  3. AST RESEARCH, INC.         TECHNICAL BULLETIN #0769A                 11-10-92
  4.  
  5. =============================================================================
  6.  
  7.  
  8.                      AST SVGA 14" LOW RADIATION MONITOR
  9.  
  10.  
  11. PROBLEM:       When using the 1024x768 mode on the SVGA 14" low radiation
  12.                monitor, the picture will shift to the left.
  13.  
  14. CAUSE:         This is due to a timing issue within the monitor itself.
  15.  
  16. AFFECTED
  17. SYSTEMS:       SVGA 14" low radiation monitor part number  500902-XXX
  18.                revision A.
  19.  
  20. SOLUTION:      Replace revision A monitor with a revision B monitor part
  21.                number 500902-001, 002, or 003.
  22.  
  23. NOTE:  The part number 500902-XXX on the packing box will remain revision A.
  24.        However, the part number on the monitor itself will change to 230253-