ΓòÉΓòÉΓòÉ 1. Using Command Line Parameters ΓòÉΓòÉΓòÉ
The user can enter the parameters at the command prompt following the
INSTALL.EXE, the EPFIDLDS.EXE or the EPFINSTS.EXE file. The information passed
as values of these parameters is used by EPFINSTS.EXE during installation
processing.
You should document how to use these parameters if your users install your
product differently from what you specified in your IIRC.RC resource file. Or,
you can supply a command file to the user with the necessary parameters.
If no parameters are specified when the executable file is started, the
installation is attended. To install in an unattended mode, the /X parameter
must be used. Unattended includes what is sometimes referred to as lightly
attended. In the lightly attended mode, someone might have to start an
executable file or insert diskettes.
If the value of any of the parameters contains spaces, use double quotes to
enclose the value.
Values can be upper or lower case. Parameters can be in any order.
<command> /A:<action>
/C:<catalog file name>
/G:<include path>
/L:<xpos,ypos>
/L1:<error log>
/L2:<history log>
/L3:<log file>
/L4:<log file>
/L5:<log file>
/NMSG
/O:<originating system>
/P:<product name>
/R:<response file>
/S:<source location>
/T:<install target directory>
/TU:<update CONFIG.SYS directory>
/X <interactive_flag>
The /A, /C, and /P parameters are required for an installation that is started
with the EPFINSTS command. If the action is an install or an update, the /O is
also required. The /A, /C, /L, /O, /P, /R, and /S parameters override values
you have set in the IIRC.RC.
Note: The drive/directory/filename path is required for all log parameters
specified with the INSTALL.EXE or EPFIDLDS.EXE commands. The directories for L1
and L2 log files will be created if they do not exist. The directories for all
other log files must exist before starting the commands.
ΓòÉΓòÉΓòÉ 2. Parameter Definitions ΓòÉΓòÉΓòÉ
The command prompt parameters are:
/A:<action>
Specifies the action of the EPFINSTS.EXE.
If you use this parameter, the main window of the installation is not
displayed.
If you do not use this parameter, the installation starts normally with all
windows displayed.
Valid values for this parameter are:
'D' For delete
'I' For install
'R' For restore
'U' For update
Software Installer sets the EPFIACTION installation variable to the action.
/C:<catalog file name>
Specifies the name and location of the catalog file that you want to be
opened automatically.
If the catalog file is located on a host session, the host session ID must
precede the catalog file name. If the catalog file is located on a drive, a
drive and directory must precede the catalog file name.
Software Installer sets the EPFICATALOG installation variable to the name of
the catalog file.
The following examples show how to use this parameter for each installation
source.
o For Drive: /C:A:\DISK1.ICF
o For MVS: /C:B:EPF.V1R2M0.SEPFBENU(EPFICAT)
o For VM: /C:"B:EPFICAT ENUEPF12 *"
o For VSE: /C:B:LIB.SUBLIB.MEMBERNAME.MEMBERTYPE
If only the host session ID is specified, for example, B: then the Open
catalog window is displayed with B: as the default session or drive.
/G:<include path>
Specifies the drive and directory of the general response files that are
included by the specific response file.
Software Installer sets the EPFIGENRESPDIR installation variable to the
included path.
Example:
/G:L:\XYZ
/L:<xpos,ypos>
Specifies the initial horizontal and vertical coordinates of the initial
installation window on the Workplace Shell* relative to the lower-left
corner of the screen.
If this parameter is specified, all previously saved default positions are
overridden.
Software Installer sets the EPFIWNDCOORDS installation variable to the
coordinates of the Installation and Maintenance window.
/L1:<error log>
Specifies the drive, path, and file name of the error log file.
Software Installer sets the EPFIERRORLOG installation variable to the name
of the error log.
Note: The drive/directory/filename path is required. The directory for the
log file must already exist.
All lines logged to the error file are prefixed with a time stamp. The time
stamp has the following format:
YYYY-MM-DD HH:mm:SS:cc
Where:
YYYY is the year.
MM is the month.
DD is the day.
HH is the hour.
mm is the minute.
SS is the second.
cc is the hundredth of a second.
