home *** CD-ROM | disk | FTP | other *** search
Text File | 1998-06-10 | 65.9 KB | 1,471 lines |
- SECTION 08565
-
- VINYL (PVC) WINDOWS
- NOTE ** CertainTeed Corporation vinyl windows, patio doors,
- and specialty windows.
- NOTE **
- NOTE ** This section is based on fenestration products
- manufactured by CertainTeed Corporation, Vinyl
- Building Products Group, which is located at the
- following address:
- NOTE ** 750 E. Swedesford Road
- NOTE ** P.O. Box 860
- NOTE ** Valley Forge, PA 19482
- NOTE ** Tel: (800) 233-8990
- NOTE **
- NOTE ** CertainTeed Corporation's product lines of New
- Castle(tm) windows and doors, New Castle(tm) XT
- windows, and CertainTeed Garden Window offer a full
- selection of vinyl windows, patio doors, and
- specialty windows for installation in new
- residential and light commercial or institutional
- structures.
- NOTE **
- NOTE ** SECTION 08565 - VINYL (PVC) WINDOWS, Copyright
- 1997, The Architect's Catalog, Inc.
-
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Delete items below not required for project.
-
- A. Single Hung Windows.
-
- B. Double Hung Windows.
-
- C. Horizontal Gliding Windows.
-
- D. Casement Windows.
-
- E. Awning Windows.
-
- F. Bow Windows.
-
- G. Bay Windows.
-
- H. Operable Extended Arch Windows.
-
- I. Fixed Geometric Windows.
-
- J. Fixed Windows and Transoms.
-
- K. Patio Doors.
-
- L. Garden Windows.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- Section 05400 - Cold Formed Metal Framing.
-
- Section 06100 - Rough Carpentry.
-
- Section 09111 - Non-Load-Bearing Metal Framing.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section.
-
- A. AAMA 101 - Voluntary Specification for Aluminum and
- Polyvinyl Chloride (PVC) Prime Windows and Glass Doors.
-
- B. AAMA 303 - Voluntary Specification for Poly (Vinyl
- Chloride) (PVC) Exterior Profile Extrusions.
-
- C. AAMA 701 - Voluntary Specification for Pile Weatherstrip.
-
- D. AAMA 902 - Voluntary Specification for Sash Balances.
-
- E. ALI - Certification Program for Sealed Insulating Glass
- Units, SIG-901; Associated Laboratories, Inc.
-
- F. ASCE 7 - Minimum Design Loads for Buildings and other
- Structures.
-
- G. ASI B18-6-4 - Specification for Screw Fasteners; American
- Standards Institute.
-
- H. ASTM D 635 - Standard Test Method for Rate of Burning
- and/or Extent and Time of Burning of Self-Supporting
- Plastics in a Horizontal Position.
-
- I. ASTM D 1929 - Standard Test Method for Ignition
- Properties of Plastics.
-
- J. ASTM D 4726 - Standard Specification for White Rigid
- PolyVinyl Chloride (PVC) Exterior Profile Extrusions Used
- for Assembled Windows and Doors.
-
- K. ASTM E 774 - Standard Specification for Sealed Insulating
- Glass Units.
-
- L. CAWM 301 - Forced Entry Testing; California Association
- of Window Manufacturers.
-
- M. IGCC - Classification of Insulating Glass Units;
- Insulating Glass Certification Council.
-
- N. NFRC 100 (5M) - Thermal Properties; National Fenestration
- Rating Council.
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Provide manufacturer's standard details
- and catalog data demonstrating compliance with referenced
- standards; include installation instructions and storage
- requirements.
-
- C. Shop Drawings: Submit for approval the following:
- Elevation for each style window and door specified;
- indicate sizes, glazing types, muntin types and
- designs.
- Schedule: Indicate each window and door in project;
- reference each unit to specific elevation style.
- Details: Head, jamb, and sill details for each project
- condition.
-
- D. Selection Samples: Manufacturer's full range of
- available colors.
-
- E. Verification Samples: Operating units of each style
- window and door specified; verification samples may be
- operating scaled-down mock-ups of actual-size units.
- Verification samples will be returned to manufacturer's
- representative at project closeout.
-
- F. Quality Assurance Submittals: Evidence of certifications
- of window units required in QUALITY ASSURANCE Article of
- this section.
-
- 1.5 QUALITY ASSURANCE
-
- A. Qualifications:
- 1. Manufacturer: Minimum three years documented
- experience producing products specified in this
- section.
- 2. Installer: Minimum three years documented experience
- installing products specified in this section.
