home *** CD-ROM | disk | FTP | other *** search
/ ftp.tcs3.com / ftp.tcs3.com.tar / ftp.tcs3.com / DRIVERS / Video / TSeng / ET4000PC.ZIP / ACAD.ZIP / TRBDLD.TXT < prev    next >
Text File  |  1994-06-07  |  89KB  |  1,979 lines

  1.  
  2.  
  3. TurboDLD
  4. Classic
  5.  
  6.  
  7.  
  8. Version 2.0
  9.  
  10.  
  11. for AutoCADr Release 12, 11/386, and 10/386,
  12. AutoShade 2 with RenderMan, and 3D Studio
  13.  
  14.  
  15.  
  16.  
  17. Features:
  18. ∙    Includes a bird's eye view and a graphics-mode text window.
  19. ∙    Accelerates redraws, pans, and zooms.
  20. ∙    Easy to use - no new commands or special menus to learn.
  21. ∙    Protected-mode ADI 4.2 driver -- completely compatible with AutoCAD 
  22.                Release 12, Release 11/386, Release 10/386, 3D Studio and AutoShade 2
  23.                with RenderMan.
  24. ∙    No memory conflicts. Works with AutoCAD's built-in Virtual Memory 
  25.                Manager.
  26. ∙    Includes CustomColorsÖ, which lets you interactively customize your logical 
  27.                and physical colors from within AutoCAD.
  28. ∙    Completely compatible with all AutoCAD ADI 4.2 compatible third party 
  29.                software.
  30. ∙    Will support higher resolutions on all popular graphics boards.
  31. ∙    Supports all AutoCAD Release 12 features, including rendering to viewports 
  32.                and 31-Bit regen space.
  33.  
  34. System 
  35. Requirements:
  36. ∙    A '386, '486 or Pentium based PC which supports AutoCAD Release 12, 
  37.               11/386, 10/386, AutoShade 2 with RenderMan, or 3D Studio v1, v2 or v3.
  38. ∙    A compatible graphics board. TurboDLDClassic will work with all popular 
  39.               graphics boards.
  40. ∙    Additional extended memory is recommended for optimal performance.
  41.  
  42.  
  43.  
  44. Installation Guide
  45.  
  46.  
  47. TurboDLDClassic
  48.  
  49.  
  50. A note on copying this software:
  51.  
  52. Each copy of TurboDLDClassic is encoded with a unique serial number. This serial number is used as a 
  53. check to ensure that the software is not being illegally duplicated. If an illegal copy of the software is 
  54. found, the serial number provides us with a means of tracking down the source of the duplications. If you 
  55. need to use multiple copies at the same time, contact your dealer for information on purchasing additional 
  56. pieces of this software. Site licensing terms are available for multiple unit purchases. Educational pricing 
  57. for qualified institutions is also available.
  58.  
  59. Help us keep you up-to-date with the latest and greatest version.  Fill out and return the registration card 
  60. today.  Remember, registered users get free technical support and 30 (thirty) days of free updates.
  61.  
  62. Information in this document is subject to change without notice and does not represent a commitment on 
  63. the manufacturer.  (Late additions to this document may be found in the READ.ME file on the distribution 
  64. disk.)  The software described in this document is furnished under a license agreement or nondisclosure 
  65. agreement.  The software may be used or copied only in accordance with the terms of the agreement.  It is 
  66. against the law to copy TurboDLDClassic on magnetic tape, disk, or any other medium for any purpose 
  67. other than the purchaser's personal use, as defined in the license agreement.
  68.  
  69.  
  70. Copyright (c) 1989-1994   All rights reserved.
  71.  
  72. Portions of TurboDLDClassic are patented under U.S. Patent No. 5,101,444.
  73.  
  74. Panacea and DLD are registered trademarks and,  TurboDLD, TurboDLDClassic, TurboDLDDeluxe, DLD386,  DLD386Deluxe, Display List Driver, CustomColors, Panacea, ZoomPreview, "The Designated Drivers",  
  75. The Big Picture,  TOTS, MicroScope, MACH-12 and CAD Accelerators are trademarks of Panacea Inc.
  76.  
  77. AutoCAD and Autodesk are registered trademarks, and AutoShade, AutoSketch and 3D Studio, are trademarks 
  78. of Autodesk, Inc. RenderMan is a trademark of Pixar. All other brand and product names are trademarks of their 
  79. respective owners. 
  80.  
  81. Some TurboDLDClassic fonts are supplied by IBM and Tseng Labs.
  82.  
  83.  
  84.  
  85.  
  86.  
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.  
  94.  
  95.  
  96.  
  97.  
  98. Table of Contents
  99. About This Manual    ...            i-i
  100. Quick Start                        1-1
  101. Panacea TurboDLDClassic            2-1
  102. Installing and Configuring TurboDLDClassic    3-1
  103. Changing Colors                    4-1
  104. TurboDLD Features                5-1
  105. Memory Usage and Lists                6-1
  106. Tips, Tricks and Troubleshooting             7-1
  107. Rendering With TurboDLDClassic            8-1
  108. Appendix A - Support Information            A-1
  109. Appendix B - TurboDLDClassic Commands        B-1
  110. Appendix C - Changes From Previous Versions    C-1
  111.  
  112.  
  113.  
  114.  
  115.  
  116. About
  117. This 
  118. Manual
  119.  
  120. Thank you for purchasing TurboDLDClassic  v2.0 -- and also for reading this 
  121. manual. We are very excited about this release of TurboDLD, mainly because of 
  122. you, the AutoCAD user. Many of the features and enhancements of this version 
  123. are the result of your comments and requests. With that input, we are able to offer 
  124. you a complete productivity solution at an affordable price.
  125.  
  126. This introduction provides a quick overview of the terms and conventions used 
  127. throughout the manual. Please take a few minutes to familiarize yourself with it.
  128.  
  129. AutoCAD Installations
  130. We know that every AutoCAD installation is different. However each one requires 
  131. the configuration of the same basic parameters in order to function. The examples 
  132. we use in this manual assume that you have installed AutoCAD on drive C using 
  133. the installation defaults. This means that your main AutoCAD directory is 
  134. C:\ACAD and all other directories (i.e., SUPPORT, FONTS, DRV, etc.) fall under 
  135. it.
  136.  
  137. We also assume that you are using the AutoCAD created ACADR12.BAT file to 
  138. start AutoCAD Release 12. For AutoCAD Releases 10/386 and 11, it is not as 
  139. critical to use a batch file to start the program, however it is much easier.
  140.  
  141. If you have not configured AutoCAD using defaults, don't worry, you can still 
  142. easily install TurboDLDClassic. All you have to do is substitute your specific sub-
  143. directory names with those in our examples.  If you are using a menuing system or 
  144. other AutoCAD start-up file, use that when we reference ACADR12.BAT.
  145.  TurboDLD Installation
  146. Our references to the location of TurboDLD files assume that you have chosen to 
  147. install TurboDLDClassic into the C:\ACAD\DRV sub-directory for AutoCAD 
  148. Release 12, or in a sub-directory named C:\TURBODLD for AutoCAD Release 10 
  149. or 11. 
  150.  
  151. Naming Conventions
  152. To save some space (not to mention a tree or two) and to make the manual a little 
  153. easier to read, we have abbreviated some name references.  If you see the terms 
  154. below used later in these pages, here's what they mean.
  155.  
  156. BP = Big Picture, TurboDLD's bird's eye view
  157. R12 = AutoCAD Release 12
  158. R11 = AutoCAD Release 11
  159. R10 = AutoCAD Release 10/386
  160.  
  161.  
  162. Keyboard References
  163. CTRL-C = Hold the CTRL key down and then press the "C" key.
  164.  
  165. ESC = The ESCape key in the upper left-hand corner of your keyboard. 
  166.  
  167. ARROW key references are to the cursor control keys on your keyboard, the four 
  168. keys in-between the main keys and the numeric keypad. 
  169.  
  170. Keyboard Input
  171. Bold text throughout the manual indicates an important point, or prompt. In the 
  172. case of a prompt, input is required, either at the DOS prompt or the AutoCAD 
  173. Command prompt.
  174.  
  175. Notes, Tips & Cautions
  176. Throughout the manual, there are specific points you should be aware of,or should 
  177. avoid. These bits of information are separated from the main body of the manual 
  178. and are identified with the following icons.
  179.  
  180.                                     
  181.  
  182.  
  183.  
  184.  
  185.  
  186.  
  187.  
  188.  
  189.  
  190.  
  191. Chapter 1
  192.  
  193. Quick
  194. Start
  195. These pages sum up the basics of installing and using TurboDLDClassic. Please 
  196. read the rest of the manual for complete details.  
  197.  
  198. What's it do?      TurboDLDClassic 's main function is to speed up AutoCAD pans, zooms and 
  199. redraws. The driver accomplishes this by creating and maintaining a Display List - 
  200. a fast-displaying object list of the current drawing - dramatically increasing 
  201. performance on pans and zooms.
  202.  
  203. In addition to offering display list speed enhancement, TurboDLDClassic provides 
  204. add-on productivity features -  a bird's-eye view and a graphics mode text window 
  205. - to further speed up the use of AutoCAD.
  206.  
  207.  
  208. What's the Catch?      The only resource used by TurboDLDClassic  is memory. The driver 
  209. actively uses about 300Kbytes of RAM from extended memory for its operation. This memory 
  210. is drawn from AutoCAD's memory pool and therefore does not affect normal DOS operation. 
  211. The driver is loaded by AutoCAD at AutoCAD load time and is unloaded when AutoCAD is exited.
  212.  
  213. Additionally, the Display List size can vary from one tenth to three times the size 
  214. of the current drawing file. We recommend that you use 8Mb of RAM with 
  215. AutoCAD Release 10/386 or 11, and 12Mb for AutoCAD Release 12.
  216.  
  217. You may wish to purchase and install additional RAM before installing 
  218. TurboDLDClassic, since it shares memory with AutoCAD. If AutoCAD is using a 
  219. lot of memory, TurboDLDClassic may not have enough.  If there is significant 
  220. hard disk activity while you are using TurboDLDClassic, it may be an indication 
  221. that you should add more memory to your system.
  222.  
  223. Install                  Run the TurboDLDClassic installation program by typing:
  224.  
  225.     A: (or B: if you are using drive B)
  226.     INSTALL
  227.  
  228. TurboDLDClassic's install program will ask for registration information and then 
  229. prompt for AutoCAD information. The remaining prompts will ask for sub-
  230. directory information. After all information has been provided,  TurboDLDClassic 
  231. files will be copied from the distribution floppy to the hard drive.
  232.  
  233.  
  234.  
  235. To Configure
  236. AutoCAD 
  237. Release 12
  238.  
  239. Since the start-up is a little bit different for AutoCAD Release 12 than for older 
  240. versions, please follow the instructions for the version of AutoCAD which you are 
  241. installing TurboDLDClassic for.
  242.  
  243. Begin AutoCAD with the reconfigure switch by typing
  244.  
  245.     ACAD -R
  246.  
  247. Choose option 3, Configure Video Display from the AutoCAD configuration 
  248. menu.
  249.  
  250. Type Y at the "Do you want to select..." message to display the available video 
  251. options for AutoCAD.
  252.  
  253. Select "TurboDLD Classic" from the list of display options.
  254.  
  255. Alternately, to get to the AutoCAD Configuration menu described above, start 
  256. AutoCAD as you normally would, and then type CONFIG at the Command 
  257. prompt.
  258.  
  259. Continue installation at the Driver Configuration section below.
  260.  
  261. Run the FASTACAD batch file created in your TurboDLDClassic sub-directory 
  262. and then start AutoCAD.
  263.  
  264.  
  265. To Configure
  266. AutoCAD
  267. Release 11/386,
  268. Release 10/386
  269.  
  270. Reconfigure AutoCAD to use TurboDLDClassic by selecting option 5, Configure 
  271. AutoCAD from the AutoCAD main menu. From the next menu, select option 3, 
  272. Configure Video Display.  Choose Item 1, P386 ADI 4.0/4.1 (R11) or ADI P386 
  273. (R10), as your display device. (For more information, see your AutoCAD 
  274. "Installation and Performance Guide.")
  275.  
  276. After selecting the proper display device, the TurboDLD Driver Configuration 
  277. menu will appear.
  278.  
  279.  
  280.  
  281. Driver
  282. Configuration
  283.  
