: GERGELY J. TAPOLYAI (Rcvd)
  2054. Subj: &T
  2055. Sorry for the delay in responding.  You need to set the modem to 9600 and &Q0.
  2056. The whole command is (AT N S37=9 &Q0)  Then the &T test command will work. 
  2057. [Nathan]  Supra Technical Support
  2058.  
  2059.  
  2060. Msg#:  310 *MODEM*
  2061. 05-29-92 10:33:45
  2062. From: CHARLES KUTTNER
  2063.   To: MARK WHITE (Rcvd)
  2064. Subj: ROM UPGRADE
  2065. Mark, I hope all is well in your world. Stan Roach mentioned a couple of months
  2066. ago that the Supra Fax Modem (my ser. no. is 817883) is to be getting some type
  2067. of ROM upgrade. You folks have already replaced the resistor or whatever that
  2068. mod was. I am happy with the modem, altho I occasionally can't successfully fax
  2069. to someone. You have been great about sending software upgrades.
  2070.   Anyway, is this upgrade in the works? Also, Stan mentioned that you guys were
  2071. soon to come out with an accelerator for a Mac SE. My wife may be in the market
  2072. for one. When should I pull my checkbook out of my pocket? [or do you need any
  2073. Beta testers???]
  2074.   Best regards...feel free to leave me a reply here, or call my office in
  2075. Albany, 928-1678. Peace.
  2076.  
  2077.  
  2078. Msg#:  344 *MODEM*
  2079. 05-31-92 23:10:30
  2080. From: MARK WHITE
  2081.   To: CHARLES KUTTNER (Rcvd)
  2082. Subj: REPLY TO MSG# 310 (ROM UPGRADE)
  2083. Well.....it turns out that STF has not implemented what is needed to use the
  2084. fixed ROMs, so the new ROMS will effectivly only add MNP10.  But don't worry,
  2085. we are sending out STF's class 1 software (v2.2) which allows both manual send
  2086. and call grouping.  We have typed in all of our 2400 Mac fax registration
  2087. cards, so we are just about ready to do an update mailing to those customers.
  2088.  
  2089.  
  2090. Msg#:  477 *MODEM*
  2091. 06-04-92 22:05:32
  2092. From: CHARLES KUTTNER
  2093.   To: MARK WHITE (Rcvd)
  2094. Subj: REPLY TO MSG# 344 (ROM UPGRADE)
  2095. Thanks, Mark. I see all the nasty mail directed at you about the new modem's
  2096. glitches, and I see great opportunity for stress intervention!
  2097.  I, for one, appreciate you and the rest of tech support.
  2098.  
  2099.  
  2100. Msg#:  326 *MODEM*
  2101. 05-30-92 00:07:50
  2102. From: LEON WRIGHT
  2103.   To: SYSOP (Rcvd)
  2104. Subj: FAX
  2105.  I am currently experiencing a problem with my SupraFAXModem, It seems that
  2106. using the fax software that was shipped with it, it can connect to a normal fax
  2107. machine and either send or receive. But when connecting to a Fax/modem it can
  2108. only receive. I am also experiencing a problem with the fax software loseing
  2109. pages it will take the odd pages of a fax but lose the even pages. I am using
  2110. FaxTalk+ software. I would appreciate any help with these problems. 
  2111.  
  2112.  
  2113. Msg#:  328 *MODEM*
  2114. 05-30-92 13:46:29
  2115. From: DAVID SMITH
  2116.   To: TECH SUPPORT
  2117. Subj: FAX MODE AND RESET ON DTR DROP
  2118. I've been playing with the my V.32bis Supra FAX modem and I've noticed that if
  2119. I put the modem into FAX mode (AT+FCLASS=2) it no longer resets when DTR is
  2120. dropped.  Since I have this hooked up to a Unix system and I use it as my
  2121. dial-in line, it's important that it resets back to a known state when after a
  2122. FAX is sent, even if the FAX software or the system crashes in the middle.  Is
  2123. ignoring DTR in FAX mode intentional or is this a bug that will be fixed in
  2124. another release of the ROMS?Dave Smith (619)455-2529 (work)
  2125.  
  2126.  
  2127.  
  2128.  
  2129. Msg#:  347 *MODEM*
  2130. 05-31-92 23:27:35
  2131. From: MARK WHITE
  2132.   To: DAVID SMITH
  2133. Subj: REPLY TO MSG# 328 (FAX MODE AND RESET ON DTR DROP)
  2134. The fax modem is working correctly, per the CCITT standard.  I have some more
  2135. information on this, but I will need to dig it up.
  2136.   
  2137. Class 2 spec calls for the modem NOT to hangup on toggle of DTR.)
  2138.  
  2139.  
  2140. Msg#:  719 *MODEM*
  2141. 06-12-92 23:40:44
  2142. From: DAVE SMITH
  2143.   To: MARK WHITE (Rcvd)
  2144. Subj: REPLY TO MSG# 347 (FAX MODE AND RESET ON DTR DROP)
  2145. Ahem...I've been playing with the modem a bit (my class 2 spec is in the mail -
  2146. EIA wants a fortune for the damn things) and I've discovered a couple of
  2147. things.  One, the auto modem determination is broken (AT+FAA=1) - it comes in
  2148. FAX mode the first time some one dials in then it won't answer in modem mode.
  2149. However, the second time some one dials in it answers appropriately.  More
  2150. interesting, though, is that the Supra will respond to DTR and reset itself
  2151. after it has been  called once.  So, which is the correct behavior?  Since it
  2152. responds to DTR sometimes and not others one of the two must be a bug.  DO the 
  2153. new modems fix this behavior?  (BTW The class 1 spec (which I have in my hot
  2154. little hands) makes no mention of DTR.  Somehow I doubt the class 2 spec does
  2155. either) Dave Smith
  2156.  
  2157.  
  2158. Msg#:  738 *MODEM*
  2159. 06-13-92 11:11:28
  2160. From: MARK WHITE
  2161.   To: DAVE SMITH (Rcvd)
  2162. Subj: REPLY TO MSG# 719 (FAX MODE AND RESET ON DTR DROP)
  2163. What vers of our ROMs are you using (AT I3).  Depending on the ROM vers as to
  2164. how well FAA works.  The older vers work better.  That is correct, DTR has not
  2165. been doced in the Class 1 or 2 specs.  We have just implemented it as &D2 works
  2166. on the data side.  But this is not yet avail, it will be mid-july.
  2167.  \
  2168. Mark - Supra Tech Support
  2169.  
  2170.  
  2171. Msg#:  331 *MODEM*
  2172. 05-30-92 19:35:01
  2173. From: KEVIN O'CONNOR
  2174.   To: SYSOP (Rcvd)
  2175. Subj: V.32BIS PROBLEMS
  2176. The following is a list of bugs and problems I've encountered while using your
  2177. V32bis SupraFaxModem.
  2178.  
  2179. 1. The W1 call progress setting does not work. When I have the W1 setting 
  2180. active, all I get is a CONNECT 38400 (which is the modem-computer speed). I'm
  2181. using Telix 3.15, with the following Telix settings: XON/XOFF           Off 
  2182. DSR/DTR            Off CTS/RTS            On Auto Baud Detect   Off
  2183.  
  2184. My modem has the following settings:
  2185.  
  2186. ACTIVE PROFILE: B0 E1 L2 M1 N1 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R0 &S0
  2187. &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:050
  2188. S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S25:005 S26:001 S36:004 S37:000
  2189. S38:020 S44:003 S46:138 S48:007 S49:008 S50:255 
  2190.  
  2191. 2. The modem seems to be incompatible with the modems on Rusty & Edie's BBS. To
  2192. try for yourself, dial 1-216-726-3589. These are V.32bis modems. I also have
  2193. similar problems connecting to your BBS. After getting connected to Rusty &
  2194. Edie's, I get just a CONNECT 38400 (even with the W1 setting active) and then a
  2195. couple of screens of garbage before the connection is lost. The modem displays
  2196. 144 and CD. I get the same thing when calling the Supra BBS except that the
  2197. garbage is a consistent ~? pattern.
  2198.  
  2199. 3. The dump of the current settings (AT&V) does NOT include many of the 
  2200. settings such as the % and \ settings. This makes debugging very difficult.
  2201.  
  2202. 4. What does the &G command do? It's displayed by &V, but not documented.
  2203.  
  2204. 5. Some codes on the modem display are not documented anywhere.
  2205.  
  2206. 6. The *H command just returns an error.
  2207.  
  2208. 7. Why isn't there a \J command? Is the baud rate always locked?
  2209.  
  2210. 8. The only modem test commands that don't produce an ERROR response are &T4
  2211. and &T5. All others produce an immediate ERROR result.
  2212.  
  2213. 9. The reference card documents the range of the S37 register as 0-6, but the
  2214. reference manual lists 1,5,6,8,9,10,11, and 12 as valid values. Also, the
  2215. refenence manual documents the range for this register as 0-7.
  2216.  
  2217. This is from just one day of playing with the modem. I'm very dissapointed in
  2218. the performance in the above areas. I beta tested a modem for another 
  2219. manufacturer and in a lot of ways their first Beta was further along than this
  2220. modem. I hope these problems are my fault, especialy number 2. I'd like to be
  2221. able to use it, but all it gives me now are lots of 10s long distance calls
  2222. with an occasional good connection. If you need any more details on any of the
  2223. problems you can reach me during the day at (317) 254-4545 ext. 4589 or during
  2224. the evening at (317) 253-8733.
  2225.  
  2226.  
  2227.  
  2228. Msg#:  348 *MODEM*
  2229. 05-31-92 23:55:28
  2230. From: MARK WHITE
  2231.   To: KEVIN O'CONNOR (Rcvd)
  2232. Subj: REPLY TO MSG# 331 (V.32BIS PROBLEMS)
  2233. 1.  The W1 command does work.  If it is not working correctly for you,     then
  2234. somehow the modem is being reset by Telix.  How are you setting     the modem
  2235. to the W1 command?  After doing a AT W1[CR], do a ATDT xxx,     DO NOT let
  2236. Telix dial for you, this will show that it is working     correctly.
  2237.  
  2238. 2.  The problem is due to line noise.  You can set the modem for 9600 and
  2239. it will most likely work.  (AT NS37=9[CR])  Please see V32_Q&A.TXT in     the
  2240. MODEM area for more information.  Shortly, we will have a new ROM     which
  2241. implements the OPTIONAL feature of v32bis of initiating a fall     back on bad
  2242. phone lines.
  2243.  
  2244. 3.  There is only so much information that can be displayed on one 24x80
  2245.      screen.  To display all the parameters would require more than one s
  2246.     screen, (remember Active, Stored 1, Stored 2 for a total of 20 lines
  2247. already.)
  2248.  
  2249. 5.  What display codes are not documented?
  2250.  
  2251. 6.  The *H command is for MNP10, which is currently not implemented yet.
  2252. Please remember, the manual was written before the modem was ready to     ship,
  2253. so there are a few minor areas that are incorretly doced.
  2254.  
  2255. 7.  What is thej \J command suppose to do?
  2256.  
  2257. 8.  The &T commands are not correctly doced.  They do work, but you must
  2258. set the modem up correctly.  I do not have the info right in front of     me.
  2259.  
  2260.  
  2261. Msg#:  359 *MODEM*
  2262. 06-01-92 18:31:42
  2263. From: KEVIN O'CONNOR
  2264.   To: MARK WHITE (Rcvd)
  2265. Subj: REPLY TO MSG# 348 (V.32BIS PROBLEMS)
  2266. I've narrowed down the W1 problem. I get the full response in W1 mode when the
  2267. \N3 mode is active. When set to \N4 or \N2, all that comes back is a 'CONNECT
  2268. n' where n is the DTE speed. Yes I did test this all interactivly by typing AT
  2269. commands, including dialing.
  2270.  
  2271. I can't believe that my 14.4 problems are due to line noise. I can't reliably
  2272. connect to an modem at 14.4. If I'm in the W1 and \N3 modes, I see CARRIER
  2273. 14400, and then lots of garbage. If I look carefully at the garbage, I can make
  2274. out the rest of the response which includes PROTOCOL: NONE. I know the modem at
  2275. the other end has LAPM and MNP. I assume your modem on this BBS is also working
  2276. in reliable mode. It appears that my modem is not detecting that reliable mode
  2277. is available, but the other side is. Are you telling me this is caused by line
  2278. noise? How will the new ROM fix this, I assume you would have to get some sort 
  2279. of connection before you could tell the other modem to fall back. Also, if I
  2280. set S37=9 and N0, I still get garbage when calling Rusty and Edie's
  2281. (216-726-3589). Same result code (including PROTOCOL: NONE). The modem is
  2282. incorrectly determining that it does not have a reliable connection. I can
  2283. throw my Everex V.32 in and get a 9600, LAPM connection over and over again.
  2284.  
  2285. As for the AT&V, I think the seeing all the settings is much more important
  2286. than worrying about them scrolling off a 25 line screen. Maybe you should add
  2287. another command that displays the rest of the settings, such as AT&V1 and AT&V2
  2288. etc. Better yet, use those commands to display the stored settings. Either way,
  2289. there should be some way to inquire what these settings are. It must be hell
  2290. for your tech support.
  2291.  
  2292. I've seen two status codes that I couldn't find in the manual or reference. I
  2293. didn't have anything to write with at the time, so I can't tell you what they
  2294. were. If I see them again, I'll write them down and report them here.
  2295.  
  2296. The \J command tells the modem to lock the DTE rate at the current speed. This
  2297. is as opposed to adjusting the rate to match the carrier.
  2298.  
  2299. I've come across a couple new things: There seems to be a difference between N1
  2300. S37=0 and N0 S37=0. Both settings should connect at the highest speed possible.
  2301. When I call the local Compuserve 9600 baud line (317) xxx-xxxx I get no carrier
  2302. with the N0 S37=0 mode, but I get a 96 connection with the N1 S37=0 mode.
  2303.  
  2304. The speaker sound is poor for the remote end. You have to turn it up really 
  2305. loud to listen to the call progress, and then you get blasted by the local 
  2306. sound of the modem dialing and handshaking.
  2307.  
  2308. I can be reached in the daytime at (317) 254-4545 ext 4589 and in the evening
  2309. at (317) 253-8733
  2310.  
  2311.  
  2312. Msg#:  424 *MODEM*
  2313. 06-03-92 11:02:19
  2314. From: KEVIN O'CONNOR
  2315.   To: MARK WHITE (Rcvd)
  2316. Subj: REPLY TO MSG# 348 (V.32BIS PROBLEMS)
  2317. Well, thanks to another user on this BBS, I've got my Supra talking 14.4 to
  2318. every modem I've tried so far. The solution was to set &Q9, which is yet
  2319. another undocumented AT command. Now that I can reliably connect at 14.4
  2320. (approx 1690 cps downloads), are you still going to tell me that the reason I
  2321. can't connect with the documented setting (&Q5) is line noise? This is a BUG!!!
  2322. How many people are having this problem and just getting blown off by you guys
  2323. under the excuse of line noise!
  2324.  
  2325. I've got mixed feelings about this modem. In most ways the quality looks really
  2326. good. But the tech support isn't that great. I've no idea what the voice
  2327. support is like, I've never got anything but a busy signal on the tech support
  2328. line.
  2329.  
  2330. I hope you guys do more than add fallback to the new ROM. Maybe new docs would
  2331. be a good idea to.
  2332.  
  2333. By the way, when will the caller id upgrade be available? What for will it take
  2334. (ROM upgrade, hardware upgrade etc)?
  2335.  
  2336.  
  2337. Msg#:  493 *MODEM*
  2338. 06-05-92 19:37:07
  2339. From: CHUCK BERTOLINO
  2340.   To: KEVIN O'CONNOR (Rcvd)
  2341. Subj: REPLY TO MSG# 424 (V.32BIS PROBLEMS)
  2342. Kevin,
  2343.  
  2344. I share your frustrations, and thanks for the info on the &Q9, if that solves
  2345. the problem, I too will leave a nasty note about being shined with that line
  2346. noise excuse....I know the lines I make connections on aren't that
  2347. noisy...........I can't believe this excuse!
  2348.  
  2349.  
  2350.  
  2351. Msg#:  508 *MODEM*
  2352. 06-06-92 10:50:34
  2353. From: MARK WHITE
  2354.   To: KEVIN O'CONNOR (Rcvd)
  2355. Subj: REPLY TO MSG# 424 (V.32BIS PROBLEMS)
  2356. 1.  &Q9 not documented
  2357.    &Q9 is documented in the manual, but not on the reference card.
  2358.  
  2359. 2.  Since I can make 14.4 connections with &Q9, Supra Tech support is     wrong
  2360. about the line noise problems.
  2361.  
  2362. A.  This is incorrect.  What you are doing is cutting the amount of time     of
  2363. the negotiation process.  During the negotiation process, the line     quality
  2364. is being constantly checked and recorded.  At the end of the     process, if to
  2365. much line noise is recorded, the process is started     over again.  (This is a
  2366. simplified synopsis of what actually happens.)     This is why sometimes it can
  2367. take 40-60 seconds for the modem to     connect at 14.4.  Another aspect of
  2368. this process is that this is all      done at 4800, then the baud is jumped to
  2369. 14.4 and the modems tell you     that they have connected at 14.4.  BUT if when
  2370. the modems jump to 14.4     and one of those modems now is seeing a poor line,
  2371. it will then almost     immediatly drop to a lower rate.  (12K,9.6K,7.2K etc.).
  2372.  
  2373. 3.  "But the tech support isn't that great"
  2374.  
  2375. A.  We do not start out knowing everything about a subject.  Plus MUCH of
  2376. the knowledge needed to accurately answer these type of technical     questions
  2377. is NOT documented or documented incorrectly.  They only way     to correctly
  2378. answer these questions is to carry on intellegent     discussions, test, read,
  2379. test some more... and so on until the correct     answers are arrived at.  At
  2380. times we will not give out accurate     information, or we have the correct
  2381. information, but not enough     background info to accuratly explain it.  But
  2382. we are constantly     learning; learning the correct info and the best way to
  2383. explain highly     technical information to everyone, the beginner and the
  2384. expert.  We     pride ourselves on constantly improving and not being just a
  2385. static     technical support.
  2386.  
  2387. Mark Supra Tech Support
  2388.  
  2389.  
  2390. Msg#:  512 *MODEM*
  2391. 06-06-92 13:50:53
  2392. From: KEVIN O'CONNOR
  2393.   To: MARK WHITE (Rcvd)
  2394. Subj: REPLY TO MSG# 508 (V.32BIS PROBLEMS)
  2395. Sorry, I didn't check the manual (just the ref card) before concluding the &Q9
  2396. command was undocumented.
  2397.  
  2398. Negotiation time aside, the end result is still the same - I ca get a true 14.4
  2399. connection with V.42bis with &Q9 and not with &Q5. Why is this. Is it the line
  2400. quality that causes &Q5 decide not to use V.42 or V.42bis when the other modem
  2401. is trying to use it?
  2402.  
  2403. I'm not sure if you saw one of my previous messages (it got no replies), but
  2404. when this modem fails to connect with &Q5, I get CARRIER 14400, followed by
  2405. garbage. Whithin the garbage, I can always piece together the words PROTOCOL:
  2406. NONE, and I know the other modem has V.42bis. It looks to me like the Supra is
  2407. incorrectly determining that the PROTOCOL is NONE. Of course, if the other
  2408. modem is trying to communicate with V.42bis, this would explain the garbage and
  2409. swift disconnet from the other side.
  2410.  
  2411.  
  2412. Msg#:  550 *MODEM*
  2413. 06-07-92 22:50:08
  2414. From: MARK WHITE
  2415.   To: KEVIN O'CONNOR (Rcvd)
  2416. Subj: REPLY TO MSG# 512 (V.32BIS PROBLEMS)
  2417. I am not sure why, but I am certain that once you get the new ROM that you will
  2418. see the problems disappear.  Rockwell has fixed several slight connection
  2419. problems.  This could also explain the problem.  Whatever, I am certain that
  2420. the new ROM will make things work much better.
  2421.  
  2422. Mark Supra Tech Support
  2423.  
  2424.  
  2425. Msg#:  587 *MODEM*
  2426. 06-08-92 22:22:04
  2427. From: KEVIN O'CONNOR
  2428.   To: MARK WHITE (Rcvd)
  2429. Subj: REPLY TO MSG# 550 (V.32BIS PROBLEMS)
  2430. I'm looking forward to the new ROM if you think it will correct connection
  2431. problems. But, if all it does to correct them is fall back to a slower speed,
  2432. then that won't be good enough. As I said before, another brand of modem will
  2433. work on my lines at full speed.
  2434.  
  2435. It's not that I don't believe it will work, but none of the descriptions of
  2436. fixes in the new ROMs that I've read on this BBS have talked about improving
  2437. the connection and negotiation.
  2438.  
  2439. If it does fix it, then great. You've got one loyal user here. Would it be
  2440. possible for you to post a complete list of fixes here on the BBS?
  2441.  
  2442. If the ROM is going to take a long time to distribute, would you consider
  2443. putting a ROM image here for downloading for those that have the means to burn
  2444. their own ROMS?
  2445.  
  2446. One other question. Do you have any information on the Caller ID capabilities
  2447. of this modem? Will it be a ROM upgrade or additional hardware? What's the
  2448. planned availability?
  2449.  
  2450.  
  2451. Msg#:  655 *MODEM*
  2452. 06-11-92 01:09:16
  2453. From: MARK WHITE
  2454.   To: KEVIN O'CONNOR (Rcvd)
  2455. Subj: REPLY TO MSG# 587 (V.32BIS PROBLEMS)
  2456. How do you know that another v32bis is working at 14.4K?  Just because the
  2457. connect message says that it is running at 14.4, does not mean that it truly
  2458. is.
  2459.  
  2460. We will be mailing the ROMs to all registered owners.  
  2461.  
  2462. The caller id will most likely be a rom update.
  2463.  
  2464. [Mark] Supra Tech Support
  2465.  
  2466.  
  2467. Msg#:  679 *MODEM*
  2468. 06-11-92 20:54:38
  2469. From: KEVIN O'CONNOR
  2470.   To: MARK WHITE (Rcvd)
  2471. Subj: REPLY TO MSG# 655 (V.32BIS PROBLEMS)
  2472. How do I know the connection was at 14.4? Because I got 1600 cps throughput on
  2473. a ZIPped file (according to DSZ Zmodem). I doubt I could get that at 96 or even
  2474. 12.2! I thought I mentioned the CPS rate in my previous message. I guess not.
  2475.  
  2476. If it's not a design flaw in this modem, which it probably isn't since most the
  2477. other people on here aren't having this many problems, then maybe I just got a
  2478. bad modem?
  2479.  
  2480.  
  2481. Msg#:  734 *MODEM*
  2482. 06-13-92 11:01:39
  2483. From: MARK WHITE
  2484.   To: KEVIN O'CONNOR (Rcvd)
  2485. Subj: REPLY TO MSG# 679 (V.32BIS PROBLEMS)
  2486. That is just my point.  It is very possible to get 1600 cps with a 12.2
  2487. connection.  At 14.4 you should be getting closer to 1800 cps.  Another factor
  2488. which can affect your cps is the type of computer and quality of phone lines.
  2489. The CPS can only give you an approx value.  Also, how do you know that it is
  2490. correctly calculating the CPS value.  Is it counting the actually bits or is it
  2491. calculating the value by assuming a non-error correction connection.
  2492.  
  2493. As far as other people not having problems and you are so thus it must be a
  2494. problem with your particular modem, that is an incorrect assumption.  The
  2495. problems you are having are very consistant with line noise.  
  2496.  
  2497. Mark - Supra Tech Support
  2498.  
  2499.  
  2500. Msg#:  334 *MODEM*
  2501. 05-31-92 12:19:22
  2502. From: JAMES HUSSIERE
  2503.   To: SYSOP (Rcvd)
  2504. Subj: TEST MODE
  2505. Hello. I am a proud owner of a SupraFAXModem v32.bis, but I seem to be having a
  2506. few problems. I won't go into the ones already mentioned, but I do have one
  2507. that I haven't seen anyone else complain about.  Occassionally the modem throws
  2508. itself into a test mode (the display reads "TE") during a transfer.  I have no
  2509. clue if I'm sending something, or what.  Also, my serial number is 900001,
  2510. which I have been told is the same serial number of several of the first models
  2511. released.  Does this make a difference in my modem revision?
  2512.  
  2513. (I know, this sounds confusing.)
  2514.  
  2515. Later... James Hussiere
  2516.  
  2517. (And yes, my registration cardd has been sent in.)
  2518.  
  2519.  
  2520.  
  2521. Msg#:  349 *MODEM*
  2522. 05-31-92 23:58:23
  2523. From: MARK WHITE
  2524.   To: JAMES HUSSIERE (Rcvd)
  2525. Subj: REPLY TO MSG# 334 (TEST MODE)
  2526. TE means "Transmit Error", you had some line hits during your transmission.  If
  2527. you are trying to find out what rev of the ROMs you have, do an AT I3[CR}.
  2528.  
  2529.  
  2530. Msg#:  399 *MODEM*
  2531. 06-02-92 15:28:51
  2532. From: JAMES HUSSIERE
  2533.   To: MARK WHITE (Rcvd)
  2534. Subj: REPLY TO MSG# 349 (TEST MODE)
  2535. Thanks... I guess I was confused.  Is there any way of clearing the "TE" while
  2536. still on-line, salvaging the download, or do I need to hang up and start all
  2537. over?
  2538.  
  2539. I'll also look at the rom revision...
  2540.  
  2541.  
  2542. Msg#:  400 *MODEM*
  2543. 06-02-92 15:39:20
  2544. From: JAMES HUSSIERE
  2545.   To: JAMES HUSSIERE (Rcvd)
  2546. Subj: REPLY TO MSG# 334 (TEST MODE)
  2547. Just got the ROM revision number... looks like it's an early one....
  2548.  
  2549. V1.000-C TR14-Jxxx-001 110
  2550.  
  2551. Or something like that.
  2552.  
  2553. Later...
  2554.  
  2555.  
  2556. Msg#:  462 *MODEM*
  2557. 06-04-92 09:51:33
  2558. From: MARK WHITE
  2559.   To: JAMES HUSSIERE (Rcvd)
  2560. Subj: REPLY TO MSG# 399 (TEST MODE)
  2561. No, you can not clear the TE from the display.  Once the modem stops receiving
  2562. an error, it will clear the TE from display.
  2563.  
  2564.  
  2565. Msg#:  693 *MODEM*
  2566. 06-12-92 09:17:56
  2567. From: SYSOP
  2568.   To: JAMES HUSSIERE (Rcvd)
  2569. Subj: REPLY TO MSG# 399 (TEST MODE)
  2570. The best solution is to step the modem down to a slower speed before dialing
  2571. numbers where you encounter transmit or receive errors.  The command to set to
  2572. 9600 bps is AT N S37=9.  The new ROMs will automate this by initiating fall
  2573. back under noisy line conditions. [Nathan]  Supra Technical Support
  2574.  
  2575.  
  2576. Msg#:  889 *MODEM*
  2577. 06-16-92 17:25:08
  2578. From: JAMES HUSSIERE
  2579.   To: SYSOP (Rcvd)
  2580. Subj: REPLY TO MSG# 693 (TEST MODE)
  2581. Thanks for the advise... it does seem kind of inconveniant to force a baud
  2582. change off line, but I'm very glad to hear that the new ROMs will (hopefully)
  2583. take care of my problems.
  2584.  
  2585. (Actually, I haven't had any trouble lately with transmit errors.)
  2586.  
  2587. I've sent in my warrenty card, but just in case... my address is:
  2588.  
  2589. James A. Hussiere, Star Route Box 160, Poland Spring, ME 04274
  2590.  
  2591. I actually live in New York, but I'm moving soon, and all of my mail can best
  2592. reach me at the Maine address.
  2593.  
  2594. The only other comment I have is my inability to log into certain Dual Standard
  2595. modems.  Not all,but most.  Probably due to configuration problems on their
  2596. end, but what puzzles me is that a friend of mine with a faster Amiga (a 3000
  2597. compaired to my 500) has NO problems connecting to the same HST Dual
  2598. Standard's.  Am I to believe that a faster CPU would also help me?
  2599.  
  2600. Again, thank you for your help. James.
  2601.  
  2602.  
  2603. Msg#:  363 *MODEM*
  2604. 06-01-92 22:43:44
  2605. From: STEVE PEPIN
  2606.   To: TECH SUPPORT
  2607. Subj: LOCK UP
  2608. My problem is similar to msg #103with regards to the modem hanging.  I
  2609. regularly dial in to the GIF Shoppe in Burbank, Ca. I just bought a Supra
  2610. V.32bis modem and am generally happy with it.  The problem is when I log on to
  2611. a BBS at high speed (57600) everything is O.K. until I download.  The D/L works
  2612. fine, but when it's over, I can't do ANYTHING!  The modem doesn't send any data
  2613. at all!  All I can do is REBOOT.  I read the reply to msg #103 regarding an
  2614. upgrade available in a few weeks, that was 5/25/92, I believe.  Will I receive
  2615. that upgrade automatically, or do I have to request it personally?  Also, do I
  2616. need a 16550 UART I/O card to take full advantage of the V.32bis modem?  I have
  2617. a 486/33 AMI BABY VOYAGER motherboard which has the I/O on the M/Board which is
  2618. controlled through the VLSI chipset.  I am told by AMI thatit is a standard COM
  2619. port. With this processor speed, do I need to add a 16550 card?
  2620.  
  2621.  
  2622. Msg#:  368 *MODEM*
  2623. 06-02-92 03:32:48
  2624. From: AL BLACKBURN
  2625.   To: ROBERT OTTKE
  2626. Subj: SUPRAFAX MODEM
  2627. Please put me on that upgrade list also...6703 La Salle St Tacoma Wash  
  2628. 98499....
  2629.  
  2630.  
  2631. Msg#:  452 *MODEM*
  2632. 06-03-92 20:49:51
  2633. From: BOB SHATTLER
  2634.   To: ROBERT OTTKE
  2635. Subj: REPLY TO MSG# 368 (SUPRAFAX MODEM)
  2636. What is this new ROM update about?  I have the Supra Fax v32bis 14400.  If
  2637. there is a ROM update for this modem what does it fix & how do I get it?
  2638.  
  2639.  
  2640. Msg#:  569 *MODEM*
  2641. 06-08-92 12:48:10
  2642. From: JAN WILSON
  2643.   To: ROBERT OTTKE
  2644. Subj: REPLY TO MSG# 452 (SUPRAFAX MODEM)
  2645. I was looking for the WINSUPRA.ZIP file to fix the transmission bug in the use
  2646. of WinFax with the SupraFaxModem v.32bis. Do I understand you need a rom
  2647. upgrade? If so please put me on the list. If not, where can I find the file?
  2648. BTW, modem works great with Procomm Plus for Windows!
  2649. -- Jan Wilson, 2514 Palm Place Dr NE, Palm Bay, FL 32905-3965, (407) 984-5238
  2650. (voice) 728-2763 (fax, standalone).
  2651.  
  2652.  
  2653. Msg#:  586 *MODEM*
  2654. 06-08-92 22:03:26
  2655. From: PROTEUS
  2656.   To: JAN WILSON
  2657. Subj: REPLY TO MSG# 569 (SUPRAFAX MODEM)
  2658. Hi JaIhave been unable to get my supra v.32bis to work properly iwith Procomm
  2659. for Windows.  Any suggestions?  I'm getting usaruart overruns and crc
  2660. errors...Help!!!
  2661.  
  2662.  
  2663.  
  2664.  
  2665. Msg#:  371 *MODEM*
  2666. 06-02-92 07:17:16
  2667. From: JOHN BUNGARD
  2668.   To: MARK WHITE (Rcvd)
  2669. Subj: NEW ROM FOR 32BIS
  2670. Please put me on list for ROM upgrade for 32BIS modem My address is 8570 Katy
  2671. Fwy. # 116, Houston, Tx. 77024. My serial number of modem is 000858.
  2672.  
  2673.  
  2674.  
  2675. Msg#:  378 *MODEM*
  2676. 06-02-92 08:31:41
  2677. From: SYSOP
  2678.   To: JIMMER (Rcvd)
  2679. Subj: UPGRADE
  2680. The upgrade addresses two issues: 1) It has a permanent fix for people having
  2681. problems with Winfax, especially with sending.  2) It allows the modem to send
  2682. the initialization signal for fallback.  It currently will fall back, but waits
  2683. for the signal.   [Nathan]  Supra Technical Support
  2684.  
  2685.  
