home *** CD-ROM | disk | FTP | other *** search
/ High Voltage Shareware / high1.zip / high1 / DIR10 / SUPRAHLP.ZIP / AT_LIST.TXT next >
Text File  |  1993-07-20  |  45KB  |  982 lines

  1. Full AT Command Set Listing for the SupraFAXModem Series
  2.  
  3. NOTE:   This file includes commands, result codes, and display codes
  4.         NOT AVAILABLE on all models and revisions.  Some commands are new
  5.         or were omitted from Reference Manual.  NOT ALL commands are
  6.         available or functional in all modes and states.  This document
  7.         is provided for reference only and is NOT certified to be free
  8.         from errors.  This document is produced and maintained by Supra's
  9.         Technical Support Staff as a customer service.
  10.  
  11. AT_LIST.TXT   Rev 2.9  (PHM 7/20/93)  from Supra BBS (503)967-2444
  12.  
  13. The command string buffer on the SupraFAXModem is limitted to 254 charactors.
  14.  
  15. DIRECT Commands (Commands NOT preceded by other charactors)
  16.  
  17. A/      Re-execute Last Command
  18. nnn     Escape Code per setting in register S2 (Default is ANSI charactor 43,
  19.         the "+" symbol) (This command must be proceded and followed by a
  20.         minimum period of no transmission set is register S12.)
  21. <CR>    (A carriage return) - Terminate connection attempt in progress during
  22.         the dialing or protocol neg. process.
  23.  
  24. DIALING Commands (Commands that follow ATD)
  25.  
  26. -()i    These symbols and spaces are ignored (or invalid and therefore ignored)
  27.          and maybe be used in the dialing string.
  28. 0-9     DTMF code for the given number
  29. A-D     DTMF code for the given letter
  30. J       Do MNP 10 link negotiation at highest rate (this call only, see *H)
  31. K       Enable power level adj. during MNP 10 link neg. (this call only, see Mn)
  32. L       Dial the last dialing string (limitted to the first 40 charactors).
  33. P       Pulse dial the following digits
  34. R       Reverse Carrier Mode (Dial with ANSWER rather than ORIGINATE carrier.)
  35.          (Some models accept, but do not support, this command.)
  36.          Normal Mode:   Calling Side: ATDTn     Answering Side: ATA
  37.          Reverse Mode:  Calling Side: ATDTnR    Answering Side: ATXD
  38. Sn      Use dialing string stored in register n (0 to 3)
  39. T       Tone dial the following digits
  40. W       Wait for dialtone
  41. *       DTMF code for "star"
  42. #       DTMF code for "gate"
  43. @       Wait for "quiet answer" (A 5 second silence.)
  44. ,       Pause (time set in S8) before finishing dialing string
  45. !       Hook flash (go on-hook for 700ms)
  46. ^       Turn on 1300Hz call originating pulse
  47. ;       Return to command state after dialing (last command processed in string)
  48. >       Generate a grounding pulse on the EARTH relay output
  49.          (If country code setting supports it)
  50.  
  51. AT Commands (Commands that follow AT)
  52.  
  53. =x      Write value x to the last S register viewed.
  54. ?       Displays current setting for the last S register accessed.
  55. A       Answer Phone Line
  56. Bn      BELL/CCITT mode switch at 300 & 1200 bps
  57.          B0=CCITT
  58.          B1=BELL (default in North America)
  59. C1      Carrier Control Selection
  60.          Provided for backward compatibility only. Does nothing but return "OK"
  61. D       Dial Command
  62.          Dials any mixed string of dialing commands. (See Dialing Commands)
  63. En      Command Echo
  64.          E0=not echo
  65.          E1=do echo (default)
  66. Fn      {Function varies by model}
  67.         On-line State Character Echo Selection
  68.          F0 Not Supported (Returns "ERROR")
  69.          F1 Provided for backward compatibility only. (Returns "OK")
  70.  
  71.         Line Select Modulation (Use either ATFn or a combination of ATS37=n
  72.                 and ATN0, but DO NOT try to USE BOTH at the same time.)
  73.          F0     AutoMode Selection (try rates in order from fast to slow).
  74.          F1     300 bps only (protocol according to Bn setting)
  75.          F2     Not Used (return "OK")
  76.          F3     v.23 only 75TX/1200RX (originate) or 1200TX/75RX (answer)
  77.          F4     1200 bps only (protocol according to Bn setting)
  78.          F5     2400 bps only (v.22bis)
  79.          F6     4800 bps only (v.32/v.32bis)
  80.          F7     7200 bps only (v.32bis)
  81.          F8     9600 bps only (v.32/v.32bis)
  82.          F9     12000 bps only (v.32bis)
  83.          F10    14400 bps only (v.32bis)
  84.  
  85. Hn      Hook Control
  86.          H0=On-Hook (Hang Up)
  87.          H1=Off-Hook (pick up phone line)
  88. In      Identification Codes
  89.          I0=SupraFAXModem product ID code
  90.          I1=ROM checksum
  91.          I2=Test Checksum (OK if correct, ERROR if not)
  92.          I3=ROM revision code
  93.          I4=Encrypted report of supported protocols
  94.          I5=Supra Copyright info.
  95.          I6=Country Code for country PSTN Signals are Configured for.
  96.          I10=Supported Features (encoded - see end of text for listing)
  97. Ln      Speaker Volume
  98.          L0,L1   Low
  99.          L2      Medium (default)
  100.          L3      High
  101. L+n     Increase Total Volume Gain n units (1-32) (Not the same as Ln)
  102. L-n     Decrease Total Volume Gain n units (1-32) (Not the same as Ln)
  103. Mn      Speaker Control
  104.          M0      OFF
  105.          M1      On until carrier is received (default)
  106.          M2      Always On
  107.          M3      On when answering/On only after dialing & until carrier detect
  108. Nn      AutoMode Connection (Carrier Rate when Originating Call)
  109.          N0=Connect ONLY at rate set in S37 register
  110.             (N0S37=0 forces the modem to dial at the current serial port rate.)
