IFault Tolerance Device Driver, Version 3.0
(c) IBM Corporation, 1991, 1992
(c) Microsoft Corporation, 1989, 1990
E There is not enough memory for the Fault Tolerance driver
to build the internal structures.
EFault Tolerance could not attach to the disk device driver.
EFault Tolerance received an incorrect response from the disk
device driver.
EThe disk device driver does not support Fault Tolerance.
EThe versions of the disk device driver and the
Fault Tolerance device driver are not compatible.
EFault Tolerance detected a disk device driver that is not valid .
EThe disk partition limit of 24 entries was exceeded.
EThe Fault Tolerance system could not allocate global
descriptor table entries.
E Warning: The Fault Tolerance driver failed to initialize.
EThe Fault Tolerance driver encountered an error while parsing the
DEVICE=path\DISKFT.SYS command line in CONFIG.SYS.
I Default values are being used.
IFault Tolerance Error Monitor, version 3.0.
(c) IBM Corporation, 1991, 1992
(c) Microsoft Corporation, 1989, 1990
EThe Fault Tolerance device driver could not be opened.
EThere is not enough memory to create \\SHARMEM\\FTMONIT.
EIncorrect options have been used to start FTMONIT.
IValid options for FTMONIT are:
/Alert:[Yes]|[No]
Specifies whether alerts are to be sent to users specified by the
alertnames parameter in the Server section of IBMLAN.INI.
/Alert:Yes is the default.
/Compare:[Yes]|[No]
Specifies whether to do a low-confidence comparison at startup.
This parameter is ignored if FTMONIT has already been started.
/Compare:Yes is the default.
/Verify:[Yes]|[No]
Specifies whether FTMONIT should attempt to do required drive Verifies.
This parameter is ignored if FTMONIT has already been started.
/Verify:Yes is the default.
/Quiet:[Yes]|[No]
Prevents display of messages on the screen. This option is ignored
when starting FTMONIT from CONFIG.SYS (no message is ever displayed
in this case). /Quiet:No is the default.
/Clear:[Yes]|[No]
Clears all statistics counters maintained by the Fault Tolerance driver.
/Clear:No is the default.
EThe file FT.DLL could not be found.
INELOG_DiskFT
IMIRRORING
IDISKFT Monitor
IAlert
ICompare
IQuiet
IClear
IError
ICritical
IThe Fault Tolerance Monitor (FTMONIT) is verifying drive %c.
WFault Tolerance error 001 has occurred:
A write to the primary partition failed.
A write to the alternate partition succeeded.
WFault Tolerance error 002 has occurred:
A write to the primary partition succeeded.
A write to the alternate partition failed.
WFault Tolerance error 003 has occurred:
A read from the primary partition failed.
A read was recovered from the secondary partition.
WFault Tolerance error 004 has occurred:
A read from the secondary partition failed.
A read was recovered from the primary partition.
WFault Tolerance error 005 has occurred:
A write to the primary partition and the secondary partition failed.
WFault Tolerance error 006 has occurred:
A write to a non-mirrored drive failed.
WFault Tolerance error 101 has occurred:
A read from a non-mirrored drive failed.
WFault Tolerance error 102 has occurred:
A read from the primary partition and the secondary partition failed.
WFault Tolerance error 103 has occurred:
An excessive failure rate was detected on the primary partition of a drive.
Read requests will be routed to the secondary partition.
WFault Tolerance error 104 has occurred:
An excessive failure rate was detected on the secondary partition of a drive.
Read requests will be routed to the primary partition.
WFault Tolerance error 105 has occurred:
The primary partition of a drive was shut down because of complete failure.
All requests will be routed to the secondary partition.
WFault Tolerance error 106 has occurred:
The secondary partition of a drive was shut down because of complete failure.
All requests will be routed to the primary partition.
WFault Tolerance error 107 has occurred:
A low-confidence comparison of mirrored partitions for a drive failed.
All read requests will be routed to the primary partition.
WFault Tolerance error 108 has occurred:
A complete comparison of mirrored partitions failed. All read
requests will be routed to the primary partition.
WFault Tolerance error 109 has occurred:
A low-confidence comparison of mirrored partitions for a drive failed.
All read requests will be routed to the secondary partition.
EFault Tolerance critical error 201 has occurred:
An excessive error rate was detected on a non-mirrored drive.
An alternate partition is not available.
EFault Tolerance critical error 202 has occurred:
A complete failure was detected on a drive. An alternate partition
is not available.
EFault Tolerance critical error 209 has occurred:
The secondary partition of a mirrored drive was not found.
EFault Tolerance critical error 210 has occurred:
A secondary partition with no matching primary was found.
EFault Tolerance critical error 211 has occurred:
Error logging has been interrupted. One or more errors may have been lost.
EFault Tolerance critical error 212 has occurred:
Error logging was not completed. One or more errors may not have been
logged for the following drives: