Interrupt List, part 10 of 10
This compilation is Copyright (c) 1989,1990,1991,1992,1993,1994 Ralf Brown
--------b-69---------------------------------
INT 69 - Zenith AT BIOS - ???
called by INT 09 handler
--------N-690100-----------------------------
INT 69 - DECnet DOS CTERM - INSTALLATION CHECK
AX = 0100h
Return: AL = FFh if present
SeeAlso: AX=010Fh
--------N-690101-----------------------------
INT 69 - DECnet DOS CTERM - SEND BYTE
AX = 0101h
BL = character
DX = session handle
Return: AH >= 80h on error
SeeAlso: AX=0102h
--------N-690102-----------------------------
INT 69 - DECnet DOS CTERM - READ BYTE
AX = 0102h
DX = session handle
Return: AH >= 80h on error
AH < 80h if successful
AL = character
SeeAlso: AX=0101h
--------N-690103-----------------------------
INT 69 - DECnet DOS CTERM - STATUS
AX = 0103h
DX = session handle
Return: AH status flags
bit 7 session has been aborted
bit 6 DECnet error
bit 1 trace data available
bit 0 receive data available
AL = reason code if DECnet error (see below)
SeeAlso: AX=0104h
Values for reason code:
00h normal disconnect
01h unknown message from host
02h protocol violation from host
03h could not process the initiate message
04h error receiving message from host
05h error sending message to host
06h error checking for message from host
07h remote system does not support CTERM
08h remote system does not support correct protocol version
09h did not receive BIND message from host
0Ah could not send BIND message to host
0Bh no more sessions available
0Ch session does not exist
0Dh not enough memory to complete operation
0Eh connection has broken
Index: error codes;DECnet DOS CTERM|DECnet DOS CTERM;error codes
--------N-690104-----------------------------
INT 69 - DECnet DOS CTERM - DECnet STATUS
AX = 0104h
DX = session handle
Return: AX = reason code (see AX=0103h)
Note: use this call when AX=0103h returns a DECnet error
SeeAlso: AX=0103h
--------N-690105-----------------------------
INT 69 - DECnet DOS CTERM - OPEN SESSION
AX = 0105h
DS:BX -> ASCIZ node name
ES:DX -> buffer for session control block (see INT 6A/AH=D0h)
Return: AX <= 0 on error
AX > 0 session handle
SeeAlso: AX=0103h,AX=0106h,AX=010Ah
--------N-690106-----------------------------
INT 69 - DECnet DOS CTERM - CLOSE SESSION
AX = 0106h
DX = session handle
Return: AH = 00h good close
other error code (see AX=0103h)
SeeAlso: AX=0103h,AX=0105h
--------N-69010A-----------------------------
INT 69 - DECnet DOS CTERM - GET SESSION CONTROL BLOCK SIZE
AX = 010Ah
Return: AX = length of session control block in bytes
SeeAlso: AX=0105h
--------N-69010B-----------------------------
INT 69 - DECnet DOS CTERM - GET DECnet SOCKET
AX = 010Bh
DX = session handle
Return: AX > 0 DECnet socket for the session
= 0 no match for handle
--------N-69010F-----------------------------
INT 69 - DECnet DOS CTERM - DEINSTALL CTERM
AX = 010Fh
Return: AH = 00h successful uninstall
other error code
Note: CTERM must have been the last TSR loaded in order to deinstall it
SeeAlso: AX=0100h
Index: uninstall;DECnet DOS CTERM
--------N-690A-------------------------------
INT 69 - DECnet DOS 2.1+ - DATA LINK LAYER
AH = 0Ah
AL = function (see below)
ES:BX -> Datalink Communication Block
Return: AX = status (see below)
SeeAlso: INT 6D"DECnet"
Values for function:
00h initialize
01h open portal
02h close portal
03h enable multicast address
04h disable multicast address
05h transmit
06h request transmit buffer
07h deallocate transmit buffer
08h read channel status
09h read datalink portal list
0Ah read information about a datalink portal
0Bh read and/or clear counters
0Ch request to boot from a network server
0Dh enable Ethernet channel
0Eh disable Ethernet channel
0Fh start MOP/send a System ID message
10h stop MOP
11h get DECPARM
12h set DECPARM
13h external loopback
Values for status:
00h successful
01h hardware failed to initialize
02h channel state was not off (must be off to execute that command)
03h channel state is off (must be on to execute that command)
04h address not set
05h hardware missing
06h buffer too small
07h no more buffers available
08h no more resources available
09h promiscuous receiver active
0Ah non exclusive
0Bh unrecognized portal
0Ch protocol type in use
0Dh not a valid Multicast address
0Eh outstanding calls
0Fh hardware doesn't support receiving bad frames
10h none outstanding
11h no events
12h broken
13h buffer quota exceeded
14h already initialized
15h loopback failure
Index: error codes;DECnet DOS|DECnet DOS;error codes
Format of Datalink Communication Block
Offset Type Description
00h WORD portal ID
02h 6 BYTEs source address
08h 6 BYTEs destination address
0Eh DWORD buffer pointer
12h WORD buffer length
14h WORD operation
16h BYTE pad flag (used on open)
00h no pad
01h pad
17h BYTE mode flag (used on open)
00h 802.3
01h Ethernet
02h promiscuous
18h DWORD line status change function
1Ch DWORD received data function
20h DWORD transmitted data function
24h BYTE maximum outstanding transmits/receives
25h 2 BYTEs protocol type
27h WORD buffers lost
--------N-694001-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4001h
Return: CF clear
AX = 0000h
ES:SI -> ???
Note: INT 69 is the default, and may be set to any interrupt from 60h-7Fh;
the signature "SYSV" immediately before the interrupt handler serves
as the installation check
SeeAlso: AX=4002h
Index: installation check;10NET SYSSVC
--------N-694002-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4002h
???
Return: ???
Note: INT 69 is the default, and may be set to any interrupt from 60h-7Fh;
the signature "SYSV" immediately before the interrupt handler serves
as the installation check
--------N-694101-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4101h
Return: CF clear
ES:SI -> ???
SeeAlso: AX=4102h,AX=4103h,AX=4104h
--------N-694102-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4102h
???
Return: ???
--------N-694103-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4103h
???
Return: ???
--------N-694104-----------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AX = 4104h
???
Return: ???
--------N-6942-------------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AH = 42h
AL = function (01h-14h)
???
Return: ???
--------N-6943-------------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AH = 43h
AL = function (01h-05h)
???
Return: ???
--------N-6944-------------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - ???
AH = 44h
AL = function (01h-03h)
???
Return: ???
--------N-6949-------------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - BUG
AH = 49h
Note: due to a fencepost error, this function branches to hyperspace
SeeAlso: AX=4001h,AH=FFh
--------G-696996-----------------------------
INT 69 - ISR.COM v1.00 - SPECIFY INTERRUPT HANDLER
AX = 6996h
DS:DX -> interrupt handler or 0000h:0000h to disable
Return: AX = 9669h
Program: ISR (Interrupt Service Reflector) is a TSR by Rich Bono which permits
a program to provide hardware interrupt handlers even while being
debugged with a debugger that swaps interrupt vectors during
debugging.
Note: the interrupt vector which is to be reflected is set at installation
time and cannot be changed
--------N-69FF-------------------------------
INT 69 - 10NET v5.0 - SYSSVC.COM - SIGNAL SYSTEM ERROR
AH = FFh
Return: never???
Notes: displays "System Error" message and register dump, then halts system
INT 69 is the default, and may be set to any interrupt from 60h-7Fh;
the signature "SYSV" immediately before the interrupt handler serves
as the installation check
SeeAlso: AX=4001h,AH=49h
--------U-6A---------------------------------
INT 6A - OPTHELP.COM
Program: OPTHELP is an optionally-resident help system for SLR Systems's OPTASM
assembler
Note: may be configured to use any interrupt from 60h to 7Fh (default 6Ah)
--------N-6A---------------------------------
INT 6A - DECnet DOS - LOCAL AREA TRANSPORT PROGRAM
Note: the installation check consists of testing for a signature area
immediately preceding the interrupt handler
SeeAlso: INT 6B"DECnet",INT 6D"DECnet"
Index: installation check;DECnet DOS Local Area Transport
Format of signature area:
Offset Size Description
-5 BYTE major version number
-4 BYTE minor version number
-3 3 BYTEs signature (ASCII "LAT")
--------N-6A0000-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - INSTALLATION CHECK
AX = 0000h
Return: AX = 4357h ('CW')
Program: Super-TCP is a TCP/IP protocol stack by Frontier Technologies Corp.
Note: an alternate installation check is to test for the ASCIZ signature
"FTC Super-TCP" three bytes past the interrupt handler
SeeAlso: AX=0001h,AX=0002h,AX=000Fh,AX=0010h,INT 61"PCTCP",INT 62"BW-TCP"
--------N-6A0001-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - ???
AX = 0001h
BH = function number
01h ???
DS:SI -> ??? 24-byte record1 (see below)
ES:DI -> buffer containing ???
02h ???
DS:SI -> ??? 18-byte record2 (see below)
ES:DI -> buffer containing ???
04h ???
BL = subfunction
01h
DS:SI -> ??? 28-byte record3 (see below)
ES:DI -> buffer containing ???
02h
DS:SI -> ??? 28-byte record3 (see below)
ES:DI -> buffer containing ???
03h
DS:SI -> ??? 28-byte record3 (see below)
else Return: AX = 0005h
05h ???
DS:SI -> ??? 20-byte record4 (see below)
ES:DI -> buffer containing ???
06h ???
BL = subfunction
01h
DS:SI -> ??? 40-byte record5 (see below)
02h
DS:SI -> ??? 20-byte record6 (see below)
ES:DI -> ???
03h
DS:SI -> ??? 20-byte record6 (see below)
04h
DS:SI -> ??? 46-byte record7 (see below)
else Return: AX = 0005h
11h ???
DS:SI -> ??? 28-byte record8 (see below)
ES:DI -> ???
Return: AX = function status
0000h successful
0005h unsupported function
000Ah out of memory
SeeAlso: AX=0000h
Format of record1:
Offset Size Description
00h 4 BYTEs ???
04h WORD size of ES:DI buffer
06h 18 BYTEs ???
Format of record2:
Offset Size Description
00h 4 BYTEs ???
04h WORD size of ES:DI buffer
06h 12 BYTEs ???
Format of record3:
Offset Size Description
00h 2 BYTEs ???
02h WORD ???
04h WORD size of ES:DI buffer
06h WORD ???
08h WORD operation number (for function 0401h)
0Ah DWORD -> ???
0Eh WORD (return) ???
10h 12 BYTEs ???
Format of record4:
Offset Size Description
00h 4 BYTEs ???
04h WORD size of ES:DI buffer
06h 14 BYTEs ???
Format of record5:
Offset Size Description
00h BYTE operation??? (00h-07h)
01h BYTE ???
02h WORD (return) ???
04h DWORD -> ???
08h 4 BYTEs ???
0Ch DWORD -> ??? or 0000h:0000h
10h 16 BYTEs ???
20h DWORD ???
24h 4 BYTEs ???
Format of record6:
Offset Size Description
00h 4 BYTEs ???
04h WORD size of ES:DI buffer
06h 14 BYTEs ???
Format of record7:
Offset Size Description
00h WORD ???
02h WORD ???
04h WORD ???
06h 40 BYTEs ???
Format of record8:
Offset Size Description
00h 4 BYTEs ???
04h WORD size of ES:DI buffer
06h 6 BYTEs ???
0Ch WORD (return) ???
0Eh WORD operation??? (01h-03h)
10h 12 BYTEs ???
--------N-6A0002-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - ???
AX = 0002h
BX = ??? (zero/nonzero)
CX = ??? identifier (see AX=0004h)
DS:SI -> 40-byte buffer for ??? or 0000h:0000h
ES:DI -> buffer for ??? or 0000h:0000h
Return: AX = 0000h (successful) ???
BL = ???
BH = ???
CX = ???
DX = ???
--------N-6A0003-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - GET ??? DATA AREA
AX = 0003h
Return: CX:DX -> data area (see below)
Format of data area:
Offset Size Description
00h 2 BYTEs ???
02h DWORD original INT 6A vector
06h 2 BYTEs ???
08h 96 BYTEs array of 16 6-byte ???
68h WORD number of elements of above array in use
6Ah WORD ???
???
--------N-6A0004-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - ALLOCATE ???
AX = 0004h
CX = size in ???
Return: AX = 0000h (successful)
CX = DX = ???
SeeAlso: AX=0005h,AX=000Fh
--------N-6A0005-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - FREE/CLOSE ???
AX = 0005h
CX = ??? identifier (from AX=0004h)
Return: AX = status (0000h successful, FFFFh failed)
SeeAlso: AX=0004h,AX=000Fh
--------N-6A000F-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - FREE/CLOSE ALL ???
AX = 000Fh
Return: AX = 0000h (successful)
SeeAlso: AX=0000h,AX=0004h,AX=0005h
--------N-6A0010-----------------------------
INT 6A U - Super-TCP DOS TSR Kernel v3.57 - UNINSTALL
AX = 0010h
Return: AX = status
0000h successful
0002h can't uninstall, interrupt vector hooked by another program
Program: Super-TCP is a TCP/IP protocol stack by Frontier Technologies Corp.
Note: if AX is not one of the values listed here on entry, Super-TCP
returns AX=FFFEh
SeeAlso: AX=0000h
--------N-6A01--DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - SEND BYTE
AH = 01h
DH = FFh
AL = character
DL = handle
Return: AH >= 80h on error
SeeAlso: AH=02h
--------N-6A02--DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - READ BYTE
AH = 02h
DH = FFh
DL = handle
Return: AH < 80h if successful
AL = character
AH >= 80h on error
SeeAlso: AH=01h
--------N-6A03--DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - STATUS
AH = 03h
DH = FFh
DL = handle
Return: AH = status flags (see below)
Bitfields for status flags:
bit 5 transmit buffer empty
bit 3 session in start state
bit 2 session not active
bit 1 unable to queue transmit data
bit 0 receive data available
--------N-6AD0--DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - OPEN SESSION
AH = D0h
DH = FFh
AL = FFh no password
= 0Fh password at ES:DI
ES:BX -> LAT session control block (see below)
ES:DI -> 16-byte blank-padded password
Return: AH = 00h success
DL = handle
SeeAlso: AX=D000h
Format of LAT Session Control Block:
Offset Size Description
00h 18 BYTEs service name
12h 18 BYTEs node name (future use)
24h 18 BYTEs port name (future use)
36h DWORD -> session stopped post routine
3Ah DWORD -> service table overflow post routine
3Eh DWORD -> transmit post routine
42h DWORD -> receive post routine
46h WORD session status
04h circuit failure
08h stop slot received
48h WORD slot state (LAT driver use)
4Ah WORD local credits (LAT driver use)
4Ch DWORD -> VCB (LAT driver use)
50h WORD backward slot (LAT driver use)
52h WORD forward slot (LAT driver use)
54h WORD remote slot ID (LAT driver use)
56h WORD local slot ID (LAT driver use)
58h WORD slot byte count (LAT driver use)
5Ah BYTE remote credits (LAT driver use)
5Bh 255 BYTEs transmitted data slot
15Ah BYTE number of receive data slots (4 recommended)
15Bh BYTE number of occupied slots
15Ch BYTE index of next receive slot to use
15Dh BYTE index of current receive slot
15Eh WORD pointer to first received character
160h N WORDs pointers to receive slots (buffers); each is 259 bytes
Note: set post routines to 0000h:0000h if polled operation will be used
--------N-6AD000DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - CLOSE SESSION
AX = D000h
DH = FFh
DL = handle
Return: AX = 0000h successful
= 0001h no such session
= 0002h session not running, try again later
SeeAlso: AH=D0h
--------N-6AD100DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - SEND BREAK
AX = D100h
DH = FFh
DL = handle
Return: AX = 0000h if successful
AH bit 7 set if unable to send break
--------N-6AD300DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - RESET LAT COUNTERS
AX = D300h
DH = FFh
SeeAlso: AX=D400h
--------N-6AD400DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - COPY LAT COUNTERS
AX = D400h
DH = FFh
CX = buffer size
ES:BX -> buffer for LAT counters
Return: AX = 0000h counters copied into buffer
= FFFFh buffer too small
SeeAlso: AX=D300h
--------N-6AD500DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - GET NEXT LAT SERVICE NAME
AX = D500h
DH = FFh
ES:BX -> 17-byte buffer for name
Return: AH = 00h if successful
ES:BX buffer filled
AX = FFFFh if end of table or no name available
Notes: use this function to get the names of the hosts on the network
successive calls are necessary to get all names
SeeAlso: AX=D600h
--------N-6AD600DHFF-------------------------
INT 6A - DECnet DOS LOCAL AREA TRANSPORT - LAT SERVICE TABLE RESET
AX = D600h
DH = FFh
Return: AX = number of service table entries
BX = 0000h service table has not overflowed
= FFFFh service table has overflowed
SeeAlso: AX=D500h
--------N-6B---------------------------------
INT 6B - DECnet DOS - PORT DRIVER
Note: the installation check consists of testing for a signature area
immediately preceding the interrupt handler
SeeAlso: INT 6A"DECnet",INT 6C"DECnet"
Index: installation check;DECnet DOS Port Driver
Format of signature area:
Offset Size Description
-5 BYTE major version number
-4 BYTE minor version number
-3 3 BYTEs signature (ASCII "PDV")
--------v-6B---------------------------------
INT 6B - VIRUS - "Saddam" - ORIGINAL INT 21h VECTOR
SeeAlso: INT 21/AX=FFFFh,INT 61"VIRUS",INT 70"VIRUS"
--------S-6B0000-----------------------------
INT 6B - Novell NASI/NACS, Ungermann-Bass Net One SERIAL I/O - BUFFERED WRITE
AX = 0000h
CX = length
ES:BX -> buffer
Return: CX = number of bytes written
Program: NASI is Novell's NetWare Asynchronous Services Interface which runs
on workstations; NACS is the NetWare Asynchronous Communications
Services module which runs on servers
Notes: one installation check consists of testing for the signature string
"NCSI" three bytes past the interrupt handler; see also AH=02h
this function is also supported by TelAPI, NPC NCSI, and Connection
Manager CLIENT.EXE; for TelAPI, nonzero values in AL specify a
connection ID
Connection Manager returns CF set/AL=FFh if called while an INT 6B
call is already in progress
SeeAlso: AX=0100h,AH=18h,INT 14/AH=19h,INT 14/AH=E3h
--------S-6B0100-----------------------------
INT 6B - Novell NASI/NACS, Ungermann-Bass Net One SERIAL I/O - BUFFERED READ
AX = 0100h
CX = length of buffer
ES:BX -> buffer
Return: CX = number of bytes read
Note: also supported by TelAPI and NPC NCSI; for TelAPI, nonzero values in
AL specify a connection ID
SeeAlso: AX=0000h,AH=19h,INT 14/AH=18h,INT 14/AH=E2h,INT 14/AX=FF02h
--------S-6B02-------------------------------
INT 6B - Novell NASI/NACS, Ungermann-Bass Net One SERIAL I/O - INSTALL CHECK
AH = 02h
AL nonzero
Return: AL = 00h if present and OK
Note: this function is also supported by TelAPI and NPC NCSI
SeeAlso: AX=0700h
--------S-6B0600-----------------------------
INT 6B - Novell NASI/NACS, Ungermann-Bass Net One SERIAL I/O - CONTROL
AX = 0600h
CX = command
02h send break
04h disconnect
06h hold
Return: CF clear if successful
AL = 00h
CF set on error
AX < 0
Note: this function is also supported by TelAPI and NPC NCSI
--------S-6B0700-----------------------------
INT 6B - Novell NASI/NACS, Ungermann-Bass Net One SERIAL I/O - GET STATUS
AX = 0700h
Return: CH <> 00h if connection active
Notes: this function is also supported by TelAPI and NPC NCSI
Novell TelAPI returns CX=FF01h and CF clear
SeeAlso: AH=02h,AH=10h
--------N-6B08-------------------------------
INT 6B - TelAPI - ???
AH = 08h
Return: CF clear
AL = 00h
CX = 0000h
Note: this function also clears ??? flag
SeeAlso: INT 14/AX=FF00h
--------S-6B10-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - GET STATUS
AH = 10h
AL = connection ID (Novell TELAPI.EXE)
CX = ???
Return: CF clear if successful
CL = ???
CH = ???
CF set on error
???
Note: this function is also supported by TelAPI
SeeAlso: AX=0700h,AH=12h,AH=1Fh
--------S-6B11--DX0001-----------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - ALLOCATE A VIRTUAL CIRCUIT
AH = 11h
DX = 0001h
AL = 00h
ES:BX -> service name string (8 characters, blank-padded)
Return: CF clear if successful
AL = virtual circuit number allocated (01h for Novell TELAPI.EXE)
CL = ??? (01h for Novell TELAPI.EXE)
CH = ??? (01h for Novell TELAPI.EXE)
CF set on error
???
Note: this function is also supported by TelAPI
SeeAlso: AH=12h,AH=15h,AH=16h,AH=17h,AH=18h
--------S-6B12-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - VIRTUAL CIRCUIT STATUS
AH = 12h
AL = virtual circuit number
CL = ???
ES:BX -> ???
Return: ???
Note: this function is also supported by TelAPI
SeeAlso: AH=10h,AH=15h,AH=1Ah,AH=1Bh,AH=1Fh
--------S-6B13-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - SET/RETRIEVE REQUEST/REPLY SERVICE NAME
AH = 13h
AL = virtual circuit number
CL = direction (00h get, nonzero set)
ES:BX -> buffer for/containing service name
Return: ???
Note: this function is also supported by TelAPI
SeeAlso: AH=14h,AH=15h
--------S-6B14-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - SET/RETRIEVE SERVICE ADDRESS
AH = 14h
AL = virtual circuit number
ES:BX -> buffer for/containing service address
Return: ???
Note: this function is also supported by TelAPI, which only supports
retrieving the address
SeeAlso: AH=13h,AH=15h,AH=21h
--------S-6B15-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - SET/RETRIEVE VIRTUAL CIRCUIT CONFIG
AH = 15h
AL = virtual circuit number
CL = direction (00h get, nonzero set)
ES:BX -> buffer for/containing virtual circuit config (see below)
Return: ES:BX buffer filled
Note: this function is also supported by TelAPI
SeeAlso: AH=13h"NCSI",AH=14h"NCSI"
Format of virtual circuit configuration:
Offset Size Description
00h WORD buffer length
02h WORD port ID
04h WORD receive rate
06h WORD receive word length
08h WORD receive stop bits
0Ah WORD receive parity
0Ch WORD transmit rate
0Eh WORD transmit word length
10h WORD transmit stop bits
12h WORD transmit parity
14h WORD DTR
16h WORD RTS
--------S-6B16-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - LOG AND/OR INITIALIZE VIRTUAL CIRCUIT
AH = 16h
AL = virtual circuit number
CL = ??? switch (00h, ???)
Return: CF clear if successful
AL = virtual circuit number
CF set on error
???
Note: this function is also supported by TelAPI, which always returns CF
clear and AL=00h
SeeAlso: AH=11h,AH=12h,AH=17h
--------S-6B17-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - DISCONNECT A VIRTUAL CIRCUIT
AH = 17h
AL = virtual circuit number
Return: CF clear if successful
CF set on error
???
Note: this function is also supported by TelAPI, which always returns CF
clear and AL=00h
SeeAlso: AH=11h,AH=16h
--------S-6B18-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - WRITE DATA ON A VIRTUAL CIRCUIT
AH = 18h
AL = virtual circuit number
CX = number of characters to send
ES:BX -> buffer containing characters to be sent
Return: CF clear if successful
CF set on error
???
Note: this function is also supported by TelAPI, which always returns CF
clear and AL=30h
SeeAlso: AX=0000h,AH=12h,AH=19h
--------S-6B19-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - READ DATA ON A VIRTUAL CIRCUIT
AH = 19h
AL = virtual circuit number
CX = number of characters to read
ES:BX -> buffer for received characters
Return: CX = 0000h if failed
CX = nonzero (possibly number of characters received) if successful
Note: this function is also supported by TelAPI
SeeAlso: AX=0100h,AH=12h,AH=18h
--------S-6B1A-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - RECEIVE STATUS
AH = 1Ah
???
Return: ???
SeeAlso: AH=12h,AH=1Bh
--------S-6B1B-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - TRANSMIT STATUS
AH = 1Bh
???
Return: ???
SeeAlso: AH=12h,AH=1Ah
--------S-6B1C-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - CLEAR RECEIVE BUFFER
AH = 1Ch
AL = circuit number
Return: nothing
SeeAlso: AH=1Dh"NCSI",AH=1Eh"NCSI"
--------S-6B1D-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - TRANSMIT BUFFER CONTROL
AH = 1Dh
???
Return: ???
SeeAlso: AH=1Ch,AH=1Eh
--------S-6B1E-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - ISSUE CONTROL REQUEST
AH = 1Eh
???
Return: ???
SeeAlso: AH=1Ch,AH=1Dh
--------S-6B1F-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - EXTERNAL STATUS
AH = 1Fh
???
Return: ???
SeeAlso: AH=10h,AH=12h
--------S-6B20-------------------------------
INT 6B - Connection Manager CLIENT.EXE - ???
AH = 20h
???
Return: ???
Program: Connection Manager by Softwarehouse Corp. permits the sharing of
serial ports over an IPX or NetBIOS-based network
Note: CLIENT.EXE returns CF set/AL=F9h if AH is not 00h to 21h on entry
--------S-6B21-------------------------------
INT 6B - NPC NCSI EXTENDED SERIAL I/O - QUERY NAME SERVICE
AH = 21h
AL = virtual circuit number
CL = ??? (00h or 01h)
ES:BX -> buffer for service name structure (see below)
Return: CF clear if successful
ES:BX buffer filled
CF set on error
Note: a program should call this function after allocating a virtual circuit
and check that the general name matches the requested service
SeeAlso: AH=14h"NCSI"
Format of service name structure:
Offset Size Description
00h WORD buffer length
02h 8 BYTEs service name
0Ah 8 BYTEs general name
12h 8 BYTEs specific name
----------6B6B-------------------------------
INT 6B - Tandy SCHOOLMATE PLUS - API
AH = 6Bh
AL = E0h to FFh
----------6C---------------------------------
INT 6C - system resume vector (CONVERTIBLE)
----------6C---------------------------------
INT 6C - DOS 3.2 Realtime Clock update
--------N-6C---------------------------------
INT 6C - DECnet DOS network scheduler
Notes: the installation check consists of testing for a signature area
immediately preceding the interrupt handler
also supported by DEC Pathworks for DOS
SeeAlso: INT 6B"DECnet",INT 6D"DECnet",INT 6E"DECnet"
Index: installation check;DECnet DOS scheduler
Format of signature area:
Offset Size Description
-5 BYTE major version number
-4 BYTE minor version number
-3 3 BYTEs signature (ASCII "SCH")
--------V-6D---------------------------------
INT 6D - VGA - internal
Note: used by IBM, Paradise, Video7, and NCR
--------V-6D---------------------------------
INT 6D - ATI VGA Wonder - VIDEO BIOS ENTRY POINT
points at the original INT 10 entry point set up by the ATI BIOS
SeeAlso: INT 10
--------V-6D---------------------------------
INT 6D - Trident SVGA - VIDEO BIOS HANDLER
Note: the BIOS INT 10 handler on various Trident VGA cards consists merely
of a call to INT 6D followed by an IRET.
--------N-6D---------------------------------
INT 6D - DECnet DOS (before 2.1) - DATA LINK LAYER PROGRAM
AH = function
???
Return: ???
Note: the installation check consists of testing for a signature area
immediately preceding the interrupt handler
SeeAlso: INT 69/AH=0Ah,INT 6C"DECnet",INT 6E"DECnet"
Index: installation check;DECnet DOS Data Link Layer
Format of signature area:
Offset Size Description
-5 BYTE major version number
-4 BYTE minor version number
-3 3 BYTEs signature (ASCII "DLL")
--------N-6E---------------------------------
INT 6E - DECnet DOS - DECnet NETWORK PROCESS API
Notes: this is the main DECnet DOS access, and is described in Digital manual
AA-EB46B-TV ("DECnet-DOS Programmer's Reference Manual")
there is a signature/data area immediately prior to the interrupt
handler which may be used as an installation check
Index: installation check;DECnet DOS
Format of signature area:
Offset Size Description
-5 BYTE major version number
-4 BYTE minor version number
-3 3 BYTEs signature (ASCII "DNP")
--------N-6F---------------------------------
INT 6F - Novell NetWare - PCOX API (3270 PC terminal interface)
AX = function
0000h enter terminal mode
Return: AX = status
0000h no action requested
0001h screen save
0001h reset interface and set configuration parameters
DX = bitfields
bits 2-0: model number
bits 4-3: I/O address
bits 6-5: DMA channel
Return: nothing
0002h set display parameters
DX = bitfields
bits 1-0: OIA mode
bits 4-2: monitor support
Return: nothing
0003h read status
Return: AX = status word (see below)
0004h read cursor position
Return: AX = cursor position
0005h get character from device buffer
DX = cursor position
Return: AH = type (00h data, 01h attribute)
AL = data or attribute character
0006h send character
DH = type (00h ASCII, 01h extended code)
DL = ASCII character or extended code
Return: nothing
0007h set timeout
DX = timeout in seconds
Return: nothing
0008h wait for location to be modified
DX = cursor position
Return: AX = status (0000h modified, nonzero timeout)
0009h NOP
000Ah restore display
Return: nothing
000Bh update device buffer
Return: AX = cursor positoin
000Ch write string to add information area
DS:DX -> string
Return: nothing
000Dh maintenance operations
DX = maintenance operation code
Return: AX = operation status
000Eh get control program version
Return: AH = release number (major version)
AL = level number (minor version)
000Fh get microcode version
Return: AH = release number (major version)
AL = level number (minor version)
0010h save or display graphics
BX = length of data buffer
CX = subfunction request code
DS:DX -> data buffer
Return: AX = return code
CX = length of PIF data
0011h perform structured field operation
CX = request number
DS:DX -> parameter list
Return: AX = status word (see below)
CX = error number
0012h set cursor position for direct write buffer
DX = new cursor position
Return: AX = status word (see below)
0013h write direct to buffer
DL = character to be written
DH = translation option
Return: AX = status word (see below)
0014h write direct to buffer without echo
DL = character to be written
DH = translation option
Return: AX = status word (see below)
0015h set direct write string length
DX = string value
Return: nothing
0016h write string direct to buffer
DS:DX -> string
Return: AX = status word (see below)
0017h write string direct to buffer, untranslated
DS:DX -> string
Return: AX = status word (see below)
0018h get direct-write cursor position
Return: AX = cursor position
0019h convert row/column to cursor position
DH = display row (1-43)
DL = display column (1-132)
Return: AX = cursor position
001Ah convert cursor position to row/column
DX = cursor position
Return: AH = display row
AL = display column
001Bh find next field
DX = initial cursor position
Return: AX = field cursor position
001Ch find previous field
DX = initial cursor position
Return: AX = field cursor position
001Dh find next unprotected field
DX = initial cursor position
Return: AX = field cursor position
001Eh find previous unprotected field
DX = initial cursor position
Return: AX = field cursor position
001Fh find next protected field
DX = initial cursor position
Return: AX = field cursor position
0020h find previous protected field
DX = initial cursor position
Return: AX = field cursor position
0021h masked search forward
DH = mask
DL = search pattern
Return: AX = cursor position or 0000h
0022h masked search backward
DH = mask
DL = search pattern
Return: AX = cursor position or 0FFFh
0023h find field length
DX = cursor position
Return: AX = field length
0024h read field
DS:DX -> buffer for field contents
Return: AX = status word (see below)
0025h read screen
DS:DX -> buffer for screen contents
Return: AX = status word (see below)
0026h read buffer untranslated
DX = cursor position
Return: AX = buffer code
CX:BX -> 3278/79 device buffer image
0027h enable/disable keyboard
DL = new state of keyboard breaks (00h enabled, 01h disabled)
Return: nothing
0028h select host session
DL = session short name
Return: AX = session information
0029h retrieve host session name
AX = short name (DFT) or 0000h (not available, CUT mode)
002Ah get current device buffer size
Return: AX = device buffer size
CX = segment of EAB
002Bh arm modified location trigger
DX = cursor position
Return: AX = status (0000h not available, 0001h successful)
Bitfields for status word:
bits 0,1 cursor type
bit 2 cursor inhibited
bit 3 display inhibited
bit 4 feature step inhibited
bit 5 480-character format code
bits 6,7 unused
bits 8-10 model number (2-5)
bit 11 unit has been reset by controller (bit cleared after status returned)
bit 12 buffer has been written into (bit cleared after status returned)
bit 13 alarm has been sounded (bit cleared after status returned)
bits 14-15 monitor type (01 mono, 10 color, 11 hybrid)
--------N-6F00-------------------------------
INT 6F - 10NET - LOGIN
AH = 00h
DS:DX -> login record (see below)
Return: CL = security level
AX = status (see below)
SeeAlso: AH=01h,AH=80h,INT 21/AX=4402h"10MEMMGR"
Format of login record:
Offset Size Description
00h 8 BYTEs user name
08h 8 BYTEs password
10h 12 BYTEs name of SuperStation
Values for status:
0000h successful
01FFh "RTO_NERR" transmit interrupt lost (time out on response)
02FFh "NET_NERR" network (hardware) error
03FFh "PAS_NERR" invalid password
04FFh "LRN_NERR" local resource not available
05FFh "SRN_NERR" server resource not available
06FFh "LNM_NERR" already logged in under different name
07FFh "LSF_NERR" login security failure (node)
08FFh "NLI_NERR" not logged in
09FFh "DIVZ_NERR" position calc error
0AFFh "NT1_NERR" receive subfunction not = send subfunction (i.e. read,write)
0BFFh "RFNC_NERR" request function not in range
0CFFh "NSFH_NERR" no more server file handle entries left
0DFFh "NFTAB_NERR" no more shared file table entries left
0EFFh "NUFH_NERR" no more user file handle entries left
0FFFh "CHAT_NERR" chat permit not on
10FFh "NSRV_NERR" not a server on request
11FFh "NOBD_NERR" no transporter board error
12FFh "STO_NERR" time out on send
13FFh "INF_NERR" item not found (spool item not on queue)
14FFh "DACS_NERR" DOS access incompatible
15FFh "RLOCK_NERR" record already locked
16FFh "IVP_NERR" invalid parameter
17FFh "RLTO_NERR" record lock time out error
18FFh "CSPL_NERR" currently spooling to named device
19FFh "DRP_NERR" dropped receive message (throttle)
1AFFh "SOPV_NERR" open sharing violation
1BFFh "NTUF_NERR" no more tuf entries left
1CFFh "NOWN_NERR" not file owner on open
1DFFh "RSEC_NERR" read security not passed
1EFFh "WSEC_NERR" write security not passed
1FFFh "GSEC_NERR" group security not passed
20FFh "SEC1_NERR" security file failure
21FFh "ACT1_NERR" activity file failure
22FFh "SPL1_NERR" spool control file failure
23FFh "NMT_NERR" device not mounted (spooling)
24FFh "RSPL_NERR" spool file has not been terminated
25FFh "DNSH_NERR" device not mounted or is not being shared
26FFh "DUP_NERR" duplicate node ID
27FFh "FNF_NERR" file not found error
28FFh "NMF_NERR" no more files
29FFh "UN_NERR" unknown internal system error
2AFFh "QCP_NERR" print queue is full or corrupted
2BFFh "IFNC_NERR" invalid function
2CFFh "IVH_NERR" invalid handle
2DFFh "TOF_NERR" too many files opened
2EFFh "PNF_NERR" path not found
2FFFh "SACT_NERR" named file is active
---10NET v5.0+ ---
30FFh "NAK_NERR" received NAK on send (destination out of buffers)
31FFh "RENT_NERR" reentrancy in driver F_SEND
32FFh "RECV_NERR" driver could not be put in receive mode
33FFh "NRLT_NERR" no more RLTAB entries left
34FFh "DIAL_NERR" function requires an unsupported dialect
35FFh "IVD_NERR" invalid device
36FFh "NALV_NERR" netname access level violated
37FFh "NPIDNF_NERR" network path not found
38FFh "SP_NERR" server is paused
39FFh "TMNM_NERR" too many remote user names
3AFFh "DUPD_NERR" duplicate network device
3BFFh "DIU_NERR" shared device in use, can't delete
3CFFh "NNWD_NERR" network name was deleted
3DFFh "NPFS_NERR" not enough space for print file
3EFFh "NNNF_NERR" network name not found (can't find the call name)
3FFFh "NB_NERR" network busy
40FFh "NDNLE_NERR" network device no longer exists
41FFh "NBCLE_NERR" NetBIOS command limit exceeded
42FFh "FINT24_NERR" Fail on INT 24h
43FFh "PEXP_NERR" password expired
44FFh "NPUP_NERR" new password error
45FFh "MAXS_NERR" maximum allowed disk space exceeded
46FFh "TDOW_NERR" time-of-day/day-of-week error
Index: error codes;10Net|10Net;error codes
--------N-6F01-------------------------------
INT 6F - 10NET - LOGOFF
AH = 01h
DS:DX -> superstation ID or nulls (12 bytes)
Return: CX = number of files closed
AX = status (see also AH=00h)
08FFh superstation ID not already logged in
SeeAlso: AH=00h,AH=81h
--------N-6F02-------------------------------
INT 6F - 10NET - STATUS OF NODE
AH = 02h
DS:DX -> 512-byte status record (see below)
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: INT 21/AX=5E01h"10NET"
Format of node status record:
Offset Size Description
00h 8 BYTEs user name (0 if none)
08h BYTE station type
00h workstation
01h superstation
02h gateway station
03h gateway active
04h logged into multiple superstations
05h reserved
09h 24 BYTEs list of superstations logged into more than one superstation
21h 12 BYTEs node ID
2Dh WORD message count for this station (send for user node, receive for
superstations)
---for superstations only---
2Fh WORD drives allocated (bit 0=A:, bit 1=B:,...)
31h BYTE user service flags (see below)
32h BYTE printers allocated (bit 0=LPT1,...)
33h BYTE number of unprinted spool files
34h BYTE number of opened files
35h BYTE number of logged on nodes
36h BYTE primary drive (1=A:)
37h BYTE reserved
38h N BYTEs list of logged on node IDs (each 12 bytes, max 37 IDs)
1F4h 3 BYTEs time: sec/min/hrs
1F7h 3 BYTEs date: day/mon/year-1980
Bitfields for user service flags:
bit 7 gate
bit 6 print permit on
bit 4 SUBMIT is on
bit 3 mail waiting for node
bit 2 calendar waiting for you
bit 1 news waiting for you
bit 0 mail waiting for you
--------W-6F0204-----------------------------
INT 6F C - MS Windows 3.0 - DOS APPLICATION SWITCH HOOK
AX = 0204h
Return: AX = status
0000h switch is allowed
other switch not allowed
Note: intercepting this call will allow a DOS application to ensure that
Windows will not switch away from it.
