- SECTION 08110
-
- STEEL DOORS AND FRAMES
- NOTE ** This section is based on products manufactured by
- members of the Steel Door Institute, which is
- located at the following address:
- NOTE ** 30200 Detroit Road
- NOTE ** Cleveland, Ohio 44145
- NOTE ** Telephone 216-899-0010
- NOTE ** Fax 216-892-1404
- NOTE **
- NOTE ** Steel doors and frames that are manufactured
- without deviation from SDI standards offer economy
- of fabrication and compliance with recognized
- standards of quality. Non-standard units can
- result in added cost and lead time.
- NOTE **
- NOTE ** Members of the Steel Door Institute manufacture
- standard steel doors and frames in accordance with
- these standards. Standard-duty, heavy-duty, and
- extra-heavy-duty classifications in flush,
- seamless, glazed, louvered, and other styles are
- available.
- NOTE **
- NOTE ** SECTION 08110 - STEEL DOORS AND FRAMES, Copyright
- 1996, The Architect's Catalog, Inc.
-
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Delete items below not required for project.
-
- A. Steel doors.
-
- B. Steel frames.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 08210 - Wood Doors.
-
- B. Section 08220 - Plastic Doors.
-
- C. Section 08710 - Door Hardware.
-
- D. Section 08800 - Glazing.
-
- E. Section 09900 - Paints and Coatings.
-
- F. Section 13095 - X-Ray Radiation Protection.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section.
-
- A. ANSI/SDI 100-91 - Recommended Specifications for Standard
- Steel Doors & Frames; Steel Door Institute.
-
- B. SDI 105 - Recommended Erection Instructions for Steel
- frames.
-
- C. SDI 111 - Recommended Standard Details for Steel Doors &
- Frames.
-
- D. SDI 113 - Test Procedure and Acceptance Criteria for
- Acoustical Performance for Steel Door and Frame
- Assemblies.
-
- E. ASTM A 366/A 366M - Standard Specification for Steel,
- Sheet, Carbon, Cold-Rolled, Commercial Quality.
-
- F. ASTM A 568/A 568M - Standard Specification for Steel,
- Sheet, Carbon, and High-Strength, Low-Alloy, Hot-Rolled
- and Cold-Rolled, General Requirements For.
-
- G. ASTM A 569/A 569M - Standard Specification for Steel,
- Carbon (0.15 Maximum, Percent), Hot-Rolled Sheet and
- Strip Commercial Quality.
-
- H. ASTM A 591/A 591M - Standard Specification for Steel
- Sheet, Electrolytic Zinc-Coated, for Light Coating Mass
- Applications.
-
- I. ASTM A 653/A 653M - Standard Specification for Steel
- Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated
- (Galvannealed) by the Hot-Dip Process.
-
- J. ASTM A 924/A 924M - Standard Specification for General
- Requirements for Sheet Steel, Metallic-Coated by the Hot-
- Dip Process.
-
- K. NFPA 80 - Standard for Fire Doors and Windows.
-
- L. Building Materials Directory; Underwriters Laboratories
- Inc.
-
- M. Certification Listings; Warnock Hersey International
- Inc.
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Provide manufacturer's standard details
- and catalog data demonstrating compliance with referenced
- standards. Provide installation instructions.
-
- C. Certificates:
- 1. Provide manufacturer's certification that products
- comply with referenced standards.
- 2. Provide evidence of manufacturer's membership in the
- Steel Door Institute.
-
- D. Shop Drawings: Submit for approval the following:
- 1. Door, frame, and hardware schedule in accordance with
- SDI 111D.
- NOTE ** Delete the following paragraph if no factory-
- finished units are required.
-
- E. Samples: Submit for approval the following:
- 1. 6 x 6 inch samples of each color of factory finish
- specified.
-
- 1.5 QUALITY ASSURANCE
-
- A. Manufacturer Qualifications: Provide all products from a
- single manufacturer who is a member of the Steel Door
- Institute.
-
- 1.6 DELIVERY, STORAGE, AND HANDLING
-
- A. Protect products from moisture, construction traffic, and
- damage.
- 1. Store under cover.
- 2. Place units on 4-inch high wood sills or in a manner
- that will prevent rust or damage.
- 3. Do not use non-vented plastic or canvas shelters.
- 4. Should wrappers become wet, remove immediately.
- 5. Provide 1/4-inch space between doors to promote air
- circulation.
