home *** CD-ROM | disk | FTP | other *** search
/ Network Support Encyclopedia 9 / novell-nsepro-1992-vol09.iso / download / tb274.txt < prev    next >
Text File  |  1992-03-16  |  3KB  |  62 lines

  1.                              TECHNICAL BULLETIN
  2.                                Bulletin 1-274
  3.  
  4. Date:  September 10, 1990
  5.  
  6. Patches and Enhancements Relating to IBM PS/2 Hardware
  7.  
  8.      Several NetWare patches and enhancements have been released on NetWire
  9.      relating to IBM PS/2 hardware.  The following list identifies the
  10.      problem area, describes the patch and/or enhancement, and provides, in
  11.      parentheses, the filename on NetWire to download.
  12.  
  13.      PS/2 SCSI driver.  IBMSCSI.OBJ (dated 7-31-90) supports both caching
  14.      and noncaching PS/2 SCSI controllers.  This driver is for Advanced and
  15.      SFT NetWare 286 v2.15 Rev. C.  (PS2286.ZIP)
  16.  
  17.      PS/2 SCSI driver for ELS II.  This archive file includes several
  18.      operating system and utility files that have the PS/2 SCSI driver
  19.      linked in.  IBMSCSI.OBJ v1.02 (dated 7-31-90) supports both caching
  20.      and noncaching PS/2 SCSI controllers.  This driver is for ELS NetWare
  21.      Level II v2.15 Rev. C.  (ESCI.ZIP)
  22.  
  23.      32-bit memory board and cold boot loader.  The IBM PS/2 80386 memory
  24.      board software destroys the NetWare cold boot loader stored at Track 0
  25.      on a file server.  Previous to this patch, NetWare had to be booted
  26.      from diskette when using the memory board on a file server (see
  27.      Technical Bulletin 1-263).  This patch allows a NetWare operating
  28.      system to be cold-booted when the IBM memory board is installed in the
  29.      server.  This patch applies to Advanced and SFT NetWare 286 v2.15 Rev
  30.      C. (IBMMEM.ZIP)
  31.  
  32.      Note:    This patch is implemented using the patch applicator ZAPOBJ. 
  33.                However, this patch cannot be used in conjunction with other
  34.                patches applied with ZAPOBJ. 
  35.  
  36.      UPS monitoring on Model 70.  This patch modifies the NetWare operating
  37.      system to allow IBM PS/2 Model 70 computers with Type II keyboard
  38.      controllers to work properly with a UPS.  This patch applies to
  39.      Dedicated versions of Advanced, SFT, TTS, and ELS Level II NetWare
  40.      v2.15 Rev C. (UPSM70.ZIP)
  41.  
  42.      Note:    This patch cannot be implemented on the same system as the 
  43.               80386 PS/2 memory board patch.  (IBMMEM.ZIP)
  44.  
  45.      Model 30-286 driver.  This file includes fixes to the problem of
  46.      running NetWare on PS/2 Model 30-286 machines on Seagate drives. 
  47.      These drives operate somewhat differently from other drives shipped
  48.      with the machine.  The result of these differences is the error
  49.      message "Abend: Unable to reset PS/2 internal disk controller".  This
  50.      message, or a similar disk-access message, is displayed whenever the
  51.      disk is accessed by the operating system or utilities.  These patches
  52.      apply to the PS/2 Model 30-286 driver for ELS I v2.12, ELS II v2.15,
  53.      and Advanced and SFT NetWare 286 v2.15.  (M30PAT.ZIP)
  54.  
  55.      Model 70 A21 anomaly.  Some problems have arisen running NetWare on a
  56.      Model 70 A21 with the 121 Mb ESDI drive.  Intermittent errors and
  57.      server "hangs" have been experienced primarily with ARCnet NICs, but
  58.      sometimes with other topologies.  The problems stem from a
  59.      controller-setting routine that is not given enough time to perform
  60.      its function.  This problem can be avoided by using the Reference
  61.      diskette to set the Preempt parameter to "Disabled."
  62.