home *** CD-ROM | disk | FTP | other *** search
/ swCHIP 1991 January / swCHIP_95-1.bin / utility / cbwlite / readme.txt < prev   
Text File  |  1995-12-09  |  19KB  |  326 lines

  1. Colorado Backup for Windows /Lite Edition
  2. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  3.  
  4. To install CBWLITE, please follow the following steps:
  5.  
  6. 1) Download CBWLITE.ZIP (or CBWLITE.EXE) to a directory
  7.    called CMS.
  8.  
  9. 2) Run PKUNZIP or type CBWLITE to decompress the files.
  10.  
  11. Note:  Error 7AF  
  12.          You cannot install CBWLITE from C: to C:.
  13.          The install files MUST be on a different Drive.
  14.           Please see Step (3) for an explanation.
  15.  
  16. 3) If you have only one partition, for example C:, then
  17.    you must copy the decompressed files to either a Floppy
  18.    disk or create a SUBSTituted drive (For Advanced users only).
  19.  
  20. *** We recommend uncompressing the archive to a floppy.
  21.         For example, PKUNZIP cbwlite.zip a:\
  22.  
  23.    Below is the DOS reference on how to create a SUBST drive.
  24.  
  25. ------------------------------------------------------------
  26. SUBST
  27. Associates a path with a drive letter.
  28. The drive letter you assign represents a virtual drive, 
  29. because you can use the drive letter in commands as if it 
  30. were a physical drive. Do not use the SUBST command when you 
  31. are running Windows.
  32. Syntax
  33.     SUBST [drive1: [drive2:]path]
  34.     SUBST drive1: /D
  35.  
  36.     SUBST d: c:\CMS    
  37.  
  38. To display the names of the virtual drives in effect, use the following
  39. syntax:
  40.     SUBST
  41. Parameters
  42. drive1:
  43.     Specifies the virtual drive to which you want to assign a path.
  44. drive2:
  45.     Specifies the physical drive that contains the specified path (if
  46.     different from the current drive).
  47. path
  48.     Specifies the path that you want to assign to a virtual drive.
  49. Switch
  50. /D
  51.    Deletes a virtual drive.
  52.  
  53. Related Command
  54.  
  55. For information about increasing the number of available drive letters,
  56. see the <LASTDRIVE> command.
  57. ------------------------------------------------------------------------
  58.  
  59. 4) If you have multiple partitions, Please copy the 
  60.    decompressed files to another drive.
  61.  
  62. 5) Run install.exe from within Windows.
  63.  
  64.  
  65. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  66.  
  67.  
  68. Colorado Backup for Windows Troubleshooting
  69. Version 1.10                 Revision 1.10d
  70.  
  71. Contents             
  72. 1.0  Additional Information.
  73. 1.1      Sound Boards.
  74. 1.2      Fax Modems and Voice Mail Systems
  75. 1.3      Third Party Windows Backup Software.
  76. 2.0  Trouble Shooting.
  77. 2.1      General Protection Fault.
  78. 3.0  Performance Tips.
  79. 3.1      Video Drivers.
  80. 3.2      Operating CBW in the background.
  81. 3.3      Memory and Resources.
  82. 4.0  Considerations for Network Users
  83. 5.0  General Trouble Shooting Hints
  84.  
  85.  
  86. 1.0  Additional Information.
  87. 1.1  Sound Boards
  88.      Using a sound board with CBW may require special consideration
  89.      to avoid interrupt and DMA conflicts.  This is particularly
  90.      true when dealing with the Trakker tape drive unit.  Most
  91.      sound boards use an interrupt that corresponds with a parallel
  92.      port.  If a Trakker unit is connected to one of these parallel
  93.      ports, you may have poor sound quality and system lockups.To correct 
  94.      this, choose an interrupt for the sound board that is different from
  95.      your parallel port.  See your sound board's documentation for
  96.      instructions.
  97.      