  111.          N1=Connect Normally (default)
  112. On      Return from COMMAND MODE to ONLINE state
  113.          O0=Return to ONLINE state
  114.          O1=Request a retrain & Return to ONLINE state
  115. P       Set dialing mode to PULSE
  116. Qn      Result Code Mode
  117.          Q0=Enabled (Default)
  118.          Q1=Disabled
  119.          Q2=Enabled when Originating, Disabled when answering
  120. Sr?     Reports value in S register r
  121. SCr?    Reports value is SC register r
  122. Sr=n    Write value n into S register r
  123. SCr=n   Write value n into SC register r
  124. T       Set dialing mode to TONE
  125. Vn      Result Code mode select
  126.          V0=Numeric
  127.          V1=Verbose (default)
  128. Wn      Error Correction Result Code Selection
  129.          W0=CONNECT XXXX (DTE rate) (default)
  130.          W1=Report Error Correction Mode
  131.          W2=CONNECT XXXX (DCE rate)
  132. Xn      Dialing mode/CONNECT result codes
  133.          X0=Blind Dial (ignore Dialtone & Busy), send CONNECT
  134.          X1=Blind Dial, send CONNECT XXXX
  135.          X2=follow Dialtone, but ignore Busy, send CONNECT XXXX
  136.          X3=follow Busy, but ignore Dialtone, send CONNECT XXXX or BUSY
  137.          X4=send CONNECT XXXX, BUSY, or NO DIALTONE (default)
  138. Yn      Long Space Disconnect
  139.          Y0=Not active (default)
  140.          Y1=Active (see manual)
  141. Zn      Soft reset and Load Stored profile n (last functional command on line)
  142.          Z0=resets modem & loads stored profile 0
  143.          Z1=resets modem & loads stored profile 1
  144.  
  145. -Kn     MNP Extended Services (MNP 10)
  146.          -K0    Disable v.42 LAPM to MNP 10 connection
  147.          -K1    Enable v.42 LAPM to MNP 10 connection
  148. -Qn     Fallback to v.22bis/v.22 in MNP10 mode
  149.          -Q0    Disabled (Fallback only allowed to 4800 bps)
  150.          -Q1    Enabled (Fallback allowed to v.22bis/v.22) (Default)
  151.  
  152. &Cn     DCD (RLSD) signal control
  153.          &C0=DCD always on
  154.          &C1=DCD follows carrier state (ON when carrier present)
  155. &Dn     Modem reaction to DTR on to off transition greater than S25 setting
  156.               a  b  c  d  e  (Settings of &Qn)
  157.          &D0= N  1  3  3  1
  158.          &D1= 2  2  3  3  2
  159.          &D2= 3  3  3  3  3
  160.          &D3= 4  4  3  3  4
  161.  
  162.          List of modem reactions:
  163.  
  164.          N=No Action
  165.          1=Disconnect & send OK result code
  166.          2=Swith to asynchronous command state
  167.          3=Disconnect return to command state (Answer disabled while DTR is off)
  168.          4=Perform soft reset (like ATZ0)
  169.  
  170.          List of &Q states:
  171.          a. &Q0, &Q5, &Q8, or &Q9
  172.          b. &Q1
  173.          c. &Q2
  174.          d. &Q3
  175.          e. &Q4
  176.  
  177. &Fn     Load Factory Default Configuration
  178.          &F0     No flow control, No error correction, No data compression
  179.          &F1     MAC hardware flow control, correction & compression active
  180.          &F2     Hardware flow control, correction & compression active
  181.                  (&F2 is default for DOS, WINDOWS, AMIGA, & STAND ALONE units.)
  182. &Gn     Guard Tone Selection
  183.          &G0     Do Not generate guard tones   (US Default)
  184.          &G1     Generate 550Hz guard tone     (not supported)
  185.          &G2     Generate 1800Hz quard tone    (World Wide support models only)
  186. &Jn     Phone Jack Selection
  187.          &J0     Select RJ-11, RJ-41, & RJ-45S (Default)
  188.          &J1     Select RJ-12 & RJ-13          (not supported)
  189. &Kn     Serial Port Flow Control
  190.          &K0=None
  191.          &K3=Bidirectional Hardware (RTS/CTS)
  192.          &K4=Software (XON/XOFF)
  193.          &K5=Transparent Software flow control
  194.          &K6=Software (XON/XOFF) & Hardware (RTS/CTS) flow control
  195. &Ln     Line Type Selection
  196.          &L0    Dial-up line (Default)
  197.          &L1    Leased Line  (not supported)
  198. &Mn     Same function as &Q(0-3) settings.
  199. &Pn     Pulse dialing MAKE/BREAK ratio {varies by model}
  200.  
  201.          &P0 39%/61% make/break ratio at 10PPS {US/CANADA}  (Default)
  202.          &P1 33%/67% make/break ratio at 10PPS {UK/Hong Kong}
  203.          &P2 33%/67% make/break ratio at 20PPS {Japan}
  204.    
  205.          &P0 39%/61% make/break ratio at 10PPS {US/CANADA}  (Default)
  206.          &P1 33%/67% make/break ratio at 10PPS {UK/Hong Kong}
  207.          &P2 39%/61% make/break ratio at 20PPS
  208.          &P3 33%/67% make/break ratio at 20PPS {Japan}
  209.  
  210. &Qn     Asynchronous/Synchronous Mode Selection
  211.          &Q0     Asynchronous Direct mode
  212.          &Q1 *   Synchronous Mode 1 (Terminal must support both modes.)
  213.                   Call placed Async, modem switches to Sync. When DTR is dropped
  214.                  modem returns to Async.
  215.          &Q2 *   Synchronous Mode 2 Modem dials number in stored location 0
  216.                   when DTR goes from LOW to HIGH.
  217.          &Q3 *   Synchronous Mode 3 Dial number manually on a telephone, and
  218.                   then bring DTR high to let the modems connect.
  219.      * CAUTION!  Be VERY careful when issuing these commands!  Once you enter
  220.                   &Q(1-3) and save it to memory, there are only three known
  221.                   ways to return to Asynchronous Mode:
  222.                  1. Issue AT &Q(0,5-9) &W from a Synhronous Terminal to restore
  223.                     the modem to Asynchronous Mode.
  224.                  2. Connect modem to an Asynchronous Terminal with the DTR
  225.                     signal (line 20) disabled (a "break-out" box works very
  226.                     nicely for this) and issue the configuration you want or
  227.                     AT &Q(0,5-9) &W to return the modem to Asynchronous Mode.
  228.                  3. Send the modem in to our repair department.
