home *** CD-ROM | disk | FTP | other *** search
- SECTION 08162
-
- ICU/CCU SLIDING DOORS
-
- NOTE ** Dor-O-Matic, ICU/CCU-hospital sliding doors.
- NOTE **
- NOTE ** This section is based on the products of Dor-O-
- Matic, which is located at:
- NOTE ** 7530 W. Wilson Avenue
- NOTE ** Harwood Heights, IL 60656-4786
- NOTE ** Tel: (708) 867-7400
- NOTE ** Tel: (800) 543-4635
- NOTE ** Fax: (708) 867-0291
- NOTE **
- NOTE ** Dor-O-Matic is one of the oldest, most experienced,
- and most innovative manufacturers of automatic door
- equipment in the world. This section covers only a
- part of their product line: "ICU/CCU-Hospital"
- sliding doors with accompanying accessories,
- including necessary hardware. See their other
- sections for automatic swinging doors, automatic
- sliding doors, automatic folding doors, low-energy
- door operators, and fire door operators.
- NOTE **
- NOTE ** SECTION 08162 - ICU/CCU SLIDING DOORS, Copyright
- 1998, The Architect's Catalog, Inc.
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Select paragraphs below applicable to project.
- Standard header: 6-3/4 inches (170 mm) high, 4
- inches (100 mm) wide; Slim-Line header: 2-1/2
- inches (63 mm) high, 4-1/2 inches (114 mm) wide;
- Slim-Line Telescopic header: 2-1/2 inches (63 mm)
- high, 7 inches (178 mm) wide.
-
- A. Two-leaf sliding doors, panels, jambs, and hardware.
- 1. Standard.
- 2. Slim-Line.
- 3. With floor track.
- 4. Trackless.
-
- B. Three-leaf sliding doors, panels, jambs, and hardware.
- 1. Standard.
- 2. Slim-line.
- 3. Slim-Line telescopic.
- 4. With floor track.
- 5. Trackless.
-
- C. Four-leaf sliding doors, panels, jambs, and hardware.
- 1. Standard.
- 2. Slim-Line.
- 3. With floor track.
- 4. Trackless.
-
- D. Slim-Line telescopic six-leaf sliding doors, panels,
- jambs, and hardware.
- 1. With floor track.
- 2. Trackless.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete sections below not relevant to this project;
- add others as required.
-
- A. Section 03300 - Cast-in-Place Concrete: Preparation of
- concrete to accept recessed floor track.
-
- B. Section 07900 - Joint Sealers.
-
- C. Section 08800 - Glass and Glazing.
-
- D. Section _____ - ____________________________.
-
- 1.3 REFERENCES
- NOTE ** Add other references below as required.
-
- A. NFPA 101 - Safety to Life from Fire in Buildings and
- Structures.
-
- 1.4 DEFINITIONS
-
- A. SX Panel: Sliding panel which swings open upon pushing.
-
- B. SO Panel: Sidelite panel, normally stationary, which
- will swing open in an emergency.
- NOTE ** Include the following two paragraphs if trackless
- Slim-Line telescoping doors are required for the
- project.
-
- C. X Panel: Sliding panel in trackless Slim-Line
- telescoping doors, unable to swing.
-
- D. O Panel: Sidelite panel in trackless Slim-Line
- telescoping doors, unable to swing.
-
- 1.5 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Manufacturer's catalog data, detail
- sheets, and specifications.
-
- C. Shop Drawings: Prepared specifically for this project;
- show dimensions of doors, sidelites, details of
- construction, and interface with other products.
-
- D. Operating and Maintenance Data: Operating and
- maintenance instructions, and parts lists.
-
- 1.6 QUALITY ASSURANCE
-
- A. Installer Qualifications: Factory-trained, with minimum
- 3 years experience.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: Provide products made by Dor-O-
- Matic, 7350 West Wilson Avenue, Harwood Heights, IL 60656-
- 4786. ASD. Tel: (708) 867-7400 or (800) 543-4635. Fax:
- (708) 867-0291.
-
- B. Requests for substitutions will be considered in
- accordance with provisions of Section 01600.
- NOTE ** Delete paragraph above or below; coordinate with
- Division 1 requirements.
-
- C. Substitutions: Not permitted.
-
- D. Provide all ICU/CCU sliding doors from a single
- manufacturer.
-
- 2.2 DOORS AND FRAMES
- NOTE ** ICU/CCU-hospital sliding doors are available from
- Dor-O-Matic in complete packages, including
- aluminum doors, sidelites, frames, and hardware.
-
- A. Doors, Sidelites, Headers, and Trim: Extruded aluminum
- alloy 6063-T5, nominal 0.125 inch (3.17 mm) wall
- thickness.
