home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 10171gsp.txt < prev    next >
Encoding:
Text File  |  1998-06-10  |  16.9 KB  |  421 lines

  1.                          SECTION 10171
  2.  
  3.                SOLID PLASTIC TOILET COMPARTMENTS
  4. NOTE ** This section includes solid polymer plastic and
  5.         solid phenolic toilet compartments manufactured by
  6.         Global Steel Products, Inc., headquartered at the
  7.         following address:
  8. NOTE **     Global Steel Products, Inc.
  9. NOTE **     95 Marcus Blvd.
  10. NOTE **     Deer Park NY 11729-4595
  11. NOTE **     Telephone 516-586-3330
  12. NOTE **     FAX 516-586-3455
  13. NOTE **
  14. NOTE ** SECTION 10171 - SOLID PLASTIC TOILET COMPARTMENTS,
  15.         Copyright 1996, The Architect's Catalog, Inc.
  16.  
  17. PART 1  GENERAL
  18.  
  19. 1.1 SECTION INCLUDES
  20. NOTE ** Delete items below not required for project.
  21. NOTE **
  22. NOTE ** If more than one type of compartment is required,
  23.         indicate which type is used where, either on the
  24.         drawings or in the Schedule Article of this
  25.         section.
  26.  
  27.     A.  Solid-polymer plastic toilet compartments, consisting of:
  28.         1.  Floor-mounted overhead-braced toilet compartments.
  29.         2.  Floor-to-ceiling toilet compartments.
  30.         3.  Wall-mounted urinal screens.
  31.         4.  Floor-mounted overhead-braced shower compartments.
  32.         5.  Floor-mounted overhead-braced dressing compartments.
  33.         6.  Floor-to-ceiling dressing compartments.
  34.  
  35.     B.  Solid phenolic toilet compartments, consisting of:
  36.         1.  Floor-mounted overhead-braced toilet compartments.
  37.         2.  Floor-to-ceiling toilet compartments.
  38.         3.  Wall-mounted urinal screens.
  39.         4.  Floor-mounted overhead-braced shower compartments.
  40.         5.  Floor-mounted overhead-braced dressing compartments.
  41.         6.  Floor-to-ceiling dressing compartments.
  42.  
  43.     C.  Compartment installation hardware.
  44.  
  45.     D.  Compartment door hardware.
  46.  
  47. 1.2 RELATED SECTIONS
  48.  
  49.     A.  Section 10800 - Toilet, Bath, and Laundry Accessories.
  50.  
  51. 1.3 SUBMITTALS
  52.  
  53.     A.  Submit under provisions of Section 01300.
  54.  
  55.     B.  Product Data:  Manufacturer's printed literature
  56.         indicating typical panel, pilaster, door, hardware and
  57.         fastening.
  58.  
  59.     C.  Shop Drawings:  Submit six sets of the following:
  60.         1.  Dimensioned plans indicating layout of toilet
  61.             compartments.
  62.         2.  Dimensioned elevations indicating heights of doors,
  63.             pilasters, separation partitions, and other
  64.             components; indicate locations and sizes of openings
  65.             in compartment separation partitions for toilet and
  66.             bath accessories to be installed in partitions;
  67.             indicate floor and ceiling clearances.
  68.         3.  Details indicating anchoring components and methods
  69.             for project conditions; indicate components required
  70.             for installation, but not supplied by toilet
  71.             compartment manufacturer.
  72.  
  73.     D.  Samples:  Two manufacturer's color cards representing
  74.         manufacturer's full color palette.
  75.  
  76. 1.4 DELIVERY, STORAGE AND HANDLING
  77.  
  78.     A.  Store compartment components until installation in
  79.         unopened cartons laid flat, with adequate support to
  80.         ensure flatness and to prevent damage to prefinished
  81.         surfaces.
  82.  
  83. 1.5 ENVIRONMENTAL REQUIREMENTS
  84.  
  85.     A.  Do not deliver materials or begin construction activities
  86.         of this section until building is enclosed, with complete
  87.         protection from outside weather, and building temperature
  88.         maintained at a minimum of 60 degrees Fahrenheit.
  89.  
  90. 1.6 SEQUENCING
  91.  
  92.     A.  Obtain accessory manufacturer's installation instructions
  93.         and installation templates for toilet and bath
  94.         accessories to be installed in compartment separation
  95.         partitions; supply instructions and templates to
  96.         installer before beginning construction activities of
  97.         this Section.
  98.  
  99. PART 2  PRODUCTS
  100.  
  101. 2.1 MANUFACTURERS
  102.  
  103.     A.  Acceptable Manufacturer:  Global Steel Products, Inc.; 95
  104.         Marcus Blvd., Deer Park NY 11729-4595; telephone 516-586-
  105.         3330, FAX 516-586-3455.