  2686. Msg#:  382 *MODEM*
  2687. 06-02-92 08:45:51
  2688. From: SYSOP
  2689.   To: DUANE DAVIS
  2690. Subj: MODEM ORDER
  2691. Duane,  Your modem will be shipped by the end of this week, or next week.
  2692. Sorry for the delay.
  2693.  
  2694.  
  2695. Msg#:  384 *MODEM*
  2696. 06-02-92 08:54:54
  2697. From: SYSOP
  2698.   To: PAUL THEODOROPOULOS (Rcvd)
  2699. Subj: PROBLEMS WITH MY V32/BIS
  2700. Paul, I am still puzzled as to why you can not log on here at at least 4800.
  2701. If it works well on most other boards, then I will attribute this to our noisy
  2702. lines.Let me know if you have any problems, or if you have any more questions. 
  2703. [Nathan]  Supra Techncial Support
  2704.  
  2705.  
  2706. Msg#:  407 *MODEM*
  2707. 06-02-92 18:53:28
  2708. From: MICHAEL L. LEE
  2709.   To: SYSOP (Rcvd)
  2710. Subj: CONNECTION AT 144
  2711. Hello!  I just recently received my Supra v.32bis and this is the first chane
  2712. Ihad to try connecting on your BBS at 144.  Everything seems to be working just
  2713. fine ( te full screen editor of this bbs is a little hard to get used to).I
  2714. tried connecting to the Qualitas BBS here in Washington, DC tonight and had
  2715. some trouble maintaining a 144 connection when I downloaded some messges.  I'm
  2716. using Qmodem 5.1 and had the software set up for a connection at 57600 and got
  2717. some line noise.   The subsequent downloadaafaile  anThe subsequent download
  2718. failed and when I reconnected at 9600 (software) 144 on the modem every thing
  2719. workd fine.  I think it was a combination of getting the software settings
  2720. right and then letting the modem do its job.  So far I think the Supra v.32bis
  2721. is a fine piece of equipment.  So long......
  2722.  
  2723. Mike PS...Ijust looked at the help screen so please forgive the messed up text
  2724. in this message.
  2725.  
  2726.  
  2727. Msg#:  806 *MODEM*
  2728. 06-15-92 09:16:22
  2729. From: SYSOP
  2730.   To: MICHAEL L. LEE (Rcvd)
  2731. Subj: REPLY TO MSG# 407 (CONNECTION AT 144)
  2732. Granted, this editor does take a little getting used to.  Try setting your
  2733. software to 19,200.  If you get good results with that, then try 38,400, etc. 
  2734. [Nathan]  Supra Tehnical Support
  2735.  
  2736.  
  2737. Msg#:  882 *MODEM*
  2738. 06-16-92 12:12:56
  2739. From: MICHAEL L. LEE
  2740.   To: SYSOP (Rcvd)
  2741. Subj: REPLY TO MSG# 806 (CONNECTION AT 144)
  2742. Thanks for the advice!  I'm using Unicom 3.0 at the moment with the software
  2743. set to 19200.  It looks like a good connection.  Do you know if any one from
  2744. Supra Sales has read my message about coming to washington dc to make a
  2745. presentation to the Capital Area SysOps group?  There is quite a bit of
  2746. interest in Supra's V.32bis modem and would be a great forum to promote your
  2747. modem for serious BBS usage.  Take care, talk to you later.....
  2748.  
  2749.  
  2750.  
  2751. Msg#: 1179 *MODEM*
  2752. 06-24-92 10:03:33
  2753. From: SYSOP
  2754.   To: MICHAEL L. LEE (Rcvd)
  2755. Subj: REPLY TO MSG# 882 (CONNECTION AT 144)
  2756. I have left the message with the Sales Manager.  He is out of town right now,
  2757. but he will get your message. [Nathan]  Supra Technical Support
  2758.  
  2759.  
  2760. Msg#: 1215 *MODEM*
  2761. 06-25-92 04:47:56
  2762. From: MICHAEL L. LEE
  2763.   To: SYSOP
  2764. Subj: REPLY TO MSG# 1179 (CONNECTION AT 144)
  2765. Good morning!  Look forward to hearing from your sales manager.  Have a
  2766. successful day!  Talk to you later......  PS: My office phone # is
  2767. 202-267-3321/ home 703-791-5281 just in case the sales manager requires a
  2768. number to get in touch with me.   Mike
  2769.  
  2770.  
  2771. Msg#:  411 *MODEM*
  2772. 06-02-92 22:24:53
  2773. From: STEVE PEPIN
  2774.   To: SYSOP (Rcvd)
  2775. Subj: WELL?
  2776. I placed a message on the modem board and apparently it hasn't been read yet.
  2777. I still can't download at 57600 without locking up following the download.  Any
  2778. suggestions?
  2779.  
  2780. bye for now...
  2781.  
  2782.  
  2783. Msg#:  527 *MODEM*
  2784. 06-06-92 22:00:44
  2785. From: BRIAN DHATT
  2786.   To: STEVE PEPIN (Rcvd)
  2787. Subj: REPLY TO MSG# 411 (WELL?)
  2788. If you have to reboot, then the problem is not in the modem but rather in the
  2789. software you are using.  Your modem can not lock up your computer, and a reboot
  2790. would not reset your modem either.
  2791.  
  2792.  
  2793. Msg#:  776 *MODEM*
  2794. 06-14-92 14:34:24
  2795. From: STEVE PEPIN
  2796.   To: BRIAN DHATT (Rcvd)
  2797. Subj: REPLY TO MSG# 527 (WELL?)
  2798. You're right! I found out that the comm. prg. (QL2FAX) is no good with error
  2799. correcting protocols such as zmode, etc. I'm using QMODEM now with no problems.
  2800.  
  2801.  
  2802. Msg#:  420 *MODEM*
  2803. 06-03-92 06:50:01
  2804. From: KERRY COLE
  2805.   To: TECH SUPPORT
  2806. Subj: S40 & SUPRA<->SUPRA
  2807.  
  2808. 1. When I do a ATs40? I show 87 as the value, the book says 55 is the default
  2809. settings.  I am using the default settings.  Which is right? 2.  When I do a
  2810. AT\G0 S40 increases by 128.  No matter if I do another \G0-or- \G1, it remains
  2811. the same.  This must be a bug.  The only way I can change S40 is with adirect
  2812. write to the register.  Is this a bug?? 3.  I cannot connect with ANOTHER
  2813. Supra.  Is this a bug??
  2814.  
  2815.  
  2816.  
  2817.  
  2818.  
  2819. Msg#:  422 *MODEM*
  2820. 06-03-92 10:01:21
  2821. From: JIMMER
  2822.   To: SYSOP (Rcvd)
  2823. Subj: ROM UPGRADE
  2824. Can you put me on the list for the ROM upgrade when it starts shipping? SN
  2825. 000934 Jim Delton 8630 S. Holbrook Tempe, Az 85284
  2826.   
  2827. Thanks
  2828.  
  2829.  
  2830. Msg#:  813 *MODEM*
  2831. 06-15-92 09:36:36
  2832. From: SYSOP
  2833.   To: JIMMER (Rcvd)
  2834. Subj: REPLY TO MSG# 422 (ROM UPGRADE)
  2835. You will receive the new chip soon. Supra Technical Support
  2836.  
  2837.  
  2838. Msg#:  902 *MODEM*
  2839. 06-17-92 07:51:17
  2840. From: JIMMER
  2841.   To: SYSOP
  2842. Subj: REPLY TO MSG# 813 (ROM UPGRADE)
  2843. Thanks.   I'll be watching for it.  I'm pretty satisfied with the modem in
  2844. spite of some of the problems that have popped up.  Supra miss-stepped in
  2845. getting ready for the onslaught of IBM-PC types when they failed to have this
  2846. BBS fully functioning before the modem hit the market.  I don't envy the
  2847. position tech support has been in.  Will the new ROM effectively replace ALL
  2848. the controlling parameters for the modem?  Or are the other chips that remain
  2849. that do something more then power conditining?
  2850.  
  2851.  
  2852. Msg#:  425 *MODEM*
  2853. 06-03-92 11:42:46
  2854. From: JIM HEBERT
  2855.   To: SYSOP (Rcvd)
  2856. Subj: V.32BIS BUGS
  2857. Reporting the following bugs: 
  2858.  
  2859. 1)  Give the modem command ATA(CR)
  2860.     The modem will evenutally negotiate a 300 baud connection with dial tone!
  2861. In some cases it disconnects shortly after reporting "Connect 300" on the
  2862. serialport and showing "CD" and "3" in the display. Other times it hangs in
  2863. there with its dialtone partner for quite a while. This has occurred with both
  2864. modems (first was returned because Cust. Ser. said this was a defect...)  This
  2865. is a problem in use as a server/host because wrong  numbers or hang-ups produce
  2866. "connect" reports and start sessions on the server... 
  2867.  
  2868. 2)  Modem does not negotiate with Telebit T-1000 when answering. It negotiates
  2869. with Telebits when the Supra is the calling modem, but will not negotiate with
  2870. Telebit T-1000 when Supra is the answering modem. I realize that, given the
  2871. incredible number of settings for the Telebit, the problem may lie in the
  2872. T-1000, but the settings used permit it to connect to many other v.22bis
  2873. modems. It will not connect v.22bis with the Supra.   
  2874.  
  2875. Other than these, I have not had a problem with the modem.  I have seen it
  2876. transfer a file at 14,400 /v.42bis with a rate of 3,390 cps. This was on a file
  2877. "The_Wave.txt", which is designed, I believe, to exploit the data compression
  2878. capabilities of the v.42bis engine.  The DCE rate was limited to 38,400, so
  2879. this transfer rate is near the maximum expected.  
  2880.  
  2881. Please comment on the connecting-with-dialtone problem, as this is the most
  2882. serious hurdle to me buying any more....
  2883.  
  2884.  
  2885. Msg#:  427 *MODEM*
  2886. 06-03-92 11:53:28
  2887. From: GEOFFREY LI
  2888.   To: SYSOP (Rcvd)
  2889. Subj: LINK MAIL AND PROBLEMS
  2890. Hello,
  2891.  
  2892. I would like to know if it is possible for me to link up all the mail in this
  2893. BBS.  Since I want to build a BBS in HK for Supra technical support, I think it
  2894. is much better if users here can directly send and receive mail from this BBS.
  2895. What kind of program will I need to do that?
  2896.  
  2897. Here are some problem I encountered when using Supra v32bis modem : 1) Bitfax
  2898. v3.07.07 cannot receive fax from other fax modem or fax machines.
  2899.    It can establish the link and receive some of the page.  The top half of
  2900.    each page is always omitted. 2) All AT command with prefix '-' cannot be
  2901. used.  E.g. AT-K1 will make the
  2902.    modem issue error.
  2903.  
  2904. In additional, is there any formal documentation about the fax function of 
  2905. Supra v32bis modem?  I want to develop some programs for it.
  2906.  
  2907. Thank you.
  2908.  
  2909. Regards, Geoffrey LI
  2910.  
  2911.  
  2912.  
  2913. Msg#:  443 *MODEM*
  2914. 06-03-92 13:25:45
  2915. From: DARREK KAY
  2916.   To: SYSOP (Rcvd)
  2917. Subj: WINFAX & 14.4
  2918. How do you make WinFAX Pro use the 14.4 FAX send option?  That's one of the
  2919. reasons I bought the SupraFAXModem for in the first place!
  2920.  
  2921. Darrek Kay kayd@prism.cs.orst.edu (503)737-9410
  2922.  
  2923.  
  2924. Msg#:  447 *MODEM*
  2925. 06-03-92 18:44:41
  2926. From: BRIAN EARGLE
  2927.   To: SYSOP (Rcvd)
  2928. Subj: SYSOP'S DEAL
  2929. How long does it usually take to get a V32bis Modem with the sysops deal? I he
  2930. .
  2931.  
  2932.  
  2933. Msg#:  824 *MODEM*
  2934. 06-15-92 11:07:19
  2935. From: SYSOP
  2936.   To: BRIAN EARGLE
  2937. Subj: REPLY TO MSG# 447 (SYSOP'S DEAL)
  2938. Brian, It takes about a monthat the most, including the time it takes us to
  2939. verify your account. Supra Technical support
  2940.  
  2941.  
  2942. Msg#:  458 *MODEM*
  2943. 06-03-92 22:08:04
  2944. From: STEVE DRESSLER
  2945.   To: JIMMER (Rcvd)
  2946. Subj: ...
  2947. Mr. Jummer,
  2948.  
  2949.  I have a friend of mine that lives in Tempe, he just got a new SupraFax 14400,
  2950. you might know him if you run a board or run around on other boards up there.
  2951. His name is Chris Houg. If you would, leave him a message in Tempe and ask him
  2952. to boot up dbridge and poll BitStream in Tulsa Fido 1:170/604
  2953.  
  2954.  Thanks
  2955.  
  2956.  
  2957. Msg#:  488 *MODEM*
  2958. 06-05-92 14:50:01
  2959. From: JIMMER
  2960.   To: STEVE DRESSLER (Rcvd)
  2961. Subj: REPLY TO MSG# 458 (...)
  2962. I've been on quite a few BBS in town but don't recall the name of Chris Houg.
  2963. Of course he may be using a handle.  I'll pass the message on if I see his name
  2964. pop up.
  2965.  
  2966.  
  2967. Msg#:  460 *MODEM*
  2968. 06-04-92 00:17:08
  2969. From: DAN GALPIN
  2970.   To: ALL
  2971. Subj: SUPRA V.32BIS QUESTIONS/PROBLEMS
  2972. I have been having some problems with my brand new Supra, and am wondering if
  2973. these are "normal" or not.
  2974. . Using ATS37=ANYTHING will not force the modem to connect at that speed. I was
  2975. only able to connect here because the modem correctly retrained to 12.0 k
  2976. fallback. Bulletin Boards where the line quality is too lousy for 14.4
  2977. connections cannot be called as the modem will not usually retrain. I have
  2978. never seen the modem connect to another v.32bis modem at anything other than
  2979. 14.4 and 12.0 no matter how the modem was set with ATS37.
  2980. . Using +++ to place the modem into command mode seems to cause the modem to
  2981. drop carrier. I have had this explained as "the other modem is causing the
  2982. carrier drop" but the modem from another manufacturer a friend of mind has does
  2983. not exhibit this behavior connected to the same system. Perhaps the ROMs in
  2984. that modem inhibit the final + when it is sent into command mode keeping it
  2985. from happening. (This is pure speculation),. it is annoying to try to check the
  2986. line level and get a rousing NO CARRIER message.
  2987. . Other than these problems the modem seems to be fine. It cannot connect if
  2988. the line level is too noisy right now... because it always will try at 14.4.
  2989. . Help.  
  2990. -Dan
  2991.  
  2992.  
  2993. Msg#:  466 *MODEM*
  2994. 06-04-92 12:40:08
  2995. From: MICHAEL L. LEE
  2996.   To: DAN GALPIN (Rcvd)
  2997. Subj: REPLY TO MSG# 460 (SUPRA V.32BIS QUESTIONS/PROBLEMS)
  2998. Hello, Dan.  I'm not sure that I cna help, but let me relate an experience I
  2999. had a couple of nights ago...I connected to a local board tthat has a high
  3000. speed modem.  I set my comm program for 57600 DCE and teh modem connected at
  3001. 1400 and then I notice screen distortion, the kind you get with line noise.  I
  3002. attempted a download using zmodem and lost the connection.  I change the DCE
  3003. speed to 38400 and reconnected.  Stile got the screen distortion and again lost
  3004. the zmodem download.  I changed the DCE to 9600 and reconnected...no problems.
  3005. Each time I connected though, the supra v.32bis connected at 14400. You might
  3006. try different DCE sttings to see if you get a better connection.  I just use
  3007. the factory recommended settings AT&F2.  This setting workd finr for me.  Also
  3008. some comm programs handle highspeed modems better than others.  Good luck....
  3009.  
  3010.  
  3011.  
  3012. Msg#:  479 *MODEM*
  3013. 06-05-92 00:35:44
  3014. From: DAN GALPIN
  3015.   To: DAN GALPIN (Rcvd)
  3016. Subj: REPLY TO MSG# 460 (SUPRA V.32BIS QUESTIONS/PROBLEMS)
  3017. Okay.. I realized that I may have not set atN to force the connection..
  3018. However, why does +++ always hang the modem?
  3019.  
  3020.  
  3021. Msg#:  528 *MODEM*
  3022. 06-06-92 22:04:12
  3023. From: BRIAN DHATT
  3024.   To: DAN GALPIN
  3025. Subj: REPLY TO MSG# 460 (SUPRA V.32BIS QUESTIONS/PROBLEMS)
  3026. In addition to AT S37=<number>, you must issue a AT N.  
  3027.  
  3028.  
  3029. Msg#:  461 *MODEM*
  3030. 06-04-92 09:12:34
  3031. From: JOHN HAUNTON
  3032.   To: SYSOP (Rcvd)
  3033. Subj: V.32BIS FAXMODEM
  3034. Help!  I cannot use the modem as a FAX, my software (BITFAX) reports that there
  3035. is no response from the modem.   I understand there is a fix (new EEPROM?) for
  3036. this problem.  Please send one to: Mr John Haunton, Polymer Laboratories Ltd,
  3037. The Technology Centre, Epinal Way, Loughborough, LEICS, L11 0QE, UK. As soon as
  3038. possible please.  I have also had a large amount of trouble trying to achive
  3039. reliable comms at more than 2400 baud between UK and USA.  Do you have any
  3040. experiance /suggestions for me.
  3041.  
  3042.  
  3043. Msg#:  826 *MODEM*
  3044. 06-15-92 11:26:52
  3045. From: SYSOP
  3046.   To: JOHN HAUNTON
  3047. Subj: REPLY TO MSG# 461 (V.32BIS FAXMODEM)
  3048. John, I'll make sure that you receive the new ROM chips soon.  I haven't heard
  3049. of problems connecting overseas above 2400.  You need to set the modem to the
  3050. speed of the remote modem before you dial the number.  This cuts down on the
  3051. connect negotiation time.  If you're calling a 9600 bps modem, type (AT N S9).
  3052. OOOps! that is (AT N S37=9).  (Refer to the table on page 53 of the Reference
  3053. Manual).  If you have any more questions, please let me know. [Nathan]  Supra
  3054. Technical Support
  3055.  
  3056.  
  3057. Msg#:  465 *MODEM*
  3058. 06-04-92 11:57:54
  3059. From: H>     D       D       DZW
  3060.   To: SUPRA TECHNICAL SUPPORT
  3061. Subj: FAXING W
  3062. I screwed up my subject.
  3063.  
  3064. I cannot get my v.32bis to send faxes with delrina winfax pro 2.0 i tried
  3065. downloading the winfax pro file from your bbs. Neither of the options (replace
  3066. mod file or send class I) worked for me. Do I have any other options?? My Name
  3067. is Mark A. Horton 629 Eastview Dr. Madison, Alabama 35758 (205) 876-5651 (205)
  3068. 461-7584 (answering machine) Thanks
  3069.  
  3070.  
  3071.  
  3072.  
  3073.  
  3074. Msg#:  467 *MODEM*
  3075. 06-04-92 12:56:24
  3076. From: ANDY STAHOWIAK
  3077.   To: SYSOP (Rcvd)
  3078. Subj: CLICKING
  3079. What command will stop the clicking or cycling? When I enter atdtxxxxxx it
  3080. picksup and I can hear the modem clicking or cycling back and forth?
  3081. Thanks...Andy
  3082.  
  3083.  
  3084. Msg#:  827 *MODEM*
  3085. 06-15-92 11:29:47
  3086. From: SYSOP
  3087.   To: ANDY STAHOWIAK (Rcvd)
  3088. Subj: REPLY TO MSG# 467 (CLICKING)
  3089. Andy, Does the modem dial and connect ok?  When it dials, there is a selenoid
  3090. that clicks when it goes off hook, etc.  Is that click interfering with
  3091. something?  If its dialing and connecting fine, I wouldn't worry about it. 
  3092. [Nathan]  supra Technical support
  3093.  
  3094.  
  3095. Msg#:  850 *MODEM*
  3096. 06-16-92 01:50:32
  3097. From: ANDY STAHOWIAK
  3098.   To: SYSOP (Rcvd)
  3099. Subj: REPLY TO MSG# 827 (CLICKING)
  3100. Well, I guess it was my nram settings,everything a ok! just waiting for rom
  3101. updrade in july.....Thanks!! For an afforable high speed modem! Andy
  3102.  
  3103.  
  3104. Msg#: 1175 *MODEM*
  3105. 06-24-92 09:56:15
  3106. From: SYSOP
  3107.   To: ANDY STAHOWIAK (Rcvd)
  3108. Subj: REPLY TO MSG# 850 (CLICKING)
  3109. Glad you like it. sysop
  3110.  
  3111.  
  3112. Msg#:  468 *MODEM*
  3113. 06-04-92 13:10:57
  3114. From: DENVER ATWOOD
  3115.   To: SYSOP (Rcvd)
  3116. Subj: ROM UPGRADE
  3117. I have a SUPRA V.32bis serial number 14E 002265.  I have sent in my
  3118. registration card and would like the ROM upgrade.  My address is 5022 Mountain
  3119. View Parkway, Birmingham, AL 35244.  I have experienced the difficulty
  3120. connecting to other SUPRA's at greater than 9600, but I am generally pleased
  3121. with your product.  Thanks you. [A
  3122.  
  3123.  
  3124. Msg#:  828 *MODEM*
  3125. 06-15-92 11:32:29
  3126. From: SYSOP
  3127.   To: DENVER ATWOOD (Rcvd)
  3128. Subj: REPLY TO MSG# 468 (ROM UPGRADE)
  3129. Denver, We'll send you the new ROMs very soon.  It will help connecting with
  3130. other Supra's by initiating fall back.  Please let me know if you have any more
  3131. questions. [Nathan]  Supra Technical Support
  3132.  
  3133.  
  3134. Msg#:  852 *MODEM*
  3135. 06-16-92 05:57:44
  3136. From: DENVER ATWOOD
  3137.   To: SYSOP (Rcvd)
  3138. Subj: REPLY TO MSG# 828 (ROM UPGRADE)
  3139. Thank you.  By the way, I have been using QLII for faxing and it seems that all
  3140. my outgoing faxes are reduced in size.  Is this a function of the software or
  3141. the modem?  Will a ROM upgrade fix it if the modem is the problem?  Otherwise I
  3142. have been very satisfied with my SUPRA.
  3143.  
  3144.  
  3145. Msg#: 1176 *MODEM*
  3146. 06-24-92 09:57:38
  3147. From: SYSOP
  3148.   To: DENVER ATWOOD
  3149. Subj: REPLY TO MSG# 852 (ROM UPGRADE)
  3150. Make sure that in the configuration of the software, you have not selected
  3151. compress text.  It might need the latest ROM chips, which will be sent out in
  3152. mid-July. [Nathan]  Supra Technical Support
  3153.  
  3154.  
  3155. Msg#:  469 *MODEM*
  3156. 06-04-92 13:36:22
  3157. From: PAUL MENARD
  3158.   To: SYSOP (Rcvd)
  3159. Subj: MODEM
  3160. I will give them a call. Thanks.
  3161.  
  3162.  
  3163. Msg#:  470 *MODEM*
  3164. 06-04-92 14:02:26
  3165. From: RICHARD SAVAGE
  3166.   To: SYSOP (Rcvd)
  3167. Subj: SUPRA V32BIS UPDATES
  3168. HAS SUPRA DONE ANY UPDATES OF ROM CONCERNING FALL-FORWARD FALL-BACK FOR MODEMS.
  3169. I AM REGISTERED AND IF I HAVE TO GET ON WAITING LIST PLS DO SO NOW. ANY
  3170. SETTINGS WOULD BE APPREC. TNX
  3171.  
  3172.  
  3173. Msg#:  831 *MODEM*
  3174. 06-15-92 11:38:56
  3175. From: SYSOP
  3176.   To: RICHARD SAVAGE (Rcvd)
  3177. Subj: REPLY TO MSG# 470 (SUPRA V32BIS UPDATES)
  3178. Richard, We will be sending out a ROM uprade which enables the Supra modem to
  3179. initiate fall back.  It will be sent out in mid-July to all registered owners,
  3180. free of charge.  If you would like to give me your address, I will make sure
  3181. that they are sent out to you ASAP. [Nathan]  Supra Technical Support
  3182.  
  3183.  
  3184. Msg#:  881 *MODEM*
  3185. 06-16-92 11:59:05
  3186. From: RICK LOVDAHL
  3187.   To: SYSOP (Rcvd)
  3188. Subj: REPLY TO MSG# 831 (SUPRA V32BIS UPDATES)
  3189. I sent in my warranty ca  but just in case, here's my particulars:
  3190.  
  3191. Richard H. Lovdahl - Lovdahl & Associates 330 Molino Avenue Long Beach, CA
  3192. 90814-2341 (310) 433-8376 voice & fax SupraFAX modem v.32bis   SN# 14E 004784 
  3193. Thanks ...  Rick
  3194.  
  3195.  
  3196.  
  3197.  
  3198.  
  3199. Msg#: 1178 *MODEM*
  3200. 06-24-92 10:01:29
  3201. From: SYSOP
  3202.   To: RICK LOVDAHL
  3203. Subj: REPLY TO MSG# 881 (SUPRA V32BIS UPDATES)
  3204. OK.  Your on the list to receive the new ROM chips. Supra Technical Support
  3205.  
  3206.  
  3207. Msg#:  476 *MODEM*
  3208. 06-04-92 21:52:33
  3209. From: BERNARD JOHNSON
  3210.   To: SYSOP (Rcvd)
  3211. Subj: ROM UPGRADES
  3212. I called the tech supp
  3213.  
  3214. I cale I called the tech support t line over a month ago and 2 of the three
  3215. people I talked to refused to believe the problem with random "crashing" and
  3216. the third FINALLY agreed to send me new roms to fix the crashing.  I think it
  3217. is quite disrespectful to customers to not followup.  I have already
  3218. recommended several friends to NOT buy supra modems because of poor customer
  3219. relations.  We are about to buy a new modem at work also I I recommended
  3220. another brand to them also.
  3221.  
  3222. I would still appreciate my ROMS though.  I'm just tired of makeing phone calls
  3223. for no reason.  I sent in my registration card so you can find my address
  3224. there.  Maybe you can be more useful than the others I have talked to.
  3225.  
  3226. Thanks, Bernard Johnson
  3227.  
  3228.  
  3229.  
  3230.  
  3231. Msg#:  834 *MODEM*
  3232. 06-15-92 11:50:35
  3233. From: SYSOP
  3234.   To: BERNARD JOHNSON
  3235. Subj: REPLY TO MSG# 476 (ROM UPGRADES)
  3236. Mr. Johnson, I apologize for the problems you have had in dealing with
  3237. Technical Support.  We do our best to provide good service.  Did you receive
  3238. the new ROM chips?  If not, please leave another message here with your
  3239. address, and I'll be sure that you get them.  If you would like a quicker
  3240. solution, please call our Tech Support line, explain the situation, and ask for
  3241. an exchange.  If you have any more questions, please let me know. [Nathan]
  3242. Supra Technical Support
  3243.  
  3244.  
  3245. Msg#:  480 *MODEM*
  3246. 06-05-92 00:39:03
  3247. From: DAN GALPIN
  3248.   To: TECH SUPPORT
  3249. Subj: COMMAND MODE
  3250. Why does command mode (+++) cause the modem to disconnect? (even from this BBS)
  3251. is something wrong? Is there a setting I must change? Is it my term software?
  3252. . Also, what ROM upgrades will be offered.. when? and approx. how much? (I have
  3253. ROM revision E. Is this the newest?)
  3254. .
  3255. -Dan
  3256.  
  3257.  
  3258. Msg#:  484 *MODEM*
  3259. 06-05-92 07:14:24
  3260. From: DONALD WATSON
  3261.   To: SYSOP (Rcvd)
  3262. Subj: PULSE DIAL PROBLEMS
  3263. This is the 5th time I write you this message. I got three answers, but they
  3264. were nonsense. I hope for your real help this time ! Now, my problem is as
  3265. follows: My new SupraFAXModem V32bis doesn't disconnect the phone, which i
  3266. connected to the phone's plug of the modem, while it is dialing in pulse mode.
  3267. While dialing in tone modem, the phone is correctly disconnected. This is not a
  3268. bug in my term software, as you meen! Please try it yourself. Neary every other
  3269. modem I know disconnects the phone, when the modem goes on hook state. Why
  3270. doesn't supra do that, when dialing in pulse mode. Is this a hardware bug or a
  3271. software bug? Will it be removed in the next ROM update, when ever it comes? 
  3272. Please try the problem by yourself and you will find that it is the modem,
  3273. which doesn't work correct while pulse dialing!!! Thanks for your answer.
  3274.  
  3275.  
  3276. Msg#:  855 *MODEM*
  3277. 06-16-92 08:21:26
  3278. From: SYSOP
  3279.   To: DONALD WATSON (Rcvd)
  3280. Subj: REPLY TO MSG# 484 (PULSE DIAL PROBLEMS)
  3281. Donald, I apologize for any ambiguity.  There is a problem with your modem.
  3282. You need to contact our Technical Support number at (503) 967-2440, or write or
  3283. FAX me your phone number, or leave it here.  If you get me your number, I will
  3284. be glad to call you.  We will get a fix for this problem promptly.  If you have
  3285. any more questions, please let me know. [Nathan]  Supra Technical Support
  3286.  
  3287.  
  3288. Msg#:  901 *MODEM*
  3289. 06-17-92 04:52:03
  3290. From: DONALD WATSON
  3291.   To: SYSOP
  3292. Subj: REPLY TO MSG# 855 (PULSE DIAL PROBLEMS)
  3293. OK, here is my telephone number: +49 821 664265 Please note that I call from
  3294. germany. Our time is 9 hours forward to your time! I would be glad to get your
  3295. calling, soon. Thanks.
  3296.  
  3297.  
  3298. Msg#:  490 *MODEM*
  3299. 06-05-92 18:35:59
  3300. From: KIRK BLUM
  3301.   To: SYSOP (Rcvd)
  3302. Subj: ROM UPGRADE LIST
  3303. Hello,  I left a previous message that I now realize was a reply to Chuck (?)
  3304. and I am not sure if you noticed it.  I just got my v.32bis (after waiting
  3305. since Jan.) and I would like to get on the upgrade list.  The strange thing
  3306. about my new modem is that it is serial # 14e900001 which I understand is a
  3307. really early one.  Are there any known problems (other than the bugs that the
  3308. ROM upgrade should fix) that this particular piece of hardware has??  I have
  3309. had a number of strange occurances such as a really whacky attempts to log on
  3310. here (it would change speeds a number of times all the way to 300 baud before
  3311. setteling at 12000 baud [not 1200, but 1 2 0 0 0!!] but I would get garbage or
  3312. it would not register the connection (TELIX v3.15).  I've also experienced that
  3313. a ^X would hang the modem up (such as after selecting a file to download and
  3314. the other end says to "Start download or press CTRL-X a few times to stop
  3315. transfer").  Also, when I fax the WINFAX PRO sample Fax Cover at 9600 it will
  3316. garbage on the other end (but at 4800 it works but the Supra says FX 96 but the
  3317. FAX machine says 4800! [does WINSUPRA.ZIP have anything to do with that or does
  3318. the fix not apply to the PRO version?!??]) Anyway, again my address for the ROM
  3319. upgrade list is: Kirk Blum 1844 Rosswood Dr. San Jose, CA 95124 VOICE:370-7979
  3320. x 315   MODEM: 370-3139  (these are my work numbers)
  3321.      THX Kirk
  3322.  
  3323.  
  3324. Msg#:  577 *MODEM*
  3325. 06-08-92 18:55:02
  3326. From: KIRK BLUM
  3327.   To: KIRK BLUM (Rcvd)
  3328. Subj: REPLY TO MSG# 490 (ROM UPGRADE LIST)
  3329. Well, I finally managed to connect with my Supra after setting &Q9 and after a
  3330. number of attempts.  It would connect, get the please enter your name prompt
  3331. from the BBS then hang up... truly weird.  Please, please contact me so I can
  3332. get this thing working as well as I can.  I know you guys have to be better
  3333. than USRobotics at this 'cause their stuff is big, ugly, and over-priced (yet
  3334. work well despite other short comings). (BTW: this connection is at 12000 baud
  3335. also.. don't know what this means...)   THX Kirk
  3336.  
  3337.  
