Copyright (C) Professional Power Cadd, Inc.
Version 6.5.0w
PARAMETERS INFORMATION FILE
This file contains parameters available and appropriate useage
information as can be used in your specific "params" file.
Note that all parameters must be specified in lower case characters.
serial#=
This number must be correct as assigned or the program will
not run.
windowloc=0
The window location parameter determines whether the menu is
located on the right or the left of the drawing area.
0 - menu is on right
1 - menu is on left
display=2
The display type parameter tells ProCadd about the users
particular requested display resolution. The default is type
2, or VGA. If your monitor is not VGA or better, the program
will fall back to an acceptable type. If you wish greater
resolution these types are available.
If selections 0 or 1 are used, the drawing area will be
severely reduced.
0 - CGA/EGA 640x200 4 - VGA 1024x768 (VESA)
1 - EGA 640x350 5 - VGA 1280x1024 (VESA)
2 - VGA 640x480 (default) 6 - VGA 1024x768 (C&T only)
3 - VGA 800x600 (VESA) 7 - Pixelworks Microclipper
pick_app=3
The value entered at this parameter tells ProCadd that any
point located by the user within "3" pixels of an element or
more specifically it's endpoint, should be interpreted as that
element or endpoint.
In cases where the user is operating with a display type above
800x600, the "pick_app=" should be at "4".
screen_height=9.5"
screen_width=12.5"
The screen height and width settings enable the user to
adjust the ProCadd drawing area so that real size is displayed.
The default settings are for a standard 17 inch monitor. When
setting these parameters for another, measure the usable
display area on that particular monitor.
efubufs=10
This buffers parameter determines how much memory that ProCadd
will set aside as a cache for entity file I/O.
-----------
user_units=
The "user_units=" parameter determines whether or not metric
units will be used in the program.
When "user_units=" is set to a value representing a metric unit
of measure, it can be considered to be in metric mode.
When in metric mode, the standard unit as defined as one is
centimeter instead of inch.
This mode affects operations including plotter functions,
dimension operations and text sizing.
When this parameter is set to "5", metric operation will not be
default and the standard unit will be one inch.
If this parameter is set to "2" and therefore metric operations
are desired, the user would probably also want to redefine the
"dimresol=" and dim_units=" parameters. These would change the
defaults in the Dimension functions to metric units and a
decimal resolution.
If the user has not specified any values at these related
parameters, the program will default to cm and 1/10 resolution.
Drawing is in metric format, the program will automatically flag
all files as metric unless either the status is switched at New
Drawing or a U.S. format saved drawing is retreived thereby
changing the internal flag to U.S.
The current values available for "user_units=" are:
user_units=2 - centimeters (metric)
5 - inches (U.S. Standard)
circle_chords=48
The value entered at this parameter determines the amount of
chords used to display circles or circular elements. The
more chords, the finer the curved representation. This does
not affect the plot.
resolution=1000.0
The resolution parameter value is used to assign display
resolution limits to the program. A default resolution is
1000 which determines that the least definable unit from the
display's standpoint is 1/1000 of the default unit of measure
which is one inch, or in the case of metric operation, one
centimeter.
min_window=250
This parameter value assigns a zooming limit to the program in
relation to the above mentioned resolution value. The value
250 interprets as 250/1000, or 1/4 inch or centimeter. This
value will be the smallest allowed window size.
bg_color=0
- Background Color (default 0 equals black)
fg_color=15
- Foreground Color (default 15 equals bright white)
frame_color=2
- Frame Color (default 2 equals dark green)
hi_color=10
- Highlight Color (default 10 equals bright green)
sel_color=14
- Select Color (default 14 equals yellow)
These parameters are used to select screen colors.
In cases where the user is operating with a laptop or monchrome
monitor or if the user would prefer a white background, we would
suggest the following color selections.
frame_color=0
fg_color=0
bg_color=7
hi_color=10
sel_color=14
drawings=$0\drawings
- default drawing file storage and retrieval location
symbols=$0\symbols
- default symbol file storage and retrieval location
stdparts=$0\stdparts
- default standard parts storage and retrieval location
session=$0\session
- default session files storage and retrieval location
fonts=$0\fonts
- default font files storage and retrieval location
plotters=$0\plotters
- default plotter driver retieval location
tmp=$session
- default tmp swap file location
entfile=$session\ent.ses
- default drawing entity file location
symfile=$session\sym.ses
- default symbol entity file location
params=$session\params
- default parameter file location
cadfile=
- instant load file identity
These parameters when changed, alter the default storage and/or
retrieval location for various file types.
file_sort=1
This parameter defines the initial default sort type when
entering the drawing, symbol and parts file management menus.