  229.          &Q4     Not Used
  230.          &Q5     Asynchronous Reliable Mode (most common default)
  231.          &Q6     Asynchronous Normal Mode
  232.          &Q7     Not used
  233.          &Q8     Asynchronous Reliable Mode w/o v.42/v.42bis
  234.          &Q9     Asynchronous Reliable Mode w/o MNP 2-5
  235. &Rn     RTS Synchronous Mode
  236.          (In Asynchronous mode CTS is always ON unless &K3 is set.)
  237.          &R0     CTS responds to RTS (default)
  238.          &R1     CTS always on unless &K3 is set
  239. &Sn     DSR Action Select
  240.          &S0 Always on (default)
  241.          &S1 Follows EIA specification (Active following carrier tone, and
  242.           until carrier is lost.)
  243. &Tn     Modem test modes for trained technicians (you must set the serial port
  244.           at 2400 or 9600, set the modem with AT&F0, and set S18 between 1 and
  245.           255if you wish the tests to stop on their own.)
  246.          AT&T0   Terminate test in progress
  247.          AT&T1   Local Analog Loopback (+++ then &T0 to stop)
  248.          AT&T2   Returns ERROR
  249.          AT&T3   Local Digital Loopback for remote modem
  250.          AT&T4   Grant request for Remote Digital Loopback (default)
  251.          AT&T5   Prohibit request for Remote Digital Loopback
  252.          AT&T6   Remote Digital Loopback
  253.          AT&T7   Remote Digital Loopback with self-test
  254.          AT&T8   Local Analog Loopback with self-test (+++ then &T0 to stop)
  255. &V      Display Configuration Profiles
  256. &Wn     Write ACTIVE Profile to Stored Profile n
  257.          &W0     Writes to profile 0
  258.          &W1     Writes to profile 1
  259. &Xn     Synchronous Transmit Clock Source
  260.          &X0=Modem generated (default)
  261.          &X1=DTE supplied
  262.          &X2=Derived from the data carrier received from the remote modem.
  263. &Yn     Select Configuration Loaded at power-up
  264.          &Y0=Load profile 0 (default)
  265.          &Y1=Load profile 1
  266. &Zx=n   Write stored telephone number x (0 to 3) the number n.
  267.  
  268. \An     Maximum MNP Block Size for Stream Links
  269.          \A0     64 characters
  270.          \A1     128 characters
  271.          \A2     192 characters (default - although may vary by model)
  272.          \A3     256 characters
  273. \Bn     Transmit Break of length n x 100ms where n is 1 to 9 in non-error
  274.          correction state.  (Sends Link Attention in MNP mode)
  275. \En     Optimize Echo Cancellation {accepted, but not functional on some models}
  276.          \E1 One shot that minimizes local echo to try to match local network
  277. \F      Display Telephone Directory (As stored via AT&Zn)
  278. \Gn     Modem-to-Modem XON/XOFF flow control (Normal and Direct Mode Only)
  279.          \G0=Disabled (default)
  280.          \G1=Enabled
  281. \Jn     Enable DTE Auto Rate Adjustment
  282.          \J0    Disabled
  283.          \J1    DTE rate is adjusted to match carrier rate.
  284. \Kn     Break Processing Control (controls remote modem during MNP mode)
  285.          When received from local DTE & Modem is in Data Transfer Mode:
  286.           \K0,\K2,\K4   Enter command state without sending BREAK to remote
  287.           \K1           Clear Modem & Terminal Buffers & send BREAK to remote
  288.           \K3           Don't clear Buffers, but send BREAK to remote
  289.           \K5(default)  Send BREAK to remote in sequence with any transmitted
  290.                          data (default)
  291.          In Escape (Online Command) mode:
  292.           \K0,\K1           Clear data buffers and sends break to remote modem.
  293.           \K2,\K3           Send break to remote modem immediately.
  294.           \K4,\K5(default)  Send break to remote modem in sequence with data.
  295.          When received from remote modem in non-error correction mode:
  296.           \K0,\K1           Clear data buffers and sends break to DTE
  297.           \K2,\K3           Send break to DTE immediately.
  298.           \K4,\K5(default)  Send break in sequence with received data to DTE.
  299. \Ln     MNP Block Transfer Control
  300.          \L0     Use Stream Mode for MNP Links (default)
  301.          \L1     Use Block Mode for MNP Links
  302. \N      Operating Mode
  303.          \N0     Normal Mode
  304.          \N1     Direct Mode
  305.          \N2     MNP Reliable Mode
  306.          \N3     AutoReliable Mode
  307. \O      Originate MNP Reliable Mode Request
  308. \S      Report Active Configuration
  309. \Tn     Set Inactivity Timer (Modem disconnects if no activity in time n.)
  310.          \Tn=0            Timer disabled (default)
  311.          \Tn=1 to 42      Modem disconnects after n minutes without activity
  312. \U      Accept MNP Reliable Request (request must occur within 12 seconds)
  313. \W      Split-Speed Operation (v.23)
  314.          \W0    Disable split-speed mode (default)
  315.          \W1    Enable split-speed mode v.23 (forces F3)
  316. \Y      Switch to MNP Reliable Mode
  317. \Z      Switch from MNP to Normal Mode
  318.  
  319. %Cn     Data Compression Enable/Disable
  320.          %C0     Disabled
  321.          %C1     MNP5 Enabled
  322.          %C2     V.42bis (BTLZ) Enabled
  323.          %C3     MNP5 & V.42bis (BTLZ) Enabled
  324. %Dn     BTLZ Dictionary Size
  325.          %D0=512
  326.          %D1=1024
  327.          %D2=2048 (default)
  328.          %D3=4096 (if one-way compression %M1 or %M2 is enabled)
  329.              2048 (if two-way compression %M3)
  330. %En     Auto Retrain & Fallback/Fall Forword based on line quality monitoring
  331.          %E0=Disabled (Default)
  332.          %E1=Enable Auto Retrain based on line quality
  333.          %E2=Enable Fallback/Fall Forward baed on line quality
  334. %Fn     Split-Speed Direction Select
  335.          %F1    75TX/1200RX
  336.          %F2    1200TX/75RX
  337.          %F3    v.23 Half-Duplex (independant of \W)
  338. %Gn     Rate Renegotiation based on line monitor readings
  339.          %G0=Disabled
  340.          %G1=Enabled (Default)
  341. %L      Reports Received Signal Level (at connection to DSP) nnn in -dBm.
