S3 Based Value Point Systems 4/26/94
File:S3VP.fax 4/15/94
S3 Based Value Point Systems
Value Point systems running the S3 drivers flickers and has a
black border around the desktop.
DESCRIPTION OF SYMPTOMS:
After installing SVGA support on Value Point systems monitor
flickers and resolutions greater than 640x480x256 colors
have a 1/2 inch black border around the
desktop.
SUMMARY OF RESOLUTIONS:
Run REFRESH.EXE and set up the system to run in the highest
re-fresh rate that the monitor can handle.
The REFRESH program is located on the DOS CAD disk shipped with
Value Point systems.
DETAILS OF RESOLUTIONS:
1. Run DSPINSTL and set system up for SVGA mode , DO NOT RE-BOOT
2. Open a DOS full screen session
3. Obtain the DOS CAD diskette that was shipped with the Value
Point System
4. Switch to the A: drive
c:> A: <enter>
5. CD to the sub-directory named UTIL
a:> CD UTIL <enter>
6. Run REFRESH.EXE
a:\util:>REFRESH <enter>
7. Select the highest re-fresh rates that the monitor is
capable of (WARNING)
8. Save changes and exit the utility
9. St the c:> run SVGA ON
10. Shut down and re-boot system