-
-
- PART 2 PRODUCTS
-
- 2.1 MATERIALS
-
- A. Steel Sheet for Doors and Frames:
- 1. Cold rolled steel: ASTM A 366 and A 568.
- 2. Hot rolled, pickled, and oiled steel: ASTM A 569 and
- A 568.
- NOTE ** Delete the following 2 paragraphs if galvanized
- units are not required.
- 3. Hot dipped zinc coated steel: ASTM A 924 and A 653;
- Class A40 for alloyed coatings or G60 for spangled
- coatings, minimum.
-
- B. Steel Sheet for Anchors and Accessories:
- 1. Electrolytically deposited zinc coated steel: ASTM A
- 591 and A 568; Class B (0.075 oz/sf), minimum.
-
- 2.2 MANUFACTURED UNITS
-
- A. Comply with SDI 100.
- NOTE ** Delete the following paragraph if fire-rated
- openings are not required.
-
- B. Fire-rated openings: Comply with NFPA 80.
- 1. Affix permanent labels attesting to fire resistance.
- 2. At stairway enclosures, provide units listed for 450
- degree F maximum temperature rise rating for 30
- minutes of exposure.
- NOTE ** Delete the following paragraph if no oversized
- openings are required. (Oversized openings are
- units that are larger than commonly fabricated for
- a given fire rating.) If oversized units are
- required, and if acceptable to the local authority
- having jurisdiction, retain the following
- paragraph.
- 3. Provide manufacturer's certificate that oversized
- openings have been constructed in accordance with all
- other applicable requirements for labeled door
- construction.
- NOTE ** Delete the first paragraph below if Grade and Model
- will be specified.
- NOTE **
- NOTE ** Delete the second paragraph if Grade and Model will
- be in the door schedule. If the second paragraph
- is retained, edit to suit project conditions;
- specify location of each required Grade and Model
- in the blanks provided.
- NOTE **
- NOTE ** Grade I and III frames are offered in 2 gages.
- Delete inapplicable gages.
- NOTE ** Grade II frames are offered in 16 gage, only.
- NOTE **
- NOTE ** For additional guidance, see SDI-108 Recommended
- Selection & Usage Guide for Standard Steel Doors.
-
- C. Provide Grade and Model as indicated in the Door
- Schedule.
-
- D. Provide Grade and Model as follows:
- 1. ____: Grade I, Model 1 (standard-duty, full flush
- design).
- a. Frames: 18 gage.
- b. Frames: 16 gage.
- 2. ____: Grade I, Model 2 (standard-duty, seamless
- design).
- a. Frames: 18 gage.
- b. Frames: 16 gage.
- 3. ____: Grade II, Model 1 (heavy-duty, full flush
- design).
- 4. ____: Grade II, Model 2 (heavy-duty, seamless
- design).
- 5. ____: Grade III, Model 1 (extra heavy-duty, full
- flush design).
- a. Frames: 16 gage.
- b. Frames: 14 gage.
- 6. ____: Grade III, Model 1A (extra heavy-duty, full
- flush design).
- a. Frames: 14 gage.
- b. Frames: 12 gage.
- 7. ____: Grade III, Model 2 (extra heavy-duty, seamless
- design).
- 8. ____: Grade III, Model 2A (extra heavy-duty,
- seamless design).
- a. Frames: 14 gage.
- b. Frames: 12 gage.
- 9. ____: Grade III, Model 3 (extra heavy-duty, stile
- and rail - flush panel design).
- a. Frames: 16 gage.
- b. Frames: 14 gage.
- 10. Wood or plastic doors specified elsewhere: Provide
- 18 gage, Grade I steel frames.
- 11. Wood or plastic doors specified elsewhere: Provide
- 16 gage, Grade I steel frames.
- 12. Wood or plastic doors specified elsewhere: Provide
- Grade II steel frames.
- 13. Wood or plastic doors specified elsewhere: Provide
- 16 gage, Grade III steel frames.
- 14. Wood or plastic doors specified elsewhere: Provide
- 14 gage, Grade III steel frames.
- NOTE ** Delete 1 of the 2 following paragraphs if
- galvanized frames are required. Delete both if
- none are required. If the second is retained, edit
- to suit project requirements.
-
- E. Provide units of galvanized steel where indicated on the
- door schedule.
-
- F. Provide units of galvanized steel in the following
- locations:
- 1. Exterior openings.
