home *** CD-ROM | disk | FTP | other *** search
/ Power-Programmierung / CD1.mdf / magazine / pcpursui / inpcp101 / tutorial.doc < prev   
Text File  |  1992-03-03  |  26KB  |  697 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.  
  11.                             I N C O M M  :  P C P D I A L 
  12.  
  13.  
  14.                                        TUTORIAL
  15.  
  16.  
  17.                                     Version 1.0.1
  18.  
  19.  
  20.                        The Ultimate PcPursuit Automated Dialer 
  21.  
  22.  
  23.            From the "In Command of PcPursuit..." line of software products 
  24.  
  25.  
  26.                                Developed and Published 
  27.                                           By
  28.                                FutureSoft Technologies
  29.                                      P.O. Box 822
  30.                                  Hartselle, AL 35640
  31.                                          USA
  32.                                     (205) 778-9561
  33.  
  34.  
  35.                        Program and Documentation Copyright 1992
  36.                                FutureSoft Technologies
  37.                                 All Rights Reserved. 
  38.  
  39.           No  parts of this document or accompanying software may be copied
  40.           in part or in whole, except as  provided in the License statement
  41.           included with this product.
  42.  
  43.           "In  Command  of  PcPursuit..."  is  a  trademark  of  FutureSoft
  44.           Technologies.  Other product and company names  are trademarks of
  45.           their respective owners.
  46.  
  47.  
  48.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  49.  
  50.  
  51.  
  52.           Lesson 1 : Using Manager
  53.           ------------------------
  54.  
  55.                Getting Started
  56.                ---------------
  57.                1.   Start  up Manager.   If you  cannot complete  the first
  58.                     step (a) due  to insufficient memory,  then just  start
  59.                     with step b.
  60.  
  61.                  a. Enter your host comm  program first (Telix,  Procomm+).
  62.                     Shell to DOS (consult your host comm's manual). 
  63.  
  64.                  b. From the DOS prompt, type ->  Manager
  65.                     and hit the enter key.
  66.  
  67.  
  68.                2.   At the  menu bar,  select  the (=)  Miscellaneous  menu
  69.                     choice.  This can be done by selecting it with the left
  70.                     mouse button,  or you  can  type Alt-spacebar  on  your
  71.                     keyboard.
  72.  
  73.  
  74.                3.   Select the submenu choice: "About".  This  is done with
  75.                     the  left mouse  button or you  can use  the keyboard's
  76.                     arrow keys to move  the highlight bar over "About"  and
  77.                     then press your enter key.
  78.  
  79.                     The  window  displayed   gives  you  information  about
  80.                     Manager.  Press "OK"  button on the window and  it will
  81.                     close.   Use the left  mouse button or  just press your
  82.                     enter key.
  83.  
  84.  
  85.  
  86.  
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.  
  94.  
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.           Copyright 1992, FutureSoft Technologies                    Page 2
  111.  
  112.  
  113.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  114.  
  115.  
  116.  
  117.                User Configuration
  118.                ------------------
  119.                1.   Select the "Configuration" choice from the menu bar.
  120.  
  121.                2.   Select the "SprintNet Configuration" submenu choice.
  122.  
  123.                3.   Enter your  SprintNet ID,  Password, and  Terminal Type
  124.                     into  the  appropriate data  entry  fields.   To  cycle
  125.                     between  fields you can use  the TAB key,  or your left
  126.                     mouse  button.  At each field,  type in the appropriate
  127.                     information, and then select the next data entry field.
  128.                     DO  NOT PRESS  ENTER  YET!   If  you press  enter,  the
  129.                     default  button is  pressed --  we don't  want that  to
  130.                     happen yet.
  131.  
  132.  
  133.                     Finish entering all of your SprintNet information.   If
  134.                     you are  unsure about  your  terminal type,  use  'D1'.
  135.                     After you have entered your information, you now  press
  136.                     your  enter key to select the "Accept" button.  You can
  137.                     also TAB  to  the  "Accept"  action  button  and  press
  138.                     enter,  or  you  can  press it  using  the  left  mouse
  139.                     button.
  140.  
  141.                4.   Select   the  "Communications   Configuration"  submenu
  142.                     choice.