  98.      Some sound boards install device drivers that conflict with
  99.      CBW's device driver, CMSWTAPE.386.  These sound board device
  100.      drivers install MIDI support.  If you are experiencing
  101.      problems with CBW, you might have a conflict with these MIDI
  102.      drivers.  To correct this, you can remove the MIDI support
  103.      from the Drivers entry in the Control Panel in Windows.  See
  104.      your sound board's documentation for instructions.
  105.  
  106. 1.2  Fax Modems and Voice Mail Systems.
  107.      Some fax modems and voice mail systems install device drivers
  108.      under Windows that may conflict with CBW.  Symptoms of this
  109.      problem include having the tape backup software produce an
  110.      error message when a fax or voice mail is received.  To
  111.      correct this, disable the fax or voice mail reception either
  112.      through the control panel or through the control program for
  113.      your board.
  114.  
  115.  
  116. 1.3  Third Party Windows Backup Software.
  117.      Most third party backup programs for Windows install a device
  118.      driver that conflicts with the CBW driver.  If any other
  119.      backup software has been installed through Windows, you may
  120.      need to remove these drivers before CBW will operate.  To do
  121.      this, you will need to edit the SYSTEM.INI file in your
  122.      Windows directory.  Under the section [386enh] you should see
  123.      several lines that read 'DEVICE='.  If any of these lines reference
  124.      'VIRWT.386', 'VITD.386', 'MYBACKUP.386',  'VFINTD.386',  
  125.      'CPBVXD.386', or 'FASTBACK.386', you  will need to add  a                                       
  126.      semicolon to the beginning of these lines. Common symptoms of a 
  127.      drive conflict are error 61B or lockups.
  128.  
  129. 2.0  Troubleshooting.
  130. 2.1  General Protection Fault.
  131.      In some situations, CBW may fail with a message indicating
  132.      that a General Protection Fault was detected.  In situations
  133.      like this, the most common cause is having a parameter of the
  134.      EMM386.EXE device driver not properly set.  To check for this
  135.      situation, edit the CONFIG.SYS file and place a remark, REM
  136.      before the DEVICE=EMM386.EXE line.  Next, reboot the computer
  137.      and retry the CBW operation.  If the error no longer occurs,
  138.      it is an indication that one of the parameters of the
  139.      EMM386.EXE line is conflicting.  Try removing parameters one
  140.      at a time until the conflicting paramter is located.  The Dos
  141.      manual contains an explanation of the EMM386.EXE and its
  142.      parameters.
  143.  
  144.      If the error persists, or if you do not have a line with
  145.      EMM386.EXE, then we need to check for a device driver conflict
  146.      as stated in section 1.3.  Occasionally device driver
  147.      conflicts can cause a General Protection Fault.
  148.  
  149. 3.0  Performance Tips
  150. 3.1  Video Drivers
  151.      Some systems may experience slow backup speeds.  On these
  152.      systems, improvements may be gained by changing from the
  153.      default VGA driver to the driver supplied with the video
  154.      board.  To determine if this is the problem, start a backup,
  155.      then minimize the CBW window.  It is normal for backup speeds
  156.      to improve somewhat with CBW minimized, however, if the
  157.      results are extreme it may be necessary to change the video
  158.      driver.  See the video board manual for instructions.
  159.  
  160. 3.2  Operating CBW in the background.
  161.      While CBW is capable of running on a system in the background,
  162.      performance may decline with each additional application
  163.      running.  Memory is used by each application which could cause
  164.      CBW to fail with an out of memory error.
  165.      
  166.      When running a backup operation in the background, some open
  167.      files may not back up.     
  168.  
  169.      For fastest performance and to assure a complete backup, you
  170.      may wish to operate CBW as the only application open on the
  171.      system.  
  172.  
  173. 3.3  Memory and Resources.
  174.      If you do not have sufficient memory or resources to execute
  175.      CBW you will receive an error message.  However, having less
  176.      than 2.5M of  available memory or less than 70% resources may
  177.      result in slow performance.  If this is the case, you can
  178.      improve performance by making more memory or more resources
  179.      available to CBW.  