  3338. Msg#:  856 *MODEM*
  3339. 06-16-92 08:27:52
  3340. From: SYSOP
  3341.   To: KIRK BLUM
  3342. Subj: REPLY TO MSG# 577 (ROM UPGRADE LIST)
  3343. Kirk, Didn't I talk with you on the phone??  The 12000 connection is because
  3344. the modem on our BBS told yours to drop down due to the noisy lines on our
  3345. system.  The ROM upgrade applies to both Winfax 2.0 and Winfax Pro.  It
  3346. incorporates a fix for problems faxing in class 2.  You're right, for most
  3347. people, FAX problems tend to go away at 4800 bps.  But I don't know why it says
  3348. 9600 on the screen. (??)  I will get those new ROMs sent out to you. [Nathan]
  3349. Supra Technical Support
  3350.  
  3351.  
  3352. Msg#:  496 *MODEM*
  3353. 06-05-92 20:22:03
  3354. From: HARRY BROWN
  3355.   To: SYSOP (Rcvd)
  3356. Subj: SUPRAFAX MODEM
  3357. Hi! I would like to have my name added to the  list for upgrade of Supra Roms 
  3358. for the SupraFax Modem.
  3359.         Harry Brown
  3360.         7137 S. Maplewood
  3361.         Chicago, IL  60629
  3362.  
  3363. Rom Version: V 1.00-C TR14-Jxxx-001 110 Ser# 14E 000087
  3364.  
  3365.  
  3366. Msg#:  860 *MODEM*
  3367. 06-16-92 08:34:31
  3368. From: SYSOP
  3369.   To: HARRY BROWN (Rcvd)
  3370. Subj: REPLY TO MSG# 496 (SUPRAFAX MODEM)
  3371. Harry, You may already have the new ROMs.  When you do an (AT I 3) and it
  3372. responds with V1.200-C, then those are the ones.  Please get back to me. 
  3373. [Nathan]  Supra Technical Support
  3374.  
  3375.  
  3376. Msg#:  893 *MODEM*
  3377. 06-16-92 20:01:13
  3378. From: HARRY BROWN
  3379.   To: SYSOP (Rcvd)
  3380. Subj: REPLY TO MSG# 860 (SUPRAFAX MODEM)
  3381. I gave the
  3382.  AT I3 as you suggested my Rom version is V1.000-C
  3383.  
  3384.  
  3385.  
  3386.  
  3387. Msg#:  499 *MODEM*
  3388. 06-06-92 00:39:54
  3389. From: JOHN T KOHL
  3390.   To: SYSOP (Rcvd)
  3391. Subj: CURRENT REVS/NEW ROMS?
  3392. What is the most recent ROM shipping in the v.32bis FAXmodem? When is the next
  3393. ROM upgrade due out (I saw the one about the  WinFax stuff in the
  3394. login-message--anything before then?)? And what bugs does it fix?
  3395.  
  3396.  
  3397. Msg#:  863 *MODEM*
  3398. 06-16-92 08:41:56
  3399. From: SYSOP
  3400.   To: JOHN T KOHL (Rcvd)
  3401. Subj: REPLY TO MSG# 499 (CURRENT REVS/NEW ROMS?)
  3402. The next ROM revision will be sent out to all registered users in mid July.  It
  3403. fixes problems with Winfax and other FAX software packages.  It also enables
  3404. the modem to initiate fall back and forward under different levels of line
  3405. quality. [Nathan]  Supra Technical Support
  3406.  
  3407.  
  3408. Msg#:  506 *MODEM*
  3409. 06-06-92 08:21:04
  3410. From: BRIAN LESTINA
  3411.   To: MIKE WHITE
  3412. Subj: V32BIS
  3413.         I need some help.  I can not connect to this BBS at 14.4 I have to set
  3414. up all kinds of weird shit and connect at 9600.  I can not get thru to tech
  3415. support and this kind of shit is really begining to  piss me off.  I just
  3416. received this modem form your exchange program, and  it has more problems then
  3417. the first one I got!!!  Does anybody test this  shit before you ship it?  The
  3418. modem you sent me has Rom ver F, but it won't connect to anything above 9600!!!
  3419. If I call anybody  at 14.4 it  starts to connect and then hangs up.  I have
  3420. tried every setting I could, but nothing works.  I want someone to straighten
  3421. this shit out!! Please  call me at home. 708-544-9435 I have and answering
  3422. machine and will get back to you.  I really do like this modem, and would like
  3423. to reccomend it  to my friends, but not until mine works 100 %....
  3424.  
  3425. Brian Lestina
  3426.  
  3427.  
  3428. Msg#:  560 *MODEM*
  3429. 06-07-92 23:40:36
  3430. From: MARK WHITE
  3431.   To: BRIAN LESTINA (Rcvd)
  3432. Subj: REPLY TO MSG# 506 (V32BIS)
  3433. It sounds like you have the ROM which has the fall back code.  To check this,
  3434. use the I3 command.  If you get a 1.200C then you do.  If you are only able to
  3435. connect at 9600, then most likely you have noisy phone lines or some other
  3436. problem.  Please DLed the file V32_Q&A.TXT for some more hints.  (In the MODEM
  3437. section).
  3438.  
  3439. To run at 14.4 requires a very clean line.  For instance, our BBS line is on a
  3440. very noisy phone line.  (We are 5 miles from our central office.)  We have done
  3441. extensive testing with all popular v32bis modems and they all exhibit line
  3442. noise problems on our phone lines.
  3443.  
  3444. All of our modems are tested on a test system before they are shipped out.  The
  3445. problems you are describing sound like your phone line, not our modem.
  3446.  
  3447. Mark - Supra Tech Support
  3448.  
  3449.  
  3450. Msg#:  516 *MODEM*
  3451. 06-06-92 17:22:53
  3452. From: BOB BRANSTETTER
  3453.   To: SYSOP (Rcvd)
  3454. Subj: ROM UPGRADE
  3455. Please put my name on your list for the Faxmodem V32bis ROM Upgrade.  I find it
  3456. impossible to connect with other Supra V32bis modems including this BBS.  Have
  3457. to use my old 2400 to make connection here.  No trouble connecting with other
  3458. modems at 144000.  Just Supras.
  3459.     My mailing address for the ROM UPgrade is:
  3460.                Bob Branstetter
  3461.                15821 Overbrook Lane
  3462.                Stanley, KS  66224
  3463.                Daytime (work) # (913) 344-5005
  3464.                Evenings (913) 897-5311
  3465.                                                         Thanks..
  3466.                                                                 Bob
  3467.  
  3468.  
  3469. Msg#:  872 *MODEM*
  3470. 06-16-92 09:38:10
  3471. From: SYSOP
  3472.   To: BOB BRANSTETTER
  3473. Subj: REPLY TO MSG# 516 (ROM UPGRADE)
  3474. Bob, You're on the list. Supra Technical Support
  3475.  
  3476.  
  3477. Msg#:  529 *MODEM*
  3478. 06-07-92 00:58:14
  3479. From: THE
  3480.   To: SYSOP (Rcvd)
  3481. Subj: THROUGHPUT IS 1600CPS WITH A 486/33 AND A 1650 UA
  3482. to 3000cps.  I am only getting 1600 cps, what is going on?  This is the
  3483. equivalent of running at 19200, not57600.Please help
  3484.  T     THIS IS MESSED UP Please call at 703-680-1779 asap yj        THIS IS
  3485. DRIVING ME CRAXZY.  i HAD THE WHOLE PC TAKENAPART TO PUT THIS uART IN., AND AM
  3486. NOT GETTING FULL PERFORMANCE.  tHANKS,nANCY cRONIG I was told by your tech
  3487. support dept that
  3488.  
  3489.  
  3490. Msg#:  561 *MODEM*
  3491. 06-07-92 23:47:45
  3492. From: MARK WHITE
  3493.   To: THE
  3494. Subj: REPLY TO MSG# 529 (THROUGHPUT IS 1600CPS WITH A 486/33 AND A 1650)
  3495. Simply putting in a 1650 UART does not guarntee that you will solve all of your
  3496. problems.  First, does your software enable the 16550?  If not, you can DLed a
  3497. file from the IBM section which will turn it on.  Next, what speed are you
  3498. running your serial port at?  Also what type of file are you DLing, if it is a
  3499. arc, zip etc. file , then the modem will have a difficult time compressing it
  3500. any further.  What type of connection are you making and at what carrier speed?
  3501. If you are getting a v42 or mnp4 connection, the error correction will give you
  3502. about a 15% increase over the carrier speed.  For more info, DLed the file
  3503. V32_Q&A.TXT in the IBM section.
  3504.  
  3505. Mark - Supra Tech Support
  3506.  
  3507.  
  3508. Msg#:  542 *MODEM*
  3509. 06-07-92 15:53:30
  3510. From: RICK CALICURA
  3511.   To: ERIC LAU
  3512. Subj: HELP ON SUPRA
  3513. Ihave the same problem, plus more.  Often, I will log onto a BBS @144 and it
  3514. will just hang there.  The only way to hang up is to turn it off.  Further, I
  3515. cannot get the v.32bis modem to log on to my local First Class User BBS at
  3516. higher than 2400 bps!  I have tried all the strings that SUPRA posted and that
  3517. my local SysOp downloaded. Moreove, this is the first time I ahave been able to
  3518. log on here as my v.32bis would just hang up after getting a CD message.  I
  3519. have reduced the setup to 9600 bps with hardware handshaking andit is working
  3520. (with an "LP"message).  I believe I need the new ROMS too, (sales said they
  3521. have put in an order for me).  My serial # is 285. The modem works perfectly on
  3522. BMUG at high speed, but usually requires me to set it at 38000 bps instead of
  3523. 57000. We'll keep hoping it will get straightened out.
  3524.  
  3525.  
  3526. Msg#:  564 *MODEM*
  3527. 06-08-92 01:24:29
  3528. From: JEREMY GRODBERG
  3529.   To: ALL
  3530. Subj: PROBLEMS
  3531. I'm haveing problems with my Supra FaxModem v.32bis.  1) calling this BBS and
  3532. some others, I frequently get garbage spweing out on the screen, rather than a
  3533. CONNECT message.  The APS BBS is a particular problem for me (phone 816 478
  3534. 4541).  Sometimes, it will even crash the modem.  2) I'm having problems
  3535. receiving faxes. (I have the Mac bundle, with version 1.2 roms and FAXstf
  3536. 2.2.0.)  I frequently can't negotiate even 9600 bps on received faxes, even
  3537. though I can send to the exact same faxes at 9600 bps with no problem.  What's
  3538. going on?
  3539.  
  3540.  
  3541. Msg#:  566 *MODEM*
  3542. 06-08-92 07:09:14
  3543. From: JOHN BUNGARD
  3544.   To: MARK WHITE-TECH SUPPORT
  3545. Subj: V32BIS MODEM PROBLEM
  3546. My modem drops the speaker output...total silence after the modem  is in the
  3547. re-dial mode(in other words when I get a busy from the remote modem line).
  3548. Every thing else seems to function ok and when I do get through there seems to
  3549. be no problem with the connection. Is this a defective modem? the string atl3
  3550. or atl2 have no effect on this problem. I have not been able to talk with Tech
  3551. support about this problem. Would appreciate your reply.
  3552.  
  3553.  
  3554. Msg#:  581 *MODEM*
  3555. 06-08-92 20:38:52
  3556. From: MARK WHITE
  3557.   To: JOHN BUNGARD (Rcvd)
  3558. Subj: REPLY TO MSG# 566 (V32BIS MODEM PROBLEM)
  3559. It does sound like it is a problem with the modem.  We do have an exchange
  3560. program.  See other messages or the announcement section for more info.
  3561.  
  3562. Mark - Supra Tech Support
  3563.  
  3564.  
  3565. Msg#:  568 *MODEM*
  3566. 06-08-92 11:10:32
  3567. From: ALAN NEAL
  3568.   To: SYSOP (Rcvd)
  3569. Subj: DEFECTIVE MODEM
  3570. I recently bought a V.32bis modem, and I think the product is excellent. 
  3571. However, the modem recently started acting funny. After about 20min, it forgets
  3572. how to dial. I tried resetting it and cycling power, but it won't work unless I
  3573. leave it off for a full 20 minutes.
  3574. . Once I'm connected, the modem is fine. After hanging up, a subsequent dial
  3575. command doesn't work.
  3576. . I read in an earlier message about your exchange policy. I faxed my VISA
  3577. number to you. Please give me an indication of when I can expect my new modem.
  3578. . By the way, I was very reluctent to leave a message here because of the 
  3579. somewhat hostile attitude of a few customers. After reading through the
  3580. messages and responses, I was able to glean quite a bit of information about my
  3581. modem. Further, assuming this thermal problem is taken care of in short order,
  3582. I am still quite pleased with the modem's performance. By the way, I haven't
  3583. had any trouble connecting here at 14.4.
  3584. . Thanks, Alan.
  3585.  
  3586.  
  3587. Msg#:  970 *MODEM*
  3588. 06-19-92 09:26:13
  3589. From: SYSOP
  3590.   To: ALAN NEAL
  3591. Subj: REPLY TO MSG# 568 (DEFECTIVE MODEM)
  3592. Alan, Did someone here get that exchange processed for you?  If not, please
  3593. send a FAX Attn: Nathan, and I'll get it to you.  If you did get a new modem,
  3594. how is it working for you?  Glad to hear that you like our product.  If you
  3595. have any questions, please let me know. [Nathan]  Supra Technical Support
  3596.  
  3597.  
  3598. Msg#:  572 *MODEM*
  3599. 06-08-92 15:34:06
  3600. From: STONEART INC.
  3601.   To: TECH SUPPORT
  3602. Subj: UNABLE TO CONNECT USING TWO IDEN
  3603. I have purchased two identical v32 v42bis supra modems one month ago and sent
  3604. one to south africa for the purpose of communicating between the two.  They
  3605. will not speak to eachother. We are using Quicklinefax software and have tried
  3606. everything. Please help - at wits end . Our fax number is (803) 571-5524 and
  3607. telephone (803) 571-3983. The problem is that we are not experienced modem
  3608. users and this is driving us crazy.  Please reply pronto.Thanks
  3609.  
  3610.  
  3611. Msg#:  574 *MODEM*
  3612. 06-08-92 16:16:21
  3613. From: STONE ART INC.
  3614.   To: TECH SUPPORT
  3615. Subj: NON CONNECTING MODEMS
  3616. F6GERBILDOC3  BCCN 6DNNNLPT1`STONE ART INC.                               June
  3617. 8th, 92
  3618. `
  3619. `
  3620. I called in earlier with a brief message concerning the non
  3621. `communication between two identical Supra fax modems V32.
  3622. `
  3623. We have been communicating for a year now with a computer in South Africa using
  3624. regular 2400bps modems with a limited communications software package which is
  3625. part of PFS First Choice.  This was easy but slow and the amount of data has 
  3626. increased substantially of late.  Hence the reason for the
  3627. `purchase of two high speed Supra modems.
  3628. `
  3629. We also bought Quicklink2 Fax software and have set up in accordance with
  3630. instructions in the manual.  One question, why should we set the modem speed at
  3631. 2400bps as suggested by you?  One time, the South African connection managed to
  3632. connect with this computer and exchange data, but it transferred at 2400bps and
  3633. no faster.  We thought that the modems were supposed to negotiate highest
  3634. possible speed if
  3635. `set to autobaud.
  3636. `
  3637. Anyway, after one barely successful transfer, we have been unable to get the
  3638. modems to connect.  Mine rings twice (I can hear it through the speaker) and
  3639. then cuts off and my screen tells me the line is busy (which it wasn't).  When
  3640. the South African connection dials me, the modem acknowledges RI when it rings,
  3641. and goes back to OK inbetween rings and just won't
  3642. `pick up.
  3643. `
  3644. The same happens when I try to transmit a fax to the overseas party, and yet if
  3645. I send a fax from our regular fax machine (not the faxmodem) the South African
  3646. modem accepts it.  By the same token, I know this faxmodem works here because
  3647. it has successfully faxed other parties both in the USA and
  3648. `South Africa.
  3649. `
  3650. Please call and try to help us with this problem since we need to be in
  3651. constant communication and no-one else is willing to assist since we bought the
  3652. modems direct from yourselves.  I have been trying to call your Tech Support
  3653. `line all day and it has been constantly busy.
  3654. `
  3655. Our telephone number is (803) 571-3983 or fax (803) 571-5524. I believe it is
  3656. necessary to talk to a technical representative about this, but if I am not in
  3657. the office when you call, please advise how I can reach someone on a non-busy
  3658. `line.
  3659. `
  3660. `Thank you,
  3661. `
  3662. `
  3663. `
  3664. `Vanessa Kauffmann
  3665.  
  3666.  
  3667. Msg#:  576 *MODEM*
  3668. 06-08-92 18:39:49
  3669. From: KIRK BLUM
  3670.   To: SYSOP (Rcvd)
  3671. Subj: SUPRA CONNECT
  3672. Hello, I left a message to the sysop on Friday and have some additional input.
  3673. I tried the WINFAX fix with my modem and it would not fax anything at all.  Any
  3674. suggestions there? Next, I seem to have an inordinate amount of trouble
  3675. connecting to your BBS with my Supra.  It will start to connect, show the
  3676. connect speed fall back then hang up.  I have ended up using a USRobotics
  3677. Courier HST dual standard which seems quite able to connect here with no
  3678. problem.  I had hoped that the Supra would be a better modem (more modern and
  3679. all that) BUT the HST seems quite a bit more reliable.  Do you think the ROM
  3680. upgrade will help out the situation or did I make a large (as well as
  3681. expensive) mistake in buying your product?  I would like to hear your side if
  3682. you would honor me with some sort of communication (DAY VOICE=408-370-7979 x
  3683. 315, FAX: 408-370-3399) or a message here (a message here is the least
  3684. desireable as I do have difficulty in connecting with your BBS using one of
  3685. your product.)  Thanks for your consideration,  Kirk- Engineer Award Software
  3686. Inc. (yes, the BIOS people)
  3687.  
  3688.  
  3689. Msg#:  582 *MODEM*
  3690. 06-08-92 20:42:27
  3691. From: MARK WHITE
  3692.   To: KIRK BLUM (Rcvd)
  3693. Subj: REPLY TO MSG# 576 (SUPRA CONNECT)
  3694. Read V32_Q&A.TXT in the MODEM section.  Yes, the new ROM will fix this 
  3695.  
  3696.  
  3697. Msg#:  710 *MODEM*
  3698. 06-12-92 16:56:14
  3699. From: DAVESTARR
  3700.   To: KIRK BLUM
  3701. Subj: REPLY TO MSG# 576 (SUPRA CONNECT)
  3702. Kirk, in your message number 485 of 6-5-92, you said the serial number of your
  3703. modem is 14e900001.  That's the same as my modem!  How about it, supra, what's
  3704. the deal?  Will this affect warranties, etc.?
  3705.    
  3706. Dave Starr
  3707.  
  3708.  
  3709. Msg#:  842 *MODEM*
  3710. 06-15-92 20:20:42
  3711. From: DREW MCEACHERN
  3712.   To: MARK WHITE (Rcvd)
  3713. Subj: REPLY TO MSG# 582 (SUPRA CONNECT)
  3714. n
  3715.  
  3716.  
  3717. Msg#:  890 *MODEM*
  3718. 06-16-92 17:31:29
  3719. From: JAMES HUSSIERE
  3720.   To: MARK WHITE (Rcvd)
  3721. Subj: REPLY TO MSG# 582 (SUPRA CONNECT)
  3722. Funny, that's the same registration as MY modem...
  3723.  
  3724. My dealer DID inform me when I got my modem that some of his others in stock
  3725. also bore the same number.
  3726.  
  3727. I'd like to know, too... will this screw up our registrations?  Should we be
  3728. expecting a new serial number sticker when the new ROMS are sent out?
  3729.  
  3730.  
  3731. Msg#:  925 *MODEM*
  3732. 06-17-92 18:45:38
  3733. From: MARK WHITE
  3734.   To: JAMES HUSSIERE
  3735. Subj: REPLY TO MSG# 890 (SUPRA CONNECT)
  3736. No, this will not affect your registration.  On the first runs of the modem we
  3737. had to use a sticker which did not have incrementing numbers.  In no way does
  3738. this affect your warranty or your ability to receive updated ROMs.  
  3739.  
  3740. Mark - Supra Tech Support
  3741.  
  3742.  
  3743. Msg#:  975 *MODEM*
  3744. 06-19-92 09:54:30
  3745. From: SYSOP
  3746.   To: KIRK BLUM
  3747. Subj: REPLY TO MSG# 576 (SUPRA CONNECT)
  3748. Kirk, I'll give you a call or FAX. [Nathan]
  3749.  
  3750.  
  3751. Msg#:  976 *MODEM*
  3752. 06-19-92 09:56:26
  3753. From: SYSOP
  3754.   To: DAVESTARR
  3755. Subj: REPLY TO MSG# 710 (SUPRA CONNECT)
  3756. Dave, No,  This will not affect warranty information. [Nathan]
  3757.  
  3758.  
  3759. Msg#:  578 *MODEM*
  3760. 06-08-92 19:47:00
  3761. From: DAVE ARNESON
  3762.   To: ALL
  3763. Subj: THIS IS CRAP!
  3764. I have FINALLY managed to log onto this board after 3 nights worth of attemps,
  3765. not to mention 30 or 40 connects which will be anice reminder of how crappy
  3766. this modem is when I get the bill from Ma Bell. LINE NOISE? My arse... Crapola!
  3767. I can connect to the Sierra BBS, 2 or 3 in NY, hell even a board in Australia
  3768. with NO problem. Try to call the Supra BBS and I'm told that the damn thing
  3769. can't even connect with another IDENTICAL modem! The one common denominator in
  3770. my ability to connect to these OTHER LD boards is the fact that they are NOT
  3771. being run on a Supra. Seems THOSE sysops were smarter than this one. The are
  3772. all using Hayes or USR, or even in one case a Practical Peripherals. Damn ! If
  3773. this isn't remedied post haste, I am going to upload all the messages I
  3774. captured ON SUPRAS OWN BBS to Genie, Compuserve, America Online, WWIV Net,
  3775. Prodigy, Intelec, you name it.... This kind of shoddy product must either be
  3776. FIXED or must DIE a fast death . I will NOT stand being ripped off so
  3777. blatantly. Oh, and try to call tech support? Busy signal...I had 3 different
  3778. lines autodialing it for 2 solid hours on Friday, and when one line DID get
  3779. through, after ringing 50 or 60 times a BOGUS recording that was fabricated by
  3780. Supra to sound like an AT&T automatic recording that told me "your party is not
  3781. answereing. You will now be disconnected...503 T2 " or some such nonsense. Sure
  3782. glad I didn't purchas a Fax program. Now I find that THIS is also a lie. Damn
  3783. thing doesnt FAX either. This is beginnng to smell like the biggest SCAM since
  3784. those dudes brought Manhattan for a song, a dance, and a couple bottles of rye.
  3785. Mark my words Supra, if this modem is not made 100% correct, i will literally
  3786. plaster ever bbs and online service in the country with this message thread on
  3787. YOUR board, which is probably  the most damning evidence I could muster....
  3788.  
  3789. GET WITH IT !
  3790.  
  3791.  
  3792. Msg#:  583 *MODEM*
  3793. 06-08-92 20:53:14
  3794. From: MARK WHITE
  3795.   To: DAVE ARNESON
  3796. Subj: REPLY TO MSG# 578 (THIS IS CRAP!)
  3797. 1.  Line noise
  3798.  
  3799. A.  We definatly have noisy phone lines.  We are 5 miles from the central
  3800. office.  According to the phone company, we are lucky to get 9600 let     alone
  3801. 14.4.  I have put a US Dual, Intel 14.4, and Hayes 14.4, they     all had the
  3802. same type of problems.  In fact, I was totally unable to     make the Hayes
  3803. call into the USR, but I could go the other way.
  3804.  
  3805. 2.  Read V32_Q&A.TXT in the MODEM section, it gives several hints as for
  3806. workarounds.  You need to send in your warranty card as mid-July we     will be
  3807. sending new ROMs to all registered owners.  We have     implemented the
  3808. OPTIONAL feature of v32bis, changing the baud rate on     noisy lines.
  3809.  
  3810. 3.  AT&T recording
  3811.  
  3812. A.  If only we had the knowledge and power to generate that message!!      That
  3813. message IS NOT generated by Supra, but by our local phone     company.  They
  3814. were suppose to fix it late last week.
  3815.  
  3816. Mark - Sura Tech Support
  3817.  
  3818.  
  3819. Msg#:  584 *MODEM*
  3820. 06-08-92 21:40:57
  3821. From: ANTHONY GREGG ROBERTS
  3822.   To: MARK WHITE (Rcvd)
  3823. Subj: REPLY TO MSG# 583 (THIS IS CRAP!)
  3824. If it truly is line noise, then why does this not seem to affect USR's and
  3825. Hayes? If it is truly line noise, then why don't you spend a few extra bucks a
  3826. month and get a dedicated data line? Surely that wouldn't be as costly as the
  3827. damage that all this hulabaloo is doing to your reputation. I too am very
  3828. pissed off at spending nearly $400 on a 14.4k modem  that barely functins at
  3829. 2400. As it is, I can connect with SOME of the boards I call at 14.4, but there
  3830. are 2 boards I call that are at 2400 and I can't connect at ALL with them. 
  3831.  
  3832. Does the FAX work or not ? Before i spend another PENNY on this product I want
  3833. a guarantee that it will indeed do what it is billed as being able to do. I
  3834. honestly haven't seen such a big stink since Spectrum Holobyte released the
  3835. first Falcon 3.0 version. 4 versions later its still buggy... 
  3836.  
  3837. I'm not sure how you other "dupes" feel but given the number of 9600 and 14.4
  3838. modems on the market I am really beginning to regret purchasin the Supra. Come
  3839. on Mark, how about doing something to inspire some confidence in a company that
  3840. has a rep thats sinking faster than the Titanic....
  3841.  
  3842. BTW, I was going to overlook this minor issue, but since I'm so steamed I think
  3843. I'll make a fuss over this also. One of the tiny LED's is out on the LED
  3844. display. The only time you notice is when it displays DC (the lower right
  3845. quadrant of the D). Should I return it to the retailer or send it you you guys
  3846. (dumb question eh?) 
  3847.  
  3848.  
  3849.  
  3850. Msg#:  654 *MODEM*
  3851. 06-11-92 00:59:20
  3852. From: MARK WHITE
  3853.   To: ANTHONY GREGG ROBERTS
  3854. Subj: REPLY TO MSG# 584 (THIS IS CRAP!)
  3855. >> why does this not seem to affact USR's and Hayes
  3856.  
  3857. A.  I am not sure what you are referring to. If you are referring to     using
  3858. one of those modems for our bbs, we have tried it, they had just     as bad of
  3859. noise problems.  If you are referring to why can a hayes     connect at 14.4 to
  3860. a certain bbs, but ours can't; I will restate, our     modem did not implement
  3861. the OPTIONAL feature of v32bis to change bauds     under adverse line
  3862. conditions.  This means that ALL v32bis modems that     use the Rockwell
  3863. RC144AC chipset have the same problem. (ZOOM, etc.)      BUT we, Supra, have
  3864. implemented this and are licensing it BACK to     Rockwell.  We will be mailing
  3865. a FREE rom to all registered owners     approx mid-July.  Rockwell will be
  3866. supplying the SUPRA code in its     roms towards the end of this year!!
  3867.  
  3868. >> If it is truly line noise, then why don't you spend a few extra bucks
  3869.  
  3870. A.  To solve our noise problem is NOT a few extra bucks a month.  It could
  3871. be several 1000 bucks a month (which would be putting in another T1
  3872. connection).  We are trying to siphon off 2 lines from our long     distance
  3873. T1, but this is governed by various agencies.  The only other     solution the
  3874. phone company had was to gold plate the wires.  We are     looking at several
  3875. different options.  This problem has NOT been easy     to pin down.  It has
  3876. taken numerous calls to the several phone     companies, plus exhaustive
  3877. testing, before we were able to get the     answer.
  3878.  
  3879. >> Does the fax work?
  3880.  
  3881. A.  With the rom you have, it depends on what piece of fax software you     are
  3882. using (class 1 works much better than class 2) and what fax     machines you
  3883. are calling.  The ROM v1.200C fixes all know problems     with both class 1 and
  3884. class 2 fax software.  Again, we will be sending     a FREE rom upgrade
  3885. mid-July to all registered owners.
  3886.  
  3887. >> how about doing something to inspire some confidence...
  3888.  
  3889. A.  We are doing everything we can, as quickly as we can to provide
  3890. enhancements to our modem.  As I mentioned, WE, SUPRA, implemented the
  3891. optional  baud change, not Rockwell, not Zoom, not QuickTel, but Supra did.
  3892.  
  3893. Mark - Supra Tech Support
  3894.  
  3895.  
  3896. Msg#:  711 *MODEM*
  3897. 06-12-92 17:00:40
  3898. From: DAVESTARR
  3899.   To: ANTHONY GREGG ROBERTS
  3900. Subj: REPLY TO MSG# 584 (THIS IS CRAP!)
  3901. I call here about once every 10 days, and have since I got my 14.4 modem in
  3902. April.  I have always got a connect the first time AND at 14.4.  I don't know
  3903. what your problem may be, but I have never had one logging on here.
  3904.   I'm not connected with Supra in any way except as a satisfied customer of
  3905. modems, memory boards & hard drive packages for my Amiga 2000.
  3906.   
  3907. Dave Starr
  3908.  
  3909.  
  3910. Msg#:  980 *MODEM*
  3911. 06-19-92 16:28:11
  3912. From: BILL HUTTIG
  3913.   To: DAVE ARNESON
  3914. Subj: REPLY TO MSG# 578 (THIS IS CRAP!)
  3915. I connect at 14.4 but over MCI.. AT%L%Q comes back as 021 013 which is pretty
  3916. noise line but I don't have problem...with getting the conncetion. Try a
  3917. difference Long distence carrier MCI 10222 SPrint 10333 ...etc..  Bill
  3918.  
  3919.  
  3920. Msg#: 1006 *MODEM*
  3921. 06-20-92 12:18:31
  3922. From: STEVE PEPIN
  3923.   To: DAVE ARNESON
  3924. Subj: REPLY TO MSG# 578 (THIS IS CRAP!)
  3925. What CRAPPY (to use your verbosity) software package are you trying to use to
  3926. send your faxes and do your modeming?  I have only one problem with my Supra,
  3927. and that is that my RBBS software seems to have problems controlling the modem
  3928. while it's trying to negotiate a reliable link. Everything else is OK. As for
  3929. the fax issue, I was originally using QuickLink II Fax as is was existing from
  3930. a Zoom modem that was replaced by the Supra, QLIIFAX would lock the modem up
  3931. after DOWNLOADING a file, but otherwise was OK, Heck, I was even able to FAX
  3932. with it. If something so cheap as QLIIFAX works somewhat, then I don't know
  3933. what peice of sh__t you are trying to use.
  3934.  
  3935.  
  3936. Msg#:  585 *MODEM*
  3937. 06-08-92 21:43:21
  3938. From: ANTHONY GREGG ROBERTS
  3939.   To: STONE ART INC.
  3940. Subj: USR 'S ETC
  3941. Why are USR Duals able to connect to Supra's BBS at high speed when the Supra
  3942. modem can not? Line noise? Explain this please///
  3943.  
  3944.  
  3945. Msg#:  589 *MODEM*
  3946. 06-08-92 22:40:35
  3947. From: ANDY STAHOWIAK
  3948.   To: DAVE ARNESON
  3949. Subj: I LOVE MY SUPRA!
  3950. Well, I had some minor problems with getting my Modem to work 100%. Like 1st
  3951. Buy New Modem Cable.. Does urs support Rtc/cts?  I really doubt, That someone
  3952. as HOT HEADED. Will or can Destroy Supras REP... $400.00? Someone burnt you! I
  3953. Paid 309.00 shipped! HA Before u going rainting and raving some more,why don't
  3954. u think! Supra is VERY Busy with the New Rom update. Trying to keep up with
  3955. orders...etc. I agree they neglected to test a few things,but Still HELL OF A
  3956. LOT CHEAPER than a USR! Which I also own. 
  3957.  
  3958. A Faithful Supra Fan! 
  3959.  
  3960.        Andrew
  3961.  
  3962.  
  3963. Msg#:  768 *MODEM*
  3964. 06-13-92 23:31:32
  3965. From: MATT BAKER
  3966.   To: ANDY STAHOWIAK (Rcvd)
  3967. Subj: REPLY TO MSG# 589 (I LOVE MY SUPRA!)
  3968. I
  3969.  
  3970. LOVE
  3971.  
  3972. MY
  3973.  
  3974. SUPRA 
  3975.  
  3976. TOO! 
  3977.  
  3978. Works fine on my end too. Sounds like these hot heads have the patience of a 2
  3979. year old kid on coffee.
  3980.  