  143.  
  144.                5.   Enter  the  appropriate  information   describing  your
  145.                     default  communications  setup.    First,   select  the
  146.                     correct comm port you are using.  Again, TAB key cycles
  147.                     between  data entry  fields, or  you can  use the  left
  148.                     mouse  button.  Within  data entry fields,  you can use
  149.                     the keyboard  arrow keys to change  between selections,
  150.                     or make  your selection  with  the left  mouse  button.
  151.                     Finish up by  selection your baud,  parity, stops,  and
  152.                     word size.   The suggested values  for these items  are
  153.                     2400,  N, 1,  and  8 respectively.   Lastly,  press the
  154.                     "Accept" button.
  155.  
  156.                6.   Save your configuration by  choosing the "Save" submenu
  157.                     choice.
  158.  
  159.  
  160.  
  161.  
  162.  
  163.  
  164.  
  165.  
  166.  
  167.  
  168.  
  169.  
  170.  
  171.  
  172.  
  173.  
  174.  
  175.           Copyright 1992, FutureSoft Technologies                    Page 3
  176.  
  177.  
  178.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  179.  
  180.  
  181.  
  182.                SprintNet Access Numbers
  183.                ------------------------
  184.                1.   From the menu bar, select "SprintNet Dialer".  
  185.  
  186.                2.   Select the "Open" submenu choice.   This will open  the
  187.                     SprintNet Dialer Dialog.
  188.  
  189.                3.   You  will see  two  targets in  this  dialer, with  the
  190.                     highlight bar over the first entry.   Select the "Edit"
  191.                     action button  from the button  panel at the  bottom of
  192.                     the  dialer dialog.  You can select this using the left
  193.                     mouse button or you can use the TAB key to cycle around
  194.                     to the "Edit" button.  If you go past the "Edit" button
  195.                     using  TAB, use shift-TAB  to cycle  in reverse.   Once
  196.                     "Edit" is  active using TABbing, press  enter to select
  197.                     it.
  198.  
  199.                4.   The target edit  dialog will  appear.   You will  enter
  200.                     information  in   the  same  manner  as   you  did  for
  201.                     SprintNet  configuration.    The  only  information you
  202.                     should  have to change is the "Target ID."  The "Target
  203.                     City"  must remain as a "$" -- this signals the dialers
  204.                     that  this  target  is  a  regular  target  and  not  a
  205.                     PcPursuit target.  Do NOT enter any username, password,
  206.                     or  script information,  as these  do not apply  to the
  207.                     SprintNet target.
  208.  
  209.                     The  first entry in the list is your 1200 bps SprintNet
  210.                     access  number, while the second entry is your 2400 bps
  211.                     access number.
  212.  
  213.                5.   After  entering the appropriate  information, press the
  214.                     "Save" action button to save the SprintNet Dialer  back
  215.                     to disk.
  216.  
  217.                6.   Close  the  dialer  dialog  by  pressing  the  "Cancel"
  218.                     button.
  219.  
  220.  
  221.  
  222.  
  223.  
  224.  
  225.  
  226.  
  227.  
  228.  
  229.  
  230.  
  231.  
  232.  
  233.  
  234.  
  235.  
  236.  
  237.  
  238.  
  239.  
  240.           Copyright 1992, FutureSoft Technologies                    Page 4
  241.  
  242.  
  243.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  244.  
  245.  
  246.  
  247.                Making Your Own Target Dialer
  248.                -----------------------------
  249.                1.   From the menu bar, select "Target Dialer".
  250.  
  251.                2.   Select  the "Open" submenu  choice.   This will  open a
  252.                     File Selection Dialog.
  253.  
  254.                3.   In the  file selection  dialog, you  will see  an entry
  255.                     called "InComPcP.icd." Select this dialer.  This can be
  256.                     done by  double-clicking on  it  using the  left  mouse
  257.                     button,  or you  can  use the  TAB  and arrow  keys  to
  258.                     highlight  it  and press  your  enter key  to  open the
  259.                     dialer.
  260.  