  342.          nnn=9 or stronger       reports as 9
  343.          nnn=10 to 42            reports as value directly
  344.          nnn=43 or weaker        reports as 43
  345. %Mn     {Function varies by model}
  346.         AUXCTL Output Line Control
  347.          %M0    Line high only while modem in synchronous data mode (default)
  348.          %M1    Line low only while modem in synchronous data mode
  349.         BTLZ Compression Mode
  350.          %M0     Disabled
  351.          %M1     Transmit compression only
  352.          %M2     Receive compression only
  353.          %M3     Two-way compresion (default)
  354. %P      Clear Local & Remote Modems' BTLZ Dictionaries
  355. %Q      Report Received signal Quality (nnn range 0 to 127)
  356.          nnn=1 to 8 current signal quality excellent (higher rate may be used)
  357.          nnn=9 to 20 current signal good (best carrier rate for line condition)
  358.          nnn=20 to 30 current signal poor (lower carrier rate should be used)
  359.          nnn=31 to 127 signal very bad (or gone), try forcing a lower rate
  360.          NOTE: Modem uses 8 and 20 as rate renegotiation watermarks.
  361. %Sn     Set Maximum BTLZ string length n (6 to 250)   (default is 32)
  362. %TTnn   PTT Testing Utilities
  363.         (Set S10=255 to transmit data in the absence of a received signal)
  364.         00-09   DTMF tone dial digits 0 to 9
  365.         0A      DTMF digit *
  366.         0B      DTMF digit A
  367.         0C      DTMF digit B
  368.         0D      DTMF digit C
  369.         0E      DTMF digit #
  370.         0F      DTMF digit D
  371.         10      v.21 channel #1 mark (originate) symbol
  372.         11      v.21 channel #2 mark symbol
  373.         12      v.23 backward channel mark symbol
  374.         13      v.23 forward channel mark symbol
  375.         14      v.22 originate signalling at 600 bps
  376.         15      v.22 originate signalling at 1200 bps
  377.         16      v.22bis originate signalling at 2400 bps
  378.         17      v.22 answer signalling (guard tone if PTT required)
  379.         18      v.22bis answer signalling (quard tone if required)
  380.         19      v.21 channel #1 space symbol
  381.         1A      v.21 channel #2 space symbol
  382.         1B      v.23 backward channel space symbol
  383.         1C      v.23 forward channel space symbol
  384.         1D      v.27ter carrier
  385.         1E      v.29 carrier
  386.         20      v.32 @9600 bps
  387.         21      v.32bis @14400 bps
  388.         22      v.17 @14400 bps
  389.         30      Silence (on-line) - i.e. go off-hook
  390.         31      v.25 answer tone
  391.         32      1800 Hz guard tone
  392.         33      v.25 calling tone (1300Hz)
  393.         34      Fax calling tone (1100Hz)
  394.                                          
  395. *B      Return Blacklisted Numbers
  396.          Displays a numbered chart of currently BLACKLISTED numbers {Except
  397.          permanently forbidden numbers based on country setting}  "OK" is
  398.          returned if no temporary numbers are BLACKLISTED.
  399. *C      Remote Password Configuration (for MNP connections ONLY)
  400.          Gives ENTER PASSWORD prompt and accepts a 6 to 12 charactor
  401.          alphanumeric string.  (Default is QWERTY)
  402. *D      Return Delayed Numbers
  403.          Displays a numbered chart of DELAYED numbers and the length of delay
  404.          in the format HH:MM:SS  "OK" is returned if no numbers are delayed.
  405. *E      Exit Remote Configuration Mode
  406. *Hn     Link Negotiation Speed (MNP 10)
  407.          *H0    Link negotiation occurs at highest supported rate (Default)
  408.          *H1    Link negotiation occurs at 1200 bps.
  409.          *H2    Link negotiation occurs at 4800 bps.
  410. *L      Display Secure Access Directory
  411.          Displays a numbered chart (0-19) of all secure access (callback)
  412.          directory entries in the following format: #-Password:Callback_Number
  413.          If no callback number is set then the colon is omitted.
  414. *NCnn   Country Select
  415.          Sets country PSTN parameters to the code number specified.
  416.          ERROR is returned if the country selected is not currently supported.
  417. *Px:p:n Store/Delete a Password/Phone Number Pair
  418.         *Px(0-19):p(password of 6 to 12 charactors):n(0 to 40 dialing codes)
  419.          If the last colon and dialing codes are omitted then password check
  420.          occurs, but no call-back occurs.
  421. *R      Request Remote Configuration Mode (during MNP mode connection ONLY)
  422.          If successful, a REMOTE PASSWORD prompt is display, and you should
  423.          issue the 6 to 12 charactor password currently set.  If the password
  424.          is accepted, a !AT prompt will be displayed and a limitted set of
  425.          commands can then be issued with the "AT" header omitted.  Exit this
  426.          mode with the *E command.
  427. *Zn     Change Dialing Codes (Used in countries like NORWAY that support two
  428.                 methods of pulse dialing.)
  429.          *Z0    Use dial code 0 (default)
  430.          *Z1    Use dial code 1
  431.  
  432. #CID?   Displays current CallerID mode (0-2)
  433. #CID=n  Caller ID Mode
  434.          #CID=0 Disable Caller ID (Default)
  435.          #CID=1 Enable Formatted Caller ID Mode
  436.           Result code syntax is as follows:
  437.            DATE=MMDD (where MM is month number 01-12 & DD is day 01-31)
  438.            TIME=HHMM (where HH is hour 00-23 & MM is minute 00-59)
  439.            NMBR= number code or statement
  440.             Statements are used for calls from non-CallerID Areas and
  441.             subscribers requesting not to be displayed.  The NMBR code format
  442.             is controlled by the phone service provider, but seems to follow
  443.             one of two patterns:
  444.  
  445.             5039672400 (area_code, local_exchange, subscriber_number)
  446.  
  447.             037035303339363732343030
  448.             CCCC^N^N^N^N^N^N^N^N^N^N C is Code, ^ is spacer symbol, N is number
  449.                  5 0 3 9 6 7 2 4 0 0 (notice the number is still included)
  450.             
  451.            NAME= listed subscriber name <this is an option not always supported>
  452.          #CID=2 Enable Raw (ASCII printable HEX number) Mode
  453.          #CID=? Returns Caller ID Modes supported.
