home *** CD-ROM | disk | FTP | other *** search
- SECTION 05731
-
- ORNAMENTAL ALUMINUM COLUMNS
- NOTE ** Moultrie Manufacturing Company ornamental aluminum
- columns.
- NOTE **
- NOTE ** This section is based on products manufactured by
- Moultrie Manufacturing Company, located at the
- following address:
- NOTE ** Moultrie GA 31768
- NOTE ** Tel: (800) 841-8674
- NOTE **
- NOTE ** Moultrie Manufacturing Company offers a complete
- line of ornamental aluminum columns, as well as
- ornamental metal railing systems.
- NOTE **
- NOTE ** SECTION 05731 - ORNAMENTAL ALUMINUM COLUMNS,
- Copyright 1997, The Architect's Catalog, Inc.
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
-
- A. Aluminum Columns.
-
- B. Aluminum Column Capitals.
-
- C. Aluminum Column Bases.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 05120 - Structural Steel.
-
- B. Section 05500 - Metal Fabrications.
-
- C. Section 06100 - Rough Carpentry.
-
- D. Section 06400 - Architectural Woodwork.
-
- E. Section 09900 - Paints and Coatings.
-
- 1.3 REFERENCES
-
- A. ASTM B 179 - Standard Specification for Aluminum Alloys
- in Ingot Form for Castings from All Casting Processes.
-
- B. ASTM B 221 - Standard Specification for Aluminum and
- Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
- Tubes.
-
- C. ASTM B 221M - Standard Specification for Aluminum and
- Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
- Tubes (Metric).
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Manufacturer's descriptive literature for
- specified components; indicate compliance to specified
- requirements.
-
- C. Shop Drawings: Indicate locations, sizes, and heights of
- columns; include construction and installation details,
- and interface with adjacent construction.
- NOTE ** Delete the following two paragraphs if specifying
- primer-finished items.
-
- D. Verification Samples:
- 1. One (1) column section, minimum size 12 inches (300
- mm) long by diameter of specified column, with
- specified capital and base, representing actual color
- and finish of products to be installed.
- NOTE ** Retain one of the following three sub-paragraphs.
- 2. Return samples of capital and base to manufacturer
- when so directed by Architect, or at project
- closeout.
- 3. Accepted samples of capital and base may be
- incorporated into Work as last units of type.
- 4. Samples will be retained by Architect.
-
- E. Quality Assurance Submittals:
- 1. Design Data: Loading calculations for columns,
- bearing seal and signature of structural engineer
- licensed to practice in the State in which the
- project is located.
- 2. Certificates:
- a. Contractor's certification that installer meets
- specified qualifications.
- b. Manufacturer's certification that installer is
- approved.
- 3. Manufacturer's Instructions: Printed installation
- instructions for each product, including product
- storage requirements and instructions for bracing and
- shoring of adjacent construction.
-
- 1.5 QUALITY ASSURANCE
-
- A. Installer Qualifications: Minimum three (3) years
- documented experience installing products specified in
- this section, and approved by manufacturer.
-
- 1.6 DELIVERY, STORAGE, AND HANDLING
-
- A. Store products of this section in manufacturer's unopened
- packaging until installation.
-
- B. Maintain storage area conditions for products of this
- section in accordance with manufacturer's instructions
- until installation.
-
- 1.7 PROJECT CONDITIONS
-
- A. Field Measurements: When construction schedule permits,
- take field measurements at locations where columns are to
- be installed prior to ordering components.
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: Moultrie Manufacturing Company,
- Moultrie GA 31768. ASD. Telephone (800) 841-8674.
- NOTE ** Delete one of the two following paragraphs;
- coordinate with Division 1 requirements.
-
- B. Requests for substitution will be considered in
- accordance with provisions of Section 01600.
-
- C. Substitutions: Not permitted.
- NOTE ** Delete following paragraph if substitutions not
- permitted.
-
- D. Unless otherwise specified for an individual product or
- material, supply all products specified in this section
- from the same manufacturer.