--------N-6F03-------------------------------
INT 6F - 10NET - GET ADDRESS OF CONFIGURATION TABLE
AH = 03h
DS:DI -> node ID (optional)
Return: ES:BX -> configuration table
SeeAlso: AH=13h,INT 21/AX=5E01h"10NET"
Format of configuration table:
Offset Size Description
-41 WORD local device table address
-39 WORD extended network error mapping table address
-37 WORD shared device table address
-35 WORD mounted device table address
-33 BYTE receive buffer counter
-32 BYTE collect buffer counter
-31 WORD TUF address
-29 BYTE enable flag
-28 BYTE FCB keep flag
-27 WORD reserved
---up to here, 10NET v3.3---
-25 WORD count of dropped Send6F
-23 WORD buffer start address
-21 WORD comm driver base address
-19 WORD send/receive retry count
-17 BYTE number of 550ms loops before timeout
-16 WORD UFH address
-14 WORD CDIR address
-12 WORD LTAB address
-10 WORD SFH address
-8 WORD FTAB address
-6 WORD RLTAB address
-4 WORD SMI address
-2 WORD NTAB address
00h WORD address of first CT_DRV
02h BYTE number of DRV entries
03h 8 BYTEs login name
0Bh 12 BYTEs node ID (blank-padded)
17h 6 BYTEs node address
1Dh BYTE flag
1Eh BYTE CT_CFLG (chat permit)
bit 1: sound bell
bit 0: CHAT permit
1Fh BYTE CT_PSFLG
bit 5: PRINT permit
bit 4: KB initiated
bit 3: CHAT called FOXPTRM
bit 2: SUBMIT active
bit 1: SUBMIT received
bit 0: SUBMIT permit
20h BYTE in 10Net flag
21h WORD receive message count
23h WORD send message count
25h WORD retry count
27h WORD failed count
29h WORD driver errors
2Bh WORD dropped responses/CHATs
2Dh 9 BYTEs LIST ID/NTAB address (3 entries--LPT1-3)
36h 6 BYTEs AUX ID/NTAB address (2 entries--COM1-2)
3Ch BYTE active CB channel
3Dh BYTE received 6F messages on queue
3Eh 9 BYTEs activity counters for channels 1-9
---beyond here, 10NET v3.3---
47h BYTE bit 0: RS232 gate
bit 1: Send6F gate (user set)
48h DWORD pointer into gate (user set)
4Ch DWORD pointer into 10Net send
50h N WORDs addresses of timer blocks
--------N-6F04-------------------------------
INT 6F - 10NET - SEND
AH = 04h
DS:BX -> send record (see below)
DS:DX -> data (max 1024 bytes)
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: AH=05h,AH=09h,AH=0Ah
Format of send record:
Offset Size Description
00h 12 BYTEs receiving node's ID
if first byte has high-order bit set, message is directed to
the CT_RGATE vector at the receiver
if second byte is 00h, first byte is taken as a CB
channel number and delivered to all nodes on same channel
0Ch WORD length of data at DX
--------N-6F05-------------------------------
INT 6F - 10NET - RECEIVE
AH = 05h
CX = number of seconds before timeout
DS:DX -> receive buffer (see below)
Return: CF clear if successful
AH = FEh if dequeued message is a CB message
CF set on error
AX = error code (see AH=00h)
SeeAlso: AH=04h
Format of receive buffer:
Offset Size Description
00h 12 BYTEs sending node's ID
0Ch WORD length of message
0Eh N BYTEs message (maximum 1024 bytes)
--------N-6F07-------------------------------
INT 6F - 10NET - LOCK HANDLE
AH = 07h
BX = file handle
CX:DX = starting offset in file
SI = record length
Return: CF clear if successful
CF set on error
AX = error code (see also AH=00h)
0002h file not found
SeeAlso: AH=08h,AH=0Fh,INT 21/AH=5Ch
--------N-6F08-------------------------------
INT 6F - 10NET - UNLOCK HANDLE
AH = 08h
BX = file handle
AL = mode
00h unlock all
01h unlock record at CX:DX
Return: CF clear if successful
CF set on error
AX = error code (see also AH=00h)
0002h file not found
SeeAlso: AH=07h,AH=0Fh,INT 21/AH=5Ch
--------N-6F09-------------------------------
INT 6F - 10NET - SUBMIT
AH = 09h
DS:BX -> submit record (see below)
SeeAlso: AH=04h
Format of submit record:
Offset Size Description
00h 12 BYTEs destination node ID (must be logged in)
0Ch WORD length+2 of following 'command line' text
0Eh N BYTEs command line text (<=100 bytes), system adds CR
--------N-6F0A-------------------------------
INT 6F - 10NET - CHAT
AH = 0Ah
DS:BX -> control parameters (see below)
DS:DX -> chat message (see below)
SeeAlso: AH=04h,AH=8Ah
Format of control parameters:
Offset Size Description
00h 8 BYTEs sender ID, defaults to node's userID if nulls
08h 8 BYTEs destination user ID, 'EVERYONE' may be used
10h 12 BYTEs destination node ID
Format of chat message:
Offset Size Description
00h WORD length+2 of following text
02h N BYTEs text, max 101 bytes
--------N-6F0B-------------------------------
INT 6F - 10NET - LOCK SEMAPHORE, RETURN IMMEDIATELY
AH = 0Bh
AL = drive number or 0
ES:SI = Ethernet address or 0
DS:BX -> 31-byte ASCIZ semaphore name
Return: AL = status (see below)
Note: same as INT 60/AH=12h
SeeAlso: AH=0Ch,INT 60/AH=12h
Values for status:
00h successful
01h semaphore currently locked
02h server not responding
03h invalid semaphore name
04h semaphore list is full
05h invalid drive ID
06h invalid Ethernet address
07h not logged in
08h write to network failed
09h semaphore already logged in this CPU
Index: error codes;10-Net|10-Net;error codes
--------N-6F0C-------------------------------
INT 6F - 10NET - UNLOCK SEMAPHORE
AH = 0Ch
AL = drive number or 0
ES:SI = Ethernet address or 0
DS:BX -> 31-byte ASCIZ semaphore name
Return: AL = status (see also AH=0Bh)
01h semaphore not locked
Note: same as INT 60/AH=13h
SeeAlso: AH=0Bh,INT 60/AH=13h
--------N-6F0D-------------------------------
INT 6F - 10NET - "WHO" - ENUMERATE USERS ON NETWORK
AH = 0Dh
AL = type code
01h return superstations only
02h return non-superstations only
otherwise return all
CX = length of data buffer
DS:DX -> array of records to be filled (see below)
Return: CL = number of records returned (responding stations)
SeeAlso: AH=16h,AH=8Dh
Format of station record:
Offset Size Description
00h 12 BYTEs node ID
0Ch BYTE flags
bit 1: workstation
bit 2: superstation
bit 3: xgate
bit 4: active gate
---if AL = 01h---
0Dh BYTE version number
0Eh WORD level number of 10Net software in responding node
---if AL = 02h---
0Dh 8 BYTEs user ID
15h BYTE version number
16h WORD level number
--------N-6F0E-------------------------------
INT 6F - 10NET - SPOOL/PRINT
AH = 0Eh
DS:DX -> spool/print record (see below)
Return: CF clear if successful
CF set on error
AX = error code (see also AH=00h)
17FFh device not mounted
18FFh already spooling to named device
Values for operation code:
0000h initiate spool
0001h abort print
0002h close spool
0003h delete spool
0004h print
0005h get report info
0006h set chat template
0007h queue
0008h return queue
0009h queue non-spooled file for printing
Format of Spool/Print record:
Offset Size Description
00h WORD operation code (see above)
02h 11 BYTEs file name in FCB format
---if operation code = 00h or 06h---
0Dh BYTE notification flags (see below)
0Eh BYTE days to keep (FFh=forever)
0Fh BYTE bits 0,1: device (1=LPT1)
bits 4-7: remote drive to store spool file (1=A,...)
10h WORD length of following data area
12h N BYTEs up to 64 bytes of description
---if operation code = 03h---
0Dh 8 BYTEs user ID to associate with filename
---if operation code = 04h---
0Dh WORD block number
0Fh 8 BYTEs user ID to associate with filename
---if operation code = 05h---
0Dh BYTE RRN to start retrieve
0Eh BYTE bits 0,1: local print device (LPTx)
bit 3: if set, return entries for all users
0Fh WORD length of following area
11h N BYTEs up to 1500 bytes to receive $SCNTL records returned
---if operation code = 07h---
0Dh BYTE queue number
0Eh BYTE bits 0,1: local print device (LPTx)
0Fh WORD number of bytes of test print to be done
11h BYTE code: 01h print device
02h test print count
03h prn
---if operation code = 08h---
0Dh BYTE queue location or $SCNTL location to start access
returns next item for access:
00h-7Fh queued items
80h-FEh non-queued, non-printed items
FFh no more items
0Eh WORD unused
10h WORD length of following area
12h N BYTEs up to 64 bytes to receive $SCNTL records
---if operation code = 09h---
0Dh 3 BYTEs unused
10h N BYTEs path to non-spooled file to be queued for printing
Bitfields for notification flags:
bit 7 queue to top
bit 6 do ID page
bit 5 no form feed
bit 4 reserved
bit 3 explicit queuing only
bit 2 notify at print completion
bit 1 notify server operator, with reply
bit 0 notify at print start
Format of $SCNTL record:
Offset Size Description
00h 8 BYTEs user ID
08h 11 BYTEs filename in FCB format
13h 6 BYTEs node ID
19h 3 BYTEs creation date
1Ch BYTE notification flags (see above)
1Dh BYTE retention time in days
1Eh BYTE printing device (LPTx)
1Fh 3 BYTEs date last printed (0 = never)
22h BYTE device containing spoolfile
23h WORD bytes to print for test print
25h WORD block number to start print
27h BYTE reserved
--------N-6F0F-------------------------------
INT 6F - 10NET v5.0 - "RM LOCK" - ???
AH = 0Fh
???
Return: ???
SeeAlso: AH=07h,AH=08h
--------N-6F10-------------------------------
INT 6F - 10NET - ATTACH/DETACH PRINTER
AH = 10h
AL = subfunction
00h initiate spooling if LPT1 is mounted
01h terminate spooling if LPT1 is mounted
SeeAlso: INT 21/AX=5D08h
--------N-6F11-------------------------------
INT 6F - 10NET - LOCK FCB
AH = 11h
AL = mode
01h sequential
02h random
03h random block
CX = number of records
DS:DX -> FCB (see INT 21/AH=0Fh)
Return: CF clear if successful
CF set on error
AX = error code (see also AH=00h)
0002h file not found
SeeAlso: AH=12h
--------N-6F12-------------------------------
INT 6F - 10NET - UNLOCK FCB
AH = 12h
AL = mode
00h sequential
01h random
02h random block
CX = number of records
DS:DX -> FCB (see INT 21/AH=0Fh)
Return: CF clear if successful
CF set on error
AX = error code (see also AH=00h)
0002h file not found
SeeAlso: AH=11h
--------N-6F13-------------------------------
INT 6F - 10NET v3.3+ - GET REMOTE CONFIGURATION TABLE ADDRESS
AH = 13h
DS:DX -> node ID, 12 bytes blank-padded
Return: CF clear if successful
ES:BX = configuration table address on given machine
CF set on error
AX = error code (see AH=00h)
SeeAlso: AH=03h
--------N-6F14-------------------------------
INT 6F - 10NET v3.3+ - GET REMOTE MEMORY
AH = 14h
BX:SI = address of remote memory
CX = length (<=1024 bytes)
DS:DX -> node ID, 12 bytes blank-padded
DS:DI -> area to receive remote memory image
Return: CF clear if successful
CX = amount of memory copied to DS:SI
CF set on error
AX = error code (see AH=00h)
--------N-6F1501-----------------------------
INT 6F - 10NET v3.3+ - GET SHARED DEVICE ENTRY
AX = 1501h
BX = zero-based index
DS:SI -> node ID, 12 bytes blank-padded
ES:DI -> 85-byte buffer for shared device table entry (see below)
Return: CF clear if successful
ES:DI buffer contains shared device table entry of BXth device
CF set on error
AX = error code (see AH=00h)
SeeAlso: AX=1502h,AX=1503h,AX=9501h
Format of shared device table entry:
Offset Size Description
00h 8 BYTEs device
08h 8 BYTEs alias
10h 64 BYTEs path
50h 8 BYTEs password
58h BYTE access
59h 4 BYTEs mask
--------N-6F1502-----------------------------
INT 6F - 10NET v3.3+ - SET SHARED DEVICE ENTRY
AX = 1502h
DS:SI -> node ID, 12 bytes blank-padded
ES:DI -> valid shared device table entry
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: AX=1501h,AX=1503h,AX=9502h
--------N-6F1503-----------------------------
INT 6F - 10NET v3.3+ - DELETE SHARED DEVICE ENTRY
AX = 1503h
BX = zero-based index
DS:SI -> node ID, 12 bytes blank-padded
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: AX=1501h,AX=1502h,AX=9503h
--------N-6F16-------------------------------
INT 6F - 10NET v5.0 - "GL WHO" - ???
AH = 16h
???
Return: ???
SeeAlso: AH=0Dh
--------N-6F17-------------------------------
INT 6F - 10NET v3.3+ - MOUNT
AH = 17h
AL = local drive number (0=A:)
BL = remote drive letter or '1'..'3' for LPTn or '4' or '5' for COMx
DS:DX -> node ID, 12 bytes blank-padded
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: AH=18h
--------N-6F18-------------------------------
INT 6F - 10NET v3.3+ - UNMOUNT
AH = 18h
AL = local drive number (0=A:)
BL = type
00h disk
01h-03h LPTn
04h,05h COMx
Return: CF clear if successful
CF set on error
AX = error code (see AH=00h)
SeeAlso: AH=17h
--------N-6F19-------------------------------
INT 6F U - 10NET v5.0 - AUDIT
AH = 19h
???
Return: ???
SeeAlso: AH=99h
--------N-6F1A-------------------------------
INT 6F U - 10NET v5.0 - "BULL" - ???
AH = 1Ah
???
Return: ???
--------N-6F1B-------------------------------
INT 6F U - 10NET v5.0 - "GMOUNT" - ???
AH = 1Bh
???
Return: ???
--------N-6F1C-------------------------------
INT 6F U - 10NET v5.0 - "GLOGIN" - GET LOGIN LIST
AH = 1Ch
???
Return: ???
--------N-6F1D-------------------------------
INT 6F U - 10NET v5.0 - "TABDATA" - ???
AH = 1Dh
???
Return: ???
--------N-6F1E-------------------------------
INT 6F U - 10NET v5.0 - "SCHED" - ???
AH = 1Eh
???
Return: ???
--------N-6F1F-------------------------------
INT 6F U - 10NET v5.0 - "WHOAMI" - ???
AH = 1Fh
???
Return: ???
--------N-6F20-------------------------------
INT 6F U - 10NET v5.0 - ???
AH = 20h
???
Return: ???
--------N-6F21-------------------------------
INT 6F U - 10NET v5.0 - ???
AH = 21h
???
Return: ???
--------N-6F22-------------------------------
INT 6F U - 10NET v5.0 - ???
AH = 22h
???
Return: ???
--------b-6F22--BP0012-----------------------
INT 6F - HP HIL Vectras - EXTENDED BIOS - READ CMOS MEMORY
AH = 22h
BP = 0012h (ID of V_SYSTEM driver)
BL = address of CMOS byte to read
Return: AH = status
AL = byte read
BP, DS destroyed
Note: supported by ES, QS, and RS series HP Vectras
SeeAlso: BP=0012h/AH=24h
--------b-6F24--BP0012-----------------------
INT 6F - HP HIL Vectras - EXTENDED BIOS - WRITE CMOS MEMORY
AH = 24h
BP = 0012h (ID of V_SYSTEM driver)
BL = address of CMOS byte to write
AL = new value
Return: AH = status
BP, DS destroyed
SeeAlso: BP=0012h/AH=22h
--------N-6F80-------------------------------
INT 6F - 10NET v5.0 - LOGIN
AH = 80h
DS:DX -> login record (see below)
Return: CF clear if successful
BL = number of days until password expires (00h = never)
CL = security level
CF set on error
AX = status (see AH=00h)
SeeAlso: AH=00h,AH=81h
Format of login record:
Offset Size Description
00h 8 BYTEs user name
08h 8 BYTEs password
10h 15 BYTEs server node ID
1Fh 8 BYTEs new password
27h BYTE invoke mode (00h command line, 01h interactive)
--------N-6F81-------------------------------
INT 6F - 10NET v5.0 - LOGOUT
AH = 81h
DS:DX -> server node ID (DX=0000h for universal logout)
Return: AX = status (see AH=00h)
SeeAlso: AH=01h,AH=80h
--------N-6F8A-------------------------------
INT 6F - 10NET v5.0 - CHAT
AH = 8Ah
DS:BX -> chat parameters (see below)
DS:DX -> chat message (see below)
Return: CF clear if successful
CF set on error
AX = status (see AH=00h)
SeeAlso: AH=0Ah
Format of chat parameters:
Offset Size Description
00h 8 BYTEs sender's user name
08h 8 BYTEs destination user name
10h 15 BYTEs destination node (0 if broadcast-style chat)
Format of chat message:
Offset Size Description
00h WORD message length
02h N BYTEs chat message contents
--------N-6F8D-------------------------------
INT 6F - 10NET v5.0 - "WHO" - ENUMERATE USERS ON NETWORK
AH = 8Dh
BX = service mask (see below)
CX = length of buffer
DS:DX -> buffer for array of Who data structures (see below)
Return: CF clear if successful
CX = number of nodes matching service mask
DS:DX buffer filled
CF set on error
AX = status (see AH=00h)
SeeAlso: AH=0Dh
Bitfields for service mask:
bit 0 workstation
bit 1 file server
bit 2 print server
bit 3 de-spool server
Format of Who data structure:
Offset Size Description
00h 8 BYTEs user name
08h 15 BYTEs node ID
17h 3 BYTEs unique portion of Ethernet address
1Ah BYTE Who group number
1Bh WORD service mask (see above)
1Dh DWORD serial number
21h BYTE maximum concurrent users with same serial number allowed on net
22h BYTE chat mask (see below)
23h BYTE internal system bits (see below)
24h 9 BYTEs version number in format MM.mm.xxx
2Dh BYTE number of shared directories
2Eh BYTE number of shared printer queues
Bitfields for chat mask:
bit 0 chat permitted
bit 1 bell enabled
bit 2 chat keyboard initiated
bit 3 in INT 16 handler
bit 4 in Get Input
bit 5 display has timed out
bit 6 chat is idle
Bitfields for internal system bits:
bit 0 submit permitted
bit 1 submit initiated
bit 2 submit executing
bit 3 internal client call/chat/spool/autospool
bit 4 in spool termination
bit 5 print permitted
bit 6 waiting for keyboard input
--------N-6F9501-----------------------------
INT 6F - 10NET v5.0 - GET SHARED DEVICE ENTRY
AX = 9501h
BX = zero-based index
DS:SI -> server's node ID
ES:DI -> buffer for shared device structure (see below)
Return: CF clear if successful
CF set on error
AX = status (see AH=00h)
SeeAlso: AX=1501h,AX=9502h,AX=9503h,AX=9504h
Format of shared device structure:
Offset Size Description
00h 8 BYTEs alias
08h BYTE type (02h modem, 03h print queue, 04h directory)
09h BYTE access rights
bit 0: read
bit 1: write
bit 2: create
0Ah 8 BYTEs password
12h 32 BYTEs comment
---directory---
32h 64 BYTEs pathname of shared directory
---print queue---
32h BYTE notification bit mask (see below)
33h BYTE job control bit mask (see below)
34h WORD number of days to retain file
36h WORD test print length
38h BYTE number of copies to print
39h BYTE compression algorithm
3Ah BYTE tab width (00h = don't expand)
3Bh BYTE priority
3Ch WORD time to open queue (FFFFh = always)
3Eh WORD time to close queue
40h WORD pause following queue switch, in clock ticks
42h WORD pause between print jobs, in clock ticks
44h BYTE associate queue file existence mask
bit 0: queue switch file exists
bit 1: initiate file exists
bit 2: abort file exists
45h 6 BYTEs character sequence for page eject
4Bh BYTE status of print queue
bit 0: queue is closed
4Ch WORD number of jobs on queue
4Eh WORD offset of next print job to be dispatched (FFFFh = none)
50h BYTE number of print devices in printer pool
51h WORD offset of first print device structure (FFFFh if empty)
Bitfields for notification flags:
bit 0 user at print start
bit 1 operator at start, with reply
bit 2 user at print completion
bit 3 operator at completion, with reply
bit 4 user on queue switch
bit 5 operator on queue switch, with reply
bit 6 user on print error
Bitfields for job control mask:
bit 0 print banner page
bit 1 eject page at end of job
bit 2 mark as "held" (queue but don't print)
bit 3 rush job (queue at top)
bit 4 overwrite file with zeros before deletion
bit 5 hyperspool if possible
--------N-6F9502-----------------------------
INT 6F - 10NET v5.0 - SET SHARED DEVICE ENTRY
AX = 9502h
DS:SI -> server's node ID
ES:DI -> shared device structure (see AX=9501h)
Return: CF clear if successful
CF set on error
AX = status (see AH=00h)
SeeAlso: AX=1502h,AX=9501h,AX=9503h,AX=9504h
--------N-6F9503-----------------------------
INT 6F - 10NET v5.0 - DELETE SHARED DEVICE
AX = 9503h
BX = zero-based index
DS:SI -> server's node ID
Return: CF clear if successful
CF set on error
AX = status (see AH=00h)
SeeAlso: AX=1503h,AX=9501h,AX=9502h,AX=9504h
--------N-6F9504-----------------------------
INT 6F - 10NET v5.0 - ENUMERATE USERS OF SHARED DEVICE
AX = 9504h
BX = zero-based shared device index
CX = zero-based user index
DS:SI -> server's node ID
Return: CF clear if successful
ES:DI -> node ID of the CX'th user of the BX'th device
CF set on error
AX = status (see AH=00h)
SeeAlso: AX=9501h,AX=9502h,AX=9503h
--------N-6F99-------------------------------
INT 6F - 10NET v5.0 - AUDIT
AH = 99h
DS:SI -> server's node ID
ES:DI -> data to be appended to audit trail file (max 106 bytes)
Return: CF clear if successful
CF set on error
AX = status (see AH=00h)
SeeAlso: AH=19h,AH=9Ch
--------N-6F9C-------------------------------
INT 6F - 10NET v5.0 - GET LOGIN LIST
AH = 9Ch
BX = zero-based index
Return: CF clear if successful
DS:DI -> BX'th node ID that caller's machine is logged into
CF set on error
AX = status (see AH=00h)
--------H-70---------------------------------
INT 70 - IRQ8 - CMOS REAL-TIME CLOCK
Desc: this interrupt is called when the real-time clock chip generates an
alarm or periodic interrupt, among others. The periodic interrupt
occurs 1024 times per second.
Nots: many BIOSes turn off the periodic interrupt in the INT 70h handler
unless in an event wait (see INT 15/AH=83h or INT 15/AH=86h).
may be masked by setting bit 0 on I/O port A1h
SeeAlso: INT 08,INT 0F"HP 95LX",INT 15/AH=01h"Amstrad",INT 15/AH=83h
SeeAlso: INT 15/AH=86h,INT 1A/AH=02h,INT 58"DESQview"
--------v-70---------------------------------
INT 70 - VIRUS - "Stupid" - ORIGINAL INT 21h VECTOR
Note: the virus sets this interrupt to be the same as INT 21, and then
performs only INT 70 calls; since INT 70 is also generated by the
real-time clock on the PC/AT and higher, this could cause random
actions on an infected system
SeeAlso: INT 6B"VIRUS",INT 9E"VIRUS",INT E0"VIRUS"
--------H-71---------------------------------
INT 71 - IRQ9 - REDIRECTED TO INT 0A BY BIOS
Notes: may be masked by setting bit 1 on I/O port A1h
the default BIOS handler invokes INT 0A for compatibility, since the
pin for IRQ2 on the PC expansion bus became the pin for IRQ9 on the
AT expansion bus.
under DESQview, only the INT 15h vector and BASIC segment address (the
word at 0000h:0510h) may be assumed to be valid for the handler's
process
SeeAlso: INT 0A,INT 59
--------H-72---------------------------------
INT 72 - IRQ10 - RESERVED
Note: may be masked by setting bit 2 on I/O port A1h
SeeAlso: INT 5A
--------H-73---------------------------------
INT 73 - IRQ11 - RESERVED
Note: may be masked by setting bit 3 on I/O port A1h
SeeAlso: INT 5B
--------H-74---------------------------------
INT 74 - IRQ12 - POINTING DEVICE (PS)
Notes: may be masked by setting bit 4 on I/O port A1h
under DESQview, only the INT 15h vector and BASIC segment address (the
word at 0000h:0510h) may be assumed to be valid for the handler's
process
SeeAlso: INT 33,INT 5C
--------H-75---------------------------------
INT 75 - IRQ13 - MATH COPROCESSOR EXCEPTION (AT and up)
redirected to INT 02 by the BIOS, for compatibility with the PC
Notes: may be masked by setting bit 5 on I/O port A1h
not all clones wire the coprocessor to generate this IRQ; some systems
generate an NMI (see INT 02) or assert the -ERROR pin on the CPU
(see INT 10"COPROCESSOR")
under DESQview, only the INT 15h vector and BASIC segment address (the
word at 0000h:0510h) may be assumed to be valid for the handler's
process
SeeAlso: INT 10"COPROCESSOR",INT 5D
--------H-76---------------------------------
INT 76 - IRQ14 - HARD DISK CONTROLLER (AT and later)
Note: may be masked by setting bit 6 on I/O port A1h
SeeAlso: INT 0E"IRQ6",INT 5E
--------H-77---------------------------------
INT 77 - IRQ15 - RESERVED (AT,PS)
Note: may be masked by setting bit 7 on I/O port A1h
SeeAlso: INT 5F
--------H-77---------------------------------
INT 77 - IRQ15 - POWER CONSERVATION (Compaq SLT/286)
Note: may be masked by setting bit 7 on I/O port A1h
SeeAlso: INT 15/AX=4600h,INT 5F
--------E-78---------------------------------
INT 78 - UofSalford DBOS DOS extender - API
AH = function
00h (PB) display 32-bit memory specified by command argument
01h (PT) display 32-bit instruction(s) specified by command arg
02h specify offset to subsequent PB and PT commands
03h switch to protected mode
DWORD following INT instruction point to map; protected-mode
entry point is immediately following the DWORD
Return: never
Note: if bit 31 of the map address is set, only a stub was
loaded by DOS and DBOS will load the entire program
04h specify that subsequent load (AH=03h) should leave program in
memory
05h release program from memory
06h set break point at address and option count from commandline
07h resume program execution
08h single-step program
09h set read/write breakpoint using 386 debug registers
0Ah set write breakpoint using 386 debug register
0Bh set memory byte to new value
0Ch display CPU registers
0Dh run until specified program address reached
0Fh print trace from program map
10h specify an offset using a map symbol
14h print memory without any offset
18h switch DBOS into/out of test mode (ON/OFF commandline args)
1Dh get address of real/protected-mode communication buffer
Return: ES:BP -> comm buffer
1Eh set real-mode memory size (specify how much real-mode memory
to leave free when running FTN77 programs)
22h uninstall DBOS
24h force DBOS to emulate coprocessor instructions
26h set named DBOS switches from commandline
27h reset named DBOS switched from commandline
2Ah set list of dynamic link libraries to contents of commandline
file
35h specify that subsequent load (AH=03h) should stop at first
instruction
Return: ???
Notes: DBOS supports functions 00h through 50h; many of these functions
provide a low-level debugging interface
command arguments are read from the calling program's PSP
SeeAlso: INT 79"DBOS"
Index: uninstall;DBOS DOS extender
--------E-78---------------------------------
INT 78 - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ0
Program: GO32.EXE is a DOS extender included as part of the 80386 port of the
GNU C/C++ compiler by DJ Delorie and distributed as DJGPP
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 08,INT 10/AH=FFh"GO32",INT 79"GO32"
--------A-78---------------------------------
INT 78 R - AutoCAD Device Interface - PLOTTER - SEND COMMAND
AX = function
0001h begin plot
BX = file level
0000h ASCII file
0001h binary file
0002h AutoCAD DXB file
0003h installed ADI driver
0002h end plot (close plotter)
0003h move (pen up)
BX = new X position
CX = new Y position
0004h move (pen down)
BX = new X position
CX = new Y position
0005h select pen
BX = pen number
0006h select drawing speed
BX = drawing speed N
0007h select line style
BX = line style N
0008h raise pen
0009h abort plot
Return: AX = 0000h (may be used for driver status in future releases)
SeeAlso: INT 79"AutoCAD",INT 7A/AX=0001h"AutoCAD",INT 7B/AX=8001h"AutoCAD"
--------d-78---------------------------------
INT 78 - ADP-60 IDE controller - ORIGINAL INT 13
SeeAlso: INT 79"ADP-60"
--------d-7800-------------------------------
INT 78 - TARGA.DEV - CMC International SCSI device driver - SET I/O PORT
AH = 00h
DX = interface board I/O port
Return: CF set on error
AL = error code (see below)
Note: if this routine is not called, the port is the driver's default
(usually 0280h or 0300h)
an installation check is performed by TARGA.DEV upon initialization
by checking for the string "SCSI" at offset 03h into the interrupt
handler
SeeAlso: AH=01h,AH=02h
Index: installation check;TARGA.DEV
Values for error code:
00h illegal command given to SCSI code
01h invalid I/O port specified (must be from 100H to 3F8H, and must be on
an 8-port boundary)
02h invalid DMA channel specified (must be from 1 to 3)
03h invalid SCSI board number specified (must be from 0 to 7)
04h error from data register test during self-test
05h SCSI input signals not all 0 when SCSI RST activated
06h SCSI input signals not all 0 before selecting a SCSI device
07h BSY signal is active; SCSI bus is busy
08h SCSI board not selected, BSY signal did not come on in response to
raising SEL
09h time-out waiting for status state, signifying end of DMA transfer
--------d-7801-------------------------------
INT 78 - TARGA.DEV - GET I/O PORT
AH = 01h
Return: DX = current interface board I/O port
SeeAlso: AH=00h,AH=03h"TARGA"
--------d-7802-------------------------------
INT 78 - TARGA.DEV - SET DMA CHANNEL
AH = 02h
AL = interface board DMA channel
Return: CF set on error
AL = error code (see AH=00h)
Note: if this routine is not called, the DMA channel is the driver's default
(usually 3)
SeeAlso: AH=00h,AH=03h"TARGA"
--------d-7803-------------------------------
INT 78 - TARGA.DEV - GET DMA CHANNEL
AH = 03h
Return: AL = current interface board DMA channel
SeeAlso: AH=01h,AH=02h
--------d-7804-------------------------------
INT 78 - TARGA.DEV - SET SCSI DEVICE NUMBER
AH = 04h
AL = SCSI device number
Return: CF set on error
AL = error code (see AH=00h)
Note: if this routine is not called, the device number used is the driver's
default (usually 0)
SeeAlso: AH=02h,AH=05h
--------d-7805-------------------------------
INT 78 - TARGA.DEV - GET SCSI DEVICE NUMBER
AH = 05h
Return: AL = current SCSI device number
SeeAlso: AH=03h"TARGA",AH=04h
--------d-7806-------------------------------
INT 78 - TARGA.DEV - SET/CLEAR EARLY RETURN MODE
AH = 06h
AL = 00h clear early return mode
= 01h set early return mode
Note: if early return mode is set then SCSI will return with no errors
when the last DMA transfer is started in a call with AH=13h or AH=14h
if this routine is not called, early return mode is cleared
SeeAlso: AH=13h,AH=14h,AH=15h
--------d-7808-------------------------------
INT 78 - TARGA.DEV - INTERFACE BOARD SELF-TEST
AH = 08h
Return: CF set on error
AL = error code (see AH=00h)
Note: the SCSI bus is also reset
SeeAlso: AH=09h
--------d-7809-------------------------------
INT 78 - TARGA.DEV - RESET SCSI BUS
AH = 09h
Return: AL = error code if carry set (see AH=00h)
SeeAlso: AH=08h
--------d-7810-------------------------------
INT 78 - TARGA.DEV - SEND SCSI COMMAND
AH = 10h
DS:SI -> command bytes
Return: AH = SCSI status byte
CF clear if successful
AL = SCSI message byte
CF set on error
AL = error code (see AH=00h)
SeeAlso: AH=11h,INT 21/AX=4403h"ST-01"
Format of SCSI Command:
Offset Size Description
00h BYTE length of command
01h ??? command bytes
--------d-7811-------------------------------
INT 78 - TARGA.DEV - SEND SCSI COMMAND, RECEIVE DATA (PROGRAMMED I/O)
AH = 11h
DS:SI -> command bytes
ES:BX -> data storage area
CX = number of data bytes to transfer
Return: AH = SCSI status byte
CF clear if successful
AL = SCSI message byte
CF set on error
AL = error code (see AH=00h)
Note: this command receives data internally one byte at a time
SeeAlso: AH=10h,AH=13h
Format of SCSI Command:
Offset Size Description
00h BYTE length of command
01h ??? command bytes
--------d-7812-------------------------------
INT 78 - TARGA.DEV - SEND SCSI COMMAND AND DATA (PROGRAMMED I/O)
AH = 12h
DS:SI -> command bytes
ES:BX -> data storage area
CX = number of data bytes to transfer
Return: AH = SCSI status byte
CF clear if successful
AL = SCSI message byte
CF set on error
AL = error code (see AH=00h)
Note: this command sends data internally one byte at a time
SeeAlso: AH=14h
Format of SCSI Command:
Offset Size Description
00h BYTE length of command
01h ??? command bytes
--------d-7813-------------------------------
INT 78 - TARGA.DEV - SEND SCSI COMMAND, RECEIVE DATA (DMA)
AH = 13h
DS:SI -> command bytes
ES:BX -> data storage area
DX:CX = number of data bytes to transfer
Return: AH = SCSI status byte (if early return mode is clear)
CF clear if successful
AL = SCSI message byte (if early return mode is clear)
CF set on error
AL = error code (see AH=00h)
Note: this command receives data using DMA
SeeAlso: AH=11h,AH=12h
Format of SCSI Command:
Offset Size Description
00h BYTE length of command
01h ??? command bytes
--------d-7814-------------------------------
INT 78 - TARGA.DEV - SEND SCSI COMMAND AND DATA (DMA)
AH = 14h
DS:SI -> command bytes
ES:BX -> data storage area
DX:CX = number of data bytes to transfer
Return: AH = SCSI status byte (if early return mode is clear)
CF clear if successful
AL = SCSI message byte (if early return mode is clear)
CF set on error
AL = error code (see AH=00h)
Note: this command sends data using DMA
SeeAlso: AH=12h,AH=13h
Format of SCSI Command:
Offset Size Description
00h BYTE length of command
01h ??? command bytes
--------d-7815-------------------------------
INT 78 - TARGA.DEV - FINISH DATA TRANSFER (DMA)
AH = 15h
Return: AH = SCSI status byte
CF clear if successful
AL = SCSI message byte
CF set on error
AL = error code (see AH=00h)
Note: if AH=06h was previously called to set the early return mode, this
function finishes a command AH=13h or AH=14h which returned before
the last DMA transfer was finished
SeeAlso: AH=06h,AH=13h,AH=14h
--------V-79---------------------------------
INT 79 - AVATAR.SYS - FAST GET KEYSTROKE
Return: CF set if no keystroke available
AX = FFFFh
CF clear if key pressed
AX = keystroke
Program: AVATAR.SYS is a CON driver by George Adam Stanislav which interprets
AVATAR command codes just as ANSI.SYS interprets ANSI commands
Note: if a keystroke is available, it is removed from the keyboard buffer
before being returned
SeeAlso: INT 29
--------E-79---------------------------------
INT 79 - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ1
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 09,INT 78"GO32",INT 7A"GO32"
--------d-79---------------------------------
INT 79 U - ADP-60 IDE adapter - ???
SeeAlso: INT 78"ADP-60"
--------E-79---------------------------------
INT 79 - DBOS DOS Extender
details not available
Desc: this interrupt is used by an MS Windows virtual device driver with
which the DBOS extender communicates when run inside a Windows
Enhanced Mode DOS box
SeeAlso: INT 78"DBOS"
--------A-790001-----------------------------
INT 79 R - AutoCAD Device Interface - DIGITIZER - INITIALIZE
AX = 0001h
BX = interface level (0001h)
Return: AX = status (0000h initialization failed, 0001h init successful)
BX = digitizer type
0000h relative pointing device (mouse, etc.)
0001h digitizing tablet
CX = digitizer dataflow type
0000h continuous
0001h pauses between packets
SeeAlso: AX=0002h,AX=0003h,INT 7A/AX=0001h"AutoCAD"
--------A-790002-----------------------------
INT 79 R - AutoCAD Device Interface - DIGITIZER - TERMINATE
AX = 0002h
SeeAlso: AX=0001h,AX=0003h
--------A-790003-----------------------------
INT 79 R - AutoCAD Device Interface - DIGITIZER - GET DIGITIZER STATUS
AX = 0003h
Return: AX = status
0000h nothing
0002h tracking point (no button pressed)
BX = X coordinate
CX = Y coordinate
0003h picked point (button 0,A,B,C,D pressed)
BX = X coordinate
CX = Y coordinate
0004h button pick
BX = button number
0005h button and coordinates
BX = button number
CX = X coordinate
DX = Y coordinate
SeeAlso: AX=0001h,AX=0002h
--------N-7A---------------------------------
INT 7A U - Topware Network Operating System - ???
AL = ???
???
Return: ???
SeeAlso: INT 21/AH=FFh"Topware",INT 2F/AX=FF00h
--------N-7A---------------------------------
INT 7A - X.PC Packet software interface
ES:BX -> parameter block
SeeAlso: INT 60/AX=01FFh
--------E-7A---------------------------------
INT 7A - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ2
Program: GO32.EXE is a DOS extender included as part of the 80386 port of the
GNU C/C++ compiler by DJ Delorie and distributed as DJGPP
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 0A,INT 79"GO32",INT 7B"GO32"
--------P-7A---------------------------------
INT 7A O - PRINDIR - API (moved to INT 7C)
SeeAlso: INT 7C"PRINDIR"
--------N-7A---------------------------------
INT 7A - Novell NetWare - LOW-LEVEL API - Notes
Note: this interrupt is used for IPX/SPX access in NetWare versions through
2.0a; in later versions, you should use INT 2F/AX=7A00h to get an
entry point even though INT 7A still exists. For both INT 7A and
the FAR entry point, BX contains the function number; IPX is
sometimes called internally with BX bit 15 set.
SeeAlso: INT 2F/AX=7A00h,INT 64"Novell",INT 7A/BX=0000h
--------N-7A----BX0000-----------------------
INT 7A - Novell NetWare - IPX Driver - OPEN SOCKET
BX = 0000h
AL = socket longevity
00h open until close or terminate
FFh open until close
DX = socket number (high byte in DL)
0000h dynamic allocation
else socket to open (see below)
Return: AL = return code
00h success
DX = socket number
FEh socket table full
FFh socket already open
Notes: TSRs which need to use sockets should set AL to FFh, non-resident
programs should normally use AL=00h
IPX can be configured to support up to 150 open sockets on a
workstation, and defaults to 20
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0001h,BX=0004h
Values for socket number:
0451h File Service (NetWare Core Protocol)
0452h Service Advertising Protocol
0453h Routing Information Packet
0455h NetBIOS Packet
0456h diagnostics
0457h server serial numbers (labeled "Copy Protection" by Lanalyzer)
4000h-7FFFh used for dynamic allocation
4444h Brightwork Development's SiteLock server
5555h Brightwork Development's SiteLock client (workstation)
8000h-FFFFh assigned by Novell
Note: SiteLock is an application metering product using IPX to communicate
between the application and the license server
--------N-7A----BX0001-----------------------
INT 7A - Novell NetWare - IPX Driver - CLOSE SOCKET
BX = 0001h
DX = socket number (high byte in DL)
Notes: also cancels events set by any Event Control Blocks for the socket
the program must close all open sockets before terminating
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0000h
--------N-7A----BX0002-----------------------
INT 7A - Novell NetWare - IPX Driver - GET LOCAL TARGET
BX = 0002h
ES:SI -> target internetwork address (see INT 7A/BX=000Bh)
ES:DI -> 6-byte buffer for local target
Return: AL = return code
00h success
CX = expected one-way transfer time (clock ticks) for a 576-byte
packet
ES:DI -> local target
FAh unsuccessful (no path to destination)
Notes: the internetwork address consists of a 4-byte network address followed
by a 6-byte node address. The local target is only a 6-byte node
address. If the target is in the same network, the local target is
just the node address of target; otherwise, the local target is the
node address of the bridge that leads to the target.
this function may be called from inside IPX and AES Event Service
Routines, but not from other interrupt handlers
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0009h
--------N-7A----BX0003-----------------------
INT 7A - Novell NetWare - IPX Driver - SEND PACKET
BX = 0003h
ES:SI -> Event Control Block (see below)
Notes: returns immediately; IPX attempts to send the packet in the background
this function is supported by Advanced NetWare 1.02+
this function is nearly identical to BX=000Fh, except that it always
copies the source address into the IPX header assumed to be at the
beginning of the first fragment
SeeAlso: BX=0004h,BX=000Fh,INT 21/AH=EEh"Novell"
Format of Event Control Block:
Offset Size Description
00h DWORD Link
04h DWORD -> Event Service Routine (00000000h if none)
08h BYTE in use flag (see below)
09h BYTE completion code (see below)
0Ah WORD (big-endian) socket number (see INT 7A/BX=0000h)
0Ch 4 BYTEs IPX workspace
10h 12 BYTEs driver workspace
1Ch 6 BYTEs immediate local node address
22h WORD fragment count
24h var fragment descriptors
Offset Size Description
00h DWORD -> fragment data
04h WORD size of fragment in bytes.