  454. )M      Cellular Power Level Adjustments (MNP 10)
  455.          )M0    Power not adjusted during MNP 10 link negotiation (Default)
  456.          )M1    Power level adjusted during MNP 10 link negotiation.
  457.  
  458. V.25 BIS Command Set
  459.  
  460.         **** Coming soon! ****
  461.  
  462. S Registers
  463.  
  464. S0      Number of Rings to Auto Answer (0 to 255) (0 is disable & default)
  465. S1      Number of Rings before last answer.
  466. S2      Escape Code character (0 to 255) (default is 43 "+")
  467. S3      Carriage Return character (0-127) (default is 13)
  468. S4      Line Feed character (0-127) (default is 10)
  469. S5      Backspace character (0-32) (default is 8)
  470. S6      Time to Wait before Blind Dial (2-255 seconds)  (default is 2)
  471.          (Applies only in X,X1, or X3 dialing mode)
  472. S7      Time to Wait for Carrier (1-255 seconds) (default is 50)
  473. S8      Pause Time for Comma Dial Command (0-255 seconds) (default is 2)
  474. S9      Time to Wait Before Recognizing Carrier (1-255 1/10 seconds)
  475.          (Default is 6)
  476. S10     Delay from Lost Carrier to Hang Up (1-255 1/10 seconds) (Default is 14)
  477. S11     DTMF Tone Duration/Spacing (35 to 102 1/100 seconds) (Default is 95)
  478. S12     Escape Code Guard Time (0 to 255 1/50 seconds) (0 to disable, the
  479.          default is 50)
  480. S13     Reserved
  481. S14     Bit Mapped Option Status Codes
  482.         Bit(Dec)
  483.          0 (1)   Reserved
  484.          1 (2)   Command echo (En)
  485.                   0 Disabled (E0)
  486.                   1 Enabled  (E1 default)
  487.          2 (4)   Quiet Mode (Qn)
  488.                   0 Send result codes (Q0 default)
  489.                   1 No result codes   (Q1)
  490.          3 (8)   Result codes (Vn)
  491.                   0 Numeric (V0)
  492.                   1 Verbose (V1 default)
  493.          4 (16)  Reserved
  494.          5 (32)  Dial Mode
  495.                   0 Tone  (T default)
  496.                   1 Pulse (P)
  497.          6 (64)  Reserved
  498.          7 (128) Carrier Mode
  499.                   0 Answer
  500.                   1 Originate
  501. S15     Reserved
  502. S16     Diagnostic Test Mode setting -Bit Mapped (default 0)
  503.          0       &T1     0 Disable       1 Enable
  504.          1       Not Used
  505.          2       &T3     0 Disable       1 Enable
  506.          3       &T4/&T5 0 Off           1 In progress
  507.          4       &T6     0 Disable       1 Enable
  508.          5       &T7     0 Disable       1 Enable
  509.          6       &T8     0 Disable       1 Enable
  510.          7       Not Used
  511. S17     Reserved
  512. S18     Test Mode Timer (0-255 seconds, 0=Runs endlessly)
  513. S19     Reserved
  514. S20     Reserved
  515. S21     Bit Mapped Option Status Codes
  516.         Bit(Dec)
  517.          0 (1)   Set by &Jn command but ignored otherwise
  518.                   0 &J0 (default)
  519.                   1 &J1
  520.          1 (2)   Reserved
  521.          2 (4)   CTS Mode (&Rn)
  522.                   0 CTS always on   (&R0)
  523.                   1 CTS follows RTS (&R1 default)
  524.          3 (8) & 4 (16) DTR behavior (&Dn)
  525.                   0,0 &D0 (default)
  526.                   1,0 &D1
  527.                   0,1 &D2
  528.                   1,1 &D3
  529.          5 (32)  DCD (RLSD) behavior (&Cn)
  530.                   0 &C0 (Default)
  531.                   1 &C1
  532.          6 (64)  DSR behavior (&Sn)
  533.                   0 &S0 (Default)
  534.                   1 &S1
  535.          7 (128) Long space diconnect (Yn)
  536.                   0 Y0  (Default)
  537.                   1 Y1
  538. S22     Bit Mapped Option Status Codes
  539.         Bit(Dec)
  540.          0 (1) & 1 (2)  Speaker volume (Ln)
  541.                   0,0 Low    (L0)
  542.                   1,0 Low    (L1)
  543.                   0,1 Medium (L2 default)
  544.                   1,1 High   (L3)
  545.          2 (4) & 3 (8)  Speaker control (Mn)
  546.                   0,0 Disabled            (M0)
  547.                   1,0 On until carrier    (M1 default)
  548.                   0,1 ON Always           (M2)
  549.                   1,1 On during handshake (M3)
  550.          4 (16), 5 (32), & 6 (64) Dialing Mode / Result Codes (Xn)
  551.                 0,0,0 X0
  552.                 1,0,0 Reserved
  553.                 0,1,0 Reserved
  554.                 1,1,0 Reserved
  555.                 0,0,1 X1
  556.                 1,0,1 X2
  557.                 0,1,1 X3
  558.                 1,1,1 X4 (Default)
  559.          7 (128) Reserved
  560. S23     Bit Mapped Option Status Codes
  561.         Bit(Dec)
  562.          0 (1)   Grant RDL
  563.                   0 RDL not allowed (&T5)
  564.                   1 RDL allowed     (&T4 default)
  565.          1 (2), 2 (4), & 3 (8) Assumed DTE Rate
  566.                 0,0,0 0-300 bps
  567.                 1,0,0 600 bps
  568.                 0,1,0 1200 bps
  569.                 1,1,0 2400 bps (Default)
  570.                 0,0,1 4800 bps
  571.                 1,0,1 9600 bps
  572.                 0,1,1 19200 bps
  573.                 1,1,1 Reserved
  574.          4 (16) & 5 (32) Assumed DTE parity
  575.                   0,0 Even
  576.                   1,0 Reserved
  577.                   0,1 Odd
  578.                   1,1 None (default)
  579.          6 (64) & 7 (128) Guard tone (&Gn)
  580.                   0,0 None    (&G0 Default)
  581.                   1,0 550 Hz  (&G1)
  582.                   0,1 1800 Hz (&G2)
  583.                   1,1 Reserved
  584. S24     Sleep Inactivity Timer (0-255 seconds 0 default/disable)
  585.          Number of seconds before modem enters sleep mode without either DTE or
  586.          phone line activity.
