home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
WADS of WADS
/
WadsOfWads.1994.zip
/
ZIPS
/
A_D
/
DMMET.ZIP
/
METRICS.TXT
Wrap
Text File
|
1994-08-24
|
9KB
|
205 lines
DOOM METRICS
------------
Scott Amspoker (scott@basis.com)
Creation of a successful Doom level requires that the PWAD designer be
aware of the "physical" sizes and limitations of the Doom world. On
a less critical level, the choice of wall, floor, and ceiling textures
will have some influence on room dimensions. This document is primarily
concerned with physical limitations. This document is not complete,
and as I explain below, it is not absolute either. I regret that
I haven't determined the map limits of a Doom level. The data structures
would appear to allow grid coordinates as well and floor/ceiling heights
from -32768..32767. However, map editors impose stricter limits.
To determine physical limitations, I created a simple level with
three sectors resembling this:
*-----------* *------------*
| | | |
| *---------* |
| | | |
| *---------* |
| | | |
*-----------* *------------*
By manipulating the height and width of the center sector I was able to
determine minimum clearances. While it was easy to perform tests with
"the player", it was a little trickier testing the various enemies.
I had to get an enemy to chase me through the center hallway. Unfortunately,
this does not lead to definitive results. If the width of the hallway is
near the minimum limit, the enemy is far less likely to enter the hallway
within a short period of time. This would give the false impression that
the hallway is already too narrow. I advise PWAD designers to allow extra
clearance if it is intended that enemies move easily from one sector to the
next.
After performing most of my tests, I received the April 13 version of
"The Unofficial Doom Specs" by Matt Fell. Unlike the earlier version I
had been using, this version provided the actual width and height of each
object. I found this useful in comfirming most (but not all) of my test
results and for filling in the missing data on the Spiderdemon which I
hadn't tested at all. (Many thanks to Matt for his invaluable contributions).
It appears that the minimum width through which an object will pass is greater
than the actual diameter of the object. For example, The 32-wide player
requires a width of 33 (although Fell reports a minimum width of 34). I
will list the physical dimensions as well as the minimum clearances I have
actually seen work. I left a value empty ("-") if I hadn't satisfactorily
established a minimum.
MINUMIM
ACTUAL CLEARANCE
OBJECT HEIGHT WIDTH HEIGHT WIDTH
------ ------ ----- ------ -----
Player 56 32 56 33
Trooper/Sarg 56 40 56 44
Imp 56 40 56 44
Demon/Spectre 56 60 56 64
Cacodemon 56 62 56 64
Lost Soul 56 32 56 -
Baron 64 48 64 -
Cyberdemon 110 80 110 -
Spiderdemon 100 256 - -
NOTE: Rising doors stop 4 units short of the neighboring ceiling. In order
to ensure the minimum doorway height of 56, the neighboring ceiling should
have a clearance of at least 60.
ANOTHER NOTE: When passing from one sector to the next, an object must
fit between the higher of the two floors and the lower of the two ceilings.
STEPS AND STAIRS
It appears that any creature with legs can step up as many as 24 units
at a time. (I haven't verified this with the Spiderdemon). As we all know,
the player can step down from any height. Enemies appear to be limited to
descending at most 24 units at a time. (Floating enemies aren't
constrained by steps).
Although a simple step up or down is easy to handle, stairways are
far more complicated. I figured that the depth of each step (the
distance front of one step to the front of the next step) had to
be a factor. The test results confirmed this but were confusing at
best.
The player can climb steps with a depth as *narrow as 1*! This could
be creatively used in PWADS since it would appear that the player is
scaling a sheer wall.
Enemies are much more picky about steps. For example, I discovered that
a trooper would descend stairs that had a minimum step depth of 33 with
the maximum riser height of 24. When I changed the riser height to some
smaller value, the mimimum required depth got smaller too. I gasped in horror
realizing the amount of work it would take to figure out the magic formula,
by trial and error, for each enemy. For what it's worth, the following
table shows the minimum observed depth for 24-unit risers. You can assume
these to be a safe values for any smaller riser. If your creatures
appear to be afraid of the stairs, try adjusting the riser to depth
ratio to create a kinder and gentler stairway. (I did not test the
Cyberdemon or the Spiderdemon in this area.)
