  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. Recommendation R.20
  8.  
  9.        Replace by the following:
  10.  
  11.  
  12.               TELEGRAPH MODEM FOR SUBSCRIBER LINES
  13.  
  14.        (Geneva, 1980; amended at Malaga-Torremolinos, 1984
  15.                      and at Melbourne, 1988)
  16.  
  17.        The CCITT,
  18.  
  19. considering
  20.  
  21.        (a)  that the use of high-level telegraph transmission with  single  or
  22. double current may cause disturbing impulse noise in adjacent cable pairs that may 
  23. be eliminated by applying low-level transmission with telegraph modems;
  24.  
  25.        (b)   that  telegraph  modems  would  substantially  reduce  the  power
  26. consumption in the central office;
  27.  
  28.        (c)  that where connection to a subscriber has to be achieved over a non- 
  29. metallic pair (e.g., a voice-channel frequency-division multiplex or pulse code 
  30. modulation system) a telegraph modem has to be utilized;
  31.  
  32.        (d)  that the frequencies  given  below  are  already  standardized  in
  33. Recommendation V.21 [1];
  34.  
  35.        (e)  that suitable inexpensive telegraph modems can be  used  for  full
  36. duplex transmission on 2-wire circuits at modulation rates up to 300 bauds;
  37.  
  38. unanimously declares the view
  39.  
  40.        that where low-level telegraph transmission is used, the following method 
  41. of transmission should be recommended for all modulation rates up to 300 bauds.
  42.  
  43. 1.     Channel allocation
  44.  
  45.        The method of transmission is based on Recommendation V.21 [1] with the 
  46. following frequency designations:
  47.  
  48.        Central office to subscriber (channel 1) FA = 1 180 Hz,
  49.                                                   FZ =   980 Hz;
  50.  
  51.        Subscriber to central office (channel 2) FA = 1 850 Hz,
  52.                                                   FZ = 1 650 Hz.
  53.  
  54.        The characteristic frequencies as measured at the telegraph modem  line
  55. output should not differ by more than + 3 Hz from the nominal figures.
  56.  
  57.        The modem shall continue to operate with a + 6  Hz  change  in  receive
  58. frequency.
  59.  
  60.        It should be noted that there is equipment in use that applies alternative 
  61. frequencies to those shown in this Recommendation.
  62.  
  63. 2.     Interface
  64.  
  65.        Where the modem is  a  separate,  self-contained  unit,  the  following
  66. interchange circuits shall be used:
  67.  
  68.  
  69.  
  70.  
  71.  
  72.  
  73.  
  74.  
  75.  
  76.  
  77.  
  78.  
  79.        Common return (e.g. circuit 102 in Recommendation V.24 [2])
  80.  
  81.        Transmitted data (e.g. circuit 103 in Recommendation V.24 [2])
  82.  
  83.        Received data (e.g. circuit 104 in Recommendation V.24 [2])
  84.  
  85.        Carrier detect (e.g. circuit 109 in Recommendation V.24 [2]).1
  86.  
  87. 3.     Electrical characteristics
  88.  
  89.        The electrical characteristics (for stand alone telegraph modems) of the 
  90. interchange circuits, should be in accordance with CCITT Recommendation V.28 [3].
  91.  
  92. 4.     Performance
  93.  
  94. 4.1    The modem under test shall be connected to another modem (according  to
  95. this Recommendation or to Recommendation V.21) via an attenuator having a return 
  96. loss of 4 dB and  an  insertion  loss  of  30  dB.  The  relative  group-delay
  97. characteristics of the transmit filters are subject to further study.
  98.  
  99. 4.2    Uniform spectrum Gaussian noise (band limited to 10 kHz) shall be added to 
  100. give a normalized signal-to-noise ratio of 32 dB.
  101.  
  102.        This is defined as:
  103.  
  104.             SIGNAL ENERGY PER BIT = SIGNAL POWER x NOISE BANDWIDTH = 32 dB
  105.             NOISE POWER PER HERTZ   NOISE POWER    SIGNAL BIT RATE
  106.  
  107.  
  108.  
  109.         
  110.  
  111. 1 This is considered optional, particularly at the subscriber's location.
  112.  
  113. 4.3    Test signals to Recommendation R.51bis (QKS) shall be sent at a -13 dBm 
  114. transmit level in both directions simultaneously. (To ensure incoherence, the rate 
  115. of the test signals for the direction not under test shall be slightly lower.) The 
  116. test period shall be 15 seconds.
  117.  
  118.        The performance shall be in accordance with Table 1/R.20.
  119.  
  120.                                  TABLE 1/R.20
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.  
  128.  
  129.  
  130.  
  131.  
  132.  
  133.  
  134.  
  135.  
  136. 4.4    In certain configurations, it  is  not  possible  to  check  the  modem
  137. distortion, e.g. telegraph terminals, multiplex and switching  equipment  with
  138. integral telegraph modems on which the d.c. signal output of the telegraph modem 
  139. is inaccessible for any reason. The performance will normally be in the form of a 
  140.  
  141.  
  142.  
  143.  
  144.  
  145.  
  146. test for distortion margin before errors are output from the equipment.
  147.  
  148. Note - The modem need only be tested at the maximum  modulation  rate  of  the
  149. equipment into which it is to be incorporated.
  150.  
  151. 4.5    The design of the telegraph modem shall be such that  the  transmission
  152. performance is guaranteed without adjustment on installation or subsequently.
