home *** CD-ROM | disk | FTP | other *** search
/ High Voltage Shareware / high1.zip / high1 / DIR4 / RITM258A.ZIP / WHATSNEW.TXT < prev   
Text File  |  1993-08-26  |  4KB  |  72 lines

  1. RighTime v2.58a                                 Copyright 1991-93, GTBecker
  2. Released August 26, 1993                                All Rights Reserved
  3.  
  4.  
  5.                    What's new in RighTime Version 2.58a?
  6.  
  7. Version 2.58a corrects unpredictable DTR behavior on /Mport while in Microsoft
  8. Windows' 386 Enhanced mode.  This should have been included in v2.58, but
  9. wasn't.
  10.  
  11.      On a related matter: since DTR still can still contain short glitches
  12.      while multitasking in Windows 386 Enhanced mode, we suggest that you add
  13.      S25=100 to your modem's active profile.  This decreases the sensitivity
  14.      to changes on DTR.
  15.  
  16. Version 2.58 solves a long-standing difficulty with communications, provides
  17. automatic disabling of both 0.01 DOS clock resolution and learning when
  18. Windows in 386 Enhanced mode is resident, starts balky CMOS RTCs, and improves
  19. stability.
  20.  
  21.      Some machines experienced serial port errors, usually showing up as file
  22.      transfer resends or noisy faxes.  The trouble was long thought to be
  23.      something elusive in RighTime itself, but was finally located in the
  24.      BIOS interrupt handler.  Because of this, RighTime must be inoperative
  25.      during critical serial port use since it must use the interrupts that
  26.      are at the core of the errors.  Two new techniques are available in
  27.      v2.58 to determine serial port activity - one senses DCD (Carrier
  28.      Detect) differently than v2.53 and v2.54 did (/Mport), and a new method
  29.      senses IRQ activity (/MIport) - and a new dormant mode is automatically
  30.      controlled by them.
  31.  
  32.      Version 2.58 also uses a different process to start the CMOS RTC; some
  33.      machines refused to start properly, causing a failed selftest and
  34.      subsequent program load abort.
  35.  
  36.      If RighTime is running in its high resolution (0.01 second) mode, and
  37.      Windows is in 386 Enhanced mode, the clock in DOS sessions behaves
  38.      poorly.  This is due to the non-preemptive multitasking technique used
  39.      in Windows which cannot guarantee prompt interrupt response.  RighTime
  40.      v2.58 senses this condition and automatically disables high resolution
  41.      mode while Windows in 386 Enhanced mode is present, essentially an
  42.      automatic /TH.
  43.  
  44.      If the time is set from within Windows in 386 Enhanced mode, the time
  45.      will be set late and the resulting false error will improperly affect
  46.      the correction values.  By default, learning is now disabled for time
  47.      sets from within Windows 386 Enhanced mode, as well as the first set
  48.      that follows any such sets.  If the user insists, a switch (/LW) enables
  49.      learning under these conditions.  All other RighTime functions operate
  50.      normally, but the user is still cautioned to not trust that the time
  51.      indicated while in Windows 386 Enhanced mode is correct.  The Windows
  52.      clock is usually a second or two late without RighTime or less than one
  53.      second late with RighTime, and it does not increment smoothly.
  54.  
  55.      Several internal improvements have increased the timing stability; 
  56.      TestTime now usually shows measurement-to-measurement variations on the
  57.      order of tenths of milliseconds.  TestTime and TestIncr are improved and
  58.      RighTLog and SetupRT2 match RighTime's changes.
  59.  
  60. Version 2.54 added two new switches, /I"name" and /#.  These ease the handling
  61. of unexpected or unwanted date and time sets, and allow the system date and
  62. time to be protected from inadvertent or unauthorized changes.  Internal
  63. improvements were implemented to reduce DOS clock jitter to below one
  64. millisecond.
  65.  
  66. Version 2.53 was the first release since v1.1 (v2.00 to v2.52 either never
  67. left the shop or went only to beta testers over an 18-month development
  68. period).  From version 1.1, there were many improvements.  If you are a v1.1
  69. user, you'll need to read the document, RighTime.TXT, to catch up.
  70.  
  71. Changes in RighTime.TXT are indicated by asterisks on the left margin.
  72.