  284. Set-up of TurboDLDClassic requires configuration of its various operating 
  285. parameters. These parameters have been logically grouped into menus based on 
  286. their interaction with AutoCAD. A quick trip through each menu will complete the 
  287. configuration process. Context sensitive help can be obtained by typing "?" at any 
  288. menu option.
  289.  
  290. The first menu, Select Graphics Board/Resolution, configures TurboDLDClassic 
  291. for the graphics board, and display and rendering resolutions to be used.
  292.  
  293. ∙     Select Graphics Board Selects graphics platform to be used
  294. ∙     Select Display Resolution Selects AutoCAD, 3D Studio and AutoShade main 
  295.                display screen resolutions
  296. ∙     Select Rendering Resolution Selects AVE Render, 3D Studio and AutoShade 
  297.                rendering resolutions
  298.  
  299. Rendering menu options only appear when configuring the rendering screens of 
  300. AVE Render, 3D Studio and AutoShade2 with RenderMan.  You will not see both 
  301. menu options at the same time.
  302.  
  303. Basic Configuration options set AutoCAD screen characteristics, number of text 
  304. lines in the command-line area, font size and screen configuration mode.
  305.  
  306. ∙    AutoCAD Text Lines Selects number of lines in AutoCAD command prompt 
  307.     area
  308. ∙    Screen Configuration Provides a choice of single screen, dual screen or single 
  309.     screen with a graphics mode text window.
  310. ∙     Font Selection Allows selection of TurboDLDClassic  supplied fonts or 
  311.     Autodesk supplied .BDF fonts menus and pull-downs. 
  312.  
  313. User Interface options include the parameters for maneuvering within AutoCAD.
  314. ∙    Double Click Sets mouse/digitizer double click detect time.
  315. ∙    BP Button Select which mouse or tablet button to use for bird's eye pop-up.
  316. ∙    BP Highlight Mode Controls how the Big Picture is displayed.
  317. ∙     BP Refresh Controls the refresh mode of the Big Picture. 
  318.  
  319. Expert Configuration options set the function of TurboDLD itself. This menu 
  320. allows for customization of the driver for speed or to adjust for memory 
  321. constraints.
  322.  
  323. ∙    Display List Enables or disables the display list feature of TurboDLDClassic.
  324. ∙    AutoCAD Logical Drawing Space Sets AutoCAD's logical space to 15-bits
  325.     or 31-bits (R12 only).
  326. ∙    Internal Command Echo Enables or disables the echo of TurboDLDClassic 
  327.     internal commands at the AutoCAD Command line when such commands are 
  328.     executed.
  329. ∙    Big Picture Zoom Mode Sets Big Picture zoom area display options
  330.  
  331. Once all options have been set, scroll down to the Save and Exit option and then 
  332. press the ENTER key to continue.
  333.  
  334. Next, configure the AutoCAD screen display characteristics and then type Y to 
  335. accept the changes.
  336.  
  337. Exit to the AutoCAD drawing editor to begin using TurboDLDClassic.
  338.  
  339. The last step in setting-up TurboDLDClassic is to configure the colors for 
  340. AutoCAD. From the AutoCAD Command Line, type DLDCOLOR, to start 
  341. CustomColors, TurboDLD's color configuration utility. Make any desired color 
  342. changes and then Save the new color palette and then Exit to return to the drawing 
  343. editor.
  344.  
  345. If you encounter a problem or abnormality, please review the installation procedure and 
  346. Chapter 7 - Tips, Tricks & Troubleshooting. to be sure you haven't overlooked or skipped 
  347. a step. If  you still cannot resolve the problem, refer to  Appendix A to obtain Technical Support.
  348.  
  349.  
  350.  
  351. Chapter 2
  352.  
  353. TurboDLD
  354. Classic 
  355.  
  356. TurboDLD Classic has only two purposes: 1) to speed up AutoCAD REDRAWs, 
  357. PANs, and ZOOMs; and 2) to provide a more productive, user-friendly, interface 
  358. to AutoCAD (via the features described in Chapter 5 - TurboDLD Features).
  359.  
  360. The driver is memory-resident and inserts itself between AutoCAD and the 
  361. graphics board.  It has no other effect on AutoCAD's operation besides speeding 
  362. the program up; it runs with AutoShade 2 with RenderMan and all versions of 3D 
  363. Studio, but does not affect the speed of these programs, since they do not support 
  364. Display Lists. 
  365.  
  366. Installing TurboDLDClassic does not change any of the AutoCAD program files 
  367. or alter any of the drawing files stored on disk.  TurboDLDClassic was designed 
  368. to be an easy-to-use, feature-filled product that makes using AutoCAD faster and 
  369. more productive, not one that makes AutoCAD more complicated and difficult to 
  370. use.  
  371.  
  372. How does TurboDLDClassic make AutoCAD run faster?  There are mainly two 
  373. things the driver does to speed operation:
  374.  
  375. ∙    AutoCAD stores drawings in a  hierarchical structure, with simple elements 
  376.     intermixed with complex ones.  Every time the screen is updated, AutoCAD 
  377.     must decode this structure.  TurboDLDClassic works differently.  While you 
  378.     are working, it translates the normal hierarchical structure into a Display List, a 
  379.     series of vectors or polygon fills.  (The ability to support display lists was 
  380.     specifically added to AutoCAD with Release 10 via the ADI 4.0 interface.)  
  381.     When you pan or zoom, TurboDLDClassic uses the Display List, then writes 
  382.     the resulting vectors to the video board hardware.  Since the hierarchical 
  383.     structure does not have to be decoded, drawing proceeds very quickly.  
  384.  
  385. ∙    Lastly, TurboDLDClassic gives you new user-interface features, including a 
  386.     bird's eye view and a graphics-mode text window. (See Chapter 5 - TurboDLD 
  387.     Features .)
  388.  
  389. By how much does TurboDLDClassic increase the speed of AutoCAD?  PANs and ZOOMs, 
  390. aided by only the Display List, run from two to twelve times faster than a non-display list driver.  
  391. TurboDLDClassic's internal display list processing can speed things up to the point that REDRAWs 
  392. can be up to twenty-five times faster than the graphics drivers shipped with AutoCAD.
  393.  
  394.  
  395.  
  396. Chapter 3
  397.  
  398. Installing 
  399. and 
  400. Configuring
  401. TurboDLD
  402. Classic
  403.  
  404. Before starting, please make a backup copy of the distribution disk, using the 
  405. DOS DISKCOPY command, and put it in a safe place. Also, if you have been 
  406. using an older version of a Panacea driver - DLD-VGA, DLD386-VGA, MACH-
  407. 12... - be sure to remove any references to that driver which may be in your 
  408. AutoCAD start-up files or in your AUTOEXEC.BAT file.  
  409.  
  410. The TurboDLDClassic installation procedure below is exact, and describes what 
  411. to do at each step.
  412.  
  413. Installation is slightly different for older releases of AutoCAD than it is with 
  414. AutoCAD Release 12. Be sure to follow any directions that may be specific to 
  415. your particular AutoCAD release. For brief installation instructions, see the Quick 
  416. Start section at the front of the manual.
  417. Installation
  418. Insert your TurboDLDClassic distribution disk into a floppy disk drive and then 
  419. type:
  420.  
  421. {Drive}:INSTALL
  422.  
  423. Where {Drive} is the floppy drive that holds the TurboDLDClassic disk.
  424.  
  425. The first time the installation program is run, you will be prompted for registration 
  426. information. This information must be given. If you choose to ignore this step, 
  427. TurboDLDClassic will not run.
  428.  
  429. After completing the registration information, TurboDLDClassic's installation will 
  430. prompt you for the version of AutoCAD you are installing the driver for.
  431.  
  432. Next, you will be asked for the the name of the directory you wish to install 
  433. TurboDLDClassic into. In the space provided, enter a complete sub-directory path 
  434. name.
  435.  
  436. Once the path name has been entered, verify that the information is correct and 
  437. then press ENTER. The TurboDLDClassic files are then copied from the 
  438. distribution floppy to your hard drive.
  439.  
  440. Once all of the program files have been successfully transferred, it is necessary to 
  441. reconfigure AutoCAD to use TurboDLDClassic. Follow the steps below for use 
  442. with either AutoCAD Release 12, or Release 10/11, and then proceed to the Driver 
  443. Configuration section below, to complete the installation.
  444.  
  445. For Use With AutoCAD Release 12
  446.  
  447. Begin AutoCAD with the reconfigure switch by typing
  448.  
  449.     ACAD -R
  450.  
  451. Choose option 3, Configure Video Display from the AutoCAD configuration 
  452. menu. (See Figure 3.1.)
  453.  
  454.  
  455. Figure 3.1 - AutoCAD Release 12 Configuration Menu
  456.  
  457. Type Y at the "Do you want to select..." message to display the available video 
  458. options for AutoCAD.
  459.  
  460. Select "TurboDLD Classic by Panacea Inc - v2.0" from the list of display 
  461. options.
  462.  
  463. Alternately, to get to the AutoCAD Configuration menu described above, start 
  464. AutoCAD as you normally would, and then type CONFIG at the Command 
  465. prompt.
  466.  
  467. TurboDLDClassic  usually appears as option 11 in most installations of AutoCAD 
  468. Release 12. If TurboDLD does not appear in the list of available video drivers, be 
  469. sure that the AutoCAD environment variables in your AutoCAD start-up file, 
  470. ACADDRV in particular, have been properly set before typing ACAD -R.
  471.  
  472. Continue to the "Driver Configuration" section below.
  473. For Use With AutoCAD Release 10/386 or 11/386
  474. Run the FASTACAD.BAT file that was  copied to the TurboDLDClassic sub-
  475. directory by typing:
  476.  
  477.     C:\TURBODLD\FASTACAD
  478.  
  479. The above example assumes that TurboDLDClassic was installed on drive C: in a 
  480. sub-directory named TURBODLD. FASTACAD sets up the necessary AutoCAD 
  481. environment variables for use with TurboDLDClassic. For more information on 
  482. FASTACAD.BAT, refer to the Configuring the AutoCAD Operating Environment 
  483. section at the end of this chapter.
  484.  
  485. Start AutoCAD and reconfigure the program to use TurboDLDClassic by 
  486. selecting option 5, Configure AutoCAD from the AutoCAD main menu. From 
  487. the next menu, select option 3, Configure Video Display.  Choose Item 1, P386 
  488. ADI 4.0/4.1 (R11) or ADI P386 (R10) as your display device. (for more 
  489. information about configuring for ADI drivers, see the AutoCAD "Installation 
  490. and Performance Guide".
  491.  
  492. Driver Configuration
  493.  
  494. Once you have selected the proper display device, the TurboDLD Welcome screen 
  495. will appear. This screen is an informational screen about what the 
  496. TurboDLDClassic setup program does. Press any key to continue once you have 
  497. read the overview.
  498.  
  499.  
  500. Figure 3.2  - TurboDLDClassic Configuration Menu
  501.  
  502. As you continue past the Welcome screen, the TurboDLDClassic Driver 
  503. Configuration menu will appear. (See Figure 3.2.)
  504.  
  505. Help during TurboDLDClassic setup is only a keystroke away. At any time, you 
  506. may press the question mark ("?") key to get help information pertaining to the 
  507. current prompt. Please note that the DLDSETUP.HLP file must be present in 
  508. order for help to appear. If you get an error message, be sure that the file 
  509. DLDSETUP.HLP is in the ACAD\DRV sub-directory (R12), or in the 
  510. TURBODLD sub-directory (R10/R11). Also, as mentioned earlier, be sure that 
  511. there are no references to older DLD drivers which may cause TurboDLDClassic 
  512. to look elsewhere for DLDSETUP.HLP.
  513.  
  514.  
  515. Figure 3.3 - Graphics Board Selection Menu
  516.  
  517. If at any point during the configuration process you want to change an item on a 
  518. previous screen, just press the ESC key to back up. Selecting NO SAVE, EXIT at 
  519. the main configuration menu will return you to the AutoCAD configuration menu 
  520. without making any changes.
  521.  
  522. Set-up of TurboDLDClassic requires configuration of the various operating 
  523. parameters of the driver. These parameters have been logically grouped into five 
  524. menus based on their interaction with AutoCAD. A quick trip through each menu 
  525. will complete the configuration process.
  526.  
  527. If none of TurboDLDClassic's options are configured, the driver will be 
  528. automatically configured as a Generic VGA, with 640 x 480 resolution at 16 
  529. colors. All other driver options will assume the program's defaults.
  530.  
  531. Select Graphics Board/Resolution Menu
  532.  