  261.                4.   The target dialer will open and present you with a list
  262.                     of around 670 PcPursuitable targets.  Obviously this is
  263.                     an enormous  amount, so lets  make a smaller  dialer to
  264.                     use  by copying some of  the entries.   You will notice
  265.                     that  some targets are already tagged  (they have a '+'
  266.                     beside  them).   If  you wish,  you  can tag  some more
  267.                     targets, or  untag targets that are  currently tagged. 
  268.                     This is done using the left mouse button to move the
  269.                     highlight bar  over  the item  to be  tagged, and  then
  270.                     pressing  the right  mouse button.   This is  also done
  271.                     using the  arrow keys  to move  the  highlight bar  and
  272.                     pressing the spacebar to toggle the item's tag.
  273.  
  274.                5.   Once the desired targets are tagged, go to the menu bar
  275.                     and select the "Target Dialer" choice once again.
  276.  
  277.                6.   Select the submenu choice "Copy Entries to Clipboard".
  278.  
  279.                7.   Select the "Cancel" action button on the target  dialer
  280.                     dialog  to close the dialer.   You will  probably get a
  281.                     pop-up  query box, asking you  if you wish  to save the
  282.                     changes you made to the dialer.  Press the "Yes" button
  283.                     on the pop-up box.
  284.  
  285.                8.   Open a new target  dialer.  Follow the first  few steps
  286.                     above to  open the File  Selection Dialog again.   This
  287.                     time instead  of selecting anything, type  in the name,
  288.                     "Tutorial.icd" and press your enter key.  This opens
  289.                     up a brand new dialer.
  290.  
  291.                9.   The dialer is empty  and needs some targets!   From the
  292.                     menu bar, select "Target Dialer" once again, and  under
  293.                     it's submenu,  choose  "Paste Entries  After  Current".
  294.                     This  will paste the entries  you copied from the other
  295.                     target dialer earlier, in step 6.
  296.  
  297.                10.  Press the  "Save" action button on the  dialer, to save
  298.                     your new target dialer.
  299.  
  300.                11.  You  are  done  with  this  part for  now,  select  the
  301.                     "Cancel" action button on the dialer.
  302.  
  303.  
  304.  
  305.           Copyright 1992, FutureSoft Technologies                    Page 5
  306.  
  307.  
  308.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  309.  
  310.  
  311.  
  312.                Opening a Terminal Window
  313.                -------------------------
  314.                1.   From the menu bar, select "Terminal".
  315.  
  316.                2.   Select "Open" from the submenu choices.
  317.  
  318.                3.   Select "Shrink" from  the submenu choices.   This  will
  319.                     give  the terminal a frame which allows you to move and
  320.                     resize the window.
  321.  
  322.                4.   Move  and resize the terminal window.  This can be done
  323.                     by  using the  left mouse  button and  clicking  in the
  324.                     lower  right corner  of  the window  to  resize it,  or
  325.                     clicking  on  the  title bar  to  move  it.   From  the
  326.                     keyboard, press Ctrl-F5  to activate the  window.   Now
  327.                     use the arrow keys  to move the window and  Shift-arrow
  328.                     keys to resize the window.
  329.  
  330.                5.   Select "Grow Maximum" from the submenu choices.
  331.  
  332.  
  333.  
  334.  
  335.  
  336.  
  337.  
  338.  
  339.  
  340.  
  341.  
  342.  
  343.  
  344.  
  345.  
  346.  
  347.  
  348.  
  349.  
  350.  
  351.  
  352.  
  353.  
  354.  
  355.  
  356.  
  357.  
  358.  
  359.  
  360.  
  361.  
  362.  
  363.  
  364.  
  365.  
  366.  
  367.  
  368.  
  369.  
  370.           Copyright 1992, FutureSoft Technologies                    Page 6
  371.  
  372.  
  373.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  374.  
  375.  
  376.  
  377.                Adding Targets
  378.                --------------
  379.                1.   Open  up that  target dialer  you just  created.   This
  380.                     time,  select the dialer  named "Tutorial.icd" from the
  381.                     list of choices in the File Selection Dialog.
  382.  
  383.                2.   In the  target  dialer,  press  the  "Add  New"  action
  384.                     button.   The new entry will appear LAST in the list of
  385.                     targets, and will  have some dummy  information in  it.
