- PEOPLE LIFTS
-
- NOTE ** Mengo Industries, Inc., pool access system.
- NOTE **
- NOTE ** This section is based on the products of Mengo
- Industries, Inc., which is located at:
- NOTE ** 4611 Green Bay Road
- NOTE ** Kenosha, WI 53144
- NOTE ** Tel: (414) 652-3070
- NOTE ** Fax: (414) 652-9910
- NOTE **
- NOTE ** Mengo Industries, Inc. manufactures the Safe-
- Lift(R) pool access system people lift, the most
- advanced access lift available. The system is
- approved by OSHA and certified by ETL Testing
- Laboratory. Safe-Lift satisfies ADA access
- requirements and qualifies as an IRS tax deduction
- for barrier removal.
- NOTE **
- NOTE ** SECTION 14410 - PEOPLE LIFTS, Copyright 1998, The
- Architect's Catalog, Inc.
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Select paragraphs below applicable to project.
-
- A. Permanently-anchored pool access people lifts.
-
- B. Movable pool access people lifts.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete sections below not relevant to this project;
- add others as required.
-
- A. Section 03300 - Cast-In-Place Concrete.
-
- B. Section 16100 - Wiring Methods.
-
- C. Section _____ - _________________________.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section; add others as required.
-
- A. NFPA 70 - National Electrical Code.
-
- B. UL - Underwriters Laboratories.
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Manufacturer's catalog data, detail
- sheets, installation instructions, and maintenance
- requirements.
-
- C. Shop Drawings: Prepared specifically for this project;
- show dimensions of people lifts and interface with
- adjacent construction.
-
- D. Operating and Maintenance Data: Operating and
- maintenance instructions, parts lists, and wiring
- diagrams.
-
- 1.5 DELIVERY, STORAGE, AND HANDLING
-
- A. Inspect equipment and materials upon delivery to assure
- that specified products have been received.
- NOTE ** Delete the following article if no warranties are
- required, or if work is covered under the terms of
- a general project warranty specified elsewhere.
- You may edit the article to obtain a warranty from
- the Contractor only, or to suit other project-
- specific criteria.
-
- 1.6 WARRANTY
-
- A. Manufacturer: Three-year warranty against defects in
- workmanship and materials under normal use and
- conditions.
-
- B. During warranty period, replace or repair defective parts
- without cost provided they are not caused by any of the
- following:
- 1. Damage.
- 2. Mishandling.
- 3. Tampering.
- 4. Unauthorized repair or adjustment.
- 5. Electrical re-wiring.
- 6. Improper line voltage.
- 7. Overloading.
- 8. Mechanical or electrical abuse.
- 9. Surges caused by lightning or other Acts of God.
- 10. Purchaser neglect.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: Mengo Industries, Inc., 4611
- Green Bay Road, Kenosha, WI 53144; ASD. Tel: (414) 652-
- 3070, Fax: (414) 652-9910.
-
- B. Requests for substitutions will be considered in
- accordance with provisions of Section 01600.
- NOTE ** Delete paragraph above or below; coordinate with
- Division 1 requirements.
-
- C. Substitutions: Not permitted.
-
- D. Provide all people lifts from a single manufacturer.
-
- 2.2 EQUIPMENT
- NOTE ** Select permanently-anchored or movable pool access
- people lifts from paragraphs below.
-
- A. Permanently-Anchored Pool Access People Lifts: Safe-
- Lift(R) Pool Access System, 500 pound (227 kg) capacity,
- requiring no water pressure or chains for support.
- 1. Major Moving Parts: Stainless steel.
- NOTE ** Select one of the following three subparagraphs.
- 2. Upright Chair: Polypropylene seat.
- 3. Wheelchair Platform.
- 4. Incline Stretcher.
- 5. Electrically-operated by means of 24-volt UL-listed
- waterproof motor, including safety brake, stepped
- down from simple 110-volt current.
- 6. Controller: Sealed, 6-volt, four-button.
- NOTE ** Select one subparagraph below.
- a. Armrest controls.
- b. Poolside attendant controls.
-
- B. Movable Pool Access People Lifts: Safe-Lift(R) Pool
- Access System, 500 pound (227 kg) capacity, requiring no
- water pressure or chains for support.
- 1. Major Moving Parts: Stainless steel.