  180.  
  181.      To check your available memory, choose Help from the Program
  182.      Manager, and then choose About Program Manager.  This screen
  183.      will provide you with the amount of memory and system
  184.      resources available.
  185.  
  186.      To make more memory and resources available, you may need to
  187.      close other applications, minimize Program Manager, add more RAM,
  188.      or increase the size of your permanent/temporary swap file.
  189.  
  190. 4.0  Considerations for Network Users.
  191.      Generally CBW works transparently with Windows for Workgroups,
  192.      NetWare Lite and Lantastic, however, with the current version
  193.      of CBW, specific file attributes, bindery and privilege
  194.      information will not be saved.  Please refer to the Networks
  195.      Applications section of the manual for more information.
  196.  
  197.      In the Windows for Workgroups environment, if a "Sharing
  198.      Buffers Exceeded" message occurs try the following changes: 
  199.      In the [386enh] section of the SYSTEM.INI increase
  200.      NetHeapSize= to 48 and DMABufferSize= to 064.  If the error
  201.      still occurs you may need to de-select the enable Share Option
  202.      in Network under Control Panel.
  203.  
  204. 5.0  General Trouble-Shooting Hints.
  205.      SOFTWARE.  If you are not able to resolve an error after
  206.      following the suggestions given on the error screen, it is
  207.      recommended to do the following:
  208.   1.  Re-try the operation, look for consistent results.  
  209.   2.  Try another tape.  Make sure your tapes are on the
  210.           Approved Tapes List in the manual or use a Colorado
  211.           Memory Systems brand tape for your drive. 
  212.  3.  Check the hard drive for lost clusters, bad sectors, and
  213.           fragmentation.  If errors occur, correct by running a disk 
  214.           utility (Norton Utilities, PCTools, etc.) or use 'CHKDSK /F'.  
  215.        See your Dos manual for more information.
  216.  4.  Close down all other applications, remove items from your
  217.           startup group and remark items out of the load= and run=
  218.           lines in the WIN.INI file.
  219.  5.  Re-boot with a clean AUTOEXEC.BAT and CONFIG.SYS.  It is
  220.       recommended that this be done from a bootable floppy
  221.       diskette.  To receive a fax with instructions for this
  222.       process, dial our fax-back service at 1-800-368-9673 and
  223.       request document #2900.
  224.  
  225. HARDWARE.  If the drive does not respond when you try to access it
  226. with the software, do the following:  
  227. 1.  Remove the tape from the drive and examine it.  If the tape is
  228.      unspooled, refer to the drive cleaning instructions in the
  229.      manual or refer to QICFAX document  #2020.
  230. 2.  Close down all programs, exit Windows and turn the power off                                             
  231.      on the computer.  If your tape drive plugs directly into the wall
  232.      outlet, disconnect it from the wall outlet, wait a few seconds
  233.      and then re-connect it. Turn the power back on.  
  234. 3.  Place a tape in the drive and look to see if the LED is
  235.      functioning normally.  The tape drive LED should not be on
  236.      after the tape stops spinning.
  237.  
  238. ERRORS and SOME REMEDIES
  239. (If at anytime changes are made to the Windows System.ini or the Win.ini
  240. files, please save the changes and then exit Windows thru Program Manager, 
  241. file and exit. Then type win at the DOS prompt to restart Windows. 
  242. When changes are made to the Autoexec.bat or Config.sys,
  243. if in Windows, please exit  Windows thru Program Manager, file and exit; 
  244. and at the DOS prompt  reboot your computer.)
  245.  
  246. 10E  Unexpected or Bad List Item
  247. -  Low actual memory/Resources (Free up memory by closing other Windows applications.  Also check to see if you can identify any TSR programs that you might be loading in your CONFIG.SYS or AUTOEXEC.BAT files that are not necessary for your system to operate.  i.e.  Screen Blanker, Anti-Virus, etc.)
  248. -  Try adding /Double_Buffers + to SMARTDRV.EXE in the CONFIG.SYS file.
