home *** CD-ROM | disk | FTP | other *** search
/ ftp.cvut.cz / DOS_LEGACY_DRIVERS_2008.zip / DOS_LEGACY_DRIVERS / eisa / !icu1240.cfg < prev    next >
Text File  |  2008-01-06  |  4KB  |  185 lines

  1. BOARD
  2.      ID = "ICU1240"
  3.      NAME = "Procomp USA, Incoprated S-DCB"
  4.      MFR = "Procomp USA, Incorporated"
  5.      VERSION = 1,0
  6.      CATEGORY = "MSD"
  7.      SLOT = ISA16
  8.      COMMENTS = "Procomp S-DCB\n"
  9.                  
  10. SWITCH(1) = 8
  11.      NAME = "Channel Select"
  12.      STYPE = DIP
  13.      LABEL = LOC(8-1) "SW1/8" "SW1/7" "SW1/6" "SW1/5" 
  14.                       "SW1/4" "SW1/3" "SW1/2" "SW1/1" 
  15.      FACTORY = LOC(8-1) 11001000
  16.  
  17. JUMPER(1) = 1
  18.      NAME = "TERMPWR to SCSI"
  19.      JTYPE = PAIRED
  20.      VERTICAL = NO
  21.      LABEL = LOC(1)  "1"
  22.      FACTORY = LOC(1) 1
  23.  
  24. JUMPER(4) = 1
  25.      NAME = "UPS battery Low contact position"
  26.      JTYPE = PAIRED
  27.      VERTICAL = NO
  28.      LABEL = LOC(1) "1"
  29.      FACTORY = LOC(1) 0
  30.  
  31. JUMPER(5) = 1
  32.      NAME = "UPS On-Line contact position"
  33.      JTYPE = PAIRED
  34.      VERTICAL = NO
  35.      LABEL = LOC(1) "1"
  36.      FACTORY = LOC(1) 0
  37.  
  38. FUNCTION = "BIOS Address"
  39.      CHOICE = "CC000"
  40.        FREE
  41.        MEMORY = 8K
  42.        ADDRESS = 0CC000H
  43.        WRITABLE = NO
  44.        MEMTYPE = OTH
  45.        SHARE = NO
  46.        INIT = SWITCH(1) LOC(5-7) 101
  47.      CHOICE = "DC000"
  48.        FREE
  49.        MEMORY = 8K
  50.        ADDRESS = 0DC000H
  51.        WRITABLE = NO
  52.        MEMTYPE = OTH
  53.        SHARE = NO
  54.        INIT = SWITCH(1) LOC(5-7) 000
  55.      CHOICE = "DA000"
  56.        FREE
  57.        MEMORY = 8K
  58.        ADDRESS = 0DA000H
  59.        WRITABLE = NO
  60.        MEMTYPE = OTH
  61.        SHARE = NO
  62.        INIT = SWITCH(1) LOC(5-7) 010
  63.      CHOICE = "D8000"
  64.        FREE
  65.        MEMORY = 8K
  66.        ADDRESS = 0D8000H
  67.        WRITABLE = NO
  68.        MEMTYPE = OTH
  69.        SHARE = NO
  70.        INIT = SWITCH(1) LOC(5-7) 011
  71.      CHOICE = "CE000"
  72.        FREE
  73.        MEMORY = 8K
  74.        ADDRESS = 0CE000H
  75.        WRITABLE = NO
  76.        MEMTYPE = OTH
  77.        SHARE = NO
  78.        INIT = SWITCH(1) LOC(5-7) 100
  79.      CHOICE = "CA000"
  80.        FREE
  81.        MEMORY = 8K
  82.        ADDRESS = 0CA000H
  83.        WRITABLE = NO
  84.        MEMTYPE = OTH
  85.        SHARE = NO
  86.        INIT = SWITCH(1) LOC(5-7) 110
  87.      CHOICE = "C8000"
  88.        FREE
  89.        MEMORY = 8K
  90.        ADDRESS = 0C8000H
  91.        WRITABLE = NO
  92.        MEMTYPE = OTH
  93.        SHARE = NO
  94.        INIT = SWITCH(1) LOC(5-7) 111
  95.  
  96. FUNCTION = "Channel Select"
  97.      CHOICE = "CH:1,I/O:340,IRQ:11"
  98.        FREE
  99.        PORT = 0340H
  100.        FREE
  101.        IRQ = 11
  102.        SHARE = NO
  103.        INIT = SWITCH(1) LOC(1-3) 001
  104.      CHOICE = "CH:2,I/O:348,IRQ:12"
  105.        FREE
  106.        PORT = 0348H
  107.        FREE
  108.        IRQ = 12
  109.        SHARE = NO
  110.        INIT = SWITCH(1) LOC(1-3) 111
  111.      CHOICE = "CH:3,I/O:320,IRQ:10"
  112.        FREE
  113.        PORT = 0320H
  114.        FREE
  115.        IRQ = 10
  116.        SHARE = NO
  117.        INIT = SWITCH(1) LOC(1-3) 011
  118.      CHOICE = "CH:4,I/O:328,IRQ:15"
  119.        FREE
  120.        PORT = 0328H
  121.        FREE
  122.        IRQ = 15
  123.        SHARE = NO
  124.        INIT = SWITCH(1) LOC(1-3) 101
  125.      CHOICE = "CH:5,I/O:380,IRQ:10"
  126.        FREE
  127.        PORT = 0380H
  128.        FREE
  129.        IRQ = 10
  130.        SHARE = NO
  131.        INIT = SWITCH(1) LOC(1-3) 010
  132.      CHOICE = "CH:6,I/O:388,IRQ:15"
  133.        FREE
  134.        PORT = 0388H
  135.        FREE
  136.        IRQ = 15
  137.        SHARE = NO
  138.        INIT = SWITCH(1) LOC(1-3) 100
  139.      CHOICE = "Disabled"
  140.        DISABLE = YES
  141.        FREE
  142.        INIT = SWITCH(1) LOC(1-3) 110 | 000
  143.  
  144. FUNCTION = "Floppy Drive"
  145.    CHOICE = "Enabled"
  146.      FREE
  147.      INIT = SWITCH(1) LOC(7) 1
  148.    CHOICE = "Disabled"
  149.      DISABLE = YES
  150.      FREE
  151.      INIT = SWITCH(1) LOC(7) 0
  152.  
  153. FUNCTION = "SCSI Parity check"
  154.    CHOICE = "Enabled"
  155.       FREE
  156.       INIT = SWITCH(1) LOC(8) 1
  157.    CHOICE = "Disabled"
  158.       DISABLE = YES
  159.       FREE
  160.       INIT = SWITCH(1) LOC(8) 0
  161.  
  162. FUNCTION = "Term. Power to SCSI bus"
  163.    CHOICE = "Supplied"
  164.       FREE
  165.       INIT = JUMPER(1) LOC(1) 1
  166.    CHOICE = "Not Supplied"
  167.       FREE
  168.       INIT = JUMPER(1) LOC(1) 0
  169.       
  170. FUNCTION = "UPS Battery Low contact position"
  171.    CHOICE = "Open"
  172.       FREE
  173.       INIT = JUMPER(4) LOC(1) 0
  174.    CHOICE = "Closed"
  175.       FREE
  176.       INIT = JUMPER(4) LOC(1) 1
  177.  
  178. FUNCTION = "UPS On-line contact position"
  179.    CHOICE = "Open"
  180.       FREE
  181.       INIT = JUMPER(5) LOC(1) 0
  182.    CHOICE = "Closed"