- 1. Door and Sidelite Construction: Heavy-duty
- interlocked sections, through-rod bolted
- construction; steel corner support at hinge stile of
- carrier-suspended SX panels to eliminate sag in
- sliding or breakout mode.
- NOTE ** Include the following three subparagraphs for Slim-
- Line trackless doors (not for trackless
- telescoping).
- a. Combination Support Guide: SX panel.
- b. Roller Assembly: SO sidelite panel.
- c. Glass Jacking Screw Assembly: SO sidelite panel.
- NOTE ** Delete the following paragraph if electrical
- grounding is not required for the project.
- 2. Electrically ground sliding doors against static
- electricity.
- 3. Door Hanger Brackets: Nylon wheels with hardened
- steel bearings.
- NOTE ** Include the following paragraph for Standard doors.
- 4. Door Suspension System: SX breakout panels suspended
- over centerline of door.
- 5. Glazing Stops: 5/8 inch (15.87 mm) high.
- NOTE ** Include the following two paragraphs for Slim-Line
- trackless doors (not for trackless telescoping).
- 6. Pivot Base Plate: Under each SO sidelite panel.
- 7. Concealed Floating Pivots: In each panel.
- NOTE ** Select the first paragraph below for Standard doors
- with floor track, the second for Slim-Line doors
- with floor track, the third for trackless Slim-Line
- doors, and the fourth for Slim-Line telescopic
- doors (with or without floor track).
- 8. Headers: 6-3/4 inches (170 mm) high, 4 inches (100
- mm) wide, with full-width swing-out access cover.
- a. Built-in anti-riser system.
- 9. Headers: 2-1/2 inches (63 mm) high, 4-1/2 inches
- (114 mm) wide.
- a. Built-in anti-riser system.
- 10. Headers: 2-1/2 inches (63 mm) high, 4-1/2 inches
- (114 mm) wide with extruded aluminum stop bar mounted
- to underside in door opening to prevent SX panel from
- swinging until slid back to full position.
- a. Built-in anti-riser system.
- 11. Headers: 2-1/2 inches high (63 mm), 7 inches (178
- mm) wide.
- 12. Hardware: Door handles, recessed door pulls, and
- other hardware required for normal and emergency
- egress operation per NFPA 101.
- NOTE ** Select the first paragraph below for Standard doors
- with floor track, the second for Slim-Line doors
- with floor track, the third for trackless Slim-Line
- doors, the fourth for Slim-Line telescopic doors
- with floor track, and the fifth for trackless Slim-
- Line telescopic doors.
- a. Emergency Egress: Non-adjustable magnetic latch
- on SX panels and emergency breakaway release on
- SO panels, allowing 90 degree swing of both
- panels under minimum pressure from any position
- in SX panel cycle.
- b. Emergency Egress: Spring-loaded stainless steel
- ball detent latch on SO and SX panels, allowing
- 90 degree swing of both panels under minimum
- pressure from any position in SX panel cycle.
- c. Emergency Egress: Flush bolt in SO panel
- releasable after SX panel is in full open
- position past aluminum stop bar, allowing 90
- degree swing of both panels as a single unit
- under field-adjustable pressure.
- d. Emergency Egress: Spring-loaded stainless steel
- ball detent latch on SO and SX panels, allowing
- 90 degree swing of both panels under minimum
- pressure from any position in SX panel cycle.
- e. Emergency Egress: Spring-loaded stainless steel
- ball detent latch on SX panel(s), allowing 90
- degree swing of SX panel(s) under minimum
- pressure from any position in panel cycle.
- NOTE ** Delete all but one of the following five finish
- paragraphs. Dark bronze and natural anodizing are
- standard options -- all other finishes are extra.
- 13. Finish: Dark bronze anodized.
- 14. Finish: Natural aluminum anodized.
- 15. Finish: Black anodized.
- 16. Finish: Kynar 500(tm) coating; color: _____________.
- 17. Finish: Clad, ______________.
- NOTE ** Delete the following paragraph if only trackless
- doors are required.
-
- B. Track: Recessed in floor.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Verify that door openings are plumb, square, and ready
- for installation of ICU/CCU sliding doors.
- NOTE ** Delete the following paragraph for trackless
- installations.
-
- B. Verify that concrete is properly prepared to receive
- recessed floor track.
-
- 3.2 INSTALLATION
-
- A. Install ICU/CCU sliding doors, frames, hardware, and
- accessories in accordance with manufacturer's
- instructions.
- NOTE ** Delete the following paragraph for Slim-Line
- trackless installations.
-
- B. Install floor track in accordance with manufacturer's
- instructions.
-
- 3.3 ADJUST AND CLEAN
-
- A. Adjust doors for proper operation, without binding or
- scraping and without excessive noise.
-
-
- END OF SECTION
-