  106. NOTE ** Delete one of the two paragraphs below; coordinate
  107.         with Division 1 requirements.
  108.  
  109.     B.  Substitutions:  Not permitted.
  110.  
  111.     C.  Requests for substitutions will be considered in
  112.         accordance with provisions of Section 01600.
  113.  
  114. 2.2 SOLID POLYMER PLASTIC TOILET COMPARTMENTS
  115. NOTE ** Delete one of the two following paragraphs;  the
  116.         first is for Embassy floor-mounted overhead-braced;
  117.         the second is for Floor-to-Ceiling.
  118.  
  119.     A.  Acceptable Product:  Embassy Solid Plastic Toilet
  120.         Compartments.
  121.  
  122.     B.  Acceptable Product:  Floor-to-Ceiling Solid Plastic
  123.         Toilet Compartments.
  124.  
  125.     C.  Panels:
  126.         1.  Nominal thickness:  1 inch, thickness tolerance plus
  127.             or minus 0.03 inch.
  128.         2.  Construction:  Single sheet solid-polymer plastic
  129.             material, formed from waterproof, non-absorbent, high
  130.             density polyethylene resins; mark-resistant self-
  131.             lubricating surface; edges finished smooth.
  132.  
  133.     D.  Pilasters:
  134.         1.  Nominal thickness:  1 inch, thickness tolerance plus
  135.             or minus 0.03 inch.
  136.         2.  Construction:  Single sheet solid-polymer plastic
  137.             material, formed from waterproof, non-absorbent, high
  138.             density polyethylene resins; mark-resistant self-
  139.             lubricating surface; edges finished smooth.
  140. NOTE ** Delete one of the two paragraphs below.  First
  141.         paragraph is for floor-mounted compartments; second
  142.         paragraph is for floor-to-ceiling compartments.
  143.         3.  Pilaster installation hardware preparation:  Two
  144.             holes, diameter to accept 3/8 inch threaded rod,
  145.             drilled into core at pilaster base end, parallel to
  146.             pilaster vertical axis, intersecting centerlines of
  147.             two holes, diameter to accept Plug-Loc(tm)
  148.             installation hardware, drilled through pilaster
  149.             perpendicular to pilaster face and 1 inch from
  150.             pilaster base end.
  151.         4.  Pilaster installation hardware preparation:  Two
  152.             holes each at top and bottom, diameter to accept 3/8
  153.             inch threaded rod, drilled into core parallel to
  154.             pilaster vertical axis, intersecting centerlines of
  155.             two holes, diameter to accept Plug-Loc(tm)
  156.             installation hardware, drilled through pilaster
  157.             perpendicular to pilaster face and 1 inch from
  158.             pilaster ends.
  159.  
  160.     E.  Doors:
  161.         1.  Nominal thickness:  1 inch, thickness tolerance plus
  162.             or minus 0.03 inch.
  163.         2.  Construction:  Single sheet solid-polymer plastic
  164.             material, formed from waterproof, non-absorbent, high
  165.             density polyethylene resins; mark-resistant self-
  166.             lubricating surface; edges finished smooth.
  167.         3.  Hinge preparation:  Prepare doors for heavy-duty
  168.             "bank vault" hinges.
  169.  
  170.     F.  Color:  Selected from manufacturer's full color palette.
  171.  
  172. 2.3 SOLID PHENOLIC TOILET COMPARTMENTS
  173. NOTE ** Delete one of the following two paragraphs; the
  174.         first is for Embassy floor-mounted overhead-braced;
  175.         the second is for Floor-to-Ceiling.
  176.  
  177.     A.  Acceptable Product:  Embassy Phenolic Toilet
  178.         Compartments.
  179.  
  180.     B.  Acceptable Product:  Floor-to-Ceiling Phenolic Toilet
  181.         Compartments.
  182.  
  183.     C.  Panels:
  184.         1.  Nominal thickness:  1/2 inch.
  185.         2.  Core:  Multiple layers phenolic resin impregnated
  186.             Kraft papers bonded under heat and pressure.
  187.         3.  Face sheets:  Decorative face papers, phenolic resin
  188.             impregnated, bonded under heat and pressure integral
  189.             with core.
  190.         4.  Edges:  Finished smooth.
  191.  
  192.     D.  Pilasters:
  193.         1.  Nominal thickness:  3/4 inches.
  194.         2.  Core:  Multiple layers phenolic resin impregnated
  195.             Kraft papers bonded under heat and pressure.
  196.         3.  Face sheets:  Decorative face papers, phenolic resin
  197.             impregnated, bonded under heat and pressure integral
  198.             with core.
  199.         4.  Edges:  Finished smooth.
  200. NOTE ** Delete one of the two following paragraphs; the
  201.         first is for Embassy floor-mounted overhead-braced;
  202.         the second is for Floor-to-Ceiling.