Notes: ESR is a far procedure that is called when the ECB has been handled.
On call, the in use flag is zero if the ECB has been handled,
non-zero otherwise. If the flag is zero, the completion code holds
the result of the event.
the first fragment should start with an IPX header
all fragments are concatenated and sent in one piece
node address FFh FFh FFh FFh FFh FFh broadcasts to all nodes
Format of AES-ECB:
Offset Size Description
00h DWORD Link
04h DWORD ESR address
08h BYTE in use flag (see below)
09h 5 BYTEs AES workspace
Values for ECB in use flag:
00h available
E0h AES temporary
F6h \ special IPX/SPX processing for v3.02+
F7h /
F8h IPX in critical section
F9h SPX listening
FAh processing
FBh holding
FCh AES waiting
FDh AES couting down delay time
FEh awaiting packet reception
FFh sending packet
Values for ECB completion code:
00h success
ECh remote terminated connection without acknowledging packet
EDh abnormal connection termination
EEh invalid connection ID
EFh SPX connection table full
F9h event should not be cancelled
FAh cannot establish connection with specified destination
FCh cancelled
FDh malformed packet
FEh packet undeliverable
FFh physical error
Event Service Routine called with:
AL = caller's identity (00h = AES, FFh = IPX)
ES:SI -> event control block
interrupts disabled
Format of IPX header:
Offset Size Description
00h WORD (big-endian) checksum
02h WORD (big-endian) length in bytes of total packet
04h BYTE transport control
05h BYTE packet type (see below)
06h 10 BYTEs destination internetwork address
10h WORD (big-endian) destination socket
12h 10 BYTEs source internetwork address
1Ch WORD (big-endian) source socket
Values for IPX packet type:
00h unknown packet type
01h routing information packet
02h echo packet
03h error packet
04h packet exchange packet (always use this one)
05h SPX packet
11h NetWare Core Protocol
14h Propagated Packet (for NetWare), NetBIOS name packet
15h-1Eh experimental protocols
Format of Service Advertising Protocol Service Query Packet:
Offset Size Description
00h 30 BYTEs IPX header
1Eh WORD (big-endian) query type
0001h general find service
0003h find nearest server
20h WORD (big-endian) server type (see INT 21/AH=E3h"NetWare")
Format of Service Advertising Protocol Server Identification Packet:
Offset Size Description
00h 30 BYTEs IPX header
1Eh WORD (big-endian) response type
0002h general service
0004h nearest service
20h 64N BYTEs server entries (1-7) (see below)
Format of SAP server entry:
Offset Size Description
00h WORD (big-endian) server type (see INT 21/AH=E3h"NetWare")
02h 48 BYTEs ASCIZ server name
32h 2 WORDs (big-endian) network number
34h 3 WORDs (big-endian) node number
3Ch WORD (big-endian) socket number
3Eh WORD (big-endian) number of hops between caller and server
Format of Routing Information packet:
Offset Size Description
00h 30 BYTEs IPX header
1Eh WORD operation (0001h request, 0002h response)
20h 8N BYTEs network entries (1-50) (see below)
Format of RIP network entry:
Offset Size Description
00h DWORD network number (FFFFFFFFh = general request)
04h WORD (response) number of hops
06h WORD (response) number of clock ticks to reach destination
--------N-7A----BX0004-----------------------
INT 7A - Novell NetWare - IPX Driver - LISTEN FOR PACKET
BX = 0004h
ES:SI -> Event Control Block (see BX=0003h)
Return: AL = status
00h successful
FFh no listening socket for packet
Desc: this function provides IPX with an ECB for receiving an IPX packet, but
does not wait for a packet to arrive
Notes: the application must open a socket and initialize the ECB's ESR
address, socket number, fragment count, and fragment descriptor
fields before invoking this function
there is no limit on the number of ECBs which may simultaneously be
listening on a socket
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0000h,BX=0003h
--------N-7A----BX0005-----------------------
INT 7A - Novell NetWare - IPX Driver - SCHEDULE IPX EVENT
BX = 0005h
AX = delay time in clock ticks
ES:SI -> Event Control Block (see BX=0003h)
Note: this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0006h,BX=0007h,BX=0008h
--------N-7A----BX0006-----------------------
INT 7A - Novell NetWare - IPX Driver - CANCEL EVENT
BX = 0006h
ES:SI -> Event Control Block (see BX=0003h)
Return: AL = return code
00h success
F9h event in use
FCh event cancelled
FFh unsuccessful, event not in use, or unrecognized ECB flag
Notes: cannot cancel packets which the node's driver has already sent
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0005h
--------N-7A----BX0007-----------------------
INT 7A - Novell NetWare - IPX Driver - SCHEDULE SPECIAL EVENT
BX = 0007h
AX = delay time
ES:SI -> Event Control Block (see BX=0003h)
Note: this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0006h
--------N-7A----BX0008-----------------------
INT 7A - Novell NetWare - IPX Driver - GET INTERVAL MARKER
BX = 0008h
Return: AX = interval marker in clock ticks
Notes: may be used to measure the time elapsed between two events, up to one
hour
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0005h
--------N-7A----BX0009-----------------------
INT 7A - Novell NetWare - IPX Driver - GET INTERNETWORK ADDRESS
BX = 0009h
ES:SI -> buffer for own internetwork address (see below)
Return: ES:SI buffer filled
SI destroyed
Note: this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0002h,BX=000Bh
Format of internetwork address:
Offset Size Description
00h 4 BYTEs (big-endian) network number
04h 6 BYTEs (big-endian) node number within network
--------N-7A----BX000A-----------------------
INT 7A - Novell NetWare - IPX Driver - RELINQUISH CONTROL
BX = 000Ah
Desc: this call indicates that the application is idle and permits the IPX
driver to do some work
Note: this function is supported by Advanced NetWare 1.02+
SeeAlso: INT 15/AX=1000h,INT 21/AH=89h,INT 2F/AX=1680h
--------N-7A----BX000B-----------------------
INT 7A - Novell NetWare - IPX Driver - DISCONNECT FROM TARGET
BX = 000Bh
ES:SI -> internetwork address (see below)
Notes: this function permits the network software on the remote machine to
remove any virtual connection with the calling machine
only use in point-to-point networks
should never be called from within an Event Service Routine
this function is supported by Advanced NetWare 1.02+
SeeAlso: BX=0002h,BX=0009h
Format of internetwork address:
Offset Size Description
00h 4 BYTEs (big-endian) destination network
04h 6 BYTEs (big-endian) destination node
0Ah 2 BYTEs (big-endian) destination socket
--------N-7A----BX000C-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - INITIALIZE NETWORK ADDRESS
BX = 000Ch
CX:DX = global network address (see INT 7A/BX=0002h)
ES:DI -> "OSINCRITICALSECTION" flag
DS:SI -> current mode for socket
Note: the address cannot be changed once it has been initialized
--------N-7A----BX000D-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - IPX GET PACKET SIZE
BX = 000Dh
Return: AX = maximum packet size
CX = retry count
SeeAlso: BX=001Ah
--------N-7A----BX000E-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - TERMINATE SOCKETS
BX = 000Eh
Return: nothing
Note: this function terminates all sockets opened with the current mode; this
may be intended for future enhancements as the socket mode never
changes in v2.15
--------N-7A----BX000F-----------------------
INT 7A U - Novell NetWare - IPX Driver - INTERNAL - SEND PACKET
BX = 000Fh
ES:SI -> Event Control Block (see BX=0003h)
Note: nearly identical to function 0003h, but does not copy address into
the first fragment
SeeAlso: BX=0003h
--------N-7A----BX0010-----------------------
INT 7A - Novell NetWare - SPX Driver - INSTALLATION CHECK
BX = 0010h
AL = 00h
Return: AL = FFh if SPX loaded
BH = SPX major version
BL = SPX minor version
CX = maximum SPX connections
DX = SPX connections available
Note: this function is supported by Advanced NetWare 2.1+
this interrupt is used for IPX/SPX access in NetWare versions through
2.0a; in later versions, you should use INT 2F/AX=7A00h to get an
entry point even though INT 7A still exists. For both INT 7A and
the FAR entry point, BX contains the function number; IPX is
sometimes called internally with BX bit 15 set.
SeeAlso: BX=0015h
--------N-7A----BX0011-----------------------
INT 7A - Novell NetWare - SPX Driver - ESTABLISH SPX CONNECTION
BX = 0011h
AL = retry count
AH = watchdog flag
ES:SI -> Event Control Block (see BX=0003h)
Return: AL = status
00h attempting to contact destination socket
EFh local connection table full
FDh buffer size not 42 or fragment count not 1
FFh sending socket not open
DX = assigned connection ID number
Desc: attempt to establish a connection with a listening socket
Notes: there should always be at least two SPX ECB's listening to a socket, so
that NetWare can perform its internal packet exchanges
the first fragment should start with a SPX header. Fill in all
destination addresses.
this function is supported by Advanced NetWare 2.1+
SeeAlso: BX=0000h,BX=0012h,BX=0013h,BX=0014h,BX=0015h
Format of SPX header:
Offset Size Description
00h WORD (big-endian) checksum
02h WORD (big-endian) length in bytes of total packet
04h BYTE transport control
05h BYTE packet type (see INT 7A/BX=0003h)
06h 10 BYTEs destination internet address
10h WORD (big-endian) destination socket
12h 10 BYTEs source internet address
1Ch WORD (big-endian) source socket
1Eh BYTE connection control (see below)
1Fh BYTE datastream type
FEh terminate connection request packet
FFh terminate connection acknowledgement packet
other user-defined, ignored by SPX
20h WORD (big-endian) source connection ID
22h WORD (big-endian) destination connection ID
24h WORD (big-endian) sequence number
26h WORD (big-endian) acknowledge number
28h WORD (big-endian) allocation number
Bitfield for connection control:
bits 3-0 unused???
bit 4 end of message
bit 5 reserved
bit 6 acknowledgement required
bit 7 system packet
--------N-7A----BX0012-----------------------
INT 7A - Novell NetWare - SPX Driver - LISTEN FOR SPX CONNECTION
BX = 0012h
AH = watchdog flag
00h disabled
01h enabled
AL = retry count (00h = default)
ES:SI -> Event Control Block (see BX=0003h)
Notes: there should always be at least two SPX ECB's listening to a socket, so
that NetWare can perform its internal packet exchanges
this function is supported by Advanced NetWare 2.1+
SeeAlso: BX=0011h,BX=0013h,BX=0014h
--------N-7A----BX0013-----------------------
INT 7A - Novell NetWare - SPX Driver - TERMINATE SPX CONNECTION
BX = 0013h
DX = connection ID to terminate
ES:SI -> Event Control Block (see BX=0003h)
Note: this function is supported by Advanced NetWare 2.1+
SeeAlso: BX=0011h,BX=0012h,BX=0014h
--------N-7A----BX0014-----------------------
INT 7A - Novell NetWare - SPX Driver - ABORT SPX CONNECTION
BX = 0014h
DX = connection ID to terminate
Notes: this function is supported by Advanced NetWare 2.1+
this function does not tell the other side that the connection has been
terminated
also aborts any outstanding Establish Connection, Terminate Connection,
and Send Sequenced Packet commands
SeeAlso: BX=0011h,BX=0013h
--------N-7A----BX0015-----------------------
INT 7A - Novell NetWare - SPX Driver - GET SPX CONNECTION STATUS
BX = 0015h
DX = connection ID
ES:SI -> status buffer (see below)
Return: AL = return code
00h connection still valid
ES:SI -> status buffer filled
EEh no such connection
Note: this function is supported by Advanced NetWare 2.1+
SeeAlso: BX=0010h,BX=0011h
Format of status buffer:
Offset Size Description
00h BYTE connection state
01h waiting to establish connection
02h starting (attempting to create connection)
03h connection established
04h terminating
01h BYTE watchdog flag
bit 0: used internally by SPX
bit 1: SPX watchdog is monitoring connection
bits 2-7 used internally by SPX
02h WORD (big-endian) source connection ID
04h WORD (big-endian) destination connection ID
06h WORD (big-endian) sequence number of next packet sent
08h WORD (big-endian) acknowledge number, expected sequence number of
next received packet
0Ah WORD (big-endian) maximum sequence number remote SPX may send
without ACK from local SPX
0Ch WORD (big-endian) remote acknowledge number, next sequence number
remote SPX expects to receive
0Eh WORD (big-endian) remote allocation number, maximum sequence number
local SPX may send
10h WORD (big-endian) connection socket
12h 6 BYTEs immediate node address--bridge on local network to destination
18h 10 BYTEs destination internetwork address (see INT 7A/BX=000Bh)
22h WORD (big-endian) retransmit count
24h WORD (big-endian) estimated roundtrip delay
26h WORD (big-endian) retransmitted packets
28h WORD (big-endian) suppressed packets
2Ah 12 BYTEs ??? (v2.15)
--------N-7A----BX0016-----------------------
INT 7A - Novell NetWare - SPX Driver - SEND SPX PACKET
BX = 0016h
DX = connection ID
ES:SI -> Event Control Block (see BX=0003h)
Notes: this function is supported by Advanced NetWare 2.1+
CX may need to be 0001h ???
SeeAlso: BX=0011h,BX=0017h
--------N-7A----BX0017-----------------------
INT 7A - Novell NetWare - SPX Driver - LISTEN FOR SPX PACKET
BX = 0017h
DX = connection ID (unused in v2.15)
ES:SI -> Event Control Block (see BX=0003h)
Notes: this function is supported by Advanced NetWare 2.1+
CX may need to be 0001h ???
SeeAlso: BX=0011h,BX=0016h
--------N-7A----BX0018-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - ADD DIAGNOSTIC ELEMENT
BX = 0018h
ES:SI -> diagnostic element (see below) to be added to Diagnostic Queue
Note: this function is supported on file servers only under v2.15; v3.02 also
supports it on workstations
SeeAlso: BX=0019h
Format of diagnostic element:
Offset Size Description
00h DWORD pointer to next diagnostic element
04h DWORD pointer to function for ???
08h DWORD pointer to function for ???
--------N-7A----BX0019-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - CANCEL DIAGNOSTIC ELEMENT
BX = 0019h
ES:SI -> diagnostic element (see BX=0018h) to be removed
Note: this function is supported on file servers only under v2.15; v3.02 also
supports it on workstations
SeeAlso: BX=0018h
--------N-7A----BX001A-----------------------
INT 7A U - Novell NetWare - IPX Driver - internal - GET DRIVER PACKT SIZE LIMIT
BX = 001Ah
Return: AX = packet size with preamble
CX = IPX retry count
Note: this function is supported on file servers only under v2.15; v3.02 also
supports it on workstations
SeeAlso: BX=000Dh
--------N-7A----BX001B-----------------------
INT 7A U - Novell NetWare - IPX Driver - INTERNAL
BX = 001Bh
???
Return: ???
Note: this function is supported on file servers only under v2.15; v3.02 also
supports it on workstations
--------A-7A0001-----------------------------
INT 7A R - AutoCAD Device Interface - DISPLAY - INITIALIZE (INIT1)
AX = 0001h
BX = configuration
CX = interface level (0001h)
Return: AX = status
0000h initialization failed
0001h pre-v4.0 driver initialized successfully
0003h post-v3.1 driver initialized successfully (driver truncates
excessivly long packets)
BX = width of graphics area in pixels, or 0000h if using packet
communication
DX:CX -> packet-mode entry point
SeeAlso: AX=0001h,AX=0200h,AX=07D0h,INT 61/AX=0007h"OPTIMA",INT 78"AutoCAD"
SeeAlso: INT 79/AX=0001h,INT 7B/AX=8001h"AutoCAD",INT 7C"AutoShade"
Call packet-mode entry point with:
STACK: DWORD pointer to request packet
WORD length of packet
Format of request packet:
Offset Size Description
00h WORD function number (00h-45h for Compaq VGADI41.EXE)
--------A-7A0200BX0000-----------------------
INT 7A R - AutoCAD Device Interface - RENDERING DEVICE - INITIALIZE (RDLINKUP)
AX = 0200h
BX = 0000h
CX = interface level (0001h)
Return: BX = 0000h (driver uses packet communication)
DX:CX -> packet-mode entry point (see AX=0001h"AutoCAD")
SeeAlso: AX=0001h"AutoCAD",INT 79/AX=0001h,INT 7B/AX=8001h"AutoCAD"
--------I-7A04-------------------------------
INT 7A - IBM 3270 Workstation Program API - CREATE A QUEUE
AH = 04h
???
Return: ???
SeeAlso: AH=06h
--------I-7A06-------------------------------
INT 7A - IBM 3270 Workstation Program API - DELETE A QUEUE
AH = 06h
???
Return: ???
SeeAlso: AH=04h
----------7A07D0-----------------------------
INT 7A R - AutoCAD Device Interface - Compaq VGADI41.EXE - GET ENTRY POINT
AX = 07D0h
Return: AX = ??? (0003h)
BX = 0000h
DX:CX -> ADI entry point (see AX=0001h)
SeeAlso: AX=0001h
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - SESSION SERVICES
AH = 09h
BX = 8020h (synchronous request)
CX = 0000h
DX = ID of session manager (SESSMGR)
AL = service
01h get session ID
02h get session info
04h dettach from session
05h attach to session
06h get list of windows available
07h get environment of window
08h get 'PIF' (program information file) info
0Ah get base window ID
0Bh get cursor info
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - KEYBOARD SERVICES
AH = 09h
BX = 8020h (synchronous request)
CX = 0000h
DX = ID of keyboard manager
AL = service
01h connect to keyboard
02h disconnect from keyboard
03h read from keyboard
04h send keystroke to session
05h disable input
06h enable input
07h update status code
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - WINDOW SERVICES
AH = 09h
BX = 8020h (synchronous request)
CX = 00FFh
DX = ID of window service controller (WSCTRL)
AL = service
01h connect to WS control
02h disconnect from WS control
03h add a window
04h change window's position on screen
05h change window's size
06h change window's color
07h change window's position in the presentation space
08h hide/unhide toggle
09h enlarge/reduce toggle
0Ah change screen background color
0Bh get window's position on screen
0Ch get window's size
0Dh get window's color
0Eh get window's position in the presentation space
0Fh determine whether hidden
10h determine whether enlarged
11h get background color
12h get window names
13h delete all windows from profile
14h pick active window
15h redraw screen
16h redraw window
17h delete a window from profile
18h get active window
19h get active screen
1Ah get window data
1Bh change window data
1Ch select active screen
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - PRESENTATION SPACE SERVICES
AH = 09h
BX = 8020h
CX = 00FFh
DX = ID of PCPSM
AL = service
01h define presentation space
02h delete presentation space
03h display presentation space
04h position cursor in presentation space
05h change default presentation space
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - 3270 EMULATION
AH = 09h
BX = 8020h
CX = 00FFh
DX = ID of 3270EML
AL = service
01h connect
02h disconnect
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - OPERATOR INFORMATION AREA
AH = 09h
BX = 8020h
CX = 00FFh
DX = ID of OIAM
AL = service
01h read Operator Information Area
02h read OIA subset
ES:DI -> control block
Return: ???
Note: the OIA is the 25th line on the Host session
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - TRANSLATE DATA
AH = 09h
BX = 8020h
CX = 00FFh
DX = ID of XLATE
AL = service
01h translate from host characters to ASCII and vice versa
(determined by control block byte 11)
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - COPY SERVICE
AH = 09h
BX = 8020h
CX = 00FFh
DX = ID of copy service
AL = service
01h copy string from one presentation space to another
02h copy block from one presentation space to another
03h connect to PC session for copy
04h disconnect PC session from copy
ES:DI -> control block
Return: ???
--------I-7A09--BX8020-----------------------
INT 7A - IBM 3270 Workstation Program API - Multi-DOS
AH = 09h
BX = 8020h
CX = 00FFh
ES:DI -> control block
DX = ID of INDJQRY
get environment size
= ID of INDJASY
request DOS functions from workstation
= ID of MEMORY
AL = function
01h allocate memory
02h deallocate memory
03h modify allocated size
Return: ???
--------I-7A09-------------------------------
INT 7A - IBM 3270 Workstation Program API - HOST SERVICES
AH = 09h
BX = request type (4000h async, 8028h synchronous)
CX = 0000h
DX = ID of MFIC
AL = service
01h connect to host
02h disconnect from host
03h read DFT structured data from host
04h write DFT structured data to host
05h create a host buffer
ES:DI -> control block
--------I-7A13-------------------------------
INT 7A - IBM 3270 Workstation Program API - GET DATA FROM A QUEUE
AH = 13h
???
Return: ???
----------7A7A-------------------------------
INT 7A - Canon IX-30F Image Scanner SI3.SYS - INTERFACE
AH = 7Ah
???
Return: AX = 0000h success
000Eh undefined function code
Note: this interface is normally on INT 7A but can be changed via device
driver command line arguments
--------I-7A81-------------------------------
INT 7A - IBM 3270 Workstation Program API - RESOLVE A GATE NAME
AH = 81h
ES:DI -> 8-char blank-padded gate name
"SESSMGR ", "KEYBOARD", "WSCTRL ", "MFIC ", "PCPSM ",
"3270EML ", "COPY ", "XLATE ", "OIAM ", "MEMORY ",
"INDJQRY ", or "INDJASY "
Return: DX = gate ID
--------I-7A83-------------------------------
INT 7A - IBM 3270 Workstation Program API - GET COMPLETION RESULTS
AH = 83h
???
Return: ???
--------I-7AFDCB-----------------------------
INT 7A - IBM Personal Communications/3270 - INSTALLATION CHECK
AX = FDCBh
Return: DX:AX -> PCS/3270 signature block if loaded (see below)
Format of signature block:
Offset Size Description
04h WORD PCS/3270 signature (5741h)
06h WORD version (0501h = PCS/3270 v1.0)
--------I-7AFE01-----------------------------
INT 7A - IBM PC3270 EMUL PROG v3 - INTERNAL SEND/RECEIVE FUNCTION
AX = FE01h
???
Return: ???
SeeAlso: AX=FE02h
--------I-7AFE02-----------------------------
INT 7A - IBM PC3270 EMUL PROG v3 - INTERNAL SEND/RECEIVE FUNCTION
AX = FE02h
???
Return: ???
SeeAlso: AX=FE01h
--------I-7AFF01-----------------------------
INT 7A - IBM PC3270 EMUL PROG v3 - INTERNAL API INITIALIZATION
AX = FF01h
ES:DI -> API function handler routine
Return: CX = 1200h
SeeAlso: AX=FF02h,AX=FF03h
--------I-7AFF02-----------------------------
INT 7A - IBM PC3270 EMUL PROG v3 - INTERNAL API TERMINATION
AX = FF02h
Return: CX = 1200h
SeeAlso: AX=FF01h
--------I-7AFF03-----------------------------
INT 7A - IBM PC3270 EMUL PROG v3 - INTERNAL API INITIALIZATION
AX = FF03h
ES:DI -> send/receive function handler routine
Return: CX = 1200h
SeeAlso: AX=FF01h
--------I-7AFF04-----------------------------
INT 7A U - IBM PC3270 EMUL PROG v3 - INTERNAL ???
AX = FF04h
ES:DI -> ???
Return: CX = 1200h
--------f-7B---------------------------------
INT 7B - Btrieve API (single user)
DS:DX -> 38-byte parameter record (see below)
Return: return code field set
Note: Btrieve sets low byte of vector to 33h; this serves as the installation
check
SeeAlso: INT 2F/AX=AB01h,INT 7F/AX=0200h
Format of Btrieve parameter record:
Offset Size Description
00h DWORD pointer to data buffer
04h WORD data buffer length
06h DWORD pointer to 90-byte record containing positioning info
(should be same for all calls for same file)
0Ah DWORD pointer to 38-byte FCB info buffer
(should be same for all calls for same file)
0Eh WORD function code (see below)
10h DWORD pointer to file name/key buffer
14h BYTE key length
15h BYTE key number
16h DWORD pointer to status code (see below)
1Ah WORD interface code (version specific)
6176h version 5.10
Values for function code:
00h open
01h close
02h insert
03h update
04h delete
05h get_equal
06h get_next
07h get_prev
08h get_greater
09h get_gr_eql
0Ah get_less
0Bh get_less_eq
0Ch get_first
0Dh get_last
0Eh create
0Fh stat
10h extend
11h set_dir: set directory information
12h get_dir: get directory information
13h begin_trans
14h end_trans
15h abort_trans
16h get_pos: get record position number
17h get_direct: get data by sending record position
18h step_next
19h stop
1Ah version
1Bh unlock
1Ch reset
1Dh set owner
1Eh clear owner
1Fh create supplemental index
20h drop supplemental index
21h step first
22h step last
23h step previous
24h get next extended: get multiple records using a filter
25h get previous extended: get multiple records using a filter
26h step next extended: get multiple records using a filter
27h step previous extended: get multiple records using a filter
28h insert extended: insert one or more records
31h ???
add 50 (32h) to any "get" operation to just return the key data
add 100 (64h) for a single-record wait lock (automatically released on next
get)
add 200 (C8h) for a single-record nowait lock (nowait lock returns error 54h
or 55h if record already locked)
add 300 (12Ch) for a multiple-record wait lock (not released until unlock
called)
add 400 (190h) for a multiple-record nowait lock (nowait lock returns error
54h or 55h if record already locked)
Values for status code:
00h successful
01h invalid operation
02h I/O error
03h file not open
04h key value not found
05h duplicate key value
06h invalid key number
07h different key number
08h invalid positioning
09h end of file
0Ah modifiable key value error
0Bh invalid file name
0Ch file not found
0Dh extended file error
0Eh pre-image open error
0Fh pre-image I/O error
10h expansion error
11h close error
12h disk full
13h unrecoverable error
14h record manager inactive
15h key buffer too short
16h data buffer length overrun
17h position block length
18h page size error
19h create I/O error
1Ah number of keys
1Bh invalid key position
1Ch invalid record length
1Dh invalid key length
1Eh not a Btrieve file
1Fh file already extended
20h extended I/O error
22h invalid extension name
23h directory error
24h transaction error
25h transaction is active
26h transaction control file I/O error
27h end/abort transaction error
28h transaction max files
29h operation not allowed
2Ah incomplete accelerated access
2Bh invalid record address
2Ch null key path
2Dh inconsistent key flags
2Eh access to file denied
2Fh maximum open files
30h invalid alternate sequence definition
31h key type error
32h owner already set
33h invalid owner
34h error writing cache
35h invalid interface
36h variable page error
37h autoincrement error
38h incomplete index
39h expanded memory error
3Ah compression buffer too short
3Bh file already exists
3Ch reject count reached
3Dh work space too small
3Eh incorrect descriptor
3Fh invalid extended insert
40h filter limit reached
41h incorrect field offset
4Ah automatic transaction abort
4Eh deadlock detected
50h conflict
51h lock error
52h lost position
53h read outside transaction
54h record in use
55h file in use
56h file table full
57h handle table full
58h incompatible open mode
5Ah redirected device table full
5Bh server error
5Ch transaction table full
5Dh incompatible lock type
5Eh permission error
5Fh session no longer valid
60h communications environment error
61h data message too small
62h internal transaction error
--------I-7B---------------------------------
INT 7B - Eicon Access API (3270/5250 gateways)
SeeAlso: INT 5C"NetBIOS"
--------E-7B---------------------------------
INT 7B - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ3
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 0B,INT 10/AH=FFh"GO32",INT 7A"GO32",INT 7C"GO32"
--------A-7B---------------------------------
INT 7B CR - AutoCAD Device Interface - PRINTER/PLOTTER - SEND PLOTTING DATA
AX = data length (0000h-7FFFh)
CX:BX -> data to be plotted
DX = vertical position of line on page
Return: nothing
Notes: This interrupt is called by AutoCAD to perform its output
A data length of 0000h indicates that a blank line is to be output
SeeAlso: AX=8001h,AX=8002h,INT 78"AutoCAD",INT 7A/AX=0001h"AutoCAD"
--------A-7B8001-----------------------------
INT 7B R - AutoCAD Device Interface - PRINTER/PLOTTER - BEGIN PLOT
AX = 8001h
BX = file level
0000h binary file
0001h CAD/camera image file
0002h installed ADI driver
CX = horizontal size in pixels
DX = vertical size in pixels
Return: AX = status (0000h initialization failed, 0001h init successful)
BX = allowed output format
0000h monochrome
0001h color (4 bits per pixel)
SeeAlso: AX=8002h,AX=8003h,INT 7B"AutoCAD",INT 7C"AutoShade"
--------A-7B8002-----------------------------
INT 7B R - AutoCAD Device Interface - PRINTER/PLOTTER - END PLOT
AX = 8002h
SeeAlso: AX=8001h,AX=8003h
--------A-7B8003-----------------------------
INT 7B R - AutoCAD Device Interface - PRINTER/PLOTTER - ABORT PLOT
AX = 8003h
SeeAlso: AX=8001h,AX=8002h
--------r-7C---------------------------------
INT 7C U - IBM REXX88PC command language
???
--------E-7C---------------------------------
INT 7C - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ4
Program: GO32.EXE is a DOS extender included as part of the 80386 port of the
GNU C/C++ compiler by DJ Delorie and distributed as DJGPP
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 0C,INT 7B"GO32",INT 7D"GO32"
--------P-7C---------------------------------
INT 7C - PRINDIR v8.02+ - API
AH = function
00h set output to Invisible mode
01h set output to LPT1
02h set output to LPT2
03h set output to LPT3
04h set output to COM1
05h set output to COM2
06h set output to COM3
07h set output to COM4
08h set output to screen
09h set output to file
0Ah change file path
ES:DI -> new path
CX = length of path (max 41, but not range-checked)
0Bh change file name
ES:DI -> new filename
CX = length of new name (max 41, but not range-checked)
0Ch set redirected device
(01h = LPT1 ... 03h = LPT3, 04h = COM1 ... 07h = COM4)
0Dh force buffer dump
0Eh set display color
AL = new color attribute (see INT 10/AH=08h)
0Fh set popup hotkey
AL = hotkey scancode
10h toggle byte display
AL = new state (00h off, 01h on)
11h change buffer flush delay
AL = timer ticks before flush
Return: AX = status
0000h successful
0001h invalid function or nothing in buffer to be dumped
(documented as "nonzero = error")
Program: PRINDIR is a shareware printer-redirection program by J.M. Allen
Creations
Notes: the installation check consists of testing for the ASCIZ signature
"PRINDIR N.NN" (where N.NN is the version number) two bytes beyond
the start of the interrupt handler
prior versions of PRINDIR used INT 7A instead of INT 7C
SeeAlso: INT 7A"PRINDIR"
Index: hotkeys;PRINDIR
--------A-7C---------------------------------
INT 7C - AutoShade v2 - RENDERING HARDCOPY DRIVER
Note: this is the default interrupt vector for rendering hardcopy drivers
instead of INT 7A used by AutoCAD drivers
SeeAlso: INT 7A/AX=0001h"AutoCAD"
--------N-7C---------------------------------
INT 7C - SK-UPPS/SK-PASSPORT Data Link Interface (DLI) API
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of it Data Link Interface, allowing the
use of any of several network transport layers; this product is
called SK-PASSPORT in the USA.
Notes: The installation check consists of testing for the ASCII signature
string "UPPS_DLI" immediately preceding the interrupt handler.
To find the service interrupt being used by the driver, an application
should scan through the interrupt table until it finds an interrupt
vector with the "UPPS_DLI" string.
There may be more than one DLI loaded, each having its own service
interrupt.
SeeAlso: AX=0000h,AX=0002h,AX=000Fh
Index: installation check;SK-UPPS
--------N-7C0000-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET DRIVER VERSION
AX = 0000h
Return: AH = major DLI version
AL = minor DLI version
DX = OEM signature (see below)
CL = DLI 2.8+ topology: 1=Ethernet, 2=FDDI, 3=Token-Ring
SeeAlso: AX=0002h,AX=000Bh,AX=000Dh,AX=000Eh
OEM signatures (defined by SK):
0001h experimental
3343h 3COM
4942h IBM
4943h Intellicom
494Eh Intel
4B4Fh Kodiak
4D41h Madge
4E45h Novell
4F43h Olicom
5349h Siemens
534Bh Schneider & Koch (SysKonnect)
5744h Western Digital
--------N-7C0001-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DOWN DRIVER
AX = 0001h
Return: AX = completion code (see below)
Note: the DLI will refuse to unload if there are any protocols
(see AX=0007h) or clients (see AX=0010h) active.
Index: uninstall;SK-UPPS Data Link Interface
Completion codes:
0000h SUCCESS
0005h INVALID_MULTICAST
0006h BUFFER_TOO_SMALL
0007h NO_BUFFERS_LEFT
0008h NO_RESOURCES_LEFT
000Bh ILLEGAL_PROTOCOL_ID
000Ch PROTOCOL_IN_USE
000Dh NO_MULTICAST_ADDRESS
000Fh PROTOCOLS_ACTIVE
0010h CLIENTS_ACTIVE
001Bh INVALID_MODE
001Ch MODE_NOT_SUPPORTED
FFFFh UNKNOWN_SERVICE
--------N-7C0002-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET DRIVER STATUS
AX = 0002h
ES:DI -> Status Information Block (SIB) (see AX=000Eh, description of
Driver Information Block)
Return: AX = completion code (see AX=0001h)
Note: GET DRIVER INFO (AX=000Eh) should be used instead.
SeeAlso: AX=0000h,AX=000Bh,AX=000Dh,AX=000Eh
--------N-7C0003-----------------------------
INT 7C - SK-UPPS Data Link Interface API - CHANGE DRIVER ADDRESS
AX = 0003h
ES:DI -> new node address (6 bytes)
Return: AX = completion code (see AX=0001h)
Note: the DLI will refuse to change the address if any protocols
(see AX=0007h) are active
SeeAlso: AX=0001h,AX=000Eh
--------N-7C0004-----------------------------
INT 7C - SK-UPPS Data Link Interface API - REQUEST BUFFER
AX = 0004h
DX = protocol ID (see AX=0007h)
Return: AX = completion code (see also AX=0001h)
0000h successful
ES:BX -> Memory Buffer (Mbuf) (see below)
Note: if the DLI has no free Mbufs, it will set an internal flag for the
protocol and later call the protocol's Event Upcall with
EV_BUFFER_AVAILABLE (see AX=0007h) as soon as an Mbuf becomes
available. There will only be one "buffer available" Upcall, even
if this function has been called several times before.
SeeAlso: AX=0005h,AX=0006h,AX=0012h,AX=0013h
Format of Memory Buffer (Mbuf):
Offset Size Description
00h DWORD -> NEXT Mbuf (linked list)
04h WORD OFFSET of actual data within DATA area
06h 2 BYTEs reserved (currently unused)
08h WORD LENGTH of actual data found in DATA area starting at OFFSET
0Ah 2 BYTEs reserved (currently unused)
0Ch DWORD -> DATA area (size can be obtained via AX=000Eh call)
10h WORD PROTOCOL ID of protocol currently "owning" the Mbuf
12h BYTE IN USE flag; nonzero if Mbuf still in use by DLI (see AX=0006h)
13h BYTE RECEIVE STATUS (bit 0-7 only; see AX=0007h - Receive Upcall)
--------N-7C0005-----------------------------
INT 7C - SK-UPPS Data Link Interface API - RELEASE BUFFER
AX = 0005h
ES:BX -> Mbuf (see AX=0004h)
Return: nothing
SeeAlso: AX=0004h
--------N-7C0006-----------------------------
INT 7C - SK-UPPS Data Link Interface API - TRANSMIT FRAME
AX = 0006h
ES:BX -> Mbuf (see AX=0004h)
Return: nothing
Notes: The DLI will send LENGTH bytes found in the Mbuf's DATA area starting
at OFFSET. A complete and valid frame must be stored there. The DLI
will only copy the current node address (see AX=0003h) to the
source node field of the frame's MAC header.
On Ethernet, the DLI will always send a minimum of 60 bytes, regardless
of the value found in the LENGTH field.
This function returns immediately; the DLI will call the protocol's
Transmit Upcall (see AX=0007h) when the frame has been sent.
The Mbuf's IN USE field will be non-zero until the DLI calls the
Transmit Upcall.
SeeAlso: AX=0002h,AX=0004h,AX=0013h
Transmit Upcall called with:
ES:BX -> Mbuf (NEXT field destroyed)
interrupts disabled
Note: On FDDI the bytes of the source and destination node fields in the MAC
header have been bit-swapped to physical address format.
--------N-7C0007-----------------------------
INT 7C - SK-UPPS Data Link Interface API - REGISTER PROTOCOL
AX = 0007h
ES:BX -> Protocol Control Block (see below)
Return: AX = completion code (see AX=0001h)
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of its Data Link Interface, allowing the
use of any of several network transport layers
SeeAlso: AX=0008h,AX=000Bh
Format of Protocol Control Block (PCB):
Offset Size Description
00h WORD protocol type (high-low)
02h WORD protocol mode (see below)
04h DWORD -> Receive Upcall routine
08h DWORD -> Transmit Upcall routine
0Ch DWORD -> Event Upcall routine
10h DWORD -> ASCIZ protocol name (zero if none)
14h WORD protocol ID will be returned here (always non-zero)
Bitfields for protocol mode:
bit 0 promiscuous mode; protocol receives all frames regardless of their
destination (PROTOCOL TYPE must be FFFFh)
bit 1 if set, protocol's Event Upcall will be called on entry and exit of the
DLI's Interrupt Service Routine (see event codes below)
bit 2 DLI 2.2+ hook mode; protocol receives all directed frames destined for
this station (PROTOCOL TYPE must be FFFFh)
bit 3 DLI 2.3+ receive error frames (only valid in promiscuous mode (bit 0))
bit 4-5 DLI 2.5+ frame type:
00 Ethernet II; specify type code in PROTOCOL TYPE field (high-low)
01 IEEE 802.2; specify Service Access Point (SAP) in MSB
(offset 0) of PROCOTOL TYPE field; LSB must be zero
10 IEEE 802.2 with SNAP header; specify type code in PROTOCOL TYPE
field (high-low)
11 reserved (currently unused)
bit 6 DLI 2.5+ if set, protocol's Event Upcall will be called with event code
EV_BUFFER_WANTED, when DLI runs out of Mbufs
bit 7 DLI 2.7+ chain mode; if set, client allows the specified frame type to
be shared with other clients
bit 8 DLI 2.8+ receive non-LLC frames rather than LLC frames
bit 9 DLI 2.8+ receive all multicast frames (see also AX=0009h)
bit 10-15 reserved (currently unused; must be zero)
Notes: If PROTOCOL TYPE is FFFFh and neither the "promiscuous" nor the "hook"
mode bit is set, the protocol receives all frames that did not match
any registered frame type (demultiplexor mode).
Protocols using "promiscuous", "hook" or "chain" mode should always
return from the Receive Upcall with the received Mbuf in ES:BX and the
Carry Flag set. The DLI will then pass the Mbuf to the FEED BACK
BUFFER function (see AX=000Fh).
Some DLIs do not support all or even any of the "promiscuous",
"receive non-LLC" and "receive all multicasts" mode bits.
Receive Upcall called with:
ES:BX -> Mbuf
AX = receive status (see below; also stored in Mbuf's RECEIVE STATUS field)
interrupts disabled
Bitfields for receive status (reserved bits currently unused and always zero):
bit 0-2 reserved
bit 3 frame check sequence (FCS) error
bit 4 overflow (frame too long)
bit 5 framing error
bit 6 reserved
bit 7 non-LLC frame (see bit 8 of PCB's protocol mode field)
bit 8-15 reserved
Notes: The protocol's Receive Upcall routine will be called whenever a frame
matching the specified frame type is received. A received frame is
passed to the protocol in the Mbuf's DATA area at OFFSET and its size
is LENGTH bytes.