  3981. * Matt
  3982.  
  3983.  
  3984. Msg#:  593 *MODEM*
  3985. 06-09-92 02:15:26
  3986. From: PORT
  3987.   To: SYSOP (Rcvd)
  3988. Subj: GENERAL MODEM FIXES
  3989. Hi I have had my Supra v32bis modem for almost a month and wasn't able to make
  3990. even one sucessful connect at 14400. Line noise is a big problem  but other
  3991. modem Co. have seem to over come some of the problems. I have had MANY connects
  3992. at 14400 but nothing on the screen , it just sits there and some times no
  3993. connect message but the modem says 144 on the display!.....I have even had
  3994. these problems at speeds as low as 2400 baud. But not too often..(it may be
  3995. with another Supra!) Frequently I get the same problem with 9600 baud ...VERY
  3996. FUSTRATING  now I'm sure that you also have your share of fustration as I read
  3997. the messages that come across your BBS .. I also am running a BBS and a
  3998. business...Now For the good news! THIS CONNECTION IS AT 14400 LP DC....... NOW
  3999. here is what I did .... First I READ the manual many time (somewhat lacking for
  4000. manual readers) and I read everything I could find on all the BBS's and set up
  4001. a test proceedure and documented all of my attempts to connect to a group of  
  4002. 10 BBS's , 3 local ( one less than a mile away) the rest in various places in
  4003. the US. I did this without much luck as I have stated and was ready to  send
  4004. the modem back and had talked to one of your customer support people  (a
  4005. female) whos name I have in a note book but can't locate at this time.. She was
  4006. very helpful and we both felt that the modem was defective as it seem to act
  4007. some what erracticly  (I still not ruling that completely out)some of the s
  4008. reg. would not always change ... I now have a AT modem setup string in PCPLUS
  4009. that has allowed me to connect at 14400 and very reliable at 9600 on all but
  4010. one of the 10 BBS's. This BBS has connected twice at 14400  and 2x at 12000 and
  4011. 2x at 9600 though one time it didnot make a connection but the fall back went
  4012. all the way to 3 300baud...this has happened only one other time ... I did get
  4013. the time in to check the line level and noise with the at%q and at%l command 
  4014. and the Q% returned 113 and the L% 22, most of the time at my location the Q%
  4015. command brings back a 033 or there abouts( have to check my notes) .. THE
  4016. setting s That I now use seems to have helped as before I could'nt connect at
  4017. all at 14400 My setup is At&F2&Q9 \N3 W1 S9=32 S11=50 S10=150 &W (I don't use
  4018. the spaces between the commands) I attribute the S10 and S11 command as making
  4019. the biggest improvement.. After adding the Q9 S9and the \N3 command I was able
  4020. to get more than a indication on the modem of the connect (I was showing a cd
  4021. and baud rate on the modem but no connect in the software.) the software
  4022. started to give me much more frequent connect messages  but only occasionly get
  4023. any readable data on the screen. The carrier would drop before I could enter my
  4024. name! After setting the S10 reg to 150 and the S11 reg to 50 I have had about a
  4025. 75 or better sucess rate connecting to 14400 BBS.. I did have to increase the
  4026. time out parameter in PCPLUS to 90 sec  so it would'nt time out  before making
  4027. the connection ... Now only One BBS and its in LA so some what local plus he's
  4028. a Ham Radio operator and has a Packet BBS as well as His Land Line his NO. is
  4029. 310 541 2503 I have a LARGE phone bill of 1min calls to him .... MY daytime
  4030. phone is 714 594 5051 and address is Port Barlow 382 N lemon ave Walnut CA
  4031. 91789 ..... GOOD LUCK ..........Port..
  4032.  
  4033.  
  4034. Msg#:  602 *MODEM*
  4035. 06-09-92 08:31:59
  4036. From: RICHARD HUMBERT
  4037.   To: SYSOP (Rcvd)
  4038. Subj: FAX PROBLEM
  4039. Using FAXPLUS when I send a mulit-page fax the receiving machine doesn't let my
  4040. maching know it rec'd the 1st page.  FAXPLUS then disconnects with  error beeps
  4041. to indicate failed transmission.  To a different FAX machine I can send a few
  4042. pages, then things break down.  Is there modem setup strings I can use to
  4043. affect this in any way?  I'm using version 1.65a of FaxTalk plus. Thanks...RICH
  4044.  
  4045.  
  4046. Msg#: 1052 *MODEM*
  4047. 06-22-92 05:16:31
  4048. From: SYSOP
  4049.   To: RICHARD HUMBERT
  4050. Subj: REPLY TO MSG# 602 (FAX PROBLEM)
  4051. Try FAXing at 4800 by modifying the FAXtsr command in DOS.  Type in: FAXtsr
  4052. /s4.  The new ROM chips that we will be sending out in mid-July may also help.
  4053. Be sure to send in your registration card. [Nathan]  Supra Technical Support
  4054.  
  4055.  
  4056. Msg#:  611 *MODEM*
  4057. 06-09-92 10:40:30
  4058. From: JONO MOORE
  4059.   To: SYSOP (Rcvd)
  4060. Subj: CONNECTING TO THIS BBS
  4061. What modem are you guys using on the BBS here?  I have a heck of a time
  4062. connecting, finally had to lock the modem at 4800 to make it on.  This is the
  4063. first time I've had trouble connecting with another modem at 14400 (including
  4064. other Supra V.32bis modems).
  4065.  
  4066.  
  4067. Msg#: 1055 *MODEM*
  4068. 06-22-92 05:22:39
  4069. From: SYSOP
  4070.   To: JONO MOORE
  4071. Subj: REPLY TO MSG# 611 (CONNECTING TO THIS BBS)
  4072. We are using our new Supra FAX V.32bis modems.  The problem that you are
  4073. encountering is severe line noise.  Much of this is on our end, you you may
  4074. want to haave your lines checked. [Nathan]  Supra Technical Support
  4075.  
  4076.  
  4077. Msg#:  612 *MODEM*
  4078. 06-09-92 11:20:02
  4079. From: JACK SPROUT
  4080.   To: DAVE ARNESON
  4081. Subj: YOUR ATTITUDE
  4082. HeHee You look and sound real Bad Dave... Suggest you think how you would
  4083. respond to the crap you wrote to the sysop here Personally, if Iwere the Sysop
  4084. here and this wasn't Tech Support, I'd lock you out... Cool it !!!  You'll get
  4085. faster service adand better results maybe...Never know until you try it... Jack
  4086.  
  4087.  
  4088. Msg#:  613 *MODEM*
  4089. 06-09-92 11:36:04
  4090. From: JACK SPROUT
  4091.   To: MARK WHITE (Rcvd)
  4092. Subj: SUPRA V32B REMOTE TO TECH BBS
  4093. Hi Mark!   Have one of your Supra V.32bis modems and love it! You are in the
  4094. unfortunate position of the target in the firing line here it looks like..
  4095. Well, if it makes any difference to ya, you done good! I can get past the Line
  4096. Noise by dialing here with your suggested Modem Init. string of:  ATNS37=9  So
  4097. what I can only connect at 9600 Baud. <grin>  Now about that ROM upgrade for
  4098. folks who have sent in their Warranty Cards in mid July  (the 15th?)...  How is
  4099. this being handled? I mean, by date of purchase, alphabetically by name, what? 
  4100. Also, are you simply going to ship the new ROM chips for us to install 
  4101. ourselves or ask we send back our beloved Supra's for "Factory Installation".
  4102. (No way do you get my modem back!...<grin>)... Sorry, if you posted all this
  4103. info and I just didn't find it and am not inclined to try to learn any more
  4104. about TBBS and search the message base. BTW, I'm a Sysop and have had good
  4105. fortune to be in a good clean line area and can connect in Terminal mode
  4106. everywhere else but here..(sorry) and Users of my BBS have had no complaints
  4107. dialing into the BBS through the Supra from 1200 to 14,400 bps connect... One
  4108. last thing, my name as user here and Supra owner is really  Drew Roberts of Ben
  4109. Lomond, CA  Voice verify:(408)336-8266 When I dialed in earlier, your BBS
  4110. didn't remember my password or, god forbid, I didn't....   Thanks for fine
  4111. support!   Drew, AKA Jack
  4112.  
  4113.  
  4114. Msg#:  656 *MODEM*
  4115. 06-11-92 01:18:26
  4116. From: MARK WHITE
  4117.   To: JACK SPROUT
  4118. Subj: REPLY TO MSG# 613 (SUPRA V32B REMOTE TO TECH BBS)
  4119. We have put together an upgrade kit.  This consists of the 2 ROMs, a dual
  4120. tipped screw driver (phillips, flat), and full instructions.  If you wind up
  4121. destroying the modem, no problem just send it back and we will take care of it.
  4122. If after looking at it, you decide you do not want to attempt it, then by all
  4123. means send it to us and we will take care of it.  We have used several people
  4124. who have never used a modem, let alone handled a chip, serve as test subjects.
  4125. They passed with flying colors.  So I am certain that we will not need to
  4126. replace more than 1 or 2 modems, if that.
  4127.  
  4128. We will have all warranty cards entered by that time, so they will go out
  4129. enmass.
  4130.  
  4131. Mark - Supra Tech Support
  4132.  
  4133.  
  4134. Msg#: 1000 *MODEM*
  4135. 06-20-92 05:31:38
  4136. From: PATTI IRWIN
  4137.   To: MARK WHITE (Rcvd)
  4138. Subj: REPLY TO MSG# 656 (SUPRA V32B REMOTE TO TECH BBS)
  4139. Well add me to the upgrade list.. (I have rom version 1.000d or so)..  
  4140.  
  4141. Patti Irwin 3025 Marvin Ave. Erie, PA 16504
  4142.  
  4143. I already sent the registration card in a long time ago so should be no problem
  4144. there..
  4145.  
  4146.  
  4147. Msg#: 1002 *MODEM*
  4148. 06-20-92 05:43:28
  4149. From: PATTI IRWIN
  4150.   To: PATTI IRWIN (Rcvd)
  4151. Subj: REPLY TO MSG# 1000 (SUPRA V32B REMOTE TO TECH BBS)
  4152. Oh yes the Serial number just in case is... 14e 001400
  4153.  
  4154.  
  4155. Msg#:  616 *MODEM*
  4156. 06-09-92 13:12:06
  4157. From: KIRK BLUM
  4158.   To: SYSOP (Rcvd)
  4159. Subj: TELIX AND ATN
  4160. Nathan, thank you for your help earlier today.  I have discovered some TELIX
  4161. and V.32bis settings that may help others log on here (before upgrading to the
  4162. new ROMs).  Per your suggestion of trying ATN0 S37=9 I was able to log on here.
  4163. That would be a pain to remember before dialing here everytime though.  What I
  4164. found works is setting ATN0 s37=0 which casues the modem to connect at the
  4165. speed of the last AT command.  I then set my Supra phonebook/dialer to 9600
  4166. baud which casues the modem to lock at 9600 baud when dialing YOU.  I can leave
  4167. other v.32bis modem entries at 19200 which will allow those to connect at
  4168. 14.4k.  The step down in speed is handled automatically.  NOTE: Telix must be
  4169. set to auto baud detect OFF for this to work.  It seems to work and when I get
  4170. my ROM upgrade I can simply set the Supra BBS entry back to 19200 thus
  4171. attempting to connect at 14.4k!!!  No special init strings required or nothing.
  4172. Just pick the dial entry and go!   Hope this helps and thanks again.  Kirk
  4173.  
  4174. P.S. the Award Software BBS number is (408)370-3139 and is a v.32bis capable if
  4175. any one wants to try to connect to us at 14.4k  Our board is public but is
  4176. primarily for Award BIOS users and customers.
  4177.  
  4178.  
  4179.  
  4180. Msg#:  747 *MODEM*
  4181. 06-13-92 12:18:49
  4182. From: MARK WHITE
  4183.   To: ANTHONY GREGG ROBERTS
  4184. Subj: REPLY TO MSG# 616 (TELIX AND ATN)
  4185. I do not understand why you refuse to listen to us.  If this was not correct,
  4186. than why has Rockwell licensed the new code from us.  Why do ZOOM VFX, Xeba,
  4187. etc. modems have the same problems. Why are we sending out a free ROM to all
  4188. registered owners.  Believe me, it will not be a small
  4189.  expense. Why have we had our engineers working day and night on this.  As far
  4190. as other modems working on noisy lines, they have implemented a OPTIONAL
  4191. feature of v32bis, which we have now implemented ourselves.
  4192.  
  4193. Mark - Supra Tech Support
  4194.  
  4195.  
  4196. Msg#: 1057 *MODEM*
  4197. 06-22-92 05:30:08
  4198. From: SYSOP
  4199.   To: KIRK BLUM
  4200. Subj: REPLY TO MSG# 616 (TELIX AND ATN)
  4201. Kirk, Thanks for the information. [Nathan]
  4202.  
  4203.  
  4204. Msg#:  618 *MODEM*
  4205. 06-09-92 15:15:44
  4206. From: TOM LAWCOCK
  4207.   To: SYSOP (Rcvd)
  4208. Subj: MODEM
  4209. Nathan, I just purchased a Suprafaxmodem V.32, ser #006879.  The modem seems to
  4210. be working fine as a modem but as a sender of faxes it FAILS. I'm trying to use
  4211. Winfax, I have downloaded and am using the "fixed" mod file from your BBS, I've
  4212. tried switching group settings, all to no avail.  The modem will attempt to
  4213. establish communications then fail...with a fax communication failure message. 
  4214. Any ideas???  Will the new ROMS fix the problem, the faxes I'm trying to talk
  4215. to are Sharps.  I'd appreciate any thoughts you have, and PLEASE put me on the
  4216. ROM upgrade list. Tom Lawcock 710 W. 3rd Street Mesa, AZ 85201
  4217.  
  4218.  
  4219. Msg#: 1058 *MODEM*
  4220. 06-22-92 05:35:53
  4221. From: SYSOP
  4222.   To: TOM LAWCOCK (Rcvd)
  4223. Subj: REPLY TO MSG# 618 (MODEM)
  4224. Tom, Try setting the modem in Winfax to 4800.  Yes, the new ROM chips will help
  4225. this problem.  (The Winfax patch works for most people, but not for all).  I've
  4226. put you on the list to be sure that you get the new ROMs.  We'll be sending
  4227. them out to all registered users in mid-July. [Nathan]  Supra Technical Support
  4228.  
  4229.  
  4230. Msg#:  621 *MODEM*
  4231. 06-09-92 16:53:48
  4232. From: JASON APONE
  4233.   To: ANYONE AND THEIR GRANDMOTHERS
  4234. Subj: FAX PROBLEM
  4235. Hi, i have a supra fax modem v32bis.  It works wonderful as a modem, and seems
  4236. like a gift from heaven to a previous 2400 user like me.
  4237.   However  the fax dosent seem to work correctly.  Sure, i can receive fine,
  4238. but when i send, the fax is sent but the receiver gets an error and my
  4239. faxprogram thinks the fax to be not sent.  The error the receiver gets has
  4240. something to do with not getting page enders, etc.  I am using Fax Plus which
  4241. came with the modem and I DID make the changes in the config that the addendum
  4242. that came in the software envelope recommended.
  4243.  
  4244.  
  4245. Msg#:  627 *MODEM*
  4246. 06-09-92 20:46:54
  4247. From: ANTHONY GREGG ROBERTS
  4248.   To: ALL
  4249. Subj: BBS'S. ETC
  4250. Has anyone here ever called the USR BBS? Lets start a conversation comparing
  4251. the general thrust of the message bases there vs. here. I for one was quite
  4252. amazed to talk to a girl at Supra today who was "seemingly unaware" of all the
  4253. bullshit going down here. I told here that I was able to log on to the SUpra
  4254. BBS (she tried to keep her astonisment down, since of course its common
  4255. knowledge that these things won't connect at greater than 2400 with any modem
  4256. other than a USR, Hayes, or PP) then I told ther that I had buffered 60 or 70
  4257. messages. She tried to tell me that she had mostly talked to pleased
  4258. customers...RIGHT. How many pleased customers call CS?? Hardly.. When I told
  4259. her I had captured these messages, she promptly put me through to a bigger wig
  4260. who smooth talked me to high heaven. Bottom line. I won't believe it until I
  4261. connect to it. 
  4262.  
  4263. 350$ down the tubes...and to thing, that for an extra $150 (USR Sysop deal ) I
  4264. coulda had a Dual Standard....!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  4265.  
  4266.  
  4267. I would like to hear from some people who have also owned Duals and HST's and
  4268. ULTRAS..so far the only positive comments I see here are from people like "yea,
  4269. well I just moved up from 1200 baud and even though I can only connect to 2 out
  4270. of 8 boards I think this is groovy", so how about some commentary from some of
  4271. you who have owned REAL modems....
  4272.  
  4273.  
  4274. Msg#:  631 *MODEM*
  4275. 06-10-92 00:30:26
  4276. From: PORT BARLOW
  4277.   To: SYSOP (Rcvd)
  4278. Subj: TYPO IN MSG 593
  4279. The AT commands that I listed in My last MSG had a typo the two commands that I
  4280. listed should have been S9 and S10. The command line that I have in PCPLUS is:
  4281.    AT&F2&Q9\N3WS95=32S11=50S9=30S10=150&W
  4282.  This works for me. It takes a long time to connect 60 sec+
  4283. and the BBS has droped me one time in the last 3 calls but the two connects
  4284. were at 14400. It still isn't Right! 
  4285.                                      Port
  4286.  
  4287.  
  4288. Msg#: 1062 *MODEM*
  4289. 06-22-92 05:56:20
  4290. From: SYSOP
  4291.   To: PORT BARLOW
  4292. Subj: REPLY TO MSG# 631 (TYPO IN MSG 593)
  4293. Take the \N3 out of the string.  Also, set S9 to 4, as I suggested in a
  4294. previous message.  Make sure that your port is set at 19,200.  You can increase
  4295. this if you want, after you are sure that the modem init string is correct. 
  4296. [Nathan]  Supra Technical Support
  4297.  
  4298.  
  4299. Msg#:  636 *MODEM*
  4300. 06-10-92 04:51:01
  4301. From: JONATHAN BURROWS
  4302.   To: SYSOP (Rcvd)
  4303. Subj: VERIFICATION
  4304.         I was just wondering what the average waiting period is for
  4305. verification on a sysop order? Thanks
  4306.  
  4307.  
  4308. Msg#: 1065 *MODEM*
  4309. 06-22-92 06:08:34
  4310. From: SYSOP
  4311.   To: JONATHAN BURROWS
  4312. Subj: REPLY TO MSG# 636 (VERIFICATION)
  4313. The verification process takes about one week.  If I see your name, I'll leave
  4314. you message telling you that you're in the computer.  Did you place an order?
  4315. Would you like me to check the status of your order? [Nathan] 
  4316.  
  4317.  
  4318. Msg#:  638 *MODEM*
  4319. 06-10-92 06:42:37
  4320. From: JAMES MARPLE
  4321.   To: ANTHONY GREGG ROBERTS
  4322. Subj: CONNECTING TO A SUPRA
  4323. I have never had problems here pr elsewhere connecting to a 14.4K Supra modem
  4324. at 14.4K. 
  4325.  
  4326.  
  4327. Msg#:  639 *MODEM*
  4328. 06-10-92 08:00:31
  4329. From: JOHN BUNGARD
  4330.   To: MARK WHITE (Rcvd)
  4331. Subj: RMA #
  4332. Mark, I am the party that has a problem with the modem that drops the speaker
  4333. in the redial process after the line detects busy. This is an intermittent
  4334. problem. Will you please issue me an RMA number? I can never get through to
  4335. tech support on the voice line. You may call me at (713) 461-4534 betwee 9:00AM
  4336. and 5:00PM entral daylight time.Maby I should get thr New Rom replaced at the
  4337. same time. Please let me know the turn-around time.
  4338.  
  4339.  
  4340. Msg#:  706 *MODEM*
  4341. 06-12-92 13:23:28
  4342. From: MARK WHITE
  4343.   To: JOHN BUNGARD (Rcvd)
  4344. Subj: REPLY TO MSG# 639 (RMA #)
  4345. RA# 0612523, I have marked on the form your problem and asked them to install
  4346. the new rom.
  4347.  
  4348.  
  4349. Msg#:  653 *MODEM*
  4350. 06-11-92 00:19:11
  4351. From: THOMAS MCWILLIAMS
  4352.   To: SYSOP (Rcvd)
  4353. Subj: NO BUSY DETECT
  4354. Hello, my new Supra seems to work more or less. However, it won't detect a busy
  4355. signal. It is the V32bis external model, serial number 6186. The rom is
  4356. identified as V1.000-E TR14-Jxxxx-001 003. Is there a problem with this rom? Or
  4357. is the failure to detect the busy signal a hardware error, and should it be
  4358. returned for  repair?
  4359.   
  4360. Thanks you,
  4361.   
  4362. Thomas
  4363.  
  4364.  
  4365. Msg#:  748 *MODEM*
  4366. 06-13-92 12:26:47
  4367. From: MARK WHITE
  4368.   To: THOMAS MCWILLIAMS (Rcvd)
  4369. Subj: REPLY TO MSG# 653 (NO BUSY DETECT)
  4370. The problem is with your busy signal, it is slightly out of spec.  Apparantly
  4371. our modem was too tightly adherring to the spec.  Our new ROM has slightly
  4372. expanded what it is looking for.
  4373.  
  4374. Mark - Supra Tech SUpport
  4375.  
  4376.  
  4377. Msg#:  896 *MODEM*
  4378. 06-16-92 22:59:46
  4379. From: THOMAS MCWILLIAMS
  4380.   To: MARK WHITE (Rcvd)
  4381. Subj: REPLY TO MSG# 748 (NO BUSY DETECT)
  4382. Thanks for the reply. I have sent my registration in. What more do I need to do
  4383. to get a new rom?
  4384.  
  4385. Here is my address:
  4386.  
  4387.        Thomas McWilliams
  4388.        2600 N. Glebe Rd.
  4389.        Arlington, VA 22207-3549
  4390.  
  4391.  Supra V32bis FAX modem S/N 14E - 006186
  4392.   
  4393. Put me on your list for the upgrade. PS: Please tell Bell Atlantic that their
  4394. busy signal is out of spec.
  4395. :-)
  4396.  
  4397.  
  4398.  
  4399. Msg#:  658 *MODEM*
  4400. 06-11-92 03:15:11
  4401. From: DONALD WATSON
  4402.   To: SYSOP (Rcvd)
  4403. Subj: ROM UPGRADE
  4404. Please put me on your list for the new ROM upgrade. My mSupraFaxModem V32bis
  4405. has a serial number of 14E 003323. My name and address: Rainer Denzinger
  4406.  Waxensteinstrasse 48a
  4407.  8900 Augsburg
  4408.  Germany Thanks for the new ROMS, I am waiting for!
  4409.  
  4410.  
  4411. Msg#: 1072 *MODEM*
  4412. 06-22-92 06:40:00
  4413. From: SYSOP
  4414.   To: DONALD WATSON (Rcvd)
  4415. Subj: REPLY TO MSG# 658 (ROM UPGRADE)
  4416. Donald,   The new ROMs will be sent out to all registered users.  I have put
  4417. your name on our list to be sure that you get them. [Nathan] Supra Technical
  4418. Support
  4419.  
  4420.  
  4421. Msg#:  659 *MODEM*
  4422. 06-11-92 03:17:33
  4423. From: DONALD WATSON
  4424.   To: SYSOP (Rcvd)
  4425. Subj: PULSE DIAL BUG
  4426. What about my note to you, which I wrote last week! Did you test the bug while
  4427. the modem is dialing in pulse mode (phone is not disconnected)? Please give me
  4428. an answer and try to fix this ugly bug in the new ROMs.
  4429.  
  4430.  
  4431. Msg#: 1073 *MODEM*
  4432. 06-22-92 06:41:36
  4433. From: SYSOP
  4434.   To: DONALD WATSON (Rcvd)
  4435. Subj: REPLY TO MSG# 659 (PULSE DIAL BUG)
  4436. Donald, I talked to another person in Germany who could not get the modem to
  4437. pulse dial.  I'll look into the problem, and get back to you. [Nathan]  Supra
  4438. Technical Support
  4439.  
  4440.  
  4441. Msg#:  660 *MODEM*
  4442. 06-11-92 03:37:10
  4443. From: JONATHAN SIEGEL
  4444.   To: SYSOP (Rcvd)
  4445. Subj: FLAKY RESULT CODES
  4446. I'm having a bit of trouble with my new SupraFaxModem v.23bis. Specifically,
  4447. the modem isn't (or doesn't seem to be) returning the result codes it ought to
  4448. upon making a connection.
  4449.  
  4450.  
  4451. I'm running it under Qmodem, Telemate 3.01, and Zcomm, all on a 386/DX-20.  The
  4452. Init string I'm using is AT&F2W2 (The "W2" is in there so that transfer times,
  4453. etc, are properly calculated.)
  4454.  
  4455. I seem to have little trouble connecting at high speed, but I get no result
  4456. code when connected to a standard 2400-baud modem.  The modem's front panel
  4457. shows "CD" and "24," but the software never gets the message.  The only way I
  4458. can connect to a 2400-bps modem is to issue the AT\N0 command...not something
  4459. I'd relish doing every time I make a call.  Can anyone help?  I've been unable
  4460. thus far to reach your voice supprt line/.  
  4461.  
  4462. Thanks,
  4463.  
  4464. Jonathan
  4465.  
  4466. P.S.  Taking the "W2" out of the init string doesn't seem to make a difference
  4467. -- not that it should.
  4468.  
  4469.  
  4470. Msg#:  758 *MODEM*
  4471. 06-13-92 14:42:06
  4472. From: MARK WHITE
  4473.   To: JONATHAN SIEGEL (Rcvd)
  4474. Subj: REPLY TO MSG# 660 (FLAKY RESULT CODES)
  4475. Your problem is not with the modem, but rather with the BBS you are calling.
  4476. BBSes that immediatly on connection start sending information will interfer
  4477. with the negotiation for v42bis and mnp.  That is why it works when you send
  4478. the \N command, you have told the Supra modem to not attempt an error
  4479. correction  connection.
  4480.  
  4481. Mark - Supra Tech Support
  4482.  
  4483.  
  4484. Msg#: 1081 *MODEM*
  4485. 06-22-92 08:27:31
  4486. From: JONATHAN SIEGEL
  4487.   To: MARK WHITE (Rcvd)
  4488. Subj: REPLY TO MSG# 758 (FLAKY RESULT CODES)
  4489. Thanks for the info....I was able to contact your voice Tech Support, and was
  4490. told the same thing.  And yes, the BBS systems with which I was having trouble
  4491. did indeed send info immediately upon connection (hey were all *ix systems
  4492. which sent login: prompts)
  4493.  
  4494. Thanks again!
  4495.  
  4496.  
  4497. Msg#:  665 *MODEM*
  4498. 06-11-92 06:24:46
  4499. From: JASON SLATER
  4500.   To: SYSOP (Rcvd)
  4501. Subj: PROBLEMS (SIGH..) & SOLUTIONS
  4502. i sure with that I had enough answers to cover all my questions, but..
  4503.  
  4504. thank you all (all tech support people - I feel you have been very helpful ,
  4505. and also all the users - it's good to know I'm not alone out there!)
  4506.  
  4507. answers:  yes, I called once @ 2400, S37=whatever for 2400, and dumped all the
  4508. messages you all posted,  assimilated the information, and called back here @
  4509. 9600.  mucho better. also, I can connect w/dual standards at 9600 now, instead
  4510. of 14.4 just sitting there doing nothing (or pumping out the garbage text), but
  4511. hey - I'm still working on getting that part down pat.  a number that I can't
  4512. connect to @ 14.4 yet (which is Dual Standard), that a friend with a Zyxel 14.4
  4513. has connected at 14.4 successfully with, is @ (310) 609-2176.  it's a very
  4514. large PD board, so maybe give it a call anyway.   the AT N S37=9 is great.   
  4515. also, you have answered my questions re: AT*H and AT)M  -- neither of these
  4516. options has been implemented.. yet.  kinda like an adventure.
  4517. >get treasure
  4518.  
  4519. Sorry.  You can't do that... yet.
  4520.  
  4521. (whatever)
  4522.  
  4523. anyway, a problem:  my speaker passed the margin of working/not working, and
  4524. now it's out cold.  I think I got a defective speaker or something, but I don't
  4525. have the time (and can't afford having no highspeed modem for the round trip to
  4526. Supra Corp. while Supra replaces the speaker) -- so is it possible for Supra to
  4527. mail me a replacement speaker??..  
  4528.  
  4529. also, I'm sending in my registration card today for the 14.4, but if you could
  4530. possibly get the ROM out faster (if I include my name & address, which I am
  4531. about to do), see if you could make me real happy ;-) 
  4532.  
  4533. that's it.  it IS a good modem, all you non-believers!
  4534.  
  4535. Jason Slater 4219 Dauntless Drive Palos Verdes, CA  90274 (310) 541-3131 voice 
  4536. (310) 544-2027 data (310) 377-7067 Fax (standalone)
  4537.  
  4538. ser#14E 004702
  4539.  
  4540.              -- off to work on some more 14.4's
  4541.  
  4542.  
  4543. Msg#: 1080 *MODEM*
  4544. 06-22-92 08:25:30
  4545. From: SYSOP
  4546.   To: JASON SLATER
  4547. Subj: REPLY TO MSG# 665 (PROBLEMS (SIGH..) & SOLUTIONS)
  4548. Jason, I'll give you a call for your bad speaker.  If you can do 9600, you
  4549. might be able to do 12000 with AT N S37=10.  Give it a try. [Nathan]   Supra
  4550. Techncial Support
  4551.  
  4552.  
  4553. Msg#:  666 *MODEM*
  4554. 06-11-92 07:41:07
  4555. From: ALAN NEAL
  4556.   To: SYSOP (Rcvd)
  4557. Subj: LINE NOISE
  4558. I use the Supra v.32bis to connect to R&E's on occasion. Sometimes I get 
  4559. through with a solid 9600 connection. Sometimes I can only connect at 4800 with
  4560. lots of RE messages and aborted downloads.
  4561. . They advertise a DUAL ELIMINATOR which connects between the modem and the
  4562. phone line. They claim that this cleans up the line noise. I think they want
  4563. around $30 for it.
  4564. . Is this thing just a band pass filter? Is it worth trying? Has anybody has
  4565. experience with this product?
  4566. . Alan.
  4567.  
  4568.  
  4569. Msg#: 1083 *MODEM*
  4570. 06-22-92 08:44:12
  4571. From: SYSOP
  4572.   To: ALAN NEAL
  4573. Subj: REPLY TO MSG# 666 (LINE NOISE)
  4574. Alan, The RE's are from line noise.  I am not familiar with filtering systems,
  4575. and can not tell you if they actually work. [Nathan]  Supra Technical Support
  4576.  
  4577.  
  4578. Msg#:  669 *MODEM*
  4579. 06-11-92 11:17:36
  4580. From: ALFREDO ROJAS
  4581.   To: SYSOP (Rcvd)
  4582. Subj: RETURNED MODEM
  4583. How do I know if I have the new rom, new modem?
  4584.  
  4585.  
  4586. Msg#:  749 *MODEM*
  4587. 06-13-92 12:33:43
  4588. From: MARK WHITE
  4589.   To: ALFREDO ROJAS (Rcvd)
  4590. Subj: REPLY TO MSG# 669 (RETURNED MODEM)
  4591. Do a AT I3.  The current ROM is 1.200C.
  4592.  
  4593. Mark - Supra Tech Support
  4594.  
  4595.  
  4596. Msg#:  936 *MODEM*
  4597. 06-18-92 07:41:10
  4598. From: ALFREDO ROJAS
  4599.   To: MARK WHITE (Rcvd)
  4600. Subj: REPLY TO MSG# 749 (RETURNED MODEM)
  4601. Ok, thanks...
  4602.  
  4603.  
  4604. Msg#:  674 *MODEM*
  4605. 06-11-92 16:38:21
  4606. From: ERNIE BLANCHARD
  4607.   To: MARK WHITE (Rcvd)
  4608. Subj: V.32BIS MODEM
  4609. Mark I left you a message in the general area asking for help with a problem. I
  4610. thought you would get it anyway but just wanted to make sure.
  4611.                         Ernie Blanchard
  4612.  
  4613.  
  4614. Msg#:  676 *MODEM*
  4615. 06-11-92 20:07:22
  4616. From: ALLEN JOHNSON
  4617.   To: MARK WHITE (Rcvd)
  4618. Subj: V.32BIS RESETS
  4619. Hi, I purchased one of your V.32bis modems about a month ago and have been 
  4620. greatly pleased by its performance. Recently, I have been experiencing a small
  4621. problem with the modem.