OBJECT MINIMUM STEP DEPTH WITH 24-UNIT RISER
------ -------------------------------------
Trooper/Sarg 33
Imp 33
Demon/Spectre 51
Cacodemon N/A
Lost Soul N/A
Baron 41
Cyberdemon -
Spiderdemon -
WALL/ROOM DIMENSIONS
Unlike the physical limits described above, wall/room dimensions are
determined more by aesthetic factors than by numerical requirements.
However, in the absence of hard rules, there are magic numbers and standard
situations that come up from time to time. It is not practical to
cover every situation here. When in doubt, you should always
examine any of the stardard Doom levels for guidance. It is helpful
to always think in powers of 2. Doom level editors should provide
a user setable snap grid adjustable down to 8 units.
Room sizes are, of couse, entirely arbitrary. However, hallway and
corridor widths are commonly 64 or 128 units wide.
Most general wall textures are 128 x 128 units. The manner in which the
wall textures are rendered is described in a separate document (MANAGING
TEXTURES AND THE "UNPEGGED" ATTRIBUTE). The use of "unpegged" attributes
and X, Y offset modifiers enables the PWAD designer to satisfactorily use
these wall textures on any wall space.
Some of the available wall textures have more specific uses such as
doors, switches, decorations, and wall thickness filler. Doors
are usually 64 or 128 units wide. Door heights can vary. 72 units
seems to be a common door height in the standard Doom levels.
Decorations and switches normally appear on wall textures that are
64 units wide (a few are 128). When placing these textures on
non-standard wall widths, the decoration/switch will not appear centered
without adjusting the texture X-offset.
Wall thickness filler is used on the insides of door tracks, windows,
and the occasional alcove. Textures intended for such use normally 8 or 16
units wide but are designed to tile well with non-standard wall thicknesses
and heights.
Special stair riser textures are 8 and 16 units high. However, any
texture may be used on a stair riser.
FLOORS AND CEILINGS
-------------------
The textures used for floors and ceilings are all 64 x 64 units. Unlike
wall textures, floor and ceiling textures are aligned and oriented with
respect to the underlying map coordinate grid. Since these textures
are tiled globally, they will always create seamless transitions from
one sector to the next (assuming the adjoining sector has similar
floor/ceiling textures).
Some floor/ceiling textures have specific markings on them that are
important. For example, some ceiling textures have a grid of lights.
To ensure that the ceiling lights in a sector tile correctly, not only
must the sector size be a proper multiple of a single light, but the
sector itself must be placed on the map at an appropriate grid line.
A transporter pad has a special design. In order for the image
on the transporter pad to appear correct, the pad must be aligned on
a 64 x 64 map grid.
There are some special stair step textures (STEP1 and STEP2). These could
be used for the top surface of each stair. If you wish to use these textures
for your stairs, make sure you pick the texure with the proper north/south or
east/west orientation and snap your stairs to a 64-unit width and a
32-unit depth.
REAL WORLD SCALE
----------------
Occasionally, a PWAD designer wishes to create a Doom level based on
an actual place (such as his office building or home). I undertook such
a project using the actual blue prints as my reference. This creates
the problem of equating Doom measurement units to real world units.
There is no magic formula. The Doom engine does not appear to render
things with consistant aspect ratio. For my project, I found that the
following scale produced a satisfying result that "felt right" when
walking through the level:
16 Horizontal Doom units = 1 horizontal foot
10 Vertical Doom units = 1 vertical foot
You may wish to experiment with these values to suit your tastes. The
vertical scale seems to be the hardest to pin down. Heights look different
in Doom depending on whether the player is near or far from the feature in
question.