home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 08335qmi.txt < prev    next >
Encoding:
Text File  |  1998-06-10  |  11.0 KB  |  316 lines

  1.                          SECTION 08335
  2.  
  3.                    COILING SECURITY SHUTTERS
  4.  
  5. NOTE ** QMI PVC, aluminum, and steel counter and security
  6.         shutters for commercial and residential use.
  7. NOTE **
  8. NOTE ** This section is based on products manufactured by:
  9. NOTE **     QMI Roll Shutter Supply
  10. NOTE **     933 North Oaklawn Avenue
  11. NOTE **     Elmhurst, Illinois 60126
  12. NOTE **     Tel:  (800) 446-2500
  13. NOTE **     Fax:  (630) 782-1911
  14. NOTE **
  15. NOTE ** QMI Roll Shutter Supply's product line of HomeSafe,
  16.         CounterSafe, and StoreSafe Rolling Shutters offer a
  17.         full selection of PVC, aluminum, and steel shutters
  18.         for use in commercial applications and residential
  19.         security.
  20. NOTE **
  21. NOTE ** SECTION 08835 - Coiling Security Shutters,
  22.         Copyright 1997, The Architect's Catalog, Inc.
  23.  
  24. PART 1  GENERAL
  25.  
  26. 1.1 SECTION INCLUDES
  27. NOTE ** Delete items below not required for project.
  28.  
  29.     A.  Coiling Security Shutters.
  30.  
  31.     B.  Mechanical Operators.
  32.  
  33.     C.  Electrical Operators.
  34.  
  35. 1.2 RELATED SECTIONS
  36. NOTE ** Delete any sections below not relevant to this
  37.         project; add others as required.
  38.  
  39.     A.  Section 06100 - Rough Carpentry.
  40.  
  41.     B.  Section 06200 - Finish Carpentry.
  42.  
  43.     C.  Section 16050 - Basic Electrical Materials and Methods.
  44.  
  45. 1.3 SUBMITTALS
  46.  
  47.     A.  Submit under provisions of Section 01300.
  48.  
  49.     B.  Product Data:  Manufacturer's product literature.
  50.  
  51.     C.  Selection Samples:  Manufacturer's full range of
  52.         available colors in material specified.
  53.  
  54.     D.  Shop Drawings:  Indicate type of curtain, number of
  55.         panels, housing, rails, storm rails, and operators.
  56.  
  57. 1.4 QUALITY ASSURANCE
  58.  
  59.     A.  Manufacturer's Qualifications:  Minimum five years of
  60.         documented experience producing products of the type
  61.         specified in this section.
  62.  
  63.     B.  Installer's Qualifications:  Minimum three years of
  64.         documented experience installing products of the type
  65.         specified in this section.
  66.  
  67.     C.  Certifications:  Provide shutters rated and certified.
  68.  
  69. 1.5 DELIVERY, STORAGE, AND HANDLING
  70.  
  71.     A.  Pack and load shutters using reasonable and customary
  72.         precautions against damage in transit; do not use
  73.         materials for packing or blocking that may stain, damage,
  74.         or discolor shutters.
  75.  
  76.     B.  Store in original packaging under cover until
  77.         installation.
  78.  
  79.  
  80. PART 2  PRODUCTS
  81.  
  82. 2.1 MANUFACTURERS
  83.  
  84.     A.  Acceptable Manufacturer:  QMI Roll Shutter Supply; 933
  85.         North Oaklawn Avenue, Elmhurst, Illinois  60126; ASD.
  86.         Tel:  (800) 446-2500; Fax:  (630) 782-1911.
  87. NOTE ** Delete one of the two paragraphs below; coordinate
  88.         with Division 1 requirements.
  89.  
  90.     B.  Requests for substitutions will be considered in
  91.         accordance with provisions of Section 01600.
  92.  
  93.     C.  Substitutions:  Not permitted.
  94.  
  95. 2.2 COMPONENTS
  96.  
  97.     A.  Curtains:  Extruded double walled polyvinyl chloride
  98.         slats.
  99. NOTE ** Delete all but one of the slat height paragraphs
  100.         below.
  101. NOTE **
  102. NOTE ** Slat type  Height        Width        Max Area
  103. NOTE **
  104. NOTE ** PV1/Mini   1.45 inches   78 inches    30 sq ft
  105. NOTE ** PV2/Mini   1.57 inches  120 inches    40 sq ft
  106. NOTE ** PV3/Maxi   2.06 inches  144 inches    65 sq ft
  107. NOTE ** PV4/Maxi   1.91 inches  168 inches    85 sq ft
  108. NOTE **
  109. NOTE ** Reinforcing bars are optional.
  110. NOTE ** PVC is NOT an appropriate option for heavy-duty
  111.         commercial installations.