  386.                     You need to edit it.
  387.  
  388.                3.   Move the highlight  bar over the last entry by pressing
  389.                     Ctrl-PgDn.    Select the  "Edit"  action  button.   The
  390.                     Dialer Entry Edit Dialog will appear. Enter the
  391.                     following information:
  392.  
  393.                          Target Name : The Right Place BBS
  394.                          Target City : GAATL
  395.                          Target ID   : 476-2607
  396.  
  397.                     Leave  the other  fields blank  or with  whatever dummy
  398.                     data  is there.  We will fill in this information later
  399.                     in the tutorial.
  400.  
  401.                     Press the "Accept" button.
  402.  
  403.                4.   Tag the new entry,  by using the spacebar or  the right
  404.                     mouse button.   Select from the  menu, "Target Dialer",
  405.                     submenu "Cut Entries  to Clipboard".  You will  see the
  406.                     new  entry cut  from the  list of  targets.   Now, move
  407.                     the  highlight bar to the  top of the  list of targets.
  408.                     The  easiest way  to do  this is  to hit  Ctrl-PgUp, or
  409.                     click  the  left  mouse  button  at  the  top  of   the
  410.                     scrollbar.   Lastly, from the  "Target Dialer submenu",
  411.                     select "Paste Entries Before Current".  This will place
  412.                     the new entry at the first of the list.
  413.  
  414.                5.   Generate a command script from this dialer.  First, tag
  415.                     the first  entry in  the list,  "The Right Place  BBS."
  416.                     Once this  is tagged, select the  "Create Command File"
  417.                     submenu under the  "Dialer" menu selection.   The  File
  418.                     Selection Dialog  will appear again, and  this time you
  419.                     will enter the command script's name.  Type in the name
  420.                     "TRP.cmd"  for the  command script's  file name.   This
  421.                     will be used in Lesson 2 later.
  422.  
  423.                6.   Finally, save the updated dialer by pressing the "Save"
  424.                     action  button and  then press  the "Cancel"  button to
  425.                     close the dialer.
  426.  
  427.  
  428.  
  429.  
  430.  
  431.  
  432.  
  433.  
  434.  
  435.           Copyright 1992, FutureSoft Technologies                    Page 7
  436.  
  437.  
  438.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  439.  
  440.  
  441.  
  442.                Dialing SprintNet and Targets
  443.                -----------------------------
  444.                1.   From the menu bar, select "SprintNet Dialer".
  445.  
  446.                2.   From the submenu select "Dial".
  447.  
  448.                3.   The  "Dialing Status  Window" will  appear and  dialing
  449.                     will commence.   You  will see  the interaction  in the
  450.                     Terminal Window you opened earlier.  Manager will  dial
  451.                     your SprintNet access number and log you in.  Once this
  452.                     is  done you will receive an alarm and a pop-up message
  453.                     box  notifying   you  that  the  connection   has  been
  454.                     achieved.  The dialing status window will close and you
  455.                     can proceed to dial  your targets.  You can  cancel the
  456.                     dialer by pressing  the small close  icon in the  upper
  457.                     left  hand corner  of the  window using the  left mouse
  458.                     button.    Likewise  you  can  press  Alt-F3  from  the
  459.                     keyboard.
  460.  
  461.                4.   You  are now connected  to SprintNet, next  go dial The
  462.                     Right Place  BBS.   Open your  target dialer using  the
  463.                     Target Dialer submenu choice Open, and selecting
  464.                     "Tutorial.icd" from the File Selection Dialog.  Once it
  465.                     is  opened,  make sure  The  Right Place  BBS  entry is
  466.                     tagged, and tag it if it is not.  Now, press the "Dial"
  467.                     action  button.   This  will  open  the Dialing  Status
  468.                     Window and  show  you  the  progress  of  your  dialing
  469.                     attempt.   You will also  see all  of the  transactions
  470.                     between Manager and SprintNet in its effort to contact
  471.                     The Right Place BBS, displayed in the terminal window.
  472.  
  473.                5.   Sit back and watch or go and  grab a snack.  The BBS is
  474.                     probably fairly  busy, but you will  eventually get on.