  533. The Select Graphics Board/Resolution menu configures TurboDLDClassic for 
  534. video parameters. From this menu, graphics board/type and display and rendering 
  535. resolutions for TurboDLDClassic will be determined.
  536.  
  537. Select Graphics Board (See Figure 3.4) allows you to manually select your 
  538. computer's graphics board. A list of video cards is given, based on the the findings 
  539. of TurboDLDClassic's built-in graphics platform detection utility. Use the Up and 
  540. Down arrow keys, and the Pg Up and Pg Dn keys to scroll through the list and 
  541. highlight your graphics board. Please note that graphics boards are listed by both 
  542. platform type and manufacturer's name, alphabetically, therefore you may need to 
  543. scroll to the bottom of the list to find your particular board.
  544.  
  545.  
  546.  
  547.  
  548. Figure 3.4 - Graphics Board Menu
  549.  
  550. If your graphics board is not listed, you may choose the generic board option for 
  551. your video chip type.
  552.  
  553. Press ENTER to accept your choice and return to the Select Graphics 
  554. Board/Resolution menu.
  555.  
  556. Select Display Resolution configures the resolution of the AutoCAD drawing 
  557. screen. Display screen options are based on the findings of TurboDLDClassic's 
  558. graphics platform detection utility (see Figure 3.5). Use the Up and Down arrow 
  559. keys, and the Pg Up and Pg Dn keys to scroll through and highlight the resolution 
  560. and color option you wish to use. Press the ENTER key to accept your resolution 
  561. choice and return to the Select Graphics Board/Resolution menu.
  562.  
  563. When configuring TurboDLDClassic's video options, the Rendering 
  564. Board/Resolution options described below will automatically appear ONLY when 
  565. configuring the rendering modes of AVE Render, 3D Studio or AutoShade 2 with 
  566. RenderMan. Otherwise, the Display Board/Resolution options will be the only 
  567. menu choices available.  
  568.  
  569.  
  570.  
  571.  
  572.  
  573. Figure 3.5 - Resolution Selection Menu
  574.  
  575. Similar to the Select Display Resolution menu, Select Rendering Resolution 
  576. configures the resolution of the AutoCAD rendering screen. Rendering screen 
  577. options are also based on the findings of TurboDLDClassic's detection utility. Use 
  578. the Up and Down arrow keys, and the Pg Up and Pg Dn keys to scroll through 
  579. and highlight the resolution and color option you wish to use.
  580.  
  581. Press ENTER to accept your choice and return to the Select Graphics 
  582. Board/Resolution menu.
  583.  
  584. TurboDLDClassic's graphics platform detection utility queries the graphics card 
  585. for graphics platform type and installed memory. Based on the detector's 
  586. information, TurboDLDClassic will list a set of Display and Rendering 
  587. resolutions. Due to the variety of graphics boards and their specific 
  588. implementations of platform chip sets, the detector is general purpose and cannot 
  589. always be 100% accurate. Therefore, when selecting a Display or Rendering 
  590. resolution, be sure to use only resolutions that you know your graphics board, and 
  591. monitor, will support. If you are unsure which resolutions are supported by your 
  592. graphics board and monitor, refer to your owner's manual(s).
  593.  
  594. Highlight Return To Previous Menu and press the RETURN key to return to the 
  595. Main Configuration Menu.
  596.  
  597.  
  598. Basic Configuration Menu
  599.  
  600. The Basic Configuration menu configures TurboDLDClassic's AutoCAD screen 
  601. characteristics; text lines; screen mode; and font size (see Figure 3.6).
  602.  
  603. The first Basic option is the number of text lines you wish to use for the AutoCAD 
  604. command line. The default is 3 lines, but values from 1 to 10 can be specified. A 
  605. number larger than 3 might be useful if you are using this driver in a high 
  606. resolution mode with small fonts, eliminating the need to frequently swap back 
  607. and forth between the text and graphics screens.
  608.  
  609. If you do not want any lines of text at the bottom of the display, use AutoCAD to 
  610. disable the command area (see the AutoCAD "Interface, Installation and 
  611. Performance Guide" for more information).
  612.  
  613. The Screen Configuration section is used to tell TurboDLDClassic under which 
  614. of three available modes you wish to use AutoCAD -- dual screen, one monitor for 
  615. graphics and a second for text; single screen with combined text and graphics; or 
  616. single screen with combined text and graphics using a graphics mode text window.
  617.  
  618.  
  619. Figure 3.6 -Basic Configuration  Menu
  620.  
  621. Use the arrow keys to highlight a choice based on the following explanations of 
  622. each mode. Select Dual to run in dual screen mode.
  623.  
  624. Do not select Dual if you don't have a second video board in your system, 
  625. unpredictable results will occur. To use dual screens, you must have a 
  626. Monochrome board installed with a VGA board. Please also note that 
  627. you cannot have two VGA boards in the same system.
  628.  
  629.  
  630.  
  631.  
  632. Figure 3.7 - Font Selection Menu
  633.  
  634. Choose Single, to run AutoCAD in the standard single screen mode, using a video 
  635. mode switch to standard VGA text mode during a flip screen. To eliminate the 
  636. video mode switch to text mode and back into high resolution graphics, choose 
  637. Text Window on Single to configure the single screen to use a graphics mode text 
  638. window. Using graphics mode to display text allows an instantaneous return from 
  639. a flip screen. The graphics text window is especially useful when using large 
  640. monitors which tend to be slow when switching modes. A SHELL command will 
  641. switch to text mode regardless of the setting.
  642.  
  643. TurboDLDClassic  offers you a selection of fonts to use for AutoCAD menus, 
  644. pull-downs, and dialog boxes (see Figure 3.7). Provided by Panacea are 6x8, 8x8, 
  645. 8x14, 8x16, 12x20 and 12x24 font options. Also available for use are any of the 
  646. .BDF fonts, included with AutoCAD Release 12, you may have on your system. 
  647. For resolutions over 800x600 we recommend the 12x20 or 12x24 fonts.
  648.  
  649. To make a font selection, highlight Select Font From List to display a list of 
  650. available fonts. Use the Up and Down arrow keys, and the Pg Up and Pg Dn keys 
  651. to scroll through the list and highlight the font you wish to use. Press the ENTER 
  652. key to return to the Basic Configuration menu. To limit the available font choices, 
  653. choose the Select Font Filter menu selection to choose a .BDF font type from 
  654. those listed (see Figure 3.8). When you return to the Select Font From List option 
  655. again, only those files matching the filter name will be available for use.
  656.  
  657. If you do not see any .BDF font selections listed in the Basic Configuration menu, 
  658. you will need to add the following line to your AutoCAD start-up batch file.
  659. SET DLDFONT =C:\ACAD\DRV
  660.  
  661. Highlight Return To Previous Menu and press the RETURN key to return to the 
  662. Main Configuration Menu.
  663.  
  664.  
  665. User Interface Menu
  666.  
  667. The User Interface options configure the productivity features of 
  668. TurboDLDClassic (see Figure 3.9). These features change the way you manuever 
  669. around AutoCAD and execute commands.
  670.  
  671. Figure 3.8 - Font Filter Menu
  672.  
  673. Double Click Timing
  674.  
  675. The first timing option sets the Double Click delay. This time represents the 
  676. largest amount of time that can elapse between the release of the digitizer button 
  677. and the subsequent press of the same button in order to detect a double click. 
  678. Setting this number too low may result in the computer seeing two separate clicks, 
  679. while setting the time too high may slow down response time for single button 
  680. presses. Values between 10 and 30 are recommended.
  681.  
  682. Double Click time is measured in hundredths of seconds. PC systems have a 
  683. timing resolution of 5/100ths of a second, therefore, the entered time is rounded 
  684. internally by the driver to most closely approximate the nearest multiple of 5. This 
  685. means that a time setting of 23 is the same as a setting of 27, both of which get 
  686. rounded to 25 (or one-quarter of a second). In simplest terms, when adjusting 
  687. these values, it is best to use multiples of 5.
  688.  
  689.  
  690.  
  691. Figure 3.9 - User Interface Menu
  692.  
  693. Big Picture Options
  694.  
  695. The Big Picture, Panacea's bird's-eye view, can be configured to suit your needs or 
  696. allow for better differentiation within a complex drawing.
  697.  
  698. At the BP Button menu option, enter the number of the button on your mouse or 
  699. tablet that you wish to use as your bird's eye "hot key". A Double Click on that 
  700. button will cause TurboDLDClassic's bird's eye to pop-up on -screen.
  701.  
  702. BP Highlight controls how the current viewport reference in the Big Picture 
  703. appears on the screen. Patt Line displays the viewport reference using dotted 
  704. lines. XOR Rect uses a contrasting rectangle to display the viewport reference. 
  705. The Both option will use a combination of Patt Line and XOR Rect to display the 
  706. viewport reference.
  707.  
  708. In its fastest mode, TurboDLDClassic only refreshes the Big Picture when objects 
  709. are added to a drawing, until a DLDREFRESH command is issued. Moved or 
  710. erased objects will remain in the Big Picture. Depending on a drawing's 
  711. complexity, if BP Refresh is Disabled, the Big Picture could become confusing, 
  712. displaying vectors that are actually erased, and no longer part of the drawing. To 
  713. configure the Big Picture to be updated as objects are drawn AND erased, 
  714. ENABLE the BP Refresh. If speed is a major concern, DISABLE it.
  715.  
  716. Highlight Return To Previous Menu and press the RETURN key to return to the 
  717. Main Configuration Menu.
  718.  
  719.  
  720. Expert Configuration Menu
  721.  
  722. The Expert Configuration menu sets the basic internal functions of 
  723. TurboDLDClassic. Options in this menu allow for customization of the driver for 
  724. speed or to adjust for memory constraints (see Figure 3.10).
  725.  
  726. Display List enables or disables the display list feature of TurboDLDClassic', the 
  727. core of the driver's AutoCAD performance boost. This option should always be set 
  728. to ENABLE, as disabling the Display List will cause TurboDLDClassic to run as 
  729. an ordinary non-display list driver.
  730.  
  731. Use AutoCAD 31-bit Space, configures TurboDLDClassic for use with 
  732. AutoCAD R12's 31-bit logical drawing space. When set to Yes, the driver will use 
  733. AutoCAD's extended 31-bit drawing space. Selecting No, will use a 15-bit 
  734. drawing space, similar to that of AutoCAD R10/R11.
  735.  
  736. The 31-bit logical space allows you to extend your Regen-less zooming ability by 
  737. a factor of several million, at the cost of more memory. Additional memory is used 
  738. by AutoCAD for the drawing space, and by TurboDLDClassic for the Display 
  739. List. 31-bit zooming and panning is about 10%-20% slower than for 15-bit logical 
  740. space.
  741.  
  742. The Use AutoCAD 31-bit Space setting is ignored for AutoCAD R10/R11 
  743. installations as these versions only support a 15-bit logical drawing space. 
  744.  
  745. The echo of TurboDLDClassic internal commands can be enabled or disabled with 
  746. the Internal Command Echo option. If you would like to see TurboDLDClassic's 
  747. internal commands display at the AutoCAD command line as they are executed, 
  748. enable this option.
  749.  
  750. BP Zoom Mode sets the Big Picture (BP) zoom definition area display options. In 
  751. a zoomed view of the static BP, as the current viewport is zoomed or panned, 
  752. FLOAT mode causes the image in the BP to move around within the bird's-eye 
  753. window, keeping the zoomed viewport area fixed in the center of the bird's-eye. 
  754. FREEZE mode will lock the current BP contents into place to provide a better 
  755. overall frame of reference.
  756.  
  757. After all Expert options have been set, highlight Return To Previous Menu and 
  758. press the RETURN key to return to the Main Configuration Menu.
  759.  
  760.  
  761.  
  762. Figure 3.10 -Expert  Configuration Menu
  763.  
  764. Saving Configuration Information
  765.  
  766. Once all of the TurboDLDClassic parameters have been configured, select SAVE, 
  767. EXIT to save the configuration information and create DLDSETUP.DAT, 
  768. DLXBUTTN.DAT, and DLXMENUS.DAT in either the ACAD\DRV sub-
  769. directory (R12) or the TURBODLD (R10/R11) sub-directory. DLDSETUP.DAT 
  770. is TurboDLDClassic's configuration file while DLXBUTTN.DAT and 
  771. DLXMENUS.DAT are the configuration files for the digitizer buttons and pop-up 
  772. menus, respectively.
  773.  