  587. S25     Delay to DTR (0-255 1/100 seconds, 5 default)
  588. S26     RTS/CTS Delay (0-255 1/100 seconds, 1 default) (Sync mode only)
  589. S27     Bit Mapped Option Status
  590.         Bit(Dec)
  591.          0 (1), 1 (2), 3 (8) Sync/Async Mode Selection (&Mn/&Qn)
  592.                 0,0,0 &M0/&Q0
  593.                 1,0,0 &M1/&Q1
  594.                 0,1,0 &M2/&Q2
  595.                 1,1,0 &M3/&Q3
  596.                 0,0,1 &Q4
  597.                 1,0,1 &Q5 (Default)
  598.                 0,1,1 &Q6
  599.          2 (4)   Leased line control (&Ln)
  600.                   0 Dial-up line (&L0 default)
  601.                   1 Leased line  (&L1)
  602.          4 (16) & 5 (32) Internal Sync clock select (&Xn)
  603.                   0,0 Internal (&X0 default)
  604.                   1,0 External (&X1)
  605.                   0,1 Slave    (&X2)
  606.          6 (64)  CCITT/Bell Mode (Bn)
  607.                   0 CCITT (B0)
  608.                   1 Bell  (B1 US default)
  609.          7 (128) Reserved
  610. S28     Bit Mapped Options
  611.         Bit(Dec)
  612.          0 (1)   V.23 split screen (\Wn)
  613.                   0 Disabled (\W0 default)
  614.                   1 Enabled  (\W1)
  615.          1 (2)   V.23 split screen direction
  616.                   0 75Tx   (%F0 default)
  617.                   1 1200Tx (%F1 default)
  618.          2 (4)   V.23 half-duplex
  619.                   0 Disabled
  620.                   1 Enabled (%F3)
  621.          3 (8) & 4 (16)
  622.                  Pulse dialing mode (&Pn)
  623.                   0,0 &P0 (Default)
  624.                   1,0 &P1
  625.                   0,1 &P2
  626.                   1,1 &P3
  627.          5 (32)  Reserved
  628.          6 (64)  Reserved
  629.          7 (128) Reserved
  630. S29     Flash Dial Modifier Time
  631. S30     Inactivity Timer (0-255 Unit 10 seconds, 0=disable {default})
  632.          In Reliable mode any data transfer resets timer.
  633.          In Normal mode only sent data resets timer.
  634. S31     Bit Mapped Options
  635.         Bit(Dec)
  636.          0 (1)   Reserved
  637.          1 (2)   Auto Mode Selection
  638.                   0 Disabled (N0)
  639.                   1 Enabled  (N1 default)
  640.          2 (4), 3 (8) Error Correction Result Code (Wn)
  641.                   0,0 DTE Speed only (W0 default)
  642.                   1,0 Full Reporting (W1)
  643.                   0,1 DCE Speed only (W2)
  644.          4 (16)  Reserved
  645.          5 (32)  Reserved
  646.          6 (64)  Reserved
  647.          7 (128) Reserved
  648. S32     XON Charactor (0-255, Default 17)
  649. S33     XOFF Charactor (0-255, Default 19)
  650. S36     Negotiation Failure Treatment (0-7  7 is default)
  651.          Fallback options when S48=128 or error correction link fails:
  652.          0       Disconnect
  653.          1       Establish Direct connection
  654.          2       Undefined
  655.          3       Establish Normal connection
  656.          4       Establish a MNP connection if possible, else Disconnect
  657.          5       Establish a MNP connection if possible, else Direct connection
  658.          6       Undefined
  659.          7       Establish a MNP connection if possible, else Normal connection
  660. S37     Forced Single Carrier Rate (0-1,5-12  0 is default)
  661.          0       Carrier Rate at the rate the last AT command was issued.
  662.                  (If rate is above highest carrier rate, then the highest
  663.                  carrier rate the modem supports is used.)
  664.          1       300 bps
  665.          2-4     Undefined
  666.          5       1200 bps
  667.          6       2400 bps
  668.          7       1200/75 bps    (v.23 mode)
  669.          8       4800 bps
  670.          9       9600 bps
  671.          10      12000 bps
  672.          11      14400 bps
  673.          12      7200 bps
  674. S38     Delay Before Forced Disconnect (0-255 seconds, default 20)
  675.          0-254   Delay in seconds from H command, or DTR toggle ON or OFF (if
  676.                  modem is set to follow DTR), before modem disconnects.
  677.          255     Modem send data out of buffer until completed or connection
  678.                  is lost.
  679. S40     Bit Mapped Option Status Codes
  680.         Bit(Dec)
  681.          0 (1)   MNP Extended Services (-Kn)
  682.                   0 Disable (-K0)
  683.                   1 Enable  (-K1)
  684.          1 (2)   Power Level Adj. for Cellular Use [)Mn]
  685.                   0 Auto Adj.  [)M0 default
  686.                   1 Force Adj. [)M1]
  687.          2 (4)   MNP Link negotiation speed (*Hn)
  688.                   0 At highest rate (*H0 default)
  689.                   1 At 1200 bps     (*H1)
  690.          3 (8), 4 (16), & 5 (32) Break Handling (\Kn)
  691.                 0,0,0 \K0
  692.                 1,0,0 \K1
  693.                 0,1,0 \K2
  694.                 1,1,0 \K3
  695.                 0,0,1 \K4
  696.                 1,0,1 \K5
  697.          6 (64) & 7 (128) MNP Block size (\An)
  698.                   0,0 64  (\A0)
  699.                   1,0 128 (\A1)
  700.                   0,1 196 (\A2)
  701.                   1,1 256 (\A3)
  702. S41     Bit Mapped Option Status Codes
  703.         Bit(Dec)
  704.          0 (1) & 1 (2) Compression Selection (%Cn)
  705.                   0,0 Disabled        (%C0)
  706.                   1,0 MNP 5           (%C1)
  707.                   0,1 V.42bis         (%C2)
  708.                   1,1 MNP 5 & V.42bis (%C3)
  709.          2 (4)   Auto Retrain (%En)
  710.                   0 Disable (%E0 default)
  711.                   1 Enable  (%E1)
  712.          3 (8)   Modem to Modem Flow Control (\Gn)
  713.                   0 Disable (\G0 default)
  714.                   1 Enable  (\G1)
  715.          4 (16)  Block mode control (\Ln)
  716.                   0 Stream (\L0 default)
  717.                   1 Block  (\L1)
  718.          5 (32)  Reserved
  719.          6 (64)  Reserved
  720.          7 (128) Reserved
  721. S46     Protocol Selection (136 or 138) (Affects v.42/v.42bis mode)
  722.          136     Disable Compression
  723.          138     Enable Compression (default)
  724. S48     v.42 Negotiation (0,7,128)
  725.          0       Disable Negotiation, proceed with LAPM
  726.          7       Enable Negotiation (default)
  727.          128     Disable Negotiation, fallback per S36 setting
  728. S80     Enhanced Features (Bit Mapped Options)
  729.          Bit (Decimal)
  730.          0 (1)   Enable Access to functions in bits 1-7 of S80
  731.          1 (2)   Sync Clock Source
  732.          2 (4)   Sync Clock source
  733.          3 (8)   DTR/DSR always on
  734.          4 (16)  Enable lease line mode (If hardware supports)
  735.          5 (32)  Enable V.25bis codes
  736.          6 (64)  Enable remote configuation
  737.          7 (128) Enable passwd/callback
  738. S82     LAPM Break Handling Options (3,7,128)
  739.          3       Expedited: Modem sends break immediately & data integrity is
  740.                          maintained before and after break.
