  2.      #    (
  3.  X#[#^#a#d#g#
  4. 4-6U7X7[7^7a7d7?
  5. ICause:  This is a generic initialization failure message. If the
  6. IBMTOK.OS2 device driver encounters any errors during initialization,
  7. the specific message related to the error will accompany this generic
  8. message.
  9. Action:  Resolve the specific error message that accompanies this
  10. message.  In addition, ensure that the Protocol Manager device driver,
  11. PROTMAN.OS2, is located in the \IBMCOM directory, and that a DEVICE
  12. statement for PROTMAN.OS2 exists in the CONFIG.SYS file.
  13. ICause:  The parameter displayed was found while processing
  14. the IBM Token-Ring Network Driver section of PROTOCOL.INI.
  15. The parameter is not valid.
  16. Action:  Correct the parameter or remove it from PROTOCOL.INI.
  17. ICause:  The value provided for the parameter is not the
  18. correct type or is not a valid value.
  19. Action:  Change the value for the parameter in PROTOCOL.INI.
  20. ICause:  Conflicting parameter values were found
  21. while processing the IBM Token-Ring Network Driver
  22. section of PROTOCOL.INI.
  23. Action:  Examine the configuration parameters and
  24. correct the conflicting values in PROTOCOL.INI.
  25. ICause:  One of the following conditions has caused this error.
  26. - The logical primary/alternate setting in the PROTOCOL.INI file does
  27. not map to the physical primary/alternate setting.
  28. - The adapter is not responding to a request to start.
  29. - There is no physical adapter in this machine.
  30. Action:  If there is already an adapter in this system, check the
  31. logical primary/alternate setting.  Check the cable and ensure that
  32. the connection to the token-ring network addressable unit (NAU) is
  33. functioning properly.  Then run the hardware diagnostics for the
  34. token-ring adapter to ensure that the adapter and options are correctly
  35. installed.
  36. If there is no adapter in this machine, install a token-ring adapter
  37. or remove the device driver statement from the CONFIG.SYS file.
  38. ICause:  An unexpected error occurred when the program
  39. attempted to open the protocol manager.
  40. Action:  Check the drive and directory to ensure that
  41. the protocol manager is located in the specified path.
  42. ICause:  The IBM Token-Ring Network adapter encountered a wire fault.
  43. Action:
  44. 1. Check and secure all cable connections between your adapter and the
  45. Multistation Access Unit (MSAU).  Correct any related problems and
  46. try the operation again.
  47. 2. If there are no related problems, refer to the documentation that
  48. was shipped with your adapter to run adapter diagnostics; then try
  49. the operation again.
  50. 3. If the problem persists, print or save the LANTRAN.LOG file and
  51. contact your service coordinator.
  52. ICause:  The requested DIR.OPEN.ADAPTER parameter has not allowed enough
  53. receive buffer space in the adapter shared RAM area.
  54. Action:  Reduce the RAM requirements by reconfiguring the parameters
  55. in PROTOCOL.INI.  The parameters that will reduce the space requirements
  56. for the receive buffer are the transmit buffers (if more than 1 is
  57. specified).
  58. ICause:  The node address defined is not valid.
  59. Action:  Specify a valid node address.  Refer to the IBM Token-Ring
  60. network arhitecture reference for node address restrictions.
  61. ICause:  The receive buffer length defined in PROTOCOL.INI is not
  62. valid.  The value specified must be greater than the allowable
  63. minimum, less than the allowable maximum, and a multiple of 8.
  64. Action:  Specify a valid receive buffer length.
  65. ICause:  The adapter transmit buffer length defined in PROTOCOL.INI is not
  66. valid.  The value specified must be greater than the allowable
  67. minimum, less than the allowable maximum, and a multiple of 8.
  68. Action:  Specify a valid adapter transmit buffer length.
  69. ICause:  You are attempting to load more than two Token-Ring Shared Ram
  70. device drivers.
  71. Action:  Use the "Configure LAN transports" utility in LAPS to configure a
  72. maximum of two "IBM Token-Ring Network Adapters" or "Token-Ring Network
  73. Adapters" in any combination.  Also, verify that you are attempting to load no
  74. more than two instances of any combination of IBMTOK.OS2 or TOK.OS2 in your
  75. CONFIG.SYS file.                                                              ECause:  While attempting to open a new Token-Ring adapter
  76. using the autosense configuration option, it was determined that the adapter
  77. was the only station on the ring.  The adapter will not be allowed to open
  78. in order to prevent possible network disruptions.
  79. Action:  Restart the application at a later time, when at least one other
  80. station is on the ring.  As an alternative, reconfigure the adapter for
  81. manual mode, specifying the correct speed of the Token-Ring to which the
  82. adapter is connected, then restart the computer.