  774. After answering AutoCAD's standard driver configuration questions (see Figure 
  775. 3.11), you will return back to the AutoCAD configuration menu. To begin your 
  776. accelerated AutoCAD, for AutoCAD R12, select option 0, Exit to Drawing 
  777. Editor; for AutoCAD R10/11, choose option 1 or 2, Open New/Existing 
  778. Drawing.
  779.  
  780. Figure 3.11 - AutoCAD Screen  Configuration Options
  781.  
  782. Verifying Your TurboDLDClassic Installation
  783.  
  784. To verify that TurboDLDClassic is running and installed correctly, follow one of 
  785. these two simple tests.
  786.  
  787. ∙    If you have the AutoCAD side menu enabled, look for the Panacea Logo in the 
  788.     lower right-hand corner.
  789.  
  790. ∙    If you are running AutoCAD without a side menu, type DLDVER at the 
  791.     AutoCAD command prompt. If TurboDLDClassic is loaded and running, this 
  792.     command should return your current version, serial number and the registered 
  793.     user's name.
  794.  
  795. ∙    If TurboDLDClassic was not correctly installed, you will receive an AutoCAD 
  796.     error when the DLDVER command is entered.
  797.  
  798.  
  799. Reconfiguring TurboDLDClassic
  800.  
  801. To reconfigure TurboDLDClassic follow the instructions for AutoCAD Release 
  802. 12 or Release 11/10 below.
  803.  
  804. AutoCAD Release 12
  805.  
  806. If you need to make changes to your Release 12 TurboDLDClassic configuration, 
  807. type CONFIG at the AutoCAD command prompt or use ACAD -R when starting 
  808. the program. Select option 3, Configure Video Display. Answer No to the "Select 
  809. a new video driver ..." prompt to start the TurboDLDClassic configuration 
  810. program. Make the desired changes to the driver and then Save and Exit to 
  811. continue to the AutoCAD drawing editor.
  812.  
  813. AutoCAD Release 10/11
  814.  
  815. To change a Release 10/11 configuration, select option 5, Configure AutoCAD 
  816. from the AutoCAD main menu. and then from the configuration menu, select 
  817. option 3, Configure Video Display. Answer No to the "Select a new video 
  818. driver..." prompt to start the TurboDLDClassic configuration program. Change 
  819. the desired driver options. Save and Exit to return to the AutoCAD configuration 
  820. menu. Open or begin a new drawing. 
  821.  
  822. To completely reconfigure TurboDLDClassic using the defaults, delete 
  823. DLDSETUP.DAT, DLXBUTTN.DAT, and DLXMENUS.DAT from either the 
  824. \ACAD\DRV sub-directory (R12) or the TURBODLD sub-directory (R10/11) and 
  825. then follow the Driver Configuration instructions at the beginning of this chapter.
  826.  
  827. Configuring The AutoCAD R10/11 Operating Environment
  828.  
  829. During the TurboDLDClassic installation process, a FASTACAD.BAT file is 
  830. created and placed into the TURBODLD sub-directory. FASTACAD.BAT 
  831. contains four lines that set four separate environment variables: DLDCFG - used 
  832. by TurboDLDClassic to find all of its configuration files; and DSPADI, RCPADI, 
  833. RDPADI  - used by AutoCAD, 3D Studio and AutoShade 2 w/RenderMan, 
  834. respectively, to find the driver file. FASTACAD.BAT must be run prior to starting 
  835. AutoCAD R10 or R11 and only needs to be run once per system boot. For 
  836. automatic loading of the environment variables, FASTACAD.BAT may be added 
  837. to the AUTOEXEC.BAT file or an AutoCAD start-up batch file. 
  838.  
  839. To add execution of FASTACAD.BAT to your AUTOEXEC.BAT file, insert the 
  840. line
  841.  
  842. CALL D:\TURBODLD\FASTACAD
  843.  
  844. anywhere in the file.  The above example assumes that FASTACAD.BAT resides 
  845. in a sub-directory on drive D: called \TURBODLD.
  846.  
  847.  If you don't wish to put FASTACAD in your AUTOEXEC.BAT file, you may 
  848. put it in a batch file which also starts AutoCAD, or simply remember to run the 
  849. file before starting AutoCAD. (You should also stop using any other ADI display 
  850. driver that may have come with your graphics board, since TurboDLDClassic is a 
  851. superset of that type of driver).
  852.  
  853.  
  854. If you get the message
  855.  
  856. Out of Environment Space
  857.  
  858. when you run FASTACAD.BAT, you will need to enlarge your system's 
  859. environment. This is accomplished by adding the following line,
  860.  
  861. SHELL=C:\COMMAND.COM /P /E:768 
  862.  
  863. to your CONFIG.SYS file. The /E:768 specifies an environment size of 768 
  864. bytes. Change this number as appropriate. You will need to reboot if you modify 
  865. your CONFIG.SYS file, in order for the changes to take effect.  
  866.  
  867. Configuring TurboDLDClassic for Rendering
  868.  
  869. To install and configure TurboDLDClassic for use with AutoCAD R12's AVE 
  870. Render, 3D Studio or AutoShade 2 w/RenderMan, please read Chapter 8 - 
  871. Rendering with TurboDLDClassic.
  872.  
  873.  
  874.  
  875. Chapter 4
  876.  
  877. Changing
  878. Colors
  879.  
  880. Included with TurboDLDClassic, is the  revolutionary CustomColors color 
  881. configuration utility. What's so unique about CustomColors is that it gives you the 
  882. ability to modify all your changeable AutoCAD colors, including menu colors, 
  883. text colors, dialog box colors, and even drawing colors, while running AutoCAD.
  884.  
  885. CustomColors simulates an AutoCAD screen, complete with all possible objects. 
  886. At the AutoCAD drawing editor command line, type  DLDCOLOR to edit the 
  887. color configuration. 
  888.  
  889. If you have configured TurboDLDClassic for 256 colors, you will be greeted with 
  890. an informational warning message. The message appears to remind you that if you 
  891. assign a drawing color to a physical color above color 15, you may experience 
  892. unusual results from AVE Render.
  893.  
  894. Once you enter the utility, you are provided with the following configuration 
  895. menu at the bottom of the screen:
  896.  
  897. (O)bject, 
  898. (D)rawing, 
  899. (P)hysical, 
  900. (A)DI reset, 
  901. (V)GA reset, 
  902. (L)oad, 
  903. (S)ave, 
  904. (E)xit
  905.  
  906. Figure 4.1 - DLDCOLOR
  907.  
  908.     The menu items perform the following functions.
  909.  
  910. Object    
  911.  
  912. Selecting this option will allow you to change the color of any AutoCAD screen 
  913. object, such as the graphics area background color, the menu area text color, or the 
  914. border line color.
  915.  
  916. Select the screen object whose color you want to change by moving the highlight 
  917. box around with the left, right, up and down cursor control keys. Press ENTER 
  918. when you have highlighted the desired object. Note that a one line description of 
  919. the object type is displayed at the top of the screen as you move the box around.
  920.  
  921. Once you have selected the object, another highlight box will appear around the 
  922. color boxes nearest the bottom of the screen. These are the physical colors that the 
  923. video board supports. Use the left and right cursor keys to select the physical color 
  924. to be used for the object you have selected and press ENTER. The screen will 
  925. quickly redraw with the new color selection for the object you have chosen, and 
  926. you will be back at the start of object selection in case you want to change the 
  927. color of another object.
  928.  
  929. Note that at any time during color configuration, you can press the ESC key once 
  930. or twice and return to AutoCAD. Also, pressing the question mark ("?") key will 
  931. provide you with context sensitive help.
  932.  
  933. Drawing    
  934.  
  935. This 16 color configuration option allows you to modify all AutoCAD drawing in 
  936. a fashion similar to the way you change object colors. 
  937.  
  938. When this option is selected, a highlight square appears in the drawing color area 
  939. of the simulated AutoCAD display. The square can be manipulated using the four 
  940. cursor keys. You may notice that the drawing color portion of the display is laid 
  941. out just like the CHROMA drawing supplied with AutoCAD. When you press 
  942. ENTER, the highlight moves down to the 16 physical colors, just as it does during 
  943. the object color selection. Using the arrow keys, pick the physical color you want 
  944. to represent the selected drawing color. Press ENTER for your selection to take 
  945. effect. When using 256 colors, you do not have a (D)rawing Color option. All 256 
  946. colors are available as drawing colors. 
  947.  
  948. Physical    
  949.  
  950. Choosing the Physical option from the menu allows you to alter the red, green, and 
  951. blue components of the physical colors. A highlight box will appear in the row of 
  952. 16 physical colors at the bottom of the screen.
  953. Use the arrow keys to select the color you wish to edit and press ENTER. Three
  954. "sliders" will appear near the bottom of the display, with the horizontal position of 
  955. the slider for each of the color components (red, green, or blue - RGB) indicating 
  956. the relative intensity of the component. You can use the left and right arrow keys 
  957. to move the slider for the selected component, or type in a number from 0 to 255. 
  958.  
  959. Many graphics boards do not support 255 different intensities for each color 
  960. component. Therefore, when you enter an intensity, Custom Colors will round it to 
  961. the nearest intensity which your graphics board supports.
  962.  
  963. For example, VGAs support 64 intensities per RGB color component. This means 
  964. intensities increase in multiples of 4 (256/64), therefore an intensity of 0 is the 
  965. same as an intensity of 3.
  966.  
  967. The up and down arrows allow you to select which component you want to alter. 
  968. As you manipulate the sliders, all objects on the displaythat are of the same color 
  969. as the selected physical color will change in hue. This way you can visually 
  970. determine the most appropriate setting for your display. Pressing ENTER will set 
  971. the RGB values you have selected for the physical color you were modifying.
  972.  
  973. ADI reset    This constructs a default ADI color palette, as defined in the Autodesk Device 
  974.         Interface Driver Development Kit shipped with AutoCAD Release 12.
  975.  
  976. VGA reset    This constructs a default VGA color palette in the first 16 color entries. The 
  977.         remaining palette colors remain identical to those used for ADI devices
  978.  
  979. Load        This reloads the color information from the file DLDCOLOR.DAT. It will be 
  980.         loaded from the directory pointed to by DLDCFG (AutoCAD R10/R11), or from 
  981.         the AutoCAD R12 \DRV directory. If DLDCOLOR.DAT cannot be found, an 
  982.         error message will be displayed.
  983.  
  984. This command is useful because it allows you to go back to your previously edited 
  985. color configuration in case you have made some mistakes in configuring your 
  986. colors that you want to undo. 
  987.  
  988. Don't Accidently Wipe Out Your Changes
  989.  
  990.  
  991. Selecting ADIreset, VGAreset, or Load will irrevocably wipe out any current 
  992. color changes you may have made, unless you have just saved your new setting, so 
  993. use them only when you really need to, such as when you have made so many 
  994. color changes that you can't seem to get back to a reasonable place and just want 
  995. to start over.
  996.  
  997. Save        Saves the current color palette to DLDCOLOR.DAT. It will be saved to the 
  998.         directory pointed to by the DLDCFG environment variable in FASTACAD, or to 
  999.         the \ACAD\DRV (R12) directory if FASTACAD is not used.
  1000. Exit        Exits CustomColors. If you have made palette changes, but not saved them, you 
  1001.         will be asked if you want to save your changes before exiting.
  1002.         When running at more than 8 bits-per-pixel (256 colors), setting physical colors 
  1003.         via DLDCOLOR will have no visible effect until a SAVE and EXIT occurs.
  1004.  
  1005.  
  1006.  
  1007.  
  1008.  
  1009.  
  1010. TurboDLD
  1011. Features
  1012.  
  1013. TurboDLDClassic offers AutoCAD users many features and productivity options. 
  1014. This chapter alphabetically lists the basic commands found in all TurboDLD 
  1015. versions and provides the correct syntax for their usage. For a brief summary of 
  1016. TurboDLDClassic commands, see Appendix B or while running AutoCAD, type 
  1017. DLDHELP at the command prompt.
  1018.  
  1019. Please note that the commands above with a "*" following them, when issued 
  1020. within AutoCAD, will override the selections made during TurboDLDClassic 
  1021. configuration, for the current drawing session only. Exiting AutoCAD and 
  1022. subsequently restarting will cause all feature settings to revert back to those 
  1023. selected in the TurboDLDClassic configuration menu. If you wish to make the 
  1024. current changes permanent, reconfigure TurboDLDClassic by following the 
  1025. reconfiguration instructions in Chapter 3.