  475.                     In the case that you do not get through in a reasonable
  476.                     amount of time,  you can  select a BBS  other than  The
  477.                     Right Place and try  that instead, or even  better, you
  478.                     can tag all the entries in your dialer and press "Dial"
  479.                     to connect to any one of them, whichever answers first.
  480.  
  481.                     The remainder  of the tutorial is  tailored towards the
  482.                     target  The  Right  Place.   If  you  have  contacted a
  483.                     different BBS, adjust as necessary.
  484.  
  485.  
  486.  
  487.  
  488.  
  489.  
  490.  
  491.  
  492.  
  493.  
  494.  
  495.  
  496.  
  497.  
  498.  
  499.  
  500.           Copyright 1992, FutureSoft Technologies                    Page 8
  501.  
  502.  
  503.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  504.  
  505.  
  506.  
  507.                6.   Once  connected to  The  Right Place,  you will  get an
  508.                     alarm and  pop-up notification.  After  you dismiss the
  509.                     pop-up, and the  dialing status window  is closed,  you
  510.                     have a choice of what to  do next.  You can continue to
  511.                     interact with The Right Place within Manager, using the
  512.                     Terminal Window that  is currently open.   Or, you  can
  513.                     exit manager  at this point, using Alt-X, and return to
  514.                     your host communications program.  If you exit Manager,
  515.                     at the DOS prompt,  type "Exit" to return to  your host
  516.                     communications  program, or  if it  is not  active yet,
  517.                     call up your host comm program.
  518.  
  519.                7.   Log into  The Right Place  as a new  user and read  all
  520.                     instructions  carefully.    Fill  out  the  appropriate
  521.                     questionaires and read  the appropriate bulletins.   If
  522.                     you do NOT follow these instructions as they are given,
  523.                     you will NOT be granted access, so read and follow them
  524.                     carefully.    Make sure  to  record  your username  and
  525.                     password  for  this BBS.   You  will  need it  for your
  526.                     records and also  for updating the target entry  in the
  527.                     target dialer later on in this tutorial.
  528.  
  529.                     The  Right Place BBS is  our main support  board.  Once
  530.                     you finish  your validation procedures here,  drop us a
  531.                     note and tell us what you think about InComm:PcPDial so
  532.                     far.   Our username is "Future Tech".  We'll be looking
  533.                     forward to your email.
  534.  
  535.                8.   Once you are done with the BBS, and say Goodbye to  it,
  536.                     you  will  be  returned  to the  SprintNet  connection.
  537.                     Whether you  are in  your host  comm program  or within
  538.                     Manager, you must disconnect from the city, (Atlanta in
  539.                     this case).
  540.  
  541.                     To do  so, you can type "@" and hit the return key, and
  542.                     then  type "D"  and  hit the  return  key.   This  will
  543.                     disconnect from the city.  If  it does not work, try it
  544.                     again.  If  you are  still in Manager,  you can  simply
  545.                     select "Disconnect City" submenu under "Terminal".
  546.  
  547.                9.   Now  you are at the  SprintNet command level.   Hang up
  548.                     your  connection  by  typing "HANG"  at  the  SprintNet
  549.                     prompt.   Don't forget  to  press return  after  typing
  550.                     "HANG."  The modem connection will be dropped.
  551.  
  552.                10.  You are  done with the Lesson.   Select "Miscellaneous"
  553.                     from  the menu bar, and select from its submenu, choice
  554.                     "Exit Manager".  Or you can simply type Alt-X to exit.
  555.  
  556.  
  557.  
  558.  
  559.  
  560.  
  561.  
  562.  
  563.  
  564.  
  565.           Copyright 1992, FutureSoft Technologies                    Page 9
  566.  
  567.  
  568.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  569.  
  570.  
  571.  
  572.           Lesson 2 : Complete Automation, Part I
  573.           --------------------------------------
  574.  
  575.                1.   Start  up Manager,  either from  within your  host comm
  576.                     program or straight from DOS.  Either way is fine.
  577.  
  578.                2.   Open your target dialer called Tutorial.icd.
  579.  