- 2. Kitchens.
- 3. Toilets.
- 4. Washrooms.
- 5. Locker rooms.
- 6. Showers.
- 7. Laboratories.
- NOTE ** Delete the following paragraph if no lights in
- doors, nor borrowed or side lights are required.
-
- G. Provide glazing stops and beads where glazed lights are
- indicated.
-
- 2.3 DOORS
-
- A. Construct doors in accordance with SDI 100.
- NOTE ** Delete the following paragraph if exterior doors
- are not required.
- NOTE **
- NOTE ** If retained, delete 2 of the 3 subparagraphs to
- indicate U-value, or edit to suit project
- requirements.
-
- B. Exterior doors:
- 1. Provide insulated construction with U-value of at
- least 0.48 when tested in accordance with SDI 113.
- 2. Provide manufacturer's standard foam insulated core.
- 3. Steel stiffened grid core and stile and rail units
- are exempt from thermal rating requirements.
- NOTE ** SDI-100 allows any core construction complying with
- established physical endurance test criteria.
- Therefore, unless unusual project conditions
- necessitate the specification of core construction,
- the following paragraph may be deleted in its
- entirety.
- NOTE **
- NOTE ** If retained, edit to suit project requirements.
-
- C. Construct full flush and seamless door cores as follows:
- 1. Fire-rated doors: In accordance with listed
- construction.
- 2. Honeycomb core.
- 3. Polyurethane foam core.
- 4. Polystyrene foam core.
- 5. Unitized grid core.
- 6. Steel stiffeners core.
- NOTE ** Delete the following paragraph if louvers are not
- required.
-
- D. Provide inserted louvers in accordance with SDI 111C
- where indicated. Type:
- 1. Inverted "V" blade.
- 2. "Z" blade.
- 3. Inverted "Y" blade.
- 4. Light proof.
- 5. Adjustable.
- 6. Fusible link.
- 7. Grille.
-
- 2.4 FRAMES
- NOTE ** Delete 1 of the 2 following paragraphs.
-
- A. Provide either knockdown field assembled or welded unit
- type frames unless otherwise indicated.
-
- B. Provide welded unit type frames.
- NOTE ** Delete any of the next 3 paragraphs if such units
- are not required.
-
- C. Provide drywall slip-on type frames for installation
- after drywall partition are erected
-
- D. Lights and Transoms: Provide tubular mullions and
- transom bars with heads and jambs.
-
- E. Terminate stops at a 45 degree angle, 6 inches above
- floor; cover stop with welded metal filler plate.
- 1. Exception: Light-proof doors, sound-rated, doors,
- lead-lined doors, and double egress doors.
- NOTE ** SDI-100 requires factory priming for field painting
- as a minimum. Many manufacturers also offer
- factory finishing.
- NOTE **
- NOTE ** Delete the following article if factory finished
- units are not required.
- NOTE **
- NOTE ** If retained, edit to indicate color.
-
- 2.5 FINISHES
-
- A. Provide factory-finished units.
- 1. Color: As indicated on the color schedule.
- 2. Color: _______.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. The installer shall verify that project conditions are
- suitable before beginning installation of frames.
- 1. Verify that completed openings to receive knock-down
- wrap-around frames are of correct size and thickness.
- 2. Verify that completed concrete or masonry openings to
- receive butt type frames are of correct size.
-
- B. Correct unsatisfactory condition before preceding with
- installation.
-
- 3.2 INSTALLATION
-
- A. Install frames in accordance with SDI 105.
-
- B. Install doors plumb and in true alignment and fasten to
- achieve the maximum operational effectiveness and
- appearance of the unit. Maintain clearances specified in
- SDI 100 or NFPA 80.
- NOTE ** Delete any of the 3 following paragraphs if not
- applicable.
-
- C. Fill welded wrap-around frames in masonry construction
- with mortar as masonry is laid-up.
-
- D. Fill welded wrap-around frames in plaster construction
- with plaster as work progresses.
-
- E. If additives are used in masonry or plaster work during
- cold weather, field coat the inside of steel frames with
- a bituminous compound to prevent corrosion.
-
- 3.3 ADJUST AND CLEAN
-
- A. Adjust doors for proper operation, free from binding or
- other defects.
-
- B. Clean and restore soiled surfaces. Remove scraps and
- debris, and leave site and a clean condition.
-
-
- END OF SECTION
-