home *** CD-ROM | disk | FTP | other *** search
- SECTION 08333
-
- OVERHEAD COILING WOOD COUNTER DOORS
-
- NOTE ** This section is based on products manufactured by
- NOTE ** Woodfold-Marco Mfg., Inc., at the following
- address:
- NOTE ** P.O. Box 346
- NOTE ** Forest Grove OR 97116
- NOTE ** Tel: (503) 357-7181
- NOTE ** Fax: (503) 357-7185
- NOTE **
- NOTE ** Woodfold-Marco overhead coiling wood counter doors
- offer an attractive solution when both security
- requirements and aesthetic requirements must be
- met.
- NOTE **
- NOTE ** SECTION 08333 - OVERHEAD COILING WOOD COUNTER
- DOORS, Copyright 1998, The Architect's Catalog,
- Inc.
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Delete items below not required for project.
-
- A. Overhead Coiling Wood Counter Doors.
-
- B. Mechanical Operators.
-
- C. Electrical Operators.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 06100 - Rough Carpentry.
-
- B. Section 06200 - Finish Carpentry.
-
- C. Section 08710 - Door Hardware.
-
- D. Section 09900 - Paints and Coatings.
-
- E. Section 16050 - Basic Electrical Materials and Methods.
-
- 1.3 SYSTEM DESCRIPTION
- NOTE ** Edit the following paragraph for project
- requirements; if more than one type counter door is
- required, add a Counter Door Type designation to
- the first sentence, copy paragraph for as many
- counter door types required, and edit each
- paragraph accordingly. Coordinate requirements
- specified in this Article with items in COMPONENTS
- Article of PART 2.
-
- A. Design Requirements:
- NOTE ** Counter doors are available in Oak, Maple, Birch,
- Mahogany, and Cherry; other species can be
- specified also. Consult manufacturer for options.
- 1. Counter door wood species: _________________.
- NOTE ** Delete all but one of the following three
- sentences.
- 2. Counter door mounting: Inside mount, with coil and
- guide rails mounted between opening jambs.
- 3. Counter door mounting: Mixed mount, with coil
- mounted on face of wall, and guide rails mounted
- between opening jambs.
- 4. Counter door mounting: Outside mount, with coil
- mounted on face of wall, and guide rails mounted on
- face of wall at jambs.
- NOTE ** Delete all but one of the following three
- sentences. Crank or motor operators are available
- for large openings. Specify handing requirements
- for mechanical or electrical operator.
- 5. Counter door operation: Manual push-up.
- 6. Counter door operation: Manual crank operator, crank
- socket on _____-hand side of counter door as viewed
- from coil side.
- 7. Counter door operation: Electric motor operator on
- _____-hand side of counter door as viewed from coil
- side.
- 8. Opening size: Indicated on drawings.
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
- NOTE ** Delete all but one of the following three
- paragraphs:
- NOTE ** First paragraph is for counter door with motor
- operator.
- NOTE ** Second paragraph is for counter door with crank
- operator.
- NOTE ** Third paragraph is for push-up operated counter
- door.
-
- B. Product Data: Manufacturer's descriptive literature for
- counter door units, hardware, operators and controls;
- include power requirements.
-
- C. Product Data: Manufacturer's descriptive literature for
- counter door units, hardware, and operators.
-
- D. Product Data: Manufacturer's descriptive literature for
- counter door units and hardware.
- NOTE ** Delete one of the following two paragraphs:
- NOTE ** First paragraph is for counter door with motor
- operator.
- NOTE ** Second paragraph is for counter door with crank
- operator or push-up operated counter door.
-
- E. Shop Drawings: Indicate opening sizes, jamb, sill, and
- head conditions, control locations, and required
- locations for power source.
-
- F. Shop Drawings: Indicate opening sizes, jamb, sill, and
- head conditions.
- NOTE ** Delete the following paragraph if specifying custom
- species.
-
- G. Selection Samples: Two sets of wood species samples,
- representing manufacturer's full range of available
- species selection.
- NOTE ** Delete one of the two following paragraphs; second
- paragraph is for factory-finished assembly.
-
- H. Verification Samples: Two sample curtain slats, minimum
- size 8 inches in length, representing actual species and
- grain quality of installed product.
-
- I. Verification Samples: Two sample curtain slats, minimum
- size 8 inches in length, representing actual species,
- grain quality, and match to specified factory finish, of
- installed product.
-
- J. Quality Assurance Submittals: Printed installation
- instructions for specified counter door assembly.
-
- 1.5 DELIVERY, STORAGE, AND HANDLING
-
- A. Storage and Protection:
- 1. Store components in manufacturer's unopened packaging
- until installation.