  153.  
  154. 5.     Line signal levels and terminating impedance
  155.  
  156.        The line interface of the modem shall be balanced and shall present  an
  157. impedance of 600 ohms with a return loss (reference 600 ohms resistive) of not 
  158. less than 14 dB (reflection coefficient no greater than 20%) over the range
  159. 300 - 3 400 Hz.
  160.  
  161. 5.1    Output signal level
  162.  
  163. 5.1.1  When terminated in 600 ohms the output level should be set to -13 dBm
  164.  
  165. Note - In certain applications, in particular if carrier  circuits  for  voice
  166. channel frequency division multiplex or pulse code modulation systems are used 
  167. (where the input level should be limited to -13 dBmO) it may be necessary to have 
  168. a setting range of output level which could give up to 0 dBm.
  169.  
  170. 5.1.2  The difference in output levels between the Binary 1 (condition Z)  and
  171. Binary 0 (condition A) signals shall not be greater than 1 dB for either of the 
  172. channels.
  173.  
  174. 5.2    Receive signal level
  175.  
  176. 5.2.1  When the received signal level is -43 dBm or greater, the equipment should 
  177. correctly interpret the line condition as either Fa or Fz.
  178.  
  179. 5.2.2  When the received signal level remains below a threshold between
  180. -45 dBm and -48 dBm, the equipment shall ignore incoming information within 300 ms 
  181. of the signal level dropping below the threshold. During this delay the receiving 
  182. equipment may interpret (correctly or incorrectly) characters received after the 
  183. drop in received signal level below the threshold. Thereafter,  the  equipment
  184. should not interpret characters received until the received signal  level  has
  185. restored to at least 2 dB above the threshold. If the signal level drops below the 
  186. threshold for less than 10 ms, the equipment should take no action.
  187.  
  188. 5.2.3  Once the received signal level has fallen below the threshold value, the 
  189. equipment shall ignore any subsequent increases in the signal level which  are
  190. either less than 2 dB above the threshold or of more than 2 dB above the threshold 
  191. but less than 10 ms in duration.
  192.  
  193. Note 1- The requirements of 5.2.3 need not apply during the first 20 ms from the fall 
  194. in received signal level below the threshold.
  195.  
  196. Note 2 - The signal level detector shall respond to the total power contained within 
  197. the nominal spectrum of the received line signal.
  198.  
  199.  
  200.  
  201.  
  202. 6.     Maintenance facilities
  203.  
  204.        Maintenance facilities, e.g. test loops, are a national matter.
  205.  
  206. 7.     Protection against high voltages
  207.  
  208.  
  209.  
  210.  
  211.  
  212.  
  213.  
  214.  
  215.  
  216.  
  217.  
  218.  
  219.        The equipment shall withstand residual lightning surges, high voltage  line
  220. faults, and high level telegraph keying. The protection required is  considered  a
  221. national matter, though in some cases Recommendation K.y could be applied [3].
  222.  
  223. 8.     Line wetting
  224.  
  225. 8.1    Line wetting, where required by the type of line plant used, will normally be 
  226. sourced by the in-station equipment and looped by the subscriber's equipment.
  227.  
  228. 8.2    The current has a maximum value of 15 mA with the line short-circuited.  The 
  229. wetting current shall be a minimum of 5 mA on 4000 ohms lines.  The  open  circuit
  230. voltage shall be under 80 V.
  231.  
  232. Note - In some countries, other values may apply.
  233.  
  234.        Where a modem may be required to work in the presence of line wetting, then 
  235. the modem performance ( 4) and the modem line impedance ( 5) requirements must apply 
  236. with line wetting current flowing.
  237.  
  238.        The noise applied to the line from the wetting power supply shall be under  - 
  239. 80 dBm (600 ohms) over a range 300 to 3 400 Hz (flat).
  240.  
  241. 9.     Permitted out-of band energy
  242.  
  243. 9.1    The out-of-band  energy  is  a  national  matter;  however,  the  following
  244. information is provided to assist equipment manufacturers.
  245.  
  246. 9.2    The transmitted signal level (with an output level at -13 dBm) at  any  one
  247. frequency shall not exceed the following limits (with the forward and reverse channel 
  248. keyed at 300 bit/s with a QKS code):
  249.  
  250.        200 Hz to 3 200 Hz                          -13 dBm
  251.        100 Hz to 200 Hz and 3 200 Hz to 3 400 Hz   -23 dBm
  252.        Below 100 Hz                                -33 dBm
  253.        Above 3 400 Hz                              -33 dBm  and  decreasing
  254.                                                       by 12 dB/octave to
  255.                                                      -67 dBm.
  256.  
  257.                                 REFERENCES
  258.  
  259. [1]  CCITT Recommendation - 300 bit/s per second duplex modem  standardized  for
  260.      use in the general switched telephone network, Recommendation V.21.
  261.  
  262. [2]  CCITT Recommendation - List of definitions for interchange circuits between 
  263.      data  terminal  equipment   adn   data   circuit   terminating   equipment,
  264.      Recommendation V.24.  
  265.  
  266. [3]  CCITT Recommendation - Electrical characteristics for unbalances double-
  267.      current interchange circuits, Recommendation V.28,  
  268. [4]  CCITT Recommendation - Resistibility of  subscribers'  terminals  to  over-
  269.      voltages and over-currents, Recommendation K.y.
  270.