LD11PAT Package
Version 1, Fix Module Dates 5/4/94.
This package contains all fixes for LD 1.1. The LD11PAT.ZIP
file contains 4 zip files:
LD11ADV.ZIP : LD 1.1 Advanced Connection Server Fixes.
LD11ENT.ZIP : LD 1.1 Entry Connection Server Fixes.
LD11OS2R.ZIP : LD 1.1 OS/2 Remote Workstation Fixes.
LD11WINR.ZIP : LD 1.1 Windows Remote Workstation Fixes.
There is a .TXT file for each zip file which contains
instructions on how to install the fixes and which APARs
are fixed by the zip file. Please read the .TXT files
carefully to see whether fixes are required on the remote
workstation only, the connection server only or on the
remote workstation and the connection server.
Note that the LD11ADV.ZIP and LD11ENT.ZIP files are different
and must be applied to the correct version of the connection
server.
THE FOLLOWING IS A SUMMARY OF FIXES PROVIDED IN THE PACKAGE.
APAR: IC07600
SYMPTOMS:
Callback from the connection server to the remote workstation
fails when automatic filtering has been enabled on the connection
server.
SOLUTION:
LAN Distance has been changed to activate automatic filtering
in the callback sequence. For this problem, only the connection
server needs to be updated.
APAR: IC07598
SYMPTOMS:
Support for X.25 native adapters
SOLUTION:
Changes where made to LAN Distance in order to support adpaters that
support native X.25. If this support is required, then the patch
needs to be applied to the connection server and the OS/2 remote
workstations using the X.25 native adapter.
APAR: IC07599
SYMPTOMS:
Support for the IBM ISDN Primary Rate Adapter
SOLUTION:
Support has been added to LAN distance to allow the use of the
ISDN Primary Rate Adapter. This fix must be applied to all
workstations using the adapter, connection servers and remote
workstations.
APAR: IC07601
SYMPTOMS:
Banyan Vines OS/2 client cannot connect to a Banyan server over
LAN Distance when the LAN is token ring.
SOLUTION:
The Banyan Vines protocol stack does not set the source address
field in the token ring frame. LAN Distance now fills in the
address.
APAR: IC07457
SYMPTOMS:
Windows remote workstation receives blank screen, hangs or exits to
DOS when a LAN Distance connection is being established.
SOLUTION:
When a windows remote workstation connects to the connection server,
the windows workstation may get a blank screen, hang, or exit to
DOS. This problem occurs more frequently when there is not sufficient
filtering (automatic filtering not enabled at the connection server).
This problem occurs more frequently on Ethernet LANs.