-
- 2.2 COMPONENTS
- NOTE ** Retain the following paragraph to specify square
- columns; if more than one type, size, or finish is
- required, assign a type to each, duplicate
- paragraph and edit for each. Coordinate types with
- drawings.
-
- A. Square Column Assemblies:
- 1. Column: Fabricated staves of extruded aluminum
- conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
- Temper T6; with snap-fitting vertical seams for field
- assembly:
- NOTE ** Retain one of the following four sub-paragraphs to
- specify square column style.
- a. Style: Old South Traditional Square Column,
- fluted vertical faces.
- b. Style: Old South Federal Square Column, flat
- vertical faces.
- c. Style: Old South Square Plantation Column,
- single-indent vertical faces.
- d. Style: Old South Square Plantation Column,
- double-indent vertical faces.
- NOTE ** Retain one of the following six sub-paragraphs to
- specify size and load-bearing capacity of column.
- e. Size: 3 inches ( 76 mm) square; 10,000 pounds (
- 4,530 kg) load-bearing capacity.
- f. Size: 4 inches (101 mm) square; 15,000 pounds (
- 6,795 kg) load-bearing capacity.
- NOTE ** The above sizes available for Traditional Square
- Column only.
- g. Size: 6 inches (152 mm) square; 22,000 pounds (
- 9,966 kg) load-bearing capacity.
- h. Size: 8 inches (203 mm) square; 30,000 pounds
- (13,590 kg) load-bearing capacity.
- i. Size: 10 inches (254 mm) square; 30,000 pounds
- (13,590 kg) load-bearing capacity.
- j. Size: 12 inches (305 mm) square; 30,000 pounds
- (13,590 kg) load-bearing capacity.
- NOTE ** Retain one of the following two sub-paragraphs to
- specify column length.
- k. Column length: __ feet __ inches (__ m).
- l. Column length: Indicated on drawings.
-
- 2. Capital and base: Cast of aluminum conforming to
- ASTM B 179; size for slip-fit over column:
- NOTE ** Retain one of the following three sub-paragraphs to
- specify capital for square columns.
- a. Capital: Standard square.
- b. Capital: Architectural square.
- c. Capital: Architectural II square.
- NOTE ** Retain one of the following three sub-paragraphs to
- specify base for square columns.
- d. Base: Standard square.
- e. Base: Architectural square.
- f. Base: Architectural II square.
- NOTE ** Retain one of the following six sub-paragraphs to
- specify column, capital, and base finish.
- 3. Finish: Factory primer.
- 4. Finish: Factory baked-on powder coat enamel, White
- color.
- 5. Finish: Factory baked-on powder coat enamel,
- Alabaster color.
- 6. Finish: Factory baked-on powder coat enamel, Biscuit
- color.
- 7. Finish: Factory baked-on powder coat enamel, Clay
- color.
- 8. Finish: Factory baked-on powder coat enamel, Brown
- color.
- NOTE ** Retain the following paragraph to specify round
- columns.
-
- B. Round Column Assemblies:
- 1. Column: Fabricated staves of extruded aluminum
- conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
- Temper T6; with snap-fitting vertical seams for field
- assembly:
- a. Style: Old South Round Column, fluted vertical
- faces.
- NOTE ** Retain one of the following nine sub-paragraphs to
- specify size and load-bearing capacity of column.
- b. Size: 5 inches (127 mm) diameter; 16,000 pounds
- ( 7,248 kg) load-bearing capacity.
- c. Size: 6 inches (152 mm) diameter; 22,000 pounds
- ( 9,966 kg) load-bearing capacity.
- d. Size: 8 inches (203 mm) diameter; 29,000 pounds
- (13,137 kg) load-bearing capacity.
- e. Size: 10 inches (254 mm) diameter; 21,000 pounds
- ( 9,513 kg) load-bearing capacity.