The receive status passed to the Receive Upcall in register AL is
always zero, except for protocols using "non-LLC" mode (bit 8 of PCB's
protocol mode field) or "promiscuous" mode together with "receive
error frames" (bits 0 & 3).
Upcalls are FAR routines and must return with a RET FAR. If the Carry
Flag is set on return from a Receive or Transmit Upcall, then ES:BX
must point to an Mbuf, which the DLI will then pass to the RELEASE
BUFFER function (see AX=0005h). See also notes for PROTOCOL MODE.
Event Upcall called with:
AX = event code (see below)
Note: All Event Upcalls may be ignored by the protocol.
Event codes found in register AX on Event Upcall:
00h EV_BUFFER_AVAILABLE client may now call REQUEST BUFFER (AX=0004h)
01h EV_ISR_START start of Interrupt Service Routine
02h EV_ISR_END end of ISR (see bit 1 in PCB's protocol mode field)
03h EV_BUFFER_WANTED DLI temporarily out of Mbufs
04h EV_NETWORK_STATUS DLI 2.8+ network status (DX=status; see below)
05h EV_IO_CONTROL DLI 2.8+ I/O control (DX=subfunction; see AX=0016h)
Bitfields for EV_NETWORK_STATUS in register DX:
Token-Ring FDDI
bit 15 SIGNAL_LOSS SIGNAL_LOSS
bit 14 HARD_ERROR HARD_ERROR
bit 13 SOFT_ERROR SOFT_ERROR
bit 12 TRANSMIT_BEACON TRANSMIT_BEACON
bit 11 LOBE_WIRE_FAULT PATH_TEST_FAILED
bit 10 AUTO_REMOVAL SELF_TEST_REQUIRED
bit 9 reserved reserved
bit 8 REMOVE_RECEIVED REMOTE_DISCONNECT
bit 7 COUNTER_OVERFLOW reserved
bit 6 SINGLE_STATION DUPLICATE_ADDRESS
bit 5 RING_RECOVERY NO_RING_OP_STATUS
bit 4 reserved VERSION_MISMATCH
bit 3 reserved STUCK_BYPASS
bit 2 reserved FDDI_EVENT
bit 1 reserved RING_OP_CHANGE
bit 0 reserved reserved
Note: EV_NETWORK_STATUS is not supported on Ethernet
--------N-7C0008-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DISABLE PROTOCOL
AX = 0008h
BX = protocol ID (see AX=0007h)
Return: AX = completion code (see AX=0001h)
Note: the DLI will handle any Mbufs given to TRANSMIT FRAME (AX=0006h) as if
they had been given to TRANSMIT FRAME RELEASE (AX=0013h).
all multicast addresses registered for this protocol will be disabled.
after this function returns, the protocol's Upcall routines will no
longer be called.
SeeAlso: AX=0007h,AX=000Bh
--------N-7C0009-----------------------------
INT 7C - SK-UPPS Data Link Interface API - REGISTER MULTICAST
AX = 0009h
BX = protocol ID (see AX=0007h)
ES:DI -> multicast address (6 bytes)
Return: AX = completion code (see AX=0001h)
Notes: The broadcast address is always enabled.
Set bit 9 of PCB's protocol mode field in REGISTER PROTOCOL call
(AX=0007h) to receive all multicast frames.
SeeAlso: AX=000Ah,AX=0014h
--------N-7C000A-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DISABLE MULTICAST
AX = 000Ah
BX = protocol ID (see AX=0007h)
ES:DI -> multicast address (6 bytes)
Return: AX = completion code (see AX=0001h)
SeeAlso: AX=0009h,AX=0014h
--------N-7C000B-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET PROTOCOL LIST
AX = 000Bh
ES:DI -> protocol ID buffer
CX = number of 2-byte protocol IDs that may be stored in buffer
Return: AX = completion code (see AX=0001h)
CX = number of active protocols (regardless of value returned in AX)
protocol ID buffer filled with active protocol IDs
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of its Data Link Interface, allowing the
use of any of several network transport layers
Note: If the buffer supplied is too small, CX still contains the total number
of active protocols and the buffer has been filled until full.
SeeAlso: AX=000Ch,AX=0014h
--------N-7C000C-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET PROTOCOL STATUS
AX = 000Ch
BX = protocol ID (see AX=000Bh)
ES:DI -> Protocol Status Block (see below)
Return: AX = completion code (see AX=0001h)
SeeAlso: AX=000Bh,AX=0014h
Format of Protocol Status Block (PSB):
Offset Size Description
00h DWORD -> ASCIZ protocol name
04h WORD protocol mode (see AX=0007h)
06h WORD protocol type (see AX=0007h)
08h WORD number of registered multicasts (see AX=0009h, AX=0014h)
--------N-7C000D-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET DRIVER STATISTICS
AX = 000Dh
BX = flag: 0=don't clear statistics, 1=clear statistics
ES:DI -> Statistics Data Block (see below)
Return: AX = completion code (see AX=0001h)
SeeAlso: AX=0002h,AX=0015h
Format of Statistics Data Block (SDB):
Offset Size Description
00h DWORD node uptime in ticks (1/18.21 sec.)
04h DWORD bytes received
08h DWORD bytes transmitted
0Ch DWORD frames received
10h DWORD frames transmitted
14h DWORD multicast bytes received
18h DWORD multicast frames received
1Ch DWORD unrecognized frames
20h WORD missed frames
22h WORD frame check sequence (FCS) errors
24h WORD framing errors
26h WORD babbling errors
28h WORD late collision errors
2Ah WORD loss of carrier errors
2Ch WORD 16 retries failed errors
2Eh WORD overflow errors
Note: fields 26h through 2Ch are always zero, except in some very old
versions of the DLI. Use GET MEDIA STATISTICS (AX=0015h) to get
more detailed information.
--------N-7C000E-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DLI 2.5+ - GET DRIVER INFO
AX = 000Eh
ES:DI -> Driver Information Block (see below)
BX = offset of 1st field within DIB to be returned
CX = number of bytes to be returned
Return: AX = completion code (see AX=0001h)
CX = number of bytes copied (regardless of value returned in AX)
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of its Data Link Interface, allowing the
use of any of several network transport layers
SeeAlso: AX=0000h,AX=0002h,AX=000Bh,AX=000Dh,AX=0015h
Format of Driver Information Block (DIB):
Offset Size Description
00h 6 BYTEs physical node address (from adapter's ROM)
06h 6 BYTEs current node address (see AX=0003h)
0Ch BYTE adapter id (defined by OEM)
0Dh BYTE IRQ line (FFh if none)
0Eh DWORD -> shared memory (zero if none)
12h DWORD size of shared memory (zero if none)
16h WORD base I/O port (zero if none)
18h BYTE DMA line (FFh if none)
19h BYTE DLI 2.4+ topology (see AX=0000h)
1Ah WORD size of an Mbuf's DATA area (see AX=0004h)
1Ch 2 BYTEs reserved (currently unused)
1Eh WORD total number of Mbufs the DLI has
20h WORD maximum number of Mbufs that can be allocated via REQUEST
BUFFER (AX=0004h) and SYNC REQUEST BUFFER (AX=0012h)
---- end of Status Information Block returned by GET DRIVER STATUS (AX=0002h)
22h DWORD -> ASCIZ adapter name
26h WORD number of I/O ports used (zero if none)
28h DWORD line speed in bits/sec.
--------N-7C000F-----------------------------
INT 7C - SK-UPPS Data Link Interface API - FEED BACK BUFFER
AX = 000Fh
ES:BX -> Mbuf
Return: nothing
Notes: A protocol may call this function instead of returning the Mbuf
directly from the Receive Upcall if it is running in "promiscuous",
"hook" or "chain" mode.
SeeAlso: AX=0007h
--------N-7C0010-----------------------------
INT 7C - SK-UPPS Data Link Interface API - CLIENT HOOK
AX = 0010h
Return: nothing
Notes: An application having no active protocols may call this function to
prevent the DLI from unloading.
SeeAlso: AX=0001h,AX=0011h
--------N-7C0011-----------------------------
INT 7C - SK-UPPS Data Link Interface API - CLIENT UNHOOK
AX = 0011h
Return: nothing
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of its Data Link Interface, allowing the
use of any of several network transport layers
SeeAlso: AX=0010h
--------N-7C0012-----------------------------
INT 7C - SK-UPPS Data Link Interface API - SYNC REQUEST BUFFER
AX = 0012h
DX = protocol ID (see AX=0007h)
Return: AX = completion code (see AX=0001h)
if AX=0000h: ES:BX -> Mbuf (see AX=0004h)
Note: If the protocol wants to be informed when an Mbuf becomes available,
REQUEST BUFFER (AX=0004h) should be used instead.
SeeAlso: AX=0004h,AX=0005h,AX=0006h,AX=0013h
--------N-7C0013-----------------------------
INT 7C - SK-UPPS Data Link Interface API - TRANSMIT FRAME RELEASE
AX = 0013h
ES:BX -> Mbuf (see AX=0004h)
Return: nothing
Notes: Returns immediately; The protocol's Transmit Upcall will NOT be called.
The Mbuf may no more be used by the protocol in any way (i.e. the
Mbuf's IN USE field may not be polled).
SeeAlso: AX=0004h,AX=0013h
--------N-7C0014-----------------------------
INT 7C - SK-UPPS Data Link Interface API - GET MULTICAST LIST
AX = 0014h
BX = protocol ID (see AX=000Bh)
ES:DI -> multicast address buffer
CX = number of 6-byte multicast addresses that may be stored in buffer
Return: AX = completion code (see AX=0001h)
CX = number of registered multicast addresses for this protocol
(regardless of value returned in AX)
multicast address buffer filled with multicast addresses registered for
this protocol
Note: If the buffer supplied is too small, CX still contains the total number
of registered multicast addresses for this protocol and the buffer has
been filled until full.
SeeAlso: AX=000Bh,AX=0009h,AX=000Ch
--------N-7C0015-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DLI 2.6+ - GET MEDIA STATISTICS
AX = 0015h
ES:DI -> media-specific statistics buffer (see below)
BX = offset of 1st field within MSS to be returned
CX = number of bytes to be returned
Return: AX = completion code (see AX=0001h)
CX = number of bytes copied (regardless of value returned in AX)
Note: not supported by all DLIs (will return AX=FFFFh if not supported).
SeeAlso: AX=0000h,AX=000Dh
Format of media-specific statistics for Ethernet:
Offset Size Description
00h DWORD alignment errors
04h DWORD frame check sequence (FCS) errors
08h DWORD single collision frames
0Ch DWORD multiple collision frames
10h DWORD signal quality error (SQE) test errors
14h DWORD deferred transmissions
18h DWORD late collisions
1Ch DWORD excessive collisions
20h DWORD internal MAC transmit errors
24h DWORD carrier sense errors
28h DWORD excessive deferrals
2Ch DWORD frame too longs
30h DWORD in range length errors
34h DWORD out of range length fields
38h DWORD internal MAC receive errors
Format of media-specific statistics for FDDI:
Offset Size Description
00h DWORD SMT operating version id (refer to ANSI 7.1.2.2)
04h DWORD SMT CF state: 1=Isolated, 2= Wrap_S, 3=Wrap_A, 4=Wrap_B,
5=Wrap_AB, 6=Thru (refer to ANSI SMT 9.7.4.3)
08h DWORD SMT frames sent
0Ch DWORD SMT frames received
10h DWORD SMT ring up count
14h 6 BYTEs MAC upstream neighbour
1Ah 6 BYTEs MAC downstream neighbour
20h DWORD MAC frame counter (refer to ANSI MAC 2.2.1)
24h DWORD MAC error counter ( " )
28h DWORD MAC lost counter ( " )
2Ch BYTE port 1 link error estimate (ranges from 10**-4 to 10**-15 and
is reported as the absolute value of the exponent)
2Dh BYTE port 2 link error estimate ( " )
2Eh 2 BYTEs reserved (currently unused)
30h DWORD attachment class: 1=single-attachment (S PORT),
2=dual-attachment (A/B PORT pairs), 3=concentrator (M PORTs)
34h DWORD attachment optical bypass present: 1=true, 2=false
Format of media-specific statistics for Token-Ring:
Offset Size Description
00h 6 BYTEs upstream neighbour
06h WORD local ring number
08h DWORD ring up count
0Ch DWORD signal loss errors
10h DWORD lobe wire faults
14h DWORD ring recovery count
18h DWORD line errors
1Ch DWORD burst errors
20h DWORD ARI/FCI errors
24h DWORD lost frame errors
28h DWORD receive congestion errors
2Ch DWORD frame copied errors
30h DWORD token errors
34h DWORD DMA bus errors
38h DWORD DMA parity errors
3Ch DWORD receive overflow errors
--------N-7C0016-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DLI 2.8+ - DRIVER I/O CONTROL
AX = 0016h
DX = subfunction; bits 14-15 specify direction of I/O:
00 no data at all (ES:BX undefined)
01 driver -> application (GET)
10 application -> driver (SET)
11 both directions (GET/SET)
ES:BX -> I/O buffer (optional)
CX = size of buffer (if ES:BX valid)
Return: AX = completion code; defined by OEM
Program: SK-UPPS is the Schneider & Koch Universal Portable Protocol Stack,
which provides an API on top of its Data Link Interface, allowing the
use of any of several network transport layers
Notes: not supported by all DLIs (will return AX=FFFFh if not supported)
subfunction codes are defined by OEMs
SeeAlso: AX=0001h
--------N-7C0017-----------------------------
INT 7C - SK-UPPS Data Link Interface API - DLI 2.8+ - INTERRUPT REQUEST
AX = 0017h
Return: AX = completion code (see AX=0001h)
Notes: not supported by all DLIs (will return AX=FFFFh, if not supported).
must be called with interrupts disabled; when the client re-enables
interrupts, an interrupt will be generated and reported to the client
through an Event Upcall (see AX=0007h [EV_ISR_START/EV_ISR_END])
SeeAlso: AX=0007h
--------t-7D---------------------------------
INT 7D - [obsoleted proposal] - ALTERNATE MULTIPLEX INTERRUPT
Note: this interface has been moved to INT 2D; there are no known
implementations on INT 7D
SeeAlso: INT 2D,INT 2F
--------S-7D---------------------------------
INT 7D U - YTERM 1.4 - CLOCK SUPPORT
SeeAlso: INT 7E"YTERM"
--------E-7D---------------------------------
INT 7D - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ5
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 0D,INT 7C"GO32",INT 7E"GO32"
--------U-7D---------------------------------
INT 7D - HyperPAD v2.2 - API ACCESS
Note: this vector is hooked but immediately passed on (without checking
whether the previous handler was 0000h:0000h). The sole purpose of
this vector is to provide the address of the data area described
below.
Format of HyperPAD data area:
Offset Size Description
-16h DWORD pointer to ??? FAR function
-12h DWORD pointer to callback setting function
[C calling conventions, (*callback)(int (_loadds far *)()) ]
-0Eh 6 BYTEs signature "BRC001"
-08h DWORD pointer to previous INT 7D handler
-04h DWORD pointer to ??? data
00h HyperPAD INT 7D handler
----------7D---------------------------------
INT 7D - IBM DOS 6.1 E.EXE - ???
Note: E.EXE checks whether this interrupt is in use (not 0000h:0000h),
and if it is used, attempts to load E55VGA.EX instead of the
default E.EX overlay. However, E55VGA.EX is not included in
IBM DOS 6.1.
----------7D00-------------------------------
INT 7D - SCSILink - RESET SCSI BUS
AH = 00h
Program: SCSILink is a TSR by Cross Products Ltd which allows its PC-hosted
cross assemblers and similar products to communicate with Cross
Products hardware debuggers
Desc: reset all devices on the SCSI bus
Note: the installation check is the signature "SCSILINK" immediately prior
to the interrupt handler
Index: installation check;SCSILink
----------7D01-------------------------------
INT 7D - SCSILink - CONNECT TO TARGET
AH = 01h
AL = target ID
Return: CF clear if successful
CF set on error
AL = initiator error
AH = target error
Desc: arbitrate the use of the bus and select the specified target device
----------7D02-------------------------------
INT 7D - SCSILink - SEND COMMAND
AH = 02h
ES:BX -> parameter block (see below)
Return: CF clear if successful
CF set on error
AL = initiator error
AH = target error
Desc: send the specified command block to the target device and perform any
related I/O
Format of parameter block:
Offset Size Description
00h DWORD size of command block
04h DWORD address of command block (see below)
08h DWORD size of buffer
0Ch DWORD address of buffer
Format of command block:
Offset Size Description
00h info not yet available
----------7D03-------------------------------
INT 7D - SCSILink - SET TIMEOUT
AH = 03h
AL = timeout selector (see below)
BX = new value in 55ms ticks
Desc: change an internal timeout value to allow communication with very
slow targets
Values for timeout selector:
00h time to wait for bus (default 18)
01h time to wait for new phase (default 5)
02h maximum time to send/receive block (default 18)
03h time to wait for reselect (default 180)
----------7D04-------------------------------
INT 7D - SCSILink - GET ERROR STRING
AH = 04h
AL = error number
Return: ES:BX -> ASCIZ error string for error number
----------7D05-------------------------------
INT 7D - SCSILink - GET ADDRESS
AH = 05h
Return: AL = DMA channel
AH = initiator ID
BX = card address
Desc: determine the current hardware configuration
----------7D06-------------------------------
INT 7D - SCSILink - PUT DATA
AH = 06h
CX = number of bytes to store (0001h-0100h)
ES:BX -> data to be saved
Return: CF clear if successful
CF set on error
AL = error code (01h = too much data)
Note: the specified data is stored in SCSILink's PSP
SeeAlso: AH=07h
----------7D07-------------------------------
INT 7D - SCSILink - GET DATA
AH = 07h
CX = number of bytes to retrieve (0001h-0100h)
ES:BX -> buffer for data
Return: CF clear if successful
CF set on error
AL = error code (01h = too much data)
Note: retrieve data previously stored with AH=06h
SeeAlso: AH=06h
----------7D08-------------------------------
INT 7D - SCSILink - TERMINATE SESSION
AH = 08h
Desc: indicate to any other programs that intercept INT 7D that the program
has finished with the link
Note: the program should call this function even if a SCSI error caused its
termination
----------7D09-------------------------------
INT 7D - SCSILink - POLL REQUEST
AH = 09h
AL = target ID
Return: AL = status
FEh resident driver experienced SCSI error
FFh resident driver handleded event
Desc: give any drivers chained onto INT 7D a chance to handle an exception
not specifically handled by the calling program
Notes: this service exists so that resident disk servers, etc. can continue
running even while debuggers and profilers are active
the resident driver assumes that a connection has been established and
attempts to leave the target connected
--------*-7E---------------------------------
INT 7E - RESERVED FOR DIP, Ltd. ROM LIBRARY
--------S-7E---------------------------------
INT 7E U - YTERM 1.4 - ???
SeeAlso: INT 7D"YTERM",INT 7F"YTERM"
--------E-7E---------------------------------
INT 7E - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ6
Program: GO32.EXE is a DOS extender included as part of the 80386 port of the
GNU C/C++ compiler by DJ Delorie and distributed as DJGPP
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the extender
SeeAlso: INT 0E,INT 7D"GO32",INT 7F"GO32"
--------m-7E5857BL57-------------------------
INT 7E - XLOAD - INSTALLATION CHECK
AX = 5857h
BL = 57h
Return: AX = 0000h if installed
Program: XLOAD is the LOADHIGH-equivalent from Helix Software's Netroom
SeeAlso: AX=5857h/BL=5Ah,AX=5857h/BL=5Bh
--------m-7E5857BL5A-------------------------
INT 7E - XLOAD - GET ???
AX = 5857h
BL = 5Ah
Return: AX = 0000h
CX = ???
DS:SI -> ???
SeeAlso: AX=5857h/BL=57h,AX=5857h/BL=5Bh
--------m-7E5857BL5B-------------------------
INT 7E - XLOAD - GET XLOAD MEMORY SIZE
AX = 5857h
BL = 5Bh
Return: AX = 0000h
CX = segment of XLOAD TSR
DX = size of memory block in which XLOAD TSR is located
SeeAlso: AX=5857h/BL=57h/AX=5857h/BL=5Ah
--------V-7F---------------------------------
INT 7F - IBM XGA - ???
--------V-7F---------------------------------
INT 7F - Halo88 - API
BX = function
64h arc
65h bar
66h box
67h circle
68h clr
69h default hatch style
6Ah default line style
6Bh delhcur
6Ch delln / deltcur
6Dh ellipse
6Eh fill
6Fh flood
70h flood2
71h init graphics
72h init hcur
73h init marker
74h init tcur
75h inqarc
76h inqbknd
77h inqclr
78h inqerr
79h inqgcur
7Ah inqhcur
7Bh inqmarker
7Dh inqtcur
7Eh inqtext
7Fh lnabs
80h lnrel
81h markerabs
82h markerrel
83h moveabs
84h movehcurabs
85h movehcurrel
86h moverel
87h movetcurabs
88h movetcurrel
89h movefrom
8Ah moveto
8Bh pie
8Ch polylnabs
8Dh polylnrel
8Eh ptabs
8Fh ptrel
91h setasp
92h set color
93h set font
94h set hatch style
95h set line style
97h settext
98h set text color
99h btext
9Ah setseg
9Bh display
9Ch setscreen
9Eh close graphics
9Fh ftinit
A0h ftlocate
A1h ftext
A5h set viewport
A6h set window
A7h set world
AAh ftcolor
ACh initlp
ADh inqasp
AEh inqdev
AFh inqdisplay
B0h inqft
B1h inqftcolor
B2h inqinterlace
B3h inqlpa
B4h inqlpg
B5h inqmode
B6h inqscreen
B7h inqversion
B8h roam
B9h scroll
BAh setieee
BBh set interlace
BCh shift
BDh start graphics
BEh vpan
CBh gwrite
CCh gread
CDh setxor
CEh rbox
CFh rcir
D0h rlnabs
D1h rlnrel
D2h delbox
D3h delcir
D5h setseg2
DCh worldoff
DDh mapwtod
DEh mapdtow
DFh mapwton
E0h mapntow
E1h mapdton
E2h mapntod
E3h inqworld
E4h inqviewport
E5h set line width
E6h lnjoint
E7h set locator
E8h read locator
E9h setdev
EBh setstext
ECh setstclr
EDh setstang
EEh stext
EFh inqstext
F0h setdegree
F1h inqstsize
F2h polyfabs
F3h polyfrel
F4h inqdrange
F5h inqstang
F6h orglocator
F7h inqlocator
F8h inqarea
F9h setipal
FAh setborder
FBh inqcrange
FEh setclip
FFh fcir
100h setcrange
101h setdrange
102h setlattr
103h polycabs
104h polycrel
108h memcom
109h memexp
10Ah memmov
10Eh movefx
10Fh movetx
110h inqrgb
111h save image
112h restore image
113h setapal
114h setxpal
118h inqtsize
12Eh gprint
130h setprn
131h setpattr
133h setbattr
135h pexpand
136h ptnorm
137h pfnorm
13Bh inqprn
13Ch lopen
13Dh lclose
13Eh lappend
13Fh lrecord
140h lswitch
142h inqfun
15Dh lsetup
15Eh lrest
15Fh lsave
additional parameters on stack
Return: ???
Program: Halo88 is a suite of graphics routines
Note: according to Stuart Kemp, the code appears to make no provisions for
chaining
--------N-7F---------------------------------
INT 7F - CONVERGENT TECHNOLOGIES ClusterShare CTOS ACCESS VECTOR
AL = request ID
01h "Request"/"RequestDirect"
ES:BX -> pRq
DX ignored
04h "Wait"
ES:BX -> ppMsgRet
DX = exchange
05h "AllocExch"
ES:BX -> pExchRet
06h "DeAllocExch"
DX = exchange
07h "Check"
ES:BX -> ppMsgRet
DX = exchange
CX = 4354h ('CT')
Return: AX = status
0000h successful
--------S-7F---------------------------------
INT 7F - Telebit ACS SERIAL I/O
ES:SI-> parameter block
Return: CF set on error
CF clear on success
Notes: the signature "PDGATEWRKSTNIF" appears just prior to the interrupt
handler; this serves as the installation check
Index: installation check;Telebit ACS Serial I/O
Format of Telebit ACS parameter block:
Offset Size Description
00h BYTE command (see below)
01h BYTE gateway number
02h BYTE reserved
03h BYTE port
04h 17 BYTEs auxiliary buffer
15h BYTE session
16h WORD count of bytes passed to API
18h DWORD buffer pointer passed to/from API
1Ch WORD count of bytes passed from API
1Eh BYTE return code (see below)
Values for command:
3Ch status
3Dh connect
3Eh disconnect
3Fh read
40h data/command write
41h clear receive buffer
42h get configuration
43h get receiver status
44h raw write
45h search servers
46h set transmit buffer size
Values for return code:
00h success
01h invalid session
05h servername invalid
06h NetWare fileserver bindery is locked
07h communication server not active
08h general failure in NetWare fileserver
09h not logged into a fileserver
10h connection table full
11h no response from communication server
12h connection attempt terminated abnormally
13h connection refused - no sessions available
14h gateway number/port already in use
15h invalid connection response
16h port invalid
17h incorrect version in server response
18h gateway number/port combination not configured
19h initialization has not been completed
20h no more sockets are available
21h no active poolname
23h FATAL internal interface error
24h registration of host workstation failed - name is already in use
25h registration of host workstation failed - workstation name table full
26h registration of host workstation failed - only one session may be
registered for dial-in
FFh Telebit ACS API is busy - retry later
--------N-7F---------------------------------
INT 7F - Non-dedicated NetWare 2.x File Server - ENTER CONSOLE MODE
Notes: the installation check consists of checking for the signature "Lynn"
in the four bytes preceding the interrupt handler; if present, the
current program is running as a DOS task on a non-dedicated NetWare
2.x file server.
Before placing the server into "console" mode, it is recommended that
NetWare broadcast messages be disabled with INT 21/AX=DE00h.
SeeAlso: INT 21/AX=DE00h
Index: installation check;non-dedicated NetWare server
--------S-7F---------------------------------
INT 7F U - YTERM - ???
SeeAlso: INT 7E"YTERM"
--------E-7F---------------------------------
INT 7F - DJGPP GO32.EXE DOS EXTENDER - RELOCATED IRQ7
Note: this vector is overwritten when GO32 starts but is not restored by
early versions of the DOS extender
SeeAlso: INT 0F,INT 7E"GO32"
----------7F---------------------------------
INT 7F - Canon IXHND2 Scanner Interface
--------N-7F---------------------------------
INT 7F - Alloy 386/MultiWare (MW386), Novell-Type Network Executive (NTNX)
Notes: the words at C800h:0000h and C800h:0002h will both be 584Eh if the
MW386 multitasking system is present (i.e. signature "NXNX")
NTNX allows its API to be placed on a different interrupt than 7Fh at
load time. To determine the actual vector used, open the device
"SPOOLER" with INT 21/AX=3D02h, place it in RAW mode with
INT 21/AX=4400h and INT 21/AX=4401h, then read one byte which will
be the actual interrupt number being used; the other interrupts may
be found with INT 7F/AH=09h/CL=03h
--------N-7F---------------------------------
INT 7F - Alloy NetWare Support Kit (ANSK) v2.2+ - INSTALLATION CHECK
Note: a program may determine that it is running on an ANSK Slave by checking
the five bytes at F000h:0000h for the ASCIZ signature "ANSK"; this
address is RAM, and should not be written. However, the above check
will not work on Slaves with <1MB RAM or those using the SLIM.SYS
device driver
--------N-7F00-------------------------------
INT 7F - Alloy NTNX, MW386 - SEMAPHORE LOCK AND WAIT
AH = 00h
DS:DX -> ASCIZ semaphore name (max 64 bytes)
Return: AL = status (see below)
AH = semaphore owner if status=02h
SeeAlso: AH=01h,AH=02h,AH=41h,INT 67/AH=00h
Values for status:
00h successful
01h invalid function
02h semaphore already locked
03h unable to lock/unlock semaphore
04h semaphore space exhausted
05h host/target PC did not respond (NTNX)
--------N-7F00-------------------------------
INT 7F - G8BPQ - proposed addition - GET NODE/SWITCH VERSION AND DESCRIPTION
AH = 00h
ES:SI -> buffer for "USERS" text string
Return: AH = major version
AL = minor version
CX = length of returned string
Program: the G8BPQ AX25 Networking Package is amateur packet radio software by
John Wiseman which allows a PC to act as a node in an AX.25 network
SeeAlso: AH=01h"G8BPQ",AH=09h"G8BPQ"
--------N-7F01-------------------------------
INT 7F - Alloy NTNX, MW386 - SEMAPHORE LOCK
AH = 01h
DS:DX -> ASCIZ semaphore name (max 64 bytes)
Return: AL = status (see AH=00h)
AH = semaphore owner if status=02h
SeeAlso: AH=00h,AH=02h,AH=41h
--------V-7F01-------------------------------
INT 7F - TIGA Communications Driver v2.05 - GET ENTRY POINTS
AH = 01h
Return: BX = 1234h if installed
DX:AX -> array of FAR entry points
CH = driver major version
CL = driver minor version
Note: TIGACD 2.05 returns CF set on unrecognized functions in AX
SeeAlso: AX=1234h,AX=4321h
--------N-7F01-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - SET APPLICATION FLAGS AND MASK
AH = 01h
AL = stream number (01h-40h)
CL = new application flags
bit 7: monitored frames available via AH=0Bh"G8BPQ"
DL = new application mask
Program: the G8BPQ AX25 Networking Package is amateur packet radio software by
John Wiseman which allows a PC to act as a node in an AX.25 network
Note: INT 7Fh is the default, which may be changed in the configuration file
for v4.03+
SeeAlso: AH=00h"G8BPQ",AH=02h"G8BPQ",AH=0Bh"G8BPQ"
--------I-7F0104BX0000-----------------------
INT 7F - HLLAPI (IBM 3270 High-Level Language API)/LLAPI (Rabbit Low Level API)
AX = 0104h (HLLAPI gate ID)
BX = 0000h
DS:SI -> parameter control block (see below)
Return: parameter control block updated
SeeAlso: AX=0105h,AX=ABCDh
Format of parameter control block:
Offset Size Description
00h 3 BYTEs signature = 'PCB'
03h BYTE function number (see below)
04h WORD segment of control string
06h WORD offset of control string
08h WORD length of control string, unless explicit end-of-str char set
0Ah BYTE unused (IBM)
ControlString[0] (Rabbit)
0Bh WORD return code (see below)
0Dh WORD maximum length of control string (IBM)
unused (Rabbit)
Values for HLLAPI function number:
00h OEM function (Query system for Attachmate implementation)
01h Connect presentation space
02h Disconnect presentation space
03h Send string of keystrokes as if typed from keyboard
04h Wait ~60s, returns status of presentation space
05h Copy current presentation space into a user-defined buffer
06h Search presentation space for first occurrence of a specified string
07h Query cursor location in current presentation space
08h Copy part or all of current presentation space into user buffer
09h Set session parameters; parameters vary by vendor
0Ah Get info on sessions currently connected
0Bh Lock current presentation space
0Ch Unlock previously locked presentation space
0Dh Return copy of operator info area (OIA) of current presentation space
0Eh get attribute byte for given position in the current presentation space
0Fh copy string of characters to the current presentation space
10h workstation control functions
11h storage manager functions, intended primarily for BASIC applications
(not implemented by Rabbit)
12h set delay period in half-second intervals
14h get info on level of workstation support used
15h reset session parameters to default values
16h get detailed info on the current session
17h start host notification to application on presentation sp or OIA update
18h check host update when host notification enabled
19h stop host notification
1Eh search field within current presentation space for string
1Fh get first positionof a selected field in the current presentation space
20h get length of specified field
21h copy string into a specified field
22h copy specified field into a user-defined buffer
23h create alternate presentation space (IBM only), don't use with BASIC
24h switch to alternate presentation space (IBM only), not with BASIC
25h display cursor in specified area (IBM only), don't use with BASIC
26h display alternate presentation space (IBM only), don't use with BASIC
27h delete alternate presentation space (IBM only), don't use with BASIC
28h set cursor
29h start Close Intercept
2Ah query Close Intercept
2Bh stop Close Intercept
32h start intercepting keystrokes to allow filtering
33h get keystrokes after turning on interception
34h notify operator when keystroke rejected by filter subroutine
35h stop intercepting keystrokes
5Ah send file
5Bh receive file
5Ch run a program (not implemented by Rabbit)
5Dh execute DOS command (not implemented by Rabbit)
63h change presentation space position to PC display row/col or vice versa
65h connect to Window Services
66h disconnect from Window Services
67h set/query window coordinates
68h set/query window status
69h change presentation space name
78h connect Structured Fields
79h disconnect Structured Fields
7Ah query size of communications buffer
7Bh allocate communications buffer
7Ch free communications buffer
7Dh get request completion state
7Eh read Structured Fields
7Fh write Structured Fields
FFh Get info on DCA implementation
Values for LLAPI function number:
80h initialize LLAPI (internal call)
83h set Session ID (one-character ID)
84h read Session ID (one-character ID)
85h lock 327x keyboard
86h unlock 327x keyboard
87h wait for Clear to Send
88h type ASCII character
89h type 327x key
8Ah read keyboard lock state
8Fh force screen update
90h view session
91h relinquish (suspend foreground until background becomes idle)
92h poke screen character
93h poke translated character
94h peek screen character
95h peek translated character
96h set cursor position
97h send scan code (Rabbit only)
98h synchronize (returns after keystroke queue empty)
99h type PC key (Rabbit only)
Session Parameters for function 09h:
ASCII ??? (Rabbit only)
ATTRIB return attributes in hex
NOATTRIB return attributes as blanks
CONPHYS make physical connection
CONLOG only make logical connection
EAB copy extended attribute bytes along with data
NOEAB copy data only
ESC=n set escape character to "n" (default '@')
EOT=n set end of string character (default 00h)
FPAUSE full-duration pause
FTNOWAIT return immediately from functions 5Ah and 5Bh (Rabbit only)
FTWAIT wait for file transfer to complete (Rabbit only)
IPAUSE interruptable pause
RABESC ??? (Rabbit only)
NORABESC ??? (Rabbit only)
SCANCODE ??? (Rabbit only)
STRLEN use explicit string lengths
STREOT use terminated strings
SRCHALL search entire presentation space
SRCHFROM search from specified offset
SRCHFRWD search forward from position 1
SRCHBKWD search backward from last position in presentation space
TIMEOUT=n ??? (Rabbit only)
TWAIT wait specified time for keyboard ready
LWAIT wait until keyboard ready
NWAIT no wait
TRON enable tracing
TROFF disable tracing
AUTORESET send reset before sending keys with function 03h
NORESET don't send reset
QUIET don't display messages sent with INT 21/AH=09h
NOQUIET allow messages to be displayed
TIMEOUT=n set timeout in 30-second intervals, 0 = wait until ^Break
XLATE translate extended attribute bytes
NOXLATE don't translate
NEWRET use HLLAPI v3.0 return code conventions
OLDRET use HLLAPI v2.0 return code conventions
Values for Windows HLLAPI return code:
00h successful
01h Presentation Space not connected/requested size unavailable
02h invalid function or parameter error/invalid block ID
03h file transfer complete
04h file transfer complete (segmented)/Presentation Space busy
05h inhibited or keyboard locked
06h data truncated
07h invalid Presentation Space position
08h operation not available
09h system error
0Ah blocking error
0Bh resource not available
0Ch session stopped
14h undefined key combination
15h OIA updated
16h Presentation Space updated
17h both Presentation Space and OIA updated
18h no such field
19h no keystrokes available
1Ah Presentation Space or Operator Information Area changed
1Bh file transfer aborted
1Ch zero-length field
1Eh cursor type invalid
1Fh keystroke overflow
20h another application is already connected
22h message sent to host cancelled
23h transmission from host cancelled
24h lost contact with host
25h function successful
26h function incomplete
27h a DDM session is already connected
28h disconnected, but asynchronous requests still pending
29h buffer already in use
2Ah no matching request found
12Dh invalid function number
12Eh file not found
131h access denied
134h out of memory
136h environment invalid
137h format invalid
270Eh (9998) invalid Presentation Space ID
270Fh (9999) invalid row or column code
---Windows HLLAPI extensions---
F000h asynchronous call already in progress
F001h invalid asynchronous task ID
F002h blocking call cancelled
F003h underlying subsystem not started
F004h unsupported application version
--------V-7F0105-----------------------------
INT 7F - HDILOAD.EXE - 8514/A VIDEO CONTROLLER INTERFACE
AX = 0105h
Return: CF set on error
CF clear if successful
CX:DX -> array of FAR pointers to entry points
Note: most functions are invoked by pushing the DWORD parameter block pointer
and then performing a FAR call via the appropriate vector of the
entry point array
SeeAlso: AX=0104h,AX=ABCDh
Function numbers: (do FAR call via entry_points+4*function)
08h HOPEN
10h HINT
13h HLDPAL
15h HBBW
17h HBBR
18h HBBCHN
1Dh HQMODE
22h HCLOSE
30h HINIT
31h HSYNC
39h HSPAL
3Ah HRPAL
--------N-7F02-------------------------------
INT 7F - Alloy NTNX, MW386 - RELEASE SEMAPHORE
AH = 02h
DS:DX -> ASCIZ semaphore name (max 64 bytes)
Return: AL = status (see AH=00h"NTNX")
AH = semaphore owner if status=02h
SeeAlso: AH=00h,AH=01h,AH=42h
--------N-7F02-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - SEND FRAME
AH = 02h
AL = stream number (01h-40h)
CX = length of frame
ES:SI -> frame to be sent
SeeAlso: AH=03h"G8BPQ",AH=07h"G8BPQ",AH=0Ah"G8BPQ"
--------f-7F0200-----------------------------
INT 7F - Btrieve Multi-User - GIVE UP TIME???