-
- B. Certifications: Provide window units independently
- tested and certified for air infiltration, water
- penetration, and structural performance by AAMA, for
- thermal transmission and solar heat gain performance by
- NFRC, and insulating glass certified by ALI/IGCC, to ASTM
- E 774, Class CBA.
-
- 1.6 DELIVERY, STORAGE, AND HANDLING
-
- A. Protect products from moisture, construction traffic, and
- damage in accord with manufacturer's instructions.
-
- B. Do not use non-vented plastic or canvas shelters; provide
- 1/4-inch (6.3 mm) space between units to promote air
- circulation.
-
- 1.7 WARRANTY
-
- A. Manufacturer's Warranty: Furnish manufacturer's Lifetime
- Limited Warranty on window products, including five year
- SureStart Protection, transferable to subsequent owners.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: CertainTeed Corporation, Vinyl
- Building Products Group, or any of its licensed regional
- fabricators; 750 E. Swedesford Road, P.O. Box 860, Valley
- Forge, PA 19482; ASD. Tel. (800) 233-8990.
- NOTE ** Delete one of the two paragraphs below; coordinate
- with Division 1 requirements.
-
- B. Requests for substitutions will be considered in
- accordance with provisions of Section 01600.
-
- C. Substitutions: Not permitted.
-
- 2.2 COMPONENTS
-
- A. Window Frame and Sash Members: Impact resistant,
- exterior grade polyvinyl chloride extrusions complying
- with AAMA 303 and ASTM D 4726.
- 1. Ignition temperature, when tested in accordance with
- ASTM D 1929: Minimum of 824 degrees F (440 degrees
- C).
- 2. Flammability, when tested in accordance with ASTM D
- 635: Burn time of less than 5 seconds and burn
- distance of less than 10 mm.
- 3. Non-corroding, non-flaking, non-chipping, non-
- rotting; no electrical conductance; low thermal
- conductance
- 4. Minimum external wall thickness: 0.070 inch (1.8 mm)
- nominal.
- 5. Finish of sight-exposed surfaces: Smooth gloss
- finish with uniform consistent color.
- NOTE ** Standard factory glazing for New Castle single-
- hung, gliding, fixed and Architectural Shape window
- units is 5/8 inch (16 mm) insulating unit with 3/32
- inch (2.5 mm) thick or 1/8 inch (3 mm) thick clear
- inner pane and outer pane (depending on window unit
- size and specified AAMA 101 grade requirements),
- with hermetically sealed air space and low-
- conductance spacer.
- NOTE **
- NOTE ** Standard factory glazing for New Castle casement,
- fixed casement, and awning window units is 7/8 inch
- (22 mm) insulating unit with 3/32 inch (2.5 mm)
- thick or 1/8 inch (3 mm) thick clear inner pane and
- outer pane (depending on window unit size and
- specified AAMA 101 grade requirements), with
- hermetically sealed air space and low-conductance
- spacer.
- NOTE ** Standard factory glazing for New Castle XT double-
- hung, double-gliding, fixed, and Architectural
- Shape window units is 7/8 inch (22 mm) insulating
- unit with 3/32 inch (2.5 mm) thick or 1/8 inch (3
- mm) thick clear inner pane and outer pane
- (depending on window unit size and specified AAMA
- 101 grade requirements), with hermetically sealed
- air space and low-conductance spacer.
- NOTE **
- NOTE ** Despite the fact that standard factory glazing is
- as indicated above, window size and local codes may
- require specifying one of the following glass
- thickness (strength) options:
- NOTE **
- NOTE ** Increased thickness to 1/8 inch (3 mm), 5/32 inch
- (4 mm), or 3/16 inch (5 mm).
- NOTE ** Heat-strengthened or tempered glass.
- NOTE ** If more than one type of insulating glass unit is
- required for project, copy paragraph below,
- designate unit styles, coordinate with drawings,
- schedule article, and window style article.
- NOTE **
- NOTE ** Edit paragraph below for specified requirements.
- NOTE **
- NOTE ** Glass color options are: Clear, green, bronze,
- blue, grey, obscure. Other colors may be
- available.
-
- B. Insulating Unit Type __: Complying with ASTM E 774,
- Class CBA; unit thickness ___ inch (___ mm):
- 1. Outer Pane: ____ inch (___ mm) thick glass, clear
- color.
- NOTE ** Delete the following paragraph if low-emissivity
- coating is not required.
- 2. Outer Pane Coating: Thermaflect(R) double sputter-
- coat high-performance low-emissivity softcoat on air
- chamber side of pane.
- NOTE ** Delete one of the following two paragraphs, to
- specify air space filled with plain air or with
- Argon gas.
