home *** CD-ROM | disk | FTP | other *** search
/ High Voltage Shareware / high1.zip / high1 / DIR13 / DOSUP8.ZIP / DOSUP8.TXT < prev    next >
Text File  |  1993-11-04  |  14KB  |  296 lines

  1.  
  2.               NOVELL TECHNICAL INFORMATION DOCUMENT
  3.  
  4. TITLE:              DOS Client Files Update Kit Number Eight
  5. DOCUMENT ID:        TID013923
  6. DOCUMENT REVISION:  A
  7. DATE:               27OCT93
  8. ALERT STATUS:       Yellow
  9. INFORMATION TYPE:   Symptom Solution
  10. README FOR:         DOSUP8.EXE
  11.  
  12. NOVELL PRODUCT and VERSION:
  13. NetWare Client for DOS/Windows
  14.  
  15. ABSTRACT:
  16.  
  17. Contains updated DOS client files.  This file includes NetWare shells v3.32
  18. (NETX.EXE, EMSNETX.EXE, XMSNETX.EXE), compatible with DOS 3.0 and above
  19. (including MS DOS 6.0), DR DOS 6.0 and Windows 3.0 and 3.1.  Support for both
  20. ODI and dedicated IPX are included as well as NETBIOS and other DOS client
  21. files.
  22.  
  23. ──────────────────────────────────────────────────────────────────────────────
  24. DISCLAIMER
  25. THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL.  NOVELL
  26. MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION.  HOWEVER, THE
  27. INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY.  NOVELL
  28. MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.
  29. ──────────────────────────────────────────────────────────────────────────────
  30.  
  31. SYMPTOM:
  32.  
  33.      When using LSL, IPXODI, and MLID drivers, several known anomalies occur.
  34.  
  35. SOLUTION:
  36.  
  37.      Copy the updated files to the appropriate directories, and reboot the
  38.      workstation.  Files marked with an "*" are new since DOSUP7.EXE.  Files
  39.      marked with a "^" have been updated since DOSUP7.EXE.
  40.  
  41.      Self-Extracting File Name:  DOSUP8.EXE     Revision:  A
  42.  
  43.      Files Included    Size      Date      Time     Version
  44.  
  45.      \
  46.        DOSUP8.TXT             (This File)
  47.           BSD.TXT      17466   11-03-93   11:17a             ^
  48.         DOSNP.EXE     10,547   07-19-93    3:17p       2.10  *
  49.      DOSODIWS.DOC       4916   11-03-93    2:19a             *
  50.       EMSNETX.EXE     90,430   06-24-93    2:18p    3.32ptf  ^
  51.       HISTORY.DOC      22041   11-04-93    8:46a
  52.         INT2F.COM        640   07-28-88   11:48a
  53.           IPX.OBJ     20,340   11-21-91   12:50p       3.10
  54.        IPXODI.COM     30,247   10-07-93    4:52p       2.12  ^
  55.        LANSUP.COM     21,943   02-02-93   11:54a       1.27
  56.           LSL.COM     17,805   09-10-93    3:50p       2.05  ^
  57.        NE1000.COM     19,807   07-30-93    9:40a       1.28  ^
  58.       NE1500T.COM     29,258   07-30-93    9:41a       1.27  ^
  59.           NE2.COM     20,192   07-30-93    9:36a       1.27  ^
  60.        NE2000.COM     21,188   07-30-93    9:38a       1.53  ^
  61.        NE2100.COM     29,256   07-30-93    9:41a       1.27  ^
  62.        NE2_32.COM     19,903   07-30-93    9:39a       1.30  ^
  63.        NE3200.COM     26,568   07-30-93    9:41a       1.17  ^
  64.       NETBIOS.EXE     24,392   06-22-93    4:09p       3.14  ^
  65.          NETX.EXE     78,606   06-24-93    2:18p    3.32ptf  ^
  66.       NTR2000.COM     24,909   03-31-93    9:46a       1.04  *
  67.       ODIINFO.DOC      24499   12-09-92    2:43p
  68.       ODINSUP.COM     33,867   02-23-93    8:58a
  69.       ODINSUP.DOC      42016   10-28-93    1:07a
  70.         PCN2L.COM     21,294   04-28-93    1:12p       1.41  ^
  71.         ROUTE.COM      4,882   05-11-93    8:59a       2.10  ^
  72.        RPLFIX.COM      1,746   09-30-91    9:39a       1.02
  73.        RPLFIX.DOC       2255   02-21-91    2:47p
  74.        RPLODI.COM      1,652   03-21-91    2:24p       1.02
  75.        TASKID.COM      7,539   01-22-93   10:47a       1.10  *
  76.         TBMI2.COM     24,884   06-03-93    4:36p       3.14  ^
  77.         TOKEN.COM     27,381   04-12-93    6:27p       1.27
  78.        TOKODI.DOC       6882   11-03-93    2:08a             *
  79.        TRXNET.COM     18,765   12-21-92    2:27p       1.35  ^
  80.       XMSNETX.EXE     87,094   06-24-93    2:19p    3.32ptf  ^
  81.  