  83. ICause:  The adapter was closed because of an unexpected error condition.
  84. Action:  See the message log, LANTRAN.LOG, for additional information
  85. about this error.  The error must be corrected before you can use this
  86. adapter.
  87. ICause:  The IBM Token-Ring Network adapter has either detected a monitor
  88. contention failure or received a beacon frame from the ring.  The
  89. problem may be that your adapter speed is different from the speed
  90. at which the LAN is running.
  91. Action:
  92. 1. Check and secure all cable connections between your adapter and the
  93. Multistation Access Unit (MSAU).  Correct any related problems and
  94. try the operation again.
  95. 2. If there are no related problems, refer to the documentation that
  96. was shipped with your adapter to run adapter diagnostics; then try
  97. the operation again.
  98. 3. If the problem persists, print or save the LANTRAN.LOG file and
  99. contact your service coordinator.
  100. ICause:  A command forcing the adapter to remove itself from the ring was
  101. received.
  102. Action:  Contact your LAN personnel to determine why the REMOVE command
  103. was issued for your machine.
  104. ICause:  The IBM Token-Ring Network adapter has detected a problem
  105. on your local lobe between the adapter and the Multistation Access
  106. Unit (MSAU).
  107. Action:
  108. 1. Check and secure all cable connections between your adapter and the
  109. Multistation Access Unit (MSAU).  Correct any related problems and
  110. try the operation again.
  111. 2. If there are no related problems, refer to the documentation that
  112. was shipped with your adapter to run adapter diagnostics; then try
  113. the operation again.
  114. ICause:  The IBM Token-Ring Network adapter has detected one of the
  115. following open errors while trying to insert into the LAN:
  116. - Ring Failure
  117. - Ring beaconing
  118. - Timeout
  119. Action:
  120. 1. Check and secure all cable connections between your adapter and the
  121. Multistation Access Unit (MSAU).  Correct any related problems and
  122. try the operation again.
  123. 2. If there are no related problems, refer to the documentation that
  124. was shipped with your adapter to run adapter diagnostics; then try
  125. the operation again.
  126. ICause:  The IBM Token-Ring Network adapter has detected one of the
  127. following open errors during the address verification phase of the
  128. adapter open process:
  129. - Signal loss
  130. - Timeout
  131. - Ring failure
  132. - Ring beaconing
  133. - Duplicate node
  134. - REMOVE command received
  135. Action:
  136. 1. Check and secure all cable connections between your adapter and the
  137. Multistation Access Unit (MSAU).  Correct any related problems and
  138. try the operation again.
  139. 2. If there are no related problems, refer to the documentation that
  140. was shipped with your adapter to run adapter diagnostics; then try
  141. the operation again.
  142. ICause:  The IBM Token-Ring Network adapter has detected one of the
  143. following open errors during the roll call poll phase of the adapter
  144. open process:
  145. - Signal loss
  146. - Timeout
  147. - Ring failure
  148. - Ring beaconing
  149. - REMOVE command received
  150. Action:
  151. 1. Check and secure all cable connections between your adapter and the
  152. Multistation Access Unit (MSAU).  Correct any related problems and
  153. try the operation again.
  154. 2. If there are no related problems, refer to the documentation that
  155. was shipped with your adapter to run adapter diagnostics; then try
  156. the operation again.
  157. 3. If the problem persists, print or save the LANTRAN.LOG file and
  158. contact your system coordinator.
  159. ICause:  The IBM Token-Ring Network adapter has detected one of the
  160. following open errors during the request parameter phase of the adapter
  161. open process:
  162. - Signal loss
  163. - Timeout
  164. - Ring failure
  165. - Ring beaconing
  166. - Parameter request
  167. - REMOVE command received
  168. Action:
  169. 1. Check and secure all cable connections between your adapter and the
  170. Multistation Access Unit (MSAU).  Correct any related problems and
  171. try the operation again.
  172. 2. If there are no related problems, refer to the documentation that
  173. was shipped with your adapter to run adapter diagnostics; then try
  174. the operation again.
  175. 3. If the problem persists, print or save the LANTRAN.LOG file and
  176. contact your service coordinator.
  177. ICause:  The IBM Token-Ring Network adapter has detected a lobe media
  178. failure while trying to open the adapter.
  179. Action:
  180. 1. Check and secure all cable connections between your adapter and the
  181. Multistation Access Unit (MSAU).  Correct any related problems and
  182. try the operation again.
  183. 2. If there are no related problems, refer to the documentation that
  184. was shipped with your adapter to run adapter diagnostics; then try
  185. the operation again.
  186. 3. If the problem persists, print or save the LANTRAN.LOG file and
  187. contact your service coordinator.