- 3. Air Chamber: Hermetically sealed space between
- panes, low-conductance spacer, desiccated butyl or
- polyisobutylene chamber sealant.
- 4. Air Chamber: Hermetically sealed space between
- panes, low-conductance spacer, desiccated butyl or
- polyisobutylene chamber sealant, Argon gas filled to
- minimum 97 percent initial fill.
- 5. Inner Pane: ____ inch (___ mm) thick glass, clear
- color.
- NOTE ** Consult manufacturer's product data for thermal
- performance of window styles and glazing options;
- coordinate with window styles and glazing
- selections.
- 6. Thermal Performance:
- a. Total Unit U-Value: ____ (__ metric equivalent).
- b. Daylight Transmittance: ____ percent.
- c. Ultraviolet Block: ____.
- d. Shading Coefficient: ____.
-
- C. Screens: Type installable from interior side, providing
- only reasonable insect control when operable sash is in
- open position; re-wirable glass fiber mesh, 14 x 18 mesh,
- secured in channel of aluminum box frame with continuous
- vinyl spline; frame color matching frame and sash
- interior color.
-
- D. Operating Hardware: Types for specified operable-sash
- windows; sight-exposed hardware of UV-stabilized
- engineered polycarbonate plastic, color matched to vinyl
- extrusions for uniform appearance.
-
- E. Fasteners: Corrosion-resistant, and conforming to ASI
- B18-6-4.
-
- F. Weatherstripping: Types for specified operable-sash
- windows and operable doors.
- NOTE ** Delete or retain one or both paragraphs below for
- specified window units.
-
- G. Integral Muntins: Aluminum, pre-finished to match window
- frame, factory-mounted between panes of insulating glass
- unit before sealing glass unit.
-
- H. Applied Muntins: Polyvinyl chloride (PVC), color
- matching window frame, applied to interior side of window
- using proprietary attachment system.
-
- 2.3 SINGLE HUNG WINDOWS
-
- A. Acceptable Product: New Castle Single-Hung.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ cubic feet per minute (__
- cu m/hr).
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-punched
- nailing fin four sides; integral weep system; tilt-in
- lower sash interlocking to stay bar, with surface-
- mounted tilt latches and molded-in lift rail; one
- operable lower sash, one upper fixed sash.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper meeting
- forced entry resistance requirements of CAWM 301,
- engineered to force meeting rails together, for
- minimum air infiltration.
- b. Balances: Stainless steel constant-force spring
- balances, 3/4 inch (19 mm) wide, meeting AAMA
- 902, providing maintenance free operation without
- post-installation adjustment or lubrication.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701; compression-type bulb seal at lower
- rail meeting sill.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- B. Acceptable Product: New Castle Twin Single-Hung and
- Triple Single-Hung; combined single-hung units.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ cubic feet per minute (__
- cu m/hr).
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Common frame and
- integral reinforced jamb/mullion system for improved
- structural performance and trimmer lines; mitered and
- fusion-welded corners; integral 1 inch (25.4 mm) pre-
- punched nailing fin four sides; integral weep system;
- tilt-in lower sash interlocking to stay bar, with
- surface-mounted tilt latches and molded-in lift rail;
- one operable lower sash, one upper fixed sash.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper meeting
- forced entry resistance requirements of CAWM 301,
- engineered to force meeting rails together, for
- minimum air infiltration.
- b. Balances: Stainless steel constant-force spring
- balances, 3/4 inch (19 mm) wide, meeting AAMA
- 902, providing maintenance free operation without
- post-installation adjustment or lubrication.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701; compression-type bulb seal at lower
- rail meeting sill.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.4 DOUBLE-HUNG WINDOWS
-
- A. Acceptable Product: New Castle XT Double-Hung.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners, with molded-in receptor pockets for
- interior and exterior trim; welded sloped sill with 1
- inch (25.4 mm) high welded sill dam; 1 inch (25.4 mm)
- pre-punched nailing fin four sides; integral weep
- system; tilt-in upper and lower sash with recess-
- mounted tilt latches; integral glazing provision for
- exterior glazing bead; lower sash with molded-in lift
- rail; operable lower and upper sash.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper, engineered
- to force meeting rails together to minimize air
- infiltration.
- b. Balances: Stainless steel constant-force spring
- balances, 3/4 inch (19 mm) wide, meeting AAMA
- 902, providing maintenance free operation without
- post-installation adjustment or lubrication.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701; compression-type bulb seal at lower
- rail meeting sill.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.5 HORIZONTAL GLIDING WINDOWS
- NOTE ** The following paragraph specifies New Castle Glider
- window with single operable sash; delete if not
- required.
