IDaemon ConfigurationIMessage TimeoutIPress <Esc> to continueI: I
EAn error occurred during attempt to get shared memory.EAn error occurred during attempt to allocate a shared segment.EThe daemon cannot access the Link Support Layer. Error: %1.EThe DDAEMON is already loaded.E
INetWare for OS/2 v2.01
IPROTOCOL OPTION: Novell IPX
I(C) Copyright 1988, 1992 Novell, Inc. All Rights Reserved.
EThe system does not have enough memory for for socket tables.EThe LAN support module could not be installed.EThe IPX MLID could not be installed.EThe configured LAN-A driver does not support IPX.EThe IPX protocol handler cannot be registered.EThe IPX entry point cannot be initialized.EAn internal error occurred. The IPX router socket cannot be opened.EAn internal error occurred. A router selector cannot be allocated.EThe system has insufficient memory to allocate a router.ERouter memory is exhausted.EAn internal error prevented CGroup variable initialization. some internal variables.
EAn internal error prevented DosHlp variable initialization.EIPX cannot register with OS/2 for PDD-to-VDD communications.EThe IPX device driver is not running.I
WThe default protocol configuration option is not used for IPX.WThe prescan protocol configuration option is not used for IPX.WThe OS/2 version number cannot be found; OS/2 v2.0 is assumed.I
I Sockets: %1
I Router Memory: %1
INetWare for OS/2 v2.01
INovell Link Support Layer
I(C) Copyright 1988, 1992 Novell, Inc. All Rights Reserved.
EAn LSL error occurred. NET.CFG buffers are too big for ECB pool.EThe Link Support module (LSL) could not install the AES timer.EThe Link Support module could not initialize its call gate.
ILink SupportIBuffersIMem PoolI
I Buffers : %1
I Buffer Size: %1
I Total Memory Allocated for Buffers: %1
INetWare for OS/2 v2.01
INovell NetBIOS Emulator
I(C) Copyright 1988, 1992 Novell, Inc. All Rights Reserved.
ENetBIOS error occurred. Link Support module cannot be installed.ENetBIOS error occurred. The IPX module is not installed.EThe NetBIOS call gate cannot be initialized.ENetBIOS error occurred. The program cannot initialize local NCBs.ENetBIOS emulator parameters are too large for the memory pool.EIncompatible versions of OS/2 and NetBIOS are running.INetware NetBiosISessionsISend BuffersIRetry DelayIAbort TimeoutIVerify TimeoutIListen TimeoutIRetry CountICommandsIBroadcast DelayIBroadcast CountIInternetIOffIOnINamesI
INetWare for OS/2 v2.01
INovell Remote Named Pipes Driver
I(C) Copyright 1990, 1991 Novell, Inc. All Rights Reserved.
EThe SPX module is not installed.EThe IPX module is not installed.E
EAn incorrect OS/2 version is being used.EThe driver cannot register the PDD for VDD-to-PDD communications.I
INamed PipesIClient SessionsI
INamed PipesI
IDaemon ConfigurationIMessage TimeoutI
IService ThreadsIPress <Esc> to continue.INPDAEMON: EInvalid characters were specified in COMPUTERNAME.EAn error occurred during attempt to initialize NPCALLS.DLL.EThe Named Pipes daemon could not be registered. Error: %1.EAn error occurred during attempt to allocate shared memory.EAn error occurred during attempt to allocate the ECB pool.EAn error occurred during attempt to create a system semaphore.EAn error occurred during attempt to create a thread.EA dynamic socket could not be opened. Error: %1.EA well-known socket could not be opened. Error: %1.EThe NPDaemon cannot get the internet address. Error: %1.EThe NPDaemon cannot get the local target. Error: %1.EThe service advertising function failed. Error: %1.EThe broadcast socket cannot be opened. Error: %1.EAn error occurred during attempt to get code page information.E
EMemory cannot be allocated for turbo buffers.EA connection thread died abnormally. Error: %1.EThe specified computer name is already registered on the internet.EThe receive buffer manager died abnormally. Error: %1.EAn error occurred checking for nondedicated server.EAn error occurred allocating memory for nondedicated SAP buffer.EThe NPDaemon could not obtain a server list.E
INetWare for OS/2 v2.01
INovell Named Pipes Server
I(C) Copyright 1991 Novell, Inc. All Rights Reserved.