  188. ICause:  The IBM Token-Ring Network adapter has detected a signal loss
  189. failure while trying to open the adapter.
  190. Action:
  191. 1. Check and secure all cable connections between your adapter and the
  192. Multistation Access Unit (MSAU).  Correct any related problems and
  193. try the operation again.
  194. 2. If there are no related problems, refer to the documentation that
  195. was shipped with your adapter to run adapter diagnostics; then try
  196. the operation again.
  197. 3. If the problem persists, print or save the LANTRAN.LOG file and
  198. contact your service coordinator.
  199. ICause:  The IBM Token-Ring Network adapter has detected that the
  200. ring is operating at a speed other than the speed at which it was inserting.
  201. Action:  Make sure the IBM Token-Ring Network adapter and the ring are set
  202. for the same speed.  If the problem persists, print or save the LANTRAN.LOG
  203. file and contact your service coordinator.
  204. ICause:  The IBM Token-Ring Network adapter has detected an insertion
  205. timer expiration while trying to open the adapter.  This condition
  206. indicates that the ring may be congested, experiencing a high
  207. bit-error rate, or is losing an unusually high number of tokens
  208. or frames.
  209. Action:
  210. 1. Check and secure all cable connections between your adapter and the
  211. Multistation Access Unit (MSAU).  Correct any related problems and
  212. try the operation again.
  213. 2. If there are no related problems, refer to the documentation that
  214. was shipped with your adapter to run adapter diagnostics; then try
  215. the operation again.
  216. 3. If the problem persists, print or save the LANTRAN.LOG file and
  217. contact your service coordinator.
  218. ICause:  The IBM Token-Ring Network adapter has detected a ring failure
  219. while trying to open the adapter.
  220. Action:
  221. 1. Check and secure all cable connections between your adapter and the
  222. Multistation Access Unit (MSAU).  Correct any related problems and
  223. try the operation again.
  224. 2. If there are no related problems, refer to the documentation that
  225. was shipped with your adapter to run adapter diagnostics; then try
  226. the operation again.
  227. 3. If the problem persists, print or save the LANTRAN.LOG file and
  228. contact your service coordinator.
  229. ICause:  The IBM Token-Ring Network adapter has detected a monitor
  230. contention failure or has received a beacon frame from the ring
  231. while trying to open the adapter.
  232. Action:
  233. 1. Check and secure all cable connections between your adapter and the
  234. Multistation Access Unit (MSAU).  Correct any related problems and
  235. try the operation again.
  236. 2. If there are no related problems, refer to the documentation that
  237. was shipped with your adapter to run adapter diagnostics; then try
  238. the operation again.
  239. 3. If the problem persists, print or save the LANTRAN.LOG file and
  240. contact your service coordinator.
  241. ICause:  The IBM Token-Ring Network adapter has detected a that another
  242. station on the ring has an adapter address equal to the address
  243. specified for your adapter.
  244. Action:  Note the identification number of this message and then
  245. contact your system administrator.
  246. ICause:  The IBM Token-Ring Network adapter has detected a parameter
  247. request error while trying to open the adapter.
  248. Action:
  249. 1. Check and secure all cable connections between your adapter and the
  250. Multistation Access Unit (MSAU).  Correct any related problems and
  251. try the operation again.
  252. 2. If there are no related problems, refer to the documentation that
  253. was shipped with your adapter to run adapter diagnostics; then try
  254. the operation again.
  255. 3. If the problem persists, print or save the LANTRAN.LOG file and
  256. contact your service coordinator.
  257. ICause:  While attempting to insert into the ring, a command forcing
  258. this adapter to remove from the ring was received.
  259. Action:  Contact your LAN personnel to determine why the REMOVE command
  260. was issued for your machine.
  261. ICause:  RPL station is the first station attempting to insert onto
  262. the ring.
  263. Action:
  264. 1. Retry the operation.
  265. 2. If the problem persists, refer to the documentation that
  266. was shipped with your adapter to run adapter diagnostics; then try
  267. the operation again.
  268. 3. If the problem persists, print or save the LANTRAN.LOG file and
  269. contact your service coordinator.
  270. ICause:  Physical insertion of RPL station onto the ring failed.
  271. Action:
  272. 1. Check the adapter configuration and retry the open request.
  273. 2. If the problem persists, refer to the documentation that
  274. was shipped with your adapter to run adapter diagnostics; then try
  275. the operation again.
  276. ICause:  A problem was detected on micro-code level "00 00 00 C2 45 50".
  277. Action:  Request and install engineering change ECA0066, part# 92F9122,
  278. on your system, or use the configuration feature of the Lan Adapter
  279. and Protocol Support installation program to change the value for the
  280. number of transmit buffers to be greater than 1.
  281.