  1.  
  2. ΓòÉΓòÉΓòÉ 1. Description ΓòÉΓòÉΓòÉ
  3.  
  4. UPS Monitor for OS/2 ver. 1.0 - Utility program to monitor the status of the 
  5. APC Uninterruptible Power Sources (UPS). Provides shutdown services to the 
  6. operating system. Includes two programs optimized for most APC-brand UPS 
  7. models. Designed for single workstation environment. 
  8.  
  9. UPS Monitor for OS/2 is shareware and registration is available through BMT 
  10. Micro at www.bmtmicro.com or through the author directly. See the section How 
  11. To Register UPS Monitor for details. 
  12.  
  13. CAUTION if you are using the Back-UPS model (non-Pro version). Please read the 
  14. section Caution - Warning before you use UPS Monitor B (UPSMONB.EXE). 
  15.  
  16. Which executable do I use? 
  17.  
  18. There are currently two versions of the UPS Monitor program available. 
  19. UPSMONS.EXE supports the smart signalling of the Smart-UPS, Smart-UPS v/s and 
  20. the Back-UPS Pro. Matrix-UPS may also be supported, but is untested. This 
  21. program provides support for the features common to all these models. 
  22. Exceptions are restart capabilities and UPS Turn Off Delay which are only 
  23. available on the Back-UPS Pro and Smart-UPS models. These two features are 
  24. available in UPSMONS.EXE. This program requires the cable number 940-0024B or 
  25. 940-0024C to be connect to the UPS. UPSMONS.EXE will not work with the Back-UPS 
  26. models. 
  27.  
  28. UPSMONB.EXE, also referred to as UPS Monitor B, is designed for the Back-UPS 
  29. model only (non-Pro version) and uses simple signalling. This program requires 
  30. the cable number 940-0020B to be connect to all the UPS model. UPSMONB.EXE will 
  31. not work with other models. 
  32.  
  33. If enough interest and support exists for these kinds of programs, I will write 
  34. and include a third program that will fully support the additional features of 
  35. Back-UPS Pro and Smart-UPS models. I may also add a pipe to these programs 
  36. which would make UPS Monitor accessible over a network. 
  37.  
  38.  
  39. ΓòÉΓòÉΓòÉ 2. General Program Operation ΓòÉΓòÉΓòÉ
  40.  
  41. Installation and Configuration. 
  42.  
  43. You must first configure UPS Monitor to recognize the UPS model and the comm 
  44. port it is connected to. Select Options - Settings and select the comm port 
  45. from the controls. Save the settings and select Options - Connect. This will 
  46. connect to the UPS and a message will tell you if it was successful. You are 
  47. all set. If it did not recognize the UPS, see the section on Troubleshooting 
  48. for information. 
  49.  
  50. If you want UPS Monitor to start automatically when your OS/2 system powers up, 
  51. then place a shadow of the executable into the Startup folder (it's located 
  52. under the OS/2 System folder, simply drag and drop the UPSMONB object into the 
  53. Startup folder). 
  54.  
  55. You must also provide the command line parameters to UPSMONS.EXE or UPSMONB.EXE 
  56. for automatic operation. The commands are /Con to automatically connect to the 
  57. UPS and /Min to minimize on start-up. You must provide these commands on the 
  58. Parameters line in the Properties page of Warp 4.0 or Settings page of Warp 
  59. 3.0. To get to that page, right-click on the UPSMON object and click Properties 
  60. or Settings. 
  61.  
  62. Program Operation. 
  63.  
  64. To minimize the program load, UPS Monitor will check the UPS every 4 seconds 
  65. for status. All time settings therefore have a resolution of 4 seconds as well. 
  66. For example, a UPS on Battery alarm in the worst case, may not be detected 
  67. until 4 seconds after the actual power failure. 
  68.  
  69. The UPS Monitor background color changes according to events and settings. If 
  70. UPS Monitor is not connected to the UPS, the background color is light yellow. 
  71.  