  82.      Solution Specifics:
  83.  
  84.      This README file accompanies DOSUP8.EXE that comprises DOS client files
  85.      for NetWare 3.x, 2.1x and 2.2x operating systems.
  86.  
  87.      Brief description of the binary files included in the kit:
  88.  
  89.      FILE                DESCRIPTION
  90.  
  91.      DOSNP.EXE:          NetWare DOS NP Extender
  92.      EMSNETX.EXE:        NetWare EMS Workstation Shell
  93.      INT2F.COM:          Novell Network BIOS Interrupt 2Fh Emulator
  94.      IPX.OBJ:            Novell IPX/SPX
  95.                          (No further development is being done on IPX.OBJ. 
  96.                          Novell recommends  you use the ODI client software.
  97.                          See ODIINFO.DOC for details.)
  98.  
  99.      IPXODI.COM:         NetWare IPX/SPX Protocol
  100.      LANSUP.COM:         IBM LAN Support MLID
  101.      LSL.COM:            NetWare Link Support Layer
  102.      NE1000.COM:         Novell NE1000 Ethernet MLID
  103.      NE1500T.COM:        Novell NE1500T Ethernet MLID
  104.      NE2.COM:            Novell NE2 Ethernet MLID
  105.      NE2_32.COM:         Novell NE2-32 Ethernet MLID
  106.      NE2000.COM:         Novell NE2000 Ethernet MLID
  107.      NE2100.COM:         Novell NE2100 Ethernet MLID
  108.      NE3200.COM:         Novell NE3200 Ethernet MLID
  109.      NETBIOS.EXE:        Novell NetBIOS Emulation Package
  110.      NETX.EXE:           NetWare Workstation Shell
  111.      NTR2000.COM:        Novell NTR2000 Token-ring MLID
  112.      ODINSUP.COM:        ODI Support Interface for NDIS
  113.      PCN2L.COM:          IBM PC Network II and II/A MLID
  114.      ROUTE.COM:          NetWare Source Routing Driver
  115.      RPLFIX.COM:         NetWare Boot Disk Image Patch Program
  116.      RPLODI.COM:         Novell RPL ODI
  117.      TASKID.COM:         Version Task Identification Program
  118.      TBMI2.COM:          Task Switched Buffer Manager for IPX/SPX
  119.      TOKEN.COM:          IBM Token-Ring MLID
  120.      TRXNET.COM:         Novell Turbo RxNet and RxNet/2 MLID
  121.      XMSNETX.EXE:        NetWare XMS Workstation Shell
  122.  
  123.      Brief description of the document files included in the kit:
  124.  
  125.      FILE                DESCRIPTION
  126.  
  127.      BSD.TXT:            Black Screen of Death/Windows Hang suggestions. Also
  128.                          includes LSL, IPXODI and VIPX parameters and changes.
