  1. 1    PDQTapi Control
  2. 2    PDQTapi Property Page
  3. 3    You are not licensed to use the PDQTapi control in a development environment.\n Please contact Crescent at 781-280-3000 for information on obtaining a license.
  4. 100    General
  5. 1000    TAPI is busy.
  6. 1001    The varControl parameter is not PDQComm or an older version that does not support TAPI.
  7. 1002    The selected device can not place a call.
  8. 1003    The varControl parameter is not an OLE control.
  9. 1004    Unspecified OLE Automation error.
  10. 1005    The varControl parameter does not contain an AddItem method.
  11. 2001    The line cannot be opened due to a "persistent" condition, such as that of a serial port being exclusively opened by another process.
  12. 2002    The specified device ID or line device ID (such as in a dwDeviceID parameter) is invalid or out of range.
  13. 2003    The call's bearer mode cannot be changed to the specified bearer mode. 
  14. 2004    Unspecified TAPI error
  15. 2005    All call appearances on the specified address are currently in use.
  16. 2006    The maximum number of outstanding call completions has been exceeded.
  17. 2007    The maximum number of parties for a conference has been reached, or the requested number of parties cannot be satisfied.
  18. 2008    The dialable address parameter contains dialing control characters that are not processed by the service provider.
  19. 2009    The dialable address parameter contains dialing control characters that are not processed by the service provider.
  20. 2010    The dialable address parameter contains dialing control characters that are not processed by the service provider.
  21. 2011    The dialable address parameter contains dialing control characters that are not processed by the service provider.
  22. 2012    The application requested an API version or version range that is either incompatible or cannot be supported by the Telephony API implementation and/or corresponding service provider.
  23. 2013    The application requested an extension version range that is either invalid or cannot be supported by the corresponding service provider.
  24. 2014    The file TELEPHON.INI cannot be read or understood properly by TAPI.DLL because of internal inconsistencies or formatting problems. For example, the [Locations], [Cards], or [Countries] section of TELEPHON.INI may be corrupted or inconsistent.
  25. 2015    The line device is in use and cannot currently be configured, allow a party to be added, allow a call to be answered, allow a call to be placed, or allow a call to be transferred.
  26. 2016    A specified address is either invalid or not allowed. If invalid, the address contains invalid characters or digits, or the deistination address contains dialing control characters (W, @, $, or ?) that are not supported by the service provider. If not allowed, the specified address is either not assigned to the specified line or is not valid for address redirection.
  27. 2017    The specified address ID is either invalid or out of range.
  28. 2018    The specified address mode is invalid.
  29. 2019    dwAddressStates contains one or more bits that are not LINEADDRESSSTATE_ constants.
  30. 2020    The application handle (such as specified by a hLineApp parameter) or the appliction registration handle is invalid.
  31. 2021    The specified application name is invalid. If an application name is specified by the application, it is assumed that the string does not contain any non-displayable characters, and is zero-terminated.
  32. 2022    The specified bearer mode is invalid.
  33. 2023    The specified completion is invalid.
  34. 2024    No TAPI error string.
  35. 10000    The strAddress parameter can not be null.
  36. 10001    Unable to translate the strAddress parameter into a dialable address.
  37. 10002    Out of memory.
  38. 20000    8878B000-75A8-11CF-B3F7-00AA00B77521
  39. 20001    1C03CB80-75A8-11CF-98D5-0080C7116908
  40. 20002    77B00F80-75D3-11CF-87F3-0080C7973784
  41. 20003    0E5666E0-75A9-11CF-A308-0020AFA5C82F
  42. 20004    FFE11E60-75A9-11CF-A123-0020AF299573
  43. 20010    Licensed for full functionality
  44. 20011    Licensed for design time use only
  45. 20012    Licensed for full functionality (Internet ToolPak license)
  46. 20015    This application was created with a PDQComm\nTest Drive. You are only licensed\nto use these controls in the VB environment.\n\nTo purchase a full product license, go to\nCode Depot at http://crescent.progress.com.