  4622.  
  4623. When I first tell the modem to dial and it receives a BUSY signal, it will 
  4624. reset. I can tell my software {COMMO} to redial and this reset may or may not
  4625. occur again.
  4626.  
  4627. I have noticed that this problem only crops up after the modem has been turned
  4628. on, that is, usage after the first couple of dial attempts does not cause the
  4629. problem to recur UNLESS I have to turn off the modem for whatever reason.
  4630.  
  4631. I scanned through your messages and noticed that a gentlemen mentioned a 
  4632. similar problem in message #227 in the Modem message area.
  4633.  
  4634. My modem initialization string is ATZ0\N3%C0S95=47
  4635.  
  4636. ATI3 returns V 1.000-E TR14-Jxxx-001 003
  4637.  
  4638. Also, I would like to have the ROM update sent to me when it is available. My
  4639. address is:
  4640.                         Allen C. Johnson
  4641.                         800 Ash Drive
  4642.                         Yuma, AZ  85364
  4643.  
  4644. I might also mention that I have called your BBS twice and both times have been
  4645. able to get a 14400 connection without difficulty. For those who might be
  4646. interested, my NRAM settings follow:
  4647.  
  4648. ACTIVE PROFILE: B1 E1 L2 M0 N1 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R0 &S0
  4649. &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:050
  4650. S08:002 S09:006 S10:014 S11:050 S12:050 S18:000 S25:005 S26:001 S36:007 S37:000
  4651. S38:020 S44:003 S46:136 S48:007 S49:008 S50:255
  4652.  
  4653. STORED PROFILE 0: B1 E1 L2 M0 N1 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R0
  4654. &S0 &T4 &X0 S00:000 S02:043 S06:002 S07:050 S08:002 S09:006 S10:014 S11:050
  4655. S12:050 S18:000 S25:005 S26:001 S36:007 S37:000 S38:020 S44:003 S46:136 S48:007
  4656. S49:008 S50:255
  4657.  
  4658. STORED PROFILE 1: B1 E1 L2 M0 N0 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K5 &Q8 &R0
  4659. &S0 &T4 &X0 S00:000 S02:043 S06:002 S07:050 S08:002 S09:006 S10:014 S11:050
  4660. S12:050 S18:000 S25:005 S26:001 S36:007 S37:009 S38:020 S44:003 S46:136 S48:007
  4661. S49:008 S50:255
  4662.  
  4663. I should add that my second setting works with GEnie. GEnie requires that 
  4664. hardware handshaking be turned off, thus the &K5 and &Q8.
  4665.  
  4666.  
  4667.  
  4668.  
  4669. Msg#:  703 *MODEM*
  4670. 06-12-92 11:35:58
  4671. From: JAMES MARPLE
  4672.   To: ALLEN JOHNSON (Rcvd)
  4673. Subj: REPLY TO MSG# 676 (V.32BIS RESETS)
  4674. I have the same problem. Sometimes, after a few calls usually, my modem will
  4675. reset itself when it is redialing and gets a busy signal. It is like there is a
  4676. big drain on the power supply or something as I get a very audible click thru
  4677. the speaker and the alphanumeric leds do their self test when it resets. This
  4678. is VERY frustrating. Does Supra have an answer for this problem yet?
  4679.  
  4680.  
  4681. Msg#:  677 *MODEM*
  4682. 06-11-92 20:21:37
  4683. From: JONATHAN GREENBERG
  4684.   To: ALAN NEAL (Rcvd)
  4685. Subj: R&E DUAL ELIMINATOR
  4686. I bought one of R&E's DUAL ELIMINATORS a week ago, and have had very poor luck
  4687. with it.  It seems to be nothing more than a surge protector that plugs into  
  4688. an electric outlet.  A little plastic box with a metal ground connector and  
  4689. two modular jacks.  I stopped using it.  Had one week of horrible connections  
  4690. with R&E.  Tonight I was on for an hour at 14.4 and it was rock solid.  This  
  4691. modem is great when conditions are right.
  4692.  
  4693. For all - started using S9=30 and S10=160, and connected here at 12.0 for the  
  4694. first time.
  4695.  
  4696. Jon
  4697.  
  4698.  
  4699. Msg#:  753 *MODEM*
  4700. 06-13-92 13:23:44
  4701. From: ALAN NEAL
  4702.   To: JONATHAN GREENBERG (Rcvd)
  4703. Subj: REPLY TO MSG# 677 (R&E DUAL ELIMINATOR)
  4704. Thanks for saving me $30. By the way, I've been using AT N s37=11 and getting
  4705. 14.4 from R&E's for the first time. I'm using it here, but have connected at
  4706. 14.4 without it.
  4707.   SYSOP: The replacement modem you sent me works great! Thanks for the super
  4708. turn-around time. Alan.
  4709.  
  4710.  
  4711. Msg#:  688 *MODEM*
  4712. 06-12-92 06:44:24
  4713. From: KEITH SITTER
  4714.   To: MARK WHITE (Rcvd)
  4715. Subj: FAX
  4716. Mark , Connie asked me to let you know my experiences w/the fax
  4717. software/hardware I could not get ANY CLASS1 software to receive more than one
  4718. or two pages at a time but the CLASS2 driver & software from MAGICSOFT (MTEZ)
  4719. works perfectly as far as I can tell  Also the full screen editor is the pits
  4720. !!
  4721.  
  4722.  
  4723. Msg#:  737 *MODEM*
  4724. 06-13-92 11:07:09
  4725. From: MARK WHITE
  4726.   To: KEITH SITTER (Rcvd)
  4727. Subj: REPLY TO MSG# 688 (FAX)
  4728. What version of the ROM are you using? (AT I3).  What software are you using?
  4729.  
  4730. Mark - Supra Tech Support
  4731.  
  4732.  
  4733. Msg#:  934 *MODEM*
  4734. 06-18-92 06:44:01
  4735. From: KEITH SITTER
  4736.   To: MARK WHITE (Rcvd)
  4737. Subj: REPLY TO MSG# 737 (FAX)
  4738.  ATI3= V1.000-E TR14-Jxxx-001 003 Software is MTEZ by Magicsoft. And by the way
  4739. I ran into a small problem. I can't seem to send faxes reliably with the CLASS2
  4740. driver even though I have been able to send before. The problems seem
  4741. intermitant. I put my COMPUCOM (out of business) back in service and no more
  4742. problems ! Leave me a voice message @ (816)221-2661 if you've ANY ideas. Thanx
  4743.  
  4744.  
  4745. Msg#: 1017 *MODEM*
  4746. 06-20-92 20:26:57
  4747. From: MARK WHITE
  4748.   To: KEITH SITTER (Rcvd)
  4749. Subj: REPLY TO MSG# 934 (FAX)
  4750. You need the new rom.  Pls EMail your address and I will get it sent to you.
  4751.  
  4752. Mark - Supra TEch Support
  4753.  
  4754.  
  4755. Msg#: 1147 *MODEM*
  4756. 06-23-92 06:29:27
  4757. From: KEITH SITTER
  4758.   To: MARK WHITE (Rcvd)
  4759. Subj: REPLY TO MSG# 1017 (FAX)
  4760. Thanks for the quick response but I just got the new roms in the mail yesterday
  4761. (Monday 6/22/92). Iwas wondering however if there is any software out there
  4762. that will allow auto discriminate mode on these modems so I wouldn't need one
  4763. for fax and one for data (inbound) ? Any ideas would be appreciated. Thanks
  4764. again, Keith
  4765.  
  4766.  
  4767. Msg#: 1204 *MODEM*
  4768. 06-25-92 01:33:41
  4769. From: MARK WHITE
  4770.   To: KEITH SITTER
  4771. Subj: REPLY TO MSG# 1147 (FAX)
  4772. The mid-july ROM will allow the adaptive answer to work correctly.  I do know
  4773. that there is some front door and BBS software which will allow a single modem
  4774. to do both jobs.
  4775.  
  4776. Mark - Supra Tech Support
  4777.  
  4778.  
  4779. Msg#:  689 *MODEM*
  4780. 06-12-92 07:57:15
  4781. From: MICHAEL L. LEE
  4782.   To: SYSOP (Rcvd)
  4783. Subj: V.32BIS ROM UPGRADE
  4784. Hello I see by reading the messages that your collecting names for a list on
  4785. the upcoming ROM upgrade for the V.32bis Supra modem.  Please accept my name
  4786. and address:  Michael L. Lee, 8099 Counselor Road, Manassas, Virginia 22111.  I
  4787. have sent in my registration and you should be able to cross reference this
  4788. information.  On another subject, I am a member of the Capital Area SysOps
  4789. Association in Washington, DC.  We are a group of Washington are SysOps who
  4790. meet the second Saturday of each month.  We have had a number of visiting guest
  4791. speakers such as Mr. James Summers, Director of SysOp Sales for US Robotics and
  4792. on June 13th (tomorrow) we are haveing an IBM representative make a
  4793. presentation on OS/2.  The reason I bring this up is would there be any one at
  4794. Supra Corporation that would be interested in coming to Washington and
  4795. addressing our group?  At the las t meeting there was quite a discussion
  4796. regarding Supra modems for BBS usage.  Our go  group would be a very nice forum
  4797. for your sales group.  There are somewhere in the neighbor hood of 3,000 bbes
  4798. in the Washington area.  CASA has a membership of about 150.  I thin you would
  4799. receive a nice welcome .  You can adet a nice reception here in
  4800. Washington.Please leave a respone to me here on your board or call 202-267-5697
  4801. (the FFA's BBS and leave me a message there.  Supra is registered caller on
  4802. this board.  Thanks!I look forward to hearing from you.
  4803.  
  4804.  
  4805.  g
  4806.  
  4807.  
  4808. Msg#: 1102 *MODEM*
  4809. 06-22-92 13:20:10
  4810. From: SYSOP
  4811.   To: MICHAEL L. LEE (Rcvd)
  4812. Subj: REPLY TO MSG# 689 (V.32BIS ROM UPGRADE)
  4813. I have written down your name.  Actually, the list is just to make sure that
  4814. people get the chips.  They will be sent out automatically to all registered
  4815. users in mid-July, free of charge.  I have also passed your invitation on to
  4816. the Sales Manager. Thank you for the invitation.  If you have any more
  4817. questions, please let me know. [Nathan]  Supra Technical Support
  4818.  
  4819.  
  4820. Msg#: 1170 *MODEM*
  4821. 06-24-92 05:08:32
  4822. From: MICHAEL L. LEE
  4823.   To: SYSOP
  4824. Subj: REPLY TO MSG# 1102 (V.32BIS ROM UPGRADE)
  4825. Thanks Nathan.  Our SysOp group would be very please to sponsor your sales
  4826. manager at one of our meetings.  We meet on the 2nd Saturday of each month
  4827. alternating between Northern Virginia (Springfield) and Rockville, Maryland.
  4828. Depending on when your sales manager would be coming we could let you know
  4829. whether we're meeting in Maryland or Virginia for that date.  This would assist
  4830. him in making his travel arangements.  As a member of the Capital Area SysOps
  4831. Association, I appreciate your (and Supra's) interest in joining us one
  4832. saturday in the future!
  4833.                                                                          Mike
  4834. ;-)
  4835.  
  4836.  
  4837.  
  4838.  
  4839. Msg#:  692 *MODEM*
  4840. 06-12-92 08:57:18
  4841. From: GRIER ELLIS
  4842.   To: SYSOP (Rcvd)
  4843. Subj: BUSY RESET
  4844. My new Supra v.32bis modem sometimes does a soft reset (like ATZ) when it
  4845. receives a busy signal.  When this occurs, the COMM program receives no
  4846. notification.  I am using AT&F2M0 as my init string.  Any suggestions?
  4847. . BTW, I have played with many modems in my role supporting several hundred
  4848. client offices, and I love the Supra v.32bis.  I am  recommending that we order
  4849. a couple to test more thoroughly (mine is my personal modem - actually my
  4850. second personal modem, the other is a USR HST 14400) so that we can possibly
  4851. recommend (or resell) to our clients.
  4852. . Also, BTW, I think that you guys in tech support are doing a great job no
  4853. matter what some callers say (and anyone who doesn't expect back-ordering of a
  4854. product at the Supra v.32bis's price/performance level is not in touch with
  4855. reality).  Keep up the good work! Grier
  4856.  
  4857.  
  4858. Msg#:  750 *MODEM*
  4859. 06-13-92 12:36:31
  4860. From: MARK WHITE
  4861.   To: GRIER ELLIS (Rcvd)
  4862. Subj: REPLY TO MSG# 692 (BUSY RESET)
  4863. What is the serial number of the modem?  Thanks.
  4864.  
  4865. Mark - Supra Tech Support
  4866.  
  4867.  
  4868. Msg#:  865 *MODEM*
  4869. 06-16-92 09:04:17
  4870. From: GRIER ELLIS
  4871.   To: MARK WHITE (Rcvd)
  4872. Subj: REPLY TO MSG# 750 (BUSY RESET)
  4873. Mark, The serial # of my modem is 14E005930. Thanks, Grier
  4874.  
  4875.  
  4876. Msg#:  926 *MODEM*
  4877. 06-17-92 18:48:40
  4878. From: MARK WHITE
  4879.   To: GRIER ELLIS (Rcvd)
  4880. Subj: REPLY TO MSG# 865 (BUSY RESET)
  4881. It sounds like a problem with that particular modem.  If you can contact Tech
  4882. support we can get the modem exchanged for you.
  4883.  
  4884. Mark - Supra Tech Support
  4885.  
  4886.  
  4887. Msg#: 1022 *MODEM*
  4888. 06-20-92 21:19:44
  4889. From: GRIER ELLIS
  4890.   To: MARK WHITE (Rcvd)
  4891. Subj: REPLY TO MSG# 926 (BUSY RESET)
  4892. Thanks, Mark. I'll try to get Tech Support on the line. Any idea how long
  4893. replacement will take? Grier
  4894.  
  4895.  
  4896. Msg#: 1027 *MODEM*
  4897. 06-20-92 22:13:43
  4898. From: MARK WHITE
  4899.   To: GRIER ELLIS
  4900. Subj: REPLY TO MSG# 1022 (BUSY RESET)
  4901. With our FedEx program, you should be able to have one out to you in a few
  4902. days.
  4903.  
  4904. Mark - Supra Tech Support
  4905.  
  4906.  
  4907. Msg#:  720 *MODEM*
  4908. 06-13-92 00:03:25
  4909. From: ANDREW ELDRITCH
  4910.   To: ALL
  4911. Subj: DUAL STANDARD HST'S & 14.4
  4912. what are the proper settings for connecting with Dual Standard HSTs at 14.4?
  4913. if there are some settings that might not be correctly set on the HST, what
  4914. should a person tell the sysop of such a BBS to do?
  4915.  
  4916. ae
  4917.  
  4918.  
  4919. Msg#:  751 *MODEM*
  4920. 06-13-92 12:39:10
  4921. From: MARK WHITE
  4922.   To: ANDREW ELDRITCH
  4923. Subj: REPLY TO MSG# 720 (DUAL STANDARD HST'S & 14.4)
  4924. What kind of problem do you have when connectiong.  If you are connecting at
  4925. 2400, then the DS is stet to answer high speed with HST protocols only.  Other
  4926. wise, you just need to set the modem to &F2.
  4927.  
  4928. Mark - Supra Tech Support
  4929.  
  4930.  
  4931. Msg#:  792 *MODEM*
  4932. 06-15-92 05:34:14
  4933. From: SCOTT PIERCY
  4934.   To: MARK WHITE (Rcvd)
  4935. Subj: REPLY TO MSG# 751 (DUAL STANDARD HST'S & 14.4)
  4936. there are some USR Duals out there that have older firmware & thus will not
  4937. reliably connect with the SupraFax v.32bis & a few other v.32bis modems of
  4938. recent manufacture, most notably the Hayes Ultra 14.4. This is just from my
  4939. personal experiences, but I have had the problem substantiated by some BBS
  4940. SYSOPS who are running older Duals, so this may be the case here. Out of 30 or
  4941. so DS boards I've called since I got my SupraFax, I've only experienced
  4942. problems with two, and both of these had (relatively) old Dual Standards. Hope
  4943. this helps.. Scott Piercy
  4944.  
  4945.  
  4946. Msg#:  924 *MODEM*
  4947. 06-17-92 18:41:56
  4948. From: MARK WHITE
  4949.   To: SCOTT PIERCY (Rcvd)
  4950. Subj: REPLY TO MSG# 792 (DUAL STANDARD HST'S & 14.4)
  4951. Thanks for the info.  That is one of the unknowns which can make high speed
  4952. connections frustrating.
  4953.  
  4954. Mark - Supra Tech Support
  4955.  
  4956.  
  4957. Msg#:  726 *MODEM*
  4958. 06-13-92 05:38:48
  4959. From: CARLOS CARDOSO
  4960.   To: SUPRA
  4961. Subj: SUPRA MODEM
  4962. I have a suprafaxmodem V32bis and i have noise line problems to comm. to usa, i
  4963. use qmodem 5.0, which is the best configuration fo noise (handling noise
  4964. problems)? thanks
  4965.  
  4966.  
  4967.  
  4968.  
  4969.  
  4970. Msg#:  728 *MODEM*
  4971. 06-13-92 08:49:20
  4972. From: URBAN LARSSON
  4973.   To: ALLEN JOHNSON (Rcvd)
  4974. Subj: INIT STRING
  4975. Hi Allen, I just wanted to mention to You that your init string doesn't work.
  4976. You have to realize that when the modem sees the ATZ0 command it immediatly
  4977. does a reset. During reset the modem cannot accept any commands,  so the rest
  4978. of your init string is lost. Put some delay commands like ,,,, or whatever the
  4979. COMMO software uses as delay, between the ATZ0 and the rest of the line so the
  4980. modem have time to settle down after reset and accept the rest of the init
  4981. string.  Or maybe store the wanted setting with AT&W0 and just do the ATZ0 in
  4982. the init string, as this is probably the setting You are using most of the time
  4983. anyway.
  4984.  
  4985.  
  4986. A small note from:    
  4987.  
  4988. Urban Larsson, Stockholm, Sweden
  4989.  
  4990.  
  4991.  
  4992. Msg#:  774 *MODEM*
  4993. 06-14-92 14:20:37
  4994. From: ALLEN JOHNSON
  4995.   To: URBAN LARSSON (Rcvd)
  4996. Subj: REPLY TO MSG# 728 (INIT STRING)
  4997. Thanks for the info. I'll check into what you say, though I must comment that
  4998. there is a board local to me that leaves MNP5 enabled and since I placed the
  4999. %C0 in my init string I have quit getting MNP5 connections. I place those
  5000. commands in my init string because I want /N3 etc set and  it is my
  5001. understandin (flawed perhaps) that the modem will not store the settings, at
  5002. least, it will not display them with AT&V (which displays the NRAM settings). 
  5003.  
  5004.  
  5005. Msg#:  777 *MODEM*
  5006. 06-14-92 14:41:49
  5007. From: URBAN LARSSON
  5008.   To: ALLEN JOHNSON (Rcvd)
  5009. Subj: REPLY TO MSG# 774 (INIT STRING)
  5010. The commands you mention is all stored in the ram with the bitmap registers. So
  5011. it shouldn't be necesary to execute them each time you turn the modem on.
  5012.   You can have a look in the manual to see have the bitmap registers are used.
  5013. Regards Urban Larsson
  5014.  
  5015.  
  5016.  
  5017. Msg#:  928 *MODEM*
  5018. 06-17-92 21:46:53
  5019. From: ALLEN JOHNSON
  5020.   To: URBAN LARSSON (Rcvd)
  5021. Subj: REPLY TO MSG# 777 (INIT STRING)
  5022. You mean that I can set the bitmap registers or that by using those commands I
  5023. set the registers? I hope the former as that will clear up any difficulties I
  5024. have (and also explain why you are RIGHT <GRIN>).
  5025.  
  5026.  
  5027. Msg#:  940 *MODEM*
  5028. 06-18-92 10:01:42
  5029. From: URBAN LARSSON
  5030.   To: ALLEN JOHNSON (Rcvd)
  5031. Subj: REPLY TO MSG# 928 (INIT STRING)
  5032. Hi allen, yes you can set the things with either the % command or whatever or
  5033. by setting the bit in the corresponding S register. Just be sure to read the
  5034. not shown S registers and note them down for future referens if they are
  5035. altered by mistake or other reson.
  5036.                                                           Regards  Urban 
  5037.  
  5038.  
  5039. Msg#: 1133 *MODEM*
  5040. 06-22-92 19:16:26
  5041. From: ALLEN JOHNSON
  5042.   To: URBAN LARSSON (Rcvd)
  5043. Subj: REPLY TO MSG# 940 (INIT STRING)
  5044. Thank you for the reply. Since your first message, I undertook the advice you
  5045. gave me and now have only to report that it works very nicely. Thank you for
  5046. the advice. My initialization string is now ATZ0.
  5047.  
  5048.  
  5049. Msg#:  729 *MODEM*
  5050. 06-13-92 09:01:48
  5051. From: URBAN LARSSON
  5052.   To: SYSOP (Rcvd)
  5053. Subj: ROM UPGRADE
  5054. My adress for the ROM upgrade is:
  5055.  
  5056. MOTOROLA AB LMPS, Urban Larsson Box 2005, S-127 02 Skarholmen
  5057.           SWEDEN
  5058.  
  5059.  
  5060.  
  5061.  
  5062.  
  5063. Msg#: 1113 *MODEM*
  5064. 06-22-92 14:23:18
  5065. From: SYSOP
  5066.   To: URBAN LARSSON (Rcvd)
  5067. Subj: REPLY TO MSG# 729 (ROM UPGRADE)
  5068. OK.  You're on the list. [Nathan]
  5069.  
  5070.  
  5071. Msg#:  731 *MODEM*
  5072. 06-13-92 09:21:54
  5073. From: JOE STEWART
  5074.   To: ALL-SYSOP
  5075. Subj: ATNS37= SETTINGS...
  5076. GoodMorning.... i am looking for a way to lockmy modem at 12000 due to ALL the
  5077. line noice in the St. Louis area.... i am a SysOp (HO's HOUSE BBS Fido
  5078. 1:100/630) and for all the mail runs that my modem makes i need to have it set
  5079. lower then 14.4 other wise it just runns up the phone bill with short calls....
  5080. i am looking for a way to have it that it lock it BUT that users with slower
  5081. then 12000 can still log on with the s37 setting only that speed modem can get
  5082. on..... is there a way to set it that it will do that and slower........ ie
  5083. 2400... if so PLEASE help..... LaTeR...joe (HO's HOUSE BBS (314) 272-6535 Fido
  5084. 1:100/630)
  5085.  
  5086.  
  5087. Msg#:  752 *MODEM*
  5088. 06-13-92 12:41:17
  5089. From: MARK WHITE
  5090.   To: JOE STEWART
  5091. Subj: REPLY TO MSG# 731 (ATNS37= SETTINGS...)
  5092. Whith <rom v1.200C that is not possible.  1.200C impelments S110 which allows
  5093. you to specify what baud rates to allow.
  5094.  
  5095. Mark - Supra Tech Support
  5096.  
  5097.  
  5098. Msg#:  742 *MODEM*
  5099. 06-13-92 11:46:58
  5100. From: URBAN LARSSON
  5101.   To: ALL
  5102. Subj: PROBLEMS CONNECTING?
  5103. I wanted to mention that I have no problem to connect with other modems at
  5104. 14400, even supra modems. As there seems to be people having problem with this,
  5105. (connecting to Rusty'n Edies BBS is mentioned) I present my config of the supra
  5106. v32bis. Maybe there is only one or two parameters in my setup that fixes the
  5107. problem, but I haven't tested which one.
  5108.  
  5109. If bad telephone lines is noticed, then redialing often is the solution, as you
  5110. often get another trunk line with lesser noice (or more) from the telephone
  5111. company. I think this is what happens with Supra corps BBS. If you use the M3
  5112. command, it is possible to hear the line noice level when the modem waits for
  5113. answer, even if the tiny loadspeaker doesn't help much,(HST's have an excelent
  5114. loadspeaker for this) and redial when the noice is notisable. If that doesn't
  5115. help, put N0 in the dialing prefix on those telephone numbers that have bad
  5116. lines. This command set the modem to max 9600bps connection. I haven't seen any
  5117. BBS not accepting this, even under worst line conditions. Also put N1 in the  
  5118. other numbers prefix that you want highest connect rate with.
  5119.  
  5120. You have to remember that V32bis almost take up twice the spectrum energi of
  5121. the line compared with HST 14400 (and new 16800 ) and is therefore much more
  5122. sensitive to line quality. So don't compare  V32bis with HST 14400 connections.
  5123. Also most of the DualStandard HST out is only V32 9600 modems.
  5124.  
  5125.  
  5126. Last word about communication software. Keep DOS and software buffers at a low
  5127. value, like DOS buffers=20 and software at 2-4 Kb, otherwise filetransmissions
  5128. often get CRC and BAD SUBPACKET errors when writing to disk. And remember to
  5129. disable or remove disk-caching before starting the comm software, or you will
  5130. surely get errors during file receiving.
  5131.  
  5132. Telix software seems to have a bug or something similar, if screenwrite is
  5133. slower than modem throughput, (often happens when looking at scrolling 
  5134. filelistings using V42bis) then DTR is dropped by Telix. So don't use the DROP
  5135. DTR TO HANGUP command in the setup, and always use CTS RTS handshake.
  5136.  
  5137.  
  5138. Heres my setup also with the important S registers not shown with AT&V. It will
  5139. give a locked computer-modem link at 38400 and modem responds with modem-modem
  5140. connect rate and protocols. It will start with V32bis and V42bis and go down
  5141. from there until it matches the capabilitys of the other modem.
  5142.  
  5143. I guess that the important parameters being:
  5144.  
  5145. W2 &K3 &Q9    S23:063 S36:003 S37:009 S41:019 S46:138 S48:007 S95:043
  5146.  
  5147.  
  5148. ACTIVE PROFILE: B1 E1 L1 M3 N1 Q0 T V1 W2 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q9 &R0 &S0
  5149. &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:050
  5150. S08:002 S09:006 S10:014 S11:060 S12:050 S18:000 S25:005 S26:001 S36:003 S37:009
  5151. S38:020 S44:003 S46:138 S48:007 S49:008 S50:255
  5152.  
  5153.  
  5154. S13:095 S14:139 S15:000 S16:000 S20:000 S21:048 S22:125 S23:063  S24:000
  5155. S27:129 S40:087 S41:019 S82:128 S86:255 S95:043
  5156.  
  5157.  
  5158.  
  5159. I hope someone will correct me if I made any errors. 
  5160.               
  5161.                                               Bye...      Urban Larsson     
  5162.                                                               Sweden
  5163.  
  5164.  
  5165.  
  5166. Msg#:  761 *MODEM*
  5167. 06-13-92 18:53:04
  5168. From: MITCHELL SASH
  5169.   To: SYSOP (Rcvd)
  5170. Subj: V32BIS BUGS
  5171. I waswiondering if you have a mailreader program that is available on this
  5172. board to speed through the messages when calling long distance....It would
  5173. greatly cut down on the phone bills  Thanks Mitch
  5174.  
  5175. I wa
  5176.  
  5177.  
  5178. Msg#:  838 *MODEM*
  5179. 06-15-92 19:03:52
  5180. From: BRETT FRYMIRE
  5181.   To: CHRIS HUFNAGEL
  5182. Subj: REPLY TO MSG# 40 (V32BIS BUGS)
  5183. This has been very informative for me!  I was having a VERY difficult time with
  5184. other brands of v.32bis connecting but no problems with 9600 as has been
  5185. indicated by the other messages.  I see the problem is the fall back. An
  5186. interesting experiment i tried was to cycle power in the Supra and it would
  5187. connect.  ????  Don't ask me.  :-)  Otherwise I like the Supra.  Thought I am
  5188. VERY interested in the ROM upgrade! Later 
  5189. -- Brett
  5190.  
  5191.  
  5192. Msg#:  762 *MODEM*
  5193. 06-13-92 18:57:40
  5194. From: MITCHELL SASH
  5195.   To: SYSOP (Rcvd)
  5196. Subj: MAILREADER
  5197. I am trying to find out how to use this board so please be patient...My
  5198. original message was dealing with using a mailreader program such as Tomcat or
  5199. Qmail to make reading the nmessages easier...If you do have it hoew do you
  5200. acxcess it 
  5201.  
  5202. Thanks MITCHm
  5203.  
  5204.  
  5205. Msg#: 1115 *MODEM*
  5206. 06-22-92 14:28:49
  5207. From: SYSOP
  5208.   To: MITCHELL SASH
  5209. Subj: REPLY TO MSG# 762 (MAILREADER)
  5210. We don't have a mail reader system.  We don't expect for people to be on long
  5211. enough for it to merit this sort of system.  Please feel free to brouse around,
  5212. and DL anything you like. [Nathan]  Supra Technical Support
  5213.  
  5214.  
  5215. Msg#: 1167 *MODEM*
  5216. 06-23-92 23:29:30
  5217. From: DARRELL SANDERSON
  5218.   To: SYSOP
  5219. Subj: REPLY TO MSG# 1115 (MAILREADER)
  5220. You may not expect people to be on long enough ... but at long distance rates,
  5221. costs add up.  This board is rich in technical information and it should be
  5222. easier to get it.   Is it possible to zip up the message databases for
  5223. downloading as an alternative???  It would be much appreciated.  Thank you.
  5224. CANADA
  5225.  
  5226.  
  5227. Msg#:  770 *MODEM*
  5228. 06-14-92 08:57:24
  5229. From: JOHN TROHER
  5230.   To: MATT ZUKOWSKI
  5231. Subj: SUPRA TO USR DUAL
  5232. I'm using Procomm Plus and have tried everything including your sugestions I
  5233. cannot connect to any USR 9600 or 14.4 modem at anything higher than 2400
  5234. anymore suggestions???
  5235.  
  5236.  
  5237.  
  5238. Msg#:  772 *MODEM*
  5239. 06-14-92 12:04:47
  5240. From: IRA BRICKMAN
  5241.   To: MARK WHITE (Rcvd)
  5242. Subj: V32BIS FAXMODEM
  5243. Mark, 
  5244.  
  5245. I've read all the messages and I can't keep quiet any longer!
  5246.  
  5247. Like so many of your callers, I, too, was concerned that my v.32bis FaxModem
  5248. wasn't simply "plug 'n play."  I even wrote to SUPRATECH on GEnie (Nathan, I
  5249. guess) expressing concern.  Concern, not outrage, not accusa-
  5250. tions, and certainly not malice, as I've read in some of the messages here.
  5251.  
  5252. It seems to me that you are in the midst of learning a great customer service
  5253. (and PR) lesson: it ain't enuff to have all (or most) of the facts and be able
  5254. to expound on them.  You have to hear what's important to your customers and
  5255. give it to them.
  5256.  
  5257. What the gripers really want for their $$$ is the "plug 'n play" they're used
  5258. to at lower bps rates.  They've forgotten about the learning curves of their
  5259. past that were forced on them with each new venture into techdom. That learning
  5260. curve applies no only to your customers, but to you and Nathan, as well.  After
  5261. all these are new chip sets with new firmware for (relatively) new standards.
  5262.  
  5263. I finally met with success thanks to the messages here from you and Nathan, and
  5264. for the &Q9 tip from one of the users.  I logged onto my friend's BBS (it also
  5265. uses a Supra 14.4) at 14,400(!) instead of the smooth-running, s37=9, ATN, 9600
  5266. I had been using.
  5267.  
  5268. To your unhappy, unhearing customers:
  5269.  
  5270. Guess what, guys! The connection >often< paused to wait for the line noise. It
  5271. doesn't do that at 9600 bps.  I did download at 1600+ for the first time
  5272. (yes!!).  But I now know that it also could be that I was on at 12.2 or lower.
  5273. Why?..... 
  5274.  
  5275. Here's the punch line:
  5276.  
  5277. I couldn't get my uploading to work.  It halted, and repositioned, several 
  5278. times, tried various cps rates and, about halfway through, timed out with too
  5279. many errors.  So I called back at 9600 using the s37 switch and N0 commands,
  5280. but left the &Q9 in place.  My upload went through at a steady 1910 cps!!!! The
  5281. fastest to date anywhere!
  5282.  
  5283. And, read my lips, at 9600 baud connect!!!
  5284.  
  5285. As you've been trying to say, Mark: those connect and carrier messages aren't
  5286. as important as they used to be.  It's the true throughput rate that counts.
  5287.  
