home *** CD-ROM | disk | FTP | other *** search
/ C!T ROM 2 / ctrom_ii_b.zip / ctrom_ii_b / PROGRAM / FOXPRO / RRFP / RRFP.DOC < prev    next >
Text File  |  1992-11-03  |  10KB  |  229 lines

  1.                        Concentric Data Systems, Inc.
  2.           110 Turnpike Road, Westborough, MA 01581 508-366-1122
  3.  
  4.  
  5.  
  6. Dear R&R Version 4.0 User:
  7.  
  8. In the Data Based Advisor Forum you'll find the R&R FoxPro 2 Retrofit
  9. Kit in the Database Tools library (Library 7). This kit adds support for
  10. FoxPro 2.0 compact and compound index files to R&R Version 4.0. Please
  11. read on for installation instructions.
  12.  
  13. The FoxPro 2 Retrofit Kit contains the following files from R&R Version
  14. 4.0f: RR.EXE, RR.OVL, RRUNTIME.EXE, and RRUN.EXE. To minimize download
  15. time, the files are packed into two self-unpacking files named RRFP1.EXE
  16. and RRFP2.EXE. Also, there's a RREADME file containing documentation
  17. updates, which is included in this file at the end of the letter.
  18.  
  19. To install the FoxPro 2 Retrofit Kit:
  20.  
  21. 1) Download RRFP1.EXE and RRFP2.EXE into your R&R Version 4 directory.
  22.  
  23. 2) Enter the following command to install RR.EXE, RRUNTIME.EXE, and
  24.    RRUN.EXE.
  25.  
  26.      RRFP1
  27.  
  28.    If you don't want to install the runtime, enter the command as
  29.    follows:
  30.  
  31.      RRFP1 RR.EXE
  32.  
  33. 3) Enter the following command to install RR.OVL.
  34.  
  35.      RRFP2
  36.  
  37. 4) Backup RRFP1.EXE and RRFP2.EXE to diskette and delete them from
  38.    your hard disk.
  39.  
  40. You may install the FoxPro 2 Retrofit Kit any number of times if you have
  41. multiple copies of R&R. You may freely copy and distribute the FoxPro 2
  42. Retrofit Kit if you need to send a copy to another R&R Version 4.0 user.
  43. The FoxPro 2 Retrofit Kit works only when installed into an existing R&R
  44. Version 4.0 directory.
  45.  
  46. Special Offer:
  47.  
  48. I'd like to take this opportunity to introduce you to R&R Worksheet
  49. Report Writer. It has the same great features as R&R for dBASE, Version 3,
  50. and works with database worksheets created by Lotus 1-2-3 or Symphony.
  51. Registered R&R Version 4 users can order one copy for 1/2 price, only $75,
  52. until August 31, 1991. The product includes our standard 30-day money-back
  53. guarantee. Please call 800-325-9035 or 508-366-1122 to order your copy today.
  54.  
  55. Thank you for selecting R&R Report Writer. We're glad to serve you and hope
  56. you'll recommend R&R to your friends and colleagues.
  57.  
  58. Sincerely,
  59.  
  60.  
  61. Robert Hershfield
  62. Product Manager
  63.  
  64. --------------------------------------------------------------------------
  65.  
  66. RREADME - R&R Report Writer for dBASE and Compatibles, Version 4
  67.  
  68. This file contains information and corrections that were not available
  69. when the R&R documentation was printed.
  70.  
  71. SUPPORT FOR ADDITIONAL INDEX FILE FORMATS
  72.  
  73. R&R now supports FoxPro Version 2 index file formats: compact IDX indexes
  74. and CDX indexes.
  75.  
  76. RRSETUP
  77.  
  78. Display and display adapter:
  79. R&R can now automatically detect the type of display and display adapter
  80. used by the system on which it runs. To enable this automatic detection,
  81. retain the default setting of "Automatic" for the "Display" and "Display 
  82. adapter" fields in RRSETUP. If the automatically determined settings 
  83. are not appropriate, use RRSETUP to select the desired display and 
  84. display adapter.
  85.  
  86. Hercules display adapters:
  87. If you use a monochrome display and a Hercules display adapter configured 
  88. for "Full" mode, use RRSETUP to select "Monochrome" as your display. Do not 
  89. use the "Automatic" option.
  90.  
  91. INTERACTIVE R&R
  92.  
  93. GLOBAL DEFAULT INTERNATIONAL PUNCTUATION
  94. In general, the numeric punctuation you select with the /Global Default 
  95. International Punctuation command controls the way you enter numeric values 
  96. in the product. However, you must use US numeric punctuation (i.e. a dot
  97. decimal symbol and a comma thousands separator) in the following places:
  98. numeric constants in calculated field expressions, numeric values indicating
  99. point size of fonts used in memo fields, and numeric constants used as scope
  100. values or in filter expressions in the runtime control file.
  101.  
  102. RUNTIME
  103.  
  104. RI_MINDEX
  105. In addition to changing the saved master index, you can use the RI_MINDEX 
  106. field in the runtime control file to supply a master index for a report that 
  107. was saved without an index or to remove a saved master index from a report. 
  108. To supply a master index, follow the instructions in the User's Guide for 
  109. providing a master index name. To remove a master index, place the letter 
  110. R (for record number order) preceded by a comma in RI_MINDEX (i.e. ,R).
  111.  