AX = 0200h
SeeAlso: INT 2F/AX=AB01h,INT 2F/AX=AB02h,INT 7B"Btrieve"
--------N-7F03-------------------------------
INT 7F - Alloy ANSK, NTNX, MW386 - GET USER NUMBER
AH = 03h
Return: AL = user number
AH = machine number (MW386)
Note: this function call is the recommended method for a CPU-bound process to
prevent its priority from being lowered
SeeAlso: AH=04h,AH=05h,AH=A1h
--------N-7F03-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - RECEIVE FRAME
AH = 03h
AL = stream number (01h-40h)
ES:DI -> buffer for frame (must be large enough for a full frame; 350
bytes is usually sufficient)
Return: BX = number of pending frames (0000h if returned frame was last avail)
CX = length of received frame
SeeAlso: AH=02h"G8BPQ",AH=07h"G8BPQ",AH=0Bh"G8BPQ"
--------N-7F04-------------------------------
INT 7F - Alloy NTNX, MW386 - GET NUMBER OF USERS
AH = 04h
Return: AL = total number of users on currrent machine (MW386)
AL = number of slaves on system (NTNX)
SeeAlso: AH=03h
--------N-7F04-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - GET STREAM STATUS
AH = 04h
AL = stream number (01h-40h)
Return: CX = state (0000h disconnected, 0001h connected)
DX = delta state (0000h no change, 0001h changed since last check)
SeeAlso: AH=02h"G8BPQ",AH=05h"G8BPQ"
--------N-7F05-------------------------------
INT 7F - Alloy NTNX (Host) - LOCK/UNLOCK SYSTEM, SPOOLER CONTROL
AH = 05h
AL = function
00h lock system (disable slave services)
01h unlock system
02h enable spooler
03h disable spooler
04h enable slave timer update
05h disable slave timer update
06h enable form feeds
07h disable form feeds
SeeAlso: INT 17/AH=A4h
--------N-7F05-------------------------------
INT 7F - Alloy NTNX (Slave), MW386 - GET USER PARAMETERS
AH = 05h
DX:DI -> buffer for user information record (see below)
Notes: MW386 provides this function for backward compatibility only, and sets
many of the fields to zero because they are meaningless under MW386
this function has no effect when called by the host (user 0)
SeeAlso: AH=03h
Format of user information record:
Offset Size Description
00h WORD segment of video RAM
02h WORD segment of secondary copy of video RAM
04h WORD offset of screen update flag (see INT 10/AH=8Bh)
flag nonzero if update needed
06h WORD video NMI enable port
(not used by MW386, set to 0000h)
08h WORD video NMI disable port
(not used by MW386, set to 0000h)
0Ah BYTE processor type
00h 8088
01h V20
02h 8086
03h V30
06h 80386
0Bh WORD multitasking flag (00h = single tasking, 01h = multitasking)
(not used by MW386, set to 0000h)
0Dh WORD offset of terminal driver
(not used by MW386, set to 0000h)
0Fh BYTE port for console I/O
(not used by MW386, set to 0000h)
10h WORD offset of processor communication busy flag
bit 7 set when slave communicating with host
12h WORD pointer to FAR NX system call
(not used by MW386, set to 0000h)
14h WORD offset of 16-byte user configuration record (see AH=38h)
16h WORD offset of command/status word
18h WORD offset of screen valid flag (see INT 10/AH=93h)
nonzero if screen must be repainted
1Ah WORD offset of screen repaint flag
1Ch WORD pointer to NEAR NX system call
(not used by MW386, set to 0000h)
1Eh WORD offset for intercept flags
(not used by MW386, set to 0000h)
intercept flag = FFh if MS-DOS intercepts should be disabled
20h WORD offset of terminal lock flag (see INT 10/AH=92h)
lock flag = FFh if backgrnd screen updates should be suspended
22h 26 BYTEs reserved
--------N-7F05-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - ACKNOWLEDGE STREAM STATUS CHANGE
AH = 05h
AL = stream number (01h-40h)
Note: this function must be called in order to receive a report of another
status change
SeeAlso: AH=04h"G8BPQ"
--------N-7F06-------------------------------
INT 7F - Alloy NTNX (Host) - GET SHARED DRIVE INFO
AH = 06h
AL = drive number (1=A:, 2=B:, etc)
ES:DI -> drive info record (see below)
Return: AX = status
0000h successful
ES:DI buffer filled
0001h not shared drive
Format of drive info record:
Offset Size Description
00h WORD segment of drive IO-REQUEST structure (MS-DOS DPB)
02h WORD segment of allocation map (owner table)
one byte per FAT entry, containing user ID owning that entry
04h WORD segment of master FAT for drive (copy of FAT on disk)
06h WORD pointer to configuration file
08h WORD total number of clusters
0Ah WORD bytes per sector
0Ch WORD sectors per cluster
0Eh BYTE FAT type (0Ch = 12-bit, 10h = 16-bit)
--------N-7F06-------------------------------
INT 7F - Alloy NTNX (Slave) - ALLOCATE FREE CLUSTER ON SHARED DRIVE
AH = 06h
DL = drive number (1=A:,2=B:,etc)
CX = number of clusters to allocate
Return: AH = status
00h successful
CX = number of clusters still free
10h invalid shared drive request
CL = first and second shared drives
11h invalid cluster count (must be 01h-FFh)
--------N-7F06-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - SESSION CONTROL
AH = 06h
AL = stream number (01h-40h)
CX = subfunction
0000h connect to node
DL bit 0: use BBS callsign instead of Node Call
0001h connect ot node
use BBS Call if APPLMASK=1
0002h disconnect
0003h return user to node
SeeAlso: AH=01h"G8BPQ",AH=04h"G8BPQ"
--------N-7F07-------------------------------
INT 7F - Alloy NTNX, MW386 - GET LIST OF SHARED DRIVES
AH = 07h
Return: ES:DI -> shared drive list (see below)
Note: MW386 considers all fixed disks to be shared drives; only C and D will
be returned as shared
Format of shared drive list:
Offset Size Description
00h BYTE string length
01h BYTE number of shared drives
02h N BYTEs one byte per shared drive
--------N-7F07-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - GET BUFFER COUNTS FOR STREAM
AH = 07h
AL = stream number (01h-40h)
Return: BX = number of pending receive frames
CX = number of unacknowledged sent frames
DX = number of buffers available
SeeAlso: AH=02h"G8BPQ",AH=03h"G8BPQ"
--------N-7F08-------------------------------
INT 7F - Alloy NTNX (Host) - GET INTERRUPT VECTORS
AH = 08h
CL = function
00h get original interrupt vector
01h get Network Executive interrrupt
AL = interrupt number
DX:SI -> DWORD to hold interrupt vector
Return: AL = status
00h successful
01h interrupt vector not used by network executive
02h invalid subfunction
Note: the network executive uses interrupts 02h,08h,09h,0Fh,10h,13h,16h-19h,
1Ch,20h,28h,2Ah,2Fh,5Bh,67h,7Fh,ECh, and F0h-FFh
SeeAlso: AH=09h/CL=03h,INT 21/AH=35h
--------N-7F08--CL02-------------------------
INT 7F - Alloy NTNX - SET MESSAGE DISPLAY TIMEOUT
AH = 08h
CL = 02h
DX = timeout in seconds
Return: AL = status
00h successful
02h invalid subfunction
--------N-7F08-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - PORT CONTROL/INFORMATION
AH = 08h
AL = stream number (01h-40h)
Return: ES:DI -> 10-byte buffer containing blank-padded callsign
---v4.05+ ---
AL = radio port to which channel is connected (level 2)
AH = session type (see below)
BX = L2 paclen for session
CX = maximum frame size
DX = L4 window size or 0000h if not L4 circuit
Program: the G8BPQ AX25 Networking Package is amateur packet radio software by
John Wiseman which allows a PC to act as a node in an AX.25 network
SeeAlso: AH=01h"G8BPQ",AH=02h"G8BPQ",AH=03h"G8BPQ",AH=0Ah"G8BPQ"
Bitfields for session type:
bit 0 L2LINK
bit 1 SESSION
bit 2 UPLINK
bit 3 DOWNLIND
bit 5 BPQHOST
--------T-7F09-------------------------------
INT 7F - MultiLink Advanced - SET TASK PRIORITY
AH = 09h
AL = priority (0-7)
Note: the installation check consists of ensuring that the interrupt vector
is not pointing at segment 0000h, then checking whether the byte
at offset 0000h in the interrupt handler's segment is E9h
Index: installation check;MultiLink Advanced
--------N-7F09-------------------------------
INT 7F - G8BPQ - proposed addition - GET NODE/APPLICATION CALLSIGN AND ALIAS
AH = 09h
AL = application
00h node
01h BBS
02h HOST
03h SYSOP
BL = what to get (00h callsign, 01h application name)
ES:SI -> buffer for callsign/name string
Return: CX = length of returned string
SeeAlso: AH=00h"G8BPQ",AH=01h"G8BPQ",AH=0Ch"G8BPQ"
--------N-7F09-------------------------------
INT 7F - Alloy NTNX - ENABLE/DISABLE MUD FILE CHECKING
AH = 09h
CL = function
00h enable checking of RTNX.MUD file
01h disable RTNX.MUD checking
--------N-7F09--CL02-------------------------
INT 7F - Alloy NTNX - SWITCH HOST TO DEDICATED MODE
AH = 09h
CL = 02h
Note: in dedicated mode, the host will only poll for I/O requests from the
slave processors, and not provide workstation services
--------N-7F09--CL03-------------------------
INT 7F - Alloy NTNX,MW386 - GET ALTERNATE INTERRUPT
AH = 09h
CL = 03h
AL = default interrupt number (67h,7Fh,etc)
Return: CL = actual interrupt which handles specified interrupt's calls
SeeAlso: AH=08h
--------N-7F0A--CL00-------------------------
INT 7F - Alloy NTNX - GET SYSTEM FLAGS
AH = 0Ah
CL = 00h
ES:DI -> buffer for system flags (see below)
Return: ES:DI buffer filled
Notes: on a slave, only the NX_Busy flag is returned
all three flags are at fixed positions, so this function only needs to
be called once
an interrupt handler should only perform DOS or device accesses when
all three flags are 00h
Format of system flags:
Offset Size Description
00h DWORD pointer to NX_Busy flag (nonzero when communicating with users)
04h DWORD pointer to device driver busy flag
08h DWORD pointer to InTimer flag
--------N-7F0A-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - TRANSMIT RAW (KISS) FRAME
AH = 0Ah
AL = radio port
ES:SI -> buffer containing data to be sent
CX = number of bytes to send
SeeAlso: AH=02h"G8BPQ",AH=08h"G8BPQ",AH=0Bh"G8BPQ"
--------N-7F0B--CL02-------------------------
INT 7F - Alloy NTNX (Host) - SET/RESET GRAPHICS DOS ON SLAVE
AH = 0Bh
CL = 02h
AL = slave ID number
CH = DOS to activate
00h graphics DOS
01h character DOS
Return: AL = status
00h successful
01h nothing done, proper DOS type already loaded
--------N-7F0B-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - RECEIVE TRACE (RAW DATA) FRAME
AH = 0Bh
ES:DI -> buffer for received data (see below)
Return: CX = number of bytes received
Note: the specified buffer must be large enough to receive a full frame
SeeAlso: AH=03h"G8BPQ",AH=08h"G8BPQ",AH=0Ah"G8BPQ"
Format of received data:
Offset Size Description
00h WORD internal control information
02h BYTE port number (bit 7 set if transmitted frame)
03h WORD frame length including this header
05h var user data
--------N-7F0C-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - UPDATE SWITCH INFORMATION
AH = 0Ch
DX = function
0001h update beacon text
CX = length of data
ES:SI -> data to be sent in beacons
SeeAlso: AH=09h"G8BPQ"
--------N-7F0F-------------------------------
INT 7F - G8BPQ v4.00+ - HOST MODE - GET TIME MARKER
AH = 0Fh
Return: AX = time marker (clock ticks modulo 64K)
Program: the G8BPQ AX25 Networking Package is amateur packet radio software by
John Wiseman which allows a PC to act as a node in an AX.25 network
SeeAlso: AH=01h"G8BPQ",INT 1A/AH=00h
--------N-7F10--CL00-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - OPEN CHANNEL
AH = 10h
CL = 00h
AL = channel number
DX:DI -> channel buffer
Return: AL = status (00h-03h,0Dh) (see below)
Note: may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=01h,AH=10h/CL=04h,AH=14h/CL=02h
Values for status:
00h successful
01h busy
02h channel range error (not 00h-3Fh)
03h invalid subfunction
0Ah channel not open
0Ch channel already locked
0Dh unable to open
--------N-7F10--CL01-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - CLOSE CHANNEL
AH = 10h
CL = 01h
AL = channel number
Return: AL = status (00h-03h,0Ah) (see AH=10h/CL=00h)
Note: may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=00h,AH=10h/CL=05h
--------N-7F10--CL02-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - LOCK CHANNEL
AH = 10h
CL = 02h
AL = channel number
Return: AL = status (00h-03h,0Ah,0Ch) (see AH=10h/CL=00h)
Note: may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=03h,AH=10h/CL=06h,AH=10h/CL=08h
--------N-7F10--CL03-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - UNLOCK CHANNEL
AH = 10h
CL = 03h
AL = channel number
Return: AL = status (00h-03h,0Ah) (see AH=10h/CL=00h)
Notes: should only be used on channels locked with AH=10h/CL=02h, not on those
locked by receipt of a datagram
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=02h,AH=10h/CL=04h,AH=10h/CL=09h
--------N-7F10--CL04-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - RELEASE BUFFER
AH = 10h
CL = 04h
AL = channel number
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Notes: unlocks buffer after received datagram has been processed
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=00h
--------N-7F10--CL05-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - CLOSE ALL CHANNELS
AH = 10h
CL = 05h
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Notes: clears all pending datagrams and clears buffer pointers before closing
the channels
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=01h
--------N-7F10--CL06-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - LOCK ALL OPEN CHANNELS
AH = 10h
CL = 06h
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Note: may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=02h,AH=10h/CL=08h
--------N-7F10--CL07-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - UNLOCK ALL LOCKED IDLE CHANNELS
AH = 10h
CL = 07h
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Notes: unlocks all locked channels which have no pending datagrams
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=03h,AH=10h/CL=09h
--------N-7F10--CL08-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - LOCK MULTIPLE CHANNELS
AH = 10h
CL = 08h
DX = maximum channel number to lock
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Notes: locks channels numbered 00h through the value in DX
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=02h,AH=10h/CL=06h,AH=10h/CL=09h
--------N-7F10--CL09-------------------------
INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - UNLOCK MULTIPLE CHANNELS
AH = 10h
CL = 09h
DX = maximum channel number to unlock
Return: AL = status (00h-03h) (see AH=10h/CL=00h)
Notes: unlocks channels numbered 00h through the value in DX
may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=03h,AH=10h/CL=07h,AH=10h/CL=08h
--------N-7F11-------------------------------
INT 7F - Alloy NTNX, MW386 - SEND DATAGRAM
AH = 11h
DX:SI -> request block (see below)
Return: AL = status (see below)
Note: if wildcard channel FFh used, actual channel number will be filled in
SeeAlso: AH=12h
Values for status:
00h successful
01h busy
02h channel range error (not 00h-3Fh)
03h invalid subfunction
0Ah packet too large (or <2 bytes if NTNX)
0Bh can't send packet to itself
0Ch invalid number of destinations
0Dh destination channel number out of range
0Eh destination user is busy
0Fh destination user has locked channel
10h channel not open
11h no datagram server on destination (NTNX)
Format of request block:
Offset Size Description
00h DWORD pointer to packet to send
04h WORD packet size in bytes (1-4096)
06h BYTE number of destinations for packet (max 1Fh)
07h 31 BYTEs destination user IDs (FFh = broadcast to all except sender)
26h 31 BYTEs destination channels (FFh = first available channel)
45h 31 BYTEs return destination statuses
--------N-7F12-------------------------------
INT 7F - Alloy NTNX, MW386 - ACKNOWLEDGE DATAGRAM
AH = 12h
AL = channel number being acknowledged
DI:DX = 32-bit status to return to sender
Return: AL = status (see below)
Note: also unlocks the channel, allowing the next datagram to be received
SeeAlso: AH=11h,AH=15h/CL=04h
Values for status:
00h successful
01h busy
02h channel range error (not 00h-3Fh)
03h invalid subfunction
0Ah channel not open
0Bh no message in channel
0Ch destination slave busy--retry (NTNX)
0Dh destination user not active
0Eh destination slave not active (NTNX)
0Fh destination disabled datagram service
--------V-7F1234-----------------------------
INT 7F - TIGA Communications Driver v2.05 - UNINSTALL
AX = 1234h
SeeAlso: AX=4321h
--------N-7F13--CL00-------------------------
INT 7F - Alloy NTNX, MW386 - RESET USER DATAGRAMS
AH = 13h
CL = 00h
Note: clears all pending datagrams and removes all channels opened in NTNX
compatibility mode
--------N-7F14--CL00-------------------------
INT 7F - Alloy NTNX, MW386 - SET RECEIVE ISR
AH = 14h
CL = 00h
DX:DI -> application FAR receive service routine (see below)
Return: AL = status (00h-03h) (see AH=12h)
SeeAlso: AH=14h/CL=01h,AH=14h/CL=03h
Service routine called with:
DH = sender ID
DL = channel with datagram
interrupts disabled
Return: AL = response code
00h leave buffer locked, set channel status, and repeat call later
01h release channel buffer
02h change buffer pointer to DX:DI
AH,CX,DX,DI,SI may be destroyed
--------N-7F14--CL01-------------------------
INT 7F - Alloy NTNX, MW386 - SET ACKNOWLEDGE ISR
AH = 14h
CL = 01h
DX:DI -> application FAR acknowledge service routine (see below)
Return: AL = status (00h-03h) (see AH=12h)
Note: the service routine will be called as soon as an acknowledgment arrives
SeeAlso: AH=12h,AH=14h/CL=00h,AH=14h/CL=04h,AH=15h/CL=04h
Service routine called with:
DS:SI -> acknowledge structure (see AH=15h/CL=04h)
Return: AL = response code
00h application busy, network executive should call again later
01h acknowledge accepted
AH,DX,SI may be destroyed
--------N-7F14--CL02-------------------------
INT 7F - Alloy NTNX, MW386 - SET CHANNEL BUFFER POINTER
AH = 14h
CL = 02h
AL = channel number
DX:DI -> receive buffer
Return: AL = status (00h-03h) (see AH=12h)
Note: may be called from within a receive ISR or when a datagram is pending
SeeAlso: AH=10h/CL=00h,AH=14h/CL=00h
--------N-7F14--CL03-------------------------
INT 7F - Alloy NTNX, MW386 - GET RECEIVE ISR
AH = 14h
CL = 03h
Return: DX:DI -> current receive ISR
SeeAlso: AH=14h/CL=00h,AH=14h/CL=04h
--------N-7F14--CL04-------------------------
INT 7F - Alloy NTNX, MW386 - GET ACKNOWLEDGE ISR
AH = 14h
CL = 04h
Return: DX:DI -> current acknowledge ISR
SeeAlso: AH=14h/CL=01h,AH=14h/CL=03h
--------N-7F14--CL05-------------------------
INT 7F - Alloy NTNX (Host), MW386 - GET BUSY POINTER
AH = 14h
CL = 05h
DX:DI -> buffer for busy structure (see below)
Return: DX:DI buffer filled
Format of busy structure:
Offset Size Description
00h DWORD pointer to busy flag byte
04h WORD fixed port address (FF00h)
--------N-7F15--CL00-------------------------
INT 7F - Alloy NTNX, MW386 - GET CHANNEL STATUS
AH = 15h
CL = 00h
AL = channel number
DX:DI -> status structure (see below)
Return: AL = status (00h-03h) (see AH=12h)
SeeAlso: AH=15h/CL=01h
Format of status structure:
Offset Size Description
00h BYTE channel status
bit 0: channel open
bit 1: channel buffer contains received data
bit 7: channel locked
01h BYTE sender ID
--------N-7F15--CL01-------------------------
INT 7F - Alloy NTNX, MW386 - GET NEXT FULL CHANNEL
AH = 15h
CL = 01h
DX:DI -> full-channel structure
Return: AL = status
00h successful
01h busy
0Ah no datagrams available
Note: MW386 v1.0 returns the lowest channel with a datagram; newer versions
and NTNX return the oldest datagram
SeeAlso: AH=15h/CL=00h
Format of full-channel structure:
Offset Size Description
00h BYTE number of channel with oldest datagram
01h BYTE sender ID
--------N-7F15--CL02-------------------------
INT 7F - Alloy NTNX, MW386 - GET MAXIMUM NUMBER OF CHANNELS
AH = 15h
CL = 02h
Return: AH = number of channels available (40h for MW386)
Note: the application may always assume at least 32 channels available
SeeAlso: AH=15h/CL=03h
--------N-7F15--CL03-------------------------
INT 7F - Alloy NTNX, MW386 - GET MAXIMUM PACKET SIZE
AH = 15h
CL = 03h
DX:DI -> WORD for return value
Return: buffer WORD filled with maximum packet size (4096 for MW386)
SeeAlso: AH=15h/CL=02h
--------N-7F15--CL04-------------------------
INT 7F - Alloy NTNX, MW386 - GET AND CLEAR ACKNOWLEDGE STATUS
AH = 15h
CL = 04h
DX:DI -> status structure (see below)
Return: AL = status
00h successful
DX:DI structure filled
01h busy
0Ah no acknowledgement has arrived
SeeAlso: AH=12h,AH=14h/CL=01h
Format of status structure:
Offset Size Description
00h BYTE sender ID
01h BYTE channel number
02h 4 BYTEs receiver status (see AH=12h)
--------N-7F16-------------------------------
INT 7F - Alloy NTNX, MW386 - DIRECT MEMORY TRANSFER
AH = 16h
DX:SI -> transfer structure (see below)
Return: AL = status
00h successful
0Ah source or destination out of range
0Bh transfer kernal busy--try again
Notes: this call transfers memory contents directly between users; both source
and destination user IDs may differ from the caller's ID
no segment wrap is allowed
Format of transfer structure:
Offset Size Description
00h WORD bytes to transfer
02h BYTE source ID
FEh = caller
03h DWORD source address
07h BYTE destination ID
FFh = all slaves except caller
FEh = caller
08h DWORD destination address
--------N-7F21-------------------------------
INT 7F - Alloy NTNX, MW386 - SEND MESSAGE OR COMMAND TO USER(S)
AH = 21h
AL = sender's user ID
DS:DX -> control packet (see below)
Note: messages or commands are ignored if disabled by the destination user
SeeAlso: AH=22h
Format of control packet:
Offset Size Description
00h BYTE packet type
00h message
01h NTNX command
02h MW386 command
01h BYTE destination user ID or 'A' for all users
02h 62 BYTEs ASCIZ message (packet type 00h)
BIOS keycodes terminated by NUL byte (type 01h) or word (02h)
Note: a maximum of 16 keycodes will be processed for NTNX and MW386 commands
--------N-7F22-------------------------------
INT 7F - Alloy NTNX - GET MESSAGE
AH = 22h
Return: pending messages displayed on user's screen
SeeAlso: AH=21h
--------N-7F24-------------------------------
INT 7F - Alloy NTNX, MW386 - ATTACH OR RELEASE DRIVE FOR LOW-LEVEL WRITE ACCESS
AH = 24h
CL = function
00h attach
01h release
CH = drive (0=A:,1=B:,etc)
Return: AX = status
00h successful
01h invalid request
02h already attached
03h not attached
04h lock table full
Note: only drives on the current machine may be attached
--------N-7F24-------------------------------
INT 7F - Alloy NTNX - ATTACH/RELEASE HOST PROCESSOR
AH = 24h
CL = function
02h attach host
03h release host
Return: AX = status
00h successful
01h invalid request
02h already attached
03h not attached
04h lock table full
Note: the host processor may be attached in order to perform I/O via the host
--------N-7F25--CL00-------------------------
INT 7F - Alloy ANSK, NTNX, MW386 - GET NETWORK EXECUTIVE VERSION
AH = 25h
CL = 00h
Return: AH = version suffix letter
CH = major version number
CL = minor version number
SeeAlso: AH=25h/CL=01h
--------N-7F25--CL01-------------------------
INT 7F - Alloy ANSK, NTNX, MW386 - GET NETWORK EXECUTIVE TYPE
AH = 25h
CL = 01h
Return: CL = type
00h RTNX
01h ATNX
02h NTNX
03h BTNX
04h MW386
05h ANSK
SeeAlso: AH=25h/CL=00h
----------7F2525-----------------------------
INT 7F - TIGA Communications Driver v2.05 - ???
AX = 2525h
BX = ???
Return: ???
SeeAlso: AX=4321h,AX=5555h
--------N-7F26--CL00-------------------------
INT 7F - Alloy NTNX, MW386 - GET NTNX FILE MODE
AH = 26h
CL = 00h
Return: AX = file mode bits (see below)
Note: MW386 does not support file modes, and always returns AX=001Fh
SeeAlso: AH=26h,AH=26h/CL=06h
Bitfields for file mode bits:
bit 0 directory protection enabled
bit 1 extended open enabled
bit 2 flush on every disk write
bit 3 flush on every disk write in locked interval
bit 4 flush on reads from simultaneously opened file
--------N-7F26-------------------------------
INT 7F - Alloy NTNX - SET FILE I/O CHECKING LEVEL
AH = 26h
CL = check type to set/reset
01h directory protection
02h extended open
03h flush on every disk write
04h flush on disk write if any lock set during write
05h flush on all reads if file written
AL = new state (00h off, 01h on)
SeeAlso: AH=26h/CL=00h,AH=26h/CL=06h
--------N-7F26--CL06-------------------------
INT 7F - Alloy NTNX - CANCEL FLUSH ON WRITE
AH = 26h
CL = 06h
Note: cancels flags set by AH=26h/CL=03h and AH=26h/CL=04h
SeeAlso: AH=26h/CL=00h
--------N-7F30-------------------------------
INT 7F - Alloy MW386 - GET PORT INFORMATION
AH = 30h
CX = MW386 port number
Return: AL = FFh if port not found
else driver unit number
BL = port mode
BH = port type
02h remote
DH = owner's machine ID
DL = owner's user ID
SeeAlso: INT 17/AH=8Bh
--------N-7F31-------------------------------
INT 7F - Alloy MW386 v1.x only - CHECK PORT ASSIGNMENT
AH = 31h
???
Return: ???
--------N-7F37-------------------------------
INT 7F - Alloy NTNX (Host) - GET SEMAPHORE TABLE
AH = 37h
Return: ES:AX -> semaphore table
--------N-7F37-------------------------------
INT 7F - Alloy ANSK, NTNX (Slave) - DUMP STRING TO TERMINAL
AH = 37h
DS:DX -> ASCIZ string to display
Note: if the string is empty, a terminal update will be forced
--------N-7F38-------------------------------
INT 7F - Alloy NTNX (Slave), MW386 - SET NEW TERMINAL DRIVER
AH = 38h
AL = new terminal driver number
FFh dummy driver
FEh current driver
FDh load new driver
DS:SI -> new driver
SeeAlso: AH=39h
--------N-7F39-------------------------------
INT 7F - Alloy MW386 - SET TERMINAL DRIVER FOR ANOTHER USER
AH = 39h
AL = new terminal driver number
DL = user number (FFh = caller)
DH = machine number if DL <> FFh
Return: CF set if invalid user number
CF clear if successful
Notes: only available to supervisors
the new driver number will not take effect until the user is rebooted
SeeAlso: AH=38h
--------N-7F3A-------------------------------
INT 7F - Alloy MW386 - GET TERMINAL PARAMETERS
AH = 3Ah
DL = user number (FFh = caller)
DH = machine number
Return: CF clear if successful
AH = terminal driver number
AL = baud rate (00h = 38400, 01h = 19200, etc)
CL = parity (00h none, 01h even, 02h odd)
CH = handshaking (00h none, 01h XON/XOFF, 02h DTR/DSR, 03h XPC)
CF set if invalid user number
SeeAlso: AH=3Bh
--------N-7F3B-------------------------------
INT 7F - Alloy MW386 - SET TERMINAL PARAMETERS
AH = 3Bh
AL = baud rate (00h = 38400, 01h = 19200, etc)
CL = parity (00h none, 01h even, 02h odd)
CH = handshaking (00h none, 01h XON/XOFF, 02h DTR/DSR, 03h XPC)
DL = user number (FFh = caller)
DH = machine number for user
Return: CF set if invalid user number
Notes: only available to supervisors
the new parameters will take effect immediately if the user's terminal
has not been started, else AH=3Dh must be called to post the changes
SeeAlso: AH=3Ah,AH=3Dh
--------N-7F3C-------------------------------
INT 7F - Alloy MW386 - ENABLE/DISABLE AUTOBAUD DETECT
AH = 3Ch
AL = new state
00h disabled, 01h enabled
DL = user number (FFh = caller)
DH = machine number for user
Return: CF set if invalid user number
Note: only available to supervisors
SeeAlso: AH=3Dh
--------N-7F3D-------------------------------
INT 7F - Alloy MW386 - POST TERMINAL CONFIGURATION CHANGES
AH = 3Dh
Note: should be called whenever a program changes the terminal type or its
parameters
SeeAlso: AH=3Bh
--------N-7F41-------------------------------
INT 7F - Alloy NTNX - LOCK FILE FOR USER
AH = 41h
AL = user ID
DS:DX -> ASCIZ filename
Return: AL = status
00h successful
01h invalid function
02h already locked
03h unable to lock
04h lock table full
Note: requests exclusive read/write access to file
SeeAlso: AH=00h,AH=41h"MW386",AH=42h"NTNX"
--------N-7F41-------------------------------
INT 7F - Alloy MW386 - LOCK SEMAPHORE FOR USER
AH = 41h
AL = user ID
DS:DX -> ASCIZ semaphore name
Return: AL = status
00h successful
01h invalid function
02h semaphore already locked
03h unable to lock semaphore
04h semaphore space exhausted
SeeAlso: AH=00h,AH=42h"MW386"
--------N-7F42-------------------------------
INT 7F - Alloy NTNX - UNLOCK FILE FOR USER
AH = 42h
AL = user ID
DS:DX -> ASCIZ filename
Return: AL = status
00h successful
01h invalid function
02h already locked
03h unable to lock
04h lock table full
SeeAlso: AH=00h,AH=41h"NTNX",AH=42h"MW386"
--------N-7F42-------------------------------
INT 7F - Alloy MW386 - UNLOCK SEMAPHORE FOR USER
AH = 42h
AL = user ID
DS:DX -> ASCIZ semaphore name
Return: AL = status
00h successful
01h invalid function
03h unable to unlock semaphore
SeeAlso: AH=02h,AH=41h"MW386",AH=42h"NTNX"
----------7F4321-----------------------------
INT 7F - TIGA Communications Driver v2.05 - INSTALLATION CHECK
AX = 4321h
Return: AX = 0000h if installed
Note: INT 7F is the default, but may be overridden
SeeAlso: AH=01h"TIGA",AX=1234h,AX=2525h,AX=4321h,AX=5555h
--------N-7F4E-------------------------------
INT 7F - Alloy MW386 v2+ - SET ERROR MODE
AH = 4Eh
AL = error mode flags
bit 0: display critical disk errors
bit 1: display sharing errors
DX = 4E58h ("NX")
Return: AL = status
00h successful
SeeAlso: AH=4Fh
--------N-7F4F-------------------------------
INT 7F - Alloy MW386 v2+ - SET FCB MODE
AH = 4Fh
AL = FCB mode
02h read/write compatibility
42h read/write shared
DX = 4E58h ("NX")
Return: AL = status
00h successful
--------V-7F5555-----------------------------
INT 7F - TIGA Communications Driver v2.05 - ???
AX = 5555h
BX = ???
Return: ???
SeeAlso: AX=4321h
--------N-7F81-------------------------------
INT 7F - Alloy NTNX - ATTACH DEVICE FOR USER
AH = 81h
AL = user ID
DS:DX -> ASCIZ device name
SeeAlso: AH=82h
--------N-7F82-------------------------------
INT 7F - Alloy NTNX - RELEASE DEVICE FOR USER
AH = 82h
AL = user ID
DS:DX -> ASCIZ device name
SeeAlso: AH=81h
--------N-7FA0-------------------------------
INT 7F - Alloy MW386 - GET USER NAME
AH = A0h
DL = user number (FFh = caller)
DH = machine number for user
ES:DI -> 17-byte buffer for ASCIZ user name
Return: CF set if invalid user number
SeeAlso: AH=03h,AH=A1h
--------N-7FA1-------------------------------
INT 7F - Alloy MW386 - GET MACHINE, USER, AND PROCESS NUMBER
AH = A1h
Return: AL = process number
DL = user number
DH = machine number
SeeAlso: AH=03h,AH=A0h,AH=A2h
--------N-7FA2-------------------------------
INT 7F - Alloy MW386 - GET USER PRIVILEGE LEVEL
AH = A2h
DL = user number (FFh = caller)
DH = machine number for user
Return: CF clear if successful
AL = privilege level
00h supervisor
01h high
02h medium
03h low
CF set if invalid user number
SeeAlso: AH=A1h,AH=A3h
--------N-7FA3-------------------------------
INT 7F - Alloy MW386 - GET USER LOGIN STATE
AH = A3h
DL = user number
DH = machine number for user
Return: CF clear if successful
AL = login state
00h never logged in
01h currently logged out
03h currently logged in
CF set if invalid user number or user not active
SeeAlso: AH=A2h
--------N-7FA4-------------------------------
INT 7F - Alloy MW386 - VERIFY USER PASSWORD
AH = A4h
DS:DX -> ASCIZ password (null-padded to 16 bytes)
Return: AL = 00h if accepted
else invalid password
--------N-7FA500-----------------------------
INT 7F - Alloy MW386 - GET USER STATUS
AX = A500h
DI = machine number and user number
Return: CF clear if successful
BX = user flags
bit 5: allow messages
CL = scan code for task manager hotkey
CH = scan code for spooler hotkey
DL = scan code for task swapper hotkey
DH = modifier key status
CF set if invalid user number
SeeAlso: AX=A501h
Index: hotkeys;Alloy MW386
--------N-7FA501-----------------------------
INT 7F - Alloy MW386 - SET USER STATUS
AX = A501h
BX = user flags (see above)
CL = scan code for task manager hotkey
CH = scan code for spooler hotkey
DL = scan code for task swapper hotkey
DH = modifier key status
DI = machine number and user number
Return: CF set if invalid user number
Note: must have supervisor privilege to set another user's status
SeeAlso: AX=A500h
Index: hotkeys;Alloy MW386
--------V-7FABCDBX0000-----------------------
INT 7F - IBM 8516 Touch Screen Device Driver - GET API ENTRY
AX = ABCDh
BX = 0000h
Return: AX = total number of functions available
ES:BX -> entry point array
SeeAlso: AX=0104h,AX=0105h
Function numbers:
00h check initialization and reset
14h set user-defined subroutine
Notes: each driver function takes two stack parameters using Pascal calling
conventions: address of parameter block and address of results buffer
all pointers are FAR pointers
on return, AX contains the status of the call:
AX = 0000h successful
0001h invalid input
0002h interface error
0003h unable to perform function
Format of parameter block for function 00h:
Offset Size Description
00h WORD 0000h (function number)
Note: this function should be called before any other device driver functions
Format of results buffer for function 00h:
Offset Size Description
00h WORD touch screen status
0000h unavailable
0001h uncalibrated
FFFFh available
02h WORD aux mouse status (0000h not present, FFFFh present)
Notes: the following driver parameters will have been reset to zero:
touchdown counter, liftoff counter, position at last touch, position
at last lift, int call mask, select on count, select off count,
pos select on count, pos select off count.
the following driver parameters will have been reset as listed:
mouse emulation mode: left on
thresholds: 46 on screen, 96 push harder, 80 push release
x, y hysteresis: 400
data repeat rate: 40/sec
select mechanism: push-harder - first-touch
coordinate origin: upper left corner
filter frequency: medium
data block mask: all enabled
click lock: on
--------N-7FB0-------------------------------
INT 7F - Alloy NTNX, MW386 - RELEASE ALL SEMAPHORES FOR USER
AH = B0h
AL = user number
DS = code segment
Note: MW386 ignores AL and DS; it releases all semaphores locked using INT 67
or INT 7F locking functions
SeeAlso: AH=B1h,AH=B2h,AH=B3h,AH=B4h
--------N-7FB1--SF00-------------------------
INT 7F - Alloy NTNX, MW386 - RELEASE NORMAL SEMAPHORES FOR USER
AH = B1h subfn 00h
AL = (bits 7-5) 000
(bits 4-0) user ID
Note: MW386 ignores AL; it releases all semaphores locked using INT 67 or
INT 7F locking functions
SeeAlso: AH=B0h,AH=B2h,AH=B3h,AH=B4h
--------N-7FB2--SF01-------------------------
INT 7F - Alloy NTNX - RELEASE MESSAGES FOR USER
AH = B2h subfn 01h
AL = (bits 7-5) 001
(bits 4-0) user ID
SeeAlso: AH=B0h,AH=B1h,AH=B3h,AH=B4h
--------N-7FB3--SF02-------------------------
INT 7F - Alloy NTNX - RELEASE FILES FOR USER
AH = B3h subfn 02h
AL = (bits 7-5) 010
(bits 4-0) user ID
SeeAlso: AH=B0h,AH=B1h,AH=B2h,AH=B4h
--------N-7FB4-------------------------------
INT 7F - Alloy NTNX - RELEASE DEVICES FOR USER
AH = B4h
AL = user ID
SeeAlso: AH=B0h,AH=B1h,AH=B2h,AH=B3h
--------N-7FC3-------------------------------
INT 7F - Alloy MW386 - WRITE BYTE TO TERMINAL AUX PORT
AH = C3h
AL = byte to write
Return: CF clear if successful
CF set on error
SeeAlso: AH=C6h
--------N-7FC5-------------------------------
INT 7F - Alloy MW386 - CHANGE CONSOLE MODE
AH = C5h
AL = new console mode
00h keyboard indirect
01h keyboard direct
02h data handshake enforced
03h no data handshake
Return: CF clear if successful
AL = prior console mode
CF set on error (caller is not remote user)
Note: modes 2 and 3 may be used for input through the console port; no video
output should be performed in these modes
--------N-7FC6-------------------------------
INT 7F - Alloy MW386 - WRITE BYTE TO CONSOLE PORT
AH = C6h
AL = byte to write
Return: CF clear if successful
CF set on error (caller is not remote user)
Note: any terminal driver data translation will be bypassed
SeeAlso: AH=C3h,AH=C7h
--------N-7FC7-------------------------------
INT 7F - Alloy MW386 - READ CONSOLE DATA BYTE
AH = C7h
Return: CF clear if successful
AL = byte read
CF set on error (no data available or caller is not remote user)
Note: used to read data after placing console in mode 2 or 3 (see AH=C5h)
SeeAlso: AH=C5h,AH=C6h,AH=C8h
--------N-7FC8-------------------------------
INT 7F - Alloy MW386 - READ CONSOLE DATA INTO BUFFER
AH = C8h
AL = maximum bytes to read
ES:DI -> buffer for console data
Return: CF clear if successful
CX = number of bytes read
CF set on error (caller is not remote user)
SeeAlso: AH=C7h
--------N-7FCF-------------------------------
INT 7F - Alloy NTNX - REBOOT USER PROCESSOR
AH = CFh
DS:DX -> ASCIZ string containing user number to be reset
SeeAlso: AH=D6h
--------N-7FD6-------------------------------
INT 7F - Alloy MW386 - RESET NETWORK EXECUTIVE
AH = D6h
DS:DX -> reset packet (see below)
Return: never if successful
Note: all users will be shut down immediately if successful
SeeAlso: AH=CFh
Format of reset packet:
Offset Size Description
00h DWORD reset code (60606060h)
04h 16 BYTEs ASCIZ supervisor password padded with nulls
--------N-7FD7-------------------------------
INT 7F - Alloy MW386 - POST EVENT
AH = D7h
AL = user number (if local event)
DX = event number
--------N-7FD8-------------------------------
INT 7F - Alloy MW386 - FLUSH DISK BUFFERS
AH = D8h
Return: CF set on error
Note: forces all disk buffers to be written out immediately
SeeAlso: INT 21/AH=0Dh,INT 21/AX=5D01h,INT 2F/AX=1120h
--------N-7FDB-------------------------------
INT 7F - Alloy MW386 v2+ - GET MW386 INVOCATION DRIVE
AH = DBh
Return: AL = drive from which MW386 was started (2=C:,3=D:,etc)
--------N-7FE0-------------------------------
INT 7F - Alloy MW386 - CREATE DOS TASK
AH = E0h
AL = memory size (00h=128K, 01h=256K, 02h=384K, 03h=512K, 04h=640K)
DS:DX -> ASCIZ task name (max 16 bytes)
Return: CF clear if successful
AL = task create ID
CF set on error
Note: only foreground DOS tasks can use this function
SeeAlso: AH=E1h,AH=E2h,AH=E3h,AH=E6h,AH=E7h
--------N-7FE1-------------------------------
INT 7F - Alloy MW386 - GET DOS TASK PID FROM CREATE ID
AH = E1h
AL = create ID (from AH=E0h)
Return: AL = DOS process number
CL = memory size (00h=128K, 01h=256K, 02h=384K, 03h=512K, 04h=640K)
Note: this function should not be called immediately after creating a new
DOS task, since the new task is being initialized by a concurrent
process
SeeAlso: AH=E0h,AH=E2h
--------N-7FE2-------------------------------
INT 7F - Alloy MW386 - SWITCH TO NEW DOS TASK
AH = E2h
AL = DOS process number (from AH=E1h)
Return: CF set on error (invalid process number or caller not foreground task)
Notes: specified task becomes the foreground task and current task is placed
in the background
may only be called by a foreground task
SeeAlso: AH=E0h,AH=E1h
--------N-7FE3-------------------------------
INT 7F - Alloy MW386 - CHANGE NAME OF DOS TASK
AH = E3h
---v1.x---
AL = user number
---v2+---
BH = user number
BL = task number
---
DS:DX -> ASCIZ task name
Return: CF set on error (invalid process number)
SeeAlso: AH=E0h,AH=E4h,AH=E5h
--------N-7FE4-------------------------------
INT 7F - Alloy MW386 - GET TASK NAME FROM PROCESS NUMBER
AH = E4h
---v1.x---
AL = user number
---v2+---
BH = user number
BL = task number
---
ES:DI -> buffer for task name
Return: CF clear if successful
CL = memory size (00h=128K, 01h=256K, 02h=384K, 03h=512K, 04h=640K)
DX = task flags
bit 7: MS-DOS process
ES:DI buffer filled
CF set on error (invalid process number)
SeeAlso: AH=E3h,AH=E5h
--------N-7FE5-------------------------------
INT 7F - Alloy MW386 - GET PROCESS NUMBER FROM TASK NAME
AH = E5h
DS:DX -> ASCIZ task name
BH = user number
Return: CF clear if successful
AL = DOS process number
CL = memory size (00h=128K, 01h=256K, 02h=384K, 03h=512K, 04h=640K)
CF set on error (no match for name)
SeeAlso: AH=E3h,AH=E4h
--------N-7FE6-------------------------------
INT 7F - Alloy MW386 - GET NUMBER OF AVAILABLE USER TASKS
AH = E6h
Return: AX = number of processes available to current user
SeeAlso: AH=E0h
--------N-7FE7-------------------------------
INT 7F - Alloy MW386 - REMOVE DOS TASK
AH = E7h
AL = DOS process number
Return: CF set on error (invalid process number or first process)
Note: can only be called by a foreground task
SeeAlso: AH=E0h
--------N-7FE8-------------------------------
INT 7F - Alloy MW386 - DOS TASK DELAY
AH = E8h
CX = delay time in milliseconds
Note: a delay of 0 may be used to surrender the current time slice
SeeAlso: INT 15/AX=1000h,INT 1A/AX=FF01h,INT 21/AH=EEh"DoubleDOS"
SeeAlso: INT 2F/AX=1680h
--------N-7FF0-------------------------------
INT 7F - Alloy MW386 - RESTRICT DIRECTORY TO GROUP
AH = F0h
AL = group number
DS:DX -> ASCIZ directory name
Return: CF clear if successful
AX = status
0002h directory not found
0003h directory not found
0005h directory in use, cannot be restricted
02xxh restricted to group xxh
CF set on error
Note: the restriction on the directory may be removed by calling this
function with group 0, then using AH=F1h to assign the directory to
group 0
SeeAlso: AH=F1h,AH=F2h,AH=F3h
--------N-7FF1-------------------------------
INT 7F - Alloy MW386 - ASSIGN DIRECTORY TO GROUP
AH = F1h
AL = group number
DS:DX -> ASCIZ directory name
Notes: performs permanent assignment to a group; no immediate action is taken
unless the directory has been restricted with AH=F0h
may be used to restrict a nonexistent directory
SeeAlso: AH=F0h
--------N-7FF2-------------------------------
INT 7F - Alloy MW386 - READ RESTRICTED DIRECTORY ENTRY
AH = F2h
CX = entry number
ES:DI -> 64-byte buffer
Return: CF clear if successful
buffer filled with 63-byte directory info and 1-byte group number
CF set on error (invalid entry)
SeeAlso: AH=F0h,AH=F3h
--------N-7FF3-------------------------------
INT 7F - Alloy MW386 - READ RESTRICTED DIRECTORY ENTRY FOR GROUP
AH = F3h
AL = group number
CX = entry number
ES:DI -> 64-byte buffer
Return: CF clear if successful
CX = next entry number
buffer filled with 63-byte directory info and 1-byte group number
CF set on error (no more matching entries)
Note: like AH=F2h, but only returns directories belonging to the specified
group
SeeAlso: AH=F2h
--------N-7FF8-------------------------------
INT 7F - Alloy MW386 - ASSIGN USER TO GROUP
AH = F8h
AL = group number
DL = user number
DH = machine number (currently 00h)
Return: CF clear if successful
CF set on error (user already in maximum number of groups)
Note: each user is allowed eight group assignments
SeeAlso: AH=F9h,AH=FAh
--------N-7FF9-------------------------------
INT 7F - Alloy MW386 - REMOVE USER FROM GROUP
AH = F9h
AL = group number
DL = user number
DH = machine number (currently 00h)
Return: CF set if failed
SeeAlso: AH=F8h,AH=FAh
--------N-7FFA-------------------------------
INT 7F - Alloy MW386 - GET USER GROUP LIST
AH = FAh
DL = user number
DH = machine number (currently 00h)
ES:DI -> 16-byte buffer for group list
Return: CX = number of groups
ES:DI buffer filled with group numbers
SeeAlso: AH=F8h,AH=F9h
--------N-7FFB-------------------------------
INT 7F - Alloy MW386 - ASSIGN GROUP NAME
AH = FBh
CL = group number
ES:DI -> ASCIZ group name (max 17 bytes)
SeeAlso: AH=FCh
--------N-7FFC-------------------------------
INT 7F - Alloy MW386 - GET GROUP NAME
AH = FCh
CL = group number
ES:DI -> 17-byte buffer for ASCIZ name
Return: ES:DI buffer filled
Note: if the group has not been named, "(unnamed)" is returned
SeeAlso: AH=FBh
----------80---------------------------------
INT 80 - Q-PRO4 - ???