  129.      DOSODIWS.DOC:       Brief description of ODI, Token and LANSUP drivers
  130.      DOSUP8.TXT:         This file
  131.      HISTORY.DOC:        History of Shells, changes/fixes
  132.      ODIINFO.DOC:        Discussion on why Novell is promoting ODI
  133.      ODINSUP.DOC:        Information and configuration examples for ODINSUP
  134.      RPLFIX.DOC:         Information on how and when to run RPLFIX
  135.      TOKODI.DOC:         Token and LANSUP LSB mode and Bit reversal
  136.  
  137.      Installation Instructions:
  138.  
  139.      1.   Make a backup at the workstation of the associated files listed
  140.           above.
  141.  
  142.      2.   Copy the needed files to the workstation, and reboot the workstation
  143.           to have the new files take effect.
  144.  
  145.      IMPORTANT INFORMATION:
  146.  
  147.      The following drivers included in this ZIP file now default to the 802.2
  148.      frame type.  When using these drivers, it is necessary to use the 802.2
  149.      frame type on your server or change the frame type for the workstation in
  150.      your NET.CFG (or SHELL.CFG) file.
  151.  
  152.       NE1000.COM    19,807   7-30-93  9:40a   1.28
  153.      NE1500T.COM    29,258   7-30-93  9:41a   1.27
  154.          NE2.COM    20,192   7-30-93  9:36a   1.27
  155.       NE2000.COM    21,188   7-30-93  9:38a   1.53
  156.       NE2100.COM    29,256   7-30-93  9:41a   1.27
  157.       NE2_32.COM    19,903   7-30-93  9:39a   1.30
  158.       NE3200.COM    26,568   7-30-93  9:41a   1.17
  159.  
  160.      If you wish to continue to use the 802.3 frame type, place the following
  161.      two lines in the NET.CFG (or SHELL.CFG) file:
  162.  
  163.      Link Driver <drivername>
  164.              Frame Ethernet_802.3
  165.  
  166.      If you were using the NE2000.COM driver, you would replace <drivername>
  167.      with NE2000.  Be sure to indent the second line and place a carriage
  168.      return after the second line.
  169.  
  170.      PBURST.NLM
  171.  
  172.      PBURST.NLM has been removed from this version of the client update kit.
  173.  
  174.      Note:  PBURST.NLM is also used with the BNETX.EXE shell; however,
  175.      BNETX.EXE has been deleted from the client update due to a rare problem
  176.      that can result in data corruption.
  177.  
  178.      For Packet Burst support at the client, the workstation will need to be
  179.      upgraded to the VLM DOS requester technology.
  180.  
  181.      TBMI2.COM  -  This file is for use with DOS 5.0 Task Swapper, Windows 3.0
  182.      or Windows 3.1 (running in standard or real mode).
  183.  
  184.      For Windows 3.0, use TBMI2.COM and TASKID.COM. In the workstation NET.CFG
  185.      add the following parameter:
  186.  
  187.           USING WINDOWS 3.0=ON
  188.  
  189.      TBMI2 is intended for those users running programs which use the IPX or
  190.      SPX communications protocols from the DOS prompt in Windows (standard or
  191.      real mode).  TSRs running under DOS prompts in Windows Enhanced mode do
  192.      not need TBMI2, since VIPX.386 will track IPX and SPX functions. If no
  193.      DOS applications are being run which require IPX or SPX support, then
  194.      neither of these programs should be run.  To determine whether your
  195.      application requires TBMI2, follow these steps:
  196.  
  197.      1.   Load TBMI2.COM.
  198.      2.   Start Windows.
  199.      3.   Open a MS-DOS prompt.
  200.           (for Windows 3.0, load TASKID.COM.)
  201.      4.   Start the DOS application in question.
  202.      5.   Run the application and then exit.
  203.      6.   Display diagnostic information by typing the following:
  204.                TBMI2 /D
  205.      7.   If the value in the field named Far Calls Processed is not 0, you
  206.           need to run TBMI2.COM.
  207.  
  208.      To get help with TBMI2.COM, type the following: tbmi2 /?
  209.  
  210.      The default configuration for TBMI2.COM is correct for most applications.
  211.      For use with the MS-DOS 5.0 task swapper, this file is documented in the
  212.      MS-DOS 5.0 README.TXT.
  213.  
  214.      DOSNP.EXE
  215.  
