home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
High Voltage Shareware
/
high1.zip
/
high1
/
DIR10
/
ZR322WB.ZIP
/
PCB.ZYR
< prev
next >
Wrap
Text File
|
1993-06-22
|
9KB
|
281 lines
Manual to install Zyrion
in PCBoard 14.5a
SysOp: Michael Friedl
╔══╗ ╔══╗
║ ║ ║ ║
║ ╚════════╝ ║
╚══════════════╝
ZyRion<Tm> Install and Command Parameters
Released By DreamScape "Another break in the wall of Communications"
Copyright 1990,91,92 By International Communication Research Holland
ZyRion
For example :
C:\MD ZYRION
C:\CD ZYRION
C:\ZYRION> ARJ E C:\NEWFILES\ZR245L1.ARJ
Now you need to "EDIT" your "BOARD.BAT" file, and add this statement
!!!! SET ZSE=C:\ZYRION !!!!! place this Line also in your BOARD.BAT !!
!!!! SET ZRLOG=C:\PCB\PCBDSZ.LOG !!!! place this Line also in your BOARD.BAT
Also include a Path statement, IF needed.
SET PATH=C:\ZYRION
At this point you are ready to - REBOOT - so that the new Environments
are active.
SETUPn
------
Second type again :
C:\CD ZYRION
C:\ZYRION> ZYRION SETUPn "Where n=COM1 - COM8 as integer."
For Example IF you want to Setup ZyRion for COM4 type
C:\ZYRION> ZYRION SETUP4
If you have more lines, then simple Setup ZyRion for each line as above
the range is from 1 - 4 [ UNREGISTERED ], and from 1 - 8 [ REGISTERED ]!
SETUP CONFIGURATION
-------------------
Third step, now you need to tell ZyRion how your configuration need to
look like.
WALK WITH ME AND LETS SETUP ZYRION!
-----------------------------------
Here you need to Enter YOUR FULL name, Will be verified if you have
a "KEY"!
Owner Name Verification [ First and Lastname ]............>First Last
Here you can change the default Async I/O Buffer Size, by Default -
this is 4096.
Don't use to big buffers, IF you decide to change the default!
I/O Buffer Size in bytes [ Press ENTER for Default ].....>use Default!
IF you use a HIGH SPEED Modem, then you'll need to enter here the
MAX. DTE Rate in Bits Per Seconds, For Example >38400 <<-put here exactly
the Speed you have specified in PCBSETUP option "D" Modem Information
Opening Baudrate: 38400 or it doesn't work if you have a Highspeedmodem!
IF Locked the -C parameter need to be used, otherwise the -B Parameter
for this purpose more later in this documentation.
Locked Rate in Bits Per Second [ Press ENTER = NON ]......>38400 !!!!!
Enable/Disable Write Buffer, this option is Default Disabled, however
IF Enabled it CAN improve your CPS rate!
IF Enabled it will use an 32 Kbyte RAM Buffer between the I/O Matrix
System of ZyRion and your HardDisk.
Enable W_Buffer [ 32 Kb -- Default = OFF ] y/N............>N
This option will Enable a security LOG so you can see who has called
with a Valid KEY or DEMO KEY or UNREGISTERED.
By Default this option is ON, Enabled, but IF you don't need it you -
can Disable it.
Enable Security Log (Create "Secure.log") Y/n.............>Y
IF you have a 16550AFN or other 16550 type installed then you should
type Y at this point to take advange of the FiFo Buffers!
Use Fifo Buffers [ 16550A..] Only Y/N.....................>i use Y
By Default ZyRion uses Direct Screen writes, but you can Disable this
method and use BIOS instead.
Use BIOS Screen writes, y/N [ Default = No ]..............>N
ZyRion will "AUTO READ" your SNP number IF a key excist, otherwise it
will be Disabled "000000000000" means, No KEY found, UNREGISTERED!
Your Serial Number Password [ ZCR Mode ] SNP..............>000000000000
Not recommended BUT if needed you can Drop the connection after a file
Transfer. (Default=NO).
This can be used IF for that line the connection need to be terminated
after each Transfer.
Drop the connection after Transfer (DTR) y/N..............>N
How many HEADER Retry's should ZyRion do, before give up (Timeout).