-
- A. Acceptable Product: New Castle Glider.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-punched
- nailing fin four sides; integral weep system;
- integral glazing provision; molded-in glide rail;
- operable sash interlocks to the staybar; one operable
- sash, one fixed sash.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper meeting
- forced entry resistance requirements of CAWM 301,
- engineered to force meeting stiles/rails, with
- interlock for minimum air infiltration.
- NOTE ** Delete one of two paragraphs below.
- b. Glides: Glide pads on track.
- c. Glides: Glide rollers on track.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
- NOTE ** The following paragraph specifies New Castle XT
- Glider window with both sashes operable; delete if
- not required.
-
- B. Acceptable Product: New Castle XT Glider.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners, with molded-in receptor pockets for
- interior and exterior trim; integral 1 inch (25.4 mm)
- pre-punched nailing fin four sides; independent weep
- system for interior and exterior glide tracks;
- integral glazing provision for exterior glazing bead;
- molded-in glide rail; both sashes operable; sashes
- lifting out for cleaning from inside; sashes non-
- removable from outside.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper, engineered
- to force meeting rails together to minimize air
- infiltration.
- NOTE ** Delete one of two paragraphs below.
- b. Glides: Glide pads on track.
- c. Glides: Glide rollers on track.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.6 CASEMENT WINDOWS
-
- A. Acceptable Product: New Castle Casement.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-punched
- nailing fin four sides; integral weep system;
- integral glazing provision.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Operator: Gear-actuated rotary operator and
- handle.
- b. Locks: Single-lever actuated, with multiple
- locking points, meeting forced entry resistance
- requirements of CAWM 301.
- 5. Weatherstripping: Double-row low-compression set
- bulb gaskets.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.7 AWNING WINDOWS
-
- A. Acceptable Product: New Castle Awning.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-punched
- nailing fin four sides; integral weep system;
- integral glazing provision.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Operator: Gear-actuated rotary operator and
- handle.
- b. Locks: Single-lever actuated, meeting forced
- entry resistance requirements of CAWM 301, with
- multiple locking points.
- 5. Weatherstripping: Double-row low-compression set
- bulb gaskets.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.8 BOW WINDOWS
-
- A. Acceptable Product: New Castle Casement Bow.
- 1. Operable-sash Windows:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- 5) Operating Force: ____ pounds (__ kg).
- b. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25 mm) pre-
- punched nailing fin; integral weep system;
- integral glazing provision.
- c. Factory Glazing: Insulating Glass Unit, Type
- ___.
- d. Operating Hardware:
- 1) Operator: Gear-actuated rotary operator and
- handle.
- 2) Locks: Single-lever actuated, meeting forced
- entry resistance requirements of CAWM 301,
- with multiple locking points.
- e. Weatherstripping: Double-row low-compression set
- bulb gaskets.
- f. Screens: Frame color matching window frame and
- sash interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- g. Muntins: Applied.
- h. Muntins: Integral.
- 2. Fixed-Sash Windows:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- b. Frame: Construction and profile matching
- operable-sash units; insulating glazing unit
- secured in integral glazing provision in frame.
- c. Factory Glazing: Insulating Glass Unit, Type
- ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- d. Muntins: Applied.
- e. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 3. Color: ________.
- 4. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 5. Styles and Sizes: Indicated on Drawings.
- 6. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- B. Installation Hardware: Threaded-rod mullion support
- system, adjustable.
-
- C. Headboard and Seatboard: Birch, vinyl-backed, insulated.
-
- 2.9 BAY WINDOWS
- NOTE ** The following paragraph specifies New Castle Bay
- window with fixed center window and single-hung
- flanker windows; delete if not required.
-
- A. Acceptable Product: New Castle Bay; Fixed Center, Single-
- Hung Flankers.
- 1. Fixed Center Window:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- b. Frame Construction: Mitered and fusion-welded
- corners; integral weep system; insulating glazing
- unit secured in integral glazing provision in
- frame.
- c. Factory Glazing: Insulating Glass Unit, Type
- ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- d. Muntins: Applied.
- e. Muntins: Integral.
- 2. Single-Hung Flanker Windows:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- 5) Operating Force: ____ pounds (__ kg).
- NOTE ** Delete one of two paragraphs below.
- b. Projection: 30 degrees from wall plane.
- c. Projection: 45 degrees from wall plane.
- d. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-
- punched nailing fin; integral weep system; tilt-
- in lower sash with integral lift rails; integral
- glazing provision; lower sash interlocks to the
- stay bar; one operable lower sash, one upper
- fixed sash.
- e. Factory Glazing: Insulating Glass Unit, Type
- ___.
