  1. February 1, 1991 
  2.  
  3.                   ACCESS SERVER and MODEMS 
  4.  
  5. Access Server supports asynchronous transmission speeds up to 19.2 Kbps 
  6. using dial-up modems such as the Hayes Smartmodem and modems with error 
  7. correction, data compression and/or V.32 capabilities.  A list of certified
  8. and recommended modems is included in this document.  Error correcting 
  9. modems are strongly recommended. 
  10.  
  11. For the best Access Server/modem relationship it is recommended that you 
  12. have the most recent version of Access Server and the most up to date PTF 
  13. (at the moment version 1.01 and PTF 238) 
  14.  
  15. The Access Server and ONLAN menus provide a list of modems which have been
  16. tested with Access Server and for which scripts have been written.  It can
  17. be very difficult (and sometimes impossible) to successfully use a modem 
  18. which is not specifically listed. 
  19.  
  20. 1. Access Server currently supports the following modems: 
  21.          Version 1.01 as shipped:Version 1.01 of Access Server, contains a
  22.           few modems not included with version 1.0.  ONLAN/PC was not
  23.           updated.  In order to update ONLAN/PC, copy the NASMODEM.CNF file
  24.           from Access Server Version 1.01 diskette to the ONLAN/PC diskette
  25.           and rename the file ONLANMDM.CNF.  
  26.                   Acer Modem 2424                      
  27.                   Anchor Signalman Lightning 24 
  28.                   AT&T 4000 and 4024 
  29.                   ATI 2400etc (Basic mode) and Error Correct Mode 
  30.                   CDS 296 Trellis 
  31.                   Codex 2234 
  32.                   Codex 2264 
  33.                   EasyData 
  34.                   Everex Evercom 24E 
  35.                   Datatronics Discovery 1200C, 1200P and 2400E 
  36.                   Fastcomm FDX Series 
  37.                   Hayes Smartmodem 300, Smartmodem 1200, Smartmodem 2400 
  38.                   Hayes V-series 2400 and V-series 9600   NOT the Ultra
  39.                   Hayes V.32 
  40.                   INCOMM TURBO 4800 
  41.                   Leading Edge Model "L" 1200                              
  42.                   Maxum Super Modem 2400                                 
  43.                   Microcom AX/1200-2400 Series    
  44.                   Microcom AX/9612-9624 Series    
  45.                   Microcom QX/12k and QX/V.32    
  46.                   Migent Pocket Modem    
  47.                   MultiTech 1200, 224, 224EH and 224EC    
  48.                   MultiTech V32 and 696    
  49.                   Penril Alliance V.32 and Datalink 2400    
  50.                   POPCOM X100    
  51.                   Practical Peripherals 1200 and 2400    
  52.                   Prometheus PROMODEM 1200    
  53.                   Rockwell RG 2400 PC Modem    
  54.                   Telebit T2500 and Trailblazer    
  55.                   UDS FasTalk 2400 and V.32    
  56.                   US Robotics Courier 2400 and 2400e    
  57.                   US Robotics Courier HST and Courier V.32    
  58.                   Ven-Tel 9600 Plus/9600 Plus II    
  59.                   Ven-Tel Pathfinder    
  60.  
  61. 2. Provided by PTF 238 
  62.           New Modem Strings have been added to ONLAN.CNF/ONLANMDM.CNF and
  63.           NASMODEM.CNF adding support for:  
  64.                   Codex 2234 and 2264 
  65.                   Hayes Smartmodem 9600 v.32 
  66.                   Hayes V-Series 2400 
  67.                   Intel 9600 ex  
  68.                   Microcom QX/4232 HS 
  69.                   NEC DSP 9630 and N9631 
  70.                   Penril Alliance v.32  
  71.                   Practical Peripherals 2400sa MNP 
  72.                   US Robotics Courier 2400e & 9600  
  73.                   Ven-Tel 9600 plus/9600 plus II  
  74.  
  75. V.42 
  76. At the present time V.42 and V.42bis capability is not specifically 
  77. supported.  However, it is often possible to get such modems to work with 
  78. Access Server if the V.42 feature is turned off. 
  79.  
  80. V.32 and MNP 
  81. US Robotics V.32 and MNP modems work properly with Access Server.  Other 
  82. "High End" modems with features such as V.32 and MNP which may work with
  83. Access Server tend to switch to such "feature" settings when communicating
  84. with exact duplicates of themselves and then can not communicate/connect
  85. with other modems unless manually reset. 
  86.  
  87. "HAYES COMPATIBLE" 
  88. Both Access Server and ONLAN provide the user with the choice of "Hayes 
  89. Compatible".  This provides only a 1200 BPS connection and is not 
  90. recommended as a choice unless all other options have been tried. 
  91. At speeds above 2400 bps the term "Hayes Compatible" has little meaning.  
  92.    
  93. MULTIPLEXERS   
  94. Certain AT&T, MultiTech, and Racal-Vadic MUXs have been certified.  Set the
  95.  
  96. MUX configuration to control carrier with DTR.  If using a MUX configure 
  97. Access Server for "Direct Connect" and for a specific baud rate (not AUTO 
  98. BAUD). 
  99.  
  100. DIRECT CONNECT 
  101. In addition PCs and/or ASCII terminals can be directly connected to the
  102. Access Server through a RS-232 null modem cable.  Distances greater than
  103. the RS232 specification of 50' require a modem or line driver.  Configure