  1026.  
  1027. The Big Picture    
  1028.  
  1029. The most important feature of TurboDLDClassic is the support of a world view 
  1030. called The Big PictureTM or just BP for short. Bringing up the BP allows you to 
  1031. view where in the current drawing you are currently located in your active 
  1032. viewport, and it also gives you the ability to dynamically move to another part of 
  1033. the drawing without having to exit the function you're currently executing.
  1034.  
  1035. DLDBIGPIC    
  1036.  
  1037. To call up the Big Picture, at the AutoCAD command line, type DLDBIGPIC, or 
  1038. double click the right mouse button or button 2  on your digitizer puck (assuming 
  1039. you haven't redefined your Button 2 double click function - see Chapter 3). This 
  1040. will bring up the BP on the display. You will see cross-hairs and a highlighted 
  1041. section indicating which part of the whole drawing you're currently viewing - the 
  1042. size of the image will be determined by the AutoCAD logical drawing space being 
  1043. used, 15-Bit or 31-Bit. The selection or pick box will have an "X" through it. 
  1044. Move the mouse/digitizer around to locate your pick box. If you can't see a small 
  1045. box moving, click the left mouse button (the pick button) to size down the pick 
  1046. area. In size mode, the pick box will have a right pointing arrow in it  ("-->"). If 
  1047. the contents of the BP are too small to work with, you may increase the size of the 
  1048. image in the window by pressing the "+" key on your numeric keypad this 
  1049. performs an incremental zoom within the BP. Likewise, pressing the "-" key will 
  1050. reduce the size of the contents of the BP. Pressing the HOME and END keys will 
  1051. put the BP into its smallest and largest size, respectively. The smallest BP size is 
  1052. defined as being exactly the same view as that in the viewport referenced by the 
  1053. BP.  The largest BP size is defined as the largest image possible without causing a 
  1054. Regen.
  1055.  
  1056. The BP pick box is always proportioned to the proper aspect ratio for the current 
  1057. viewport. Clicking the pick button again will put you back into the pick box move 
  1058. mode ("X"). This operation is very similar to using the Zoom Dynamic feature of 
  1059. AutoCAD. Once you havepositioned the pick box on the area you would like 
  1060. displayed in the active viewport, click any button other than the pick button to 
  1061. initiate the zoom, or press the Enter key. If you want to abort the operation, just 
  1062. hold any mouse or digitizer button down, other than the pick button, until the BP 
  1063. disappears. You can also hit any key on the keyboard, other than Enter, to cancel 
  1064. the BP.
  1065.  
  1066. The BP is updated with new drawing commands. Moves or erases will not update 
  1067. the image unless BPREFRESH is enabled. A DLDREFRESH or a REGEN will 
  1068. manually update the BP with the current drawing changes.
  1069.  
  1070. DLDBPDIM    
  1071.  
  1072. Resizing and repositioning the BP can be accomplished by typing this command at 
  1073. the AutoCAD prompt. DLDBPDIM allows you to tell the driver where you want 
  1074. the BP placed and how large you want it to be. The size is limited to being 
  1075. between one-quarter and one-half the width of the display. This command 
  1076. functions like the pan/zoom selection box in the BP, as far as positioning and 
  1077. dimensioning goes. To abort, hold the right mouse button, or any other digitizer 
  1078. button, down until the moving box disappears.
  1079.  
  1080. DLDBPFREEZE    
  1081.  
  1082. Sets the Big Picture (BP) zoom definition area display options. DLDBPFREEZE 
  1083. toggles the Big Picture Zoom Mode parameter in TurboDLDClassic's Expert 
  1084. Configuration Menu.
  1085.  
  1086. In a zoomed view of the static BP, as the current viewport is zoomed or panned, 
  1087. Float mode causes the image in the BP to move around within the bird's-eye 
  1088. window, keeping the zoomed viewport area fixed in the center of the bird's-eye. 
  1089. Freeze mode will lock the current BP contents into place to provide a better 
  1090. overall frame of reference.
  1091.  
  1092. DLDBPHILIGHT*    
  1093.  
  1094. Changes the highlight used to display the Big Picture among three modes, Patt 
  1095. Line, XOR Rect, and Both. Patt Lines will use dotted lines to outline the Big 
  1096. Picture pick box. XOR Rect will use a contrasting rectangle to highlight the pick 
  1097. box, and Both will use a combination of Patt Lines and XOR Rect.
  1098.  
  1099. DLDBPMODE    
  1100.  
  1101. Toggles the Big Picture between Panning and Zooming modes. In panning mode, 
  1102. the AutoCAD drawing will dynamically display the contents of the Big Picture 
  1103. pick box as you size and move it. In Zoom mode, the AutoCAD drawing remains 
  1104. stationary until the area in the Big Picture pick box is accepted. At which time it 
  1105. changes to the chosen zoom level.
  1106.  
  1107. DLDBPREFRSH*    
  1108.  
  1109. This convenience feature of TurboDLDClassic, toggles the Big Picture update 
  1110. mode. If disabled, the BP is updated manually by issuing a DLDREFRESH 
  1111. command. When enabled, DLDBPREFRSH will cause the BP to refresh 
  1112. automatically when an object is drawn or erased. The BP operations therefore will 
  1113. be slower with DLDBPREFRSH enabled.
  1114.  
  1115. DLDBPSTATIC    
  1116.  
  1117. Toggles the BP to stay on the screen at all times. Use this command if you want 
  1118. the BP on the screen in order to conveniently move into it whenever you want to 
  1119. zoom or pan. Typing  DLDBPSTATIC will put up the BP at the position you set 
  1120. with DLDBPDIM.
  1121.  
  1122. The static BP will disappear when other menus pop-up on the screen, and it will 
  1123. also disappear if you draw any objects which may overwrite the BP. With these 
  1124. exceptions, the BP will remain on-screen until you either exit the drawing screen 
  1125. or you type DLDBPSTATIC again.
  1126.  
  1127. DLDCOLOR    
  1128.  
  1129. Invokes CustomColorsTM, the color configuration program. See Chapter 4 - 
  1130. Configuring Colors for more information on configuring TurboDLDClassic 
  1131. colors.
  1132.  
  1133. DLDCOMPACT
  1134.  
  1135. Forces a manual garbage collect of Display List memory thereby returning unused 
  1136. display list memory back to the AutoCAD memory pool.
  1137.  
  1138. DLDDLIST*    
  1139.  
  1140. This command toggles the display list function of TurboDLDClassic on and off.
  1141. Please note that if the display list is turned off, you will be running AutoCAD as 
  1142. though you were using a standard non display list driver - pans, zooms and 
  1143. redraws will be MUCH slower with DLDDLIST disabled.
  1144.  
  1145. DLDECHO*    
  1146.  
  1147. Toggles internal TurboDLDClassic command echoing at the AutoCAD command 
  1148. line. When TurboDLDClassic commands are executed via the digitizer or pop-up 
  1149. menus, they generate internal commands which will be displayed at the AutoCAD 
  1150. command line if DLDECHO is enabled. Disable DLDECHO to simplify the 
  1151. command line.
  1152.  
  1153. DLDHELP    
  1154.  
  1155. Provides a list of TurboDLDClassic commands with one-line description of each, 
  1156. within AutoCAD. It's recommended that you flip to the text screen by pressing the 
  1157. <F1> key to view the output.
  1158.  
  1159. DLDREFRESH    
  1160.  
  1161. Refreshes the Big Picture to reflect the most current changes to a drawing. If the 
  1162. static BP is up, it will be updated.  If not, the next time the BP is brought up, it 
  1163. will contain a current representation of your drawing, provided no changes were 
  1164. made between the DLDREFRESH command and the DLDBIGPIC command. For 
  1165. Automatic update of the Big Picture, see the DLDBPREFRSH command above.
  1166.  
  1167. DLDSAVECFG    
  1168.  
  1169. The DLDSAVECFG command saves the current TurboDLDClassic configuration 
  1170. for use in a later AutoCAD drawing session. The size, location and operating 
  1171. mode of the Big Picture are saved with this command. DLDSAVECFG creates a 
  1172. file named DLXSTATE.DAT, in the directory that TurboDLDClassic was 
  1173. installed in. DLXSTATE.DAT may be deleted in order to return the above 
  1174. features to TurboDLDClassic's default settings.
  1175.  
  1176. DLDSTAT    
  1177.  
  1178. Displays the current TurboDLDClassic status. A listing of the current 
  1179. TurboDLDClassic parameters is displayed at the AutoCAD command line. A flip 
  1180. to the graphics screen is recommended to view the status report. 
  1181.  
  1182. DLDUSAGE    
  1183.  
  1184. Use DLDUSAGE if you want a to-the-byte breakdown of how memory is being 
  1185. used,  specifically for display list processing. DLDUSAGE returns information 
  1186. regarding the memory each viewport is occupying. Since AutoCAD supports 
  1187. multiple viewports, it is possible to have multiple display lists. A new or empty 
  1188. drawing will have a display list of 4k bytes.
  1189.  
  1190. DLDVER    
  1191.  
  1192. Displays the TurboDLDClassic version, serial number and registered user's name 
  1193. at the AutoCAD command line.
  1194.  
  1195. DLDZMVMAX    
  1196.  
  1197. TurboDLDClassic supports a REGEN-less Zoom ALL capability, identical to 
  1198. AutoCAD's Zoom VMAX command. Just type DLDZMVMAX at the AutoCAD 
  1199. prompt, and the current viewport will zoom to its full size. This function is 
  1200. designed primarily for AutoCAD Release 10/386 users, who do not have an 
  1201. AutoCAD command to do this.
  1202.  
  1203. PD, ZD, ZW    
  1204.  
  1205. PD - Pan Dynamic, ZD - Zoom Dynamic and ZW - Zoom Window are included in 
  1206. TurboDLDClassic for backwards compatibility with MACH-12. These commands 
  1207. will invoke the Big Picture.
  1208.  
  1209. ZI, ZO    
  1210.  
  1211. ZI - Zoom In and ZO - Zoom Out will zoom the current viewport in or out 
  1212. incrementally.
  1213.  
  1214.  
  1215. Chapter 6
  1216.  
  1217. Memory Usage 
  1218. and 
  1219. Lists
  1220.  
  1221. TurboDLDClassic shares extended memory with AutoCAD via the PharLap 
  1222. Virtual Memory Manager. This means that TurboDLDClassic will automatically 
  1223. page to disk if it uses up all the RAM that AutoCAD has left for its use. See the 
  1224. AutoCAD "Installation and Performance Guide" for more information on Virtual 
  1225. Memory Management. 
  1226.  
  1227. If you start seeing excessive hard disk accesses during PANs, REDRAWs, and 
  1228. ZOOMs while using AutoCAD with TurboDLDClassic, try using the 
  1229. DLDCOMPACT command. If this doesn't affect the amount of disk access it's 
  1230. probably time to add more memory to your system. Contact your AutoCAD dealer 
  1231. for assistance in upgrading your memory.
  1232.  
  1233. Regarding display list memory, it's important to realize that TurboDLDClassic 
  1234. speeds up AutoCAD operations by creating a Display List in memory, and sending 
  1235. that list to the graphics board for pans, zooms and redraws. But a display list takes 
  1236. up memory.
  1237.  
  1238. How much memory?    
  1239.  
  1240. For production use, we recommend that at least 1 megabyte is available for 
  1241. TurboDLDClassic.  To determine how much memory AutoCAD is using, use the 
  1242. status command while in AutoCAD (refer to the AutoCAD "Installation and 
  1243. Performance Guide" for more information). The Display List for a simple drawing 
  1244. like the shuttle Columbia might only require 20 Kbytes for the Display List.  
  1245. Complex drawings may require several megabytes.  We have seen Display Lists 
  1246. for a drawing range from one-tenth the size of the drawing file to three times the 
  1247. size; in general, the Display List averages about one and one-half times the size of 
  1248. the DWG file size. This means that you should reserve approximately two and 
  1249. one-half times your average DWG file size in RAM for the drawing and the 
  1250. Display List.  Also, complex objects such as circles and text "expand" when 
  1251. translated into display list format, so a drawing with a lot of complex objects and 
  1252. text will have a larger Display List than a simpler drawing. 
  1253.  
  1254. If there is significant hard disk activity while you are using TurboDLDClassic, it 
  1255. may be an indication that you should add more memory to your system.
  1256.  