  72. During normal operation when the UPS is on-line the background is light green. 
  73.  
  74. If a power failure is detected and the UPS is on battery, the background 
  75. changes to light red. 
  76.  
  77. If UPS Monitor detects a power failure and after the Message Delay expired, the 
  78. program will give itself focus and it will be restored to screen if it had been 
  79. minimized. This will alert you of a possible shutdown. 
  80.  
  81. The UPS Monitor window can be sized and positioned anywhere on the desktop. 
  82. Size and position are saved. 
  83.  
  84. To bring up Help, simply press F1. Help is context sensitive, so if you have 
  85. the Settings window open, help for the settings will pop up. 
  86.  
  87. When UPS Monitor shuts down your system, it will not save any data of the 
  88. applications that are running. It is the applications responsibility to save 
  89. any data. Set your application to auto or timed save if this option is 
  90. available. 
  91.  
  92. The Back-UPS model does not offer built-in turn off delay as other models do 
  93. and thus poses a problem shutting OS/2 down and turning the UPS off. If the UPS 
  94. is on battery and the fixed duration time expired, UPSMONB.EXE will secure the 
  95. file system by issuing a DOSShutdown API call. This does not shutdown the 
  96. Presentation Manager or any other sessions currently running, but all buffers 
  97. get flushed and the system will restart cleanly after power has been restored. 
  98. The UPS will be turned off immediately after the file system has been secured. 
  99. It is possible that the line power may be restored as the file system is being 
  100. secured. In this case, the UPS will not be turned off. The operating system 
  101. appears locked-up and will not respond to inputs. In this case, you must reboot 
  102. the system using ALT-CTRL-DEL or the RESET button on your computer. Not to 
  103. worry, the file system is secured and the system will restart cleanly the next 
  104. time. 
  105.  
  106.  
  107. ΓòÉΓòÉΓòÉ 3. Caution - Warning ΓòÉΓòÉΓòÉ
  108.  
  109. The APC Back-UPS model does not use conventional serial communications, rather 
  110. it uses the serial control lines to report line failure and command the UPS to 
  111. turn off. Always use the cable with the part number 940-0020B. Other cables 
  112. will cause UPSMONB.EXE to report line failure. 
  113.  
  114. Please read the following section carefully. I have discovered the behavior 
  115. listed below on my APC model Back-UPS 400 and assume that all Back-UPS models 
  116. reflect the same behavior. Remember, this only happens when the line power is 
  117. off and the UPS is running on battery. 
  118.  
  119. The Back-UPS (no-Pro) model uses the DTR line (pin 4 on the 9 pin serial 
  120. connector end) of the serial port to receive a signal to turn itself off. If 
  121. DTR is ON and the UPS is running on batteries, it will turn off right away 
  122. without any delay. 
  123.  
  124. Under what circumstances can the UPS turn off unexpectedly? 
  125.  
  126.       Γûá The UPS can turn off if you connect the UPS with any cable to a serial 
  127.       port at the same time a power failure occurs. 
  128.  
  129.       Γûá If the UPS is attached to a serial port with any cable, no Back-UPS 
  130.       specific software is controlling it and the power goes out. 
  131.  
  132.       Γûá When UPS Monitor B is started while UPS is running on battery and DTR 
  133.       was left turned on from a previous program that controlled the serial 
  134.       port. 
  135.  
  136.  To prevent this unexpected turn off, you can do the following: 
  137.  
  138.       Γûá Start UPS Monitor B only when line power is active. 
  139.  
  140.       Γûá Connect 940-0020B serial cable to UPS only when line power is active 
  141.       and then run UPS Monitor B right away. 
  142.  
  143.  UPS Monitor B will turn DTR off whenever it is started. If you don't use the 
  144.  serial port for any other purposes, and UPS Monitor B is used exclusively to 
  145.  monitor the UPS, DTR will remain off and the above problem will never happen. 
  146.  