  5288. So, Mark, Nathan, thanks for the BBS, and for leaving even the worst of the
  5289. messages up for reading.  To those of you who are so worried that you are being
  5290. ripped off, you should be more frustrated at yourselves for not being willing
  5291. to listen and learn.
  5292.  
  5293. For those of you who are, here is my ROM version:
  5294.  
  5295. V1.000-E TR14-Jxxx-001 003
  5296.  
  5297. Here were my settings for the 9600 "baud", 1900+ cps transfer:
  5298.  
  5299. ACTIVE PROFILE: B1 E1 L2 M1 N0 Q0 T V1 W1 X4 Y0 &C0 &D2 &G0 &J0 &K3 &Q9 &R0 &S0
  5300. &T4 &X0 &Y0 S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:050
  5301. S08:001 S09:006 S10:014 S11:050 S12:050 S18:000 S25:005 S26:001 S36:007 S37:009
  5302. S38:020 S44:003 S46:138 S48:007 S49:008 S50:255 
  5303.  
  5304. (In case someone notices, I've got to keep my DCD line high to use some of my
  5305. term program's features)
  5306.  
  5307. There are also some excellent, readable text files out there explaining more
  5308. about these standards, proprietary protocols, and modemming in general.  These
  5309. are much better than the speculation of disgruntled users.
  5310.  
  5311. Nathan, I sent in my registration card, but, what the hey, put me on the list,
  5312. too.  Better yet, just look to see if I'm on it already!
  5313.  
  5314. Could you please post an errata sheet to supplement the manual?  It would be a
  5315. big help.  Thanks.
  5316.  
  5317. Ira
  5318.  
  5319.  
  5320. Msg#:  920 *MODEM*
  5321. 06-17-92 18:30:35
  5322. From: MARK WHITE
  5323.   To: IRA BRICKMAN (Rcvd)
  5324. Subj: REPLY TO MSG# 772 (V32BIS FAXMODEM)
  5325. Thanks for the kind words and reports of your eventual success.  We are working
  5326. on addendiums.  One of them is V32_Q&A.TXT in the MODEM dled section.  I will
  5327. be getting the latest version of that up here in about a week and a half from
  5328. now. 
  5329.  
  5330. Mark - Supra Tech Support
  5331.  
  5332.  
  5333. Msg#:  778 *MODEM*
  5334. 06-14-92 14:43:00
  5335. From: URBAN LARSSON
  5336.   To: JASON SLATER
  5337. Subj: PD BBS
  5338. Hi Jason, I tried that PD BBS you mentioned, the Maverick BBS. No problem
  5339. connecting 14400 LAPM V42bis from Sweden. Have you seen my message here on this
  5340. BBS regarding setup of modem? Maybe that will help you a bit on the way.
  5341.                                             
  5342.                                             Regards  Urban Larsson
  5343.  
  5344. B.T.W.  You wheren't registred under Your name in Maverick BBS.
  5345.  
  5346.  
  5347.  
  5348.  
  5349. Msg#:  779 *MODEM*
  5350. 06-14-92 14:43:44
  5351. From: URBAN LARSSON
  5352.   To: PORT (Rcvd)
  5353. Subj: PACKET RADIO BBS
  5354. I'v tried that packet radio BBS you had problem with. I connected there 5 times
  5355. out of 5 with 14400 LAPM V42bis. Maybe my message here on the Supra BBS
  5356. explaining the setup of my modem can help you somewhat?  
  5357.                        
  5358.                            Regards   Urban Larsson,Sweden
  5359.  
  5360.  
  5361.  
  5362. Msg#:  851 *MODEM*
  5363. 06-16-92 03:42:00
  5364. From: PORT
  5365.   To: URBAN LARSSON (Rcvd)
  5366. Subj: REPLY TO MSG# 779 (PACKET RADIO BBS)
  5367. Thanks Urban : I have been able to connect at 9600 now reliable, but not at
  5368. 14400? My line here is very noisey and brings a 015 to 023 with  the %q command
  5369. and about  022 for the level %L ... 
  5370.                                                          Port..
  5371.  
  5372.  
  5373. Msg#:  780 *MODEM*
  5374. 06-14-92 16:11:12
  5375. From: B.J. GUILLOT
  5376.   To: SYSOP (Rcvd)
  5377. Subj: NEW ROMS
  5378. I would also like to receive any new chips when they are available. I sent my
  5379. registration card off two weeks ago, so you should have it by now.
  5380. Information:
  5381.  
  5382. B.J. Guillot 2611 Rushwood Circle Houston, Texas 77067-1941
  5383.  
  5384. Modem serial number 14E 002343
  5385.  
  5386.  
  5387. Msg#: 1121 *MODEM*
  5388. 06-22-92 15:01:20
  5389. From: SYSOP
  5390.   To: B.J. GUILLOT (Rcvd)
  5391. Subj: REPLY TO MSG# 780 (NEW ROMS)
  5392. OK.  Your on the list.  Please be sure to also send in your registration card. 
  5393. [Nathan]  Supra Techncial Support
  5394.  
  5395.  
  5396. Msg#:  783 *MODEM*
  5397. 06-14-92 20:01:15
  5398. From: JONATHAN GREENBERG
  5399.   To: MARK WHITE (Rcvd)
  5400. Subj: MODEM PROBLEMS
  5401. First of all, I appreciate the effort you guys are making to procuce a product
  5402. that is so critical to outside influences that you can't do much about except
  5403. take the heat.  But it is frustrating to have to dial repeatedly to get a
  5404. decent connection.  But once I get one, it's great.
  5405.  
  5406. I've got two problems for you.  I received my SupraFAXmodem V.32bis S/N 
  5407. 14E000765 from Computability the beginning of April.  With it I received WinFAX
  5408. 2.0.  Is this the same software you are shipping now?  I have had FAX
  5409. transmission problems since I received the modem.  In particular, there is one
  5410. fax I have been completely unable to connect to.  I made the recommended
  5411. changes, but have had no luck.  I reported my problems to tech services by
  5412. voice, the early version of this BBS, and by FAX.  Should I have received the
  5413. first issue of the new ROM?  My current ROM printout with I3 shows V1.000-C
  5414. TR14-Jxxx-001 110.  You should have gotten my registration card months ago.  I
  5415. certainly want to get the new ROM when it's available.
  5416.  
  5417. Second problem - yesterday my speaker died in the middle of a dial session. The
  5418. dialing continued, but I couldn't hear anything.  No tones, no ringing signal,
  5419. no carrier - nothing.  After that, the only noise was a click at the start of
  5420. each session.  I turned it off for a few minutes; when I turned it on again it
  5421. worked for about five minutes and then died again.  I took the modem out of its
  5422. case and tried it.  The speaker had separated from the little IC chip it's
  5423. taped to, but it worked all right.  Is this a heat-related problem?  It seems
  5424. to get pretty hot inside the case.  Any advice?  I don't mind sending the modem
  5425. back if I have to, although I've gotten pretty spoiled by those 1700 cps
  5426. transfers.
  5427.  
  5428.  
  5429.  
  5430. Msg#:  921 *MODEM*
  5431. 06-17-92 18:36:25
  5432. From: MARK WHITE
  5433.   To: JONATHAN GREENBERG (Rcvd)
  5434. Subj: REPLY TO MSG# 783 (MODEM PROBLEMS)
  5435. I do have you on my list for fax rom upgrade.  I sent the list back to shipping
  5436. at the beginning of the week.
  5437.  
  5438. You can return the modem to us for repair of the speaker.  We do have an
  5439. exchange program that if we can get a Visa / MasterCard #, in a few days we
  5440. will UPS Red Lable a new modem to you.  In the packaging is a return envelope
  5441. (FedEx) for the old modem.  The shipping is on us and we do not charge the
  5442. credit card unless we do not get the old modem back in a few weeks.  Either
  5443. leave EMail to me with the pertaint info, or call our tech support hot line.
  5444. If you have had problems calling before, give it a try now, we have all of our
  5445. staff full time now and have significantly increased our call load.
  5446.  
  5447. Mark - Supra Tech Support
  5448.  
  5449.  
  5450. Msg#:  784 *MODEM*
  5451. 06-14-92 20:25:32
  5452. From: JONATHAN GREENBERG
  5453.   To: MARK WHITE (Rcvd)
  5454. Subj: SPEAKER PROBLEM
  5455. More info on my speaker problem - now it doesn't work at all, either inside or
  5456. outside the case.  Help!!
  5457.  
  5458.  
  5459. Msg#:  788 *MODEM*
  5460. 06-14-92 23:49:29
  5461. From: JOHN T KOHL
  5462.   To: SYSOP (Rcvd)
  5463. Subj: RE: CURRENT REVS/NEW ROMS?
  5464. re: msg #499 in modems area.  I haven't heard a thing back on this (>1 week
  5465. later!)
  5466.  
  5467.  
  5468. Msg#:  793 *MODEM*
  5469. 06-15-92 05:47:37
  5470. From: JASON PIA
  5471.   To: MARK WHITE (Rcvd)
  5472. Subj: NEW ROMS
  5473. Good and bad news! To all those having problems with faxing and Winfax Pro -
  5474. the new  ROMS cure this problem (the software fixes did not work for me  
  5475. either!) BUT with the new ROMs I have a new problem! When I dial other modems  
  5476. and get a ringing tone the modem reports this as BUSY and hangs  up - very
  5477. useful. Does this have naything to do with message 748?  This problem is
  5478. deeeply frustrating. I can only get on to this board because the modem answers
  5479. immediately. Please bare in mind that the BBs that I am trying are in the UK
  5480. and our tones may differ? I would be grateful if you can suggest any setup
  5481. changes that may  help or am I in big trouble?! TTFN, Jason
  5482.  
  5483.  
  5484. Msg#:  830 *MODEM*
  5485. 06-15-92 11:38:26
  5486. From: URBAN LARSSON
  5487.   To: ALL
  5488. Subj: PROBLEM CONNECTING?-PART TWO
  5489.    Just a few points that I come to think of now, that maybe could be 
  5490.    of use to somebody else.
  5491.  
  5492.  
  5493. 1. Always lock the terminal/BBS software at a fixed bps rate, like
  5494.    38400bps or higher (but you probably need the 16550 chip at 57600)
  5495.    and of course also lock the modem link rate at the same speed. 
  5496.    Don't use autobaud detect and similar features in the software.
  5497.    That way you don't have to bother with what rate the connection
  5498.    is done. (Some softwares have problem detecting the right BPS rate,
  5499.    most often 1200 and 12000bps and sometimes doesn't have 12000 at all)
  5500.    You will never again have to see the screenfulls of garbled text again.
  5501.    And most important, the throughput have a chance of comming up to
  5502.    1650bps with Zmodem and 1700 with Ymodem-G. With already compressed
  5503.    files that is, like ZIP and DMS...Haven't seen any BBS yet that's not 
  5504.    compressing their files  (Maybe excluding Genie, The Source and 
  5505.    some others?).  With V42bis compressing on and transfering textfiles, 
  5506.    you easily come up to that 38000 bps that everybody likes to tell about 
  5507.    but no one uses in practice. Error correcting protocols are more 
  5508.    important, like LAPM.)
  5509.  
  5510. 2. Never hog the BBS's by reading and writing long messages online.
  5511.    Try to keep the BBS's free to other users and keep the phonebill down.
  5512.    On this BBS you just set the "capture on" in your terminal software
  5513.    and state that you want to "read all new messages, board by board".
  5514.    Also use the "always follow" to see the replay on the messages and
  5515.    set read to nonstop mode. When the scrolling stops, log off from 
  5516.    the BBS and read the capture file with your favorite wordprocessor, 
  5517.    that ofcourse have search and find features and other helpful things, 
  5518.    without having to see the dollars and cents increasing on your phonebill 
  5519.    with each minute you stay online. Another benefit is that you create 
  5520.    your reply off line with the same wordprocessor and upload the message 
  5521.    into the fullscreen editor with ASCII protocol. You never again have to 
  5522.    deal with that ugly fullscreen editor that won't show you how the message 
  5523.    will look like until you save it.
  5524.    No need to use fancy mailreding programs on small BBS's like this one.
  5525.    ( Or even big ones, as they often have options to read only mail 
  5526.     adressed to yourself or messages of general interest and so on...)
  5527.  
  5528. 3. I've tried to connect to the different BBS's that people say they have 
  5529.    problems with, but always get good connections at 14400bps.
  5530.    Try reading my message here called "#742 Problems connecting?" 
  5531.    about setting the modem up. I've tested different setups, but the one
  5532.    I'm using now seems to be working with every BBS so far.
  5533.    
  5534.    If you can't find any good terminal software, download the Telix 3.15
  5535.    (including doc's and logon script files and all) that you can find on 
  5536.    this BBS.  It's one of the better ones including all important protocols 
  5537.    like Zmodem and the most efficient one, Ymodem-G.
  5538.    
  5539.    
  5540.    
  5541.    Don't see this text as "The Law" that you must follow, it's just some
  5542.    hints that worked for me that I would like other modem users to take
  5543.    notice of and maybe use themself if it feels right. 
  5544.    As usual, if I made any mistakes, don't hesitate to correct them.
  5545.    
  5546.    B.T.W. I'm using ROM version 1.000-E if its' of any interest.
  5547.    The only (to me) annoying glitch in the V32bis fax modem so far, 
  5548.    excluding the fax features, is the not so relaible busy detect. 
  5549.    But I understand this is to be fixed in the later ROM upgrade.
  5550.    
  5551.                                        
  5552.                                        
  5553.                                        Regards  Urban Larsson, Sweden
  5554.  
  5555.  
  5556.  
  5557. Msg#:  835 *MODEM*
  5558. 06-15-92 14:06:29
  5559. From: DONALD WATSON
  5560.   To: SYSOP (Rcvd)
  5561. Subj: PULSE DIAL BUG!
  5562. OK, this will be the 6th messige a write on the same thing to you. I hope I get
  5563. a good answer for this time! Well, I owned a SupraFaxModem V32bis with a
  5564. V1.000-E  ROM release. By testing the modem I noticed an ugly bug either in the
  5565. modem's hard- or software, which I will go to show you: I have connected a
  5566. phone to the modem's phone socket. When I am dial-
  5567. ing in pulse mode with 'ATDP.....' the phone is not disconnected from time, the
  5568. modem dials and I may not pick up the phone during the dial process. This is
  5569. very ugly, because pulse dialing is the only possible way to dial here in good
  5570. old germany. Any other modem I know disconnects a to the modem connected phone
  5571. when it goes to dial. Why does only my Supra not do that, exept while tone
  5572. dialing? Can you remove this bug in the new ROM release or is it a hardware 
  5573. problem? Please test it out by yourself and give me a good answer and no
  5574. bullshit you told me before!!! Thanks. Your's Donald Watson.
  5575.  
  5576.  
  5577. Msg#:  903 *MODEM*
  5578. 06-17-92 08:00:34
  5579. From: JIMMER
  5580.   To: DONALD WATSON (Rcvd)
  5581. Subj: REPLY TO MSG# 835 (PULSE DIAL BUG!)
  5582. Just our of curiousity, why do you want to pick up the phone during the dialing
  5583. process?
  5584.  
  5585.  
  5586. Msg#:  938 *MODEM*
  5587. 06-18-92 09:43:01
  5588. From: ANTHONY DOBRE
  5589.   To: JIMMER (Rcvd)
  5590. Subj: REPLY TO MSG# 903 (PULSE DIAL BUG!)
  5591. This poor guy in Germany has a problem that no one seems to grasp. HIS
  5592. TELEPHONE BELL DINGS WHEN THE MODEM IS DIALING OUT. Just imagine! DING DING
  5593. DING DING DING DING DING DING DING DING DING over and over 50 or 60 times,
  5594. EVERY time he dials out. This is not a problem in the US but the rest of the
  5595. world may have it due to different telephone systems. The problem is DEFINITLY 
  5596. the modem, it SHOULD NOT keep the telephone active while dialing. Why can't
  5597. anyone grasp this guys problem. He was quite clear about it. WAKE UP TECHNICAL
  5598. SUPPORT and help this fellow already!
  5599.  
  5600.  
  5601. Msg#:  957 *MODEM*
  5602. 06-19-92 03:11:46
  5603. From: DAVID TOPELBERG
  5604.   To: ANTHONY DOBRE (Rcvd)
  5605. Subj: REPLY TO MSG# 938 (PULSE DIAL BUG!)
  5606. I wouldn't necesarilly blame the modem for this problem. I was born and raised
  5607. in Europe (Holland) and know of several occurences of this problem, all with
  5608. Pulse dialing phones. I was over at my grandma's last Xmas, and her phones
  5609. still ring throughout the house when you dial somewhere. Here in the US most of
  5610. us may be used to slick touch tone service, but Europe is still catching up.
  5611. (Courtesy of state owned phone companies) Anyway, my point is that is is not
  5612. necesarilly the SupraFaxModem's fault.
  5613.  
  5614.  
  5615. Msg#:  997 *MODEM*
  5616. 06-20-92 03:09:32
  5617. From: DONALD WATSON
  5618.   To: JIMMER (Rcvd)
  5619. Subj: REPLY TO MSG# 903 (PULSE DIAL BUG!)
  5620. I don't want to pick up the phone during dialing process. I am angry because my
  5621. phone (originaly by the german telecom) is always ringing, while the modem
  5622. dials. This is, because the modem doesn't disconnect the phone during dialing
  5623. in pulse mode. Please give me an answer what to do, or tell me, is this a
  5624. software bug which will be removed in the next ROM update?
  5625.  
  5626.  
  5627. Msg#:  998 *MODEM*
  5628. 06-20-92 03:11:30
  5629. From: DONALD WATSON
  5630.   To: ANTHONY DOBRE (Rcvd)
  5631. Subj: REPLY TO MSG# 938 (PULSE DIAL BUG!)
  5632. Thanks to you. I think you are the only one who correctly understand my
  5633. problem. I hope the tech supports reads your message. Donald.
  5634.  
  5635.  
  5636. Msg#: 1161 *MODEM*
  5637. 06-23-92 14:10:11
  5638. From: JIMMER
  5639.   To: DONALD WATSON (Rcvd)
  5640. Subj: REPLY TO MSG# 997 (PULSE DIAL BUG!)
  5641.    I did not understand that your problem was the ringing of the phone from
  5642. what I read in your messages.  A similar thing occurs in some phones in the US
  5643. that use the speaker as a ringer.  You hear clicking when the phoneline is
  5644. being dialed by the modem, or even another pulse dial phone.  I'm not sure it
  5645. is a "defect" in the modem, per se.  If I was having that problem I would not
  5646. plug the phone into the modem but would just plug it into the wall.  If it
  5647. still rings then, then presumably every phone in the house must ring when the
  5648. modem dials.  You could also put a switch in the phone itself to disconnect the
  5649. bell perhaps.  Other then that I'm not of much help - don't know nearly enough
  5650. about the European phone system.
  5651.  
  5652.  
  5653. Msg#:  843 *MODEM*
  5654. 06-15-92 21:05:32
  5655. From: ROBERT REISTER
  5656.   To: MARK WHITE (Rcvd)
  5657. Subj: SERIAL NUMBER REGISTRATION
  5658. Mark,
  5659.   Today I sent in my warranty registration card so I will get the ROM update in
  5660. July. However, I think I left off the serial number of the V.32bis
  5661. SupraFaxModem. The serial number of my unit is 14E008041. Please be sure to get
  5662. this information entered as I need the ROM update as soon as possible. Thank
  5663. you,
  5664.         Robert Reister
  5665.         Jenison, MI 49428
  5666.  
  5667.  
  5668. Msg#:  891 *MODEM*
  5669. 06-16-92 19:18:42
  5670. From: MICHAEL FEHRER
  5671.   To: SYSOP (Rcvd)
  5672. Subj: CLOSE-UP! & SUPRAFMODEMV32BIS
  5673. I just bought Close-up! & would like to use it with my Supfaxv32bis modem at
  5674. oone end and a Boca 14.4 v32bis modem at the other.  Neither modem is listed on
  5675. the programs chces so which modem would be a good chouice to emulate or what
  5676. initialization string should I use?  When I  place a call now I get a CARRIER
  5677. message but no CONNECT message.   Any help would be appreciated.
  5678.                   Thanks, M
  5679.  
  5680. Michael Fehrer/exit
  5681.  
  5682.  
  5683. exit
  5684. \exit
  5685.  
  5686.  
  5687.  
  5688. Msg#:  894 *MODEM*
  5689. 06-16-92 20:37:53
  5690. From: MICHAEL PAUL
  5691.   To: SYSOP
  5692. Subj: V.32BIS SPEED SHIFT
  5693. In all the name calling and stuff, I'm interested in a detail or 2.
  5694.  
  5695. What is "wrong", in that my modem and yours won't stay connected when yours
  5696. decides to initiate the downshift in speed due to noise?  Is it the old ROM in
  5697. my machine?
  5698.  
  5699. I'd think that ALL speeds would be tried (12000, 9600, 4800, 2400, etc.) before
  5700. a hang-up occurs.  I never saw more than 12000 before 300 and hangup.  Does the
  5701. new ROM try all speeds, or just "fast" ones?
  5702.  
  5703. Paraphrasing others here, my V.32bis modem is the best $280 I've ever spent.
  5704. Thanks.
  5705.  
  5706.  
  5707. Msg#:  932 *MODEM*
  5708. 06-18-92 01:40:27
  5709. From: ELVIN EMERY
  5710.   To: SYSOP
  5711. Subj: 1.2000=2.000C ??
  5712.  Is the 1.2000 ROM version the one with Fallback and everything ?? Or am I
  5713. going to have to wait for a 2.0 ver or are they both the same??
  5714.  
  5715.  
  5716. Msg#:  939 *MODEM*
  5717. 06-18-92 09:51:26
  5718. From: ANTHONY DOBRE
  5719.   To: TECHNICAL SUPPORT
  5720. Subj: PROBLEMS
  5721. I just want to say that every time I call this BBS I always connect properly at
  5722. 14400 with no problems. Thanks SUPRA. I do have problems though that I need to
  5723. bring to your attention. I use PROCOMM PLUS 2.01 and other modem programs also.
  5724. The HANGUP command does not always hang up the modem. I may have to issue  the
  5725. HANGUP command 3,4,5 times before I lose carrier. The CARRIER DETECT indicator
  5726. does not always report this data to my computer. thus I will show CD on the
  5727. modem but the computer thinks it is still not connected to carrier. And lastly
  5728. the modem will not search out 2400 baud carriers. I must set ATN0 while the
  5729. computer is offline and at 2400 before I can get an  incoming 2400 call. WHY
  5730. DON'T YOU POST THE NEW 1.200C ROM UPDATE FOR DOWNLOAD!
  5731.  
  5732.  
  5733. Msg#:  943 *MODEM*
  5734. 06-18-92 13:27:39
  5735. From: LARRY BLACK
  5736.   To: SYSOP
  5737. Subj: HOT MODEM
  5738. I tried to call the Tech Support # about this, but the number was either busy
  5739. or was not answered after about 15 rings.  Anyway, the modem that I got seems
  5740. to be running excessively hot, with the transformer being burning hot to the
  5741. touch, and the modem itself only slightly cooler.  Since the modem is intended
  5742. to be used in a BBS, that does not sound good. Can be reached voice at
  5743. 817-634-8006 from about 11:00 to 2 or 3, and at 793-3581 other times.  BBS
  5744. numbers are 793-3558 and 554-5331.
  5745.  
  5746. ROM version is 1.200C and the modem serial # is 14E-013522.  Would appreciate a
  5747. quick reply, as the modem otherwise seems to work quite well, and I would like
  5748. to get it into service.
  5749.  
  5750. I do have one question about the modem setup:  How can v.42bis be enabled while
  5751. disabling MNP5?  The reference guide implies that this can be done, but it does
  5752. not explain exactly how to do it.
  5753.  
  5754.  
  5755. Msg#:  955 *MODEM*
  5756. 06-19-92 00:38:13
  5757. From: STEVE PEPIN
  5758.   To: NATHAN (TECH SUPPORT)
  5759. Subj: NEW PROBLEM
  5760. I am having a problem that maybe you can help with.  I just purchased a
  5761.  Supra V.32bis modem for use on a RBBS system. I am running version 17.3b
  5762.  of RBBS-PC, and I suspect a problem in the init. strings.  The problem
  5763.  is this:  I am currently in the final test phase of getting this board up.
  5764.  I have myself and two other users who are helping me debug the system.  I
  5765.  have been getting complaints from both of them regarding grabage characters
  5766.  in the menus, etc.  I have not been able to confirm this by dialing into
  5767.  the system from my secondary computer.  I see everything fine.  They both
  5768.  get some garbage and are unable to D/L a good size file.  They are both
  5769.  using different modems and software and one has even called from work AND
  5770.  home.  I suspect a bad init string.  This is what I have:
  5771.         Modem initially open at 19200 and locked at this DTE speed.
  5772.         Reset:          ATZ
  5773.         Initialize:     ATE0M0V1W2X1S0=254S2=255S10=20
  5774.         Count # rings:  ATS1?
  5775.         Answer Phone:   ATQ0X1V1A
  5776.         Off Hook:       ATH1M0
  5777.         Clear Firmware: AT&F2
  5778.         Init. Firmware: AT&C1&D3B1E0V1M0S0=0
  5779.         Write Firmware: AT&W0
  5780.  Any suggestions would be most welcome.                   Steve Pepin...
  5781.  
  5782.  
  5783.  
  5784.  
  5785. Msg#:  960 *MODEM*
  5786. 06-19-92 05:56:16
  5787. From: SCOTT PIERCY
  5788.   To: SYSOP
  5789. Subj: SUPRAFAX & THE "*H" COMMAND
  5790. Just wondering why I cannot use the "*H" command that is outlined in the
  5791. manual.  It returns an "ERROR" message. Also, just exactly what new
  5792. capabilitiedoes the new ROM that's shipping in July give to the modem.  Thanks!
  5793. Scott Piercy Computer Port Inc.
  5794.  
  5795.  
  5796.  
  5797. Msg#:  974 *MODEM*
  5798. 06-19-92 09:53:02
  5799. From: LEE PARKS
  5800.   To: SYSOP
  5801. Subj: FAX TO DEX2400
  5802. I cannot get tmt supra v.32 fax modem to connect to a DEX 2400.  THe modems
  5803. just keep exchanging tones.......
  5804.  
  5805.  
  5806.  
  5807.  
  5808.  
  5809. Msg#:  979 *MODEM*
  5810. 06-19-92 16:17:19
  5811. From: LINDSEY MCMILLEN
  5812.   To: SYSOP
  5813. Subj: SUPRAFAXMODEM
  5814. I ordered two of your V.32bis modems from a local dealer here in Riverside in
  5815. mid May of this year.  He was able to provide me with one at that time, and
  5816. back ordered the other one.  Today I received the second unit and it appears
  5817. that the versions of ROM between the two are different.  The second unit was
  5818. shipped with a small pamphlet entitled "Important SupraFaxModem V.32bis
  5819. Information".  Among other things it tells of some new commands (%G and S110)
  5820. which will not work with my first unit.
  5821.  
  5822. I called your company voice a couple of days ago with regard to problems that
  5823. I've had with the first unit, and was put on a list for a new version of ROM
  5824. that was supposed to be shipped sometime "around the middle of July".  
  5825.  
  5826. As I was unable to make the two Supra Modems connect at 14.400 I have returned
  5827. the second unit, and with the refund purchased the Zoom Telephonics V.32bis
  5828. modem (which does connect with the my Supra).
  5829.  
  5830. I have tried to contact your company again by telephone without any success
  5831. other than receiving a busy signal.  Would you kindly have a representative of
  5832. your company call me COLLECT at 714-683-1219?  I would very much like to obtain
  5833. a more recent version of ROM before "Mid July".  My present version, as
  5834. displayed in response to the ATI3 command is Version 1.000.  I hope that
  5835. something can be done to change my opinion of the Supra as it seems like a nice
  5836. device, but with some problems.  In the meantime I am unable to recommend your
  5837. product over the Zoom to my clients.
  5838.  
  5839. I hope to hear from someone from your company soon.
  5840.  
  5841.  
  5842. Msg#: 1001 *MODEM*
  5843. 06-20-92 05:42:33
  5844. From: PATTI IRWIN
  5845.   To: LINDSEY MCMILLEN
  5846. Subj: REPLY TO MSG# 979 (SUPRAFAXMODEM)
  5847.    Hmmm...  I would of kept the new rom version and sent back the old rom
  5848. version...
  5849.  
  5850.  
  5851. Msg#:  981 *MODEM*
  5852. 06-19-92 16:50:25
  5853. From: JOHN WOZNACK
  5854.   To: SYSOP
  5855. Subj: SUPRAFAXMODEM TIMING.
  5856. Hi. I've been using your Supra Fax Modem, capable of 14.4, and have experienced
  5857. a problem. Sometimes when I here the modem connect at 14.4, the speaker goes
  5858. off, the panel shows 14.4 and CD, but the DCD line doesn't come up. If I force
  5859. the line up (at&c0), my software thinks the modem is on line, but the modem
  5860. doesn't seem to be in the "on-line" mode. (I think it is still negotiating the
  5861. speed or something.) After a few seconds, the remote modem hangs up. Is there
  5862. something I'm doing wrong? Perhaps I need to enable something? I've got the
  5863. modem set up for the most reliable connection. Any hints?
  5864. -JWW
  5865.  
  5866.  
  5867. Msg#:  983 *MODEM*
  5868. 06-19-92 18:41:36
  5869. From: TODD LAWYER
  5870.   To: SYSOP
  5871. Subj: SETTINGS
  5872. I need to dial a fax machine that takes many rings for the machine to answer.
  5873. How do I set the options in my fax software to ring for an extended period of
  5874. time??? Thanks! Todd
  5875.  
  5876.  
  5877. Msg#:  988 *MODEM*
  5878. 06-19-92 23:31:29
  5879. From: KERIEN FITZPATRICK
  5880.   To: ALL
  5881. Subj: FAX PROBLEMS WITH SUPRAFAXMODEM
  5882. I am having a slight problem implementing the UNIX Fax software that I have
  5883. using the SupraFAXmodem.  The software was written for the Everex EverFax
  5884. 24/96D which conforms to some version of Class2.  I am able to send a fax using
  5885. this software & the Supra, but the vertical scale is off.  What comes out is a 
  5886. page that is two pages long. Data format is set to 1-d huffman vertical
  5887. resolution is 196 lpi, width is 1728 pixels in 215mm, page length is unlimited,
  5888. error correction & bft are disabled.
  5889.  It seems as if possibly the vertical resolution is not getting set correctly.
  5890. Any insights from those a little more knowledgable about FAXes & their
  5891. software???
  5892.    Thanks,
  5893.       Fitz
  5894.  
  5895.  
  5896. Msg#: 1004 *MODEM*
  5897. 06-20-92 11:21:45
  5898. From: JOHN GOETHE
  5899.   To: SYSOP
  5900. Subj: SHIPPING ERROR
  5901. Hi,
  5902.         I received a box from you yesterday, 6/19/92, that contained ONE
  5903. SupraFAXModem.  I ordered TWO!  The packing slip said that TWO were ordered,
  5904. and that TWO were shipped!  But...there is only ONE in the box?!
  5905.         Also, I tried to set it up on TBBS, using the eSoft MODEM.DEF routine.
  5906. After about an hour of incoming calls that the modem accepted as incoming, but
  5907. TBBS not recognizing, I took the modem offline and replace it with the original
  5908. old modem.
  5909.         Why will TBBS not accept a call through your modem?  Has something
  5910. changed in the modem definition that eSoft is providing?  What are YOU using,
  5911. with TBBS, that allows callers to connect with your board?  Can you please pass
  5912. on the details to getting it to work with TBBS?
  5913.         My name is John Goethe, and I'm available for voice calls after 6pm
  5914. during the week at 816/887-3178, and on weekends.  During the week day, between
  5915. 8am-4pm, I can be reached at the office at 913/362-4345.  Times are Central
  5916. Daylight Time.  My BBS v.32 line (currently an HST Dual Standard that DOES
  5917. accept calls!) is 816/887-3480.
  5918.         Please have someone contact me to answer why I only received one modem
  5919. AND how to get the modem to work with TBBS.
  5920.                                 Thank you,
  5921.                                 John Goethe
  5922.  
  5923.  
  5924. Msg#: 1009 *MODEM*
  5925. 06-20-92 14:56:00
  5926. From: THOMAS KELLY
  5927.   To: NATHAN
  5928. Subj: V32.BIS MODEMS
  5929. Have not received replacement modem as of yet for the IBM package.  Hope it ill
  5930. be here soon!  Have gotten the Amiga package.  It works great as a Fax, however
  5931. the modem is having many of the same problems with busy detection (lack of),
  5932. erroneus messages after connection, and an aggrevating problem with the
  5933. software (which is pretty buggy as far as I can tell).  The software constantly
  5934. assumes there is no answer and starts the modem through a redial session while
  5935. the modem is showing it is connected.  After the software starts to monitor for
  5936. connect, however it still acts as if it hasn't and redials again , and again ,
  5937. etc.
