Save the edits made to the program entry point to the .ba file.
ntBpv
Change all of entry point's settings to their defaults. You still must choose 'Apply' to save the defaults settings.
Enter the name of the program entry point. This is the actual name of a function or sub-routine in your BASIC program. These names are not case-sensitive.
Choose whether the symbology passed to the hook is simply that which is stored in the element, or, the symbology that is determined after applying level-symbology, view-attributes, etc.
ntBoz
Choose whether this function should be called before or after other functions of this type that may already be installed.
This setting informs the system whether this function intends to modify the elements passed to it. It is safest to always leave this on.
ntBt4
If on, the entry point will be called during plots.
ntBtB
If on, the entry point will be called during view window updates.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
ntBt;
Determine the views for which the function will be active.
Pen Table Plot Element Hook|Called from Pen-Table section.
Pre-Plot Hook|Called just prior to plotting first element.
Post-Plot Hook|Called after plotting last element.
Plot Finished Hook|Called after plotfile is complete and closed.
Are you sure you want to delete the entry point '%s' ?
You can only have one entry point of this type per BASIC program and there is already one defined for this program.
Save source to
Saving to a directory is not allowed.
Cannot open macro source file.
Cannot write to macro source file.
Cannot load command table.
Cannot load editor dialog box.
Cannot initialize basic system.
Cannot open editor resource file.
Cannot open variable editor dialog box.
Compilation failed at line %d.
Execution failed at line %d.
Error:
Not enough memory to load macro source.
Open Basic Source File
Cannot save current buffer. Continue?
Cannot calculate size of source file.
Cannot read macro source file.
Cannot set a breakpoint at line %d.
Cannot create script object.
Cannot create thread object.
Completed successfully.
Received bad thread resume request.
Cannot resume thread.
Error reading macro source file.
Cannot find the macro source file.
Error opening macro source file.
Untitled
error: unknown var type
The macro has changed. Would you like to save your changes?
Not implemented yet
Macro source (.bas extension) was updated. Do you want to regenerate the compiled version of the macro (.ba extension) before proceeding?
Cannot find the Dialog Builder application
Error starting the Dialog Builder application
Cannot access .BA application file for this macro
There is not an active macro
Line:
Col:
The debugger has been stopped.
The debugger is active.
Cannot find .BA file.
<null string>
<array -
<user-defined type>
<object>
not initialized
There are no custom dialogs defined for this macro.
%s has been overwritten by another task. Reload with updated file?
This macro was compiled with an older version of the BASIC compiler. No source file is available for recompiling. Cannot proceed.
Cannot find the compiled form of the macro.
Cannot open the compiled form of the macro.
New Basic Source File
Completed search
String not found
A compiled version of the macro exists. Overwrite it?
The specified file is not text format. Cannot edit.
The compiled form of the macro (.BA extension) is a read-only file. The compiled update was not saved.
The maximum macro size is 65535 bytes (this macro is %d bytes). The macro cannot be compiled.
The macro source file was changed by another task. Do you want to overwrite the source file with the current buffer?
The debugger is running. Do you want to stop debugging in order to make the edit?
Letter range must be in ascending order
Redefinition of default type
Out of memory, too many variables defined
Type character doesn't match defined type
Expression too complex
Cannot assign whole array
Assignment variable and expression are different types
Identifier is not a array variable
Array type mismatch in parameter
Array type expected for parameter
Array type unexpected for parameter
Integer expression expected for an array index
Integer expression expected
String expression expected
Long expression expected
Invalid dialog element
Left of '.' must be an object, structure or dialog
Invalid string operator
Can't apply operator to array type
Operator type mismatch
'%s' is not a variable
'%s' is not an array variable or a function
Unknown %s '%s'
Out of memory
'%s': Too many parameters encountered
'%s': Missing parameter(s)
'%s': Type mismatch in parameter %s
Missing label '%s'
Too many nested statements
Encountered newline in string
Overflow in decimal value
Overflow in hex value
Overflow in octal value
Expression is not constant
Function name not explicitly typed or missing type character
No type characters allowed on parameters with explicit type
Missing type for variable
Can't pass an array by value
'%s' is already declared as a parameter
Variable name used as label name
Duplicate label
Not inside a function
Not inside a sub
Long expression expected
Can't assign to function
Identifier is already a variable
Unknown type
Variable is not an array type
Can't redimension an array to a different type
Identifier is not an string array variable
0 expected
Parameter 1: string expected
Parameter 2: string expected
Integer expression expected for file number
Unsubscripted array in expression
String variable expected for parameter 1
Expecting 0 or 1
Boolean expression expected.