Default = 12 but i recommend to use 2 that means approximate 15seconds
Header Retry Counter, Sender only [ Default = 12 ]........>2
This Optional switch looks confused, but it can be usefull.
IF you logon and you have tag some files on a BBS, then the
system will ask, Press Enter to start in some cases.
If this is the case, you can just start ZyRion, and ZyRion
will handle the "CR-LF" sequence if the start mode = ON.
Other systems like Osiris SE are waiting for an "S-CR-LF"
In this case you use "Start mode = SE", IF you don't -
like this option use "Start mode = OFF", however it can
be real usefull to use at least the "ON" Method!
Use BBS Start mode [ OFF=NOT ON=NORMAL SE=NORMAL & SE ]...>OFF
This will force the receiver to use a alternate Download Path
whatsoever, the Download path on the command line, will be -
IGNORED!
IF you want a variable Download Parameter use [ ENTER ] here!
Default Download Path, or Press [ RETURN ] for NON........>NON
Here you can define how you want the calculation, in CPS or
in BPS or in "%"-Efficiency, IF you press Return here "%" -
will be used (Default).
CPS display unit E)fficiency in % or C)ps or B)ps.........>i use C
The IRQ and Base Address can be changed, for example IF your
communication port uses another IRQ for COM4, then type Y -
You'll be asked for new IRQ and Base Address, Use this option
IF you are total sure, that it need to be changed!
Change default communication settings for COM8 y/N........>
IF Y)es you'll be asked for :
Base Address, Please enter it as an INTEGER, not as 03F8!
Base Address..............................................>
IRQ Line can be given so as it is, 3, 2, 4 , e.c
IRQ Line for this port....................................>
ZYRION DEFAULT BASE & IRQ LINES ARE
-----------------------------------
All Ports below are defined as in Chuck Forsbergs DSZ and YAM to stay -
compatible with GSZ/DSZ/YAM/ZCOMM
Base Address Irq Line COMX Portn Fossil
-------------------------------------------------------
BASE1 := 03F8 IRQ1 := 4 COM1 1 0
BASE2 := 02F8 IRQ2 := 3 COM2 2 1
BASE3 := 03E8 IRQ3 := 4 COM3 3 2
BASE4 := 02E8 IRQ4 := 3 COM4 4 3
BASE5 := 02B8 IRQ5 := 3 COM5 5 4
BASE6 := 02B8 IRQ6 := 2 COM6 6 5
BASE7 := 02F8 IRQ7 := 2 COM7 7 6
BASE8 := 0278 IRQ8 := 2 COM8 8 7
PARAMETER LIST
--------------
R <______> First parameter R = RECEIVE Lower or Uppercase "R|r"
S <______> First parameter S = SEND Lower or Uppercase "S|s"
-P <______> Second parameter [ -Pn where n = portnumber ]
-B <______> Third parameter [ -Bnnnnnn Baud rate REAL or 0 = Abarated ]
-C <______> Third parameter [ -Cnnnnnn Baud rate CONNECT from Modem ]
Use this one IF your DTE rate is constant [ LOCKED! ]
@ <______> Send files from control file @SEND.CTL <-- ASCII PLAIN FILE
. <______> In receive mode, indicate current path
Setupn <__> Setup or Re-Setup n where n is the Portnumber
This would be look like this, NOTE: locked!
ECHO OFF
CLS
ZYRION R -P%1 -C38400 %3\*.*
You'll get this : ZYRION R -P4 -C38400 C:\PCB\PRIVUPLD\
ECHO OFF
CLS
ZYRION S -P%1 -C38400 %3
You'll get this : ZYRION S -P%1 -C38400 @PCBDSZ.LST
Note: For "NOT LOCKED" you can also use -B0, this will enable the Abarate
routine, this is a short word for Auto Baud Rate, in other words ZyRion
will figur out what your UART rate is!
Final the @<control File> option, this can be usefull if you send a lot of
files, since DOS will not allow that many.
FILES
You need to set the statement FILES= at least to 20, so FILES=20!
Otherwise ZyRion will abort, because it need to open a lot of files in
some cases.
PS: if you ask why install ZYRION i tell you that i have in V32bis
Connects 1800 Cps with ZIP-filetransfer and 3800 Cps with ASCI.
in 16.800k HSTmode i have near 2100 Cps in ZIP-filetransfers.
thats why !
enjoy with ZYRION
your SysOp: Michael Friedl