home *** CD-ROM | disk | FTP | other *** search
/ TopWare 18: Liquid / Image.iso / liquid / top2075 / gepackt.exe / README.DOC < prev    next >
Encoding:
Text File  |  1992-03-30  |  4.9 KB  |  136 lines

  1. README.DOC
  2.  
  3. Recognita Plus 1.2.B34
  4.  
  5. Revision 30. March, 1992
  6.  
  7. Re: Manual
  8.  
  9. In the manuals (Rev. P1.2/IEW/05.91 and Rev. P1.2/IED/05.91)
  10.  
  11.       - Chapter  1, page  1-3, the  first sentence  should be as follows:
  12.         "...Excel 2.1, Lotus 1-2-3 1A, 2.0 and MS Word for Windows) and 5
  13.         more scanners."
  14.  
  15.       - Appendix A (Specifications), page A-2:
  16.         The PCX image file format is added to the accepted Image File
  17.         Formats.
  18.  
  19. Re: Languages and Output Character Sets
  20.     Chapter 5, Reference, in the DOS manual
  21.     Chapter 6, Advanced Features, in the Windows manual
  22.  
  23.         Now all the character sets are loaded automatically, you don't need
  24.         to load them through RECSETUP.
  25.  
  26.  
  27. Re: Memory Requirements, DOS environment
  28.  
  29.         Recognita Plus  uses the  High Memory  Area (HMA)  if an XMS driver
  30.         such  as  HIMEM.SYS  is  installed  in  CONFIG.SYS.   This   lowers
  31.         Recognita's installation  need for  conventional memory.   Although
  32.         about  240  KBytes  are  still  needed  during  recognition,  using
  33.         HIMEM.SYS will leave about 60 KBytes more memory for other resident
  34.         applications.
  35.  
  36.         Recognita  Plus  makes  better  use  of  HMA  than  MS-DOS 5.0 with
  37.         "DOS=high" enabled in CONFIG.SYS  therefore it is suggested  not to
  38.         enable this swith.
  39.  
  40.         Recognita Plus can use any Upper Memory Blocks (UMBs) found in your
  41.         machine to store runtime data there, so it is suggested that you
  42.         install an expanded memory manager (like EMM386 in DOS 5.0, or
  43.         QEMM-386 or 386Max or others) to create UMBs.
  44.  
  45.         If you encounter any problems you may disable these features by the
  46.         DOS'  environment  variable  MEMDISABLE  (see  your  Recognita Plus
  47.         User's Guide):
  48.  
  49.                 SET MEMDISABLE=HMA
  50.         or
  51.                 SET MEMDISABLE=UMB
  52.  
  53.         or both:
  54.  
  55.                 SET MEMDISABLE=HMA,UMB
  56.  
  57.  
  58. Re: Scanners supported by Recognita Plus:
  59.  
  60.         The Mitsubishi  MH216CG+MH01FC scanner  works under  MS Windows 3.0
  61.         standard  and  enhanced  modes  as  well  as under DOS. The default
  62.         scanmethod for standard mode is FAST, for enhanced mode is  NORMAL.
  63.         (In FAST method  the scanner reads  the whole page  in one step  if
  64.         your machine contains more than approx. 2 Mbytes of memory while in
  65.         NORMAL method it will stop 4 or 5 times.) In NORMAL method the  400
  66.         dpi resolution is disabled.
  67.  
  68.         If your machine employs a fast  386 processor running at 25 MHz  or
  69.         more you may try to set FAST method even in enhanced mode with  the
  70.         environment variable SCANMETHOD as described in your manual:
  71.  
  72.                 SET SCANMETHOD=FAST
  73.  
  74.         If you encounter any problems in FAST method (noisy or broken pixel
  75.         lines) change back to NORMAL method.
  76.  
  77.         In very rare  situations (too slow  386 machine) Enhanced  Mode may
  78.         give difficulties in NORMAL method, too. In this case start Windows
  79.         in Standard Mode (win/s).
  80.  
  81.  
  82. New scanners supported:
  83.  
  84. Microtek ScanMaker 600G     The description of MSF-300G is fully applicable.
  85.  
  86. Microtek ScanMaker 600Z     The description of MSF-300Z is fully applicable.
  87.  
  88. Microtek ScanMaker 800G     The description of MSF-400G is fully applicable,
  89.  
  90.       For all of the ScanMaker scanners add the following line to the
  91.       CONFIG.SYS file:
  92.       device=<path>MSCAN.SYS
  93.  
  94. Sharp JX-600                Flat-bed, colour, 300, 400 dpi resolution,
  95.                             ADF is not supported, brightness can be set
  96.                             between 32-255, default is 128
  97.                             interface card: GPIB-PCIIA
  98.                             PS/2 is not supported
  99.  
  100.    All Sharp scanners (incl. the earlier types) are supported under MS
  101.    Windows 3.0 386 Enhanced Mode only from sw packet version NI-488.2
  102.    on interface card version GPIB-PCIIA rev B.
  103.  
  104.  
  105. Umax UC300, UC630,          Flat-bed, colour, 300 dpi resolution,
  106.                             ADF supported,
  107.                             brightness between 1-101, default is 51,
  108.                             interface card: GSII, PS/2 supported (with
  109.                             interface card GSII-PS/2)
  110.                             Although they are colour scanners, Recognita
  111.                             uses them only in gray scale.
  112.  
  113. Umax UG630                  The description of UG80 is fully applicable.
  114.  
  115.  
  116. For further information please contact us:
  117.  
  118.  
  119.            SZKI Recognita Corp.
  120.           Customer Support Dept.
  121.          Budapest, Iskola u. 16.
  122.          H-1011, Hungary, Europe
  123. Phone: (361) 201-84-52 Fax: (361) 201-76-07
  124.               Tx: 22-5381
  125.  
  126.                   or
  127.  
  128.        Recognita Corp. of America
  129.           1156 Aster Avenue
  130.          Sunnyvale, CA 94086
  131. Phone: 1-408-241-5772 Toll-free: 800 255-4 OCR
  132.           Fax: 1-408-241-6009
  133.  
  134.  
  135. End of README.DOC
  136.