  1257. Text takes up a disproportionate amount of space in the Display List.  To keep the 
  1258. list small, put text in its own layer of the drawing.  Then don't display the text 
  1259. layer when editing the rest of the figure.  This will keep memory consumption 
  1260. down and speed up PANs, REDRAWs, and ZOOMs.
  1261.  
  1262. The AutoCAD manuals have an excellent section on performance, concentrating 
  1263. on memory usage.  To get the most performance out of the program, read the 
  1264. appropriate sections of those manuals as well as this one.  
  1265.  
  1266.  
  1267. Chapter 7
  1268.  
  1269. Tips,
  1270. Tricks &
  1271. Trouble-
  1272. shooting
  1273.  
  1274. Because TurboDLDClassic supports such a wide range of graphics board 
  1275. platforms, it is necessary to be aware of certain idiosyncrasies. This chapter 
  1276. outlines known configuration and usage problems of TurboDLDClassic and of 
  1277. various graphics platforms. Also included are tips to help gain performance from 
  1278. AutoCAD itself. These tips and tricks are a compilation of the most commonly 
  1279. asked Technical Support questions. Therefore, if you are having problems, please 
  1280. review this chapter, you may be able to quickly answer your own question.
  1281.  
  1282. Memory Management
  1283.  
  1284. System lock-ups, random re-boots or missing displays, indicate you may have a 
  1285. memory conflict on your system. Different video platforms access different, 
  1286. specific, portions of upper memory blocks. If these memory addresses are in use 
  1287. by TSRs or other programs or memory managers, the above symptoms will occur. 
  1288. To avoid these problems it is necessary to use an expanded memory manager to 
  1289. allocate the specific address range to the graphics board. The address to exclude 
  1290. usually falls within the range of A000 to C7FF. 
  1291.  
  1292. Some common expanded memory managers are QEMM, 386MAX and EMM386 
  1293. (which comes with DOS 5.0 and later and Windows).
  1294.  
  1295. QEMM and EMM386 use similar commands to perform the exclusion.
  1296.  
  1297.     X=B000-B7FF
  1298.  
  1299. is added to the QEMM386.SYS or EMM386.EXE command line in the 
  1300. CONFIG.SYS file.
  1301.  
  1302. 386MAX uses a video memory parameter which look like this
  1303.  
  1304.     VIDMEM=B000-B7FF
  1305.  
  1306. Note that it may be necessary to run an optimization utility with some memory 
  1307. managers in order for the exclusion to take effect. Refer to your memory 
  1308. manager's documentation for specific details.
  1309.  
  1310. If the range of A000-C7FF seems like a large area to exclude, you may  decrease 
  1311. the range by changing the ending address to determine the exact range that you 
  1312. need to exclude. Typically B000-B7FF, as shown in the examples above, will be 
  1313. sufficient. You may try other ranges, by altering the beginning and/or ending 
  1314. address, to isolate the exact region the graphics board requires. Remember to re-
  1315. boot after changing the CONFIG.SYS file. Some common requirements are shown 
  1316. below.
  1317.  
  1318. Due to the manner in which they re-map video BIOS memory regions in RAM, 
  1319. memory optimization utilities, such as QEMM's Stealth and EMM386's 
  1320. HIGHSCAN, should be avoided.
  1321.  
  1322. XGA 
  1323.  
  1324. XGA-based graphics boards must have at least the range of B000-DFFF available.
  1325.  
  1326. SVGA 
  1327.  
  1328. SVGA boards usually use the area of B000-B7FF.
  1329.  
  1330. Upgrading  From Older DLD Drivers
  1331.  
  1332. Be sure to remove any reference to previous DLD driver commands (FASTACAD 
  1333. calls or SET DLDCFG, RCPADI, RDPADI and DSPADI parameters) or sub-
  1334. directories that may be in your AUTOEXEC.BAT file or in AutoCAD start-up 
  1335. batch files. Such references could cause AutoCAD and TurboDLDClassic to look 
  1336. in the wrong place for setup information.
  1337.  
  1338. If have been using a previous DLD driver and wish to use the color palette you 
  1339. customized for it with TurboDLDClassic, you may copy the DLDCOLOR.DAT 
  1340. file from your older DLD's sub-directory to the sub-directory you specified during 
  1341. the TurboDLDClassic installation process.
  1342.  
  1343. Maneuvering Through AutoCAD
  1344. Zooming
  1345. Watch the Snap
  1346.  
  1347. When zooming into an image, be aware of your AutoCAD grid snap setting. If you 
  1348. are zoomed extremely far into a drawing and you are having trouble moving your 
  1349. digitizer cursor, you may be snapping to a  point which is not part of the zoomed 
  1350. viewport. If the cursor only moves to a single point, or is not on screen at all Snap 
  1351. might be turned on. Check the status bar to be sure. If you see "Snap" listed, press 
  1352. the F8 key to turn it off.
  1353.  
  1354. Zoom $1
  1355.  
  1356. An undocumented AutoCAD command can help speed up performance in some 
  1357. situations, ZOOM $1. ZOOM $1 will allow you to set the extents of AutoCAD 
  1358. Release 12's logical drawing space. by issuing the following command sequence:
  1359.  
  1360.     ZOOM
  1361.     $1
  1362.     CTRL-C
  1363.     CTRL-C
  1364.     CTRL-C
  1365.     CTRL-C
  1366.  
  1367. The catch is that the command is only in effect until a REGEN is issued. 
  1368.  
  1369. Be sure to zoom to the view of your drawing you wish to use as the extents before 
  1370. issuing the above. If you find this command to be useful, you may also want to try 
  1371. configuring for a 15-bit drawing space -- See Chapter 3 - Installing and 
  1372. Configuring, "Expert Configuration" menu. 
  1373.  
  1374. TurboDLDClassic and Paper Space
  1375.  
  1376. TurboDLDClassic features do not work in AutoCAD's Paper Space. The 
  1377. execution of any TurboDLDClassic command in Paper Space, due to a limitation 
  1378. in AutoCAD, will result in an error message at the command prompt.
  1379. Zoom Dynamic
  1380.  
  1381. We do not recommended using ANY Classic features while in the Zoom Dynamic 
  1382. mode of AutoCAD. Because TurboDLDClassic cannot detect when Zoom 
  1383. Dynamic has been initiated, unpredictable results will occur. Use the Big Picture 
  1384. feature of TurboDLDClassic to accomplish the same task as Zoom Dynamic, in a 
  1385. much more efficient fashion.
  1386.  
  1387. AutoCAD Release 12's CONFIG Command
  1388.  
  1389. Configuring TurboDLDClassic in the middle of a drawing session using the 
  1390. CONFIG command is a bit like exiting and re-starting AutoCAD. If are using the 
  1391. static Big Picture and wish to resume your drawing session with it on, issue the 
  1392. DLDSAVECFG command before issuing the CONFIG command.
  1393.  
  1394. Sticky Cursors
  1395.  
  1396.  In the Big Picture
  1397.  
  1398. Sometimes, when using the Big Picture, the digitizer cursor will appear to stick to 
  1399. the edge of the bird's-eye. This is normal and is the result of the digitizer puck 
  1400. responding to the whole screen area while the Big Picture only occupies a small 
  1401. portion of the screen. Because of the difference in resolutions between the screen 
  1402. and the digitizer, when the screen cursor enters the Big Picture area, the digitizer 
  1403. puck has more drawing area to cover in order to get to the same location as the 
  1404. screen cursor.
  1405.  
  1406. Within AutoCAD 
  1407.  
  1408. The following solutions have been used to fix slow mouse/digitizer response 
  1409. problems when using TurboDLD drivers.
  1410.  
  1411. ∙    Make sure that you are not using a real mode driver for your digitizer. Real-
  1412.     mode drivers do not interact properly with protected-mode drivers. 
  1413.     AutoCAD Releases 10/386, 11/386, and 12, are all protected-mode. We 
  1414.     recommended that you switch to either the AutoCAD supplied driver or the 
  1415.     manufacturer's latest ADI 4.2 driver for the digitizer.
  1416.  
  1417. ∙    Make sure that no digitizer key re-assigning TSR's are being used. Some 
  1418.     digitizers, specifically the Kurta IS/One, use TSR's to allow digitizer 
  1419.     programming; these will not work with TurboDLD.
  1420.  
  1421. ∙    Try deleting all files with a .DAT extension from your TurboDLD sub-
  1422.     directory and re-configuring TurboDLD from scratch. Occasionally, these 
  1423.     .DAT files can be corrupted or updated improperly during installation or 
  1424.     reconfiguration. 
  1425.  
  1426. ∙    Try changing the double-click interval time to 5 or 10. This can be adjusted 
  1427.     from the User Interface Menu of TurboDLD.
  1428.  
  1429. ∙    If a specific digitizer key is causing a problem, use the Delete key to 
  1430.     remove any AutoCAD commands from that button. Button programming 
  1431.     commands are in the User Interface menu within the Button Configuration 
  1432.     Menu. Be sure to use the Delete key, not Spaces to remove existing 
  1433.     commands. 
  1434.  
  1435. ∙    Depending on the digitizer you are using and how it is configured, try 
  1436.     adjusting CFIG386's -VSCAN parameter. Check the AutoCAD "Interface, 
  1437.     Installation and Performance Guide"  for specific instructions on how to 
  1438.     use CFIG386. 
  1439.  
  1440. ∙    Try using the CFIG386- DEMANDLOAD ON setting for AutoCAD.
  1441.  
  1442. ∙    If there is one available, try to duplicate the problem with a second mouse 
  1443.     or digitizer, this will help to isolate the cause of the problem.
  1444.  
  1445. ∙    If your digitizer is capable of it, try configuring for SummaSketch 
  1446.     emulation and use the driver included with AutoCAD.
  1447.  
  1448. ∙    If there is a choice in your digitizer's configuration, try configuring it for 
  1449.     Polled vs. Interrupt driven, or vice versa.
  1450.  
  1451. Using AutoCAD Commands
  1452.  
  1453. Since TurboDLDClassic is totally transparent to users with respect to using 
  1454. normal AutoCAD commands to REDRAW, PAN, and ZOOM, you still have to 
  1455. suffer from some of AutoCAD's nuances. One of these nuances is that ZOOM 
  1456. ALL and ZOOM EXTENTS both force a REGEN, because AutoCAD does not 
  1457. keep track of various boundaries necessary to avoid the REGENs. And REGENs 
  1458. are rather time-consuming and don't use any display list processing to speed 
  1459. themselves up. One way around this problem is to use another of AutoCAD's 
  1460. built-in features, namely the VIEW command.
  1461.  
  1462. When you first load your image and see the whole drawing on the screen at once, 
  1463. just type VIEW Save ALL, which will save the display position you see under a 
  1464. view named "All". Then, after you've done some detailed editing and want to 
  1465. return back to the big picture, type VIEW Restore ALL, instead of ZOOM All or 
  1466. ZOOM Extents, and the full drawing will be restored to the display at display list 
  1467. speeds, without a REGEN.
  1468.  
  1469. Another nuance of AutoCAD is that if you zoom in too far or pan over too far, you 
  1470. may inadvertently cause a REGEN. AutoCAD again provides a very simple 
  1471. solution: the REGENAUTO command. Just type REGENAUTO Off at the 
  1472. AutoCAD command prompt, and automatic REGENs will be disabled. The 
  1473. REGENAUTO setting is also saved as part of your drawing file, so you only need 
  1474. to execute it once per drawing. You may even want to set REGENAUTO off in 
  1475. your ACAD.DWG drawing template so that all your drawings are created with 
  1476. REGENAUTO set off.
  1477.  
  1478. Third-Party Software
  1479.  
  1480. If you are having trouble with TurboDLDClassic and third-party AutoCAD 
  1481. applications, be sure that the third-party application supports ADI 4.2. In order to 
  1482. use the ADI 4.2 specification, third-party applications require new T-Drivers and 
  1483. therefore must be revised. If an application does not specifically say that it is ADI 
  1484. 4.2 compatible, it probably is not. Check with the manufacturer to be sure.
  1485.  
  1486. If your third-party application is ADI 4.2 compatible and you are having trouble 
  1487. using TurboDLDClassic, try running AutoCAD without the third-party application 
  1488. to try to isolate the problem. Also, try the third-party application with the SVADI 
  1489. driver shipped with AutoCAD, this will also help to isolate the source of the 
  1490. problem.
  1491.  
  1492. Also note that any third-party TSR that needs to access the display may not work 
  1493. properly when using AutoCAD with any advanced ADI display driver, especially 
  1494. if the TSR switches graphics modes. Most TSRs will not support the same 
  1495. graphics platforms as TurboDLDClassic and therefore, will not be able to 
  1496. accommodate mode switching back and forth.