  5938.         Will likely call you midweek if no message from you.
  5939.                                         Tom Kelly
  5940.                                       (504) 682-3809(w)
  5941.                                        (504) 682-9118 (h) exit
  5942.  
  5943.  
  5944. Msg#: 1026 *MODEM*
  5945. 06-20-92 22:13:03
  5946. From: JIMMY DUARTE
  5947.   To: ALL WWIV SYSOPS
  5948. Subj: 14.4 INIT FOR WWIV 4.21
  5949. We just added a Supra Faxmodem to our BBS and are getting great thruput for
  5950. file transfers. Any sysop needing assistace may call The Beacon BBS 24 hours a
  5951. day for help at (704)344-1572.
  5952.  
  5953.  
  5954. Msg#: 1037 *MODEM*
  5955. 06-21-92 12:21:02
  5956. From: STEPHEN J. O'CONNOR
  5957.   To: SYSOP
  5958. Subj: ROM UPGRADE
  5959. I would like to be put on the upgrade list for the ROMS for my SupraFaxmodem.
  5960. My info is:                                                 Stephen J. O'Connor
  5961. 1518 Clayton Marsh Drive                                                   Lake
  5962. In The Hills,Il. 60102-1034                                           (708)
  5963. 658-5923 Phone or Fax.
  5964.  
  5965.  
  5966. Msg#: 1043 *MODEM*
  5967. 06-21-92 18:26:56
  5968. From: PAUL THEODOROPOULOS
  5969.   To: MARK WHITE (Rcvd)
  5970. Subj: ROMS
  5971. well, although previous statements here have indicated that all registered
  5972. users will get the new ROMS, i have also seen requests by tech support for
  5973. addresses to send ROMS to. therefore, i submt my address: Paul Theodoropoulos 
  5974. 50 Sonoma St #4 San Rafael, CA 94901
  5975.  
  5976.  
  5977. Msg#: 1044 *MODEM*
  5978. 06-21-92 19:52:27
  5979. From: BILL INABNETT
  5980.   To: CUSTOMER SUPPORT
  5981. Subj: EPROMS FOR MY FAX MODEM
  5982. Yes, I have one of the first 14400 v32bis faxModems. I have sent the warranty
  5983. card in over 2-3 months ago. Someone said they would be sending me some updated
  5984. eproms (and any hardware modifications) I need to make. They said the eproms
  5985. would be sent out on about 1 June 1992. Anyway, I have not hear heard a word
  5986. about any of this nor have I receive anything! Also, I think this guy's name
  5987. was Mark, but am not sure. Hesaid also they were going to fix the
  5988. slowdown/speedup problem so th at the Supra modem can slowdown and speedup with
  5989. HST HST modems.  Also, it seems I have to call everyone almost twice before
  5990. making good conection. I sold my USRobotics Dual Std in order to get this thing
  5991. and also the 14.4 fax dosent seem to work.
  5992.     Please send complete updates (roms/eproms/hardware
  5993.      modifications) so I can bring this modem up to s
  5994.     speed.  My card is on file:
  5995.                           Bill Inabnett
  5996.                           1410 Bob White Drive
  5997.                           Garland, Tx 75040
  5998.        
  5999.                          Telephone 214-840-1822 If necessary, I can fed-ex my
  6000. modem to you for update also. Someone please call and let me know what to do.
  6001. If I am not here, simply leave a message as to what you/me should do.
  6002.        Thanks,
  6003.          Bill
  6004.  
  6005.  
  6006. Msg#: 1208 *MODEM*
  6007. 06-25-92 01:46:19
  6008. From: MARK WHITE
  6009.   To: BILL INABNETT
  6010. Subj: REPLY TO MSG# 1044 (EPROMS FOR MY FAX MODEM)
  6011. Your name is on the list that I sent to shipping 6/16.  I know that they are
  6012. finishing up shipping out the ROM kits from that list.  Hang tight for a few
  6013. more days and you should see it appear on your doorstep.
  6014.  
  6015. Mark - Supra Tech Support
  6016.  
  6017.  
  6018. Msg#: 1212 *MODEM*
  6019. 06-25-92 01:56:16
  6020. From: GENE STEINBERG
  6021.   To: MARK WHITE (Rcvd)
  6022. Subj: REPLY TO MSG# 1208 (EPROMS FOR MY FAX MODEM)
  6023. With regard to the ROM updates: I got a ROM kit myself (there is supposed to be
  6024. a later revision in July, right?), but I understand it incorporates the same
  6025. 1.20-C ROM as my warranty replacement unit. Unfortunately, I did not have a
  6026. chance to check this out. When I tried to open the modem, I found that one of
  6027. the screws was tightened so much, that I managed to strip it and still not
  6028. loosen it. I trust this is not the norm, as users who want to replace ROMs are
  6029. gonna have a heck of a time. If the present ROM kits contain what I have
  6030. already, I'll await the July revision (could you clarify this?). Perhaps you
  6031. ought to send a replacement unit when the new ROM is ready. Keep me posted. 
  6032. Peace, Gene Steinberg
  6033.  
  6034.  
  6035. Msg#: 1214 *MODEM*
  6036. 06-25-92 02:10:48
  6037. From: MARK WHITE
  6038.   To: GENE STEINBERG (Rcvd)
  6039. Subj: REPLY TO MSG# 1212 (EPROMS FOR MY FAX MODEM)
  6040. The 1.200C rom has two major enhancements, Rockwell's code for faxing and the
  6041. Supra's inital fallback code, which was done a little over a month ago.  We
  6042. have spent a great deal of time refinning the fallback code, adding other
  6043. enhancements, and fixing several of Rockwell's bugs.  So it many ways, the
  6044. mid-july rom will be as big as step up as the 1.200C was from 1.000E.
  6045.  
  6046. Mark - Supra Tech Support
  6047.  
  6048.  
  6049. Msg#: 1253 *MODEM*
  6050. 06-25-92 15:40:07
  6051. From: GENE STEINBERG
  6052.   To: MARK WHITE (Rcvd)
  6053. Subj: REPLY TO MSG# 1214 (EPROMS FOR MY FAX MODEM)
  6054. Sounds interesting. But unless you can figure out a way for me to get that
  6055. "stripped" screw open, I'm gonna have to exchange the modem for the ROM update
  6056. (as an AOL Forum Assistant I can't be without a modem for even a day!). Any
  6057. thoughts? (And maybe a replacement screw!) Peace, Gene
  6058.  
  6059.  
  6060. Msg#: 1263 *MODEM*
  6061. 06-25-92 20:45:47
  6062. From: MARK WHITE
  6063.   To: GENE STEINBERG (Rcvd)
  6064. Subj: REPLY TO MSG# 1253 (EPROMS FOR MY FAX MODEM)
  6065. Have you taken the back plate off and tried using a needle nosed plier to hold
  6066. the stud will un-screwing the screw?  If this does not work, then yes, we can
  6067. do our Supra exchange program.
  6068.  
  6069. Mark - Surpa Tech Support
  6070.  
  6071.  
  6072. Msg#: 1280 *MODEM*
  6073. 06-26-92 07:02:56
  6074. From: GENE STEINBERG
  6075.   To: MARK WHITE (Rcvd)
  6076. Subj: REPLY TO MSG# 1263 (EPROMS FOR MY FAX MODEM)
  6077. I'll try that, Mark, when I get the new ROMS. Can you at least send me a set of
  6078. replacement screws: Gene Steinberg, 422 Westgate Drive, Edison, NJ 08820-1172.
  6079. I'll give it a try when the ROMS arrive, and let you know if an exchange is
  6080. needed. Obviously, the modem otherwise works well (even the speaker, thank
  6081. heavens) and I shouldn't wish to change it if not necessary. Peace, Gene
  6082.  
  6083.  
  6084. Msg#: 1312 *MODEM*
  6085. 06-26-92 23:15:08
  6086. From: MARK WHITE
  6087.   To: GENE STEINBERG (Rcvd)
  6088. Subj: REPLY TO MSG# 1280 (EPROMS FOR MY FAX MODEM)
  6089. I don't believe the screws are actually stripped.  If it is what I have seen
  6090. before, the stud (for lack of a better term) that the screw screws into has
  6091. started to unscrew it self. In other words, one end has a screw hole which
  6092. accepts the screws and the other end has threads which screw into the bottom of
  6093. the RS232 plug.  This clamps together the RS232 plug, the PC board and the
  6094. case.  All you should need to do is pop the back plastic plate off, use a
  6095. needle nose plier to old the stud and then unscrew the screw.  Pull the pc
  6096. board out, and tighten up the stud into the pc board/rs232 plug.  Put it back
  6097. in the case and putthe screw back in.
  6098.  
  6099. Mark - Supra Tech Support
  6100.  
  6101.  
  6102. Msg#: 1322 *MODEM*
  6103. 06-27-92 04:38:24
  6104. From: GENE STEINBERG
  6105.   To: MARK WHITE
  6106. Subj: REPLY TO MSG# 1312 (EPROMS FOR MY FAX MODEM)
  6107. Maybe so. But the head of the screw is now stripped because of all the effort I
  6108. expended trying to get it to move (it was in solid!), an unsuccessful effort I
  6109. might add. If I can free it the way you suggest, I'd still want a new set of
  6110. screws. Peace, Gene
  6111.  
  6112.  
  6113. Msg#: 1045 *MODEM*
  6114. 06-21-92 20:38:30
  6115. From: ROBERT UPTON
  6116.   To: NATHAN
  6117. Subj: MODEM CLICKING
  6118. Hi .... What would cause clicking when trying to connect. Only way to stop it
  6119. is to repeatidly try a number, escape out,  and then try again. Usually takes
  6120. about 8-9 time before it dials. If I leave modem on and do not turn it off, it
  6121. works fine. Thanks
  6122.  
  6123.  
  6124. Msg#: 1046 *MODEM*
  6125. 06-21-92 21:38:32
  6126. From: DARREN COLE
  6127.   To: MARK
  6128. Subj: ROM UPGRADE
  6129. ........,,[]
  6130.  
  6131. Well, I have the supra Fax Modem 14.4 and want to get my rom Upgrade too, My
  6132. address is Darren Cole 932 Parker St. Charlotte Nc 28216 Thanks for the help.
  6133. Also, I have a problem with my modem, I cannot issue any of the % commands in
  6134. the manual, that and any of the - commands, I tryed to use the -b1 command to
  6135. log onto a board with 1200 But it will not work. Any suggestions???
  6136.  
  6137. Thanks....
  6138.  
  6139.  
  6140.  
  6141. Msg#: 1127 *MODEM*
  6142. 06-22-92 15:54:56
  6143. From: GERGELY J. TAPOLYAI
  6144.   To: SYSOP
  6145. Subj: AT&T
  6146. Thank you for your advice on the &T, test mode. Infortunatelly the modem still
  6147. replies with an error.  The following is the result: atz OK atns37=9 OK at&q0 
  6148. OK at&t8 ERROR Lower case is my input and uppercase is the modems response. I
  6149. am still wondering if the &T is left out some way or an other from the modems
  6150. command set. Please advise further. Thank you, Gergely Tapolyai
  6151.  
  6152.  
  6153. Msg#: 1306 *MODEM*
  6154. 06-26-92 17:44:01
  6155. From: GERGELY J. TAPOLYAI
  6156.   To: MARK WHITE (Rcvd)
  6157. Subj: REPLY TO MSG# 1209 (AT&T)
  6158. Thank you for your reply.   I will try that.  Although the program attempts to
  6159. run it in 3 different speeds depending on the reported top speed.   Also, since
  6160. my modem ROM version is 1.00, how do I get an update for it?  I have sent in my
  6161. registration card as soon as I recieved the modem; about 2 month ago.   Again,
  6162. thanks
  6163. . Gergely
  6164.  
  6165.  
  6166. Msg#: 1315 *MODEM*
  6167. 06-26-92 23:20:20
  6168. From: MARK WHITE
  6169.   To: GERGELY J. TAPOLYAI
  6170. Subj: REPLY TO MSG# 1306 (AT&T)
  6171. We will be sending out a new rom mid-July to all registered owners.
  6172.  
  6173. Mark - Supra Tech Support
  6174.  
  6175.  
  6176. Msg#: 1134 *MODEM*
  6177. 06-22-92 19:57:02
  6178. From: ALAN BROWN
  6179.   To: DAVID FUNG
  6180. Subj: PROBLEM V.32BIS
  6181. I am also having this problem.  I am using the v.32bis on a IIci.  It turnns
  6182. itself off continually to the point that it is unusable (I am currently using a
  6183. borrowed modem).  Is this a bug in the modem or do I have a lemon? I just
  6184. purchased it.  I also tried it out on a friend's computer and had the same
  6185. problem.  We are both using System 7.01 and tuner. Let me know what to do. 
  6186. Also, I can barely read this bulletin board.  Most of the info is garbled.  I
  6187. am using a Supro Fax Modem v.32 (borrowed while I am waiting from you to let me
  6188. know what to do with mine.
  6189.  
  6190.  
  6191. Msg#: 1210 *MODEM*
  6192. 06-25-92 01:51:40
  6193. From: MARK WHITE
  6194.   To: DAVID FUNG
  6195. Subj: REPLY TO MSG# 1134 (PROBLEM V.32BIS)
  6196. Your problem is that you have incorrectly configured the modem.  On the Mac,
  6197. the handshake out and DTR share the same line.  So when the Mac exerts flow
  6198. control and you have the modem configured for &D1/2/3, the modem will hangup.
  6199. The solution is to use the &F1 or explicetly state &D to tell the modem to
  6200. ignore the DTR line.
  6201.  
  6202. Mark - Supra Tech Support
  6203.  
  6204.  
  6205. Msg#: 1211 *MODEM*
  6206. 06-25-92 01:54:26
  6207. From: MARK WHITE
  6208.   To: ALAN BROWN
  6209. Subj: REPLY TO MSG# 1134 (PROBLEM V.32BIS)
  6210. It sounds like you have incorrectly configured the modem.  On the Mac, the
  6211. handshake out and DTR are connected to the same line.  When the Mac exerts flow
  6212. control to tell the modem to stop sending, DTR is also toggled.  Since you have
  6213. not told the modem to ignore the DTR line, &D, the modem respects the DTR and
  6214. either hangsup or does a reset which will also hang you up.  You need to use
  6215. either the &F1 command or explicatly tell the modem to ignore DTR with the &D
  6216. command.
  6217.  
  6218. Mark - Supra Tech SUpport
  6219.  
  6220.  
  6221. Msg#: 1136 *MODEM*
  6222. 06-22-92 21:38:55
  6223. From: ROBERT UPTON
  6224.   To: NATHAN
  6225. Subj: CLICKING
  6226. Answer message 1045 please ... my phone bill is skyrocketing.
  6227.  
  6228.  
  6229. Msg#: 1137 *MODEM*
  6230. 06-22-92 21:54:39
  6231. From: ANTHONY DOBRE
  6232.   To: SYSOP
  6233. Subj: NEW ROMS
  6234. Can you please post the latest revision ROMS for download purposes. I and many
  6235. others have the equipment to reburn our EPROMS ourselves. Please answer this
  6236. question, this is the second time I am asking it here! Please post version
  6237. 1.200c for download!
  6238.  
  6239.  
  6240. Msg#: 1142 *MODEM*
  6241. 06-23-92 00:33:40
  6242. From: ELVIN EMERY
  6243.   To: SYSOP
  6244. Subj: 1.200C
  6245.  I got the new 1.200C ROMS for my SupraFaxModem v32BIS and they work great!!  I
  6246. now can just tell the modem to dial this BBS the the Fallback works fine.   I
  6247. was taken my surprise when I went to the mailbox today and found the the roms.
  6248. I called and asked if I would be getting another set of roms in July and was
  6249. told yes and that the next set would have fallforward and adjust some things in
  6250. order to work with more modems (like the older HST DS ones).  
  6251.  
  6252.   The one question that I have is when will I get my GPFAX software!!!
  6253.  
  6254.   I orderd it in late April and was told they are waiting for the manuals of
  6255. all things!!  Now its late June and no GP Fax!!
  6256.  
  6257.  
  6258. Msg#: 1143 *MODEM*
  6259. 06-23-92 00:52:26
  6260. From: MATTHEW ZUKOWSKI
  6261.   To: ALL
  6262. Subj: BUFFERS
  6263. I have a question.
  6264.  I am curently using the Supra 14.4 modem with my bbs (Citadel system) and am
  6265. wondering is there anyway to turn the modem buffers off (or atleast make the
  6266. modem buffer smaller).
  6267.  
  6268.  Also is there a way that you can alter the way the modem deals with a break
  6269. signal.  As in is there anyway of making the modem respond to a break as
  6270. follows:
  6271.  Clear Buffer
  6272.  Tranmit "S" to the computer
  6273.  
  6274.  Also.  What is this Rom Upgrade that everyone is talking about.
  6275.  
  6276.  
  6277. Msg#: 1157 *MODEM*
  6278. 06-23-92 13:10:31
  6279. From: ALFREDO ROJAS
  6280.   To: SYSOP
  6281. Subj: ROM UPGRADE
  6282. I have bought two Supra modems Serial #s - 14E006376 and 14E006398 Alfredo
  6283. Rojas 4301 Rickenbacker Causeway Miami, FL 33149 I will be sending registration
  6284. cards today.... Thanks... P.S. - will be buying two more Supra Modems next
  6285. week!
  6286.  
  6287.  
  6288. Msg#: 1165 *MODEM*
  6289. 06-23-92 21:20:18
  6290. From: BOB SHATTLER
  6291.   To: SUPRA
  6292. Subj: ROMS
  6293. I was pleasantly surprised to have received the ROM updates for my Supra Fax
  6294. Modem.  The installation was easy & quick.  I was able for the first time to
  6295. connect here at 14400.  Thanks for the support!
  6296.  
  6297.  
  6298. Msg#: 1168 *MODEM*
  6299. 06-24-92 00:14:15
  6300. From: KEN WARM
  6301.   To: SUPRA
  6302. Subj: FAX
  6303. I have tried to Fax with both GPFax (Amiga) and the Windows Fax software you
  6304. are packaging. When I try to use GPFax the modem starts beeping in the middle
  6305. of the tone dial-string and thus never connects to the remote Fax. When I use
  6306. the Windows software the dialing is successful, but after about 2 seconds of
  6307. connection time, the modem hangs up with the message "+FHNG:2". Hopefully both
  6308. problems have an easy solution. BTW, I am using both software packages on a
  6309. third SupraFax v.32bis bought very early in your marketing. Please also let me
  6310. know if you have my modem registered, or do I have to go hunting for the card.
  6311. I believe I did send it right in because I am interested in Voice Mail. Thanks
  6312. - KW
  6313.  
  6314.  
  6315. Msg#: 1180 *MODEM*
  6316. 06-24-92 11:54:37
  6317. From: BOB LAPAGE
  6318.   To: SYSOP
  6319. Subj: NEW ROMS
  6320. I have been having problems lately with my Supra 14.4 modem . I have always had
  6321. problems on 14.4 connects long distance no matter where or who's phone line I
  6322. use. In addition lately my modem is acting strange. I set S37=9 and N0 to force
  6323. no higher than 9600. I connect and it shows 9600 but then goes and shows 14.4
  6324. and disconnects. How can this be when I locked it lower and I know the Supra
  6325. had a problem jumping up to a higher speed because of a bug. I also have never
  6326. been able to get then Fax working correctly. This was a major reason for
  6327. getting the Supra. I would like to make sure that I am on the list for the
  6328. upgrade to new roms and hope they will help. Ser. # 14E 002620  V1.000-E
  6329. TR14-Jxxx-001 003                   Here is my address:
  6330.                     Robert LaPage
  6331.                     RR #3 Box 1003
  6332.                     Wells, Me.  04090
  6333.                      (207) 646-6995 I have sent in my registration about 3-4
  6334. weeks ago if you don't have it please let me know.
  6335.                                               Thanks,  Bob LaPage
  6336.  
  6337.  
  6338. Msg#: 1213 *MODEM*
  6339. 06-25-92 02:04:31
  6340. From: MARK WHITE
  6341.   To: BOB LAPAGE (Rcvd)
  6342. Subj: REPLY TO MSG# 1180 (NEW ROMS)
  6343. Your problem with configuring the modem to connect at 9600, making the
  6344. connection, and then jumping upto 14.4K is NOT a bug or problem with the Supra,
  6345. but rather a BUG in the modem that you are calling to.  We had another user
  6346. report the same thing.  Our engineer was working on the fall back code at the
  6347. time and when I told him about this, he checked his code and found that he had
  6348. the same problem.  After fixing it, one of his checks to see that the code was
  6349. working correctly was to set an older rom for connecting at only 9600.
  6350. Everything worked correctly.
  6351.  
  6352. Mark - Supra Tech Support
  6353.  
  6354.  
  6355.  
  6356. Msg#: 1182 *MODEM*
  6357. 06-24-92 12:12:48
  6358. From: URBAN LARSSON
  6359.   To: DARRELL SANDERSON
  6360. Subj: MAILREADER
  6361. Hi Darrell, I saw your message to the Sysop regarding mailreading programs. Try
  6362. reading two messages I left here, named "Problems connecting?" and "Problems
  6363. connecting-Part two", if they still exist in the modem area.
  6364.  
  6365. If you can't find them, they mentioned that you set the capture to ON in your
  6366. software (save all incooming text to file), and issue the command "Read
  6367. messages board by board" followed by "Reading all mail" (or perhaps "All new"
  6368. if you already read the old messages). Also select "Always follow" to make it
  6369. easier to read the replays. No pause between messages, and logoff when the
  6370. scrolling stops. 
  6371.  
  6372. You now have the messages you wanted in a capture file that you easy can  edit
  6373. and read with your own wordprocessor. It takes only a minute or two  to
  6374. download all messages this way if you use at least 9600 bps and V42bis. (V42bis
  6375. or similar is important when transfering textfile, it compresses  the text up
  6376. to four times to reduce transfer time.)
  6377.  
  6378. Also make any comments and replays with the wordprocessor and upload them with
  6379. ascii protocol into the fullscreen editor after you select name and subject in
  6380. the "Create message" command.
  6381.  
  6382. With this system you cut down on the online time to only one or two minutes. 
  6383. And as bonus, makes the BBS free to other users almost instantly.
  6384.  
  6385.  
  6386.  
  6387.   Happy modeming with new reduced phone cost,   Regards Urban Larsson, Sweden
  6388.  
  6389.  
  6390.  
  6391. Msg#: 1184 *MODEM*
  6392. 06-24-92 15:33:24
  6393. From: RON SCHWARZ
  6394.   To: SYSOP
  6395. Subj: V.32BIS PROBLEM
  6396. I just received my Supra v.32bis modem back from warranty repair (it was a new
  6397. modem).  I am still having one problem, which is that I must use X2 (rather
  6398. than X4) because when I use X4 it always thinks the line is busy and
  6399. disconnects! I have seen this in other Supras, and I believe that it is a
  6400. firmware problem.  I would like you to confirm that this problem will be
  6401. resolved with your ROM upgrade, and that you have my name/card on file (which I
  6402. presume to be the case, since you repaired my modem under warranty, but why
  6403. take chances!)
  6404.  
  6405. Thanks,
  6406.  
  6407. Ron Schwarz Launch Systems Software (517) 773-5366 (voice) (517) 773-2400 (fax)
  6408.  
  6409.  
  6410. Msg#: 1186 *MODEM*
  6411. 06-24-92 16:12:16
  6412. From: ANTHONY DOBRE
  6413.   To: SYSOP
  6414. Subj: POOR TECHNICAL SUPPORT?
  6415. This is my third request for the new ROM upgrade to be posted on the Download
  6416. Section. Why have you not responded to my previous two requests concerning this
  6417. question. Maybe all those people who have been complaining in this message base
  6418. have something to gripe about after all!  POOR TECHNICAL SUPPORT!!!!!!!
  6419.  
  6420.  
  6421. Msg#: 1224 *MODEM*
  6422. 06-25-92 08:56:47
  6423. From: JAMES MARPLE
  6424.   To: ANTHONY DOBRE (Rcvd)
  6425. Subj: REPLY TO MSG# 1186 (POOR TECHNICAL SUPPORT?)
  6426. You might not want to receive a rom that way, as it will bend the pins when it
  6427. goes thru the phone line.. Actually, you could do what you are talking about
  6428. (Download the code), but you can't load it into a ROM. You could load it into
  6429. an EPROM..
  6430.  
  6431.  
  6432. Msg#: 1201 *MODEM*
  6433. 06-24-92 23:46:03
  6434. From: JASON PIA
  6435.   To: RON SCHWARZ
  6436. Subj: BUSY PROBLEMS
  6437. I too am having the same problem. The modem reports BUSY when in fact the line
  6438. is ringing and waiting for the other modem to answer. I have not tried your
  6439. solution (although it should obviously work) but it also seems to work properly
  6440. if you use ATM to turn the speaker off. I have not tried this a great deal but
  6441. it has worked on the last 6-7 times I tried it. I would be a little patient
  6442. about getting a response, it usually seems to take about a week for Nathan to
  6443. get round to answering peoples queries. TTFN, Jason
  6444.  
  6445.  
  6446. Msg#: 1219 *MODEM*
  6447. 06-25-92 06:38:14
  6448. From: DAVE KALWISHKY
  6449.   To: SYSOP
  6450. Subj: AUTO ANSWER
  6451. I am having a problem with my new V.32 Fax modem, when I issue an ATS0=1 from
  6452. my term program I expect my modem to answer the phone when it rings, it does
  6453. not.  The status display says AA and when the incoming ring is detected it says
  6454. RI but it will NEVER answer the phone.  I even tried unplugging the phone from
  6455. the modem and that did not help, my ROM revesion is 1.2C.....  Any suggestions?
  6456.            Dave Kalwishky
  6457.  
  6458.  
  6459. Msg#: 1220 *MODEM*
  6460. 06-25-92 06:42:09
  6461. From: HABIB BITAR
  6462.   To: SYSOP
  6463. Subj: DEALER PRICING AND ORDERING TWO SUPRA MOD
  6464. called your sales dept.and asked to call you for qualification to buy to ext
  6465. suprafax v.32 at dealer prices voice tel (713) 995-9741 microtrend computers 
  6466. 10101 harwin suite 160 houston,tx 77036
  6467.  
  6468.  
  6469. Msg#: 1227 *MODEM*
  6470. 06-25-92 10:18:19
  6471. From: ANTHONY DOBRE
  6472.   To: JAMES MARPLE (Rcvd)
  6473. Subj: BENT PINS
  6474. I think your pins are slightly bent too!
  6475.  
  6476.  
  6477. Msg#: 1302 *MODEM*
  6478. 06-26-92 12:47:36
  6479. From: JAMES MARPLE
  6480.   To: ANTHONY DOBRE
  6481. Subj: REPLY TO MSG# 1227 (BENT PINS)
  6482. I would be the first to admit that my pins are bent, but they still work :-)
  6483.  
  6484.  
  6485. Msg#: 1228 *MODEM*
  6486. 06-25-92 10:21:31
  6487. From: ANTHONY DOBRE
  6488.   To: MARK WHITE (Rcvd)
  6489. Subj: NEW ROMS
  6490. This is my 4th request with still no answer. Please post the new ROM updates
  6491. for DownLoad on this BBS so that people with the equipment can update their own
  6492. modems. I have no FAX capability at all on my 14E series modem and I would like
  6493. to D/L the ROMS to do my own upgrade as fast as possible.
  6494.  
  6495.  
  6496. Msg#: 1262 *MODEM*
  6497. 06-25-92 20:43:36
  6498. From: MARK WHITE
  6499.   To: ANTHONY DOBRE
  6500. Subj: REPLY TO MSG# 1228 (NEW ROMS)
  6501. I am sorry, we will not be providing the code as a file.  It is incorrectly
  6502. rumoured that what we will be shipping mid-july is nothing more than v1.200C
  6503. code.  Nothing could be further from the truth.  The code that is the 1.200C
  6504. code was written over a month ago.  Since then, we have been busy working and
  6505. improving our fall back code.  We have implemented other enhancements to the
  6506. Rockwell code, and we have fixed numerous Rockwell bugs.  As far as we have
  6507. been able to determine, no of the other OEMs who are using the Rockwell chipset
  6508. will have the features that ours has.
  6509.  
  6510. Mark - Supra Tech Support
  6511.  
  6512.  
  6513. Msg#: 1232 *MODEM*
  6514. 06-25-92 12:51:01
  6515. From: BARRY MOORE
  6516.   To: SUPRA
  6517. Subj: MODEM SPEAKER
  6518.  Hi,   I was wondering if there is anything I can do since the speaker doesn't
  6519. seem to work very much anymore. Sometime it may come on and rattle a bit.  No
  6520. problem with connecting or dialing. If there is a way around sending the modem
  6521. back to you, I would rather take that route.
  6522.   Thanks in advance...
  6523.    Barry Moore
  6524.  P.S. The modem is about 2 to 3 weeks old and I have sent in the registration
  6525. card. (v32-bis faxmodem).
  6526.  
  6527.  
  6528. Msg#: 1255 *MODEM*
  6529. 06-25-92 17:43:07
  6530. From: DAVID POTTER
  6531.   To: SYSOP
  6532. Subj: CLASS 2 FAX VERTICAL RESOLUTION
  6533. We are developing fax software running on VAX/VMS to drive Class 2 fax modems
  6534. (our company is Data Processing Design, Inc.).  Thus far we have had quite a
  6535. bit of success with the SupraFAXModem V.32bis fax modem.  The new ROM's helped
  6536. (V1.2000C) a lot.
  6537.  
  6538. We are having one problem, however, with sending faxes using NORMAL vertical
  6539. resolution (98 lpi).  We issue the AT +FDT=0,0 command to indicate we want the
  6540. NORMAL vertical resolution, however the fax on the receiving fax machine comes
  6541. out in FINE vertical resolution (196 lpi).
  6542.  
  6543. We have also been testing with the Multi-Modem II from Multi-Tech and have had
  6544. no problems sending in 98 lpi (the Multi-Modem is another Class 2 fax modem
  6545. implentation at a much higher cost than the SupraFAXModem).
  6546.  
  6547. Please reply to my message as soon as possible, or even call me between 9am and
  6548. 6pm PDT at (714) 974-1515 (just ask for me).  We need to have this resolved
  6549. before we ship (hopefully end of July/middle of August).
  6550.  
  6551. I should note that before we upgraded the ROM's NORMAL vertical resolution
  6552. worked fine.
  6553.  
  6554. Thanks for your attention in this matter, David Potter
  6555.  
  6556.  
  6557. Msg#: 1256 *MODEM*
  6558. 06-25-92 17:47:21
  6559. From: DAVID POTTER
  6560.   To: SYSOP
  6561. Subj: SPEAKER VOLUME
  6562. We have had very few problems with the SupraFAXModem since we upgraded the
  6563. ROM's (other than the vertical resolution problem I described in an earlier
  6564. message).
  6565.  
  6566. One problem we have had, though, is probably a fairly trivial one.  It seems
  6567. that the volume of the speaker cannot really be controlled.  When using the
  6568. ATL0 or ATL1 commands, the volume seems to be no lower than the default, or
  6569. ATL2.  Of course, it would be ideal if there were a physical volume switch.
  6570. The only reason this is really a problem is that I work in a cubicle, and
  6571. whenever I test the fax software I am writing everyone around is disturbed.
  6572.  
  6573. Thanks, David
  6574.  
  6575.  
  6576. Msg#: 1257 *MODEM*
  6577. 06-25-92 18:07:12
  6578. From: KEITH CHUMLEY
  6579.   To: SYSOP
  6580. Subj: V.32BIS & LOUD BUZZ IN PHONE
  6581.   I'm still having a major problem with my v.32bis modem. If the serial cable
  6582. connecting the modem to the mac is plugged in, there is a horrible buzzing
  6583. noise on the phone line! This renders the phone unusable while the modem is
  6584. plugged in! If I disconnect the serial cable, all is well. The mac and modem
  6585. don't have to be on, just connected. The modem works fine, but the phone is a
  6586. higher priority. I just can't keep unplugging the modem
  6587.  whenever someone calls! Especially if I'm on the computer at the time - I
  6588. don't like disconnecting peripherals while the power is on (or reconnecting
  6589. when they hang up). Who can help me? Anyone have this problem before? Is it a
  6590. hardware problem inside the modem? Someone suggested I should ask tech support
  6591. for filter of some sort for the serial port.  HELP!!!!    Thanks for any
  6592. assistance! (I'd hate to have to return this modem!)    - Keith C.