- 2. Maintain dry, heated storage area for components
- installation.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: Woodfold-Marco Mfg., Inc.; P.O.
- Box 346, Forest Grove OR 97116; ASD. Tel: (503) 357-7181,
- Fax: (503) 357-7185.
- NOTE ** Delete one of the two following paragraphs;
- coordinate with Division 01 requirements.
-
- B. Requests for substitutions will be considered in
- accordance with provisions of Section 01600.
-
- C. Substitutions: Not permitted.
-
- 2.2 COMPONENTS
-
- A. Curtain:
- 1. Slats: Solid hardwood profiles with long edges
- rabbeted to interlock to form sight-proof curtain.
- 2. Bottom rail: Solid wood profile matching grain and
- species of slat.
- 3. Interlocking hardware: Manufacturer's standard,
- concealed within slat and bottom rail profile.
-
- B. Guides: Manufacturer's standard guides for indicated
- counter door mounting and operation.
- NOTE ** Delete the following paragraph if not required.
-
- C. Operator: Geared lifting and lowering mechanism with
- manual crank operator.
- NOTE ** Delete the following two paragraphs if not
- required.
-
- D. Operator: Tubular electric motor operator, 110VAC 60Hz
- power requirement.
-
- E. Operating Switch: Specified in Section 16050.
- NOTE ** Retain the following paragraph if specifying crank
- or motor operation and inside or mixed mounting.
-
- F. Guide Spacers: Manufacturer's standard spacers to allow
- clearance for gear box.
- NOTE ** Edit the following three paragraphs for latching
- requirements. Delete all three paragraphs if
- specifying electric operation.
-
- G. Latching Hardware: Manufacturer's standard sidebolt
- surface mounted to curtain bottom rail at each end of
- curtain.
-
- H. Latching Hardware: Deadbolt with thumbturn, mortised
- into curtain bottom rail on coil side of counter door.
-
- I. Latching Hardware:
- 1. Deadbolt with keylock, mortised into curtain bottom
- rail on coil side of counter door.
- NOTE ** Delete one of the following paragraphs; first
- paragraph applies if manufacturer supplies
- cylinders for locksets, second applies if cylinders
- for entire project are specified in Section 08710.
- 2. Supply two (2) keys for each lock.
- 3. Cylinders for keylocks are specified in Section
- 08710.
- NOTE ** Retain one or both of the following paragraphs if
- coil will be sight-exposed in the finished Work.
-
- J. Hood: Constructed of plywood, with veneer on sight-
- exposed face matching species of curtain material, or
- solid wood of same species as curtain material; concealed
- fastener construction to facilitate hood removal for
- servicing counter door.
-
- K. Fascia: Constructed of plywood, veneer on sight-exposed
- face matching species of curtain materials; concealed
- fastener attachment to facilitate fascia removal for
- servicing counter door.
-
- 2.3 FINISHES
-
- A. Sand sight-exposed wood surfaces to smooth finish.
- NOTE ** Delete all but one of the following three
- paragraphs.
- NOTE **
- NOTE ** Woodfold specializes in the factory finishing of
- components, using only environmentally safe
- finishing materials; factory finishing eliminates
- problems associated with handling of unfinished
- hardwood surfaces, and with time delays associated
- with site finishing.
- NOTE **
- NOTE ** If specifying custom finish in third paragraph,
- consult with manufacturer of counter door and
- manufacturer of finish material to specify
- finishing technique correctly.
-
- B. Application of final finish is specified in Section
- 09900.
-
- C. Apply clear polyurethane sealer to sight-exposed wood
- surfaces.
-
- D. Custom Finish: ___________________.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Verification of Conditions: Verify openings are in
- accordance with approved shop drawings.
-
- B. Installer's Examination:
- 1. Have installer of this section examine conditions
- under which construction activities of this section
- are to be performed, then submit written notification
- if such conditions are unacceptable.
- 2. Transmit two copies of installer's report to
- Architect within 24 hours of receipt.
- 3. Beginning construction activities of this section
- before unacceptable conditions have been corrected is
- prohibited.
- 4. Beginning construction activities of this section
- indicates installer's acceptance of conditions.
-
- 3.2 INSTALLATION
-
- A. Install counter doors plumb and level in accordance with
- approved shop drawings and manufacturer's printed
- installation instructions.
- NOTE ** Delete the following paragraph if electric operator
- is not specified.
-
- B. Installation of switch operator and connection of
- electrical components are specified in Section 16050.
-
- 3.3 ADJUSTING
-
- A. Adjust counter doors to operate correctly in accordance
- with manufacturer's product data.
-
-
- END OF SECTION
-