- f. Size: 12 inches (305 mm) diameter; 28,000 pounds
- (12,684 kg) load-bearing capacity.
- g. Size: 15 inches (381 mm) diameter; 31,000 pounds
- (14,043 kg) load-bearing capacity.
- h. Size: 18 inches (457 mm) diameter; 31,000 pounds
- (14,043 kg) load-bearing capacity.
- i. Size: 24 inches (609 mm) diameter; 31,000 pounds
- (14,043 kg) load-bearing capacity.
- NOTE ** Consult with manufacturer for data for 36-inch
- diameter column.
- j. Size: 36 inches (914 mm) diameter; __,___ pounds
- (__,___ kg) load-bearing capacity.
- NOTE ** Retain one of the following two sub-paragraphs to
- specify column length.
- k. Column length: __ feet __ inches (__ m).
- l. Column length: Indicated on drawings.
- 2. Capital and base: Cast of aluminum conforming to
- ASTM B 179; size for slip-fit over column:
- NOTE ** Retain one of the following four sub-paragraphs to
- specify capital for round columns.
- a. Capital: Standard round.
- b. Capital: Doric round.
- c. Capital: Corinthian round.
- d. Capital: Scamozzi round.
- NOTE ** Retain one of the following two sub-paragraphs to
- specify base for round columns.
- e. Base: Standard round.
- f. Base: Doric round.
- NOTE ** Retain one of the following six sub-paragraphs to
- specify column, capital, and base finish.
- 3. Finish: Factory primer.
- 4. Finish: Factory baked-on powder coat enamel, White
- color.
- 5. Finish: Factory baked-on powder coat enamel,
- Alabaster color.
- 6. Finish: Factory baked-on powder coat enamel, Biscuit
- color.
- 7. Finish: Factory baked-on powder coat enamel, Clay
- color.
- 8. Finish: Factory baked-on powder coat enamel, Brown
- color.
- NOTE ** Delete the following paragraph if not required for
- project.
-
- C. As indicated on shop drawings, provide column sections,
- capital, and base fabricated in split components for
- retro-fit installation; provide for concealed fastening
- of split component halves.
-
- D. Accessories: Provide accessories specified in
- manufacturer's instructions or indicated on shop
- drawings, including, but not limited to, lally columns,
- load distribution plates, angle clips, and fasteners.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Verify that heights of locations to receive columns are
- in accordance with shop drawings.
-
- B. Installer's Examination:
- 1. Have installer of this section examine conditions
- under which construction activities of this section
- are to be performed, then submit written notification
- if such conditions are unacceptable.
- 2. Transmit two copies of installer's report to
- Architect within 24 hours of receipt.
- 3. Beginning construction activities of this section
- before unacceptable conditions have been corrected is
- prohibited.
- 4. Beginning construction activities of this section
- indicates installer's acceptance of conditions.
-
- 3.2 PREPARATION
-
- A. Shore and brace adjacent construction in accordance with
- manufacturer's instructions.
-
- 3.3 INSTALLATION
-
- A. Install components in accordance with shop drawings and
- manufacturer's installation instructions.
-
- B. Remove shoring and bracing immediately after completion
- of column installation.
-
- C. Site Tolerances:
- 1. Maximum variation from indicated location: 1/4 inch
- (6 mm).
- 2. Maximum variation from plumb: 1/4 inch (6 mm) in 10
- feet (3 m).
- NOTE ** Delete the following paragraph if components are
- factory finished.
-
- D. Field Finishing: Specified in Section 09900.
-
- 3.4 CLEANING
-
- A. Clean component finishes in accordance with
- manufacturer's instructions immediately after
- installation; protect finishes from soiling until
- Substantial Completion.
-
- 3.5 PROTECTION
-
- A. Protect components and component finishes from damage by
- subsequent construction activities until Substantial
- Completion.
-
- B. Repair damage in accordance with manufacturer's
- recommendations; replace units which cannot be repaired
- to Architect's acceptance.
-
-
- END OF SECTION
-