  580.                3.   Edit the first entry,  the one you added as  "The Right
  581.                     Place BBS."   Modify the  remaining fields you  did not
  582.                     modify last  time.   You will supply  the username  and
  583.                     password you used to log into The Right Place BBS.  For
  584.                     "Connect  Script"  you  will  enter  the  script   name
  585.                     "TRP"  with  a  file  extension  appropriate  for  your
  586.                     host communications  program.   For  this tutorial,  we
  587.                     assume you are using Telix.
  588.  
  589.                     For example, here are some common extensions:
  590.  
  591.                          .SLC  ->  Telix
  592.                          .ASP  ->  Procomm+
  593.                          .SCR  ->  Qmodem, Telemate, GT Power
  594.  
  595.                     Update the fields as follows:
  596.  
  597.                          BBS Username   : <your BBS username for TRP>
  598.                          BBS Password   : <your BBS password for TRP>
  599.                          Connect Script : TRP.SLC
  600.  
  601.                4.   Save the dialer, by pressing the "Save" button.
  602.  
  603.                5.   Exit Manager, type Alt-X.
  604.  
  605.                The purpose of the above steps was to supply the dialer with
  606.                the  BBS username  and password,  and also  the name  of the
  607.                connect  script.  This information is written to a file when
  608.                a  target  is   reached,  giving  the   host  comm   program
  609.                information on what was connected to and how to proceed.
  610.  
  611.  
  612.  
  613.  
  614.  
  615.  
  616.  
  617.  
  618.  
  619.  
  620.  
  621.  
  622.  
  623.  
  624.  
  625.  
  626.  
  627.  
  628.  
  629.  
  630.           Copyright 1992, FutureSoft Technologies                   Page 10
  631.  
  632.  
  633.                      InComm:PcPDial, Release 1.0.1, March 3, 1992
  634.  
  635.  
  636.  
  637.           Lesson 3 : Complete Automation, Part II
  638.           ---------------------------------------
  639.           The  rest of  this lesson  is  tailored for  using  Dialer in  an
  640.           automated fashion with Telix as the host communications program. 
  641.           Future  releases will  contain automation  scripts for  all major
  642.           communications programs.
  643.            
  644.                1.   Start up Telix.
  645.  
  646.                2.   Invoke  the  script named  "IPCP.SLC."    This is  done
  647.                     by performing the following sequence:
  648.  
  649.                     Type Alt-G, and at the prompt enter ->  IPCP
  650.  
  651.                3.   The script will start.  Select choice "2) Dialer"  from
  652.                     the  given  menu.   You  will  be  given  a listing  of
  653.                     available dialer  command files.  After  the listing is
  654.                     given, you will  be presented  with a  data entry  box,
  655.                     asking you  for the command file name to run.  Here you
  656.                     will enter ->  TRP.CMD.  
  657.  
  658.                4.   Sit back and watch.  The script will call up Dialer and
  659.                     set it on  its way.   Dialer will dial The  Right Place
  660.                     BBS  until a connection is achieved.  It will write out
  661.                     the target  information to  a file,  and  exit back  to
  662.                     Telix.   The script will  read in the  information from
  663.                     the file and  will proceed  to log you  into The  Right
  664.                     Place  BBS, automatically.    You will  be left  at The
  665.                     Right Place's main menu.
  666.  
  667.                     The automatic "logging in" is performed by the compiled
  668.                     script  called TRP.SLC,  which is  the script  name you
  669.                     entered  for the  target entry  for "The  Right Place".
  670.                     Check  out the TRP.SLT source script to see how this is
  671.                     implemented.   This  will give  you an  idea of  how to
  672.                     create your own target specific scripts.
  673.  
  674.                5.   You're all done with the tutorial.  Adapt these methods
  675.                     for dialing  your own set  of BBSs.   And most  of all,
  676.                     have fun!
  677.  
  678.  
  679.  
  680.  
  681.  
  682.  
  683.  
  684.  
  685.  
  686.  
  687.  
  688.  
  689.  
  690.  
  691.  
  692.  
  693.  
  694.  
  695.           Copyright 1992, FutureSoft Technologies                   Page 11
  696.  
  697.