  1497.  
  1498. Slow Scrolling
  1499.  
  1500. If you have configured for the graphics mode text window and are experiencing 
  1501. slow script file execution, it might be your graphics board. Some graphics boards 
  1502. do not handle graphics mode text scrolling very quickly. To test this, try 
  1503. configuring for the SINGLE screen option in the Basic Configuration sub-menu of 
  1504. the TurboDLDClassic Configuration menu.
  1505.  
  1506. Color Considerations
  1507.  
  1508. Switching Color Modes
  1509.  
  1510. When switching color modes, (i.e. from 16 to 256 or vice versa) the DLDCOLOR 
  1511. command should be run in order to reconfigure your color palette for the number 
  1512. of colors selected.
  1513.  
  1514. Changing to a Light Background
  1515.  
  1516. If you would like to switch from TurboDLDClassic's default black background to 
  1517. a white or light background, type 
  1518.  
  1519.     DLDCOLOR
  1520.  
  1521. at the Command prompt to start the CustomColors utility. Once there, press O for 
  1522. (O)bject and then move the highlight to the Background item and then press 
  1523. ENTER. Move the color highlight to the desired new background color and press 
  1524. ENTER. Next, move the highlight to the Cursor item and press ENTER. Move 
  1525. the color highlight to the desired new Cursor color and press ENTER. Press the 
  1526. ESC key and then S to (S)ave and E to (E)xit. You should now have a light 
  1527. background with a dark crosshair.
  1528.  
  1529. Corrupt TurboDLDClassic Data Files
  1530.  
  1531. If you are having problems configuring TurboDLDClassic, be sure that you are 
  1532. using either the original distribution diskettes or a faithful copy made with the 
  1533. DOS DISKCOPY command. We have at times received Tech calls where we 
  1534. could not trace a specific recurring problem which later turned out to be a bad 
  1535. duplicate disk. 
  1536.  
  1537. If everything appears to have installed correctly and you still can't seem to figure 
  1538. out what's happening, try deleting the DLDSETUP.DAT, DLXMENUS.DAT and 
  1539. DLXBUTTN.DAT files from your TurboDLDClassic sub-directory. You'll then 
  1540. have to reconfigure the driver from scratch.  We've seen some strange things 
  1541. happen when these files have become corrupted.
  1542.  
  1543. Configuring TurboDLD for Your Graphics Board
  1544.  
  1545. You may need to look for your graphics board by its video chip instead of its 
  1546. name. There are many graphics board manufacturers, some not so famous enough 
  1547. to be known by a brand name. In these cases, you must configure for your 
  1548. graphics board by its video chip type. Check your documentation, or if you 
  1549. already know it, use the Generic selection for your chip type.
  1550.  
  1551. Static BP in Panning Mode
  1552.  
  1553. When using the static Big Picture in panning mode, the drawing screen will 
  1554. continue to pan until you move the cursor out of the Big Picture viewport. The 
  1555. drawing screen will display the selected view correctly.
  1556.  
  1557. Pull-Downs and Crosshairs Leave Trash on the Screen
  1558.  
  1559.  
  1560.  
  1561.  
  1562. Chapter 8
  1563.  
  1564. Rendering With
  1565. TurboDLD
  1566. Classic
  1567. Since TurboDLDClassic is a combined, display and rendering, device driver, it 
  1568. can be used to generate high-resolution renderings with Autodesk's 3D Studio and 
  1569. AutoShade programs, as well as with AutoCAD R12's built-in AVE Render. 
  1570. Configuration for these programs basically involves selecting the proper Display 
  1571. and Rendering resolutions from the TurboDLDClassic configuration menu. The 
  1572. other driver configuration options, except for font selection options for 3D Studio, 
  1573. are ignored for rendering because a Display List, and its configuration parameters, 
  1574. is not used during the rendering process.
  1575.  
  1576. Autodesk
  1577. 3D Studio
  1578.  
  1579. Configuring 3D Studio requires three steps. First, you need to set the environment 
  1580. variables for 3D Studio by running the PANA3DS.BAT file that was copied into 
  1581. your TurboDLDClassic sub-directory. Next, you must edit the 3DS.SET file 
  1582. located in your 3DS directory. 
  1583.  
  1584. The following three lines of the 3DS.SET file tell 3D Studio which driver to use 
  1585. for the rendering screen, main screen and materials editor screen, respectively. 
  1586. Locate the lines that begin with:
  1587.  
  1588.     RENDER-DISPLAY
  1589.     MAIN-DISPLAY
  1590.     MATERIAL-DISPLAY
  1591.  
  1592. and change them to use the RCPADI driver, TurboDLD, as follows:
  1593.  
  1594.     RENDER-DISPLAY=RCPADI
  1595.     MAIN-DISPLAY=RCPADI
  1596.     MATERIAL-DISPLAY=RCPADI
  1597.  
  1598. Make sure to remove the ";" or any spaces that may be present at the beginning of 
  1599. the line.
  1600.  
  1601. Note that it is only necessary for the RENDER-DISPLAY line to be set to CPADI 
  1602. in order to render at high resolution. If you do not need a high resolution main 
  1603. display screen or if you will not be using the materials editor, you may keep
  1604. MAIN-DISPLAY and MATERIAL-DISPLAY set to their defaults.
  1605.  
  1606. For 3D Studio v3.x, use the Autodesk supplied utility to edit the 3DS.SET file. 
  1607. From your 3DS sub-directory, type: 
  1608.  
  1609.     3DS VIBCFG
  1610.  
  1611. to display the configuration screen. Use the TAB key to move the cursor among 
  1612. the available parameters. The ENTER key allows you to select an available 
  1613. driver. Change the RENDER-DISPLAY, MAIN-DISPLAY and MATERIAL-
  1614. DISPLAY fields to use RCPADI and then press SHIFT-TAB to move to OK. 
  1615. Press ENTER and save your changes. 
  1616.  
  1617. For 3D Studio versions 1, and 2, use any text editor to make the above changes.
  1618. For 3D Studio 1.x, there is no RENDER-DISPLAY line. The corresponding line is 
  1619. DEFAULT-DISPLAY and should be changed to read
  1620.  
  1621.     DEFAULT-DISPLAY="RCPADI"
  1622.  
  1623. The quotes around RCPADI must be used for this version of 3D Studio.
  1624. The MATERIAL-DISPLAY should only be configured for RCPADI when BOTH 
  1625. the Display AND Rendering Resolutions of TurboDLDClassic are configured for 
  1626. 256 color resolutions. An unpredictable Materials Editor screen will appear if 
  1627. anything other than 256 colors is selected. If you are unsure about the function of 
  1628. the Materials Editor screen, use the Materials Editor as VGA, you should not have 
  1629. any problems at all. Please note too, that the use of the Materials Editor will not 
  1630. give you any more colors to choose from, just higher resolution.
  1631. After saving 3DS.SET changes, the final steps in the configuration process 
  1632. configure TurboDLDClassic for use with 3D Studio.
  1633.  
  1634. Delete (or rename) the 3DADI.CFG file from your 3D Studio sub-directory by 
  1635. typing,
  1636.  
  1637.     DEL  3DADI.CFG
  1638.  
  1639. Deleting this file will cause 3D Studio to start in its reconfiguration mode. 
  1640. 3DADI.CFG will be recreated after 3D Studio has been reconfigured.
  1641. Start the 3D Studio reconfiguration by typing;
  1642.  
  1643.     3DS
  1644.  
  1645. During the 3D Studio start-up, you are prompted with a series of configuration 
  1646. questions. After each question is answered, TurboDLDClassic  will display either 
  1647. a Display Screen or a Rendering Screen Configuration menu, depending on 
  1648. whether the 3D Studio question references a display or a rendering option.
  1649.  
  1650. To configure the 3D Studio Main Display for your graphics board, from the 
  1651. Display Configuration menu, select a display graphics board and then a display 
  1652. resolution.
  1653.  
  1654. To configure 3D Studio for the Rendering and/or Materials screens, select a 
  1655. rendering graphics board (usually the same as the Display board) and a 
  1656. rendering resolution. (For detailed information on choosing graphics boards or 
  1657. display and rendering resolutions, See Chapter 3 - Installing and Configuring.) 
  1658. Because RCPADI device drivers, by definition, are combined Display and 
  1659. Rendering devices, during 3D Studio reconfiguration, you may be brought to the 
  1660. TurboDLDClassic
  1661.  
  1662. Configuration menu more than one time each. It is not necessary to select display 
  1663. and/or rendering resolutions a second time. Simply press the ENTER key to 
  1664. remove the help screen and then highlight Save and Exit to continue to the next 
  1665. question. Also, if FASTACAD.BAT is used instead of PANA3DS.BAT to define 
  1666. the AutoCAD operating environment, the TurboDLDClassic Configuration Menu 
  1667. will also appear for RDPADI and DSPADI devices if they are present.
  1668.  
  1669.  
  1670. Some 3D Studio Limitations
  1671.  
  1672.      
  1673. TurboDLDClassic only provides still rendering support for 3D Studio. This driver 
  1674. will not play back rendered FLI or FLC files at resolutions above the 320x200 
  1675. default of 3D Studio. 
  1676.  
  1677. If you have a VESA compatible graphics board you may be able to use the 
  1678. RCPVESA.EXP driver that comes with 3D Studio to display animations at high 
  1679. resolution. Refer to your 3D Studio Installation and Performance Guide for 
  1680. specific information.
  1681.  
  1682. Configuring AVE Render
  1683.  
  1684. AutoCAD 12's AVE Render uses TurboDLDClassic's rendering capabilities to 
  1685. render objects and drawings. If AVE Render has never been configured, when you 
  1686. select the AutoCAD render command, you are required to run through its 
  1687. configuration process. In this case, you are prompted through the following 
  1688. questions and/or menus.
  1689.  
  1690. 1.  Select a Rendering Display device. Since TurboDLDClassic is a combined 
  1691. display/rendering device, choose item 1, P386 ADI Combined 
  1692. Display/Rendering Driver from the available choices.
  1693.  
  1694. 2. Configure the Rendering Graphics Board and Resolution. Here the 
  1695. TurboDLDClassic configuration program will appear on the screen. Press 
  1696. the Return key to continue past the help screen and display the Rendering 
  1697. Configuration menu. Choose Select Graphics Board/Resolution to display 
  1698. graphics board and resolution menu selections. Select a rendering graphics 
  1699. board and then a rendering resolution.
  1700.  
  1701. 3. Select Render Mode. The next step is to select the rendering mode for 
  1702. TurboDLDClassic. Select either Render to Viewport or Render to Screen 
  1703. depending on how you wish to view your renderings. Note that in order to 
  1704. render to a viewport you must be using a Display resolution of more than 
  1705. 16 colors. Otherwise, AVE Render will not allow the render to viewport 
  1706. selection.
  1707.  
  1708. 4. Select Render Hard Copy Device. If you are using a rendering hard copy 
  1709. device select your device type from the list of choices. If you are not using a 
  1710. hard copy device, accept the default of NULL.
  1711.  
  1712. After configuring AVE Render, you will return to the drawing to render the 
  1713. current drawing.
  1714.  
  1715. If you have previously configured AVE Render for another driver, you will need 
  1716. to reconfigure. Type RCONFIG at the AutoCAD command prompt to manually 
  1717. invoke the Render Configuration Menu. Follow these steps to re-configure AVE 
  1718. Render.
  1719.  
  1720. 1. Select option 2, Configure Rendering Device to choose a new rendering 
  1721. driver. Answer YES to the "Select Different Rendering Device" question.
  1722.  
  1723. 2. Select option 1, P386 Combined Display/Rendering Driver to choose the 
  1724. type of driver being used.
  1725.  
  1726. 3. Configure the Rendering Graphics Board and Resolution. At this point, 
  1727. the TurboDLDClassic configuration program will appear on the screen. 
  1728. Press the Return key to continue past the help screen and display the 
  1729. Rendering Configuration menu. Choose Select Graphics 
  1730. Board/Resolution to display graphics board and resolution menu 
  1731. selections. Select a rendering graphics board and then a rendering 
  1732. resolution.
  1733.  
  1734. 4. Select Render Mode. The next step is to select the rendering mode for 
  1735. TurboDLDClassic. Select either Render to Viewport or Render to Screen 
  1736. depending on how you wish to view your renderings. Note that in order to 
  1737. render to a viewport you must be using a Display resolution of at least 256 
  1738. colors. Otherwise, AVE Render will not allow a render to viewport 
  1739. selection.