  203.         5.  Pilaster installation hardware preparation:  Two
  204.             holes, diameter to accept 3/8 inch threaded rod,
  205.             drilled into core at pilaster base end, parallel to
  206.             pilaster vertical axis, intersecting centerlines of
  207.             two holes, diameter to accept Plug-Loc(tm)
  208.             installation hardware, drilled through pilaster
  209.             perpendicular to pilaster face and 1 inch from
  210.             pilaster base end.
  211.         6.  Pilaster installation hardware preparation:  Two
  212.             holes each, diameter to accept 3/8 inch threaded rod,
  213.             drilled into core at pilaster ends, parallel to
  214.             pilaster vertical axis, intersecting centerlines of
  215.             two holes, diameter to accept Plug-Loc(tm)
  216.             installation hardware, drilled through pilaster
  217.             perpendicular to pilaster face and 1 inch from
  218.             pilaster ends.
  219.  
  220.     E.  Doors:
  221.         1.  Nominal thickness:  3/4 inches.
  222.         2.  Core:  Multiple layers phenolic resin impregnated
  223.             Kraft papers bonded under heat and pressure.
  224.         3.  Face sheets:  Decorative face papers, phenolic resin
  225.             impregnated, bonded under heat and pressure integral
  226.             with core.
  227.         4.  Edges:  Finished smooth.
  228.  
  229.     F.  Finish:  Selected from manufacturer's full color palette.
  230.  
  231. 2.4 ACCESSORIES
  232.  
  233.     A.  Pilaster Shoes:  Four-piece Type 304 stainless steel
  234.         assembly, No. 4 satin finish, hemmed top and bottom
  235.         edges.
  236. NOTE ** Delete one of the two paragraphs below.  The first
  237.         paragraph is for floor-mounted overhead-braced
  238.         compartments; the second is for floor-to-ceiling
  239.         compartments.
  240. NOTE **
  241. NOTE ** Floor-mounting requires a concrete floor for
  242.         adequate anchorage.
  243.  
  244.     B.  Pilaster Anchors:  Manufacturer's standard floor anchor
  245.         with leveling adjustment, concealed by pilaster shoe
  246.         after installation.
  247.  
  248.     C.  Pilaster Anchors:  Manufacturer's standard floor and
  249.         ceiling anchors with leveling adjustment, both concealed
  250.         by pilaster shoe after installation.
  251.  
  252. NOTE ** Delete paragraph below if overhead-braced
  253.         compartments are not required.
  254.  
  255.     D.  Head Rail:  Manufacturer's standard anodized aluminum
  256.         rail with anti-grip device.
  257. NOTE ** Delete one of the two following sets of paragraphs.
  258.         The first set is for polymer compartments only.
  259.         The second set is for phenolic compartments only.
  260.         Delete urinal screen brackets if urinal screens are
  261.         not required.
  262.  
  263.     E.  Brackets:  Heavy duty extruded anodized aluminum, three
  264.         brackets per connection.
  265.  
  266.     F.  Urinal Screen Brackets:  Manufacturer's standard full
  267.         height 38-inch-long heavy duty anodized extruded
  268.         aluminum, prepared for fastening hardware.
  269. NOTE ** The following set of brackets is for phenolic
  270.         compartments.
  271.  
  272.     G.  Brackets:  Die-cast No.304 stainless steel, No.4 satin
  273.         finish, with throughbolts and fasteners of same material
  274.         and finish with tamper-resistant heads.
  275.  
  276.     H.  Urinal Screen Brackets:  Manufacturer's standard die-cast
  277.         No.304 stainless steel, No.4 satin finish, prepared for
  278.         fastening hardware.
  279. NOTE ** The same type of door hardware is used on both
  280.         polymer and phenolic compartments.
  281.  
  282.     I.  Door Hardware:
  283.         1.  Top hinge:  Heavy-duty "bank vault" type, die-cast
  284.             aluminum alloy with brushed chrome-plated finish;
  285.             wrap-around pilaster and door mounting, through-
  286.             bolted.
  287.         2.  Bottom hinge:  Same as top hinge, with gravity-acting
  288.             cams.
  289.         3.  Latch:  Non-ferrous, satin chrome-plated, slide
  290.             latch, through-bolted.
  291.         4.  Strike and Keeper:  Permitting emergency access by
  292.             lifting the door until latch is clear of keeper;
  293.             satin chrome-plated finish; through-bolted.
  294.         5.  Coat Hook and Bumper:  Non-ferrous, chrome-plated,
  295.             with black rubber tip for door stop.
  296.         6.  Fastening Hardware:  Manufacturer's standard, No.304
  297.             stainless steel, No.4 satin finish, through-bolts and
  298.             attachment fasteners with tamper-resistant heads.
  299.  