  147.  The Back-UPS model is not an ideal power backup solution for your OS/2 
  148.  operating system, but if you follow these guidelines, UPS Monitor B will 
  149.  provide the best protection and let's you safely use this UPS model if you 
  150.  have already purchased one. Avoid the Back-UPS model if you are looking at 
  151.  purchasing a new UPS. UPS that provide turn off delays and are using a full 
  152.  serial protocol are better choices. 
  153.  
  154.  
  155. ΓòÉΓòÉΓòÉ 4. Menu Description ΓòÉΓòÉΓòÉ
  156.  
  157. Describes all menu items available for this program. 
  158.  
  159.  
  160. ΓòÉΓòÉΓòÉ 4.1. FILE - Open Log ΓòÉΓòÉΓòÉ
  161.  
  162. Opens a UPS Monitor log file for viewing. This log file is a regular text file 
  163. and can also be opened with any text editor or word processor. 
  164.  
  165. After a log file has been selected, it will show the log in a separate window. 
  166. From this window, you can print or open another log file. You can reposition or 
  167. resize the View Log window. Size and position will be remembered the next time 
  168. you open this window. 
  169.  
  170. Printing is done with the font 6.Helvetica. 
  171.  
  172. Note: The main UPS Monitor window displays the last 10 to 20 events only. If 
  173. more than 20 events are displayed, the oldest 10 events are cut. You can use 
  174. Open Log to view all previous log events. 
  175.  
  176.  
  177. ΓòÉΓòÉΓòÉ 4.2. FILE - Exit ΓòÉΓòÉΓòÉ
  178.  
  179. Exit the program. If the program is still connected to the UPS, the connection 
  180. is terminated. This event is logged. 
  181.  
  182.  
  183. ΓòÉΓòÉΓòÉ 4.3. OPTIONS - Settings ΓòÉΓòÉΓòÉ
  184.  
  185. Opens the UPS Monitor settings window. Set the Com Port (COM1 - COM8) where the 
  186. UPS is connected to, Enable Logging to a file, set the maximum Log File Size 
  187. and set the location and name of the log file. 
  188.  
  189. The log file will be kept approximately within the file size specified. If the 
  190. log file exceeds the selected size, then it is renamed for backup to the same 
  191. name with the extension .000 and a new log is started. If the backup file with 
  192. the extension .000 already exists, then it is replaced. This way it keeps at 
  193. least one log full of data. 
  194.  
  195. The Beep check box enables or disables the audible alarm during program 
  196. operation. The audible alarm will activate whenever a power failure is detected 
  197. and at every subsequent shutdown message interval. The alarm is a short, low to 
  198. high tone beep. 
  199.  
  200.  
  201. ΓòÉΓòÉΓòÉ 4.4. OPTIONS - Shutdown Parameters ΓòÉΓòÉΓòÉ
  202.  
  203. Opens the shutdown parameter window. Set the UPS on Battery message delay (0-99 
  204. secs.) and message interval (0-999 secs.). It is the delay and interval at 
  205. which the UPS Monitor is brought to the foreground to indicate that the UPS is 
  206. running on battery. Select a range that matches your UPS capacity in order to 
  207. get notified on time when the UPS shuts down. Default values are 10 second 
  208. delay and 30 second intervals. 
  209.  
  210. The Back-UPS model does not report low battery through the serial port. 
  211. Shutdown time can only be set to a fixed time. Set Fixed Duration shutdown 
  212. time. In a power fail situation, the UPS Monitor will then shutdown the system 
  213. after the set time has expired. Default value is 60 seconds. Depending on your 
  214. model number, you can set this to a longer value. 
  215.  
  216. The Ext. Shutdown Script check box allows to execute an external script (the 
  217. file UPSMONB.CMD) for shutting the system down. You can customize this file to 
  218. your own liking to shut down OS/2. The external shutdown will not secure the 
  219. file system or turn the UPS off after the fixed time has expired. The UPS will 
  220. simply continue to run until the battery is low and can not regulate the power 
  221. anymore. You will have to shutdown OS/2 with your own script within the 
  222. run-time provided by the battery. Please read General Program Operation for 
  223. more information on how UPS Monitor B shuts down the UPS. 