  741.          7       Destructive: Modem sends break immediately & data being
  742.                          processed by each modem at that time is destroyed.
  743.          128     In sequence: Modem sends break in sequence with transmitted
  744.                          data & data integrity is maintained before and after
  745.                          the break
  746. S86     Report Connection Failure Cause Code
  747.          0      Normal disconnect
  748.          1-3    Undefined Error Code
  749.          4      Carrier loss
  750.          5      No error correction at other end
  751.          6      No response to feature negotiation
  752.          7      This modem is ASYNC only, other is SYNC
  753.          8      No framing technique in common
  754.          9      No protocol in common
  755.          10     Bad response to feature negotiation
  756.          11     No sync information from remote
  757.          12     Normal hangup initiated by remote
  758.          13     Retransmission limit reached
  759.          14     Protocol violation occured
  760.          15-255 Undefined Error Code
  761. S95     Extended Result Code Control (default sum is 0)
  762.          Each bit set high in this register enables the corresponding result
  763.          code regardless of the W command setting.
  764.         Bit (Decimal Value)
  765.          0 (1)   CONNECT XXXX result code gives DCE to DCE rate instead of
  766.                  local DTE to DCE rate.
  767.          1 (2)   Append /ARQ to verbose CONNECT result code if protocol is NONE
  768.          2 (4)   Enable CARRIER XXXX result code
  769.          3 (8)   Enable PROTOCOL XXXX result code
  770.          4 (16)  Undefined
  771.          5 (32)  Enable COMPRESSION result code
  772.          6 (64)  Undefined
  773.          7 (128) Undefined
  774. S109    v.32/v.32bis Negotiation Rate Selection (default sum is 62)
  775.          Each bit set high in this register enables the corresponding rate as
  776.          a valid rate to be used during rate negotiation.
  777.         Bit (Decimal Value)
  778.          0 (1)   Unused
  779.          1 (2)   4800 bps
  780.          2 (4)   7200 bps
  781.          3 (8)   9600 bps
  782.          4 (16)  12000 bps
  783.          5 (32)  14400 bps
  784.          6 (64)  Unused
  785.          7 (128) Unused
  786. S110    v.32/v.32bis Mode & Rate Negotiation Control
  787.          0       Normal v.32 mode (no v.32bis support)
  788.          1       Normal v.32bis mode
  789.          2       v.32bis mode with automatic rate renegotiation (default)
  790.          3       v.32bis mode with automatic rate renegotiation starting with
  791.                  the lowest rate set in S109 and working up one defined rate at
  792.                  a time toward the highest rate set in S109 (based on %Q level
  793.                  at each rate prior to stepping up.) (If the modem steps back
  794.                  down, it will also follow the S109 settings.)
  795. S202    Remote Access Escape Charactor (0-255, Default 170)
  796.  
  797. SCn=n   BUSY Detect Watermark Controls
  798.          Each register "pair" holds the value for each setting.  To set a value,
  799.          divide the setting by 256.  The integer goes in the second register,
  800.          while the remained goes in the first.  (A setting of 516 would convert
  801.          to 2 Remainder 4, and could be set by sending ATSC0=4SC1=2 to the
  802.          modem.)  Settings are in 1/100ths of a second.
  803.         Default values:
  804.          Minimum BUSY ON Time
  805.           SC0=30
  806.           SC1=0
  807.          Maximum BUSY ON Time
  808.           SC2=75
  809.           SC3=0
  810.          Minimum BUSY OFF Time
  811.           SC4=30
  812.           SC5=0
  813.          Maximum BUSY OFF Time
  814.           SC6=75
  815.           SC7=0
  816.          (Defaults support FCC Spec. BUSY signal.  Setting SC0=25 & SC4=25
  817.           allows FAST BUSY to also be detected as BUSY.)
  818. SC8=n   Set number of valid BUSY Pulses before reporting BUSY (4 is default)
  819.  
  820.  
  821. FAX commands of special interest to Supra Users:
  822.         +FAE=n  (CLASS 1 Only) Adaptive Answer / Silent Answer Mode Control
  823.                  0       Disable Both
  824.                  1       Adaptive Answer ONLY
  825.                  2       Adaptive Answer & Silent Answer
  826.                  3       Silent Answer ONLY
  827.         +FAA=n  (CLASS 2 Only) Adaptive Answer / Silent Answer Mode Control
  828.                  0       Disable Both
  829.                  1       Adaptive Answer ONLY
  830.                  2       Adaptive Answer & Silent Answer
  831.                  3       Silent Answer ONLY
  832.  
  833. Connection Result Codes:
  834.  
  835. Numeric Verbose
  836. 0       OK
  837. 1       CONNECT                 (300 bps)
  838. 2       RING
  839. 3       NO CARRIER
  840. 4       ERROR
  841. 5       CONNECT 1200
  842. 6       NO DIALTONE
  843. 7       BUSY
  844. 8       NO ANSWER
  845. 9       CONNECT 0600
  846. 10      CONNECT 2400
  847. 11      CONNECT 4800
  848. 12      CONNECT 9600
  849. 13      CONNECT 7200
  850. 14      CONNECT 12000
  851. 15      CONNECT 14400
  852. 16      CONNECT 19200
  853. 17      CONNECT 38400
  854. 18      CONNECT 57600
  855. 19      CONNECT 115200          (Not Currently Supported on MOST models)
  856. 22      CONNECT 1200/75         (Models with v.23 support only)
  857. 23      CONNECT 75/1200         (Models with v.23 support only)
  858.  