--------r-80---------------------------------
INT 80 - reserved for BASIC
Note: this vector and INT 81 through INT ED are modified but not restored by
Direct Access v4.0, and may be left dangling by other programs
written with the same version of compiled BASIC
SeeAlso: INT 81"BASIC"
--------s-80----BL00-------------------------
INT 80 - SBSIM - "STARTSND" - START SOUND ON SPECIFIED DRIVER
BL = 00h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: AX = initialization result (see below)
Program: SBSIM is Creative Labs' SoundBlaster Simplified Interface Module,
which provides access to multiple drivers for the SoundBlaster
board through a single interface
Note: SBSIM may use any interrupt in the range 80h to BFh; the installation
check consists of testing for the signature "SBSIM" at offset 103h
in the interrupt handler's segment.
SeeAlso: INT 80/BL=01h"SBSIM",INT 80/BL=02h"SBSIM",INT 80/BL=03h"SBSIM"
SeeAlso: INT 80/BX=0000h"SBSIM"
Values for error code:
01h busy--currently in use
02h bad driver specified
03h invalid function
04h voice process already active
05h couldn't start CT-VOICE
06h couldn't start CTVDSK
07h invalid SBSIM handle
08h buffer not initialized yet
09h bad filename
0Ah bad file handle
0Bh driver not started yet
0Ch XMS driver not installed
0Dh no free SBSIM handles
0Eh bad file type
0Fh couldn't free XMS block
10h invalid source selected
11h get pan position failed
12h set pan position failed
13h set volume failed
14h couldn't start fade/pan
15h couldn't stop fade/pan
16h couldn't pause fade/pan
17h not a fade/pan operation
18h bad mode for fade/pan
19h couldn't start fade/pan
1Ah source not fading/panning
1Bh FM or MIDI already playing
1Ch bad MIDI mapper format
--------s-80----BL01-------------------------
INT 80 - SBSIM - "PLAYSND" - PLAY MUSIC/VOICE ON SELECTED DRIVER
BL = 01h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: AX = result
SeeAlso: INT 80/BL=00h"SBSIM",INT 80/BL=02h"SBSIM",INT 80/BL=04h"SBSIM"
--------s-80----BL02-------------------------
INT 80 - SBSIM - "STOPSND" - STOP MUSIC/VOICE ON SELECTED DRIVER
BL = 02h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: nothing
SeeAlso: INT 80/BL=00h"SBSIM",INT 80/BL=01h"SBSIM",INT 80/BL=03h"SBSIM"
--------s-80----BL03-------------------------
INT 80 - SBSIM - "PAUSESND" - TEMPORARILY PAUSE PLAYBACK ON SELECTED DRIVER
BL = 03h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: nothing
SeeAlso: INT 80/BL=00h"SBSIM",INT 80/BL=02h"SBSIM",INT 80/BL=04h"SBSIM"
SeeAlso: INT 80/BL=05h
--------s-80----BL04-------------------------
INT 80 - SBSIM - "RESUMESND" - RESTART PLAYBACK ON SELECTED DRIVER
BL = 04h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: nothing
SeeAlso: INT 80/BL=00h"SBSIM",INT 80/BL=03h"SBSIM",INT 80/BL=05h"SBSIM"
--------s-80----BL05-------------------------
INT 80 - SBSIM - "GETSNDSTAT" - GET DRIVER'S STATUS
BL = 05h
BH = driver number (01h = FM, 02h=DDBV, 03h=memvoice, 05h=MIDI)
Return: AX = status
SeeAlso: INT 80/BL=00h"SBSIM",INT 80/BL=01h"SBSIM",INT 80/BL=03h"SBSIM"
--------s-80----BX0000-----------------------
INT 80 - SoundBlaster SBFM driver - GET VERSION
BX = 0000h
Return: ???
Note: SBFM installs at a free interrupt in the range 80h through BFh
SeeAlso: BX=0008h"SBFM",INT 2F/AX=FBFBh
--------s-80----BX0000-----------------------
INT 80 - SBSIM - "QUERYVERSION" - GET VERSION
BX = 0000h
Return: AX = version (AH = major, AL = minor)
Program: SBSIM is Creative Labs' SoundBlaster Simplified Interface Module,
which provides access to multiple drivers for the SoundBlaster
board through a single interface
Note: SBSIM may use any interrupt in the range 80h to BFh; the installation
check consists of testing for the signature "SBSIM" at offset 103h
in the interrupt handler's segment.
SeeAlso: BX=0001h"SBSIM",BX=0005h"SBSIM",INT 80/BL=00h"SBSIM"
Index: installation check;SBSIM|installation check;SoundBlaster
--------s-80----BX0001-----------------------
INT 80 - SoundBlaster SBFM driver - SET MUSIC STATUS BYTE ADDRESS
BX = 0001h
DX:AX -> music status byte
SeeAlso: BX=0000h"SBFM",BX=0002h"SBFM",BX=0003h"SBFM"
--------s-80----BX0001-----------------------
INT 80 - SBSIM - "QUERYDRIVERS" - CHECK DRIVERS INSTALLED
BX = 0001h
Return: AX = bit flags for loaded drivers (see below)
SeeAlso: BX=0000h"SBSIM",BX=0002h"SBSIM",BX=0005h"SBSIM",INT 80/BL=00h"SBSIM"
Bitfields for loaded drivers:
bit 0 FM
bit 1 double disk-buffered voice driver (DDBV)
bit 2 memory voice driver
bit 3 auxiliary driver (mixer)
bit 4 MIDI
--------s-80----BX0002-----------------------
INT 80 - SoundBlaster SBFM driver - SET INSTRUMENT TABLE
BX = 0002h
CX = number of instruments
DX:AX -> instrument table
SeeAlso: BX=0000h"SBFM",BX=0001h"SBFM",BX=0005h"SBFM"
--------s-80----BX0002-----------------------
INT 80 - SBSIM - GETADDRESS" - GET SELECTED DRIVER'S ENTRY POINT
BX = 0002h
AX = driver (00h = FM,01h = DDBV,02h = memvoice,03h = mixer,04h = MIDI)
Return: CF clear if successful
DX:AX = entry point
CF set on error
SeeAlso: BX=0000h"SBSIM",BX=0001h"SBSIM",BX=0005h"SBSIM",INT 80/BL=00h"SBSIM"
--------s-80----BX0003-----------------------
INT 80 - SoundBlaster SBFM driver - SET SYSTEM CLOCK RATE
BX = 0003h
AX = clock rate divisor (1193180 / desired frequency in Hertz)
FFFFh to restore to 18.2 Hz
SeeAlso: BX=0000h"SBFM",BX=0001h"SBFM",BX=0004h"SBFM"
--------s-80----BX0004-----------------------
INT 80 - SoundBlaster SBFM driver - SET DRIVER CLOCK RATE
BX = 0004h
AX = driver clock rate divisor (1193180 / frequency in Hertz)
Note: default frequency is 96 Hz
SeeAlso: BX=0000h"SBFM",BX=0003h"SBFM"
--------s-80----BX0005-----------------------
INT 80 - SoundBlaster SBFM driver - TRANSPOSE MUSIC
BX = 0005h
AX = semi-tone offset
SeeAlso: BX=0000h"SBFM",BX=0002h"SBFM",BX=0006h"SBFM"
--------s-80----BX0005-----------------------
INT 80 - SBSIM - "GETBUFFERINFO" - GET DRIVER'S BUFFER ADDRESS
BX = 0005h
AX = driver (00h = FM, 01h = DDB Voice, 04h = MIDI)
Return: CF clear if successful
DX:AX -> buffer
CX = buffer size in K
CF set on error
Program: SBSIM is Creative Labs' SoundBlaster Simplified Interface Module,
which provides access to multiple drivers for the SoundBlaster
board through a single interface
Note: SBSIM may use any interrupt in the range 80h to BFh; the installation
check consists of testing for the signature "SBSIM" at offset 103h
in the interrupt handler's segment.
SeeAlso: BX=0000h"SBSIM",BX=0001h"SBSIM",BX=0002h"SBSIM",INT 80/BL=00h"SBSIM"
--------s-80----BX0006-----------------------
INT 80 - SoundBlaster SBFM driver - PLAY MUSIC
BX = 0006h
DX:AX -> music block
Return: AX = status
0000h successful
0001h music already active
SeeAlso: BX=0000h"SBFM",BX=0007h"SBFM",BX=000Ah"SBFM",INT 1A/AX=FF04h
--------s-80----BX0007-----------------------
INT 80 - SoundBlaster SBFM driver - STOP MUSIC
BX = 0007h
Return: AX = status
0000h successful
0001h music not active
SeeAlso: BX=0000h"SBFM",BX=0006h"SBFM",BX=0009h"SBFM",INT 1A/AX=FF05h
--------s-80----BX0008-----------------------
INT 80 - SoundBlaster SBFM driver - RESET DRIVER
BX = 0008h
Return: AX = status
0000h successful
0001h music is active
SeeAlso: BX=0000h"SBFM"
--------s-80----BX0009-----------------------
INT 80 - SoundBlaster SBFM driver - PAUSE MUSIC
BX = 0009h
Return: AX = status
0000h successful
0001h no music active
SeeAlso: BX=0000h"SBFM",BX=0007h"SBFM",BX=000Ah"SBFM",INT 1A/AX=FF01h
--------s-80----BX000A-----------------------
INT 80 - SoundBlaster SBFM driver - RESUME MUSIC
BX = 000Ah
Return: AX = status
0000h successful
0001h no music paused
SeeAlso: BX=0000h"SBFM",BX=0006h"SBFM",BX=0009h"SBFM"
--------s-80----BX000B-----------------------
INT 80 - SoundBlaster SBFM driver - SET USER-DEF TRAP FOR SYSTEM-EXCLUSIVE CMDS
BX = 000Bh
DX:AX -> trap routine
SeeAlso: BX=0000h"SBFM"
--------s-80----BX0400-----------------------
INT 80 - SBSIM - "GETVOLUME" - GET SOURCE'S VOLUME
BX = 0400h
AX = sound source (see below)
Return: CF clear if successful
AX = volume
CF set on error
AX = error code (see INT 80/BL=00h)
SeeAlso: BX=0401h"SBSIM"
Values for sound source:
00h master volume
01h voice
02h FM
03h CD
04h line in
05h microphone
--------s-80----BX0401-----------------------
INT 80 - SBSIM - "SETVOLUME" - SET SOURCE'S VOLUME
BX = 0401h
AX = sound source (see INT 80/BX=0400h)
DX = new volume
Return: AX = result (0000h = success) (see also INT 80/BL=00h)
SeeAlso: BX=0400h"SBSIM"
--------N-8001-------------------------------
INT 80 - QPC Software PKTINT.COM - INITIALIZE
AH = 01h
Return: AX = 0000h
CX = FFFFh
DX = FFFFh
Notes: this interrupt is the WinQVTNet protected mode interface to Windows 3.0
all buffer pointers are reset back to 0
--------N-8002-------------------------------
INT 80 - QPC Software PKTINT.COM - GET BUFFER ADDRESSES
AH = 02h
BX = extra bytes to allocate per packet
Return: AX = segment address of 10K buffer (for receives???)
BX = segment address of 2K buffer (for sends???)
SeeAlso: AH=05h
--------N-8003-------------------------------
INT 80 - QPC Software PKTINT.COM - GET ENTRY POINT
AH = 03h
Return: CX:DX -> receive call address
Note: the returned address can be used in the packet driver calls since it
will be a valid address in all DOS boxes
SeeAlso: AH=06h
--------N-8004-------------------------------
INT 80 - QPC Software PKTINT.COM - ENABLE???
AH = 04h
BX = ???
Return: ???
SeeAlso: AH=01h
--------N-8005-------------------------------
INT 80 - QPC Software PKTINT.COM - GET RECEIVE STATISTICS
AH = 05h
Return: AX = amount of buffer currently in use
BX = current offset in buffer
CX = number of times receive has been called
SeeAlso: AH=02h
--------N-8006-------------------------------
INT 80 - QPC Software PKTINT.COM - REMOVE RECEIVED PACKET
AH = 06h
Return: BX = next packet offset
CX = number of bytes still buffered
DX = size of packet released back into buffer pool
SeeAlso: AH=03h
--------r-81---------------------------------
INT 81 - reserved for BASIC
Note: this vector is modified but not restored by Direct Access v4.0, and
may be left dangling by other programs written with the same version
of compiled BASIC
SeeAlso: INT 80"BASIC",INT 82"BASIC"
--------N-81---------------------------------
INT 81 - IBM TOKEN RING ADAPTER - ???
SeeAlso: INT 82"TOKEN RING",INT 91"TOKEN RING"
--------r-82---------------------------------
INT 82 - reserved for BASIC
SeeAlso: INT 81"BASIC",INT 83"BASIC"
--------N-82---------------------------------
INT 82 - IBM TOKEN RING ADAPTER - ???
AH = function
00h display message???
DS:BX -> string
???
Return: ???
SeeAlso: INT 81"TOKEN RING",INT 91"TOKEN RING"
--------r-83---------------------------------
INT 83 - reserved for BASIC
SeeAlso: INT 82"BASIC",INT 84"BASIC"
--------r-84---------------------------------
INT 84 - reserved for BASIC
SeeAlso: INT 83"BASIC",INT 85"BASIC"
--------r-85---------------------------------
INT 85 - reserved for BASIC
Note: INT 80 through INT ED are modified but not restored by Direct Access
v4.0, and may be left dangling by other programs written with the
same version of compiled BASIC
SeeAlso: INT 84"BASIC",INT 86"BASIC"
--------N-86---------------------------------
INT 86 - NetBIOS - ORIGINAL INT 18
Note: some implementations of NetBIOS reportedly relocate INT 18 here
SeeAlso: INT 18
--------r-86---------------------------------
INT 86 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 85"BASIC",INT 87"BASIC"
--------r-86---------------------------------
INT 86 - APL*PLUS/PC - Terminate APL session and return to DOS
SeeAlso: INT 21/AH=4Ch,INT 87"APL"
--------r-87---------------------------------
INT 87 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 86"BASIC",INT 88"BASIC"
--------r-87---------------------------------
INT 87 - APL*PLUS/PC - ???
SeeAlso: INT 86"APL",INT 88/AL=00h
--------v-87---------------------------------
INT 87 - VIRUS - "ZeroHunt" - VIRAL CODE (NOT A VECTOR!)
Note: the ZeroHunt virus copies its resident code down to 0000h:021Ch and
following
SeeAlso: INT 8B"VIRUS"
--------r-88---------------------------------
INT 88 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 87"BASIC",INT 89"BASIC"
--------r-88--00-----------------------------
INT 88 - APL*PLUS/PC - CREATE OBJECT OF ARBITRARY RANK OR SHAPE
AL = 00h
BX = STPTR of the variable to be assigned
ES:SI -> model of type, rank, and shape (see below)
Return: ES:DI -> first data byte of object
DX:CX = number of elements in the object
SeeAlso: INT C8"APL"
Format of shape model:
Offset Size Description
00h BYTE type
01h character (2-byte dimension sizes)
02h integer (2-byte dimension sizes)
08h floating point (2-byte dimension sizes)
11h character (4-byte dimension sizes)
12h integer (4-byte dimension sizes)
18h floating point (4-byte dimension sizes)
01h BYTE rank
02h WORD/DWORD first dimension of shape
N WORD/DWORD second dimension of shape
...
--------r-88--01-----------------------------
INT 88 - APL*PLUS/PC - CREATE CHARACTER SCALAR/VECTOR/MATRIX <64K IN SIZE
AL = 01h
AH = rank
BX = STPTR of the variable to be assigned
CX = first dimension (if any)
DX = second dimension (if any)
Return: ES:DI -> object
CX = number of elements in the object
Note: each dimension must be 32767 or smaller
SeeAlso: AL=02h,AL=08h,INT C8"APL"
--------r-88--02-----------------------------
INT 88 - APL*PLUS/PC - CREATE INTEGER SCALAR/VECTOR/MATRIX <64K IN SIZE
AL = 02h
AH = rank
BX = STPTR of the variable to be assigned
CX = first dimension (if any)
DX = second dimension (if any)
Return: ES:DI -> object
CX = number of elements in the object
Note: each dimension must be 32767 or smaller
SeeAlso: AL=01h,AL=08h,INT C8"APL"
--------r-88--08-----------------------------
INT 88 - APL*PLUS/PC - CREATE FLOATING POINT SCALAR/VECTOR/MATRIX <64K IN SIZE
AL = 08h
AH = rank
BX = STPTR of the variable to be assigned
CX = first dimension (if any)
DX = second dimension (if any)
Return: ES:DI -> object
CX = number of elements in the object
Note: each dimension must be 32767 or smaller
SeeAlso: AL=01h,AL=02h,INT C8"APL"
--------r-88--F5-----------------------------
INT 88 - APL*PLUS/PC - FORCE OBJECT INTO REAL WORKSPACE FROM VIRTUAL
AL = F5h
BX = STPTR of object
SeeAlso: INT C8"APL"
--------r-88--F6-----------------------------
INT 88 - APL*PLUS/PC - MAKE NAME IMMUNE FROM OUTSWAPPING
AL = F6h
BX = STPTR of object
SeeAlso: AL=F7h,AL=F8h,INT C8"APL"
--------r-88--F7-----------------------------
INT 88 - APL*PLUS/PC - MAKE NAME ELIGIBLE FOR OUTSWAPPING
AL = F7h
BX = STPTR of object
SeeAlso: AL=F6h,AL=F8h,INT C8"APL"
--------r-88--F8-----------------------------
INT 88 - APL*PLUS/PC - REPORT WHETHER NAME IS ELIGIBLE FOR OUTSWAPPING
AL = F8h
BX = STPTR of object
Return: BX = name's status
0000h eligible
0001h not eligible
SeeAlso: AL=F6h,AL=F7h,INT C8"APL"
--------r-88--F9-----------------------------
INT 88 - APL*PLUS/PC - DETERMINE NAME STATUS
AL = F9h
ES:SI -> name
CX = length of name
Return: CF set if name ill-formed or already in use
BX = STPTR if already in symbol table
CF clear if name is available for use
BX = 0000h
Note: does not force the name into the workspace
SeeAlso: AL=FEh,AL=FFh,INT C8"APL"
--------r-88--FC-----------------------------
INT 88 - APL*PLUS/PC - DETERMINE IF MEMORY AVAIL WITHOUT GARBAGE COLLECTION
AL = FCh
BX = amount of memory needed (paragraphs)
Return: CF clear if memory available
CF set if a workspace compaction is required
SeeAlso: AL=FDh,INT C8"APL"
--------r-88--FD-----------------------------
INT 88 - APL*PLUS/PC - PERFORM GARBAGE COLLECTION AND RETURN AVAILABLE MEMORY
AL = FDh
Return: BX = number of paragraphs available in workspace
SeeAlso: AL=FCh,INT C8"APL"
--------r-88--FE-----------------------------
INT 88 - APL*PLUS/PC - CREATE NAME
AL = FEh
ES:SI -> name
CX = length of name
Return: BX = STPTR of name
DX = interpreter's data segment
SeeAlso: AL=F9h,AL=FFh,INT C8"APL"
--------r-88--FF-----------------------------
INT 88 - APL*PLUS/PC - DETERMINE NAME STATUS
AL = FFh
ES:SI -> name
CX = length of name
Return: CF set if name ill-formed or already in use
BX = STPTR if already in symbol table
CF clear if name is available for use
BX = 0000h
Note: forces the name into the workspace and makes it immune from outswapping
SeeAlso: AL=F9h,AL=FEh,INT C8"APL"
--------r-89---------------------------------
INT 89 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 88"BASIC",INT 8A"BASIC"
--------r-8A---------------------------------
INT 8A - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 89"BASIC",INT 8B"BASIC"
--------r-8A---------------------------------
INT 8A - APL*PLUS/PC - PRINT SCREEN
Note: same as INT 05
SeeAlso: INT 05,INT 8C"APL",INT CA"APL"
--------r-8B---------------------------------
INT 8B - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT 8A"BASIC",INT 8C"BASIC"
--------r-8B---------------------------------
INT 8B - APL*PLUS/PC - BEEP
Note: same as printing a ^G via INT 21/AH=02h
SeeAlso: INT 21/AH=02h,INT CB"APL"
--------v-8B---------------------------------
INT 8B - VIRUS - "ZeroHunt" - INSTALLATION CHECK (NOT A VECTOR!)
Note: if the ZeroHunt virus is resident, this vector will contain either
EE83h:019Bh (ZH-411) or EE83h:019Fh (ZH-415)
SeeAlso: INT 70"VIRUS",INT 87"VIRUS",INT 9C"VIRUS"
--------r-8C---------------------------------
INT 8C - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-8C---------------------------------
INT 8C - APL*PLUS/PC - CLEAR SCREEN MEMORY
AX = flag
0000h do not save display attributes
0001h save attributes
SeeAlso: INT CC"APL"
--------r-8D---------------------------------
INT 8D - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-8E---------------------------------
INT 8E - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-8F---------------------------------
INT 8F - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-90---------------------------------
INT 90 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-90---------------------------------
INT 90 - APL*PLUS/PC - USED BY PORT 10 PRINTER DRIVER
--------r-91---------------------------------
INT 91 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-91---------------------------------
INT 91 - IBM TOKEN RING ADAPTER - ???
SeeAlso: INT 81"TOKEN RING",INT 82"TOKEN RING",INT 93"TOKEN RING"
--------r-92---------------------------------
INT 92 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-92---------------------------------
INT 92 - Sangoma X.25 INTERFACE PROGRAM
BX:DX -> control block
SeeAlso: INT 68"Sangoma"
--------e-92E1-------------------------------
INT 92 - Da Vinci eMail Dispatcher INTERFACE
AH = E1h
AL = function
BX = stack count (number of words to push)
CX:DX -> stack data (in word-reversed order ready to push)
Return: AX = status (see below)
Note: preserves BP, DS, SI, DI; other registers may be destroyed
Values for status:
0001h success
FF97h "ERS_NOT_AVAILABLE"
FF99h "ERS_TOO_MANY_NAMES"
FF9Ah "ERS_BAD_NAME_PASSWORD"
FFE3h "ERS_NAME_NOT_FOUND"
FFF8h "ERS_USE_STRING" (call NetGetError to get error string)
FFFFh "ERS_NO_SUCH_FILE"
--------e-92E100-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetInitStart"
AX = E100h
BX = size of parameter block in words (000Ah)
CX:DX -> parameter block (see below)
Return: AX = 0001h success
Desc: this function is used to initialize the dispatcher
SeeAlso: AX=E101h,AX=E103h
Format of parameter block:
Offset Size Description
00h WORD segment of ???
02h WORD offset of ???
04h WORD high part of long ???
06h WORD low part of long ???
08h WORD high part of long ???
0Ah WORD low part of long ???
0Ch WORD high part of long ???
0Eh WORD low part of long ???
10h WORD high part of long ???
12h WORD low part of long ???
--------e-92E101BX0000-----------------------
INT 92 - Da Vinci eMail Dispatcher - "NetInitCheck"
AX = E101h
BX = 0000h
CX:DX ignored
Return: AX = 0001h success
SeeAlso: AX=E100h,AX=E180h
--------e-92E102BX0000-----------------------
INT 92 - Da Vinci eMail Dispatcher - "NetCheckDriver"
AX = E102h
BX = 0000h
CX:DX ignored
Return: AX = 0001h success
Desc: this function is used to determine if the dispatcher is loaded
SeeAlso: AX=E10Bh,AX=E180h
--------e-92E103BX0000-----------------------
INT 92 - Da Vinci eMail Dispatcher - "NetTerminate"
AX = E103h
BX = 0000h
CX:DX ignored
Return: AX = status (see AH=E1h)
SeeAlso: AX=E100h
--------e-92E104-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetWhereIs"
AX = E104h
BX = size of parameter block in words (0006h)
CX:DX -> parameter block (see below)
Return: AX = status (see AH=E1h)
Desc: this function is used to verify node address for usernames
SeeAlso: AX=E180h
Format of parameter block:
Offset Size Description
00h WORD segment of node address buffer
02h WORD offset of node address buffer
04h WORD segment of uppercase username
06h WORD offset of uppercase username
08h WORD segment of "DVSEMAIL"
0Ah WORD offset of "DVSEMAIL"
--------e-92E105-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetOpen"
AX = E105h
BX = size of parameter block in words (0007h)
CX:DX -> parameter block (see below)
Return: AX = 0000h Error
AX = handle
Desc: this function is used to open a submission channel
SeeAlso: AX=E10Ah,AX=E106h,AX=E108h
Format of parameter block:
Offset Size Description
00h WORD operation (1 = read, 2 = write)
02h WORD segment of uppercase To: username
04h WORD offset of uppercase To: username
06h WORD segment of "DVSEMAIL"
08h WORD offset of "DVSEMAIL"
0Ah WORD segment of node address
0Ch WORD offset of node address
--------e-92E106BX0004-----------------------
INT 92 - Da Vinci eMail Dispatcher - "NetRead"
AX = E106h
BX = 0004h
CX:DX -> parameter block
Return: AX = 0001h
SeeAlso: AX=E108h
--------e-92E107BX0002-----------------------
INT 92 - Da Vinci eMail Dispatcher - "NetGetError"
AX = E107h
BX = 0002h
CX:DX -> parameter block
Return: AX = 0001h
SeeAlso: AX=E109h,AX=E180h
--------e-92E108-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetWrite"
AX = E108h
BX = size of parameter block in words (0004h)
CX:DX -> parameter block (see below)
Return: AX = amount written
Desc: This function is used to write transactions to the dispatcher.
The command block is written first and then another call is used
to write the associated data.
SeeAlso: AX=E106h
Format of parameter block:
Offset Size Description
00h WORD buffer count
02h WORD segment of command buffer
04h WORD offset of command buffer
06h WORD handle from NetOpen
Format of command buffer:
Offset Size Description
00h BYTE command
21h '!' Protocol commands for remote control
41h 'A' Authorization protocol element
42h 'B' Return(back) routing information
Associated data is the From: username
43h 'C' Carbon Copy list
Associated data is a comma delimitted list of usernames
44h 'D' Distribution list
Associated data is a comma delimitted list of usernames
45h 'E' Mail end marker
No associated data
48h 'H' Mail message header
Associated data is a message header buffer
4Dh 'M' Mail message
Associated data is the body of the message
4Fh 'O' Object
50h 'P' Paperclip attachment
52h 'R' Routing information
Associated data is the To: username
53h 'S' Subject
Associated data is the subject of the message
54h 'T' Trail of Reply/Forwards
01h BYTE subcommand
02h DWORD length of associated data
Format of message header buffer:
Offset Size Description
00h 30 BYTEs subject line
1Eh 24 BYTEs To
36h 24 BYTEs From
4Eh DWORD Time
BYTE 00h
BYTE hour
BYTE minute
BYTE second
52h DWORD Date
BYTE 00h
BYTE year
BYTE month
BYTE day
56h DWORD serial number (00000000h)
5Ah WORD mail types (see below)
5Ch WORD special types (0)
Bitfields for mail types:
bit 7 blind carbon copy
bit 6 carbon copy
bit 5 priority
bit 4 confidential
bit 3 certified
bit 2 bulk
bits 1-0 class (first, second, third, bulk)
--------e-92E109-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetErrorFix" (UNUSED)
AX = E109h
BX = size of parameter block in words (0001h)
CX:DX -> parameter block (see below)
Return: AX = FF97h (ERS_NOT_AVAILABLE)
SeeAlso: AX=E107h,AX=E180h
Format of parameter block:
Offset Size Description
00h WORD ???
--------e-92E10A-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetClose"
AX = E10Ah
BX = size of parameter block in words (0001h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
Desc: this function is used to close a dispatcher handle
SeeAlso: AX=E105h
Format of parameter block:
Offset Size Description
00h WORD handle from NetOpen
--------e-92E10B-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetCheckQueue"
AX = E10Bh
BX = size of parameter block in words (0004h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E102h,AX=E10Ch
Format of parameter block:
Offset Size Description
00h WORD segment of 24-byte username buffer
02h WORD offset of 24-byte username buffer
04h WORD segment of 24-byte protocol buffer
06h WORD offset of 24-byte protocol buffer
--------e-92E10C-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetReadQueue"
AX = E10Ch
BX = size of parameter block in words (0002h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E10Bh
Format of parameter block:
Offset Size Description
00h WORD Segment of 128 byte node address buffer
02h WORD Offset of 128 byte node address buffer
--------e-92E10D-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetSubmitName"
AX = E10Dh
BX = size of parameter block in words (0006h)
CX:DX -> parameter block (see below)
Return: AX = status (see AH=E1h)
Desc: this function is used to verify username/password
SeeAlso: AX=E10Eh
Format of parameter block:
Offset Size Description
00h WORD segment of uppercase password string
02h WORD offset of uppercase password string
04h WORD segment of uppercase username string
06h WORD offset of uppercase username string
08h WORD segment of "DVSEMAIL"
0Ah WORD offset of "DVSEMAIL"
--------e-92E10E-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetRemoveName"
AX = E10Eh
BX = size of parameter block in words (0004h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
Desc: this function is used to remove a username
SeeAlso: AX=E10Dh
Format of parameter block:
Offset Type Description
00h WORD segment of uppercase username
02h WORD offset of uppercase username
04h WORD segment of "DVSEMAIL"
06h WORD offset of "DVSEMAIL"
--------e-92E10FBX0000-----------------------
INT 92 - Da Vinci eMail Dispatcher - IS ANYONE THERE? QUERY
AX = E10Fh
BX = 0000h
CX:DX ignored
Return: AX = 0001h
SeeAlso: AX=E180h
--------e-92E110-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetGetAltRoute"
AX = E110h
BX = size of parameter block in words (0006h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E111h,AX=E113h
Format of parameter block:
Offset Size Description
00h 6 WORDs ???
--------e-92E111-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetDeleteAltRoutes"
AX = E111h
BX = size of parameter block in words (0004h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E110h,AX=E113h
Format of parameter block:
Offset Size Description
00h 4 WORDs ???
--------e-92E112-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetChangePassword"
AX = E112h
BX = size of parameter block in words (0008h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E180h
Format of parameter block:
Offset Size Description
00h 8 WORDs ???
--------e-92E113-----------------------------
INT 92 - Da Vinci eMail Dispatcher - "NetSetAltRoute"
AX = E113h
BX = size of parameter block in words (0008h)
CX:DX -> parameter block (see below)
Return: AX = 0001h
SeeAlso: AX=E110h,AX=E111h
Format of parameter block:
Offset Size Description
00h 8 WORDs ???
--------e-92E175-----------------------------
INT 92 - Da Vinci eMail Dispatcher - BECOME MICRO TSR
AX = E175h
Return: AX = 0012h
BX = PSP
SeeAlso: AX=E180h
--------e-92E180-----------------------------
INT 92 - Da Vinci eMail Dispatcher - INSTALLATION CHECK
AX = E180h
Return: AX = 0012h if installed
ES:DX -> '$'-terminated driver information string
SeeAlso: AX=E102h,AX=E105h,AX=E10Fh,AX=E175h
--------r-93---------------------------------
INT 93 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-93---------------------------------
INT 93 - IBM TOKEN RING ADAPTER - ???
SeeAlso: INT 81"TOKEN RING",INT 91"TOKEN RING"
--------r-94---------------------------------
INT 94 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------s-94----SI0000-----------------------
INT 94 u - PCM driver - INITIALIZE SOUND
SI = 0000h
ES:BX -> parameters
Return: ???
Program: PCM.COM is a sound driver for Media Vision's Pro Audio Spectrum
sound boards
Note: the installation check consists of testing for the signature string
"PCMDRIVER" immediately preceding the interrupt handler; the word
preceding the signature gives the PCM driver's version
SeeAlso: SI=0001h,SI=0002h,SI=0003h,SI=0004h,SI=0005h,SI=000Ah
Index: installation check;PCM driver|PCM.COM;installation check
Index: PCM driver;installation check
--------s-94----SI0001-----------------------
INT 94 u - PCM driver - INITIALIZE PCM
SI = 0001h
ES:BX -> parameters
Return: ???
SeeAlso: SI=0000h,SI=0002h,SI=0003h,SI=000Ah
--------s-94----SI0002-----------------------
INT 94 u - PCM driver - INITIALIZE PCM INFO
SI = 0002h
ES:BX -> parameters (see below)
Return: ???
SeeAlso: SI=0000h,SI=0001h,SI=0003h,SI=000Ah
Format of parameters:
Offset Size Description
00h DWORD rate
04h WORD channel number
06h WORD "comp"
08h WORD "dsize"
--------s-94----SI0003-----------------------
INT 94 u - PCM driver - INITIALIZE DMA BUFFER
SI = 0003h
ES:BX -> parameters (see below)
Return: ???
SeeAlso: SI=0000h,SI=000Ah,SI=000Bh
Format of parameters:
Offset Size Description
00h DWORD -> DMA buffer
04h WORD size of DMA buffer
06h WORD number of divisions
--------s-94----SI0004-----------------------
INT 94 u - PCM driver - INITIALIZE USER FUNCTION
SI = 0004h
ES:BX -> parameters (see below)
Return: ???
SeeAlso: SI=0000h,SI=0001h
Format of parameters:
Offset Size Description
00h DWORD -> user function
--------s-94----SI0005-----------------------
INT 94 u - PCM driver - BEGIN AUDIO PLAY
SI = 0005h
Return: ???
SeeAlso: SI=0000h,SI=0006h,SI=0007h,SI=0009h
--------s-94----SI0006-----------------------
INT 94 u - PCM driver - BEGIN AUDIO RECORD
SI = 0006h
Return: ???
SeeAlso: SI=0005h,SI=0007h,SI=0009h
--------s-94----SI0007-----------------------
INT 94 u - PCM driver - PAUSE AUDIO PLAY/RECORD
SI = 0007h
Return: ???
SeeAlso: SI=0005h,SI=0006h,SI=0008h
--------s-94----SI0008-----------------------
INT 94 u - PCM driver - RESUME AUDIO PLAY/RECORD
SI = 0008h
Return: ???
SeeAlso: SI=0007h
--------s-94----SI0009-----------------------
INT 94 u - PCM driver - STOP AUDIO PLAY/RECORD
SI = 0009h
Return: ???
SeeAlso: SI=0005h,SI=0006h,SI=0007h
--------s-94----SI000A-----------------------
INT 94 u - PCM driver - UNHOOK INTERRUPTS AND TURN OFF DMA
SI = 000Ah
Return: ???
SeeAlso: SI=0000h,SI=0001h,SI=0003h
Index: uninstall;PCM driver
--------s-94----SI000B-----------------------
INT 94 u - PCM driver - FIND VALID DMA BUFFER IN HUGE MEMORY BLOCK
SI = 000Bh
ES:BX -> parameters (see below)
Return: ???