  112. NOTE ** PV1/Mini is not recommended for any commercial
  113.         installations.
  114.         1.  Slat Height:  1.45 inches (37 mm).
  115.         2.  Slat Height:  1.57 inches (40 mm).
  116.         3.  Slat Height:  2.06 inches (52 mm).
  117.         4.  Slat Height:  1.91 inches (49 mm).
  118.         5.  Reinforcing Bars:  Manufacturer's standard galvanized
  119.             steel reinforcing bars in every third slat.
  120. NOTE ** Delete all but one of the color paragraphs below.
  121.         6.  Color:  White.
  122.         7.  Color:  Ivory.
  123.         8.  Color:  Beige.
  124.         9.  Color:  Grey.
  125.         10. Color:  As selected from manufacturer's full line.
  126.  
  127.     B.  Curtains:  Prefinished roll-formed aluminum slats.
  128. NOTE ** Delete all but one of the slat height paragraphs
  129.         below.
  130. NOTE **
  131. NOTE ** Slat type  Height       Width        Max Area
  132. NOTE **
  133. NOTE ** AL2/Mini   1.57 inches  180 inches    81 sq ft
  134. NOTE ** AL3/Maxi   2.06 inches  200 inches   105 sq ft
  135. NOTE **
  136. NOTE ** Delete one of the two insulation paragraphs below.
  137.         1.  Slat Height:  1.57 inches (40 mm).
  138.         2.  Slat Height:  2.06 inches (52 mm).
  139.         3.  Insulation:  Standard density.
  140.         4.  Insulation:  High density.
  141. NOTE ** Delete all but one of the color paragraphs below.
  142.         5.  Color:  White.
  143.         6.  Color:  Ivory.
  144.         7.  Color:  Beige.
  145.         8.  Color:  Grey.
  146.         9.  Color:  Brown.
  147.  
  148.     C.  Curtains:  Extruded double walled aluminum slats.
  149. NOTE ** Delete all but one of the slat height paragraphs
  150.         below.
  151. NOTE **
  152. NOTE ** Slat type     Height       Width       Max Sq Feet
  153. NOTE **
  154. NOTE ** AL2-E/Mini    1.57 inches  200 inches  105
  155. NOTE ** AL3-E/Maxi    2.06 inches  200 inches  105
  156. NOTE ** AL5-E/Maxi    2.40 inches  210 inches  110
  157. NOTE **
  158. NOTE ** AL5-E is not an option for residential
  159.         installation.
  160.         1.  Slat Height:  1.57 inches (40 mm).
  161.         2.  Slat Height:  2.06 inches (52 mm).
  162.         3.  Slat Height:  2.40 inches (61 mm).
  163. NOTE ** Delete all but one of the color paragraphs below.
  164.         4.  Color:  White.
  165.         5.  Color:  Ivory.
  166.         6.  Color:  Beige.
  167.         7.  Color:  Bronze.
  168.         8.  Color:  Brown.
  169.         9.  Color:  As selected from manufacturer's full line.
  170.  
  171.     D.  Curtains:  Roll-formed steel slats with CFC-free foam
  172.         insulation.
  173. NOTE ** Delete all but one of the slat height paragraphs
  174.         below.
  175. NOTE **
  176. NOTE ** Slat type   Height       Width       Max Area
  177. NOTE **
  178. NOTE ** ST2/Mini    1.57 inches  200 inches  105 sq ft
  179. NOTE ** ST3/Maxi    2.06 inches  200 inches  105 sq ft
  180. NOTE **
  181. NOTE ** ST3 is not an option for residential or commercial
  182.         counter installation.
  183.         1.  Slat Height:  1.57 inches (40 mm).
  184.         2.  Slat Height:  2.06 inches (52 mm).
  185. NOTE ** Delete all but one of the color paragraphs below.
  186.         3.  Color:  White.
  187.         4.  Color:  Brown.
  188.  
  189.     E.  Housing:  Square shutter upper box housing made from
  190.         0.040 inch (1.0 mm) pre-finished rolled formed aluminum
  191.         with cast aluminum end caps; size as specified by
  192.         manufacturer.
  193. NOTE ** Housing may be a different color from the curtain.
  194.         If so, delete all but one of the housing color
  195.         paragraphs below.  Otherwise, delete all the color
  196.         paragraphs completely.
  197.         1.  Color:  White.
  198.         2.  Color:  Brown.
  199.         3.  Color:  Beige.
  200.         4.  Color:  Cream.
  201.         5.  Color:  As selected from manufacturer's full line.
  202.  
  203.     F.  Side Rails:  Extruded 6063-T5 aluminum acid etched with
  204.         baked enamel finish, and lined with insulating woven
  205.         polypropylene runners.
