  1. =============================================================================
  2.  
  3. AST RESEARCH, INC.         TECHNICAL BULLETIN #0750                  04-01-92
  4.  
  5. =============================================================================
  6.  
  7.  
  8.                    PREMIUM EXEC NI-CAD BATTERY INFORMATION
  9.  
  10.  
  11. PROBLEM:       All Nickel-Cadmium (Ni-Cad) rechargeable batteries have the
  12.                inherent "memory" property that can cause early low voltage
  13.                indications and premature system shutdown.
  14.  
  15. CAUSE:         When a Ni-Cad battery is put through repeated partial-
  16.                discharge / recharge cycles, and is drained to approximately
  17.                the same level each time - down to half capacity, for example
  18.                - it develops a "memory" of this point in the discharge
  19.                process.  Once established, Ni-Cad memory distorts the
  20.                battery's voltage output profile.  The battery will produce a
  21.                normal voltage until drained to the memorized location, but
  22.                thereafter its voltage output abruptly sags to a sub-normal
  23.                value, and stays below normal until actual battery depletion.
  24.                The voltage depression can be deep enough to cause the
  25.                Notebook to prematurely issue the low battery warning (audible
  26.                beep and lighted amber LED) or battery fail warning (audible
  27.                beep and blinking amber LED.)
  28.  
  29. SOLUTION:      The Ni-Cad battery "memory" effect can be corrected by
  30.                "conditioning" the battery, a process which simply consists of
  31.                fully discharging the battery before recharging.
  32.  
  33.                The battery pack should never be disturbed while the system is
  34.                in use or while the battery is being charged.  To remove or
  35.                install a battery, the system should be powered down and the
  36.                AC adapter removed.
  37.  
  38.                AST recommends conditioning the battery pack monthly to
  39.                promote optimum performance.  Conditioning of new, out-of-the-
  40.                box Ni-Cad battery pack is also strongly recommended. Listed
  41.                below are the steps required to correctly condition the
  42.                Premium Exec Ni-Cad battery:
  43.  
  44.                1. Charge the Ni-Cad battery up to full capacity.
  45.  
  46.                2. Disconnect the AC adapter.
  47.  
  48.                3. Configure the Notebook's Setup Menu as shown below.
  49.  
  50. IMPORTANT:     Note that Suspend must be ENABLED!
  51.  
  52.                Default Speed:       HIGH
  53.                Backlight Timeout:   0
  54.                Hard Disk Timeout:   0
  55.                Suspend:             ENABLE
  56.                Software Timeout:    0
  57.                (Exec SX-25 and
  58.                SX-25 color only)
  59.                Turbo Mode:          ON AT BOOT
  60.                Speaker:             ENABLE
  61.                Other Parameters:    Don't care
  62.  
  63. This configuration results in a near-maximum load on the battery during the
  64. first part of the conditioning process. Suspend mode then prevents an
  65. excessive drain rate as the battery nears depletion.
  66.  
  67.                4. Store  the setup  menu setting  and exit.   The system will
  68.                   reboot and the screen will display the DOS prompt.
  69.  
  70.                5. Keep  the Notebook powered up with its LCD display open for
  71.                   12 TO 24 HOURS.
  72.  
  73. Most will find that overnight conditioning of the battery is the most
  74. convenient method.
  75.  
  76. It is safe to use the Notebook in the normal fashion during the conditioning
  77. process.  However, the following precautions must be observed:
  78.  
  79.                   a. Save your work and exit all applications back to the DOS
  80.                      prompt immediately after the first low battery warning.
  81.                      Allow the Notebook to remain powered up with the LCD
  82.                      display open, however.
  83.  
  84.                   b. A full 12 hours of on-time will insure complete battery
  85.                      discharge even with premature suspend activation caused
  86.                      by the "memory" effect.
  87.  
  88.                6. After 12 hours, turn the Notebook off.  Recharge the
  89.                   battery by attaching the AC adapter.  Connect the AC
  90.                   adapter to the Notebook before plugging the adapter into
  91.                   the AC socket.  Connecting the AC adapter in this sequence
  92.                   insures that the Notebook battery management system senses
  93.                   all signals on the DIN connector appropriately.
  94.  
  95. NOTE:  After completing a "fast discharge", wait at least 5 minutes before
  96. connecting the AC Adapter/Charger to recharge the battery.  If this is not