SeeAlso: SI=0003h
Format of parameters:
Offset Size Description
00h DWORD -> memory block to contain DMA buffer
04h WORD desired size of DMA buffer
--------s-94----SI000D-----------------------
INT 94 u - Media Vision PCM.COM - GET STATUS
SI = 000Dh
Return: AX = status (0000h = waiting) (see below)
Bitfields for status:
bit 0 playing
bit 1 recording
bit 2 SBplaying
bit 3 SBrecording
bit 14 SBpaused
bit 15 paused
--------s-94----SI8000-----------------------
INT 94 u - Media Vision PCM.COM - GET INTERNAL DMA BUFFER ADDRESS
SI = 8000h
Return: DX:AX -> DMA buffer
Program: PCM.COM is a superset of the standard PCM driver which provides
additional functions for fine control of the driver
Note: the installation check for the Media Vision PCM.COM "shark" functions
consists of testing for the signature "PCM-SHARK" at offset 107h in
the INT 94 handler's segment
SeeAlso: SI=8001h,SI=8004h
Index: installation check;Media Vision PCM.COM|PCM.COM;installation check
Index: Media Vision PCM.COM;"shark" functions
--------s-94----SI8001-----------------------
INT 94 u - Media Vision PCM.COM - GET INTERNAL DMA BUFFER SIZE AND DIVISIONS
SI = 8001h
Return: AX = DMA buffer size
DX = divisions
SeeAlso: SI=8000h
--------s-94----SI8002-----------------------
INT 94 u - Media Vision PCM.COM - CHECK BOARD ADDRESS
SI = 8002h
Return: AX = status
0000h if board not at specified I/O address
other if board found
Note: the I/O address is specified by ORing the base I/O port shifted left
four bits into SI before calling INT 94
SeeAlso: SI=8000h
--------s-94----SI8004-----------------------
INT 94 u - Media Vision PCM.COM - GET INTERNAL NOTE BUFFER
SI = 8004h
Return: AX = offset of note buffer (segment = segment of internal DMA buffer)
DX = size of buffer in note structures
SeeAlso: SI=8000h
--------s-94----SI8005-----------------------
INT 94 u - Media Vision PCM.COM - SINGLE-STEP QUEUE
SI = 8005h
Return: ???
--------s-94----SI8011-----------------------
INT 94 u - Media Vision PCM.COM - INITIALIZE
SI = 8011h
ES:BX -> "iobf91" structure
Return: ???
--------s-94----SI8012-----------------------
INT 94 u - Media Vision PCM.COM - LOAD SOUND FOR LATER PLAY THROUGH KEYBOARD
SI = 8012h
ES:BX -> "i94f92buf" structure
Return: ???
SeeAlso: SI=8013h,SI=8014h
--------s-94----SI8013-----------------------
INT 94 u - Media Vision PCM.COM - GET INTERNAL SOUND USAGE
SI = 8013h
Return: AX = number of sounds used
DX = maximum handles
--------s-94----SI8014-----------------------
INT 94 u - Media Vision PCM.COM - GET DATA FOR SPECIFIED SOUND
SI = 8014h
ES:BX -> "i94f92buf" structure to be filled in
sound number field set to desired sound
Return: AX = status
0000h successful
FFFFh sound number out of range
SeeAlso: SI=8012h,SI=8013h
--------s-94----SI8015-----------------------
INT 94 u - Media Vision PCM.COM - GET/SET INTERNAL DMA BUFFER
SI = 8015h
ES:BX -> DMA info structure (see below)
Return: ???
Format of DMA info structure:
Offset Size Description
00h DWORD -> DMA buffer (offset FFFFh = return current buffer info)
04h WORD DMA buffer size
06h WORD divisions
--------s-94----SI8016-----------------------
INT 94 u - Media Vision PCM.COM - SIMULATE DOUBLE-SHIFT HOTKEY
SI = 8016h
AX = hotkey number (01h-08h)
Return: ???
SeeAlso: AL=02h/SI=8017h
--------s-94--01SI8017-----------------------
INT 94 u - Media Vision PCM.COM - CTRL-G INTERCEPT
AL = 01h
SI = 8017h
AH = new state (00h off, 01h on)
Return: ???
SeeAlso: AL=02h/SI=8017h
--------s-94--02SI8017-----------------------
INT 94 u - Media Vision PCM.COM - DOUBLE-SHIFT-HOTKEY SOUND FEATURE
AL = 02h
SI = 8017h
AH = new state (00h off, 01h on)
Return: ???
--------s-94--04SI8017-----------------------
INT 94 u - Media Vision PCM.COM - RANDOM SOUND FEATURE
AL = 04h
SI = 8017h
AH = new state
00h off
01h on
CX = minimum delay
DX = maximum delay
Return: ???
--------s-94--08SI8017-----------------------
INT 94 u - Media Vision PCM.COM - NO ACTIVITY FEATURE
AL = 08h
SI = 8017h
AH = new state
00h off
01h on
DX:CX = delay
Return: ???
SeeAlso: AL=10h/SI=8017h
--------s-94--10SI8017-----------------------
INT 94 u - Media Vision PCM.COM - TIMER CONTROL
AL = 10h
SI = 8017h
AH bit 7: set timer
AH bit 6: timer active (timer turned off if clear)
AH bits 5-0: timer number
DX:CX = delay if AH bit 7 set (one-shot if DX bit 15 set)
Return: ???
SeeAlso: AL=08h/SI=8017h
--------s-94----SI8018-----------------------
INT 94 u - Media Vision PCM.COM - GET INFO
SI = 8018h
AL = what to get
00h "F92state"
01h "F92bkgd"
02h "I10timer"
03h "I08state"
Return: DX:AX -> desired information
--------r-95---------------------------------
INT 95 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-95---------------------------------
INT 95 - APL*PLUS/PC - DETERMINE R= SPACE
Note: use only when the R= option is invoked on entering APL
--------r-96---------------------------------
INT 96 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-97---------------------------------
INT 97 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-98---------------------------------
INT 98 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-99---------------------------------
INT 99 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-9A---------------------------------
INT 9A - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-9B---------------------------------
INT 9B - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-9C---------------------------------
INT 9C - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------v-9C---------------------------------
INT 9C - VIRUS - "INT13" - ORIGINAL INT 13h VECTOR
SeeAlso: INT 8B"VIRUS",INT 9D"VIRUS",INT 9E"VIRUS",INT 9F"VIRUS"
--------r-9D---------------------------------
INT 9D - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------v-9D---------------------------------
INT 9D - VIRUS - "INT13" - ROM INT 13h ENTRY POINT
Note: this vector is used by the virus to store the result of a call to
INT 2F/AH=13h
SeeAlso: INT 2F/AH=13h,INT 9C"VIRUS",INT 9E"VIRUS",INT 9F"VIRUS"
--------r-9E---------------------------------
INT 9E - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------v-9E---------------------------------
INT 9E - VIRUS - "INT13" - ORIGINAL INT 21h VECTOR
SeeAlso: INT 70"VIRUS",INT 9C"VIRUS",INT 9D"VIRUS",INT E0"VIRUS"
--------r-9F---------------------------------
INT 9F - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------v-9F---------------------------------
INT 9F - VIRUS - "INT13" - STORAGE FOR USER INT 13h VECTOR
Note: while it is infecting a file, the INT13 virus grabs INT 13 and uses
this interrupt to store the existing INT 13 vector for later
restoration
SeeAlso: INT 9C"VIRUS",INT 9D"VIRUS"
--------r-A0---------------------------------
INT A0 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A0---------------------------------
INT A0 - APL*PLUS/PC - USED BY APL/GSS*CGI GRAPHICS INTERFACE
SeeAlso: INT 59
--------r-A1---------------------------------
INT A1 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A2---------------------------------
INT A2 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A3---------------------------------
INT A3 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A4---------------------------------
INT A4 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------U-A4---------------------------------
INT A4 U - Right Hand Man - API
AH = function number (v3.3 supports functions 00h-52h)
Return: CF set on error
CF clear if successful
Program: Right Hand Man is a TSR desk-top utility originally by Red E Products
which has evolved into Futurus Team
Note: this interrupt is only hooked while popped up
SeeAlso: INT 2F/AX=A4E0h
--------r-A5---------------------------------
INT A5 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A6---------------------------------
INT A6 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A7---------------------------------
INT A7 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A8---------------------------------
INT A8 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-A9---------------------------------
INT A9 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AA---------------------------------
INT AA - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AB---------------------------------
INT AB - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AC---------------------------------
INT AC - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AD---------------------------------
INT AD - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AE---------------------------------
INT AE - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-AF---------------------------------
INT AF - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B0---------------------------------
INT B0 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B1---------------------------------
INT B1 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B2---------------------------------
INT B2 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B3---------------------------------
INT B3 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------U-B370-------------------------------
INT B3 - ZIPKEY - GET VERSION
AH = 70h
Return: AH = major version
AL = minor version
CL = number of states and territories in current database
DH = year of current database - 1900
DL = month of current database's file date
Program: ZIPKEY is a resident ZIPCODE database by Eric Isaacson
Note: if installed, the string "ZIPKEY" is present at offset 75h in the
interrupt handler's segment, and the byte at 7Bh contains the API
version number (00h for v1.x, 01h for v2.0)
--------U-B371-------------------------------
INT B3 - ZIPKEY - CONVERT TWO-LETTER ABBREVIATION TO STATE CODE
AH = 71h
BX = abbreviation, in either case (first letter in BL)
Return: CF set on error
AL = FFh
CF clear if successful
AL = ZIPKEY state code
SeeAlso: AH=72h
--------U-B372-------------------------------
INT B3 - ZIPKEY - CONVERT STATE CODE TO TWO-LETTER ABBREVIATION
AH = 72h
BL = ZIPKEY state code
Return: CF set on error
AX destroyed
CF clear if successful
AX = abbreviation, in upper case
SeeAlso: AH=71h,AH=73h
--------U-B373-------------------------------
INT B3 - ZIPKEY - CONVERT STATE CODE TO STATE NAME
AH = 73h
BL = ZIPKEY state code
ES:DI -> buffer for name
Return: CF set on error
AX destroyed
CF clear if successful
ES:DI points one byte beyond end of name
SeeAlso: AH=72h
--------U-B374-------------------------------
INT B3 - ZIPKEY - CONVERT ZIPCODE TO ASCII DIGITS
AH = 74h
DX = zipcode region (0-999)
CH = last two digits of zipcode (0-99)
ES:DI -> buffer
Return: CF set on error
AX destroyed
CF clear if successful
ES:DI points one byte beyond end of digit string
--------U-B375-------------------------------
INT B3 - ZIPKEY - LOOK UP STATE CODE FOR ZIPCODE
AH = 75h
DX = zipcode region (0-999)
CH = last two digits of zipcode (0-99)
Return: CF set on error (zipcode not found)
AL = suggested state code, FFh if none
CF clear if successful
AL = ZIPKEY state code
BX = area code (v2.0+)
SeeAlso: AH=76h,AH=79h
--------U-B376-------------------------------
INT B3 - ZIPKEY - LOOK UP CITY AND STATE FOR ZIPCODE
AH = 76h
DX = zipcode region (0-999)
CH = last two digits of zipcode (0-99)
ES:DI -> buffer for name
Return: CF set on error
AL = suggested state code, FFh if none
ES:DI buffer filled with suggested city name
CF clear if successful
AL = ZIPKEY state code
BX = area code (v2.0+)
ES:DI points one byte beyond end of name
SeeAlso: AH=75h,AH=78h,AH=7Eh
--------U-B377-------------------------------
INT B3 - ZIPKEY - PLAY BACK EXIT KEY FOR ENTRY WITH GIVEN ZIPCODE
AH = 77h
DX = zipcode region (0-999)
CH = last two digits of zipcode (0-99)
BX = 16-bit BIOS keycode for a defined ZIPKEY alternate exit key
Return: CF set on error
AX destroyed
CF clear if successful
zipcode specification as defined by the BX keystroke is placed in
keyboard buffer, as if the user had popped up ZIPKEY and exited
by pressing the key specified by BX
--------U-B378-------------------------------
INT B3 - ZIPKEY - LOOK UP ZIPCODES FOR A GIVEN STATE AND CITY
AH = 78h
BL = ZIPKEY state code
DS:SI -> city name, terminated with 0Dh if complete name, 00h if prefix
Return: BH = number of matching entries (set to 51 if more than 50)
DX = zipcode region of first match (0-999)
CL = last two digits of first zipcode in the range (0-99)
CH = last two digits of last zipcode in the range (0-99)
AX destroyed
SeeAlso: AH=79h,AH=7Ah
--------U-B379-------------------------------
INT B3 - ZIPKEY - LOOK UP ZIPCODES FOR A GIVEN CITY
AH = 79h
BL = ZIPKEY state code of first state to search
DS:SI -> city name, terminated with 0Dh if complete name, 00h if prefix
Return: AL = ZIPKEY state code of first matching state
BH = number of matching entries (set to 51 if more than 50)
DX = zipcode region of first match (0-999)
CL = last two digits of first zipcode in first range (0-99)
CH = last two digits of last zipcode in first range (0-99)
Note: to find all matching cities, repeat search with BL set to one more than
the returned AL
SeeAlso: AH=78h,AH=7Ah
--------U-B37A-------------------------------
INT B3 - ZIPKEY - FETCH AN ENTRY FROM A PREVIOUS LOOKUP
AH = 7Ah
BL = case number (0 to one less than value returned in BH by lookup)
Return: AL = ZIPKEY state code
DX = zipcode region (0-999)
CL = last two digits of first zipcode in the range (0-99)
CH = last two digits of last zipcode in the range (0-99)
SeeAlso: AH=78h,AH=79h
--------U-B37B-------------------------------
INT B3 - ZIPKEY - GET VALUES NEEDED TO SAVE ZIPKEY CONTEXT
AH = 7Bh
Return: BL = maximum number of characters for a city name
BH = ZIPKEY state code for last city-name search
FFh if none
CX:DX = internal code identifying last city search
AX destroyed
SeeAlso: AH=7Ch
--------U-B37C-------------------------------
INT B3 - ZIPKEY - RESTORE ZIPKEY CONTEXT
AH = 7Ch
BL = maximum number of characters for a city name
BH = ZIPKEY state code for last city-name search
FFh if none
CX:DX = internal code returned by AH=7Bh
Return: CF set on error
CF clear if successful
AX destroyed
SeeAlso: AH=7Bh
--------U-B37D-------------------------------
INT B3 - ZIPKEY - REQUEST POP UP
AH = 7Dh
BL = index number to simulate pressing a hotkey
FFh for immediate popup with no playback on return
Return: CF set on error
AL = FDh already busy with another request
= FEh illegal function
CF clear if successful
AX destroyed
window popped up and was closed by the user
SeeAlso: AH=70h
--------U-B37E-------------------------------
INT B3 - ZIPKEY - GET NAME OF PRIMARY CITY FOR A ZIPCODE REGION
AH = 7Eh
DX = zipcode region (0-999)
ES:DI -> buffer for name
Return: CF set on error
AL = FFh region does not exist
CF clear if successful
AL = ZIPKEY state code
ES:DI points one byte beyond end of name
SeeAlso: AH=76h
--------U-B37F-------------------------------
INT B3 - ZIPKEY - ENABLE/DISABLE HOTKEYS
AH = 7Fh
BL = function
00h turn off hotkeys
01h turn on hotkeys
02h return hotkey status
03h toggle hotkey status
Return: AL = hotkey status
00h off
01h on
--------U-B380-------------------------------
INT B3 - ZIPKEY v2.0+ - DETERMINE STATE FOR AREA CODE
AH = 80h
BX = telephone area code (decimal)
Return: CF clear if successful
AL = ZIPKEY state code
DX = first ZIP region for state (03E8h if Canada)
CX = number of ZIP regions in state
CF set on error
AL = FFh
DX = 03E9h
--------r-B4---------------------------------
INT B4 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B4---------------------------------
INT B4 - StackMan - REQUEST NEW STACK
Return: SS:SP -> new stack
Program: StackMan is a freeware stack manager by Franz Veldman of ESaSS B.V.
which functions as a replacement for the DOS STACK= command as well
as permitting multiple TSRs to share a pool of stack space
Note: the installation check consists of testing for the string "STACKXXX" at
offset 0Ah from the interrupt handler
SeeAlso: INT 2F/AX=C9FFh,INT B5"STACKMAN"
Index: installation check;STACKMAN
--------r-B5---------------------------------
INT B5 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B5---------------------------------
INT B5 - StackMan - RESTORE ORIGINAL STACK
SS:SP -> stack returned by INT B4
Return: SS:SP restored to value before INT B4
SeeAlso: INT 2F/AX=C9FFh,INT B4"StackMan"
--------m-B5---------------------------------
INT B5 U - Netroom NETSWAP4 - ???
???
Return: ???
SeeAlso: INT 31/AH=57h
--------r-B6---------------------------------
INT B6 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------y-B6---------------------------------
INT B6 - (NOT A VECTOR!) - USED BY TBFENCE
Program: TBFence is a security program by ESaSS B.V. which transparently
encrypts floppies and optionally allows only encrypted diskettes to
be accessed
Note: the low word of this vector (0000h:02D8h) contains the segment of the
TBFence INT 13h code, which starts with the signature word E487h;
this forms the installation check
the highest byte of this vector contains the start of a FAR JMP
instruction to ???
SeeAlso: INT B7"TBFENCE"
Index: installation check;TBFence
--------r-B7---------------------------------
INT B7 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------y-B7---------------------------------
INT B7 - TBFENCE - ???
SeeAlso: INT B6"TBFENCE"
--------r-B8---------------------------------
INT B8 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-B9---------------------------------
INT B9 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-BA---------------------------------
INT BA - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-BB---------------------------------
INT BB - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-BC---------------------------------
INT BC - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-BD---------------------------------
INT BD - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-BE---------------------------------
INT BE - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------Q-BE---------------------------------
INT BE - DESQview/X - ???
Note: points at an IRET
SeeAlso: INT 15/AX=BFDEh/BX=0006h,INT 63"DESQview"
--------r-BF---------------------------------
INT BF - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C0---------------------------------
INT C0 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C1---------------------------------
INT C1 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C2---------------------------------
INT C2 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C3---------------------------------
INT C3 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C4---------------------------------
INT C4 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C5---------------------------------
INT C5 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C6---------------------------------
INT C6 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C6---------------------------------
INT C6 - APL*PLUS/PC - IDENTICAL TO INT 86
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 86"APL"
--------r-C7---------------------------------
INT C7 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C7---------------------------------
INT C7 - APL*PLUS/PC - ???
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 87"APL"
--------r-C8---------------------------------
INT C8 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C8---------------------------------
INT C8 - APL*PLUS/PC - IDENTICAL TO INT 88
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 88"APL"
--------r-C9---------------------------------
INT C9 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-C9---------------------------------
INT C9 - APL*PLUS/PC - ???
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 89"APL"
--------r-CA---------------------------------
INT CA - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CA---------------------------------
INT CA - APL*PLUS/PC - PRINT SCREEN
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 8A"APL"
--------r-CB---------------------------------
INT CB - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CB---------------------------------
INT CB - APL*PLUS/PC - BEEP
Notes: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
same as printing a ^G via INT 21/AH=02h
SeeAlso: INT 8B"APL"
--------r-CC---------------------------------
INT CC - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CC---------------------------------
INT CC - APL*PLUS/PC - CLEAR SCREEN MEMORY
AX = flag
0000h do not save display attributes
0001h save attributes
Note: STSC moved its interrupts from 86h-8Ch to C6h-CCh, but did not delete
the older interrupts
SeeAlso: INT 8C"APL"
--------r-CD---------------------------------
INT CD - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CD---------------------------------
INT CD - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-CE---------------------------------
INT CE - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CE---------------------------------
INT CE - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-CF---------------------------------
INT CF - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-CF---------------------------------
INT CF - APL*PLUS/PC - DEFAULT LOW-RESOLUTION TIMER FOR QUAD MF FUNCTION
SeeAlso: INT E0"APL"
--------r-D0---------------------------------
INT D0 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D0---------------------------------
INT D0 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------U-D0---------------------------------
INT D0 - [not a vector!] - NJFRERAM SIGNATURE VECTOR
Program: NJFRERAM is a resident free-memory display utility by Mike "Nifty
James" Blaszczak
Note: if NJFRERAM is installed, this vector points at the signature "NJ"
Index: installation check;NJFRERAM
--------r-D1---------------------------------
INT D1 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D1---------------------------------
INT D1 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D2---------------------------------
INT D2 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D2---------------------------------
INT D2 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D3---------------------------------
INT D3 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D3---------------------------------
INT D3 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D4---------------------------------
INT D4 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D4---------------------------------
INT D4 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------O-D400-------------------------------
INT D4 O - PC-MOS/386 v5.01 - OBSOLETE FUNCTIONS
AH = 00h and 01h
Return: nothing
Desc: PC-MOS/386 v5.01 reports that these functions are no longer supported
and enters an endless loop
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
--------O-D402-------------------------------
INT D4 - PC-MOS/386 v3.0+ - GET SYSTEM CONTROL BLOCK POINTER
AH = 02h
Return: AX = 0000h
ES:BX -> System Control Block in V86 mode (see below)
ES:EBX -> System Control Block in native mode (see below)
Note: superseded by AH=26h
SeeAlso: AH=04h,AH=10h,AH=26h,AH=28h,AH=29h,AH=2Ah,INT 21/AX=3000h,INT 38
Format of System Control Block:
Offset Size Description
00h WORD pointer to first TCB in chain
02h 17 BYTEs reserved
13h WORD pointer to current task's TCB
15h WORD pointer to TCB of visible (console) task
--------O-D403-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET/SET EXTENDED DIRECTORY INFORMATION
AH = 03h
AL = subfunction (00h get, 01h set)
DS:(E)DX -> pathname
ES:(E)BX -> 10-byte buffer for directory information (see below)
Return: CF clear if successful
AL = permitted access level for file (00h-03h)
ES:(E)BX -> modified buffer (AL=01h on entry)
CF set on error
AX = error code (see INT 21/AH=59h)
Notes: BX/DX are used in V86 mode, EBX/EDX in native mode
the file class cannot be changed for files because it affects the
encryption method, but directories can have their classes changed
Format of directory information:
Offset Size Description
00h BYTE reserved (0)
01h BYTE file class ('A'-'Z' or 00h)
02h DWORD user ID of file creator
06h WORD file creation time (see INT 21/AX=5700h)
08h WORD file creation date (see INT 21/AX=5700h)
--------O-D404-------------------------------
INT D4 - PC-MOS/386 v3.0+ - GET TASK CONTROL BLOCK
AH = 04h
BX = task ID or FFFFh for calling task
Return: CF clear if successful
ES = segment of Task Control Block (TCB) (see below)
CF set on error
AX = error code (see INT 21/AH=59h)
Note: superseded by AH=27h
SeeAlso: AH=02h,AH=27h,AH=28h,AH=29h,AH=2Ah,INT 38
Format of Task Control Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "T" = TCB
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---TCB---
10h WORD TCB task ID
12h WORD native context save area
14h WORD start address of task
16h WORD end address of task
18h BYTE task priority
19h BYTE task time slice
1Ah BYTE "TCBWAIT" run status of task
1Bh BYTE "TCBSTAT" what the task is waiting for
1Ch DWORD address of polling routine
20h BYTE error code from last function call
21h 11 BYTEs name of currently executing task
2Ch 4 BYTEs ???
30h BYTE keyboard disabled if bit 1 set
31h BYTE current shift state and toggles
32h 2 BYTEs ???
34h BYTE current video mode
35h BYTE current video page
36h BYTE number of text columns per screen
37h BYTE number of text rows per screen
38h WORD length of video buffer
3Ah WORD video page length
3Ch WORD apge start address in video RAM
3Eh 4 WORDs current cursor positions for four screen pages
46h 8 BYTEs ???
4Eh WORD current cursor type
50h BYTE current palette setting
51h BYTE original video mode
52h BYTE start CRT row (00h or 01h)
53h BYTE video RAM in task active
54h WORD handle of video save area
56h WORD page count of video save area
58h WORD segment address of video save area
5Ah WORD poitner to first Task File Block (see below)
5Ch WORD pointer to first Current Directory Block (see below)
5Eh WORD pointer to active Current Directory Block (see below)
60h BYTE number of drives
61h BYTE current drive (0=A:, etc.)
62h DWORD disk transfer address
66h 4 BYTEs ???
6Ah BYTE verify flag (nonzero = on)
6Bh BYTE break flag (nonzero = on)
6Ch WORD share/lock retry count
6Eh WORD ticks between share/lock retries
70h BYTE remote printer flags (see below)
71h BYTE ETX/ACK delay count
72h WORD spooler segment address
74h 2 BYTEs ???
76h 3 BYTEs remote printer redirection for LPT1 through LPT3 (see below)
79h 2 BYTEs ???
7Bh DWORD offset of username in TCB
7Fh BYTE current output class
80h 7 BYTEs protection access rights, 2 bits per class (writeable!)
87h 122 BYTEs ???
101h BYTE TCB sleep downcounter value
102h 20 BYTEs ???
116h BYTE last scan code
...
5D0h DWORD far pointer to Device Driver Terminal's entry point
5D4h WORD offset of logical screen
5D6h WORD segment of logical screen
5D8h WORD cursor offset within page
5DAh BYTE screen columns
5DBh WORD async port number (0000h = none)
5DDh DWORD physical baudrate
5E1h 19 BYTEs reserved for Device Driver Terminal (DDT)
...
7A6h DWORD far pointer to unregister calling chain
Bitfield for remote printer flags:
bit 0 LPT1 to terminal
bit 1 LPT2 to terminal
bit 2 LPT3 to terminal
bit 3 escape to printer pending
bit 4 use XON/XOFF
bit 5 use ETX/ACK
bit 6 waiting for ACK or XON
bit 7 transparent printing on
Values for remote printer redirection:
00h not redirected
01h redirected to COM1
...
18h redirected to COM24
51h redirected to LPT1
52h redirected to LPT2
53h redirected to LPT3
Format of Task File Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "F" = task file block
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---TFB---
10h WORD segment address of next TFB
12h WORD segment address of previous TFB
14h WORD segment address of TFB's Global File Block (see below)
16h WORD segment address of owner's PSP
18h WORD file handle
1Ah 3 BYTEs ???
1Dh DWORD file position
21h 4 BYTEs ???
25h BYTE IOCTL flags (see below)
26h 2 BYTEs ???
Bitfields for IOCTL flags:
bit 0 stdin
bit 1 stdout
bit 2 null device
bit 3 clock device
bit 4 reserved
bit 5 ASCII mode instead of binary
bit 6 EOF encountered on input
bit 7 device rather than file
Format of Global File Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "G" = global file block
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---GFB---
10h 10 BYTEs ???
1Ah WORD file attribute
1Ch BYTE ???
1Dh DWORD address of device driver
21h WORD first cluster
23h WORD time of last modification
25h WORD date of last modification
27h DWORD size of file in bytes
2Bh 11 BYTEs ???
36h 11 BYTEs device name or FCB-format filename
41h WORD segment address of TFB list
43h WORD segment address of first RLB (see below) (0000h = none)
45h BYTE flag: nonzero if GFB refers to character device
46h WORD address of Block Device Block (see below)
48h WORD sector of file's directory entry
4Ah WORD high word of file's directory entry
4Ch WORD ofsset of directory entry within sector
Format of Current Directory Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "C" = current directory block
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---CDB---
10h BYTE drive number
11h BYTE ???
12h 64 BYTEs directory name
52h WORD first directory cluster (0000h = root)
Format of Block Device Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "B" = block device block
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---BDB---
10h BYTE logical drive
11h BYTE unit passed to driver
12h WORD sector size
14h BYTE cluster mask
15h BYTE cluster shift count
16h WORD starting sector of first FAT
18h BYTE number of FATs
19h WORD number of root directories
1Bh WORD sector number of first data sector (cluster 0002h)
1Dh WORD number of clusters + 1 (number of highest data cluster)
1Fh BYTE number of sectors in FAT
20h WORD beginning root directory sector number
22h DWORD device driver address
26h BYTE media descriptor byte
27h 5 BYTEs ???
2Ch BYTE flag: volume > 32MB
2Dh BYTE ???
2Eh BYTE number of sectors per cluster
2Fh WORD number of clusters on device
31h WORD number of free clusters (FFFFh = unknown)
33h WORD root directory cluster number
35h WORD pointer to alias/subst string
37h WORD TCB segment address of owner (0000h = none)
Format of Record Lock Block:
Offset Size Description
00h BYTE signature byte "H" if allocated from system memory pool
01h BYTE header block ID, "R" = record lock block
02h WORD length of block in paragraphs
04h WORD segment address of next header block (0000h if last)
06h WORD segment address of previous header block (0000h if first)
08h WORD pointer to next TCB
0Ah WORD pointer to previous TCB
0Ch WORD pointer to associated TCB (if applicable)
0Eh WORD reserved
---RLB---
10h WORD segment address of owner's PSP
12h WORD segment address of Global File Block (see above)
14h WORD segment address of owner's Task File Block (see above)
16h DWORD file offset of locked region start
1Ah DWORD length of locked region
1Eh WORD owner's handle for file
--------O-D407-------------------------------
INT D4 - PC-MOS/386 v3.0+ - WAIT FOR EVENT
AH = 07h
AL = events to monitor (see below)
BX = number of timer ticks until timeout if AL bit 1 set
CX = bitmap of IRQs to monitor if AL bit 2 set
(bit 0 = IRQ0 .. bit 15 = IRQ15)
DX = port to monitor if AL bit 3 set
Return: CF clear if successful
AL = type of event which woke up task (see above)
CX = IRQ (if any) which awakened task
DX = port (if any) which awakened task
CF set on error
AX = error code (see INT 21/AH=59h)
Note: a device driver may make this call with AL=00h, which indicates that
the driver is responsible for setting and clearing the TCBWAIT field
in the TCB. To put task to sleep, set TCBWAIT bits 2-0 to 001; to
reawaken it, set bit 1 (leaving other bits unchanged)
SeeAlso: AH=04h,INT 16/AH=00h,INT 38
Bitfields for events to monitor:
bit 0 keystroke
bit 1 timeout
bit 2 IRQ
bit 3 port access
bit 7 return status of user poll routine (other bits ignored if set)
--------O-D410-------------------------------
INT D4 - PC-MOS/386 v3.0+ - ENTER/LEAVE NATIVE 386 EXECUTION MODE
AH = 10h
AL = direction (00h return to V86 mode, 01h enter native mode)
CX = length in bytes of Native Context Area ( >=1024 )
DX = segment of Native Context Area
Return: CF clear if successful
running in desired mode at instruction following INT D4 call
all segment registers converted to appropriate selectors/segments
CF set on error
AX = error code (see INT 21/AH=59h)
Note: MS-DOS calls are available in protected mode
SeeAlso: AH=11h,AH=12h,AH=13h,INT 2F/AX=1687h,INT 67/AX=DE0Ch,INT 38
--------O-D411-------------------------------
INT D4 - PC-MOS/386 v3.0+ - ALLOCATE NATIVE MODE MEMORY BLOCK
AH = 11h
EBX = block length in bytes
Return: CF clear if successful
EBX = number of bytes actually allocated
ES = selector for allocated block
CF set on error
AX = error code (see INT 21/AH=59h)
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
Note: memory must be released before program terminates
SeeAlso: AH=10h,AH=12h,INT 38
--------O-D412-------------------------------
INT D4 - PC-MOS/386 v3.0+ - FREE NATIVE MODE MEMORY BLOCK
AH = 12h
ES = selector for block to free
Return: CF clear if successful
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=10h,AH=11h,AH=13h,INT 38
--------O-D413-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET ALIAS FOR SELECTOR (NATIVE MODE ONLY)
AH = 13h
AL = type of alias selector (00h data, 01h stack, 02h code)
BX = selector
Return: CF clear if successful
AX = new selector or 0000h if BX selector not found
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=11h,AH=12h
--------O-D416-------------------------------
INT D4 - PC-MOS/386 v5.01 - SET/CLEAR IRQ RESERVATION
AH = 16h
AL = function (00h clear, 01h set reservation)
CX = IRQ number
Return: AX = status
(0000h successful, 0001h currently reserved by another task)
SeeAlso: AH=07h,INT 14/AH=11h"PC-MOS"
--------O-D419-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET TASK ID
AH = 19h
Return: BX = caller's task ID
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: AH=1Dh,AH=1Eh
--------O-D41A-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET/SET TASK PRIORITY
AH = 1Ah
AL = subfunction (00h read, 01h set, 02h get and set)
BX = task ID (FFFFh for current task)
CL = new priority value
Return: CF clear if successful
CL = current priority value
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=1Bh,AH=1Ch
--------O-D41B-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET/SET TIME SLICE
AH = 1Bh
AL = subfunction (00h read, 01h set, 02h get and set)
BX = task ID (FFFFh for current task) (see AH=19h)
CL = new time slice value
Return: CF clear if successful
CL = current time slice value
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=1Ah,AH=1Ch
--------O-D41C-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET/SET KEYBOARD MODE
AH = 1Ch
AL = subfunction (00h enable, 01h disable, 02h get mode)
BX = task ID (FFFFh for current task)
Return: CF clear if successful
CL = current keyboard state
CF set on error
AX = error code (INT 21/AH=59h)
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: AH=1Ah,AH=1Bh
--------O-D41D-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET CURRENT PROGRAM NAME
AH = 1Dh
BX = task ID (FFFFh for current task) (see AH=19h)
ES:DI -> buffer for program name (see below)
Return: CF clear if successful
ES:DI buffer filled
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=19h,AH=1Eh
Format of buffer:
Offset Size Description
00h 8 BYTEs filename
08h 3 BYTEs extension
--------O-D41E-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET CURRENT USERNAME AND SECURITY CLASS
AH = 1Eh
BX = task ID (FFFFh for current task)
ES:DI -> 4-byte buffer for username
Return: CF clear if successful
CL = security class
20h (' ') none
41h-5Ah ('A'-'Z') security level
ES:DI buffer filled
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=19h,AH=1Dh
--------O-D41F-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET TASK PARTITION INFORMATION
AH = 1Fh
BX = task ID (FFFFh for current task) (see AH=19h)
Return: CF clear if successful
CX = start segment of task
DX = ending segment of task
CF set on error
AX = error code (see INT 21/AH=59h)
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: AH=2Dh
--------O-D420-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET PORT AND BAUDRATE INFORMATION
AH = 20h
BX = task ID (FFFFh for current task) (see AH=19h)
Return: CF clear if successful
CX = port number (0000h if none)
DI:SI = baudrate (if CX nonzero)
CF set on error
AX = error code (see INT 21/AH=59h)
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: INT 14/AH=0Ch"FOSSIL"
--------O-D421-------------------------------
INT D4 - PC-MOS/386 v5.01 - REMOVE A TASK
AH = 21h
BX = task ID (FFFFh for current task) (see AH=19h)
Return: CF clear if successful
AX = ASCII percentage of System Memory Pool used
(AH = tens digit, AL = ones digit)
DS,SI destroyed
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=22h
--------O-D422-------------------------------
INT D4 - PC-MOS/386 v5.01 - ADD A TASK TO THE SYSTEM
AH = 22h
DS:SI -> addtask data structure (see below)
Return: CF clear if successful
ES = segment address of the new task's TCB data structure
CF set on error
AX = error code (see below)
SeeAlso: AH=21h
Values for error code:
08h insufficient memory
0Bh invalid addtask structure format
12h insufficient available space in system memory pool
1Fh general failure
55h already allocated
57h if task already in use or invalid parameter
Format of addtask data structure:
Offset Size Description
00h WORD task size in KB (min 16KB)
02h WORD task ID (0000h for automatic selection)
04h BYTE task class (' ' or 'A'-'Z')
05h DWORD -> ASCIZ name of task startup batchfile
09h DWORD -> task's terminal driver (0000000h = background task)
0Dh WORD task port
0Fh DWORD task baud rate
13h DWORD (return) total extended memory
17h DWORD (return) number of 4K extended memory pages allocated
1Bh WORD (return) paragraphs of system memory pool allocated
1Dh WORD (return) system memory pool size in paragraphs
1Fh WORD (return) ASCII task percentage of system memory pool
21h 3 BYTEs reserved
--------O-D423-------------------------------
INT D4 - PC-MOS/386 v5.01 - CHANGE TERMINAL DRIVER
AH = 23h
BX = task ID (FFFFh for current task)
DS:SI -> entry point of the new Device Driver Terminal
Return: CF clear if successful
CF set on error
AX = error code (see INT 21/AH=59h)
--------O-D424-------------------------------
INT D4 U - PC-MOS/386 v5.01 - GET OPERATING SYSTEM SERIAL NUMBER
AH = 24h
Return: DS:DX -> '$'-terminated string containing the serial number
--------O-D425-------------------------------
INT D4 - PC-MOS/386 v5.01 - IDENTIFY LOAD ADDRESS OF DEVICE DRIVER LOCATION
AH = 25h
DX = driver's CS value
Return: AX = segment address of driver in system memory pool
(0000h if the driver is not within the system memory pool)
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
--------O-D426-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET SYSTEM CONTROL BLOCK SEGMENT/SELECTOR
AH = 26h
Return: DX = segment/selector of the System Control Block (see AH=02h)
Note: this function supersedes AH=02h
SeeAlso: AH=02h,AH=27h,AH=28h,AH=29h,AH=2Ah
--------O-D427-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET TASK CONTROL BLOCK SEGMENT/SELECTOR
AH = 27h
BX = task ID (FFFFh if current task) (see AH=19h)
Return: CF clear if successful
DX = segment/selector for the Task Control Block (see AH=04h)
CF set on error
AX = error code (INT 21/AH=59h)
Note: this function supersedes AH=04h
SeeAlso: AH=26h,AH=28h,AH=29h,AH=2Ah
--------O-D428-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET CONTROL BLOCK DATA FROM SCB OR TCB
AH = 28h
BX = offset into control block at which to start reading
CX = number of bytes to read
DX = segment/selector of control block obtained via AH=26h or AH=27h
ES:DI -> buffer for data
Return: CF clear if successful
CF set on error
AX = error code (see also INT 21/AH=59h)
05h access denied due to an invalid segment/selector
SeeAlso: AH=26h,AH=27h,AH=29h,AH=2Ah
--------O-D429-------------------------------
INT D4 - PC-MOS/386 v5.01 - WRITE CONTROL BLOCK DATA INTO SCB OR TCB
AH = 29h
BX = offset into control block at which to start writing
CX = number of bytes to write
DX = segment/selector of control block obtained via AH=26h or AH=27h
DS:SI -> buffer containing data to be written
Return: CF clear if successful
CF set on errro
AX = error code (see also INT 21/AH=59h)
05h access denied due to an invalid segment/selector
Note: this function performs no bounds checking
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: AH=26h,AH=27h,AH=28h,AH=2Ah
--------O-D42A-------------------------------
INT D4 - PC-MOS/386 v5.01 - SWAP CONTROL BLOCK DATA OF SCB OR TCB
AH = 2Ah
BX = offset into control block at which to start swap
CX = number of bytes to swap
DX = segment/selector of control block obtained via AH=26h or AH=27h
DS:SI -> buffer containing new data and to receive current data
Return: CF clear if successful
CF set on error
AX = error code (see also INT 21/AH=59h)
05h access denied due to an invalid segment/selector
Note: the interrupts are disabled during the swap to prevent corruption
SeeAlso: AH=26h,AH=27h,AH=28h,AH=29h
--------O-D42C-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET/SET SPOOLER PARAMETERS
AH = 2Ch
AL = function
00h set spooler timeout
CX = timout value in seconds
01h get spooler timeout
Return: CX = current timeout in seconds
02h get spooler parameters
Return: CH = priority (00h-09h)
CL = disposition (d, h, i, n, s)
SI = class (a - z)
03h set spooler parameters
CH = priority (00h-09h)
CL = disposition (d, h, i, n, s)
SI = class (a - z)
BX = task ID (FFFFh for current task)
DX = LPT number
Return: CF clear if successful
CF set on error
AX = error code (see INT 21/AH=59h)
SeeAlso: AH=00h,AH=02h,AH=03h
--------O-D42D-------------------------------
INT D4 - PC-MOS/386 v5.01 - GET MAXIMUM TASK SIZE
AH = 2Dh
Return: DX = maximum task size in paragraphs
BX = start address of task space
Program: PC-MOS/386 is a multitasking/multiuser MS-DOS-compatible operating
system by The Software Link, Inc.