  249. -  Try adding the line "DEVICE=C:\path\EMM386.EXE RAM M9" to the CONFIG.SYS file.  If you already have an EMM386.EXE line, REMARK the line and add this one.  Please make a bootable floppy and make sure that you can boot from your A: drive prior to changing this.  This changes the way memory is accessed and in some cases may conflict with something, preventing you from booting.
  250. -  Disable write caching (this applies to all disk caching utilities)
  251. -  If backing up a network drive, you may want to check your local drive to see if it is being accessed.  If it is, it may be wise to upgrade the memory in the computer to help prevent Windows from using the swap file in such a manner.
  252. -  If you are using CBW 1.01, please check with Windows Customer Support to see if an upgrade will help your problem
  253.         
  254. 61B  Interrupt Not Available
  255. -  If another Colorado Backup Error has preceded this error, make sure that you exit Windows and restart the computer before trying to run CBW.
  256. -  Possible driver conflict, check for Fastback.386, VIRWT.386, VFINTD.386, CPBVXD.386, VITD.386 in your SYSTEM.INI file.
  257. -  Possible memory conflict.  Try to REMARK out your EMM386.EXE line in your CONFIG.SYS file.  If this fixes the problem, you may want to try a different configuration of EMM386.
  258. -  Try adding IRQ9GLOBAL=YES to the [386ENH] section of your SYSTEM.INI file.
  259.  
  260. 73D  User Manager Timeout
  261. -  Could be a bad tape.     Try other tapes to see if this error is consistent with all tapes.
  262. -  Lost clusters or bad sectors on the hard disk drive may cause this type of error.  Please run a hard disk utility or CHKDSK from DOS to check for hard disk corruption.  
  263. -  Try adding IRQ9GLOBAL=YES to the [386ENH] section of your SYSTEM.INI.
  264.         
  265. 209  Memory Bad Request
  266. -  If you are using DR DOS 6.0 - delete INSTALL.TMP and CBW.DRV from the CBW directory or the directory you installed the tape backup software into.  Run CBW and configure the software for a tape drive.  Hint - Select Option, Tape Drive Configuration, and Configure New Tape Drive. 
  267. -  Lost clusters or bad sectors on the hard disk drive may cause this type of error.  Please run a hard disk utility or CHKDSK from DOS to check for hard disk corruption.  
  268. -  Possible bad tape.   Try other tapes to see if this error is consistent with all tapes.
  269. -  If you are attached to a dedicated controller, such as and FC-10 or TC-15, try alternative settings for the controller. 
  270. -  Your system may have settings for External Cache and Internal Cache.  Set these to disabled and see if that affects the operation of CBW.    
  271.         
  272. 514  Tape header contains unexpected or invalid values
  273. -  The tape may be unformatted or incorrectly formatted.  Please try another tape or try to format the current tape.  Sometimes just retensioning a tape can help.
  274. -  If you are attached to a dedicated controller, such as and FC-10 or TC-15, try alternative settings for the controller. 
  275.  
  276. 733  Unable to establish communication with the task manager
  277. -  Check for DEVICE=CMSWTAPE.386 in the [386ENH] section of the SYSTEM.INI file.  If this is not present, add this line as the first line under [386ENH].
  278. -  Try to reinstall software.
  279.  
  280. 1165/1167  Drive Communication Fault
  281. -  If loading SMARTDRV.EXE in the CONFIG.SYS and AUTOEXEC.BAT files, try to REMARK SMARTDRV.EXE out of the AUTOEXEC.BAT
  282. -  Remove the tape drive from the configuration and re-configure the software for a new tape drive.  Hint - Select Option, Tape Drive Configuration, Remove Tape Drive Configuration and then Select Option, Tape Drive Configuration, Configure New Tape Drive. 
  283. -  Check all hardware connections.
  284. -  In the Virtual Memory settings of 386 Enhanced, which can be found in the Control Panel folder, of the main group, there is an option for 32-bit disk access.  If it is enabled, disable it.  If it is disabled, enable it.  If it has no effect, return it to the original setting.