  1740.  
  1741. 5. Select Exit to the Drawing Editor from the Render Configuration menu 
  1742. and then type Y to keep the changes you've just made. Press the <F1> key 
  1743. to change to the graphics screen if necessary.
  1744.  
  1745. AutoShade 2.0
  1746. with RenderMan
  1747.  
  1748. To configure AutoShade v2.0 to use TurboDLDClassic, first run the 
  1749. FASTACAD.BAT file from your TurboDLDClassic sub-directory to set the 
  1750. AutoShade environment variables. Next, start AutoShade with SHADE /R, which 
  1751. will allow you to reconfigure AutoShade. For the display device, select P386 
  1752. Autodesk Device Interface display driver, and for the rendering display select 
  1753. the P386 Autodesk Device Interface rendering driver. If you are running the 
  1754. display and rendering screen on the same monitor (i.e. single monitor), make sure 
  1755. to tell AutoShade this. A single monitor approach will require a redraw of the 
  1756. display screen after a rendering screen.
  1757.  
  1758. Once the P386 ADI devices have been selected, the TurboDLDClassic configuration 
  1759. menu will be displayed. Follow the same installation steps that were used to select the 
  1760. graphics board and display and rendering resolutions for AutoCAD (see Chapter 3 - 
  1761. Installing and Configuring)
  1762.  
  1763.  
  1764. Appendix A - Support Information
  1765.  
  1766. Just the Fax, Ma'am
  1767.  
  1768. When possible, please send problem reports by fax, on-line message, or regular 
  1769. mail, including the information requested below.  
  1770.  
  1771. It is much easier and more productive for us to work with a page of information or 
  1772. an on-line message than it is to try and get the information from you during a 
  1773. voice phone call over a busy, noisy line.  Once we get your faxed request, we will 
  1774. call you or fax you back with an answer or with additional questions to learn more 
  1775. about the problem.
  1776.  
  1777. You may reach our Technical Support,  staff via fax, phone or mail at:
  1778.  
  1779.         OEM Name
  1780.         OEM Street                               
  1781.         OEM City/State
  1782.               OEM Phone - OEM Fax
  1783.                      OEM E-Mail
  1784.  
  1785.  
  1786. Please put the following information in a faxed request, or have this information 
  1787. ready for a phone request:
  1788.  
  1789. ∙    Your name, and the serial and version number of your copy of 
  1790.     TurboDLDClassic.
  1791.  
  1792. ∙    A list of what appears on the screen when you type "SET" at a DOS prompt.  
  1793.     (Or print out a screen shot and attach it to the fax).
  1794.  
  1795. ∙    Print-outs of your DLDSETUP.DAT and FASTACAD.BAT (R10/11) files.
  1796.  
  1797. ∙    Print-outs of your CONFIG.SYS, AUTOEXEC.BAT and any AutoCAD 
  1798.     start-up files.
  1799.  
  1800. ∙    A complete description of what the problem was and how many times, and 
  1801.     under which circumstances, it has occurred.  We can help you most efficiently 
  1802.     if you can recreate the problem with some consistency.
  1803.  
  1804. Many of the problems which may occur in setting up and using TurboDLDClassic 
  1805. are not really problems with the driver; instead, the problems occur in installing 
  1806. and getting access to additional memory for the driver.
  1807.  
  1808. Memory management programs, such as  QEMM, 386MAX, and EMM386, can 
  1809. cause memory conflicts on certain graphics platforms. In order to avoid these 
  1810. conflicts, it may be necessary to exclude certain memory regions from being used 
  1811. by the memory manager.
  1812.  
  1813. Also, if you are using a memory manager, avoid using any switches or utilities of 
  1814. the manager that may re-map upper memory blocks in order to load as many 
  1815. programs and TSR's "high" as possible (i.e. QEMM's "Stealth" mode or 
  1816. EMM386's HIGHSCAN). These features can make it difficult or impossible for 
  1817. TurboDLDClassic utility programs to locate certain video BIOS information. If 
  1818. you have memory problems, carefully check both the system documentation and 
  1819. the memory manager documentation before contacting Technical Support. System 
  1820. memory problems probably won't be solvable by us.
  1821.  
  1822. We aren't able to fix mis-set jumpers and incorrect configuration options over the 
  1823. phone. Please be sure that all hardware is installed and operating correctly before 
  1824. assuming that the driver is at fault. Carefully check your hardware documentation 
  1825. for the correct switch and jumper settings. 
  1826.  
  1827. Our support policy is to offer free phone and fax support to our users.  This policy 
  1828. is basically unlimited; we want our users to enjoy TurboDLDClassic and get the 
  1829. most out of it.  We are especially appreciative if you can help us identify a 
  1830. problem in using the driver or the documentation which we can fix in a subsequent 
  1831. upgrade, benefiting all customers.  We reserve the option to limit, withhold, or 
  1832. charge for support.  
  1833.  
  1834.  
  1835. This chapter alphabetically lists all TurboDLDClassic commands providing a 
  1836. quick reference. For complete information regarding the use of these commands, 
  1837. see Chapter 5 - TurboDLD Features.
  1838.  
  1839.  
  1840.  
  1841.  
  1842. Appendix B - TurboDLD Classic Commands
  1843.  
  1844. This chapter alphabetically lists all TurboDLDClassic commands providing a quick reference. For 
  1845. complete information regarding the use of these commands, see Chapter 5 - TurboDLD Features.
  1846. DLDBIGPIC        Calls up the Big Picture - use digitizer clicks to define an area and zoom into it. 
  1847. DLDBPDIM        Allows resizing and repositioning of the Big Picture.
  1848. DLDBPFREEZE        Toggles the Big Picture Zoom Mode between Float and Freeze modes.
  1849. DLDBPHILIGHT    Selects the highlight mode used to display the Big Picture.
  1850. DLDBPMODE        Toggles Big Picture between Zoom and Pan modes.
  1851. DLDBPREFRSH        Enables and Disables the Big Picture automatic update mode.
  1852. DLDBPSTATIC        Toggles the Big Picture to stay on the screen at all times.
  1853. DLDCOLOR        Invokes CustomColorsTM, Panacea's color configuration program.
  1854. DLDCOMPACT        Forces a manual clean-up of Display List memory returning any unused memory 
  1855.             back to the AutoCAD memory pool.
  1856. DLDDLIST        Toggles the display list function of TurboDLDClassic on and off.
  1857. DLDECHO        Toggles internal TurboDLDClassic command echoing at the AutoCAD command 
  1858.             line.
  1859. DLDHELP        Provides a list of TurboDLDClassic commands with one-line description of each, 
  1860.             within AutoCAD. It's recommended that you flip to the text screen to view the 
  1861.             output.
  1862. DLDREFRESH        Refreshes the Big Picture to reflect the most current changes to a drawing.
  1863. DLDSAVECFG        Saves the current TurboDLDClassic configuration for use in a later AutoCAD 
  1864.             drawing session. Retains the size, location and operating mode of the Big Picture.
  1865. DLDSTAT        Displays a listing of the current TurboDLDClassic parameters. A flip to the 
  1866.             graphics screen is recommended for this command. 
  1867. DLDUSAGE        Gives a to-the-byte breakdown of how memory is being used for display list 
  1868.             processing.
  1869. DLDVER        Displays the TurboDLDClassic version, serial number and registered user's name 
  1870.             at the AutoCAD command line.
  1871. DLDZMVMAX        Performs a REGEN-less Zoom ALL. This function is designed primarily for 
  1872.             AutoCAD Release 10/386 which does not have this capability built-in.
  1873. PD, ZD, ZW        PD - Pan Dynamic, ZD - Zoom Dynamic and ZW - Zoom Window are included in 
  1874.             TurboDLDClassic for backwards compatibility with MACH-12. These commands 
  1875.             will invoke the Big Picture.
  1876. ZI, ZO            ZI - Zoom In and ZO - Zoom Out will zoom the current viewport in or out 
  1877.             incrementally.
  1878.  
  1879.  
  1880. This Appendix describes the major program changes in this version compared to 
  1881. earlier versions of TurboDLD and MACH-12.
  1882.  
  1883.  
  1884.  
  1885.  
  1886.  
  1887. Appendix C - Changes From Previous Versions
  1888.  
  1889. This Appendix describes the major program changes in this version compared to 
  1890. earlier versions of TurboDLD and MACH-12.
  1891.  
  1892. Changes From TurboDLD v1.0
  1893.  
  1894. BP Cache
  1895.  
  1896. The memory cache for TurboDLD commands has been removed. A separate cache 
  1897. is no longer necessary due to the optimization of the driver's Display List 
  1898. performance. The effect of the BP Cache is now achieved internally, for all 
  1899. graphics platforms. This affects the BP Cache command DLDBPCACHE and the 
  1900. Configuration menu option to enable BP Cache.
  1901.  
  1902. Fast/Incremental REGEN
  1903.  
  1904. The Fast/Incremental REGEN mode option has also been removed from 
  1905. TurboDLD. TurboDLD v2.0 now offers a fast, incremental REGEN eliminating 
  1906. the need for a toggle command.
  1907.  
  1908.  
  1909.  Changes From MACH-12
  1910.  
  1911.  
  1912. During the integration of MACH-12 and TurboDLD, we found that various 
  1913. commands were duplicated. Because of this overlap, it was necessary to combine 
  1914. commands where it was possible and eliminate them where it was not. The 
  1915. following have been removed or are different from earlier MACH-12 versions.
  1916.  
  1917.     ALLON
  1918.     All Color Toggle commands
  1919.     CA - Cancel
  1920.     CCP - Continuous Center Pan
  1921.     RD - Quick Redraw 
  1922.     FS - Fill Enable/Disable
  1923.     SCP - Single Center Pan
  1924.     ZA - Zoom All
  1925.     ZP - Zoom Previous    
  1926.     ZT - Zoom Tiniest
  1927.  
  1928. The ZP and ZA commands are not processed by TurboDLDClassic. The driver 
  1929. simply passes these instructions on to AutoCAD as corresponding ZOOM All and 
  1930. ZOOM Previous AutoCAD commands. Using either of these two commands may 
  1931. cause an AutoCAD REGEN, unlike MACH-12 which did not. If you wish to 
  1932. obtain a REGENless zoom all or zoom previous, use the bird's eye to do the zoom.
  1933.  
  1934.  
  1935. Anti-Aliasing
  1936.  
  1937. Because only a limited number of graphics boards (those with the Edsun CEG 
  1938. RAMDAC in 256-color modes and Sierra HiColor RAMDAC in 32k-color 
  1939. modes) support anti-aliasing, TurboDLDClassic does not include this MACH-12 
  1940. feature. We have chosen to offer speed instead of a limited, less useful feature. 
  1941. The anti-aliasing commands
  1942.  
  1943.     AP - Anti-Aliasing On
  1944.     AO - Anti-Aliasing On
  1945.     AF - Anti-Aliasing Off
  1946.     AS - Enable Split Screen Anti-Aliasing
  1947.  
  1948. are no longer available.
  1949.  
  1950. Display-List (DL) Compression
  1951.  
  1952. Is now done automatically, internally, by TurboDLDClassic as needed. 
  1953. Bird's Eye redraw ratio
  1954. TurboDLDClassic's DLDBPREFRSH command functions the same as this 
  1955. MACH-12 configuration setting. The difference however, is that the MACH-12 
  1956. command was configurable. DLDBPREFRSH is not, it is either enabled or 
  1957. disabled.
  1958.  
  1959. Flip Screen Save
  1960.  
  1961. This feature is no longer necessary and has been removed.
  1962. Set Custom Command Names
  1963. command names cannot be changed through TurboDLDClassic  or the driver 
  1964. configuration utility. If you wish to change, or Alias, command names, you may 
  1965. do so by editing the ACAD.PGP file in your AutoCAD SUPPORT sub-directory.
  1966.  
  1967. Set Command Names Sent to Foreign AutoCAD
  1968.  
  1969. This MACH-12 setting is no longer necessary. TurboDLDClassic supports 
  1970. English versions of AutoCAD. For use with foreign AutoCAD versions, 
  1971. TurboDLDClassic supports .BDF fonts (supplied by Autodesk) for menus and 
  1972. pull-downs. This allows support for foreign versions of AutoCAD via font 
  1973. selection.
  1974.  
  1975.  
  1976.  
  1977.  
  1978.  
  1979.