EThe SPX module is not installed.EThe IPX module is not installed.E
EAn incorrect OS/2 version is being used.E
INamed PipesIServer SessionsI
IDaemon ConfigurationIMessage TimeoutIMessage via serverIPress <Esc> to continueI
EThe program cannot get code page information. Error: %1.EThe Requester device driver and daemon are incompatible versions.EThe worker DLL cannot be registered. Error: %1.EThe broadcast handler cannot be registered. Error: %1.EThe program cannot get system information. Error: %1.EThe janitor thread priority cannot be set. Error: %1.EThe janitor daemon cannot be registered. Error: %1.EThe program cannot get the current drive map. Error: %1.EThe program cannot set the current drive map. Error: %1.EThe program cannot get the connection ID. Error: %1.EAn error occurred during attempt to initialize the cache.EThe daemon could not boost the thread priority.EThe daemon could not register the DosBox handler.E
ENot enough memory for diagnostic daemon. Error: %1.EThe diagnostic daemon cannot be started. Error: %1.EThe diagnostic daemon priority cannot be changed. Error: %1.ENot enough system memory to start a new thread. Error: %1.EThe SPX send thread cannot be started. Error: %1.EThe SPX receive thread cannot be started. Error: %1.EThe SFT 3 handler cannot be registered.EPacket Burst cannot be initialized.E
ENot enough memory for a network management thread (%1).EA named pipe cannot be started for network management (%1).ENot enough system memory to run network management (%1).E
INetWare for OS/2 v2.01
INovell IFS Requester v2.0
I(C) Copyright 1988, 1991 Novell, Inc. All Rights Reserved.
EThe NWREQ.SYS driver is not loaded.E
EThe program cannot allocate selectors for the workspace table.EThe program cannot allocate memory for the workspace table.E
EMemory is not available for the cache table. Caching is disabled.E
EAn incorrect OS/2 version is being used.E
INetWare RequesterICache BuffersI
ICompatibilityEThe Requester driver version does not match the IFS version.E
INetWare for OS/2 v2.01
INovell IFS Driver v2.0
I(C) Copyright 1988, 1991 Novell, Inc. All Rights Reserved.
IPatent Pending.
EThe LAN support module is not installed.E
WA NetWare server cannot be found.I
EThe program cannot allocate selectors for the connection table.EThe program cannot allocate memory for the connection table.E
EAn incorrect OS/2 version is being used.E
WThe config file cannot be parsed. Default parameters will be used.EAn unrecoverable error occurred. The driver was not loaded.E
EThe program cannot allocate selectors for worker support.I Connections: %1 connections
I Retry count: %1 retries
IConfigured for a nondedicated NetWare file server.
IDisplayHardErrorsEThe program cannot allocate memory for the error message buffer.EThe Requester could not send to server %1 as %2.EThe Requester timed out waiting for reply from server %1.EServer %1 did not respond to a request.EConnection to NetWare server %1 as %2 is now invalid.ERouting to NetWare server %1 has been disrupted.E
ERouting to NetWare server %1 has been disrupted.INonded ServerIDirectory Services OffIName ContextIPacket Burst OffISignature LevelIPreferred TreeILarge Internet Packets OffE
IDaemon ConfigurationIMessage TimeoutIPress <Esc> to continueI
EThe SPDaemon cannot get the SPX version. Error: %1.EThe SPX driver and the SPX daemon are incompatible versions.EThe SPX driver entry cannot be obtained. Error: %1.EThe SPX daemon is already loaded. Error: %1.EThe daemon cannot register with the SPX driver. Error: %1.EThe SPX device handle cannot be closed. Error: %1.EThe SPDaemon cannot wait on semaphore. Error: %1.ESystem information segments cannot be obtained. Error: %1.EPriority for the lock thread cannot be set. Error: %1.EThe SPX driver cannot be accessed. Error: %1.EPriority for an AES thread cannot be set. Error: %1.EPriority for a watchdog thread cannot be set. Error: %1.EPriority for a session thread cannot be set. Error: %1.EThe SPXCALLS.DLL cannot register with the SPX driver.E
INetWare for OS/2 v2.01
IPROTOCOL OPTION: Novell SPX
I(C) Copyright 1988, 1991 Novell, Inc. All Rights Reserved.
EThe driver cannot initialize the CGroup Data variables.EThe driver cannot configure SPX.EThe driver failed to get support hooks from the LSL or IPX.EThe OS/2 version cannot be obtained; OS/2 v2.0 is assumed.EThe driver cannot get OS/2 DOS variables.EThe driver cannot initialize the SPX call gate.EThe driver cannot allocate memory for SPX use.E