  224.  
  225.  
  226. ΓòÉΓòÉΓòÉ 4.5. OPTIONS - Connect ΓòÉΓòÉΓòÉ
  227.  
  228. Opens the selected comm port and connects to the UPS. This event is logged. 
  229.  
  230.  
  231. ΓòÉΓòÉΓòÉ 4.6. OPTIONS - Disconnect ΓòÉΓòÉΓòÉ
  232.  
  233. Disconnects from the UPS and closes the comm port. This event is logged. 
  234.  
  235.  
  236. ΓòÉΓòÉΓòÉ 4.7. HELP - Help Index ΓòÉΓòÉΓòÉ
  237.  
  238. Displays this help file (UPSMONB.HLP). 
  239.  
  240.  
  241. ΓòÉΓòÉΓòÉ 4.8. HELP - About ΓòÉΓòÉΓòÉ
  242.  
  243. Product information. 
  244.  
  245.  
  246. ΓòÉΓòÉΓòÉ 5. Simple Signalling Cable Pinout ΓòÉΓòÉΓòÉ
  247.  
  248. Below is a connection diagram to connect the APC UPS to a 25 or 9 pin serial 
  249. port. This cable requires a UPS supporting simple signalling and the 
  250. UPSMONB.EXE program. 
  251.  
  252. Note: Simple signalling UPS models do not exchange serial data through the 
  253. regular pins 2 and 3, rather the status of the UPS is sensed through the CTS 
  254. and DTR control lines. 
  255.  
  256.  
  257. ΓòÉΓòÉΓòÉ 6. Troubleshooting ΓòÉΓòÉΓòÉ
  258.  
  259. If you are having problems connecting to the UPS, then follow these steps 
  260. below. 
  261.  
  262.       Γûá  UPS Monitor is only designed and tested for the APC (American Power 
  263.       Conversion) models Back-UPS, Smart-UPS, Smart-UPS v/s and Back-UPS Pro. 
  264.  
  265.       Γûá  The UPSMONS.EXE executable is only designed to work with models 
  266.       supporting smart signalling like the Smart-UPS, Smart-UPS v/s and 
  267.       Back-UPS Pro. You must use cable number 940-0024B or 940-0024C included 
  268.       with these UPS for proper operation. It is possible that this program 
  269.       will work with other APC models, like the Matrix-UPS, using smart 
  270.       signalling. UPS Monitor has not been tested with the Matrix-UPS model. 
  271.       UPSMONS.EXE will not work with the model Back-UPS (400, 450 and 600) 
  272.       which use simple signalling. Refer to the Help file of UPSMONS.EXE for 
  273.       more information. 
  274.  
  275.       Γûá  The UPSMONB.EXE executable is only designed to work with models 
  276.       supporting simple signalling, like the Back-UPS (non-Pro models). You 
  277.       must use cable number 940-0020B included with this UPS for proper 
  278.       operation. 
  279.  
  280.       Γûá  Next paragraph for UPSMONB.EXE only 
  281.  
  282.       Because of the simple signalling the Back-UPS model uses, you must 
  283.       manually test if communication is working properly. Make sure the Fixed 
  284.       Duration time is set to 60 seconds before doing this test. Connect 
  285.       UPSMONB.EXE (using Options - Connect) to the UPS and if the proper cable 
  286.       is connected to the UPS, you should get the message Connected to UPS Now 
  287.       remove the power from the UPS for 10 seconds and you should get the 
  288.       message Power Failure detected. UPS on battery. This completes the test. 
  289.       If you do not get these messages, the connection to the UPS is not 
  290.       working or you have the wrong cable connected. 
  291.  