- f. Operating Hardware:
- 1) Locks: Cam-type sash lock and keeper meeting
- forced entry resistance requirements of CAWM
- 301, engineered to force meeting rails
- together to minimize air infiltration.
- 2) Balances: Stainless steel constant-force
- spring balances, 3/4 inch (19 mm) wide,
- meeting AAMA 902, providing maintenance free
- operation without post-installation
- adjustment or lubrication.
- g. Weatherstripping: Double-row high-density
- silicone-treated polypropylene pile, with double
- mylar fin, meeting AAMA 701; compression-type
- bulb seal at lower rail meeting sill.
- h. Screens: Frame color matching window frame and
- sash interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- i. Muntins: Applied.
- j. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 3. Color: ________.
- 4. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 5. Styles and Sizes: Indicated on Drawings.
- 6. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
- NOTE ** The following paragraph specifies New Castle Bay
- window with fixed center window and casement
- flanker windows; delete if not required.
-
- B. Acceptable Product: New Castle Bay; Fixed Center,
- Casement Flankers.
- 1. Fixed Center Window:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- b. Frame Construction: Mitered and fusion-welded
- corners; integral weep system; insulating glazing
- unit secured in integral glazing provision in
- frame.
- c. Factory Glazing: Insulating Glass Unit, Type
- ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- d. Muntins: Applied.
- e. Muntins: Integral.
- 2. Casement Flanker Windows:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- 5) Operating Force: ____ pounds (__ kg).
- NOTE ** Delete one of two paragraphs below.
- b. Projection: 30 degrees from wall plane.
- c. Projection: 45 degrees from wall plane.
- d. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-
- punched nailing fin; integral weep system;
- integral glazing provision.
- e. Factory Glazing: Insulating Glass Unit, Type
- ___.
- f. Operating Hardware:
- 1) Operator: Gear-actuated rotary operator and
- handle.
- 2) Locks: Single-lever actuated, with multiple
- locking points, meeting forced entry
- resistance requirements of CAWM 301.
- g. Weatherstripping: Double-row low-compression set
- bulb gaskets.
- h. Screens: Frame color matching window frame and
- sash interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- i. Muntins: Applied.
- j. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 3. Color: ________.
- 4. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 5. Styles and Sizes: Indicated on Drawings.
- 6. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
- NOTE ** The following paragraph specifies New Castle XT Bay
- window with fixed center window and double-hung
- flanker windows; delete if not required.
-
- C. Acceptable Product: New Castle XT Bay; Fixed Center,
- Double-Hung Flankers.
- 1. Fixed Center Window:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- b. Frame Construction: Mitered and fusion-welded
- corners with molded-in receptor pockets for
- interior an exterior trim; 1 inch (25 mm) pre-
- punched nailing fin; integral weep system;
- insulating glazing unit secured in integral
- glazing provision in frame.
- c. Factory Glazing: Insulating Glass Unit, Type
- ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- d. Muntins: Applied.
- e. Muntins: Integral.
- 2. Double-Hung Flanker Windows:
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- a. Unit performance when tested in accordance with
- AAMA 101:
- 1) Air Infiltration: ____ cubic feet per minute
- (__ cu m/hr).
- 2) Water Penetration: ____ pounds per square
- foot (__ kPa) pressure before water leakage.
- 3) Structural Performance: ____ pounds per
- square foot (__ kPa).
- 4) Overall Rating: Grade __.
- 5) Operating Force: ____ pounds (__ kg).
- NOTE ** Delete one of two paragraphs below.
- b. Projection: 30 degrees from wall plane.
- c. Projection: 45 degrees from wall plane.
- d. Frame and Sash Construction: Mitered and fusion-
- welded corners, with molded-in receptor pockets
- for interior and exterior trim; welded sloped
- sill with 1 inch (25.4 mm) high welded sill dam;
- 1 inch (25.4 mm) pre-punched nailing fin;
- integral weep system; tilt-in upper and lower
- sash with recess-mounted tilt latches; integral
- glazing provision for exterior glazing bead;
- lower sash with molded-in lift rail; operable
- lower and upper sash.
- e. Factory Glazing: Insulating Glass Unit, Type
- ___.
- f. Operating Hardware:
- 1) Locks: Cam-type sash lock and keeper,
- engineered to force meeting rails together to
- minimize air infiltration.
- 2) Balances: Stainless steel constant-force
- spring balances, 3/4 inch (19 mm) wide,
- meeting AAMA 902, providing maintenance free
- operation without post-installation
- adjustment or lubrication.
- g. Weatherstripping: Double-row high-density
- silicone-treated polypropylene pile, with double
- mylar fin, meeting AAMA 701; compression-type
- bulb seal at lower rail meeting sill.