  112. RI_FILTER
  113. RI_FILTER expressions can now include total fields, as long as the total
  114. fields have been designated as pre-processed with the /Field Total Options
  115. Processing command and as long as the total fields reset on the highest
  116. level (most inclusive) group field for which a pre-processed total has
  117. been defined. Filter expressions can also include calculated fields that
  118. are based on such total fields. As a general rule, RI_FILTER expressions
  119. can include any field that can be used in an R&R query.
  120.  
  121. Runtime control file:
  122. When you run an R&R report with the runtime program, the runtime control 
  123. file is opened for shared access. In network environments, this allows
  124. multiple users to access and modify different records in the control file
  125. simultaneously. The way in which this file is opened is not affected by the 
  126. "Allow file write access" setting in your R&R configuration file.
  127.  
  128. Runtime temporary file names:
  129. When you use the /I argument to append a unique user ID to the runtime
  130. status and temporary files, the runtime now creates temporary file names 
  131. that begin with #R. For example, if you issue the following command to 
  132. specify USER2 as a unique user name, R&R will create temporary files named 
  133. #RUSER2.*
  134.     RUN RRUNTIME RRUNIN 5 USER2/I
  135.  
  136. Runtime error messages:
  137. Runtime now displays error messages that are generated before the runtime
  138. output file is created.
  139.  
  140. Alternate video modes:
  141. Runtime assumes an 80-column video mode. If you are using more than 80
  142. columns, you should not display runtime reports on screen or use the 
  143. RI_DISPERR or RI_STATUS runtime control fields to have R&R display error 
  144. and status messages on screen.
  145.  
  146. If you use an 80-column video mode that allows more than 25 lines
  147. on the screen, you can call the runtime with a switch that tells
  148. R&R to display any error messages, banners, and menus on the last line 
  149. of the screen, rather than on the 25th line (the default). R&R will continue
  150. to use the top 24 lines for reports that are displayed. Any lines between
  151. the 25th line and the last line on your screen will be unchanged.
  152.  
  153. To enable support for alternative video modes, use the /S switch when
  154. you call the runtime. Without a numeric argument, /S will cause R&R to 
  155. automatically detect how many lines are used. If the number of lines R&R 
  156. detects is not appropriate, use (number)/S, where number is the total 
  157. number of lines on the screen.
  158.  
  159. For example, the following runtime command issued from within an application
  160. program will run all the reports specified in the RRUNIN.DBF control 
  161. file and will display any error messages, banners, and menus on the 
  162. automatically detected last line of the screen: RUN RRUNTIME RRUNIN /S.
  163. On the other hand, the following command will display such messages on
  164. the 50th line of the screen: RUN RRUNTIME RRUNIN 50/S.
  165.  
  166. Batch files:
  167. Because of a change in RRUNTIME, the runtime swapper program, applications
  168. will not be swapped if they call the runtime using a batch file. To cause
  169. the runtime to swap such an application, define a memory variable containing
  170. the string "rruntime" or "RRUNTIME" (do not mix upper and lower case). 
  171. This will enable the runtime program to recognize the application as 
  172. swappable.
  173.  
  174.  
  175. USING R&R WITH DESQVIEW
  176.  
  177. In order to configure DESQview for R&R, you should be aware of the
  178. following features of R&R: 1) Except for Print Preview, R&R is DESQview
  179. aware. It does not write directly to the screen except when you use the
  180. /Print Preview command. 2) Print Preview is a graphical feature. 3) R&R
  181. supports the use of a math co-processor. 4) R&R can be configured to use 
  182. its own colors. 5) R&R does not use expanded or extended memory. 6) The
  183. R&R serial number controls your access to R&R. When you run R&R 
  184. interactively, the serial number is "locked." It is released by R&R only 
  185. when you /Exit. Any other termination of R&R will cause the serial number 
  186. to remain locked and unavailable for use until you run the RRUSERS program 
  187. to unlock it.
  188.  
  189.  
  190. NEW AND CHANGED ERROR MESSAGES
  191.  
  192. Cannot read...
  193. The "Cannot read (file name)" error messages may also indicate that the
  194. specified file is opened for exclusive use or locked by another user on
  195. the network. Try running your report again later.
  196.  
  197. Cannot Preview current page size:
  198. This new message indicates that R&R is unable to preview your page. Use the
  199. /Print Options Page-Margins command to check your page length, right margin,
  200. and page orientation.
  201.  
  202. Duplicate switch: /(switch):
  203. This new message indicates that the command you have used to install R&R 
  204. specifies the same switch twice. Re-run the installation program, reading 
  205. the installation chapter of the User's Guide and the RRINSTAL instruction 
  206. screen for information about the command line switches.
  207.  
  208. Invalid filter in control file:
  209. This message may also indicate that the RI_FILTER expression in the runtime
  210. control file makes invalid use of totals by referencing a running total or
  211. a pre-processed total that resets at a level other than the highest level
  212. at which a pre-processed total is defined. See the Query chapter for an
  213. explanation of what totals are allowed in queries and RI_FILTER expressions.
  214.  
  215. Invalid value in (field):
  216. This new message indicates that the value in the specified field in the 
  217. runtime control file is too long. See the Runtime chapter of the User's 
  218. Guide for information about the maximum length of runtime control file fields.
  219.  
  220. Cannot read ASCII memo file:
  221. This message has been changed to "Cannot read memo file" since it can apply
  222. to both ASCII and database memo files. If this message occurs when you try
  223. to print a report, R&R is unable to access the memo file (either an ASCII
  224. memo file, a database file with a memo field, or the DBT file that contains
  225. the database memo). See the explanation of the "Cannot read..." error 
  226. messages.