  285. -  Try to reinstall software.
  286.  
  287. 1176 Drive Configuration Fault
  288. -  CBW looks for drive specific information.  If you are using a drive other than that which was used when CBW was configured, you should do the following.  Remove the tape drive from the configuration and re-configure the software for a new tape drive.  Hint - Select Option, Tape Drive Configuration, Remove Tape Drive Configuration and then Select Option, Tape Drive Configuration, Configure New Tape Drive. 
  289. -  Try to reinstall software.
  290.  
  291. F02  Tape drive controller configuration failed
  292. -  Reboot system then run windows and CBW software again.
  293. -  Make sure dedicated controller board(TC-15 or FC-10) is seated in the expansion slot.
  294. -  Manually re configure the controller board.
  295.     
  296. F1B  Trakker: Parallel Port Interrupt Not Available Or In Use
  297. -  Sound card or Scanner is set to same interrupt as parallel port.  It may be necessary to change the interrupt of either the parallel port or the conflicting controller.
  298. -  If the Trakker and Printer are attached to the same parallel port, they can NOT be used at the same time.
  299. -  This error can be caused if the DOS command SUBST has been used.
  300.  
  301. Attempting Tape Error Recovery
  302. -  This may be caused by a bad block on the tape.  Try another tape, if this works, try to reformat the tape that causes the problem.
  303. -  If the tape drive head is dirty, this may cause problems reading.  Clean the tape drive head and try operation again.
  304. -  Low actual memory/Resources (Free up memory by closing other Windows applications.  Also check to see if you can identify any TSR programs that you might be loading in your CONFIG.SYS or AUTOEXEC.BAT files that are not necessary for your system to operate.  i.e.  Screen Blanker, Anti-Virus, etc.)
  305. -  The tape software may be corrupt.  Try to reinstall CBW. 
  306. -  If you are attached to a dedicated controller, such as and FC-10 or TC-15, try alternative settings for the controller.  Avoid using DMA channel 2.
  307. -  Lost clusters or bad sectors on the hard disk drive may cause this type of error.  Please run a hard disk utility or CHKDSK from DOS to check for hard disk corruption.  
  308. -  In the Virtual Memory settings of 386 Enhanced, which can be found in the Control Panel folder, of the main folder, there is an option for 32-bit disk access.  If it is enabled, disable it.  If it is disabled, enable it.  If it has no effect, return it to the original setting.
  309.  
  310. General Protection Fault
  311. -  This may be caused by a bad block on the tape.  Try another tape, if this works, try to reformat the tape that causes the problem.
  312. -  Lost clusters or bad sectors on the hard disk drive may cause this type of error.  Please run a hard disk utility or CHKDSK from DOS to check for hard disk corruption.  
  313. -  Possible driver conflict, check for Fastback.386, VIRWT.386, VFINTD.386, CPBVXD.386, VITD.386 in your SYSTEM.INI file.
  314. -  Possible memory conflict.  REMARK out your EMM386.EXE line in your CONFIG.SYS file.  If this fixes the problem, you may want to try a different configuration of EMM386.
  315. -  Possible conflict with IMouse.  Check the AUTOEXEC.BAT and CONFIG.SYS files.  If this program is present, REMARK the driver and try again.
  316. -  If you are attached to a dedicated controller, such as and FC-10 or TC-15, try alternative settings for the controller.  Avoid using DMA channel 2.
  317. -  Check for DEVICE=CMSWTAPE.386 in the [386ENH] section of the SYSTEM.INI file. If this is not present, add this line as the first line under [386ENH].
  318.         
  319. Trakker configuration issues
  320. -  Sound card or Scanner is set to same interrupt as parallel port.  It may be necessary to change the interrupt of either the parallel port or the conflicting controller.
  321. -  Disable "Windows Printing System"
  322. -  Disable "Super Queue"
  323. -  May be caused if FAX modem is selected as printer.  Change printer from fax to a printer.