- h. Screens: Frame color matching window frame and
- sash interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- i. Muntins: Applied.
- j. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 3. Color: ________.
- 4. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 5. Styles and Sizes: Indicated on Drawings.
- 6. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- D. Installation Hardware: Threaded-rod mullion support
- system, adjustable.
-
- E. Headboard and Seatboard: Birch, vinyl-backed, insulated.
-
- 2.10 OPERABLE EXTENDED ARCH WINDOWS
-
- A. Acceptable Product: New Castle Operable Extended Arch.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction: Mitered and fusion-
- welded corners; integral 1 inch (25.4 mm) pre-punched
- nailing fin four sides; integral weep system; tilt-in
- lower sash with surface-mounted tilt latches;
- integral glazing provision; lower sash with molded-in
- lift rail; one operable lower sash, one upper fixed
- sash.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- 4. Operating Hardware:
- a. Locks: Cam-type sash lock and keeper meeting
- forced entry resistance requirements of CAWM 301,
- engineered to force meeting rails together to
- minimize air infiltration.
- b. Balances: Stainless steel constant-force spring
- balances, 3/4 inch (19 mm) wide, meeting AAMA
- 902, providing maintenance free operation without
- post-installation adjustment or lubrication.
- 5. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701; compression-type bulb seal at lower
- rail meeting sill.
- 6. Screens: Frame color matching window frame and sash
- interior color.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 7. Muntins: Applied.
- 8. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 9. Color: ________.
- 10. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 11. Styles and Sizes: Indicated on Drawings.
- 12. Styles and Sizes: Indicated in SCHEDULES Article in
- PART 3 of this section.
-
- 2.11 FIXED GEOMETRIC WINDOWS
- NOTE ** New Castle Architectural Shape(tm) windows include
- a variety of shapes and associated muntin designs
- and have a frame design which compliments other New
- Castle window styles. Consult manufacturer's
- product literature for available options.
- NOTE **
- NOTE ** The principal differences between the New Castle
- and New Castle XT Architectural Shape windows are
- the frame profile and the glazing thickness: New
- Castle has 5/8 inch glazing, while New Castle XT
- has 7/8 inch glazing.
-
- A. Acceptable Product: New Castle Architectural Shape
- Windows, Style _________.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- 2. Frame Construction: Mitered and fusion-welded
- corners; integral weep system; insulating glazing
- unit secured in integral glazing provision in frame.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 4. Muntins: Applied.
- 5. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 6. Color: ________.
- 7. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 8. Styles, Patterns, and Sizes: Indicated on Drawings.
- 9. Styles, Patterns, and Sizes: Indicated in SCHEDULES
- Article in PART 3 of this section.
- NOTE ** New Castle XT Architectural Shape(tm) windows
- include a variety of shapes and associated muntin
- designs and have a frame design which compliments
- other New Castle XT window styles. Consult
- manufacturer's product literature for available
- options.
-
- B. Acceptable Product: New Castle XT Architectural Shape
- Windows, Style _________.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- 2. Frame Construction: Mitered and fusion-welded
- corners, with molded-in receptor pockets for interior
- and exterior trim; integral weep system; insulating
- glazing unit secured in integral glazing provision in
- frame; exterior glazing bead.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 4. Muntins: Applied.
- 5. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 6. Color: ________.
- 7. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 8. Styles, Patterns, and Sizes: Indicated on Drawings.
- 9. Styles, Patterns, and Sizes: Indicated in SCHEDULES
- Article in PART 3 of this section.
-
- 2.12 FIXED WINDOWS AND TRANSOMS
-
- A. Acceptable Product: New Castle Fixed windows.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- 2. Frame Construction: Profile to complement New Castle
- Single Hung and Glider windows; mitered and fusion-
- welded corners; integral weep system; insulating
- glazing unit secured in integral glazing provision in
- frame.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 4. Muntins: Applied.
- 5. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 6. Color: ________.
- 7. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 8. Styles, Patterns, and Sizes: Indicated on Drawings.
- 9. Styles, Patterns, and Sizes: Indicated in SCHEDULES
- Article in PART 3 of this section.
-
- B. Acceptable Product: New Castle Casement Fixed windows.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- 2. Frame Construction: Profile to complement New Castle
- Casement windows; insulating glazing unit secured in
- integral glazing provision in frame.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 4. Muntins: Applied.
- 5. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 6. Color: ________.
- 7. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 8. Styles, Patterns, and Sizes: Indicated on Drawings.
- 9. Styles, Patterns, and Sizes: Indicated in SCHEDULES
- Article in PART 3 of this section.