  292.       Γûá  When UPSMONB.EXE is started during a power failure and the UPS is 
  293.       running on battery, the UPS may turn off right away. See Caution - 
  294.       Warning before you use UPS Monitor B (UPSMONB.EXE). 
  295.  
  296.       Γûá  UPS Monitor will not work with brands other than APC. 
  297.  
  298.       Γûá  Make sure the Com Port in the Settings window matches the com port you 
  299.       use for the UPS. 
  300.  
  301.       Γûá  Make sure you have all the included files present in your directory. 
  302.  
  303.       Γûá  If you have Ray Gwinn's SIO comm drivers, use the included PMLM (Poor 
  304.       Man's Line Monitor) to monitor the CTS control line status. IF CTS is 
  305.       lower case, then power is on. If CTS is upper case, then the line power 
  306.       is off and the UPS is running on batteries. PMLM will also display the 
  307.       baudrate the port is set to. If it is not 2400 then SIO may be locking 
  308.       the port to another baudrate. See below. 
  309.  
  310.       Γûá  If you are using Ray Gwinn's SIO com drivers, check if the baud rate 
  311.       is locked for the particular com port you are using with the interface. 
  312.       Unlock it so UPS Monitor can change the baud rate to 2400. From the SIO 
  313.       reference, it states: 
  314.  
  315.  
  316.                Locked Baud Rate
  317.  
  318.                Placing a colon and a baud rate following the communications port, eg
  319.                (COM1:38400,3F8,IRQ4), causes the port to be locked at that baud rate.
  320.                No program, OS2 or DOS, is allowed to change the baud rate.
  321.  
  322.       Γûá  Try the standard COM1 or COM2 ports if you have problems with any 
  323.       other com ports like COM3 - COM8. Also, remove any serial cable 
  324.       extensions or adapters and connect the UPS directly to the computer. See 
  325.       the section Simple Signalling Cable Pinout for connector pin-outs. 
  326.  
  327.       Γûá  Try using a different computer or different com port to access the 
  328.       UPS. 
  329.  
  330.  
  331. ΓòÉΓòÉΓòÉ 7. Installation ΓòÉΓòÉΓòÉ
  332.  
  333. Note:  REXX or Object REXX must be installed on your system for this program to 
  334. work. REXX is installed by default, but if you did not install it then run Warp 
  335. installation again and selectively install REXX support. 
  336.  
  337. Unzip all files into a separate directory, I suggest the name UPSMON. 
  338.  
  339. Open an OS/2 Window and change to the directory you just created. Type INSTALL 
  340. and the script will create a UPSMonitor folder on the desktop and fill it with 
  341. all executable programs present in the directory. To start the program, 
  342. double-click on the UPSMONB or UPSMONS object inside the folder. 
  343.  
  344. You must first configure UPS Monitor to recognize the UPS model and the comm 
  345. port it is connected to. Select Options - Settings and select the comm port and 
  346. UPS model from the controls. Save the settings and select Options - Connect. 
  347. This will connect to the UPS and a message will tell you if it was successful. 
  348. You are all set. If it did not recognize the UPS, see the section on 
  349. Troubleshooting for information. 
  350.  
  351. Next paragraph for UPSMONB.EXE only 
  352.  
  353. Because of the simple signalling the Back-UPS model uses, you must manually 
  354. test if communication is working properly. Make sure the Fixed Duration time is 
  355. set to 60 seconds before doing this test. Connect UPSMONB.EXE (using Options - 
  356. Connect) to the UPS and if the proper cable is connected to the UPS, you should 
  357. get the message Connected to UPS. Now remove the power from the UPS for 10 
  358. seconds and you should get the message Power Failure detected. UPS on battery. 
  359. This completes the test. If you do not get these messages, the connection to 
  360. the UPS is not working or you have the wrong cable connected. 
  361.  
  362. If you want UPS Monitor to start automatically when your OS/2 system powers up, 
  363. then place a shadow of the executable into the Startup folder (it's located 
  364. under the OS/2 System folder, simply drag and drop the UPSMON object into the 
  365. Startup folder). 
  366.  