- NOTE ** Select one of the following three subparagraphs.
- 2. Upright Chair: Polypropylene seat.
- 3. Wheelchair Platform.
- 4. Incline Stretcher.
- 5. Electrically-operated by means of 24-volt UL-listed
- waterproof motor, including safety brake, stepped
- down from simple 110-volt current.
- 6. Controller: Sealed, 6-volt, four-button.
- NOTE ** Select one subparagraph below.
- a. Armrest controls.
- b. Poolside attendant controls.
-
- 2.3 ACCESSORIES
-
- A. Anchor Bolts: Type 316 stainless steel, threaded, 3/8
- inch (9.5 mm) diameter by 5 inches (127 mm) long; include
- nuts and washers.
- 1. Quantity: 5 for each permanently-anchored unit.
- 2. Quantity: 8 for each movable unit.
- NOTE ** Delete one of the following two paragraphs or allow
- both to remain as installer's option for setting
- anchors. Consult local fastener company for
- assistance. Installed anchor bolts should have no
- less than 4,000 pounds (1,814 kg) tensile pull
- resistance per bolt.
-
- B. Inserts: ____________________________.
-
- C. Epoxy Capsules: ___________________________.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Before starting installation, inspect substrates, verify
- critical dimensions, and examine conditions under which
- work is to be installed.
-
- B. Do not proceed with installation until unsatisfactory
- conditions have been corrected in a manner acceptable to
- the installer.
-
- C. Beginning installation constitutes acceptance of existing
- conditions and responsibility for satisfactory
- performance.
-
- 3.2 INSTALLATION
-
- A. General: Comply with manufacturer's instructions and
- recommendations for work required during installation.
- 1. Comply with the National Electrical Code for
- electrical work required during installation.
- 2. Perform work with competent, skilled workers under
- the direct control and supervision of the installer's
- experienced foreman.
- 3. Coordinate installation with the work of other
- trades.
-
- B. Supply all setting templates and diagrams for placement.
-
- C. Install anchors and anchor bolts.
- 1. Drill 1/2 inch (12.7 mm) diameter by 4 inch (100 mm)
- deep anchor bolt holes into pool deck in accordance
- with template.
- 2. Clean holes thoroughly with shop vaccuum or blow out
- with compressed air.
- 3. Ensure that anchor holes are clean and dry until
- anchors are set.
- NOTE ** Delete two of the following three subparagraphs.
- 4. Set bolts using inserts.
- 5. Set bolts using epoxy capsules.
- 6. Set bolts using inserts or epoxy capsules.
- NOTE ** Select first paragraph below for permanently-
- anchored people lifts. Select the second paragraph
- below for movable lifts.
-
- D. After bolts are set or cured, lift machine and carefully
- set down over bolts without damaging or dislodging bolts.
-
- E. After anchors are set or cured, roll machine directly
- over anchors without damaging or dislodging anchors.
-
- F. If anchors or anchor bolts are damaged or dislodged,
- remove machine and re-set anchors or bolts.
-
- G. Level machine using leveling shims supplied with machine
- or additional stainless steel washers. Check with 4-foot
- hand level.
- NOTE ** Select first paragraph below for permanently-
- anchored people lifts. Select the second paragraph
- below for movable lifts.
-
- H. After machine is set and level, place washers over bolts,
- apply nuts, and tighten. Do not over-tighten.
-
- I. After machine is positioned and level, place bolts into
- anchors and tighten. Do not over-tighten.
-
- J. Install motors, operating controls, and all equipment and
- accessories to provide a quiet, smoothly operating
- installation, free from sway, oscillation or vibration.
-
- K. Lubricate operating parts as required by manufacturer.
-
- 3.3 FIELD QUALITY CONTROL
-
- A. Acceptance Testing: Upon completion of the installation
- and before permitting use of system, perform acceptance
- tests as required and recommended by code and governing
- authorities.
-
- B. Make necessary adjustments of operating devices and
- equipment to ensure smooth and accurate operation.
-
- 3.4 CLEANING
-
- A. Before final acceptance, clean surfaces in accordance
- with manufacturer's recommendations.
-
- B. At completion of installation, remove tools, equipment,
- and surplus materials from site. Clean work areas.
- Remove trash and debris.
-
-
- END OF SECTION
-