-
-
- C. Acceptable Product: New Castle XT Fixed windows.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- 2. Frame Construction: Profile to complement New Castle
- XT Double Hung and Glider windows; mitered and fusion-
- welded corners with molded-in receptor pockets for
- interior and exterior trim; integral weep system;
- insulating glazing unit secured in integral glazing
- provision in frame.
- 3. Factory Glazing: Insulating Glass Unit, Type ___.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 4. Muntins: Applied.
- 5. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 6. Color: ________.
- 7. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 8. Styles, Patterns, and Sizes: Indicated on Drawings.
- 9. Styles, Patterns, and Sizes: Indicated in SCHEDULES
- Article in PART 3 of this section.
-
- 2.13 PATIO DOORS
-
- A. Acceptable Product: New Castle Patio Door.
- NOTE ** Consult manufacturer's product data for performance
- of window styles; coordinate with window
- selections.
- 1. Unit performance when tested in accordance with AAMA
- 101:
- a. Air Infiltration: ____ cubic feet per minute (__
- cu m/hr).
- b. Water Penetration: ____ pounds per square foot
- (__ kPa) pressure before water leakage.
- c. Structural Performance: ____ pounds per square
- foot (__ kPa).
- d. Overall Rating: Grade __.
- e. Operating Force: ____ pounds (__ kg).
- 2. Frame and Sash Construction:
- a. Mitered and fusion-welded corners; integral 1
- inch (25.4 mm) pre-punched nailing fin four
- sides; integral weep system; integral glazing
- provision.
- b. Stiles: Aluminum reinforced; interlocking
- meeting stiles.
- c. Fixed Units: Frame profile matching operable
- units; fixed insulating glazing unit secured in
- integral glazing provision in frame.
- 3. Glazing: Insulating Unit, thickness 7/8 inch (22.2
- mm):
- a. Inner Pane: Tempered 1/8 inch (3 mm) thick
- glass, clear color.
- b. Hermetically sealed air space between panes;
- argon gas-filled, with low conductance spacer.
- c. Outer Pane: Tempered 1/8 inch (3 mm) thick
- glass, clear color; manufacturer's proprietary
- Thermaflect double sputter-coated high
- performance low-emissivity coating on air-space
- side.
- NOTE ** Retain the preceding three sub-paragraphs, or the
- following three sub-paragraphs, to specify glazing
- required for project.
- d. Outer Pane: Tempered 1/8 inch (3 mm) thick
- glass, clear color.
- e. Hermetically sealed air space between panes, with
- low conductance spacer.
- f. Inner Pane: Tempered 1/8 inch (3 mm) thick
- glass, clear color.
- 4. Operating Hardware:
- a. Roller Track: Anodized aluminum, thermally
- broken, with stainless steel cap.
- b. Rollers: Adjustable tandem stainless steel
- rollers.
- c. Stops: Anti-lift, preventing operable sash to be
- removed from exterior.
- NOTE ** Retain one of the following three sub-paragraphs to
- specify lock type.
- d. Locks: Single-lever actuated two-point locking;
- catch at locking points, meeting forced entry
- resistance requirements of CAWM 301; lock key-
- actuated from exterior; white baked enamel
- handle.
- e. Locks: Single-lever actuated three-point
- locking; steel rods through head and sill, catch
- at locking point, meeting forced entry resistance
- requirements of CAWM 301; lock key-actuated from
- exterior; white baked enamel handle.
- f. Locks: Single-lever actuated three-point
- locking; steel rods through head and sill, catch
- at locking point, meeting forced entry resistance
- requirements of CAWM 301; lock key-actuated from
- exterior; European design with solid brass
- handle.
- NOTE ** Retain one or delete both paragraphs below for
- specified window units.
- 5. Muntins: Applied.
- 6. Muntins: Integral.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 7. Color: ________.
- 8. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- 9. Weatherstripping: Double-row high-density silicone-
- treated polypropylene pile, with double mylar fin,
- meeting AAMA 701.
- 10. Screens: Frame color matching window frame and sash
- interior color.
-
- 2.14 GARDEN WINDOWS
-
- A. Acceptable Product: CertainTeed Garden Window.
- 1. Fixed Center and Overhead Window:
- a. Frame: Solid vinyl extrusions; mitered and
- fusion-welded corners, with internal aluminum
- frame support; integral weep system; insulating
- glazing units secured in integral glazing
- provision in frame.
- b. Factory Glazing: Insulating glass unit, 7/8 inch
- (22.2 mm) unit thickness, with clear glass inner
- pane, clear glass outer pane with Thermaflect(R)
- double sputter-coated high performance coating on
- air chamber side, argon gas-filled air chamber,
- and low-conductance seal.