  367. You must also provide the command line parameters to UPSMONS.EXE or UPSMONB.EXE 
  368. for automatic operation. The commands are /Con to automatically connect to the 
  369. UPS and /Min to minimize on start-up. You must provide these commands on the 
  370. Parameters line in the Properties page of Warp 4.0 or Settings page of Warp 
  371. 3.0. To get to that page, right-click on the UPSMON object and click Properties 
  372. or Settings. 
  373.  
  374. Installing this program on your system does not change any of the INI or 
  375. CONFIG.SYS files. 
  376.  
  377. UPS Monitor is only designed and tested for the APC models Back-UPS, Smart-UPS, 
  378. Smart-UPS v/s and Back-UPS Pro. It includes two executable programs and to 
  379. determine which program to use, please read the Description for information. 
  380.  
  381. The following files belong to this program: 
  382.  
  383.        UPSMONB.EXE       The executable program using simple signalling. 
  384.  
  385.        UPSMONS.EXE       The executable program using smart signalling. 
  386.  
  387.        UPSMONB.HLP       The help file for UPSMONB.EXE. 
  388.  
  389.        UPSMONS.HLP       The help for UPSMONS.EXE. 
  390.  
  391.        UPSMONB.INI       Settings file for UPSMONB.EXE. 
  392.  
  393.        UPSMONS.INI       Settings file for UPSMONS.EXE. 
  394.  
  395.        UPSMONB.LOG       Default log file created by UPSMONB.EXE. 
  396.  
  397.        UPSMONS.LOG       Default log file created by UPSMONS.EXE. 
  398.  
  399.        VPUTIL.DLL        Dynamic Link Library required by executables. Packed 
  400.                          for smaller size with LXWARP. 
  401.  
  402.        UPSPMSD.DLL       Dynamic Link Library required by executables. 
  403.  
  404.        RXSI2.DLL         Dynamic Link Library required by executables. 
  405.  
  406.        RXASYNC.DLL       Dynamic Link Library required for serial 
  407.                          communications to the UPS. This library of serial 
  408.                          communications routines is included by permission of 
  409.                          Crucial Applications (Author: Ian Timms, e-mail: 
  410.                          itimms@ariel.ucs.unimelb.edu.au). The entire serial 
  411.                          communications package, including the source code for 
  412.                          RXASYNC, is available at my home page or other major 
  413.                          OS/2 sites by the filename RXASYN20.ZIP. This file has 
  414.                          been packed for smaller size using LXWARP. 
  415.  
  416.        INSTALL.CMD       General installation script for UPS Monitor. 
  417.  
  418.        README.TXT        Program description and installation instructions. 
  419.  
  420.        BMTORDER.TXT      Order form to register UPS Monitor through BMT Micro. 
  421.  
  422.  To remove this program from your system, close the program, delete all your 
  423.  UPS Monitor object or shadow from your desktop or folders and delete all the 
  424.  files listed above. 
  425.  
  426.  
  427. ΓòÉΓòÉΓòÉ 8. The Legal Stuff ΓòÉΓòÉΓòÉ
  428.  
  429. UPS Monitor for OS/2 is shareware and not free. You may use it and try it out 
  430. for 30 days. There are no limitations to the shareware version of UPS Monitor 
  431. other than it will cease to function after 30 days. If you like this program 
  432. and would like to continue using it, you must register to obtain a license. See 
  433. How To Register section on ways to register. 
  434.  
  435. The shareware version of this program may be distributed electronically as long 
  436. as all files are kept together. The shareware version is recognized by the 
  437. title  UPS Monitor for OS/2 - Unregistered in the title bar of the main 
  438. program. 
  439.  