  206. NOTE ** Rails may be a different color from the curtain.
  207.         If so, delete all but one of the rails color
  208.         paragraphs below.  Otherwise, delete all the color
  209.         paragraphs completely.
  210.         1.  Color:  White.
  211.         2.  Color:  Brown.
  212.         3.  Color:  Beige.
  213.         4.  Color:  Cream.
  214.         5.  Color:  As selected from manufacturer's full line.
  215.  
  216.     G.  Mullions:  Provide intermediate vertical mullions to
  217.         allow curtain width to maximum allowed by manufacturer.
  218.  
  219.     H.  Storm Bars:  Extruded 6063-T6 aluminum acid etched with
  220.         baked enamel finish and lined with insulating woven
  221.         polypropylene runners; removable.
  222. NOTE ** Storm bars may be a different color.  If so, delete
  223.         all but one of the storm bars color paragraphs
  224.         below.  Otherwise, delete all the color paragraphs
  225.         completely.
  226.         1.  Color:  White.
  227.         2.  Color:  Brown.
  228.         3.  Color:  Beige.
  229.         4.  Color:  Cream.
  230.         5.  Color:  Grey.
  231.         6.  Color:  As selected from manufacturer's full line.
  232. NOTE ** Delete the operators and option paragraphs not
  233.         required. If more than one type is required, edit
  234.         to indicate where each is to be used.
  235. NOTE **
  236. NOTE ** Manual Recoil Strap controls up to 25 lbs.
  237. NOTE ** 3-1 Strap Crank controls up to 45 pounds.
  238. NOTE **
  239. NOTE ** Manual Crank Geared system with pole operator
  240.         controls up to 80 pounds. Crank handle should be
  241.         located on drawing.
  242.  
  243.     I.  Operator:  Manual recoil strap.
  244.  
  245.     J.  Operator:  Manual strap with 3-1 ratio crank.
  246.  
  247.     K.  Operator:  Manual crank with self-lubricating hardened
  248.         steel gears.
  249.         1.  Removable pole operator.
  250.         2.  Fixed pole operator.
  251.  
  252.     L.  Operator:  Manual push-up with spring assist.
  253. NOTE ** Electric motors draw 1.5 to 3.5 amps depending on
  254.         size.  Standard actuator is rocker switch.  Delete
  255.         all other actuators not required.  Show location of
  256.         actuators on drawings unless the contractor may
  257.         locate them wherever is convenient.
  258.  
  259.     M.  Operator:  Electric motor; 120V, 60hz, single phase, size
  260.         as recommended by shutter manufacturer; with solenoid
  261.         activated breaking and thermal protection; UL labeled;
  262.         concealed in housing, actuated by:
  263.         1.  Single pole, double throw rocker switch.
  264.         2.  Remote actuator.
  265.         3.  Key switch.
  266.         4.  Sun sensor.
  267.         5.  Provide manual override in case of power outage, with
  268.             removable crank.
  269.         6.  Locate actuators where indicated on drawings.
  270.  
  271.     N.  Locking:  Automatic spring lock.
  272. NOTE ** Delete all of the following additional locking
  273.         mechanisms not required.
  274. NOTE **
  275. NOTE ** Slide bolts are installed in the bottom slat and
  276.         slide into the side rails to lock the shutter.
  277. NOTE **
  278. NOTE ** Key lock can be installed in the base slat or in
  279.         the curtain and can be keyed alike.
  280.         1.  Additional slide bolts in bottom slat.
  281.         2.  Keyed deadbolt in base slat.
  282.         3.  Keyed deadbolt in curtain.
  283.  
  284.     O.  Fasteners:  Stainless steel.
  285.  
  286.  
  287. PART 3  EXECUTION
  288.  
  289. 3.1 EXAMINATION
  290.  
  291.     A.  Verify openings are in accordance with approved shop
  292.         drawings.
  293.  
  294. 3.2 INSTALLATION
  295. NOTE ** Edit the following paragraph to delete "approved
  296.         shop drawings" if submittal of shop drawings is not
  297.         specified above.
  298.  
  299.     A.  Install coiling security shutters plumb and level in
  300.         accordance with code, approved shop drawings, and
  301.         manufacturer's printed installation instructions.
  302. NOTE ** Delete the mounting method paragraphs not required
  303.         for the project.
  304.  
  305.     B.  Surface mount shutters.
  306.  
  307.     C.  Flush mount shutters.
  308. NOTE ** Delete the following paragraph if electric motor
  309.         operator is not specified.
  310.  
  311.     D.  Installation of actuators for operator and connection of
  312.         electrical components are specified in Section 16050.