- 2. Casement Flanker Windows:
- a. Sash: Solid vinyl extrusions; mitered and fusion-
- welded corners.
- b. Factory Glazing: Insulating glass unit, 7/8 inch
- (22.2 mm) unit thickness, with clear glass inner
- pane, clear glass outer pane with Thermaflect(R)
- double sputter-coated high performance coating on
- air chamber side, argon gas-filled air chamber,
- and low-conductance seal.
- c. Operating Hardware:
- 1) Operator: Gear-actuated rotary operator and
- handle.
- 2) Locks: Single-lever actuated, with multiple
- locking points, meeting forced entry
- resistance requirements of CAWM 301.
- d. Weatherstripping: Double-row low-compression set
- bulb gaskets.
- e. Screens: Frame color matching window frame and
- sash interior color.
- 3. Seatboard: Insulated, 2 inches (50 mm) thick, with
- birch interior capable of being field-finished.
- NOTE ** Delete one of two paragraphs below. Consult
- manufacturer's product data for available colors.
- 4. Color: ________.
- 5. Color: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** Delete one of two paragraphs below.
- 6. Sizes: Indicated on Drawings.
- 7. Sizes: Indicated in SCHEDULES Article in PART 3 of
- this section.
- NOTE ** The following is an option; delete paragraph if not
- required.
-
- B. Shelf: Clear tempered glass, on adjustable supports.
- NOTE ** Delete paragraphs specifying accessories not
- required in the following Article; delete entire
- Article if no accessories required.
-
- 2.15 ACCESSORIES
- NOTE ** Delete one of the following two paragraphs if
- mullions are required. The first is for New Castle
- windows, the second is for New Castle XT windows
- only.
-
- A. Mullions: Extruded rigid vinyl with concealed 16 gage
- galvanized steel or aluminum reinforcement; extruded
- rigid vinyl flashing clip; color to match adjacent window
- frames.
-
- B. Mullions: Structural mullion system complying with AAMA
- Grade deflection requirements for supported windows;
- extruded aluminum core; galvanized reinforcing strips if
- required; internal and external rigid PVC caps with
- compression gaskets; anchored to rough opening with
- reinforcement bracket; color to match adjacent window
- frames.
- NOTE ** The following paragraph specifies snap-in trim
- accessories available for New Castle XT windows;
- delete entire paragraph if New Castle XT windows
- are not specified. If paragraph is retained, edit
- listed items as applicable to project.
-
- C. Trim Accessories: Extruded rigid polyvinyl chloride (PVC)
- shapes for snap-in fit in molded-in receptor pockets in
- window frame:
- 1. J-channel for exterior siding up to 1/2 inch (12.8 mm)
- thick.
- 2. J-channel for exterior siding up to 3/4 inch (19mm)
- thick.
- 3. Return for interior drywall up to 1/2 inch (12.8 mm)
- thick.
- 4. Return for interior wood trim up to 3/4 inch (19mm)
- thick.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Have installer verify that project conditions are
- acceptable before beginning installation of products;
- verify that rough openings are as indicated, and are
- correct sizes for clearance spaces specified in
- manufacturer's instructions.
-
- B. Correct unacceptable conditions before proceeding with
- installation.
-
- 3.2 INSTALLATION
-
- A. Install products in accordance manufacturer's
- instructions and approved shop drawings.
-
- B. Install products plumb and in true alignment; fasten to
- achieve maximum operational effectiveness and appearance
- of units.
-
- 3.3 ADJUSTING
-
- A. Ensure that windows and doors operate correctly, free
- from binding or other defects.
-
- 3.4 CLEANING
-
- A. Clean and restore soiled surfaces; remove scraps and
- debris, and leave site in clean condition.
-
- 3.5 SCHEDULE
- NOTE ** Below are suggested schedule formats, if Schedule
- has been referenced in previous articles. Consult
- manufacturer's product data for available colors
- and callout sizes. Coordinate Style designations
- with drawings.
-
- A. Window Schedule:
- 1. Window Style ___:
- a. Style: Casement-Fixed-Casement, with Transom.
- b. Callout Size: CFC5436.
- c. Color: Tan.
- 2. Window Style ___:
- a. Style: Geometric Half-Round, with Starburst
- muntin pattern.
- b. Callout Size: HR6030.
- c. Color: Tan.
-
- B. Patio Door Schedule:
- 1. Door Style ___:
- a. Style: OX, outside view.
- b. Callout Size: PD7280.
- c. Color: Tan.
-
-
- END OF SECTION
-