SeeAlso: AH=1Fh,AH=22h
--------r-D5---------------------------------
INT D5 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D5---------------------------------
INT D5 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D6---------------------------------
INT D6 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D6---------------------------------
INT D6 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D7---------------------------------
INT D7 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D7---------------------------------
INT D7 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------r-D8---------------------------------
INT D8 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D8---------------------------------
INT D8 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------H-D8---------------------------------
INT D8 - Screen Thief v1.00 - RELOCATED IRQ0
Note: Screen Thief relocates IRQs 0 through 7 to INT D8 to INT DF by default,
but may be directed via a commandline switch to use any range
starting at a multiple of 8 between 78h and E0h
SeeAlso: INT 08"IRQ0",INT 2D/AL=10h"Screen Thief",INT 50"DESQview"
SeeAlso: INT D9"Screen Thief"
--------r-D9---------------------------------
INT D9 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-D9---------------------------------
INT D9 - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------H-D9---------------------------------
INT D9 - Screen Thief v1.00 - RELOCATED IRQ1
Note: (see INT D8"Screen Thief")
SeeAlso: INT 09"IRQ1",INT D8"Screen Thief",INT DA"Screen Thief"
--------r-DA---------------------------------
INT DA - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DA---------------------------------
INT DA - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------H-DA---------------------------------
INT DA - Screen Thief v1.00 - RELOCATED IRQ2
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0A"IRQ2",INT D9"Screen Thief",INT DB"Screen Thief"
--------r-DB---------------------------------
INT DB - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DB---------------------------------
INT DB - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------H-DB---------------------------------
INT DB - Screen Thief v1.00 - RELOCATED IRQ3
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0B"IRQ3",INT DA"Screen Thief",INT DC"Screen Thief"
--------u-DC---------------------------------
INT DC - PC/370 v4.1- - API
SeeAlso: INT 60"PC/370"
--------r-DC---------------------------------
INT DC - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DC---------------------------------
INT DC - STSC APL*PLUS/PC - MAY BE USED IN FUTURE RELEASES
--------H-DC---------------------------------
INT DC - Screen Thief v1.00 - RELOCATED IRQ4
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0C"IRQ4",INT DB"Screen Thief",INT DD"Screen Thief"
--------r-DD---------------------------------
INT DD - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DD---------------------------------
INT DD - STSC APL*PLUS/PC v9.0 - PLACE KEYSTROKE EVENTS IN INPUT BUFFER
BX = where to place keystrokes
FFFFh insert before current buffer contents
0000h replace current contents
0001h insert after current contents
CX = number of keystroke events to insert
ES:SI -> data to be placed into buffer (list of WORD key codes)
4000h + N = normal ASCII keystroke N (N = 00h to FFh)
4100h + N = extended ASCII keystroke N (N = 03h to 84h)
SeeAlso: INT 16/AH=05h
--------H-DD---------------------------------
INT DD - Screen Thief v1.00 - RELOCATED IRQ5
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0D"IRQ5",INT DC"Screen Thief",INT DE"Screen Thief"
--------r-DE---------------------------------
INT DE - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DE---------------------------------
INT DE - APL*PLUS/PC - ???
Note: appears to be the same as INT 16
--------H-DE---------------------------------
INT DE - Screen Thief v1.00 - RELOCATED IRQ6
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0E"IRQ6",INT DD"Screen Thief",INT DF"Screen Thief"
--------b-DF---------------------------------
INT DF - Victor 9000 - SuperBIOS
--------r-DF---------------------------------
INT DF - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-DF---------------------------------
INT DF - APL*PLUS/PC - SAME AS INT 10
SeeAlso: INT 10
--------H-DF---------------------------------
INT DF - Screen Thief v1.00 - RELOCATED IRQ7
Note: (see INT D8"Screen Thief")
SeeAlso: INT 0F"IRQ7",INT DE"Screen Thief"
--------r-E0---------------------------------
INT E0 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E0---------------------------------
INT E0 - APL*PLUS/PC - RESTIME HIGH-RESOLUTION TIMER FOR QUAD MF FUNCTION
SeeAlso: INT CF"APL"
--------v-E0---------------------------------
INT E0 - VIRUS - "Micro-128" - ???
Note: Micro-128 also overwrites the upper half of the interrupt table
SeeAlso: INT 9E"VIRUS",INT F1"VIRUS"
--------O-E0---------------------------------
INT E0 - CP/M-86, Concurrent CP/M, DR Multiuser DOS - FUNCTION CALLS
CL = function number
DS,DX = parameters
Return: as appropriate for function
Notes: several functions are covered in more detail in following entries
most of these calls are also supported by Digital Research's DOS Plus
v2.1; the unsupported functions are 26h,29h-2Bh,3Ah,3Dh-62h,71h-8Ch,
90h-92h,94h-97h,9Bh-ABh, and AEh-FFh
SeeAlso: INT 21/AX=4459h,INT 21/AH=E0h"DOS Plus"
Values for function number:
00h terminate calling process (see also INT 21/AH=00h)
01h read a character
02h write character to default console (see also INT 21/AH=02h)
03h read character from default AUX (see also INT 21/AH=03h)
04h write character to default AUX (see also INT 21/AH=04h)
05h write character to default list device (see also INT 21/AH=05h)
06h perform raw I/O on default console (see also INT 21/AH=06h)
07h return default AUX input status
08h return default AUX output status
09h write string to default console (see also INT 21/AH=09h)
0Ah read string from default console (see also INT 21/AH=0Ah)
0Bh return default console input status (see also INT 21/AH=0Bh)
0Ch get BDOS release ID
0Dh reset all disk drives (see also INT 21/AH=0Dh)
0Eh set default drive (see also INT 21/AH=0Eh)
0Fh open file via FCB (see also INT 21/AH=0Fh)
10h close file via FCB (see also INT 21/AH=10h)
11h search for first matching file with FCB (see also INT 21/AH=11h)
12h search for next matching file with FCB (see also INT 21/AH=12h)
13h delete file via FCB (see also INT 21/AH=13h)
14h sequential read via FCB (see also INT 21/AH=14h)
15h sequential write via FCB (see also INT 21/AH=15h)
16h create file via FCB (see also INT 21/AH=16h)
17h rename file via FCB (see also INT 21/AH=17h)
18h get bit map of logged drives
19h get default drive (see also INT 21/AH=19h)
1Ah set DMA address offset
1Bh get default disk allocation vector (see also INT 21/AH=1Bh)
1Ch set default drive to read-only
1Dh get bit map of read-only drives
1Eh set file attributes via FCB (see also INT 21/AX=4301h)
1Fh get address of disk parameter block (see also INT 21/AH=1Fh)
20h get/set default user number
21h read random record via FCB (see also INT 21/AH=21h)
22h write random record via FCB (see also INT 21/AH=22h)
23h compute file size with FCB (see also INT 21/AH=23h)
24h get FCB random record number (see also INT 21/AH=24h)
25h reset specified drives
26h access specified drives (not in DR DOS Plus v2.1)
27h free specified drives
28h write random with FCB, zero fill (see also also INT 21/AH=28h)
2Ah lock records in FCB file (see also INT 21/AH=5Ch)
2Bh unlock records in FCB file (see also INT 21/AH=5Ch)
2Ch set BDOS multisector count
2Dh set BDOS error mode
2Eh get free space on disk
2Fh load, initialize, and jump to process (see also INT 21/AH=4Bh)
30h flush write-deferred buffers
31h get/set system variable (DOS Plus v2.1)
32h call BIOS (XIOS) character routine (see below)
33h set DMA address segment
34h get DMA buffer address
35h CP/M-86 allocate maximum memory
36h allocate maximum memory at specified segment
37h CP/M-86 allocate memory segment (see also INT 21/AH=48h)
38h allocate memory at specified segment
39h CP/M-86 free specified memory segment (see also INT 21/AH=49h)
3Ah CP/M-86 free all memory (not in DOS Plus v2.1)
3Bh load .CMD file into memory
3Ch (DOS Plus v2.1) call RSX program
40h (DR-NET) log on a server
41h (DR-NET) log off a server
42h (DR-NET) send a message
43h (DR-NET) receive a message
44h (DR-NET) get network status
45h (DR-NET) get requestor configuration table
46h (DR-NET) set compatibility attributes
47h (DR-NET) get server configuration table
48h (DR-NET) set network error mode
49h (DR-NET) attach network
4Ah (DR-NET) detach network
4Bh (DR-NET) set default password
4Ch (DR-NET) get-set long timeout
4Dh (DR-NET) get parameter table
50h (DR-NET) get network information
53h get current time (see also INT 21/AH=2Ch)
54h set current time (see also INT 21/AH=2Dh)
55h get binary system date (see also INT 21/AH=2Ah)
56h set system date (see also INT 21/AH=2Bh)
57h allocate system flag
58h deallocate system flag
59h reserve memory in global area
5Ah lock physical drive
5Bh unlock physical drive
5Ch search path for executable file
5Dh load and execute command (see also INT 21/AH=4Bh)
5Eh get/set process exit code
5Fh set country information
60h get country information
63h truncate FCB file (see also INT 21/AH=28h)
64h create/update directory label
65h get directory label
66h get FCB date stamp and password mode
67h write extended FCB
68h set system date and time
69h get system date and time in binary
6Ah establish password for file access
6Bh get OS serial number
6Ch (DOS Plus v2.1) get/set program return code
6Dh get/set console mode
6Eh get/set string delimiter
6Fh write block to default console
70h write block to default list device
71h execute DOS-compatible function
74h set FCB time and date stamps
80h allocate memory
82h deallocate memory
83h poll I/O device
84h wait on system flag
85h set system flag
86h create message queue
87h open message queue
88h delete message queue
89h read from message queue
8Ah conditionally read from message queue
8Bh write to message queue
8Ch conditionally write to message queue
8Dh delay calling process
8Eh call process dispatcher (yield CPU)
8Fh terminate calling process (same as function 00h)
90h create a process
91h set calling process' priority
92h attach to default console
93h detach from default console
95h assign default console to process
96h interpret and execute commandline
97h resident procedure library
98h parse ASCII string into FCB (see also INT 21/AH=29h)
99h return default console
9Ah get address of system data (SYSDAT)
9Bh get system time and date
9Ch return calling process' descriptor
9Dh terminate process by name or PD address
9Eh attach to default list device
9Fh detach from default list device
A0h select default list device
A1h conditionally attach to default list device
A2h conditionally attach to default console
A3h get OS version number
A4h get default list device
A5h attach to default AUX
A6h detach from default AUX
A7h conditionally attach to default AUX
A8h set default AUX
A9h return default AUX
ACh read block from default AUX
ADh (DOS Plus v2.1) write block to default AUX
B0h configure default AUX
B1h get/set device control parameters
B2h send Break through default AUX
B3h allocate physical memory
B4h free physical memory
B5h map physical memory
B6h nondestructive message queue read
B7h timed wait on system flag
B8h get/set I/O port mapping
B9h set list device timeout
BAh set AUX timeout value
BBh execute XIOS service
BDh (DR Multiuser DOS) delay
FFh return 80386 to native mode
Values for DOS Plus v2.1 XIOS functions:
00h terminate program
01h ???
02h check for console input status
03h read character from console
04h write character to console
05h write character to list device
06h write character to auxiliary device
07h read cahracter from auxiliary device
0Fh get list device status
10h-14h reserved
15h device initialization
16h check console output status
17h-7Fh reserved
---BBC Acorn---
80h get XIOS version
81h get Tube semaphore
82h release Tube semaphore
83h select text/graphics
84h update B&W graphics rectangle
85h update color graphics rectangle
86h get/release/update mouse
87h get system error info
88h entry in CLOCK called by WatchDog RSP
89h BBC OSBYTE function
8Ah BBC OSWORD function
DR Multiuser DOS Error Return Codes:
00h no error
01h system call not implemented
02h illegal system call number
03h cannot find memory
04h illegal flag number
05h flag overrun
06h flag underrun
07h no unused Queue Descriptors
08h no free queue buffer
09h cannot find queue
0Ah queue in use
0Ch no free Process Descriptors
0Dh no queue access
0Eh empty queue
0Fh full queue
10h CLI queue missing
11h no 8087 in system
12h no unused Memory Descriptors
13h illegal console number
14h no Process Descriptor match
15h no console match
16h no CLI process
17h illegal disk number
18h illegal filename
19h illegal filetype
1Ah character not ready
1Bh illegal Memory Descriptor
1Ch bad return from BDOS load
1Dh bad return from BDOS read
1Eh bad return from BDOS open
1Fh null command
20h not owner of resource
21h no CSEG in load file
22h process Descriptor exists on Thread Root
23h could not terminate process
24h cannot attach to process
25h illegal list device number
26h illegal password
28h external termination occurred
29h fixup error upon load
2Ah flag set ignored
2Bh illegal auxilliary device number
--------O-E0----CL03-------------------------
INT E0 - DR Multiuser DOS - "A_READ" - READ CHARACTER FROM AUX DEVICE
CL = 03h
Return: AL = ASCII character
Notes: A_READ reads the next 8-bit character from the logical auxilliary
input device (AUXn:); control is not returned to the calling
process until a character has been read.
if another process owns AUX, this call blocks until the device becomes
available
SeeAlso: INT 21/AH=03h,INT E0/CL=04h,INT E0/CL=07h,INT E0/CL=A5h,INT E0/CL=ACh
--------O-E0----CL04-------------------------
INT E0 - DR Multiuser DOS - "A_WRITE" - WRITE CHARACTER TO AUX DEVICE
CL = 04h
DL = ASCII character
Return: nothing
Note: if another process owns AUX, this call blocks until the device becomes
available
SeeAlso: INT 21/AH=04h,INT E0/CL=03h,INT E0/CL=08h,INT E0/CL=A5h,INT E0/CL=ADh
--------O-E0----CL07-------------------------
INT E0 - DR Multiuser DOS - "A_STATIN" - GET INPUT STATUS OF AUX DEVICE
CL = 07h
Return: AL = status
00h not ready
FFh character available
Desc: determine whether the current AUX device has input available
SeeAlso: INT E0/CL=03h,INT E0/CL=08h
--------O-E0----CL08-------------------------
INT E0 - DR Multiuser DOS - "A_STATOUT" - GET OUTPUT STATUS OF AUX DEVICE
CL = 08h
Return: AL = status
00h not ready
FFh ready for output
Desc: determine whether the current AUX device is able to accept more output
SeeAlso: INT E0/CL=04h,INT E0/CL=07h
--------O-E0----CL59-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "S_MEMORY" - RESERVE MEMORY IN GLOBAL AREA
CL = 59h
DX = size in bytes
Return: AX = FFFFh if failed
AX = other if successful
ES:BX -> reserved memory
--------O-E0----CL86-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_MAKE" - CREATE MESSAGE QUEUE
CL = 86h
DS:DX -> queue descriptor (see below)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=87h
Format of queue descriptor:
Offset Size Description
00h 2 WORDs internal use, initialize to zeros
04h WORD flags
06h 8 BYTEs queue name
0Eh WORD length of message
10h WORD number of messages
12h 4 WORDs internal use, initialize to zeros
1Ah WORD offset in system area of buffer for messages
--------O-E0----CL87-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_OPEN" - OPEN MESSAGE QUEUE
CL = 87h
DS:DX -> queue parameter block (see below)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=86h,INT E0/CL=89h
Format of queue parameter block:
Offset Size Description
00h WORD internal use, initialize to zero
02h WORD queue ID (set by INT E0/CL=87h)
04h WORD internal use, initialize to zero
06h WORD offset of queue message buffer
08h 8 BYTEs queue name
--------O-E0----CL89-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_READ" - READ MESSAGE QUEUE
CL = 89h
DS:DX -> queue parameter block (see INT E0/CL=87h)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=87h,INT E0/CL=8Ah,INT E0/CL=8Bh
--------O-E0----CL8A-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_CREAD" - CONDITIONALLY READ MSG QUEUE
CL = 8Ah
DS:DX -> queue parameter block (see INT E0/CL=87h)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=87h,INT E0/CL=89h,INT E0/CL=8Ch
--------O-E0----CL8B-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_WRITE" - WRITE MESSAGE QUEUE
CL = 8Bh
DS:DX -> queue parameter block (see INT E0/CL=87h)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=89h,INT E0/CL=8Ch
--------O-E0----CL8C-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "Q_CWRITE" - CONDITIONALLY WRITE MSG QUEUE
CL = 8Ch
DS:DX -> queue parameter block (see INT E0/CL=87h)
Return: AX = status
0000h success
FFFFh failure
CX = error code
SeeAlso: INT E0/CL=8Ah,INT E0/CL=8Bh
--------O-E0----CL8E-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "P_DISPATCH" - CALL DISPATCHER
CL = 8Eh
DX = FFFFh (optional) to force dispatch
Return: nothing
Desc: allow other processes of the same or higher priority to run if they
are ready
Note: if DX=FFFFh, a dispatch is forced even if no other process is ready
SeeAlso: INT E0/CL=91h
--------O-E0----CL91-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "P_PRIORITY" - SET PROCESS PRIORITY
CL = 91h
DL = new priority (00h highest to FFh lowest)
Note: sets priority of calling process; transient processes are initialized
to priority C8h
SeeAlso: INT E0/CL=8Eh
--------O-E0----CL93-------------------------
INT E0 - ConcCP/M,DR Multiuser DOS - "C_DETACH" - DETACH FROM DEFAULT CONSOLE
CL = 93h
Return: AX = status
0000h successfully detached
FFFFh detach failed
--------O-E0----CLA5-------------------------
INT E0 - DR Multiuser DOS - "A_ATTACH" - ATTACH AUX DEVICE
CL = A5h
Desc: attaches the default auxiliary device to the calling process unless
it is already attached to another process, in which case the call
blocks until the device becomes available
Note: this call should be used before attempting to read or write from
the AUX device; however, the I/O calls internally call this function
to ensure device ownership
SeeAlso: INT E0/CL=03h,INT E0/CL=04h,INT E0/CL=A6h,INT E0/CL=A7h,INT E0/CL=A8h
SeeAlso: INT E0/CL=ACh,INT E0/CL=ADh,INT E0/CL=B0h
--------O-E0----CLA6-------------------------
INT E0 - DR Multiuser DOS - "A_DETACH" - DETACH FROM AUX DEVICE
CL = A6h
Return: AX = status
0000h successfully detached
FFFFh detach failed
CX = error code
SeeAlso: INT E0/CL=A5h,INT E0/CL=A7h
--------O-E0----CLA7-------------------------
INT E0 - DR Multiuser DOS - "A_CATTACH" - CONDITIONALLY ATTACH TO AUX DEVICE
CL = A7h
Return: AX = status
0000h attached
FFFFh unable to attach
Desc: attaches the default auxiliary device to the calling process if it is
available
Note: does not block if the device is already in use
SeeAlso: INT E0/CL=A5h,INT E0/CL=A6h,INT E0/CL=A8h,INT E0/CL=B0h
--------O-E0----CLA8-------------------------
INT E0 - DR Multiuser DOS - "A_SET" - SET DEFAULT AUX DEVICE NUMBER
CL = A8h
DL = auxiliary device number
Return: AX = status
0000h successful
FFFFh failed
CX = error code
Desc: specify which physical device will become AUX
SeeAlso: INT E0/CL=A5h,INT E0/CL=A9h
--------O-E0----CLA9-------------------------
INT E0 - DR Multiuser DOS - "A_GET" - GET DEFAULT AUX DEVICE NUMBER
CL = A9h
Return: AL = current default auxiliary device number
Desc: determine which physical device is currently AUX
SeeAlso: INT E0/CL=A8h
--------O-E0----CLAC-------------------------
INT E0 - DR Multiuser DOS - "A_READBLK" - READ STRING FROM AUX DEVICE
CL = ACh
DS:DX -> character control block (CHCB) (see below)
Return: AX = number of characters read
Desc: read characters from the default auxiliary (AUXn:) device into a buffer
until the buffer is full or the device is no longer ready
Notes: if the device is initially not ready, blocks until at least one
character has been read
if another process owns AUX, this call blocks until the device becomes
available
SeeAlso: INT E0/CL=03h,INT E0/CL=A5h,INT E0/CL=ADh
Format of character control block (CHCB):
Offset Size Description
00h DWORD pointer to character buffer
04h WORD length of character buffer
--------O-E0----CLAD-------------------------
INT E0 - DR Multiuser DOS - "A_WRITEBLK" - WRITE STRING TO AUX DEVICE
CL = ADh
DS:DX -> character control block (see INT E0/CL=ACh)
Return: AX = number of characters written
Note: does not return until at least one character has been written
SeeAlso: INT E0/CL=04h,INT E0/CL=A5h,INT E0/CL=ACh
--------O-E0----CLB0-------------------------
INT E0 - DR Multiuser DOS - "A_CONFIG" - GET/SET AUX DEVICE PARAMETERS
CL = B0h
DX:DX -> AUX device parameter block (see below)
Return: AX = status
0000h successful
parameter block updated
FFFFh failed
CX = error code
SeeAlso: INT E0/CL=A5h,INT E0/CL=B1h
Format of AUX device parameter block:
Offset Size Description
00h BYTE function (00h get, 01h set)
01h BYTE baud rate (see below) FFh = don't change/unknown
02h BYTE parity (see below)
03h BYTE stop bits (00h one, 01h 1.5, 02h two, FFh unknown/don't change)
04h BYTE data bits (05h-08h or FFh unknown/don't change)
05h BYTE handshake (00h none, 01h DTS/DSR, 02h RTS/CTS, 04h XON/XOFF,
FFh unknown/don't change)
06h BYTE XON character, FFh unknown/don't change
07h BYTE XOFF character, FFh unknown/don't change
Values for parity:
00h none
01h odd
02h none
03h even
04h stick parity bit
FFh don't change/unknown
Values for baud rate:
00h 50 baud
01h 62.5 baud
02h 75 baud
03h 110 baud
04h 134.5 baud
05h 150 baud
06h 200 baud
07h 300 baud
08h 600 baud
09h 1200 baud
0Ah 1800 baud
0Bh 2000 baud
0Ch 2400 baud
0Dh 3600 baud
0Eh 4800 baud
0Fh 7200 baud
10h 9600 baud
11h 19200 baud
12h 38400 baud
13h 56000 baud
14h 76800 baud
15h 115200 baud
--------O-E0----CLB1-------------------------
INT E0 - DR Multiuser DOS - "A_CONTROL" - GET/SET AUX CONTROL PARAMETERS
CL = B1h
DS:DX -> AUX device control block (see below)
Return: AX = status
0000h successful
control block updated
FFFFh failed
CX = error code
SeeAlso: INT E0/CL=B0h,INT E0/CL=B2h
Format of AUX device control block:
Offset Size Description
00h BYTE function (00h get, 01h set)
01h BYTE DTR state (00h low, 01h high, FFh unknown/don't change)
02h BYTE RTS state (00h low, 01h high, FFh unknown/don't change)
03h BYTE DSR state (00h low, 01h high, FFh unknown/don't change)
04h BYTE CTS state (00h low, 01h high, FFh unknown/don't change)
05h BYTE DCD state (00h low, 01h high, FFh unknown/don't change)
06h BYTE RI state (00h inactive, 01h active, FFh unknown/don't change)
--------O-E0----CLB2-------------------------
INT E0 - DR Multiuser DOS - "A_BREAK" - SEND BREAK TO AUX DEVICE
CL = B2h
DX = duration of break in system ticks (0001h-FFFFh)
Return: AX = status
0000h successful
break signal completed
FFFFh failed
CX = error code
Note: if the AUX device is currently owned by another process, this call will
block until the device becomes available
SeeAlso: INT E0/CL=A5h,INT E0/CL=B1h
--------O-E0----CLBD-------------------------
INT E0 - DR Multiuser DOS - "P_DELAY" - DELAY EXECUTION
CL = BDh
DX = delay in system ticks
Return: after the delay elapses
Notes: the length of a system tick is installation-dependent (typically
1/50 or 1/60 second); the length may be determined by reading the
TICKSPERSEC value from the system data segment
the actual delay before the process is rescheduled to run may be up to
one tick longer than requested; the delay between rescheduling and
actual execution cannot be predicted if higher-priority processes
are awaiting a turn at the CPU
SeeAlso: INT 15/AH=86h,INT 1A/AX=FF01h,INT 2F/AX=1224h,INT 62/AX=0096h
--------r-E1---------------------------------
INT E1 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-E1---------------------------------
INT E1 - PC Cluster Disk Server Information
SeeAlso: INT E2
--------r-E2---------------------------------
INT E2 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-E2---------------------------------
INT E2 - PC Cluster Program
--------r-E3---------------------------------
INT E3 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E40005-----------------------------
INT E4 - Logitech Modula v2.0 - MonitorEntry
AX = 0005h
BX = priority
SeeAlso: AX=0006h
--------r-E40006-----------------------------
INT E4 - Logitech Modula v2.0 - MonitorExit
AX = 0006h
SeeAlso: AX=0005h
--------r-E4---------------------------------
INT E4 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E5---------------------------------
INT E5 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E6---------------------------------
INT E6 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E7---------------------------------
INT E7 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E8---------------------------------
INT E8 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-E9---------------------------------
INT E9 - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-EA---------------------------------
INT EA - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-EB---------------------------------
INT EB - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------r-EC---------------------------------
INT EC - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC
BASIC.COM/BASICA.COM do not restore vector on termination
--------N-EC---------------------------------
INT EC - used by Alloy NTNX
--------r-EC---------------------------------
INT EC - Exact - RUNTIME INTERFACE MULTIPLEXOR
AX = function number (0000h to 0140h)
STACK: DWORD address to return to
any arguments required by function
Return: STACK: return address popped, but otherwise unchanged
Desc: this is the interface from applications to the runtime system by Exact
Automatisering B.V. of the Netherlands. By using this interrupt,
it can provide DLL-style capabilities under MS-DOS.
Note: the interrupt handler removes the return address and flags placed on
the stack by the INT EC, then jumps to the appropriate function
--------r-ED---------------------------------
INT ED - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
INT 80 through INT ED are modified but not restored by Direct Access
v4.0, and may be left dangling by other programs written with the
same version of compiled BASIC
SeeAlso: INT EC"BASIC",INT EE"BASIC"
--------r-EE---------------------------------
INT EE - IBM ROM BASIC - used while in interpreter
Notes: called by ROM BASIC, but pointed at IRET by BASIC.COM/BASICA.COM
BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT ED"BASIC",INT EE"BASIC"
--------r-EF---------------------------------
INT EF - BASIC - ORIGINAL INT 09 VECTOR
Note: BASIC.COM/BASICA.COM do not restore vector on termination
SeeAlso: INT EE"BASIC",INT F0"BASIC"
--------O-EF----CX0473-----------------------
INT EF - GEM - INTERFACE
CX = 0473h
DS:DX -> GEM parameter block
--------r-F0---------------------------------
INT F0 - BASICA.COM, GWBASIC, compiled BASIC - ORIGINAL INT 08 VECTOR
Note: BASICA.COM does not restore vector on termination
SeeAlso: INT EF"BASIC"
--------*-F1---------------------------------
INT F1 - reserved for user interrupt
--------s-F1---------------------------------
INT F1 - SPEECH.COM - CONVERT TEXT STRING TO SPEECH
DS:BX -> '$'-terminated text string
Program: SPEECH.COM is a resident text-to-speech converter by Douglas Sisco
--------s-F1---------------------------------
INT F1 - Andy C. McGuire SPEECH.COM/SAY.COM
SeeAlso: INT F2"SPEECH"
--------U-F1---------------------------------
INT F1 - AQUEDUCT, PIPELINE - GET DATA AREA ADDRESS
Return: AX:BX -> data area
Program: AQUEDUCT and PIPELINE are TSRs by James W. Birdsall to connect COM1
and COM2 in software
Note: The installation check consists of testing for the following signature
immediately preceding the interrupt handler: "JWBtvv" where 't' is
either "A" for AQUEDUCT or "P" for PIPELINE and "vv" is a two-digit
version number
Index: installation check;AQUEDUCT|installation check;PIPELINE
--------v-F1---------------------------------
INT F1 - VIRUS - "Violetta" - ???
Note: used but not chained by virus
SeeAlso: INT E0"VIRUS",INT FF"VIRUS"
--------*-F2---------------------------------
INT F2 - reserved for user interrupt
--------s-F2---------------------------------
INT F2 - Andy C. McGuire SPEECH.COM/SAY.COM
SeeAlso: INT F1"SPEECH"
----------F2---------------------------------
INT F2 - ICCTSR 1.0 - ImageCapture COLOR Developer's Kit - API
AH = function
01h power up
02h power down
03h set controls
04h capture image
05h display image
06h read file
07h write file
08h write array
09h read pixel
0Ah write pixel
0Bh check if VGA present
0Ch set video mode
0Dh check for keystroke
0Eh delay
???
Return: ???
Program: ImageCapture is a product of International Computers
SeeAlso: INT F3"ICCTSR"
--------*-F3---------------------------------
INT F3 - reserved for user interrupt
--------s-F3---------------------------------
INT F3 - SoundBlaster - POINTER TO ECHO VALUE
Note: this is not a vector, but a pointer to a DWORD containing the echo
value selected with SET-ECHO.EXE
SeeAlso: INT 2F/AX=FBFBh
----------F3---------------------------------
INT F3 - ICCTSR 1.0 - HANDSHAKE ID VECTOR
Program: ImageCapture is a product of International Computers
SeeAlso: INT F2"ICCTSR"
--------*-F4---------------------------------
INT F4 - reserved for user interrupt
--------T-F4---------------------------------
INT F4 - DoubleDOS - GIVE UP REST OF CURRENT CLOCK TICK AND ALL OF NEXT TICK
SeeAlso: INT 21/AH=EEh"DoubleDOS",INT FE"DoubleDOS"
--------*-F5---------------------------------
INT F5 - reserved for user interrupt
--------T-F5---------------------------------
INT F5 - DoubleDOS - ???
--------*-F6---------------------------------
INT F6 - reserved for user interrupt
--------T-F6---------------------------------
INT F6 - DoubleDOS - ???
--------*-F7---------------------------------
INT F7 - reserved for user interrupt
--------T-F7---------------------------------
INT F7 - DoubleDOS - ???
----------F700-------------------------------
INT F7 - FSBBS 2.0 - CONFIGURATION RECORD
AH = 00h
AL = function
00h get configuration record
Return: DS:DX -> configuration record
01h set configuration record
02h get path for option
DS:DX -> option name
Return: DS:DX -> path
03h determine whether configuration record set
Return: AX = status
0000h set
0001h not yet set
04h get link state
Return: AX = state
0000h unlinked
0001h linked
Notes: this information is preliminary and still subject to change
all of the INT F7 calls for FSBBS are used for interprogram
communication between the BBS kernel and the programs it spawns
SeeAlso: AH=01h
----------F701-------------------------------
INT F7 - FSBBS 2.0 - USER RECORD
AH = 01h
AL = function
00h get user record for user currently online
Return: DS:DX -> user record
01h set user record
DS:DX -> user record
SeeAlso: AH=00h,AH=02h
----------F702-------------------------------
INT F7 - FSBBS 2.0 - GET ACCOUNT NAME
AH = 02h
Return: DS:DX -> 8-character blank-padded account name
SeeAlso: AH=01h
----------F703-------------------------------
INT F7 - FSBBS 2.0 - TERMINAL NUMBER
AH = 03h
AL = function
00h get terminal index number
Return: DX = index number
01h set terminal index number
DX = terminal index
----------F704-------------------------------
INT F7 - FSBBS 2.0 - PASSDATA BUFFER
AH = 04h
AL = function
00h get PassData buffer contents
DS:DX -> buffer for PassData contents
01h set PassData contents
DS:DX -> buffer containing new PassData
CH = length of data in buffer
----------F705-------------------------------
INT F7 - FSBBS 2.0 - TIMER FUNCTIONS
AH = 05h
AL = function
00h get time remaining
Return: DX = number of minutes remaining
01h get current time
Return: DS:DX -> 8-character time string
02h increment time
DX = number of additional minutes
03h decrement time
DX = number of minutes
SeeAlso: AH=06h
----------F706-------------------------------
INT F7 - FSBBS 2.0 - FUNCTION AVAILABILITY
AH = 06h
AL = function
00h determine whether function is available
DX = index of function
01h set function availability
DX = index of function
???
SeeAlso: AH=05h,AH=07h
----------F707-------------------------------
INT F7 - FSBBS 2.0 - DUMP FUNCTIONS
AH = 07h
AL = function
00h get current dump mode
Return: DL = mode
01h set dump mode
DL = mode
SeeAlso: AH=06h
--------*-F8---------------------------------
INT F8 - reserved for user interrupt
--------h-F8---------------------------------
INT F8 - TANDY??? - 100 HZ INTERRUPT
Note: this vector is not used on the Tandy 1000TL
SeeAlso: INT FA"USART"
--------T-F8---------------------------------
INT F8 - DoubleDOS - ???
--------*-F9---------------------------------
INT F9 - reserved for user interrupt
--------T-F9---------------------------------
INT F9 - DoubleDOS - ???
--------*-FA---------------------------------
INT FA - reserved for user interrupt
--------h-FA---------------------------------
INT FA - TANDY??? - SERIAL PORT USART INTERRUPT
Note: this vector is not used on the Tandy 1000TL
SeeAlso: INT F8"100 HZ",INT FB"USART"
--------T-FA---------------------------------
INT FA - DoubleDOS - TURN OFF TIMESHARING
SeeAlso: INT 21/AH=EAh"DoubleDOS",INT FB"DoubleDOS"
--------*-FB---------------------------------
INT FB - reserved for user interrupt
--------h-FB---------------------------------
INT FB - TANDY??? - KEYBOARD USART RECEIVE INTERRUPT
SeeAlso: INT FA"USART"
--------T-FB---------------------------------
INT FB - DoubleDOS - TURN ON TIMESHARING
SeeAlso: INT 21/AH=EBh"DoubleDOS",INT FA"DoubleDOS"
--------*-FC---------------------------------
INT FC - reserved for user interrupt
--------T-FC---------------------------------
INT FC - DoubleDOS - GET CURRENT SCREEN BUFFER ADDRESS
Return: ES = segment of display buffer
Desc: determine the address of the virtual screen to which the program
should write instead of the actual video memory, so that the
multitasked programs do not interfere with each other's output
Note: the display buffer may be moved if multitasking is enabled
SeeAlso: INT 21/AH=ECh"DoubleDOS",INT FB"DoubleDOS"
--------*-FD---------------------------------
INT FD - reserved for user interrupt
--------T-FD---------------------------------
INT FD - DoubleDOS - ???
--------S-FD---------------------------------
INT FD - TFPCX - INSTALLATION CHECK
AH = function (see separate entries below)
Program: TFPCX is an interface between modem and terminal program for packet-
radio communications
Notes: the installation check consists of testing for the string "N5NX" three
bytes beyond the interrupt handler; INT FD is the default, but may
be changed, so the full installation check consists of scanning
for the signature
TFPCX returns AX=FFFFh on any unsupported function call
SeeAlso: AH=01h,AH=03h,AH=FEh
--------S-FD01-------------------------------
INT FD - TFPCX - TEST FOR CHARACTER WAITING
AH = 01h
Return: AX = status
0000h no characters waiting
0001h character available for input
Program: TFPCX is an interface between modem and terminal program for packet-
radio communications
SeeAlso: AH=02h
--------S-FD02-------------------------------
INT FD - TFPCX - GET CHARACTER
AH = 02h
Return: AL = character
Notes: this call is only allowed if AH=01h indicated that a character is
available
all available characters should be read before sending any additional
characters
SeeAlso: AH=01h,AH=03h
--------S-FD03-------------------------------
INT FD - TFPCX - OUTPUT CHARACTER
AH = 03h
AL = character to send
SeeAlso: AH=02h
--------S-FDFE-------------------------------
INT FD - TFPCX - GET VERSION
AH = FEh
Return: AH = major version
AL = minor version
Program: TFPCX is an interface between modem and terminal program for packet-
radio communications
SeeAlso: AH=01h,AH=03h
--------B-FE---------------------------------
INT FE - AT/XT286/PS50+ - destroyed by return from protected mode
Note: the ROM BIOS uses 0030h:0100h as the initial stack on startup, which
is the last fourth of the interrupt vector table. If the processor
is returned to real mode via a hardware reset (the only possibility
on an 80286, though there are a number of ways of generating one),
then the BIOS startup code stacks three words on its scratch stack
before determining that a return to real mode has been requested.
As a result, INT FE and INT FF are corrupted.
SeeAlso: INT FF"XT286"
--------T-FE---------------------------------
INT FE - DoubleDOS - GIVE UP TIME
AL = number of 55ms time slices to give away
Return: after other program (if active) has run
SeeAlso: INT 21/AH=EEh"DoubleDOS",INT F4"DoubleDOS"
--------G-FE---------------------------------
INT FE - Turbo Debugger 8086 v2.5+ - OVERLAY MANAGER
SeeAlso: INT 3F
--------B-FF---------------------------------
INT FF - AT/XT286/PS50+ - destroyed by return from protected mode
Note: (see INT FE"XT286")
SeeAlso: INT FE"XT286"
--------b-FF---------------------------------
INT FF - Z100 - WARM BOOT
SeeAlso: INT 40"Z100"
--------Q-FF---------------------------------
INT FF U - QEMM-386.SYS v6.0+ - internal
Notes: requires that a byte in the conventional-memory stub be set to the
desired function number (00h through 0Ch)
Functions supported by QEMM:
00h reflect back to Virtual86-mode interrupt handler (default)
01h ???
02h access DR7???
03h QPI upcall (see INT 67/AH=3Fh)
04h ???
05h ???
06h INT 15/AH=87h
07h EMS services (see INT 67/AH=40h-5Dh)
08h ???
09h QEMM exception handler
0Ah XMS services (see INT 2F/AX=4310h)
0Bh Virtual DMA Services (see INT 4B/AX=8102h)
0Ch ???
--------v-FF---------------------------------
INT FF - VIRUS - "Violetta" - ???
Note: used but not chained by virus
SeeAlso: INT E0"VIRUS",INT F1"VIRUS"
--------!---FILELIST-------------------------
Please redistribute the following files unmodified as a group, in a trio of
archives named INTER39A through INTER39C (preferably the original authenticated
PKZIP archives):
INTERRUP.1ST the read-me file, containing credits, availability info
INTERRUP.A INT 00 through INT 14/0F
INTERRUP.B INT 14/10 through INT 15
INTERRUP.C INT 16 through INT 21/41
INTERRUP.D INT 21/42 through INT 21/7F
INTERRUP.E INT 21/80 through INT 21/FF
INTERRUP.F INT 22 through INT 2F/7F
INTERRUP.G INT 2F/80 through INT 2F/FF
INTERRUP.H INT 30 through INT 60
INTERRUP.I INT 61 through INT 68
INTERRUP.J INT 69 through INT FF
INTERRUP.PRI a brief introduction to interrupts
INTPRINT.COM a simple formatter that also generates a list summary
INTPRINT.DOC instructions for INTPRINT
86BUGS.LST a listing of CPU bugs and undocumented features
CMOS.LST a description of the CMOS RAM data bytes
GLOSSARY.LST a glossary of terms, abbreviations, and acronyms
MEMORY.LST format of the BIOS data area
PORTS.LST a listing of I/O ports
COMBINE.BAT combine the pieces of the list into a single file
The following files should be distributed in an archive called INTER39D:
INT.COM invoke interrupts from commandline
INT2HLP.BAT Perl script to convert list into QuickHelp database
INT2GUID.* convert list into TurboPower GUIDE or POPHELP database
INT2QH.* program to convert list into QuickHelp database
INTERVUE.EXE indexed interrupt list browser
INTHELP.* convert list into TurboPower GUIDE database
INTLIST.E Epsilon extension for handling list
INTLIST.ICO Windows icon for INTERVUE
INTPRINT.C source code for INTPRINT
RB2NG.* convert list into Norton Guides database
This compilation is Copyright (c) 1989,1990,1991,1992,1993,1994 Ralf Brown
--------!---CONTACT_INFO---------------------
Internet: ralf@telerama.lm.com !!NOTE NEW DOMAIN NAME!!
UUCP: {uunet,harvard}!telerama.lm.com!ralf
FIDO: Ralf Brown 1:129/26.1
or post a message to me in the DR_DEBUG echo (I probably won't see it
unless you address it to me)
CIS: >INTERNET:ralf@telerama.lm.com