The date and time separators are the current user-defined settings in the
Country object of the System Settings folder. The default separators are the
hyphen and the colon, respectively.
Example of using the /L1 parameter to create ERROR.LOG file in the C:\ABC\
directory:
/L1:C:\ABC\ERROR.LOG
/L2:<history log>
Specifies the drive, path, and file name of the history log file. Software
Installer sets the EPFIHISTORYLOG installation variable to the name of the
history log.
Note: The drive/directory/filename path is required. The directory for the
log file must already exist.
If this parameter is not specified, no history log is maintained.
All lines logged to the history file are prefixed with a time stamp. The
time stamp has the following format:
YYYY-MM-DD HH:mm:SS:cc
Where:
YYYY is the year.
MM is the month.
DD is the day.
HH is the hour.
mm is the minute.
SS is the second.
cc is the hundredth of a second.
The date and time separators are the current user-defined settings in the
Country object of the System Settings folder. The default separators are the
hyphen and the colon, respectively.
Example of using the /L2 parameter to create HISTORY.LOG file in the C:\ABC\
directory:
/L2:C:\ABC\HISTORY.LOG
/L3: /L4: /L5:<log files>
Each of these parameters specifies a drive, path, and file name of a log
file. They are saved in installation variables EPFIL3LOG, EPFIL4LOG, and
EPFIL5LOG for your use.
Note: The drive/directory/filename path is required. The directories for
the log files must already exist.
/NMSG
Specifies that the ending message will not be displayed.
/O:<originating system>
Specifies the originating system of the installation. Valid values are:
o DRIVE
o MVS
o VM
o VSE
Software Installer sets the EPFISOURCE installation variable to one of these
values.
/P:<product name>
Provides the name of the product for the specified action.
If you do not use this parameter, the installation comes up normally with
all windows displayed.
The <product name> should match the value of the NAME keyword of the PACKAGE
entry in the catalog file. If your product name string includes any spaces,
use double quotes around the string. For example:
/p:"product name with spaces"
Software Installer sets the EPFIPRODUCT installation variable to the name of
the product.
/R:<response file>
Specifies the drive, path, and file name of the specific response file.
The following search order is used to find the response files.
1. The fully-qualified file specification
2. The current directory. The current directory is the temporary directory
where epfinsts.exe is running. The response file can be placed in the
current directory by packing it in INSTALL.IN_.
3. The file name together with the /G: invocation parameter
4. Each directory in the PATH environment variable
5. Each directory in the DPATH environment variable
Software Installer sets the EPFIRESPFILE installation variable to the
response file.
Example:
/R:L:\XYZ\RESPONSE.DAT
/S:<source_location>
Specifies the drive and path that contains the source files to install.
Software Installer sets the EPFISOURCEDIR installation variable to the
source_location.
Specifying this parameter overrides the value of the HOSTLOC keyword in the
product's catalog file PACKAGE entry.
If this parameter is not specified, the value of the HOSTLOC keyword is not
overridden.
Example:
/S:L:\XYZ
/T:<install target directory>
Specifies the drive and path where the product files are installed.
This parameter only affects the value of the FILE directory (directory
corresponding to the FILELABEL keyword). If this parameter is specified, it
overrides the FILE paths that are specified in the response files and the
package files.
Software Installer sets the EPFITARGETDIR installation variable to the
install target directory.
Example:
/T:C:\IBB
/TU:<update target CONFIG.SYS directory>
Specifies the drive and path of the target CONFIG.SYS to be updated.
Software Installer sets the EPFITARGETCNF installation variable to the
update CONFIG.SYS target directory.
If this parameter is not specified, the CONFIG.SYS files are updated as
specified in the product's package file.
Example:
/TU:C:\
/X
Specifies that the action is unattended.
If you do not specify all of the information needed for the action to
complete, an error occurs. When you specify the /X option, no progress
indication is shown and all error messages are logged to the error file you
specified using the /L1 parameter.
If you do not specify this option, the user is prompted for any information
that the EPFINSTS.EXE needs to complete the action. In this attended mode of
action, progress indication is shown and error messages are displayed to the
user in secondary windows.
Software Installer sets the EPFINONINTERACT installation variable to YES if
the /X parameter is specified.