  6593.  
  6594.  
  6595. Msg#: 1261 *MODEM*
  6596. 06-25-92 20:10:59
  6597. From: PAUL WARREN
  6598.   To: TECH SUPPORT
  6599. Subj: NEW CHIP SET
  6600. I have just recieved new chip set today for v32bis Supra Fax modem. I recieved
  6601. 2 modems through SYSOP program and have not been able to use them as of yet
  6602. because my 2400 baud users have trouble loging in. I have had to kkeep my US
  6603. Roboitics D/S on line because of that.  I think this chip set will fix that
  6604. problem,  the problem now is that I only recieved 1 set of chips I need another
  6605. set of chips for the other modem. could you please send them out?. Paul Warren
  6606. Sysop AlterNet BBS  508-827-5274 254 Ashby Road Ashburnham, MA 01430 Voice
  6607. (508) 827-4455 modem serial numbers ar 14E 000604    14E001438 Thanks for your
  6608. help
  6609.  
  6610.  
  6611. Msg#: 1265 *MODEM*
  6612. 06-25-92 21:08:12
  6613. From: STEVEN MEYER
  6614.   To: MARK WHITE (Rcvd)
  6615. Subj: V32.BIS PROBLEMS AT 9.6 AND 14.4
  6616. We just got two v32.bis modems (6/22) and we're having problems connecting at
  6617. 9.6 and 14.4.  We generally get a carrier detect OK but then the modems drop
  6618. off line without getting a protocol or falling back.  If I use N0 ans s37=6, we
  6619. connect up just fine at 2400.  We have 1.200C ROMS.  Any ideas?
  6620.     
  6621. Thanks, Steve Meyer
  6622.  
  6623.  
  6624. Msg#: 1268 *MODEM*
  6625. 06-25-92 21:44:55
  6626. From: MARK WHITE
  6627.   To: STEVEN MEYER (Rcvd)
  6628. Subj: REPLY TO MSG# 1265 (V32.BIS PROBLEMS AT 9.6 AND 14.4)
  6629. What happens if you use ATN0S37=9?  What type of computer and what is its
  6630. speed?  What speed do you have the terminal speed set to.
  6631.  
  6632. Mark - Supra Tech Support
  6633.  
  6634.  
  6635. Msg#: 1299 *MODEM*
  6636. 06-26-92 11:01:41
  6637. From: STEVEN
  6638.   To: MARK WHITE (Rcvd)
  6639. Subj: REPLY TO MSG# 1268 (V32.BIS PROBLEMS AT 9.6 AND 14.4)
  6640. atn0s37=9 gives me the same effect as atn1, but the carrier connects at 9600.
  6641. That is, I get several rounds of negotiation, the modem shows a 96, then drops
  6642. off line before any other status messages are shown, and before any status
  6643. replies are sent to the computer.  We're using 25MHz '040 NeXTs, with flow
  6644. control.  When we connect to an ATI V.32 modem that we have on another machine,
  6645. it picks up the 9600 immediately, sets up the EC and compression, and works
  6646. fine.  This is all with the serial line speed set to 38400.
  6647.  
  6648.  
  6649. Msg#: 1314 *MODEM*
  6650. 06-26-92 23:18:40
  6651. From: MARK WHITE
  6652.   To: STEVEN
  6653. Subj: REPLY TO MSG# 1299 (V32.BIS PROBLEMS AT 9.6 AND 14.4)
  6654. Have you tried setting the serial port speed lower?
  6655.  
  6656. Mark - Supra Tech Support
  6657.  
  6658.  
  6659. Msg#: 1275 *MODEM*
  6660. 06-25-92 23:27:01
  6661. From: VLADEK KOMOREK
  6662.   To: SYSOP
  6663. Subj: FAX
  6664. Did you receive my fax? I sent a fax to Technical Support about a problem with
  6665. FaxTalk Plus software + SupraFaxModem v.32bis and BBS. Vladek
  6666.  
  6667.  
  6668. Msg#: 1277 *MODEM*
  6669. 06-26-92 01:31:30
  6670. From: ROBERT BARNHARDT
  6671.   To: SYSOP
  6672. Subj: USR DS: FAILED CONNECTS.
  6673. Hello...
  6674.  
  6675. Have had your v.32bis modem for a month, I guess, and I'm very happy with it.
  6676. The only major problem that I've had is with connecting to some (not all)
  6677. remote USR Dual Standards.  The problem is always the same:  the modems appear
  6678. to negotiate v.32 or v.32bis, appropriately, but no CONNECT message is ever
  6679. sent to my computer.  The modem's display seems to be correct; in other words,
  6680. it seems to think it got it right.  On some occasions, I get a massive amount
  6681. of (very speedy) garbage, but still no CONNECT message of any sort.
  6682.  
  6683. This is the only real problem I've had, apart from a few that are to be
  6684. expected and are explainable.  Like, for example, the awful connect I got to
  6685. your board before I called back with the modem restricted to 2400.  I could
  6686. tell just from the speaker that there's a HUGE volume drop happening somewhere
  6687. between my location and yours.
  6688.  
  6689. Are you aware of such a problem with USR Duals?  I'm aware that this might be a
  6690. problem with the Duals, not with your (my) Supra v.32bis, so that's why I'm not
  6691. foaming at the mouth like I should be doing...
  6692.  
  6693. Thanks for your attention; I'll call back in a couple of days and see what
  6694. you've got to say.  Keep up the good work...
  6695.  
  6696. R. Barnhardt.
  6697.  
  6698.  
  6699. Msg#: 1287 *MODEM*
  6700. 06-26-92 09:18:58
  6701. From: ROB ROSENHOUSE
  6702.   To: SYSOP
  6703. Subj: UPGRADE
  6704. Hi Nathan, Can you verify my name on your upgrade list?  I am a sysop, and need
  6705. this chip at the earliest time frame.
  6706.  
  6707. Thank you, Rob Rosenhouse, 142 Speedwell Ave. - Apt 1, Morristown, NJ  07960
  6708.  
  6709.  
  6710.  
  6711. Msg#: 1310 *MODEM*
  6712. 06-26-92 21:24:18
  6713. From: ERNIE EVANUSH
  6714.   To: SYSOP
  6715. Subj: WARRANTY CARDS
  6716. Just wondered if you could help me with a question.....I bought a Supra fax
  6717. modem v32bis and didnt get no warranty or registration cards with it....I guess
  6718. just a name and number on a piece of paper will do the job....will it..
  6719.  
  6720.  
  6721. Msg#: 1319 *MODEM*
  6722. 06-27-92 00:44:12
  6723. From: MARK WHITE
  6724.   To: ERNIE EVANUSH
  6725. Subj: REPLY TO MSG# 1310 (WARRANTY CARDS)
  6726. Correct, drop us a note with your name & address, product and serial number. 
  6727.  
  6728. Mark - Supra Tech Support
  6729.  
  6730.  
  6731. Msg#: 1321 *MODEM*
  6732. 06-27-92 00:51:17
  6733. From: GRAHAM BREEZE
  6734.   To: SYS OP
  6735. Subj: SUPRAFAX V.32BIS
  6736. I've just received my modem today. It was working fine for about two hours. I
  6737. left it to receive several faxes and when i came back I tried to log onto
  6738. several services that I'd logged onto earlier, however I'm unable to dial out.
  6739. I'm unable to get the modem to go off hook for either faxes or data
  6740. transmission. I've checked the line but the modem just doesn't seem to
  6741. recognize that a line is there, i.e No Carrier.I'm actually using a line that
  6742. is connected through it right now so pass through is o.k. We've tried two other
  6743. lines, and one other computer with no success. I've disabled all inits and have
  6744. reset the modem numerous times. All this and I'm trying to show others in the
  6745. networking group there are attractive alternatives to Hayes products. I need
  6746. help A.S.A.P. as I'm supposed to be presenting your product early next week.
  6747. Please feel free to contact mer via America Online, "Breeze2", or on my home
  6748. phone 1 408 733 6133. Thanks Graham Breeze
  6749.  
  6750. No more messages in section *MODEM*
  6751.  
  6752. Reading Message Board *IBM*
  6753. Section has 34 Msgs, #350 to 1324 
  6754.  
  6755. Starting number, <CR>=First: 
  6756.  
  6757.  
  6758. Msg#:  350 *IBM*
  6759. 06-01-92 00:03:07
  6760. From: MARK WHITE
  6761.   To: JAMES TAKACS
  6762. Subj: MICROPHONE
  6763. Software Ventures does have one of our modems.  You should be able to get ahold
  6764. of a driver from SVC's BBS.
  6765.  
  6766. [Mark] Surpa Tech Support
  6767.  
  6768.  
  6769. Msg#:  386 *IBM*
  6770. 06-02-92 10:17:45
  6771. From: CHRISTIAN LANGLOIS
  6772.   To: TECH SUPPORT
  6773. Subj: HAYES V 9600
  6774.  
  6775.  
  6776. I am having problems with this editor, anyway aprt from that. Are there any
  6777. settings required to connect properly to the HAYES V 9600 modem ? Christian
  6778.  
  6779. aaa n H
  6780.  
  6781.  
  6782. Msg#:  403 *IBM*
  6783. 06-02-92 17:17:31
  6784. From: SYSOP
  6785.   To: BRAD STRUM (Rcvd)
  6786. Subj: ZMODEM
  6787. Brad, It sounds like the modem is not being initialized properly.  I'm not sure
  6788. what you're doing with those bat files.  What you need to do is set Procomm to
  6789. 19,200.  Then, from the terminal screen, initialize the modm with (AT &F2 &W)
  6790. The &W saves this into the modems stored configuration, so you should only have
  6791. to do this once.   [Nathan]  Supra Technical Support
  6792.  
  6793.  
  6794. Msg#:  448 *IBM*
  6795. 06-03-92 19:27:05
  6796. From: BRAD STRUM
  6797.   To: SYSOP (Rcvd)
  6798. Subj: REPLY TO MSG# 403 (ZMODEM)
  6799. The modem was configured already, and everything else works fine--Xmodem,
  6800. Ymodem, Ymodem-G, single and batch. I just can't get the external protocols to
  6801. work. Any ideas?
  6802.  
  6803.  
  6804. Msg#:  408 *IBM*
  6805. 06-02-92 19:54:18
  6806. From: GREG WALKER
  6807.   To: ALL
  6808. Subj: TELIX AND SUPRAFAX V.32BIS
  6809. I received my SupraFax V.32bis modem a few weeks ago. I'm having problems with
  6810. Telix not wanting to connect with a 2400 bps modem of which I sysop a club bbs
  6811. from remotely. Does anyone know the init string needed for Telix so i can
  6812. connect with any bbs. Right now I'm stuck using Mirror to connect with this
  6813. 2400 bps bbs. The init string I'm using in Telix is AT&F2 . It works fine with
  6814. the high speed modem I call. I really dislike the Mirror comm program that came
  6815. with the modem. Any suggestions would be appreciated. Thanks,
  6816.   
  6817. Greg
  6818.  
  6819.  
  6820. Msg#:  526 *IBM*
  6821. 06-06-92 21:53:04
  6822. From: BRIAN DHATT
  6823.   To: GREG WALKER
  6824. Subj: REPLY TO MSG# 408 (TELIX AND SUPRAFAX V.32BIS)
  6825. To connect with 2400 bps systems that hang up before your modem has a chance to
  6826. step down to 2400, type AT N S37=6.  Then after you are done with this BBS,
  6827. type ATN1.  These are not init strings, rater commands to type while in
  6828. terminal mode.
  6829.  
  6830.  
  6831. Msg#:  464 *IBM*
  6832. 06-04-92 10:35:56
  6833. From: JEFFREY R. BROIDO
  6834.   To: MARK WHITE (Rcvd)
  6835. Subj: MY SPEAKER.
  6836. Mark,
  6837.         I've been leaving messages here and by phone and haven't a reply. The
  6838. speaker in my brand new Supra V.32bis modem just went intermittant. If I press
  6839. gently on the diaphragm is sometimes restores it momentarily. I believe that
  6840. there's an open in the coil.
  6841.         Anyhow, I'd love it if you'd:  a) send me a new speaker, b) sell me a
  6842. new speaker (could it cost you more than $0.79?) or c) tell me where I can buy
  6843. one or d) give me the specs so I can find my own.[A
  6844.         Please respond here, at (908) 298-5563 during east coast working hours
  6845. today or tommorow, at home at (201) 455-0362 or just send the thing along to:
  6846. Jeffrey R. Broido
  6847.                 104 Mills St.
  6848.                 Morristown, NJ  07960-3722 I'd really appreciate any kind of
  6849. response.  I know you folks are busy, and I understand that, but nobody likes
  6850. to be ignored.  Incidentally, you might try to get through to your tech support
  6851. number lately.  Thanks in advance for your help.
  6852.                                                 jeff
  6853.  
  6854.  
  6855. Msg#:  501 *IBM*
  6856. 06-06-92 07:14:56
  6857. From: MARK WHITE
  6858.   To: JEFFREY R. BROIDO (Rcvd)
  6859. Subj: REPLY TO MSG# 464 (MY SPEAKER.)
  6860. We have an exchange program that if you can give us a visa or mastercard
  6861. number, we will Red Lable a new modem to you.  (1-3 days after we receive the
  6862. info).  In the packaging, there is a FedEx return envelope that is already
  6863. filled out.  Simply put the old modem in it, call FedEx, and they will pick it
  6864. up.  All of the shipping is handled by us, and we do not charge the credit card
  6865. unless we do not receive the old modem back in a few weeks.
  6866.  
  6867. Mark Supra Tech Support
  6868.  
  6869.  
  6870. Msg#:  623 *IBM*
  6871. 06-09-92 19:50:47
  6872. From: JEFFREY MORRIS
  6873.   To: SYSOP (Rcvd)
  6874. Subj: PROBLEM WITH PROCOMM
  6875. . I just received my Supra FaxModem 14.4 (v.32bis) and am experiencing a rather
  6876. annoying problem running under ProComm Plus and/or RoboComm. The problem is
  6877. that, although the modem is responding to busy signals by hanging up, it
  6878. doesn't seem to be getting the "BUSY" result code back to the software
  6879. properly--both ProComm and RoboComm just keep on ticking off seconds until they
  6880. time out.  I am using all settings as described in the  manual.
  6881.  
  6882. Any suggestions? I am using a 386SX-16 with a UART 16450 chip (for the time
  6883. being, at least).
  6884.  
  6885.  
  6886.  
  6887. Msg#:  755 *IBM*
  6888. 06-13-92 14:23:36
  6889. From: MARK WHITE
  6890.   To: JEFFREY MORRIS (Rcvd)
  6891. Subj: REPLY TO MSG# 623 (PROBLEM WITH PROCOMM)
  6892. What speed are you running the serial port at?
  6893.  
  6894. Mark - Supra Tech Support
  6895.  
  6896.  
  6897. Msg#:  906 *IBM*
  6898. 06-17-92 09:42:53
  6899. From: JEFFREY MORRIS
  6900.   To: MARK WHITE (Rcvd)
  6901. Subj: REPLY TO MSG# 755 (PROBLEM WITH PROCOMM)
  6902. I am running the serial port at 19200 since I don't have the 16550 UART yet.
  6903. However, I also tried at 9600 to no avail.
  6904.  
  6905.  
  6906.  
  6907.  
  6908. Msg#: 1060 *IBM*
  6909. 06-22-92 05:47:49
  6910. From: SYSOP
  6911.   To: JEFFREY MORRIS
  6912. Subj: REPLY TO MSG# 623 (PROBLEM WITH PROCOMM)
  6913. You should keep your port set at 19,200.  If the software is getting the busy
  6914. message, then it should work.  Makes sure that you are using 8 data bits, one
  6915. stop bit, and no parity.  Other than that, I'm not sure why it's not working. 
  6916. [Nathan]  Supra Technical Support
  6917.  
  6918.  
  6919. Msg#:  632 *IBM*
  6920. 06-10-92 01:12:45
  6921. From: DENNIS MCGRATH
  6922.   To: ALL
  6923. Subj: V.32BIS SUPRA (FAX-MODEM)
  6924. Help!!  I cannot get the V.32bis SupraFAXmodem to work in Telix above
  6925. 2400bps/arq, or locked at 9600 (no commpression/correction).  Does anyone out
  6926. there have yours working in telix?  Please reply to me here (I am also 1@7073
  6927. VirtualNET).  This is driving me nuts...
  6928.  
  6929.  
  6930. Msg#:  644 *IBM*
  6931. 06-10-92 15:49:37
  6932. From: JOE GONZALEZ
  6933.   To: SYSOP (Rcvd)
  6934. Subj: MODEMS WHAT IS THE PROBLEM
  6935. Ok I cant find a single message on this board probably the way its setup. Im
  6936. calling long distance from ENgland because everyone here is totally pissed with
  6937. the terrible connects from the v32b/fax. Just *WHAT* IS the problem??? why do
  6938. some connects work and some not. why is it nothing to do with type of modem? 
  6939. why do two supra's on the same exchange failt o connect.? why can i connect to
  6940. some HST DS but not others? why Cant i connect to THIS BBS without forcing
  6941. ats37=9??? JUST WHAT IS THE PROBLEM WITH THESE MODEMS. Can SOMEBODY PLEASE
  6942. ANSWER . I wroye a while back and got no reply. this is very expensive. I am a
  6943. buyer in england for First Chocie computers we oreder lost of tehse modems and
  6944. have to answer customers who ask the above questions? can SOMEONE PLEASE
  6945. ANSWER. Fidonet 2:256/301 or FAX +44 532 637689. We would like to continue
  6946. ordering supra v32b/fax but feel very unsure following the nationwide problems.
  6947.  
  6948.  
  6949. Msg#: 1067 *IBM*
  6950. 06-22-92 06:21:20
  6951. From: SYSOP
  6952.   To: JOE GONZALEZ
  6953. Subj: REPLY TO MSG# 644 (MODEMS WHAT IS THE PROBLEM)
  6954. Joe, You have to log on here at 9600 because of line noise on our system.  Many
  6955. of your customers may have to do the same thing.  This was not a problem with
  6956. 2400 and 9600 bps modems, but is just part of woring with high-speed V.32bis
  6957. modems.  They simply require cleaner lines than slower modems.  The new ROM
  6958. chips that will be available in mid-July will allow the Supra modem to initiate
  6959. the fall back signal under noisy line conditions.  This will make them easier
  6960. to use for most people.  Until then, simply set them to 12,000 or 9,600 when
  6961. dialing into a board with noisy lines. [Nathan]  Supra Technical Support
  6962.  
  6963.  
  6964. Msg#:  715 *IBM*
  6965. 06-12-92 21:34:04
  6966. From: BRUCE NUNNALLY
  6967.   To: SYSOP (Rcvd)
  6968. Subj: AFTER SUPRAFIX STILL CAN'T
  6969. I dl'd the suprafix.zip for the 32bis, and now the Winfax 2 seems to avoid some
  6970. of the problems from before.  Now, however, when I call a  fax machine my modem
  6971. reports cd, fx, etc., winfax says 'waiting', then the remote times out.  before
  6972. the fix, I could get about 80% into the  fax & freeze; I'd end up rebooting &
  6973. the remote would print a partial page.
  6974.  
  6975.  
  6976. Msg#:  837 *IBM*
  6977. 06-15-92 15:38:31
  6978. From: MIKE PRAGER
  6979.   To: BRUCE NUNNALLY (Rcvd)
  6980. Subj: REPLY TO MSG# 715 (AFTER SUPRAFIX STILL CAN'T)
  6981. Bruce, I had exactly the same problem. After quite a few calls, I got through
  6982. to the Supra Tech Support Dept. & the tech believed the new ROM would cure the
  6983. problem. If so, it should fix yours.
  6984. ...Mike Prager
  6985.  
  6986.  
  6987. Msg#:  841 *IBM*
  6988. 06-15-92 19:58:52
  6989. From: BRUCE NUNNALLY
  6990.   To: MIKE PRAGER (Rcvd)
  6991. Subj: REPLY TO MSG# 837 (AFTER SUPRAFIX STILL CAN'T)
  6992. Rats. I thought that this was an access to Supra... but if  I have to call the
  6993. tech line, I can.  Thanks for the resp;
  6994. I can receive faxes, but can't transmit.  
  6995.  
  6996.  
  6997. Msg#:  935 *IBM*
  6998. 06-18-92 07:11:53
  6999. From: MIKE PRAGER
  7000.   To: BRUCE NUNNALLY
  7001. Subj: REPLY TO MSG# 841 (AFTER SUPRAFIX STILL CAN'T)
  7002. Bruce-- this BBS does give you access to Supra. My observation, however, has
  7003. been that they are flooded with questions and it sometimes takes a while for
  7004. them to respond.  ...Mike
  7005.  
  7006.  
  7007.  
  7008. Msg#: 1107 *IBM*
  7009. 06-22-92 13:40:08
  7010. From: SYSOP
  7011.   To: BRUCE NUNNALLY
  7012. Subj: REPLY TO MSG# 715 (AFTER SUPRAFIX STILL CAN'T)
  7013. Yes, the new ROM chips will fix this problem.  And yes, this gives access to
  7014. Supra Technical Support.  I apologize for any delay in responding.  With
  7015. Winfax, you should try FAXing at 4800.  This works for 90% of the people with
  7016. this problem.  We will ship you the new ROMs in mid-July, free of charge,
  7017. provided that you have sent us your registration card. [Nathan]  Supra
  7018. Technical Support
  7019.  
  7020.  
  7021. Msg#:  727 *IBM*
  7022. 06-13-92 06:43:21
  7023. From: GREG HIVELY
  7024.   To: ALL
  7025. Subj: PCBOARD 14.5A
  7026. I have my new v32bis modem... it works great!!  I am really impressed!!  I am a
  7027. SysOp in WV I run PCBoard 14.5a . It's called The Blue Powder 304-727-6733...
  7028. Anyways... I gave it working with my software and "SEEMS" to do very well.. I
  7029. was just curious if anyone else out there had a String and setup for it so I
  7030. can compare....  Thanks!!!
  7031.  
  7032.            Greg Hively
  7033.  
  7034.  
  7035. Msg#:  849 *IBM*
  7036. 06-16-92 01:38:14
  7037. From: BILL PUETZ
  7038.   To: SYSOP (Rcvd)
  7039. Subj: MISC SETUPS
  7040. I wonder if you can provide some help for using the new FaxModem V.32bis with
  7041. CloseUp 4.0 and with the Shiva Netmodem/E.  I use  CloseUp for some support,
  7042. but I also need to attach to a couple of remote networks that use the Shiva
  7043. units for dial in.  They are also V.32bis units.  What is the simplest way to
  7044. connect?  Should one just enable the V.32bis and leave it at that?  At first, I
  7045. tried to select different modems in the individual setups for CloseUp and
  7046. Shiva, but that didn't work well.  In the absence of specifics, are there any 
  7047. V.32 or V.32bis modems that are close to yours?
  7048.    Finally, I noticed a message about the DOS package shipping -- what exactly
  7049. is that?  Oh, I actually just thought of two other questions. The first regards
  7050. another setup -- this time for using WordPerfect Works. They have the ability
  7051. to do communications and also faxing if the fax board supports something they
  7052. call "FaxBIOS" -- have you heard of this. Last question (really!):  does your
  7053. fax support the CAS standard?  We have some software that requires this, so
  7054. right now we use Intel boards, but I sure like your product and your support.
  7055. (We currently have five Dallas Fax units sitting on the shelf that don't work
  7056. and for which we have tried to get tech support for since December!!!
  7057.    Thanks for your help!
  7058.  
  7059.  
  7060. Msg#: 1174 *IBM*
  7061. 06-24-92 09:55:53
  7062. From: SYSOP
  7063.   To: BILL PUETZ
  7064. Subj: REPLY TO MSG# 849 (MISC SETUPS)
  7065. Bill, The best solution for your set-up is to not choose a modem type, and
  7066. initialize the modem with AT &F2.  If you must specify auto-answer, then you
  7067. also need AT S0=1.  The closest match to our modem is a Hayes Ultima 96.   Yes,
  7068. the modem will work with Microsoft Works terminal program.  It does not xupport
  7069. CAS, but does support Class 1 and Class 2, and Group 3.  Was that all?  If you
  7070. have any more questions, please let me know. [Nathan]  Supra Techncial Support
  7071.  
  7072.  
  7073. Msg#:  884 *IBM*
  7074. 06-16-92 14:47:17
  7075. From: JOE GONZALEZ
  7076.   To: SYSOP (Rcvd)
  7077. Subj: MODEMS
  7078. AGAIN>>> I am calling long distance from england. Will you *PLEASE* Reply to my
  7079. message in electronic mailbox addressed to all.
  7080.  
  7081.  
  7082. Msg#:  978 *IBM*
  7083. 06-19-92 13:06:22
  7084. From: TIMOTHY DEMAREST
  7085.   To: SYSOP
  7086. Subj: V.32BIS 14.4 SETUP
  7087. Sysop,
  7088.         I just received my v32bis 14.4 Faxmodem and really like it. 
  7089. Unfortunatley I cant get my modem to d/l text files any higher than 1000
  7090. characters per second. I am connecting at 9600, LAPM BLTZ. On my Multitech I
  7091. regularly get 1900 characters per sec. I have a 486 50Mhz, 16550 UART, baud set
  7092. for 19.2 and am using the default setup in the S registers in the modem. I am
  7093. using Procomm Plus and Crosstalk for Windows (which uses the 16550). Can you
  7094. give me a setup string that I can write to the memory and what modem I should
  7095. choose under Crosstalk for Windows or Procomm Plus?? Any help would be great. 
  7096. Tim Demarest
  7097.  
  7098.  
  7099. Msg#: 1033 *IBM*
  7100. 06-21-92 04:53:25
  7101. From: MICHAEL DONOHUE
  7102.   To: MARK WHITE (Rcvd)
  7103. Subj: V32BIS
  7104. Hi Mark
  7105.          Can you read a file I have just uploaded "SUPRARAM.MJD" as it is
  7106. easier this way right now and post your comments in the message base. Sorry for
  7107. the inconvience right now but only able to get 9600 right now with tons of
  7108. garbage on the lines as we are having big thunder storms and heavy rains,
  7109. Thanks.....
  7110.           
  7111.             Michael.....
  7112.  
  7113.  
  7114. Msg#: 1144 *IBM*
  7115. 06-23-92 00:58:37
  7116. From: MATTHEW ZUKOWSKI
  7117.   To: ALL
  7118. Subj: 16550AFN CHIP
  7119. I have a question dealing with the hi speed com chip..... Where do I get one.
  7120. Right now I think I am looking for a com board with the chip already installed
  7121. on it.  I am curently on a 386 33 ibm with 2 modems (one supra 14.4 and one
  7122. supra 2400) and also wish to get a mouse one of these days.  How much would I
  7123. expect to pay for com board???
  7124.  
  7125.  
  7126. Msg#: 1153 *IBM*
  7127. 06-23-92 12:37:38
  7128. From: DAVE GOBLE
  7129.   To: MATTHEW ZUKOWSKI
  7130. Subj: REPLY TO MSG# 1144 (16550AFN CHIP)
  7131. I just ordered a serial card with a 16550 chip (not sure if it is an AFN) for
  7132. $35 plus shipping.  Can't recall the company right off hand.  If you would like
  7133. the name and number let me know.
  7134.  
  7135. DaveG
  7136.  
  7137.  
  7138. Msg#: 1154 *IBM*
  7139. 06-23-92 12:43:28
  7140. From: DAVE GOBLE
  7141.   To: SYSOP
  7142. Subj: IBM BBS WITH A MCINTOSH CALLER
  7143. I am running a Maximus BBS with a Binkley front end with my new V.32bis Supra
  7144. modem.  One caller (a Mac user) gets garbage now since switching to the new
  7145. modem.  I hook up the old modem and he is back in business.  He connects at
  7146. 2400 and just gets a bunch of S's.  I don't change any settings when switching
  7147. modems.  All other callers connect on either modem.  Any clues?
  7148.  
  7149. Also, anyone have a setup string for the V.32bis running Binkley?  My current
  7150. one has quite a delay between connecting and sending out its "hit escape"
  7151. message to the caller.
  7152.  
  7153. DaveG
  7154.  
  7155.  
  7156. Msg#: 1260 *IBM*
  7157. 06-25-92 19:08:19
  7158. From: ALLEN MILLER
  7159.   To: ALL
  7160. Subj: PRODIGY SOFTWARE SETUP
  7161. Hello,
  7162.  
  7163. Could some one please tell me the right modem string to use with Prodigy
  7164. Software for Supra Faxmodem 14.4K.... 
  7165.  
  7166. - Allen
  7167.  
  7168.  
  7169. Msg#: 1269 *IBM*
  7170. 06-25-92 21:48:19
  7171. From: MARK WHITE
  7172.   To: ALLEN MILLER (Rcvd)
  7173. Subj: REPLY TO MSG# 1260 (PRODIGY SOFTWARE SETUP)
  7174. Until Prodigy is properly configured, it will not work correctly with our 
  7175. FaxModems.  ':AT&FE0' must be put on the last line of the file CONFIG.SM. 
  7176. (TeachText is a good program for this.)
  7177.  
  7178. From file CONFIG.SM
  7179.  
  7180. modem_str:249,017,a007040FA840040,2400,+++,CR,CRLF,1,4,6,N,30,50,3,6,32,N,N
  7181. ,,?,S 
  7182. 0,,S2,,,,S6,S7,,S9,S10,,S12,,,,,,,,,V1,Q0,,,,X1,,D,T,P,X1,H,,,,,,,,,,,,,,,O
  7183. K,0,C ONNECT,1,RING,2,NO CARRIER,3,ERROR,4,CONNECT 1200,5,NO
  7184. DIALTONE,6,BUSY,7,NO 
  7185.  
  7186.  
  7187. Msg#: 1270 *IBM*
  7188. 06-25-92 21:48:34
  7189. From: MARK WHITE
  7190.   To: ALLEN MILLER (Rcvd)
  7191. Subj: REPLY TO MSG# 1260 (PRODIGY SOFTWARE SETUP)
  7192. NECT 2400,10,,,,,,,,,:AT&FE0
  7193.  
  7194.  
  7195. Msg#: 1276 *IBM*
  7196. 06-25-92 23:35:26
  7197. From: JOE FERGUSON
  7198.   To: SYSOP
  7199. Subj: DIRECT CONNECTS
  7200. I just got my new Supra V32 from you on the sysop deal. I use Remote Access
  7201. 1.10 and Front Door 2.02. I run about 70 on line games (doors) and can't lock
  7202. my com port, as you and AT&F2 recommends. All baud rates work fine EXCEPT 14.4.
  7203. On this I get garbage at the remote end, I DO NOT have bad phone lines, and
  7204. connect with several other boards at 14.4 with no problems with my AT&T
  7205. Paradyne 6820. I work for AT&T paradyne as a Senior Field Engineer and am
  7206. fairly familiar with the AT command set. I have the following init string.
  7207.     ATH0S0=0M&KS48=128S36=1EX4&Q\N1%C&C1 <cr>
  7208.  Any suggestions on how to get a 14.4 connection or if not haw to only connect
  7209. at 9600 and below. Thanks !
  7210.  
  7211.  
  7212. Msg#: 1324 *IBM*
  7213. 06-27-92 05:40:19
  7214. From: JOE HENDERSON
  7215.   To: SYSOP
  7216. Subj: ERRATIC MODEM
  7217. Hi.  I received my SupraFAX Modem v.32bis about two weeks ago, but went on 
  7218. vacation and didn't have a chance to try it out until now.  I can't find my
  7219. warranty registration card either, but I have my original sales receipt from
  7220. Supra.  My problem is that when I power the modem on, the green LEDs flash an
  7221. interesting assortment of designs, while the speaker clicks, and the red LEDs
  7222. flicker.  It looks like something from an old Star Trek episode.  If it ever
  7223. does settle down to give me OK, the green LEDs still flicker.  If I try to dial
  7224. out, the modem will sometimes send long strings of spaces back to the comm
  7225. program, even if we aren't connected to anyone and the modem is still on-hook.
  7226. It even does this when I'm not trying to do anything with the modem.  My comm
  7227. program will be sitting there happy as a lark, not connected to anything, not
  7228. trying to connect to anything, then suddenly the modem lights do their dance
  7229. and the cursor starts zipping across the screen.  I can't get ahold of tech
  7230. support via the voice line.  Is there any way to get an RMA via this BBS?
  7231.  
  7232. Thanks, Joe Henderson
  7233.  