  440. A single registration entitles the owner to use the two executables as 
  441. individual registered programs. Only one copy of each of the executables may be 
  442. run at one time on a computer, in other words, if you have a laptop and a 
  443. desktop, you may copy this program onto both computers but only one instance of 
  444. one of the UPS Monitor programs may be run at one time. If there is a 
  445. possibility that two of the same executable programs may be run at the same 
  446. time, then you must get a second license. You may however use UPSMONS.EXE and 
  447. UPSMONB.EXE together on two separate systems by only having one registration. 
  448.  
  449. The registered version of UPS Monitor may not be distributed in any way. 
  450.  
  451. Quantity discounts start with two licenses, contact the author for more 
  452. information. 
  453.  
  454. Registration gives you many benefits. Besides removing of all restrictions, I 
  455. will provide prompt technical support, implement suggestions to program 
  456. improvements, enhancements and customization (if technically possible). 
  457.  
  458. RXASYNC.DLL, required for serial communications to the UPS, is a library of 
  459. serial communications routines and is included by permission of Crucial 
  460. Applications (Author: Ian Timms, e-mail: itimms@ariel.ucs.unimelb.edu.au). The 
  461. entire serial communications package, including the source code for RXASYNC, is 
  462. available at my home page or other major OS/2 sites by the filename 
  463. RXASYN20.ZIP. This DLL has been packed using LXWARP for smaller size. 
  464.  
  465. UPS Monitor is protected using SecureIt. To get more information on this 
  466. shareware protection program, see http://www.bmtmico.com/catalog/secureit/ 
  467.  
  468. DISCLAIMER 
  469.  
  470. Although this software has been tested and run successfully, the author of UPS 
  471. Monitor for OS/2 is in no way responsible for any damage this program may cause 
  472. to computer equipment. 
  473.  
  474. Any trademarks mentioned in this document belong to their respective owners and 
  475. the author of this program is not connected in any way to these products nor 
  476. does he endorse any of the products mentioned. 
  477.  
  478. TRADEMARKS 
  479.  
  480. APC stands for American Power Conversion. 
  481.  
  482. APC, Back-UPS, Smart-UPS, Smart-UPS v/s, Back-UPS Pro and Matrix-UPS are 
  483. registered trademarks of American Power Conversion. 
  484.  
  485.  
  486. ΓòÉΓòÉΓòÉ 9. How to Register UPS Monitor ΓòÉΓòÉΓòÉ
  487.  
  488. There are two ways you can register UPS Monitor: 
  489.  
  490. Send e-mail to ASchw@worldnet.att.net to request my mailing address. You can 
  491. then send me a check or money order and I will return the registration code. 
  492. The cost is $10.00 using this option. 
  493.  
  494. Register through BMT Micro at www.bmtmicro.com. BMT Micro offers a variety of 
  495. purchasing methods, see the file BMTORDER.TXT for details. You will receive the 
  496. registration code usually within one day. The cost is $15.00 for this option. 
  497.  
  498. Quantity discounts are available. Please e-mail me for details. 
  499.  
  500. A single registration entitles you to use both programs, UPSMONB.EXE and 
  501. UPSMONS.EXE and any new versions of UPS Monitor will always be free to 
  502. registered users. 
  503.  
  504.  
  505. ΓòÉΓòÉΓòÉ 10. Support ΓòÉΓòÉΓòÉ
  506.  
  507. For support for this program, you can contact me directly via e-mail. 
  508.  
  509. My e-mail address: 
  510.  
  511.   ASchw@worldnet.att.net 
  512.  
  513. Visit my home page, "The Warped Code Cellar" at 
  514.  
  515.   http://home.att.net/~ASchw 
  516.  
  517. for other information and applications for OS/2 like HOUSE/2 a home automation 
  518. program using X10 devices, Memory Game and Leave One, two speech navigation 
  519. enabled games. 
  520.  
  521. Monitor my home page regularly for new and upgraded OS/2 programs. This will be 
  522. the place where all programs will be available first. 
  523.  
  524. This program is also available at the following sites: 
  525.  
  526. Internet: 
  527.  