  216.      This is the Named Pipes Extender for DOS.  It allows you to run Named
  217.      Pipes applications under DOS.
  218.  
  219.           Novell Named Pipe Route Enhancements
  220.  
  221.      DOS Clients
  222.  
  223.      The default has been changed to not maintain a local Named Pipe server
  224.      router table.  When a request for a DosOpen, DosWaitNmPipe, or
  225.      DosCallNmPipe is received the protocol will query the network for the
  226.      whereabouts of the Named Pipe server specified.  This means NCP services
  227.      must be available, for example, NETX.EXE or VLMs must be loaded before
  228.      DOSNP.EXE
  229.  
  230.      The following parameters can be used in the NET.CFG to configure
  231.      DOSNP.EXE.
  232.  
  233.      NP Max Machine Names = n  where n is a number between 4 and 50.  Replace
  234.      n with how many named pipe servers you want in the table. (This statement
  235.      in the NET.CFG will make the client maintain a local Named Pipe server
  236.      router table.)  (This parameter should not to be used with NP Max
  237.      Sessions) The default is 10.
  238.  
  239.      NP Max Sessions = n  where n is a number between 4 and 50.  Replace n
  240.      with the number of Named Pipe servers you want to communicate with at
  241.      once from the remote router. (This parameter should not to be used with
  242.      NP Max Machine Names) The default is 10.
  243.  
  244.      NP Max Open Named Pipes = n  where n is a number between 4 and 128. 
  245.      Replace n with the maximum number of named pipes that can be opened at
  246.      once.  The default is 4.
  247.  
  248.      RPLFIX.COM
  249.  
  250.      RPLFIX is used to allow workstations to remote program load (RPL)
  251.      properly with MS-DOS 5.x and above.  This utility must be run after the
  252.      boot image file (usually NET$DOS.SYS) has been created using the DOSGEN
  253.      utility.  RPLFIX will directly modify the boot image file; the boot image
  254.      file's size and last modified date will be different after RPLFIX has
  255.      been run.  RPLFIX only needs to be run against the boot image file once. 
  256.      Attempts to run RPLFIX against an already modified boot image file are
  257.      detected by the utility, and no further modifications will be made to the
  258.      boot image file.
  259.  
  260.      Follow the instructions for DOSGEN (setting up remote reset workstations)
  261.      in the Novell reference manuals.  For NetWare 2.x, this information can
  262.      be found in Chapter 9 of the Supervisor Guide, or Chapter 2 of the Using
  263.      the Network manual.  For NetWare 3.x, this information is found in
  264.      Appendix D of the Installation manual.  After performing all steps as
  265.      outlined in the appropriate manual to create the boot image file, run
  266.      RPLFIX.COM.  The remote workstation will likely hang during the reset
  267.      process if you are resetting using DOS 5.x or above and the boot image
  268.      file has not been modified by RPLFIX.
  269.  
  270.      RPLFIX can be found on the WSGEN diskette, or in the WSGEN subdirectory
  271.      if you are installing using a network drive.  After you have located
  272.      RPLFIX.COM, map a drive to the LOGIN subdirectory on the file server you
  273.      wish to remote reset from.  The DOSGEN procedure instructed you to create
  274.      a boot image file in that subdirectory (usually named NET$DOS.SYS).  If
  275.      the drive you mapped to SYS:LOGIN was the F: drive, then you would enter
  276.      the following:
  277.  
  278.           RPLFIX F:NET$DOS.SYS <ENTER>
  279.  
  280.      RPLFIX only needs to be run if the version of DOS loaded on the floppy
  281.      diskette used with DOSGEN is 5.x or greater.  Earlier versions of DOS do
  282.      not require that this utility be run.
  283.  
  284.      Note:  If you renamed your boot image file, then you must use the new
  285.      filename with RPLFIX:
  286.  
  287.           RPLFIX [d:]<boot image file> <ENTER>
  288.  
  289.      where  [d:] is the drive letter where the image file is located, and
  290.      <boot image file> is the name of the file created with the DOSGEN
  291.      utility.
  292.  
  293.  