Value possibilities: 0 - no sort
1 - sort by name ascending
2 - sort by name descending
3 - sort by date ascending
4 - sort by date descending
5 - sort by size ascending
6 - sort by size descending
file_filter=1
This parameter deterines the default filter or no filter
setting
in the drawing, symbol and parts files management menus.
0 - default is "NO FILTER"
1 - default is "FILTER"
df_file_name_gen=0
- drawing file auto file name generation - 1=enabled
sym_file_name_gen=0
- symbol file auto file name generation - 1=enabled
sp_file_name_gen=0
- standard parts file auto file name generation - 1=enabled
colors=16
The value set at this parameter assigns the number of colors
available to the user at the Attributes and Plot menus.
color1pen=1
color2pen=1
color3pen=1
color4pen=1
color5pen=1
color6pen=1
color7pen=1
color8pen=1
color9pen=1
color10pen=1
color11pen=1
color12pen=1
color13pen=1
color14pen=1
color15pen=1
color16pen=1
The color?pen parameters set the default pen assignments as
displayed in the plot function menu.
structs=8
This parameter assigns the number of line structures allowed
as shown in Attributes and Plot.
bit_length=0.05
This parameter assigns a bit length value to be used in
defining structure types.
style2=.1,.1
style3=.2,.2
style4=.15,.1,.05,.1
style5=.1,.1,.1,.1,.3,.1
style6=.4,.4
style7=.3,.1
style8=.35,.05
The definitions as identified in these parameters display as
the defaults in the program.
text_size=0.1
This value represents the default text size in the program.
real_text=0
This parameter determines whether or not real text or fast text
will be default.
0 - "FAST TEXT" mode is default
1 - "REAL TEXT" mode is default
dim_arrow=0.1
This value represents the default arrow size used for
dimensions.
dim_units=6
This setting determines the default unit of measure for length
dimensions.
1 - millimeters
2 - centimeters (default in metric mode)
3 - meters
4 - kilometers
5 - inches
6 - feet/inches (default in U.S. mode)
dimmark=1
This parameter determines the dimension qualifier.
0 - unqualified
1 - tickmarks (default in U.S. mode)
2 - units of measure (default in metric mode)
dimfeet=1
When set at "1", the Dimension menu variable will default to
feet and inches. "0" will default to inches only.
dimresol=10
This parameter assigns the default minimum accuracy factor as
displayed in the Dimension menu.
maydrag=1
Set at "1" allows the "DRAG ALL" option. "0" disables it.
drag=1
Set at "1" defaults the option to "DRAG ALL". "0" defaults
the option to "DRAG BOX".
dim_color=14
- dimension color assignment (default 14 is yellow)
dim_text_color=14
- dimension color assignment (default 14 is yellow)
dim_witness_color=14
- witness line color assignment (default 14 is yellow)
paper_size=D
This parameter selection assigns the default paper size
selection in the Plot or Print menus.
orientation=0
This parameter assigns the default paper orientation in the
Plot and Print menus.
0 - landscape
1 - portrait
plottype=HP
This parameter assigns the default plotter driver.
beep=5
This value determines the number of beeps heard at the end of
plotting.
beep=\session\kotek3
beep=\session\kotek4
beep=\session\mary3
beep=\session\mary4
These tones sequences will be played following any previous
beep commands.
spline_points=0
When this parameter is "0", the points comprising the spline
path will display only when the spline is identified in the
Spline function. When set at "1", the points will always
display.
loadbnd=0
When this parameter is set to "1", all elements will be
enclosed by vertical and horizontal component boundary lines.
scale1=1.000000000,1:1
scale2=0.500000000,6"=1'
scale3=0.250000000,3"=1'
scale4=0.125000000,1-1/2"=1'
scale5=0.083333333,1"=1'
scale6=0.062500000,3/4"=1'
scale7=0.041666667,1/2"=1'
scale8=0.031250000,3/8"=1'
scale9=0.020833333,1/4"=1'
scale10=0.01562500,3/16"=1'
scale11=0.01041667,1/8"=1'
scale12=0.00781250,3/32"=1'
scale13=0.00833333,1"=10'
scale14=0.00166667,1"=50'
scale15=0.00083333,1"=100'
These parameter values are the definitions of the default
values as listed in the Plot or Print menus of the program.
width1=0.0
width2=0.0
width3=0.0
width4=0.0
width5=0.0
width6=0.0
width7=0.0
width8=0.0
These parameter values are the default line width definitions
as listed in the Attributes and Plot sections of the program.
When a value of "0.0" is entered, the program will understand