Numeric expression expected
Numeric type FOR variable expected
For...Next variable mismatch
Out of string storage space
Out of identifier storage space
Internal error 1
Maximum line length exceeded
Internal error 3
Division by zero
Overflow in expression
Floating point expression expected
Floating point expression expected
Invalid floating point operator
Math error
Single character expected
Subroutine identifier can't have a type declaration character
Script is too large to be compiled
Variable type expected
Types and dialog variables can't be passed by value
Can't assign to user or dialog type variable
Maximum string length exceeded
Identifier name already in use as another type
Left of '.' must be an object, structure or dialog
Operator result on variant type is ambiguous
Operator cannot be used on an object
'%s' is not a property or method of the object
Type character on label
Type character mismatch on routine '%s'
Destination name is already a constant
Can't assign to constant
Error in format of compiler extensions
Identifier too long
Expecting string or structure expression
Can't assign to expression
Dialog and Object types are not supported in this context
Array expression not supported as parameter
Dialogs, objects and structures expressions are not supported as a parameter
Invalid numeric operator
Invalid structure element name following '.'
Access value can't be used with specified mode
Use the SET statement to assign objects
Invalid operator for object
Can't lset a type with a variable length string
Syntax Error
'%s' is not a method of the object
No members defined
Duplicate type member
Set is for object assignments
Type character mismatch on variable
Identifier already defined as a different type
Return without gosub
Illegal function call
Overflow
Out of memory
Subscript out of range
Divide by zero
Type mismatch
Out of string space
No Resume
Resume without error
Dialog needs End Dialog or push button
Out of stack space
Sub or Function not defined
Error in loading DLM
Bad DLM calling convention
Internal error
Bad file name or number
File not found
Bad file mode
File already open
Device I/O error
File already exists
Bad record length
Disk full
Input past end of file
Bad record number
Bad file name
Too many files
Device unavailable
Permission denied
Disk not ready
Cannot rename with different drive
Path/File access error
Path not found
Object variable not Set
Invalid pattern string
Only one user dialog may be up at any time
Dialog control identifier does not match any current control
The %s statement is not available on this dialog control type
The dialog control with the focus may not be disabled or hidden
Focus may not be set to a hidden or disabled control
Dialog control identifier is already defined
This statement can only be used when a user dialog is active
No timer available
No more DDE channels
No foreign application responded to a DDE initiate
Multiple applications responded to a DDE initiate
Foreign application won't perform DDE method or operation
Timeout while waiting for DDE response
User pressed Escape key during DDE operation
Destination is busy
Data not provided in DDE operation
Data in wrong format
Foreign application quit
DDE conversation closed or changed
Message queue filled; DDE message lost
DDE requires ddeml.dll
OLE Automation server cannot create object
Class does not support OLE Automation
OLE Automation server cannot load file
OLE Automation file or object name syntax error
OLE Automation object does not exist
Access to OLE Automation object denied
OLE initialization error
OLE Automation method returned unsupported type
OLE Automation method did not return a value
OLE Automation no such property or method%s
OLE Automation argument type mismatch%s
OLE Automation error%s
OLE Automation Lbound or Ubound on non-Array value
OLE Automation Object does not have a default value
Invalid Clipboard format
Can't empty clipboard
Can't open clipboard
Set value not allowed on collections
Get value not allowed on collections
Incorrect Windows version
Too many dimensions
Can't find window
Can't find menu item
Another queue is being flushed
Can't find control
Bad channel number
Requested data not available
Can't create popup menu
Message box canceled
Command failed
Network error
Network function not supported
Bad password
Network access denied
Network function busy
Queue overflow
Too many dialog controls
Can't find listbox/combobox item
Control is disabled
Window is disabled
Can't write to INI file
Can't read from INI file
Can't copy file onto itself
OLE Automation unknown object name
Redimension of a fixed array
Can't load and initialize extension
Can't find extension
User aborted macro.
Successful operation
Insufficient memory for operation
Can't find specified entry point
Invalid code (NULL handles in COMPCODE structure)
Compiler/runtime versions don't match
Error loading the compiler
Error loading the runtime
Error loading extensions
Error initializing the runtime
Entry point not same as requested type
An argument's type did not match
The argument count is different
Bad symbol table
Return argument's type does not match
Invalid array header
Cannot redimension a fixed array
Invalid number of dimensions
Unsupported data type
Error compiling the script
Unable to locate extension
Unable to resolve types during consolidation of public variable space
Syntax error during parsing
Specified variable was not found
Wrong type of object (ebHOBJECT) was passed in
Variable is wrong type for operation
Wrong number of dimensions appears in parse expression
One of the specified indexes is out of bounds
A variable is already defined as a different type
A variable is already defined with different dimensions
A user-defined type is defined differently in another script
Thread needs to be idle for this function
Toggle Breakpt
BASICDE
Step In
BASICDE
Step Over
BASICDE
BASICDE
Stop Debugging
BASICDE
Inspect Varbls
BASICDE
Set or clear a debugger breakpoint
Toggle Breakpoint
Execute the next line in the program, tracing into a subroutine if necessary
Step Into
Execute the next line in the program, stepping over subroutines
Step Over
Continue execution until complete or a breakpoint is encountered