  300.     J.  Toilet and Bath Accessories for Installation in
  301.         Compartment Separation Partitions:  Specified Section
  302.         10800.
  303.  
  304. PART 3  EXECUTION
  305.  
  306. 3.1 EXAMINATION
  307.  
  308.     A.  Verification of Conditions:
  309.         1.  Measure areas to receive compartments; verify area
  310.             dimensions are in accordance with shop drawings.
  311.         2.  Verify built-in framing, anchorage, bracing, and
  312.             plumbing fixtures are in correct location.
  313.  
  314.     B.  Installer's Examination:
  315.         1.  Have installer of this section examine conditions
  316.             under which construction activities of this section
  317.             are to be performed, then submit written notification
  318.             if such conditions are unacceptable.
  319.         2.  Transmit two copies of installer's report to
  320.             Architect within 24 hr of receipt.
  321.         3.  Beginning construction activities of this section
  322.             before unacceptable conditions have been corrected is
  323.             prohibited.
  324.         4.  Beginning construction activities of this section
  325.             indicates installer's acceptance of conditions.
  326.  
  327. 3.2 PREPARATION
  328.  
  329.     A.  Surface Preparation:
  330.         1.  Prepare openings in compartment separation partitions
  331.             for toilet and bath accessories to be installed in
  332.             partitions; marring of partition finish is
  333.             prohibited.
  334.         2.  Locate openings in accordance with shop drawings and
  335.             accessory manufacturer's installation instructions
  336.             and templates.
  337.  
  338. 3.3 INSTALLATION
  339.  
  340.     A.  Install compartments to specified tolerances in
  341.         accordance with shop drawings and manufacturer's printed
  342.         installation instructions.
  343.  
  344.     B.  Attach components to adjacent materials and to other
  345.         components using purpose-designed fastening devices.
  346. NOTE ** Delete one of two paragraphs below.
  347.  
  348.     C.  Adjust pilaster anchors for floor variations; conceal
  349.         anchors with pilaster shoes.
  350.  
  351.     D.  Adjust pilaster anchors for floor variations; conceal
  352.         anchors with lower pilaster shoes.  Support pilasters
  353.         from ceiling framing using two adjustable hanging studs;
  354.         for vertical adjustment to level; conceal ceiling
  355.         fasteners with upper pilaster shoes.
  356. NOTE ** The remaining provisions apply to all types of
  357.         compartments in this section.
  358.  
  359.     E.  Equip each compartment door with top and bottom hinges,
  360.         and door latch.
  361.  
  362.     F.  Install door strike keeper on pilasters in alignment with
  363.         door latch.
  364.  
  365.     G.  Equip each compartment door with one coat hook and
  366.         bumper.
  367.  
  368.     H.  Installation Tolerances:
  369.         1.  Maximum variation from plumb or level:  1/8 inch.
  370.         2.  Maximum displacement from indicated position:  1/8
  371.             inch.
  372.         3.  Clearance between wall surface and panels or
  373.             pilasters:  1-1/2 inch maximum.
  374.  
  375. 3.4 ADJUSTING
  376.  
  377.     A.  Adjust door hardware for uniform clearance between doors
  378.         and pilasters.
  379.  
  380.     B.  Adjust door hinges to attain free movement, to locate
  381.         in-swinging doors in partial open position when
  382.         unlatched; and to return out-swinging doors to closed
  383.         position.
  384.  
  385.     C.  Adjust door hardware to align door strike keeper on each
  386.         pilaster with door latch.
  387.  
  388. 3.5 PROTECTION OF INSTALLED PRODUCTS
  389.  
  390.     A.  Prevent damage to product finishes by subsequent
  391.         construction activities.
  392.  
  393.     B.  Replace components having damaged finish.
  394.  
  395.     C.  Remove factory protective coverings and clean finish
  396.         surfaces in accordance with manufacturer's instructions
  397.         before final inspection.
  398.  
  399. 3.6 SCHEDULE
  400. NOTE ** If more than one type of partition is required, or
  401.         more than one color or finish will be needed, a
  402.         schedule may help to identify the types and where
  403.         they are to be used.
  404.  
  405.     A.  Men's Locker Room No. ___:  Solid plastic toilet
  406.         compartments and urinal screens; compartments floor-to-
  407.         ceiling, urinal screens wall-mounted; compartment
  408.         separation partitions _______ color, pilasters _______
  409.         color.
  410.  
  411.     B.  Women's Locker Room No. ___:
  412.         1.  Solid plastic shower compartments; compartment
  413.             separation partitions _______ color, pilasters
  414.             _______ color.
  415.         2.  Phenolic dressing compartments, floor-mounted
  416.             overhead-braced; compartment separation partitions
  417.             _______ color, pilasters _______ color, doors _______
  418.             color.
  419.  
  420.                          END OF SECTION
  421.