  859. 24      DELAYED
  860. 32      BLACKLISTED
  861. 33      FAX
  862. 35      DATA
  863.  
  864. 40      CARRIER 300
  865. 44      CARRIER 1200/75         (Models with v.23 support only)
  866. 45      CARRIER 75/1200         (Models with v.23 support only)
  867. 46      CARRIER 1200
  868. 47      CARRIER 2400
  869. 48      CARRIER 4800
  870. 49      CARRIER 7200
  871. 50      CARRIER 9600
  872. 51      CARRIER 12000
  873. 52      CARRIER 14400
  874.  
  875. 66      COMPRESSION: CLASS 5    (MNP 5)
  876. 67      COMPRESSION: V.42BIS    (BTLZ)
  877. 69      COMPRESSION: NONE
  878.  
  879. 70      PROTOCOL: NONE
  880. 77      PROTOCOL: LAP-M         (V.42)
  881. 80      PROTOCOL: ALT           (MNP)
  882. 81      PROTOCOL: ALT-CELLULAR  (MNP 10)
  883. +FC     +FCERROR
  884.  
  885. V.32 & V.32BIS EXTERNAL DISPLAY CODES
  886.  
  887. Red LED's
  888.  
  889.         OH      Off Hook
  890.         RD      Receiving Data
  891.         SD      Sending Data
  892.         TR      Terminal Ready (Follows DTR per &Dn setting)
  893.  
  894. Green LED Display PANEL
  895.  
  896.         AA      Auto Answer (RI displayed during ring)
  897.         CD      Carrier Detected
  898.         DC      Data Compression in use
  899.         DI      Dialing
  900.         FX      FAX MODE
  901.         LP      LAPM Error Correction in use.
  902.         M2      MNP2 Error Correction in use.
  903.         M3      MNP3 Error Correction in use.
  904.         M4      MNP4 Error Correction in use.
  905.         M5      MNP5 Data Compression in use.
  906.         OK      Modem Powered Up Correctly and Ready for Use.
  907.         RE      Receive Error while using LAPM or MNP mode.
  908.         RI      Ring Indicator
  909.         RT      Retrain in progress
  910.         TE      Transmit Error while using LPAM or MNP mode.
  911.         TM      Test Mode in use.
  912.         3       300 bps connection
  913.         12      1200 bps connection
  914.         24      2400 bps connection
  915.         48      4800 bps connection
  916.         72      7200 bps connection
  917.         96      9600 bps connection
  918.         120     12000 bps connection
  919.         144     14400 bps connection
  920.                                    
  921. Encoded Optional Feature List (ATi10)
  922.         Code    Feature                         Added AT Commands & Result Codes
  923.         101     Fax CLASS 1                     Normal CLASS 1 Command Set
  924.         104     Fax CLASS 2                     Normal CLASS 2 Command Set
  925.         105     Fax CLASS 2.0                   Normal CLASS 2.0 Command Set
  926.         115     CCITT v.17 (14.4 Fax)           See Above
  927.         120     Worldwide PSTN Support          %TTnn   PTT Cert. Test Signals
  928.                                                 *NC?    Display Country Config.
  929.                                                 *NCn    Change County Config.
  930.                                                 *Zn
  931.         121     CCITT v.23                      %Fn (1-3)
  932.                                                 %F1     75T/1200R
  933.                                                 %F2     1200R/75T
  934.                                                 %F3     v.23 HALF DUPLEX
  935.                                                 Adds These Result Codes:
  936.                                                 Numeric Verbose
  937.                                                 22      CONNECT 1200TX/75RX
  938.                                                 23      CONNECT 75TX/1200RX
  939.                                                 44      CARRIER 1200/75
  940.                                                 45      CARRIER 75/1200
  941.         122     CCITT v.25                      See Software Doc.s
  942.         123     Blacklisting                    *B      Display Blacklisted #'s
  943.                                                 *D      Display Delayed #'s
  944.                                                 Adds These Result Codes:
  945.                                                 24      DELAYED
  946.                                                 32      BLACKLISTED
  947.         124     Access Security                 *C      Enb. Sec. Acc. & Req.PW
  948.                                                 *E      Exit Sec. Access
  949.                                                 *L      List PW & CB directories
  950.                                                 *P      Stores PassWords
  951.                                                 *R      Request Sec. Acc. Mode
  952.         140     CCITT v.32bis (14.4 Data)       See Above
  953.         141     Silent Answer                   See Above
  954.         142     Caller ID                       See Above
  955.         143     MNP 10                          -B      Forced FB to 1200
  956.                                                 -C      MNP10 Sync Mode
  957.                                                 -C1     MNP10 Async Mode
  958.                                                 -C2     MNP 2
  959.                                                 -C3     MNP 3
  960.                                                 -K      No LAPM to MNP10 Conv.
  961.                                                 -K1     Conv. LAPM to MNP10
  962.                                                 -Q      FB to v.22/v.22bis
  963.                                                 -Q1     No FB to v.22/v.22bis
  964.                                                 -Un  Tx Level Change during FF
  965.                                                 -U0     auto attn to -10dBm
  966.                                                 -U1     auto attn to -18dBm
  967.                                                 -U2     auto attn to -22dBm
  968.                                                 -U3     auto attn to -25dBm
  969.                                                 -U4     Force 2400 to -10dBm
  970.                                                 -U5     Force 2400 to -18dBm
  971.                                                 -U6     Force 2400 to -22dBm
  972.                                                 -U7     Force 2400 to -25dBm
  973.                                                 )M      Tx fixed at -10dBm
  974.                                                 )M1     Tx attempt Tx < -10dBm
  975.                                                 *H0     Link Neg. at Top Speed
  976.                                                 *H1     Link Neg. at 1200
  977.                                                 *H2     Link Neg. at 4800
  978.         144     MNP "Cellular"
  979.         145     AutoSync
  980.         146     Enhanced Configuration Display  \S      Enhanced Display Codes
  981.         160     Voice Processing                In Upgrade Doc. for Option
  982.